• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • 1
  • 1
  • 1
  • Tagged with
  • 23
  • 11
  • 10
  • 10
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Síntese de blendas co-monoméricas radiopacas de aplicação odontológica

Collares, Fabrício Mezzomo January 2010 (has links)
A radiopacidade dos materiais restauradores deve permitir distinguí-los da estrutura dental. Os adesivos dentinários normalmente, não possuem radiopacidade satisfatória a qual pode ser buscada com o acréscimo de substâncias que apresentem essa característica. Entretanto, esses materiais não devem interferir negativamente nas propriedades do polímero formado. O objetivo deste estudo foi avaliar a influência da adição de substâncias radiopacificantes em uma resina adesiva experimental nas propriedades do polímero. Uma resina adesiva experimental foi formulada com 50 % de Bis- GMA, 25 % TEGDMA, e 25 % HEMA, em peso, acrescido de Canforoquinona e EDAB (1% /mol). Para formar os grupos experimentais seis substâncias foram adicionadas à resina base: dióxido de titânio, óxido de bismuto, sulfato de bário, quartzo, dióxido de zircônio e trifluoreto de itérbio, em diferentes concentrações. A radiopacidade foi avaliada utilizando um sistema digital com placas de fósforo VistaScan (Dürr Dental GmbH & CO. KG, Bietigheim- Bissingen, Alemanha) sendo analisadas através do software DBSWIN 4.5, quanto a densidade radiográfica. As demais propriedades avaliadas foram: grau de conversão através de FTIR; resistência à flexão, baseada na normatização da ISO 4049/2010. Radiopacidade de resinas adesivas experimentais com ao menos 30% sulfato de bário ou óxido de bismuto ou 40% de zircônia apresentaram radiopacidade semelhante a 2mm de alumínio. Resinas adesivas com ao menos 20% de fluoreto de itérbio apresentaram radiopacidade satisfatória (2mm de Al) sem influenciar outras propriedades. / The radiopacity of restorative materials should be sufficient to allow the clinician to distinguish the material from normal and demineralized tissues. It is recognized that unfilled resin adhesives are radiolucent which could be reached with radiopaquing agents’ addition. The aim of this study is to evaluate, in an experimental adhesive resin, the influence of radiopaquing agents at polymer properties. A model adhesive resin was formulated with 50% of Bis-GMA, 25% of TEGDMA, 25% of HEMA in weight, and camphorquinone and EDAB (1%mol). The experimental groups were formed with addition of six radiopaquing agents: titanium dioxide, bismuth oxide, barium sulfate, quartz, zirconium, and ytterbium trifluoride at different concentration. The radiopacity was evaluated using an aluminum step-wedge and VistaScan (Dürr Dental GmbH & CO. KG, Bietigheim-Bissingen, Alemanha) phosphorous plates radiographs digital system and DBSWIN 4.5 software. The other properties evaluated were degree of conversion with FTIR and flexural strength, based at ISO 4049/2010. Radiopacity of model adhesive resins with at least 30% of barium sulfate or bismuth oxide or 40% of zircon showed no significant differences to 2mm of aluminum. Adhesive resin with at least 20% addition of ytterbium trifluoride presented satisfactory radiopacity (Al 2mm) without influencing other properties.
12

