• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 171
  • 9
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 193
  • 193
  • 193
  • 170
  • 152
  • 71
  • 68
  • 62
  • 61
  • 51
  • 48
  • 38
  • 37
  • 33
  • 32
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Resistência de união de cimentos resinosos, convencional e autoadesivo, em substratos dentinários normal e hipermineralizado artificalmente / Bond strength of resin, conventional and self-adhesive cements, under normal dentin substrates and sclerotic artificially

Tavares, Maria Tereza Gomes [UNESP] 21 March 2016 (has links)
Submitted by MARIA TEREZA GOMES TAVARES null (mariatereza_t@hotmail.com) on 2016-04-04T12:44:42Z No. of bitstreams: 1 Dissertação Maria Tereza.pdf: 2059134 bytes, checksum: 54c1a762e9d937d867d45018734397ae (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-04-05T18:59:26Z (GMT) No. of bitstreams: 1 tavares_mtg_me_arafo.pdf: 2059134 bytes, checksum: 54c1a762e9d937d867d45018734397ae (MD5) / Made available in DSpace on 2016-04-05T18:59:27Z (GMT). No. of bitstreams: 1 tavares_mtg_me_arafo.pdf: 2059134 bytes, checksum: 54c1a762e9d937d867d45018734397ae (MD5) Previous issue date: 2016-03-21 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste trabalho foi avaliar a resistência de união de cimentos resinosos, convencional e autoadesivo, em um substrato dentinário normal e hipermineralizado artificialmente. Sessenta e seis (N=67) molares humanos hígidos, doados pelo Banco de Dentes da Faculdade de Odontologia de Araraquara, foram selecionados e divididos aleatoriamente, de acordo com o tipo de substrato dentinário: normal (n= 33) e hipermineralizado artificialmente (n=34). Em seguida o grupo de substrato dentinário normal foi subdividido em N-ARC, N-U200 e N-AC+U200 de acordo com o tipo de protocolo de cimentação: RelyX™ ARC, RelyX™ U200 e condicionamento adicional com ácido fosfórico 37% por 15” + RelyX™ U200; e o de substrato hipermineralizado artificialmente foi subdividido em H-ARC, H-U200 e H-AC+U200 seguindo o mesmo protocolo de cimentação. Um (n=1) espécime de cada grupo foi submetido a análise de microscopia eletrônica de varredura (MEV). As cimentações dos cilindros foram realizadas com a ajuda de uma matriz bipartida de teflon. Após período de armazenagem em ambiente úmido por 24 horas a 37°C, os espécimes foram adaptados a um dispositivo para o teste de resistência de união ao microcisalhamento. A análise estatística utilizada foi Two-way ANOVA/Tukey. Não foram encontradas diferença estatística entre os substratos dentinários e os protocolos de cimentação. O cimento resinoso RelyX ARC apresentou maiores valores de resistência de união (N-ARC=77,60 e H-ARC=68,40), independente do substrato. O padrão de fratura predominante foi do tipo adesiva. As imagens de microscopia mostraram que os cimento autoadesivo RelyX U200 é incapaz de formar camada híbrida. Conclui-se que o cimento autoadesivo apresenta resistência de união ao microcisalhamento semelhante ao cimento convencional, independente do substrato dentinário ser normal ou hipermineralizado artificialmente. / The objective of this study was to evaluate the bond strength of resin, conventional and self-adhesive cements, in a normal dentin and sclerotic artificially. Sixty-six (N = 66) human molars, donated by Teeth Bank of Araraquara Dental School, were selected and randomly divided according to the type of dentin: normal (n = 33) and sclerotic artificially (n = 33). Then normal dentin group was subdivided into N ARC, N-U200 and N-AC + U200 in accordance with the type of cementing protocol: RelyX ™ ARC RelyX ™ U200 and additional conditioning with phosphoric acid 37% by 15 "+ RelyX ™ U200; and the sclerotic substrate was artificially subdivided into M-ARC M-H U200 and U200 AC + following the same protocol cementing. A (n = 1) specimen from each group was subjected to analysis of scanning electron microscopy (SEM). The cementing was carried out with the aid of a metallic mold Teflon. After the storage period in a humid environment for 24 hours at 37 ° C, the specimens were adapted to a device for testing the bond strength of the microshear. The statistical analysis used was Two-way ANOVA / Tukey. There were no statistical difference between the dentinal substrates and cementation protocols. The resin cement RelyX ARC showed higher bond strength values (N = 77.60 ARC and ARC-H = 68.40), regardless of the substrate. The pattern of prevalent fracture was of adhesive type of cement and dentin. The microscopy images showed that the selfadhesive cement RelyX U200 is unable to form hybrid layer. It follows that the selfadhesive cement bond strength has to microshear similar to conventional cement, independent of the substrate normal or sclerotic dentin be artificially.
52

Avaliação da resistência de união à tração e espessura de camada híbrida : influência de sistemas adesivos e condições de substrato dentinário