Síntese de blendas co-monoméricas radiopacas de aplicação odontológica

Collares, Fabrício Mezzomo January 2010 (has links)
A radiopacidade dos materiais restauradores deve permitir distinguí-los da estrutura dental. Os adesivos dentinários normalmente, não possuem radiopacidade satisfatória a qual pode ser buscada com o acréscimo de substâncias que apresentem essa característica. Entretanto, esses materiais não devem interferir negativamente nas propriedades do polímero formado. O objetivo deste estudo foi avaliar a influência da adição de substâncias radiopacificantes em uma resina adesiva experimental nas propriedades do polímero. Uma resina adesiva experimental foi formulada com 50 % de Bis- GMA, 25 % TEGDMA, e 25 % HEMA, em peso, acrescido de Canforoquinona e EDAB (1% /mol). Para formar os grupos experimentais seis substâncias foram adicionadas à resina base: dióxido de titânio, óxido de bismuto, sulfato de bário, quartzo, dióxido de zircônio e trifluoreto de itérbio, em diferentes concentrações. A radiopacidade foi avaliada utilizando um sistema digital com placas de fósforo VistaScan (Dürr Dental GmbH & CO. KG, Bietigheim- Bissingen, Alemanha) sendo analisadas através do software DBSWIN 4.5, quanto a densidade radiográfica. As demais propriedades avaliadas foram: grau de conversão através de FTIR; resistência à flexão, baseada na normatização da ISO 4049/2010. Radiopacidade de resinas adesivas experimentais com ao menos 30% sulfato de bário ou óxido de bismuto ou 40% de zircônia apresentaram radiopacidade semelhante a 2mm de alumínio. Resinas adesivas com ao menos 20% de fluoreto de itérbio apresentaram radiopacidade satisfatória (2mm de Al) sem influenciar outras propriedades. / The radiopacity of restorative materials should be sufficient to allow the clinician to distinguish the material from normal and demineralized tissues. It is recognized that unfilled resin adhesives are radiolucent which could be reached with radiopaquing agents’ addition. The aim of this study is to evaluate, in an experimental adhesive resin, the influence of radiopaquing agents at polymer properties. A model adhesive resin was formulated with 50% of Bis-GMA, 25% of TEGDMA, 25% of HEMA in weight, and camphorquinone and EDAB (1%mol). The experimental groups were formed with addition of six radiopaquing agents: titanium dioxide, bismuth oxide, barium sulfate, quartz, zirconium, and ytterbium trifluoride at different concentration. The radiopacity was evaluated using an aluminum step-wedge and VistaScan (Dürr Dental GmbH & CO. KG, Bietigheim-Bissingen, Alemanha) phosphorous plates radiographs digital system and DBSWIN 4.5 software. The other properties evaluated were degree of conversion with FTIR and flexural strength, based at ISO 4049/2010. Radiopacity of model adhesive resins with at least 30% of barium sulfate or bismuth oxide or 40% of zircon showed no significant differences to 2mm of aluminum. Adhesive resin with at least 20% addition of ytterbium trifluoride presented satisfactory radiopacity (Al 2mm) without influencing other properties.
13

"Desinfecção da Dentina Radicular pela Irradiação dos Lasers de Nd: YAG e Er: YAG: um Modelo "in vitro"" / Disinfection of intracanal dentin by ND:YAG, HO:YAG and ER:YAG laser irradiation: an in vitro model

Cecchini, Silvia Cristina Mafra 05 July 2001 (has links)
RESUMO Desinfecção da dentina radicular pela irradiação dos lasers de ND:YAG, HO:YAG e ER:YAG: um modelo in vitro A provável causa do insucesso da terapia endodôntica é a persistência de microrganismos colonizando os túbulos dentinários. Para reduzir o risco de insucesso e, se possível, o tempo despendido no tratamento endodôntico, novos equipamentos e materiais são constantemente desenvolvidos. O objetivo desta investigação foi estudar o efeito da irradiação laser intracanal na desinfecção dos túbulos dentinários de dentes bovinos recém-extraídos, utilizando-se um modelo in vitro. Os grupos irradiados pelos vários lasers foram comparados ao tratamento com hidróxido de cálcio, freqüentemente utilizado como medicação intracanal. O cemento radicular foi removido, o canal preparado e os dentes, cortados, resultando em 180 corpos de prova padronizados. Para promover a colonização bacteriana, os corpos de prova foram incubados, a 37 o C, em frascos contendo caldo de tripticase de soja e Enterococcus faecalis, o qual continha um plasmídeo que permitiu o seu crescimento em um meio seletivo com cloranfenicol. Os corpos de prova foram divididos em cinco grupos experimentais e três grupos-controle. Para irradiação foram utilizados os lasers pulsados de: Ho:YAG a 2,1 µm; Nd:YAG (1,06 µm); e Er:YAG (2,94 µm) com e sem refrigeração ar/água. Os grupos tratados receberam três parâmetros diferentes de irradiação com cada tipo de laser: energia abaixo do limiar de modificação física (physical modification threshold - ½ do PMT) por 60s; no limiar (PMT) por 60s; e, acima do limiar (120s). O Grupo 5 recebeu sete dias de tratamento com hidróxido de cálcio. Como controles, três espécimes para cada grupo receberam água estéril (controle negativo), três receberam KI3, após exposição à bactéria (controle negativo) e três não receberam tratamento após exposição à bactéria (controle positivo). A quantidade de bactérias foi estimada mediante a contagem de unidades formadoras de colônias (u.f.c.). De modo a avaliar, paralelamente, se os comprimentos de onda laser utilizados no experimento poderiam ser absorvidos pelo E. faecalis, foram obtidos espectros de absorção no UV, VIS e IR, por meio de espectroscopia. A análise estatística mostrou uma redução bacteriana como segue: Ho:YAG > hidróxido de cálcio > Nd:YAG > Er:YAG com refrigeração ar/água > Er:YAG sem refrigeração ar/água. Houve uma significativa redução bacteriana no grupo irradiado pelo Ho:YAG no limiar de modificação – PMT (50 mJ, 10 Hz, 66 J/cm 2 , por 120s), seguida pelo Ho:YAG a 50 mJ, 10 Hz, 33J/cm 2 , por 60s e pelo grupo que recebeu hidróxido de cálcio. Os dois últimos grupos não apresentaram diferenças estatísticas significativas. O espectro de absorção pelas bactérias (E. faecalis) nas faixas dos comprimentos de onda do UV e VIS apresentou picos de absorção em 361 nm e em 377 nm (UV). Já o infravermelho próximo revelou uma baixa absorção pelo microrganismo testado. / SUMMARY Disinfection of intracanal dentin by Nd:YAG, Ho:YAG and Er:YAG laser irradiation: an in vitro model A possible cause for root canal failure is the persistence of bacteria that have colonized dentinal tubules. To reduce this risk and, if possible, to also shorten the time-consuming endodontic therapy, new equipment and materials are constantly being introduced. The aim of the present investigation was to study the effect of disinfection of dentinal tubules by intracanal laser irradiation using an in vitro model. The groups irradiated by various lasers were compared with calcium hydroxide, a material frequently used as intracanal medication between appointments. Freshly extracted, intact bovine incisors were used. The root cementum was removed and the teeth cut to produce 180 standardized specimens. For bacterial colonization, specimens were incubated at 37 o C in test tubes with Tryptic Soy Broth and Enterococcus faecalis, which carried a plasmid that allowed the growth in a selective medium containing chloramphenicol. The specimens were divided in five treatment groups and three control groups. For irradiation, pulsed delivered Ho:YAG laser at 2.1 µm, Nd:YAG laser (1.06 µm), and Er:YAG and Er:YAG laser (2.94µm) with and without air/water coolant, were used. Lasers groups received three different laser settings for treatment: output energy below the physical modification threshold (½ of PMT) for 60 sec, at the PMT for 60 sec and above the PMT (120 sec). Group 5 received a seven-day treatment with calcium hydroxide. As controls, three specimens for each treatment group received sterile water instead of bacteria (negative control), three received iodine potassium-iodide after bacterial exposure (negative control), and three did not receive treatment after bacterial exposure (positive control). The number of bacteria was estimated by counting CFU. In order to evaluate whether the lasers used in the experiment could be absorbed by the bacteria E. faecalis, an UV, VIS and NIR spectra were obtained using a spectrophotometer. Statistical analysis showed the bacterial reduction as follow: Ho:YAG laser > hidróxido de cálcio> Nd:YAG laser > Er:YAG laser with air/water coolant > Er:YAG laser without air/water coolant. There was a significantly higher bacterial reduction in the group irradiated by the Ho:YAG at the PMT (50mJ, 10 Hz, 66 J/cm 2 for 120 sec), followed by Ho:YAG irradiated at 50mJ, 10 Hz, 33 J/cm 2 for 60 sec, and the group that received calcium hydroxide. The latter two groups were not significantly different. The UV and VIS absorbance spectrum presented two absorbance peaks at 361nm and 337nm (UV). The NIR spectrum revealed a very low absorbance by the E. faecalis.
14