Susin, Alexandre Henrique [UNESP] 08 October 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:27Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-10-08Bitstream added on 2014-06-13T19:01:43Z : No. of bitstreams: 1 susin_ah_dr_arafo.pdf: 3155550 bytes, checksum: 3c18f1511d8950d04d4fb3ead12080d0 (MD5) / O objetivo deste trabalho foi realizar, in vitro, avaliação da resistência de união à tração (RUT) e espessura de camada híbrida (ECH), em diferentes condições de substrato dentinário (úmido, S1; desidratado, S2 e reumedecido, S3), proporcionado pelos sistemas adesivos de 4ª geração, Scotchbond Multi Uso (SBMU) - 3M ESPE; Single Bond (SB) - 3M ESPE; Prime & Bond 2.1 (P&B2.1) - Dentsply e One Coat Bond (OCB) - Coltène-Whaledent, e os sistemas adesivos de 5ª geração (autocondicionantes), Clearfil SE Bond (CSEB) - Kuraray e One Up Bond F (OUBF) - Tokuyama. Foram utilizados 180 dentes seccionados na altura do 1/3 médio da coroa, originando duas partes cada um: remanescente dental (utilizado no teste de resistência de união à tração) e fragmento oclusal (utilizado na mensuração de camada híbrida). Para cada um dos 18 grupos foram realizadas 10 repetições em cada um dos dois testes, perfazendo um total de 360 amostras. O teste de RUT, foi realizado na Máquina de Ensaios Mecânicos MTS-810, em velocidade de 2 mm / min., e a ECH, foi mensurada à partir de fotografias obtidas em microscopia eletrônica de varredura (Microscópio Eletrônico JSM 330 A), com o software Image Tool 2.00. No teste de RUT, o desempenho dos sistemas adesivos foi melhor em S1 e, dentre eles, o CSEB foi o que apresentou a maior média, 23,01 MPa, enquanto que a menor, foi apresentada pelo OUBF, 15,69 MPa. Os sistemas adesivos de 4ª geração apresentaram médias intermediárias, às quais não foi possível encontrar diferenças estatisticamente significantes. (SBMU, 18,71 MPa; SB, 19,43 MPa; P&B2.1, 17,45 MPa e OCB, 19,92 MPa). As menores médias de RUT dos sistemas adesivos de 4ª geração, foram constatadas em S2, apresentando a menor média para o SB, 6,64 MPa, enquanto que os sistemas autocondicionantes, apresentaram menores variações de RUT entre os... . / The aim of this work was to perform the evaluation of the tensile bond strength (TBS) and the thickness of the hybrid layer (THL), in different conditions of dentinal substrate (moist, S1; dehydrated, S2 and remoistened, S3), provided by the fourth generation adhesive systems, Scotchbond Multi Uso (SBMU) - 3M ESPE; Single Bond (SB) - 3M ESPE; Prime & Bond 2.1 (P&B2.1) - Dentsply and One Coat Bond (OCB) - Coltène-Whaledent, and the fifth generation adhesive systems (self-etching), Clearfil SE Bond (CSEB) - Kuraray and One Up Bond F - Tokuyama. One hundred and eighty teeth bisected in the 1/3 crown mean level were used, originating two parts each: dental remnant (used in the tensile bond strength testing) and occlusal fragment (used in the hybrid layer measurement). For each of the 18 groups, 10 repetitions were performed for both tests, in a total of 360 samples. The TBS test was performed in a Mechanic Testing Machine MTS-810, in speed 2 mm/ min, and the THL was measured from photographs obtained in scanning electron microscopy (Electron Microscope JSM 330 A), using a software Image Tool 2.00. During the TBS test, the performance of the adhesive systems was better in S1 and, among themselves, CSEB presented the higher average, 23,01 MPa, while the lower average was presented by OUBF, 15,69 MPa. The fourth generation adhesive systems presented intermediate averages, those which did not revealed statistically significant differences. (SBMU, 18,71 MPa; SB, 19,43 MPa; P&B2,1, 17,45 MPa and OCB, 19,92 MPa). The lower averages of the fourth generation adhesive systems in TBS were verified in S2, presenting the lower average for SB, 6,64 MPa, while the self-etching systems presented lower TBS variations among the different substrates. In the THL results, lower variability was verified among the average results obtained, being the higher average presented by SBMU, 4,80 æm... (Complete abstract, click electronic address below).
53

Análise in vitro da resistência de união ao cisalhamento de uma resina composta à dentina humana e à bovina, tratadas com diferentes adesivos

Magnani, Cristina [UNESP] January 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:27Z (GMT). No. of bitstreams: 0 Previous issue date: 2006Bitstream added on 2014-06-13T20:22:10Z : No. of bitstreams: 1 magnani_c_dr_arafo.pdf: 594008 bytes, checksum: d8496d3440da8bb7f9fe9acf656211c7 (MD5) / O presente trabalho teve por objetivo avaliar, comparativamente, in vitro, a resistência de união ao cisalhamento de uma resina composta à dentina humana e à dentina bovina, submetidas ao tratamento com dois sistemas adesivos convencionais simplificados (Prime Bond NT®, Dentsply e Single Bond®/3M) e dois sistemas adesivos autocondicionantes (AdheSE®/Ivoclar-Vivadent e Adpper Prompt-L-Pop®/ 3M). Para a confecção dos corpos-de-prova, foram utilizadas as superfícies vestibulares de 40 dentes molares humanos e de 40 dentes incisivos bovinos, as quais foram divididas aleatoriamente em 8 grupos de 10 amostras cada, de acordo com o tipo de substrato e o sistema adesivo utilizado: Grupo 1 - dentina humana tratada com o sistema adesivo Single Bond; Grupo 2 - dentina humana tratada com o sistema adesivo Prime Bond NT; Grupo 3 - dentina humana tratada com o sistema adesivo AdheSE; Grupo 4 - dentina humana tratada com o sistema adesivo Adpper Prompt-L-Pop; Grupo 5 - dentina bovina tratada com o sistema adesivo Single Bond; Grupo 6 - dentina bovina tratada com o sistema adesivo Prime Bond NT; Grupo 7 - dentina bovina tratada com o sistema adesivo AdheSE; Grupo 8 - dentina bovina tratada com o sistema adesivo Adpper Prompt-L-Pop. Após o tratamento das superfícies, com o auxílio de uma matriz bipartida, foram confeccionados cilindros de resina composta Tetric Ceram apresentando 3mm de diâmetro e 4mm de altura. Os corpos-de-prova foram então armazenados em água destilada a 37ºC por 24 horas e submetidos a termociclagem (550 ciclos à temperatura de 10ºC e 55ºC). Após 48 horas de armazenamento em água destilada a 37ºC, foram levados a uma Máquina de Teste Universal para a realização do teste de cisalhamento utilizando-se uma ponta em forma de cinzel e velocidade do atuador de 0,5 mm/min. Os tipos de fratura foram analisados em lupa estereoscópica com 40X de aumento. / The purpose of this in vitro study was to evaluate, comparatively, the shear bond strength of a composite resin to human and bovine dentin treated with two conventional simplified adhesive systems (Prime Bond NT®/Dentsply and Single Bond®/3M) and two self-etching adhesive systems (AdheSE®/Ivoclar-Vivadent and Adpper Prompt-L-Pop®/3M). For preparation of specimens, the buccal surface of 40 human molars and 40 bovine incisors were obtained and randomly assigned to 8 groups (n=10), according to the type of substrate and adhesive system used. Group1 - human dentin treated with Single Bond; Group 2 - human dentin treated with Prime Bond NT; Group 3 - human dentin treated with AdheSE; Group 4 - human dentin treated with Adpper Prompt-L-Pop; Group 5 - bovine dentin treated with Single Bond; Group 6 - bovine dentin treated with Prime Bond NT; Group 7 - bovine dentin treated with AdheSE; Group 8 - bovine dentin treated with Adpper Prompt-L-Pop. After treatment with the adhesive systems, composite resin (Tetric Ceram) cylinders (3 mm in diameter and 4 mm high) were fabricated using a split matrix and were bonded to the dentin surfaces. The specimens were stored in distilled water at 37ºC for 24 hours and then submitted to a thermocycling regimen (550 cycles between 10ºC and 55ºC). After 48-hour storage in distilled water at 37ºC, the specimens were taken to a universal testing machine and loaded in shear strength until failure using knife-edge-shearing blade running at a crosshead speed of 0.5 mm/min. Failure mode was analyzed using a stereomicroscope at X40. Data were submitted to statistical analysis by analysis of variance at 5% significance level. The results showed that Single Bond and Prime Bond NT adhesive systems presented similar shear bond strength to each other (p>0.05) and significantly higher means than AdheSE and Adper Prompt-L-Pop (p<0.05), regardless of the type of substrate.
54

Avaliação da resistência de união à tração e espessura de camada híbrida : influência de sistemas adesivos e condições de substrato dentinário /