Influência da espessura de dentina, da constrição apical e do diâmetro do forame apical na precisão de leitura com localizadores foraminais eletrônicos / Influence of dentin thickness, apical constriction and diameter of the apical foramen in the accuracy of readings with electronic apex locators.

Orosco, Fernando Accorsi 19 November 2010 (has links)
Este trabalho teve como objetivo avaliar a influência da espessura de dentina radicular apical, da constrição apical e do diâmetro do forame apical na precisão de leituras realizadas com os localizadores foraminais eletrônicos Mini Apex Locator e Root ZX II®. Foram utilizados 30 incisivos inferiores permanentes unirradiculados de humanos, extraídos, com raízes íntegras e ápices completamente formados e portadores de um único canal. Por meio de um paquímetro, as espessuras radiculares dos dentes foram medidas, no sentido mésio-distal a 1,0 e a 4,0mm aquém do forame apical. Após a abertura coronária, uma lima tipo K no 10, munida de limitador de penetração, foi introduzida no canal radicular até que sua extremidade pudesse ser visualizada na altura do forame, com o auxílio de um microscópio óptico com aumento de 7,8X. Dessa medida, subtraiu-se 1,0mm, estabelecendo-se o comprimento de trabalho. A dilatação do canal radicular foi feita, inicialmente, com brocas de Gates Glidden, em ordem numérica decrescente, da número 5 até a número1, até 4,0mm aquém do forame apical. Os dentes foram fixados em um modelo experimental especialmente desenvolvido para permitir a medição com os localizadores foraminais eletrônicos. Tal modelo era constituído por dois segmentos de PVC: um de menor calibre, com diâmetro correspondente a meia polegada por 2,0cm de comprimento, com as duas extremidades abertas e outro, de maior calibre, com uma das extremidades fechada e com diâmetro interno equivalente ao diâmetro externo do primeiro segmento (3/4 de polegada). No segmento de maior diâmetro, foi feito um orifício lateral que permitiu o posicionamento do eletrodo labial do localizador foraminal eletrônico e, para a medição, no seu interior, foi colocado alginato e, então, encaixado o componente de menor diâmetro, fazendo com que o ápice radicular ficasse imerso no alginato. Foram realizadas as leituras com os localizadores, iniciando-se com a lima tipo K no 10 e seguindo-se a seqüência de instrumentação e medida até a lima tipo K no 130; a lima tipo K no 10 foi utilizada em todos os diâmetros. Terminada essa fase, os dentes tiveram os canais sobreinstrumentados, isto é, a ponta da lima ultrapassou o forame apical em 1,0mm, a partir da lima tipo K no 25 e seguindo até a lima tipo K no 130; novas medidas foram obtidas com cada lima que sobreinstrumentou o forame e a lima no 10 foi utilizada em todos os diâmetros. Em todos os casos o canal radicular estava preenchido com hipoclorito de sódio a 1%. Para a análise estatística foram empregados os testes de Análise de Variância a dois critérios e de Tukey. Os resultados indicaram que as variáveis capazes de influenciar a recisão das leituras com os localizadores foraminais eletrônicos foram a eliminação da constrição apical com o consequente aumento do diâmetro do forame apical, ao contrário da espessura da parede dentinária do canal radicular, que não interferiu significativamente na precisão das leituras. / This study evaluated the influence of the apical root dentin thickness, apical constriction and diameter of the apical foramen in the accuracy of readings obtained using the electronic apex locators Mini Apex Locator and Root ZX II ®. The study was conducted on 30 extracted human single-rooted permanent mandibular incisors, with intact and completely formed roots and presenting a single canal. The root thickness of the teeth was measured with a pachymeter in mesiodistal direction, at 1.0 and 4.0mm from the apical foramen. After coronal opening, a 10 K file with a stop was introduced in the root canal until its end could be observed at the level of the apical foramen, with aid of a light microscope with 7.8X magnification. One millimeter was subtracted from this measurement for establishment of the working length. Enlargement of the root canal was initially performed using Gates Glidden burs, in decreasing order, from number 5 to number 1, up to 4.0mm beyond the apical foramen. The teeth were fixated in an experimental model especially designed to allow the measurement with the electronic apex locators. This model was composed of two PVC segments: one smaller, with diameter corresponding to half inch with 2.0cm length, with both ends open; and the other, with larger diameter, with one end closed and internal diameter similar to the external diameter of the first segment (3/4 inch). In the segment with greater diameter, a lateral orifice was made to allow positioning of the lip electrode of the electronic apex locator. For the measurement, alginate was poured and the component with smaller diameter was fitted, so as the root apex was immersed in alginate. Readings were performed using the electronic apex locators, initiating with a 10 K file and following the sequence of instrumentation and measurement up to 130 K file. The 10 K file was used in all diameters. After this stage, the root canals were overinstrumented, i.e. the file tip was introduced until 1.0mm beyond the apical foramen, beginning with 25 K file up to 130 K file; new measurements were obtained with each file overinstrumenting the apical foramen, and the 10 K file was used in all diameters. In all cases, the root canal was irrigated with 1% sodium hypochlorite. Statistical analysis was performed by two-way analysis of variance and the Tukey test. The results indicated that the variables that may influence the accuracy of readings with the electronic apex locators were the elimination of apical constriction with consequent increase in the diameter of the apical foramen, different from the thickness of the root canal dentinal wall, which did not significantly influence the accuracy of readings.
15

"Desinfecção da Dentina Radicular pela Irradiação dos Lasers de Nd: YAG e Er: YAG: um Modelo "in vitro"" / Disinfection of intracanal dentin by ND:YAG, HO:YAG and ER:YAG laser irradiation: an in vitro model

Silvia Cristina Mafra Cecchini 05 July 2001 (has links)
RESUMO Desinfecção da dentina radicular pela irradiação dos lasers de ND:YAG, HO:YAG e ER:YAG: um modelo in vitro A provável causa do insucesso da terapia endodôntica é a persistência de microrganismos colonizando os túbulos dentinários. Para reduzir o risco de insucesso e, se possível, o tempo despendido no tratamento endodôntico, novos equipamentos e materiais são constantemente desenvolvidos. O objetivo desta investigação foi estudar o efeito da irradiação laser intracanal na desinfecção dos túbulos dentinários de dentes bovinos recém-extraídos, utilizando-se um modelo in vitro. Os grupos irradiados pelos vários lasers foram comparados ao tratamento com hidróxido de cálcio, freqüentemente utilizado como medicação intracanal. O cemento radicular foi removido, o canal preparado e os dentes, cortados, resultando em 180 corpos de prova padronizados. Para promover a colonização bacteriana, os corpos de prova foram incubados, a 37 o C, em frascos contendo caldo de tripticase de soja e Enterococcus faecalis, o qual continha um plasmídeo que permitiu o seu crescimento em um meio seletivo com cloranfenicol. Os corpos de prova foram divididos em cinco grupos experimentais e três grupos-controle. Para irradiação foram utilizados os lasers pulsados de: Ho:YAG a 2,1 µm; Nd:YAG (1,06 µm); e Er:YAG (2,94 µm) com e sem refrigeração ar/água. Os grupos tratados receberam três parâmetros diferentes de irradiação com cada tipo de laser: energia abaixo do limiar de modificação física (physical modification threshold - ½ do PMT) por 60s; no limiar (PMT) por 60s; e, acima do limiar (120s). O Grupo 5 recebeu sete dias de tratamento com hidróxido de cálcio. Como controles, três espécimes para cada grupo receberam água estéril (controle negativo), três receberam KI3, após exposição à bactéria (controle negativo) e três não receberam tratamento após exposição à bactéria (controle positivo). A quantidade de bactérias foi estimada mediante a contagem de unidades formadoras de colônias (u.f.c.). De modo a avaliar, paralelamente, se os comprimentos de onda laser utilizados no experimento poderiam ser absorvidos pelo E. faecalis, foram obtidos espectros de absorção no UV, VIS e IR, por meio de espectroscopia. A análise estatística mostrou uma redução bacteriana como segue: Ho:YAG > hidróxido de cálcio > Nd:YAG > Er:YAG com refrigeração ar/água > Er:YAG sem refrigeração ar/água. Houve uma significativa redução bacteriana no grupo irradiado pelo Ho:YAG no limiar de modificação – PMT (50 mJ, 10 Hz, 66 J/cm 2 , por 120s), seguida pelo Ho:YAG a 50 mJ, 10 Hz, 33J/cm 2 , por 60s e pelo grupo que recebeu hidróxido de cálcio. Os dois últimos grupos não apresentaram diferenças estatísticas significativas. O