Susin, Alexandre Henrique January 2002 (has links)
Orientador : Osmir Batista de Oliveira Júnior / Banca: José Roberto Cury Saad / Banca: Maria Salete Machado Cândido / Banca: Edson Alves de Campos / Banca: Denise Pedrini / Resumo: O objetivo deste trabalho foi realizar, in vitro, avaliação da resistência de união à tração (RUT) e espessura de camada híbrida (ECH), em diferentes condições de substrato dentinário (úmido, S1; desidratado, S2 e reumedecido, S3), proporcionado pelos sistemas adesivos de 4ª geração, Scotchbond Multi Uso (SBMU) - 3M ESPE; Single Bond (SB) - 3M ESPE; Prime & Bond 2.1 (P&B2.1) - Dentsply e One Coat Bond (OCB) - Coltène-Whaledent, e os sistemas adesivos de 5ª geração (autocondicionantes), Clearfil SE Bond (CSEB) - Kuraray e One Up Bond F (OUBF) - Tokuyama. Foram utilizados 180 dentes seccionados na altura do 1/3 médio da coroa, originando duas partes cada um: remanescente dental (utilizado no teste de resistência de união à tração) e fragmento oclusal (utilizado na mensuração de camada híbrida). Para cada um dos 18 grupos foram realizadas 10 repetições em cada um dos dois testes, perfazendo um total de 360 amostras. O teste de RUT, foi realizado na Máquina de Ensaios Mecânicos MTS-810, em velocidade de 2 mm / min., e a ECH, foi mensurada à partir de fotografias obtidas em microscopia eletrônica de varredura (Microscópio Eletrônico JSM 330 A), com o software Image Tool 2.00. No teste de RUT, o desempenho dos sistemas adesivos foi melhor em S1 e, dentre eles, o CSEB foi o que apresentou a maior média, 23,01 MPa, enquanto que a menor, foi apresentada pelo OUBF, 15,69 MPa. Os sistemas adesivos de 4ª geração apresentaram médias intermediárias, às quais não foi possível encontrar diferenças estatisticamente significantes. (SBMU, 18,71 MPa; SB, 19,43 MPa; P&B2.1, 17,45 MPa e OCB, 19,92 MPa). As menores médias de RUT dos sistemas adesivos de 4ª geração, foram constatadas em S2, apresentando a menor média para o SB, 6,64 MPa, enquanto que os sistemas autocondicionantes, apresentaram menores variações de RUT entre os... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The aim of this work was to perform the evaluation of the tensile bond strength (TBS) and the thickness of the hybrid layer (THL), in different conditions of dentinal substrate (moist, S1; dehydrated, S2 and remoistened, S3), provided by the fourth generation adhesive systems, Scotchbond Multi Uso (SBMU) - 3M ESPE; Single Bond (SB) - 3M ESPE; Prime & Bond 2.1 (P&B2.1) - Dentsply and One Coat Bond (OCB) - Coltène-Whaledent, and the fifth generation adhesive systems (self-etching), Clearfil SE Bond (CSEB) - Kuraray and One Up Bond F - Tokuyama. One hundred and eighty teeth bisected in the 1/3 crown mean level were used, originating two parts each: dental remnant (used in the tensile bond strength testing) and occlusal fragment (used in the hybrid layer measurement). For each of the 18 groups, 10 repetitions were performed for both tests, in a total of 360 samples. The TBS test was performed in a Mechanic Testing Machine MTS-810, in speed 2 mm/ min, and the THL was measured from photographs obtained in scanning electron microscopy (Electron Microscope JSM 330 A), using a software Image Tool 2.00. During the TBS test, the performance of the adhesive systems was better in S1 and, among themselves, CSEB presented the higher average, 23,01 MPa, while the lower average was presented by OUBF, 15,69 MPa. The fourth generation adhesive systems presented intermediate averages, those which did not revealed statistically significant differences. (SBMU, 18,71 MPa; SB, 19,43 MPa; P&B2,1, 17,45 MPa and OCB, 19,92 MPa). The lower averages of the fourth generation adhesive systems in TBS were verified in S2, presenting the lower average for SB, 6,64 MPa, while the self-etching systems presented lower TBS variations among the different substrates. In the THL results, lower variability was verified among the average results obtained, being the higher average presented by SBMU, 4,80 æm... (Complete abstract, click electronic address below). / Doutor
55

Atividade antibacteriana de sistemas adesivos dentinários autocondicionantes sobre bactérias cariogênicas

Gondim, Juliana Oliveira [UNESP] 30 November 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:47Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-11-30Bitstream added on 2014-06-13T19:56:38Z : No. of bitstreams: 1 gondim_jo_me_arafo.pdf: 487270 bytes, checksum: 789b8f434824d723680740b007e8975b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A incorporação de agentes antibacterianos aos sistemas adesivos dentinários autocondicionantes tem sido proposta com o intuito de eliminar bactérias residuais presentes na dentina, prevenindo, assim, a recorrência de cárie. O presente trabalho teve como objetivo avaliar a atividade antibacteriana dos sistemas adesivos dentinários autocondicionantes: Clearfil Protect Bond (CPB), Clearfil SE Bond (CSEB), Xeno III (XIII) e Clearfil Tri-S Bond (C3SB), com e sem fotoativação, sobre bactérias cariogênicas, bem como a influência da dentina humana na atividade antibacteriana destes sistemas adesivos, utilizando o método de difusão em ágar. A solução de digluconato de clorexidina a 0,2% foi utilizada como controle positivo. O componente adesivo do CPB e do CSEB, o líquido A do XIII e o C3SB não apresentaram atividade antibacteriana quando aplicados sobre discos de papel. O conjunto primer e adesivo do CPB não fotoativado promoveu a maior inibição contra S. mutans (p<0,05), enquanto que com a fotoativação, não houve diferença entre esses componentes juntos e o primer isoladamente. Para o L. acidophillus, o primer do CPB apresentou a maior atividade antibacteriana nas duas condições de fotoativação (p<0,05). Quando os materiais foram aplicados sobre discos de dentina, somente a CHX promoveu efeito inibitório, o qual foi de menor intensidade do que quando aplicada sobre discos de papel (p<0,05). A CHX apresentou maior atividade antibacteriana sobre S. mutans quando comparado com L. acidophillus (p<0,05). Pode-se observar que a fotoativação reduziu significantemente a 18 atividade antibacteriana dos sistemas adesivos autocondicionantes, que a presença do MDPB no sistema adesivo dentinário é importante para a atividade antibacteriana sobre bactérias cariogênicas, e que a dentina atua como barreira de proteção eliminando ou reduzindo a ação antibacteriana de materiais odontológicos. / The incorporation of antibacterial agents in self-etching dentin bonding systems has been introduced in attempts to eliminate dentin residual bacteria, preventing secondary caries. Therefore, the aim of this study was to evaluate the antibacterial activity of cured and uncured self-etching dentin bonding systems Clearfil Protect Bond (CPB), Clearfil SE Bond (CSEB), Xeno III (XIII) and Clearfil Tri-S Bond (C3SB), against S. mutans and L. acidophillus, by the agar disc-diffusion test, as well as to evaluate the influence of human dentin on their antibacterial activity. A 0.2% aqueous solution of chlorhexidine (CHX) was used as a positive control. CPB and CSEB bond component, liquid A of Xeno III and C3SB did not show any antibacterial activity when applied onto paper discs. The primer and bond set of uncured CPB presented the strongest inhibitory activity against S. mutans (p<0.05), however after light-activation, no difference was observed between these components together and when primer was applied individually. Independently of light-activation conditions, CPB primer showed the strongest antibacterial activity against L. acidophillus (p>0.05). When the materials were applied onto dentin discs, only CHX presented inhibitory activity, which was less intense than when it was applied onto paper discs (p<0.05). CHX showed stronger antibacterial activity against S. mutans than against L. acidophillus (p<0.05). In conclusion, light-activation significantly reduced the antibacterial activity, the presence of MDPB in adhesive systems is important to the inhibitory effect against cariogênico 20 bacteria, and the dentin acted as a protection barrier reducing or inhibiting the antibacterial activity of dental materials.
56

Influência de uma substância antioxidante na união de materiais resinosos à dentina após a realização de clareamento

Toseto, Roberta Mariano [UNESP] 11 June 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-06-11Bitstream added on 2014-06-13T20:31:06Z : No. of bitstreams: 1 toseto_rm_me_araca.pdf: 538183 bytes, checksum: 66c14e3d1e29de028537c8e3fbfe3bab (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo analisou a influência do ascorbato de sódio 10% (AS) na formação de tags e camada híbrida em dentina após clareamento dental. Materiais e métodos: Foram testados 6 grupos. GI- Controle: somente restaurações de Resina Composta (RC); GII- Ascorbato de Sódio (AS) + RC; GIII- clareamento com peróxido de carbamida 10% (PC) + RC; GIV- PC + AS + RC; GV- clareamento com peróxido de hidrogênio 35% (PH) + RC; GVI– PH + AS + RC. Após os tratamentos, os dentes foram seccionados e descalcificados. Os cortes foram montados em lâminas de vidro e corados pelo método Brown & Brenn. A análise em microscopia óptica comum (Axiophot) em 400X, evidenciou os tags e camada híbrida formados. Resultados: Os dados foram tabulados, sendo obtidas as respectivas médias para comprimento dos tags e a espessura da camada híbrida: GI- 10 e 3.1μm, GII- 9.2 e 2.4 μm, GIII- 5.4 e 1.5 μm, GIV- 6.8 e 2.1 μm, GV- 5.7 e 1.6 μm, GVI- 7.1 e 2.1 μm. Conclusão: O clareamento dental com PC ou PH prejudica a formação de tags resinosos e camada híbrida. O uso do AS aumentou o comprimento destas estruturas / This study analyzed the influence of 10% sodium ascorbate (SA) on tag and hybrid layer formation in dentin after bleaching. Materials and Methods: Six groups were tested: GI- Control: restoration; GII- Sodium Ascorbate (SA) + restoration; GIII- Bleaching with carbamide peroxide (CP) + restoration; GIV- bleaching with CP + SA+ restoration; GV- bleaching with 35% hydrogen peroxide (HP) + restoration; and GVI- HP + SA + restoration. After treatments, the teeth were sectioned and decalcified. The length of resin tags and thickness of the hybrid layer were analyzed using optical microscopy (Axiophot). Results: The following results were obtained for the groups: GI- 10 and 3.1 μm, GII- 9.2 and 2.4 μm, GIII- 5.4 and 1.5 μm, GIV- 6.8 and 2.1 μm, GV–5.7 and 1.6 μm, GVI-7.1 and 2.1 μm (length of resin tags and thickness of the hybrid layer, respectively). Conclusion: Dental bleaching with CP or HP impairs the formation of resin tags and hybrid layer. The use of SA increases these measures
57

Inter-relação do comprimento dos prolongamentos resinosos (tags) e da espessura da camada híbrida de adesão, com a resistência de união de sistemas adesivos ao tecido dentinário