espectro de absorção pelas bactérias (E. faecalis) nas faixas dos comprimentos de onda do UV e VIS apresentou picos de absorção em 361 nm e em 377 nm (UV). Já o infravermelho próximo revelou uma baixa absorção pelo microrganismo testado. / SUMMARY Disinfection of intracanal dentin by Nd:YAG, Ho:YAG and Er:YAG laser irradiation: an in vitro model A possible cause for root canal failure is the persistence of bacteria that have colonized dentinal tubules. To reduce this risk and, if possible, to also shorten the time-consuming endodontic therapy, new equipment and materials are constantly being introduced. The aim of the present investigation was to study the effect of disinfection of dentinal tubules by intracanal laser irradiation using an in vitro model. The groups irradiated by various lasers were compared with calcium hydroxide, a material frequently used as intracanal medication between appointments. Freshly extracted, intact bovine incisors were used. The root cementum was removed and the teeth cut to produce 180 standardized specimens. For bacterial colonization, specimens were incubated at 37 o C in test tubes with Tryptic Soy Broth and Enterococcus faecalis, which carried a plasmid that allowed the growth in a selective medium containing chloramphenicol. The specimens were divided in five treatment groups and three control groups. For irradiation, pulsed delivered Ho:YAG laser at 2.1 µm, Nd:YAG laser (1.06 µm), and Er:YAG and Er:YAG laser (2.94µm) with and without air/water coolant, were used. Lasers groups received three different laser settings for treatment: output energy below the physical modification threshold (½ of PMT) for 60 sec, at the PMT for 60 sec and above the PMT (120 sec). Group 5 received a seven-day treatment with calcium hydroxide. As controls, three specimens for each treatment group received sterile water instead of bacteria (negative control), three received iodine potassium-iodide after bacterial exposure (negative control), and three did not receive treatment after bacterial exposure (positive control). The number of bacteria was estimated by counting CFU. In order to evaluate whether the lasers used in the experiment could be absorbed by the bacteria E. faecalis, an UV, VIS and NIR spectra were obtained using a spectrophotometer. Statistical analysis showed the bacterial reduction as follow: Ho:YAG laser > hidróxido de cálcio> Nd:YAG laser > Er:YAG laser with air/water coolant > Er:YAG laser without air/water coolant. There was a significantly higher bacterial reduction in the group irradiated by the Ho:YAG at the PMT (50mJ, 10 Hz, 66 J/cm 2 for 120 sec), followed by Ho:YAG irradiated at 50mJ, 10 Hz, 33 J/cm 2 for 60 sec, and the group that received calcium hydroxide. The latter two groups were not significantly different. The UV and VIS absorbance spectrum presented two absorbance peaks at 361nm and 337nm (UV). The NIR spectrum revealed a very low absorbance by the E. faecalis.
16