Rahal, Vanessa [UNESP] 06 February 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-02-06Bitstream added on 2014-06-13T19:10:17Z : No. of bitstreams: 1 rahal_v_me_araca.pdf: 1283772 bytes, checksum: 8c48fcbb5450bb565918794bd4285d39 (MD5) / O objetivo deste estudo foi analisar a correlação da espessura da camada híbrida de adesão e do comprimento dos prolongamentos resinosos (tags), com a resistência de união em tecido dentinário hígido, de um sistema adesivo convencional e de outro autocondicionante. Após a realização “in vivo” dos procedimentos restauradores, os dentes foram extraídos e seccionados no sentido mésio/distal. Em uma secção dental foi realizada a análise microscópica dos prolongamentos resinosos e da camada híbrida de adesão. Para tanto, os espécimes foram descalcificados, incluídos em parafina e cortados a uma espessura de 6 μm. Os cortes foram corados pelo método Brown e Brenn, para posterior análise e mensuração em microscópio óptico comum Axiophot Zeiss em 1000× (Carl Zeiss Company - DSM-940 A, Oberkochen, Baden- Württemberg, Germany). O remanescente dental foi acoplado à cortadeira metalográfica ISOMET 1000 (Buehler, Lake Bluff, IL, USA), de forma a permitir a realização de secções transversais, destinados ao teste de microtração (Instron modelo 4411 - Instron Inc., Canton, MA, EUA), sendo tracionados a 0,5 mm/min até sua ruptura. A superfície fraturada foi classificada segundo o padrão de fratura após análise sob lupa estereoscópica Stemi SV 11 (Carl Zeiss Company - DSM-940 A, Oberkochen, Baden-Württemberg, Germany) em aumento de 40×. Os valores obtidos no teste de microtração, na análise dos tags e da camada híbrida correspondentes a cada espécime e grupo de estudo, foram submetidos à análise estatística, com a realização do teste de Correlação de Pearson, não sendo verificada correlação entre os valores de resistência de união e a espessura da camada híbrida e comprimento dos tags resinosos em nenhum dos sistemas adesivos estudados. / The purpose of this study was to evaluate the possibility of the correlation between the hybrid layer thickness, the resin tag length, and the resin bond strength of a conventional and a self-etching adhesive system into sound dentin tissue. After “in vivo” restorative procedures were performed, each specimen was extracted and sectioned in a mesiodistal direction. One of the dental sections was then analyzed on a light microscope where the hybrid layer thickness and resin tag length were measured. For this experiment, the specimens were decalcified, embedded in paraffin and serially sectioned at a thickness of 6 μm. The sections were subsequently stained using Brown and Brenn stain for posterior analysis and for the measurement of the hybrid layer thickness and the resin tag length on a Zeiss Axiophot light microscope at 1000× magnification (Carl Zeiss Company - DSM-940 A, Oberkochen, Baden- Württemberg, Germany). The other section was mounted onto a metallographic cutter ISOMET 1000 (Buehler, Lake Bluff, IL, USA) and was sectioned. A microtensile test was subsequently performed (Instron modelo 4411 - Instron Inc., Canton, MA, USA) with a crosshead speed of 0.5 mm/min. The fractured surfaces were analyzed and the fracture pattern was characterized using a stereoscopic magnifying glass Stemi SV 11 at a 40× magnification (Carl Zeiss Company - DSM-940 A, Oberkochen, Baden- Württemberg, Germany). The results were subjected to Pearson Correlation Test and verified that the hybrid layer thickness and the resin tag length did not correlate with the bond strength of the adhesives systems.
58

Resistência de união de um sistema adesivo irradiado com laser Nd:YAG em dentina tratada com laser de Er:YAG