Influência da espessura de dentina, da constrição apical e do diâmetro do forame apical na precisão de leitura com localizadores foraminais eletrônicos / Influence of dentin thickness, apical constriction and diameter of the apical foramen in the accuracy of readings with electronic apex locators.

Fernando Accorsi Orosco 19 November 2010 (has links)
Este trabalho teve como objetivo avaliar a influência da espessura de dentina radicular apical, da constrição apical e do diâmetro do forame apical na precisão de leituras realizadas com os localizadores foraminais eletrônicos Mini Apex Locator e Root ZX II®. Foram utilizados 30 incisivos inferiores permanentes unirradiculados de humanos, extraídos, com raízes íntegras e ápices completamente formados e portadores de um único canal. Por meio de um paquímetro, as espessuras radiculares dos dentes foram medidas, no sentido mésio-distal a 1,0 e a 4,0mm aquém do forame apical. Após a abertura coronária, uma lima tipo K no 10, munida de limitador de penetração, foi introduzida no canal radicular até que sua extremidade pudesse ser visualizada na altura do forame, com o auxílio de um microscópio óptico com aumento de 7,8X. Dessa medida, subtraiu-se 1,0mm, estabelecendo-se o comprimento de trabalho. A dilatação do canal radicular foi feita, inicialmente, com brocas de Gates Glidden, em ordem numérica decrescente, da número 5 até a número1, até 4,0mm aquém do forame apical. Os dentes foram fixados em um modelo experimental especialmente desenvolvido para permitir a medição com os localizadores foraminais eletrônicos. Tal modelo era constituído por dois segmentos de PVC: um de menor calibre, com diâmetro correspondente a meia polegada por 2,0cm de comprimento, com as duas extremidades abertas e outro, de maior calibre, com uma das extremidades fechada e com diâmetro interno equivalente ao diâmetro externo do primeiro segmento (3/4 de polegada). No segmento de maior diâmetro, foi feito um orifício lateral que permitiu o posicionamento do eletrodo labial do localizador foraminal eletrônico e, para a medição, no seu interior, foi colocado alginato e, então, encaixado o componente de menor diâmetro, fazendo com que o ápice radicular ficasse imerso no alginato. Foram realizadas as leituras com os localizadores, iniciando-se com a lima tipo K no 10 e seguindo-se a seqüência de instrumentação e medida até a lima tipo K no 130; a lima tipo K no 10 foi utilizada em todos os diâmetros. Terminada essa fase, os dentes tiveram os canais sobreinstrumentados, isto é, a ponta da lima ultrapassou o forame apical em 1,0mm, a partir da lima tipo K no 25 e seguindo até a lima tipo K no 130; novas medidas foram obtidas com cada lima que sobreinstrumentou o forame e a lima no 10 foi utilizada em todos os diâmetros. Em todos os casos o canal radicular estava preenchido com hipoclorito de sódio a 1%. Para a análise estatística foram empregados os testes de Análise de Variância a dois critérios e de Tukey. Os resultados indicaram que as variáveis capazes de influenciar a recisão das leituras com os localizadores foraminais eletrônicos foram a eliminação da constrição apical com o consequente aumento do diâmetro do forame apical, ao contrário da espessura da parede dentinária do canal radicular, que não interferiu significativamente na precisão das leituras. / This study evaluated the influence of the apical root dentin thickness, apical constriction and diameter of the apical foramen in the accuracy of readings obtained using the electronic apex locators Mini Apex Locator and Root ZX II ®. The study was conducted on 30 extracted human single-rooted permanent mandibular incisors, with intact and completely formed roots and presenting a single canal. The root thickness of the teeth was measured with a pachymeter in mesiodistal direction, at 1.0 and 4.0mm from the apical foramen. After coronal opening, a 10 K file with a stop was introduced in the root canal until its end could be observed at the level of the apical foramen, with aid of a light microscope with 7.8X magnification. One millimeter was subtracted from this measurement for establishment of the working length. Enlargement of the root canal was initially performed using Gates Glidden burs, in decreasing order, from number 5 to number 1, up to 4.0mm beyond the apical foramen. The teeth were fixated in an experimental model especially designed to allow the measurement with the electronic apex locators. This model was composed of two PVC segments: one smaller, with diameter corresponding to half inch with 2.0cm length, with both ends open; and the other, with larger diameter, with one end closed and internal diameter similar to the external diameter of the first segment (3/4 inch). In the segment with greater diameter, a lateral orifice was made to allow positioning of the lip electrode of the electronic apex locator. For the measurement, alginate was poured and the component with smaller diameter was fitted, so as the root apex was immersed in alginate. Readings were performed using the electronic apex locators, initiating with a 10 K file and following the sequence of instrumentation and measurement up to 130 K file. The 10 K file was used in all diameters. After this stage, the root canals were overinstrumented, i.e. the file tip was introduced until 1.0mm beyond the apical foramen, beginning with 25 K file up to 130 K file; new measurements were obtained with each file overinstrumenting the apical foramen, and the 10 K file was used in all diameters. In all cases, the root canal was irrigated with 1% sodium hypochlorite. Statistical analysis was performed by two-way analysis of variance and the Tukey test. The results indicated that the variables that may influence the accuracy of readings with the electronic apex locators were the elimination of apical constriction with consequent increase in the diameter of the apical foramen, different from the thickness of the root canal dentinal wall, which did not significantly influence the accuracy of readings.
17