Malta, Daniel Alexandre Menezes Pedrosa [UNESP] 27 March 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-03-27Bitstream added on 2014-06-13T19:51:20Z : No. of bitstreams: 1 malta_damp_me_arafo.pdf: 3852992 bytes, checksum: d55fbc5b212b5a71eaa602dda984e5e6 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / A proposta deste estudo foi avaliar por meio do teste de microtração a resistência de união de um sistema adesivo irradiado com laser de Nd:YAG em dentina preparada com laser de Er:YAG. Estudos prévios têm demonstrado que a irradiação com laser após a aplicação do sistema adesivo é eficiente em alcançar alta força de união à tensão e ao cisalhamento. O laser de Er:YAG (Twinlight, Fotona, Eslovênia) com fluência de 60 J/cm2 foi usado para o tratamento da dentina. A irradiação do adesivo foi realizada usando o laser de Nd:YAG (Twinlight, Fotona, Eslovênia) com fluência de 100 J/cm2. As restaurações foram executadas com Adper Single Bond 2/Z250 (3M/ESPE, EUA). Vinte terceiros molares recentemente extraídos e livres de cárie foram empregados. Os dentes foram divididos em quatro grupos experimentais (n = 5): (G1) grupo controle onde não houve irradiação; (G2) irradiação do sistema adesivo com laser de Nd:YAG; (G3) tratamento da dentina com laser de Er:YAG; (G4) tratamento da dentina com laser de Er:YAG mais irradiação do sistema adesivo com laser de Nd:YAG. Um dente de cada grupo foi preparado para avaliação da interface adesiva sob microscopia eletrônica de varredura (MEV). Adicionalmente foi realizada a análise do padrão de fraturas, resultante dos ensaios mecânicos, sob microscopia óptica digital. Os testes de microtração foram realizados em uma máquina de ensaios mecânicos com célula de carga de 1 kN a uma velocidade de 0,5 mm/min. A análise estatística (ANOVA e teste de Tukey), dos dados referentes aos ensaios mecânicos, evidenciaram diferença estatística significante entre os grupos G1 e G3, G1 e G4, G2 e G3, e G2 e G4 e semelhança entre os grupos G1 e G2, e G3 e G4. As fraturas adesivas foram predominantes em todos os grupos experimentais. / The purpose of this study was to verify through micro tensile bond test the bond strength of an adhesive system irradiated with Nd:YAG laser in dentine treated with Er:YAG laser. Previous studies had shown that laser irradiation after the application of an adhesive system is efficient in achieving higher shear bond and tensile bond strength. Er:YAG laser (Twinlight, Fotona, Slovenia) with fluency of the 60 J/cm2 was used for the treatment of the dentine. The irradiation of the adhesive was performed using the Nd:YAG laser (Twinlight, Fotona, Slovenia) with the fluency of the 100 J/cm2. Dental restorations were performed with Adper Single Bond 2/Z250 (3m/ESPE, USA). Twenty caries free extracted human third molars were used. The teeth were divided in four experimental groups (n = 5): (G1) control group where there was no irradiation; (G2) irradiation of the adhesive system with the Nd:YAG laser; (G3) treatment of the dentin with Er:YAG laser; (G4) treatment of the dentin with Er:YAG laser plus irradiation of the adhesive system with Nd:YAG laser. One tooth of each group was prepared for evaluation of adhesive interface under scanning electron microscopy (SEM). In addition was performed an evaluation of the bond failures under digital optic microscopy. The micro tensile bond tests were performed in a MTS universal testing machine with 1 kN load cell at cross-head speed 0,5 mm/min. The statistical analysis (ANOVA and Tukey test) showed difference significant statistics between the groups G1 and G3, G1 and G4, G2 and G3, and G2 and G4; and similarity between the groups G1 and G2, and G3 and G4. The adhesive failures were predominant in all experimental groups.
59

Avaliação da resistência de união de diferentes sistemas adesivos à dentina bovina: influência de agentes dessensibilizantes

Lima, Darlon Martins [UNESP] 23 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-23Bitstream added on 2014-06-13T19:51:24Z : No. of bitstreams: 1 lima_dm_me_arafo.pdf: 826526 bytes, checksum: ff1d690d6b0676f46d0b484cb8adef94 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste trabalho foi o de avaliar comparativamente in vitro, a resistência de união ao cisalhamento de uma resina composta à dentina bovina em função da combinação de três diferentes sistemas adesivos e de dois diferentes agentes dessensibilizantes. Foram utilizados os sistemas adesivos: Single Bond, Master Bond e Prime & Bond 2.1 e os seguintes agentes dessensibilizantes: o Oxagel e o G. H. F. Dessensibilizador. Para a confecção dos corpos de prova, 90 incisivos bovinos (n=10) foram utilizados, os quais tiveram suas superfícies vestibulares desgastadas, até a exposição dentinária, de tal forma que, a área de adesão padronizada, tivesse 4 mm de diâmetro. Após a realização dos tratamentos de superfície, onde os Grupos controle eram indicados apenas pela aplicação do sistema adesivo, e os Grupos experimentais, pela aplicação dos agentes dessensibilizantes testados após o condicionamento ácido, foram confeccionados cilindros de resina composta Z-100, com o auxílio de uma matriz bipartida. Os corpos-de-prova foram então armazenados em água destilada a 37°C por 24 horas, e submetidos em seguida ao ensaio de cisalhamento, a uma velocidade do atuador de 0,5 mm/min. Os resultados obtidos foram submetidos à análise de variância, e ao teste de Tukey, ao nível de 5% de significância. Observou-se que houve influência dos agentes dessensibilizantes, quando estes eram aplicados na dentina bovina e interagiam com os sistemas adesivos, sendo que o G. H. F. Dessensibilizador aumentou estatisticamente os valores de resistência de união do Single Bond, e do Prime & Bond 2.1, e o Oxagel não influenciou nos valores de resistência de união dos sistemas adesivos testados. / The objective of this work was it of evaluating in vitro comparatively , the shear bond strength of a resin composed to the bovine dentin in function of the combination of three different adhesive systems and of two different agents dessensitizers. The adhesive systems were used, to know: Single Bond, Master Bond and Prime & Bond 2.1 and the following agents dessensitizers: Oxagel and G. H. F. Desensitizer. For the making of the test bodies, 90 incisive bovine (n=10) they were used, which had its worn away vestibular surfaces, until the exhibition dentin, in such a way that, the area of standardized adhesion, had 4 diameter mm. After the accomplishment of the surface treatments, where the Groups control was just suitable for the application of the adhesive system, and the experimental Groups, for the application of the agents dessensitizers tested after the acid conditioning, cylinders of composed resin were made Z-100, with the aid of a bipartite matrix. The test bodies, they were stored then in water distilled for 37°C by 24 hours, and submitted soon after to the shear bond strength rehearsal, to a crosshead speed of 0,5 mm/min. The obtained results were submitted to the variance analysis, and to the test of Tukey, at the level of 5% of significance. It was observed that there was influence of the agents dessensitizers, when these were applied in the bovine dentin and interagiam with the adhesive systems, and G. H. F. Dessensitizer increased statistically the values of resistance of union of Single Bond, and of the it Prime & Bond 2.1, and Oxagel didn't influence in the values of resistance of union of the tested adhesive systems.
60

Avaliação da resistência adesiva à microtração após desproteinização da dentina. Efeito de diferentes sistemas adesivos

Farias, Caroline Leão Cordeiro de [UNESP] 07 December 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:09Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-12-07Bitstream added on 2014-06-13T18:51:45Z : No. of bitstreams: 1 farias_clc_me_arafo.pdf: 808344 bytes, checksum: 95ebf651344a3331fa67cd1e8c616f15 (MD5) / O objetivo deste trabalho foi avaliar, in vitro, os efeitos da desproteinização da dentina sobre a resistência de união de três diferentes sistemas adesivos. Para tal, 30 terceiros molares humanos hígidos foram seccionados transversalmente, por meio de disco diamantado, na união do terço médio com o terço oclusal e desgastados com discos de lixa de granulação 320 e 600 para completa exposição da superfície dentinária e padronização da smear layer. Em seguida, os dentes foram divididos aleatoriamente em 6 grupos (n=5), os quais receberam aplicação dos sistemas adesivos Prime & Bond 2.1 (Dentsply), Single Bond (3M) e Clearfil SE Bond (Kuraray) de acordo com as instruções dos fabricantes (Grupos 2, 4 e 6, respectivamente) ou após desproteinização da dentina com hipoclorito de sódio a 5% durante 2 minutos (Grupos 1, 3 e 5, respectivamente). Restaurações de resina composta Z100 foram confeccionadas, de forma incremental, sobre toda a superfície oclusal. Os dentes foram, então, seccionados com disco diamantado com a finalidade de obter amostras em forma de palitos de 1,0 l 0,2mm2 de área adesiva. Vinte e cinco amostras de cada grupo foram selecionadas e armazenadas por 24 horas em água destilada a temperatura de 37ºC. Em seguida, os testes de microtração foram realizados em Máquina Universal de Ensaios MTS, à velocidade do atuador de 0,5mm/min. Os resultados, analisados estatisticamente por meio de Análise de variância e Teste de Tukey (p<0,05), indicaram que a aplicação do NaOCl proporcionou redução da resistência adesiva para todos os grupos (G1- 29,16 l 3,98; G3- 23,06 l 4,87; G5- 26,71 l 5,10) quando comparados com os grupos controle (G2- 33,11 l 5,76; G4- 30,62 l 5,47; G6- 32,09 l 6,43). Em relação aos padrões de fratura, observou-se predominância de fraturas adesivas, sendo que estas, nos grupos onde a dentina foi... . / The aim of this study was to evaluate, in vitro, the influence of dentin deproteinization on microtensile bond strength of three different adhesive systems. Thirty freshly extracted human molars were transversely wetcut using a diamond disk in order to expose the oclusal dentin surface. The teeth were randomly divided into 6 groups (n=5) and the adhesive systems Prime & Bond 2.1 (Dentsply), Single Bond (3M) e Clearfil SE Bond (Kuraray) were applied according to the manufacturer's instruction (control groups: G2, G4 and G6) or after application of sodium hypochlorite 5% for 2 minutes (G1, G3 and G5). The teeth were restored with Z100 (3M) composite resin and the microtensile specimens, with a bonded area of 1,00l 0,2mm2, were prepared by a slow-speed diamond disk. Twenty-five specimens of each group were selected and stored in distilled-water at 37oC for 24 hours. The microtensile tests were performed in a MTS universal testing machine with a cross-head speed of 0,5mm/min. The results were statistically analyzed by ANOVA and Tukey's test (p=0,05). Sodium hypochlorite pre-treatment significantly decreased the microtensile bond strength values of all adhesive systems (G1- 29,16 l 3,98; G3- 23,06 l 4,87; G5- 26,71 l 5,10) compared to control groups (G2- 33,11 l 5,76; G4- 30,62 l 5,47; G6- 32,09 l 6,43). Analysis of the morphology of the failure pattern revealed that, for the control specimens, debonding had occurred in the composite/teeth interface and in specimens that were etched and deproteinized, debonding was characterized by resin failure through the wide bases of the tag extensions into dentinal tubules.

Page generated in 0.3912 seconds