Einfluss des Feuchtigkeitsgehalts des Wurzelkanaldentins auf die Entstehung und den Nachweis von Mikrorissen - Eine Mikro-Computertomografie-Studie / Moisture content of root canal dentin affects detection of microcracks using micro-computed tomography

Müller, Christine 22 June 2020 (has links)
No description available.
18

Avaliação dos efeitos do laser de Er,Cr:YSGG sobre superfícies radiculares expostas no tratamento da hipersensibilidade dentinária cervical. Estudo in vitro e in vivo / Desensitizing effects of Er:YAG and Er,Cr:YSGG lasers on dentin hypersensitivity. An in vitro and in vivo study

Aranha, Ana Cecilia Corrêa 03 August 2005 (has links)
O objetivo deste estudo foi o de avaliar os efeitos da irradiação laser de Er,Cr:YSGG em superfícies dentinárias no tratamento da hipersensibilidade dentinária cervical, em busca de um protocolo para ser aplicado clinicamente. Para o teste de permeabilidade, foram preparados 144 pré-molares, as coroas seccionadas e as raízes impermeabilizadas. Duas áreas de irradiação antagônicas foram delimitadas e livres da impermeabilização (controle e experimental). A seguir, os dentes foram subdivididos em dois sub-grupos, diferindo o condicionamento da superfície irradiada (EDTA 24% e ácido fosfórico 35%) e em grupos diferindo o protocolo:G1)Er:YAG, 60mJ/2Hz; G2)0,25W; G3)0,5W; G4)0,75W; G5)1W, G6)1,25W; G7)1,50W; G8)1,75W G9)2W. Após as irradiações, os espécimes foram imersos em azul de metileno 2% por 4 horas, e incluídos em resina epóxica para a realização dos cortes longitudinais. Estes tiveram suas imagens trabalhadas em computador para mensuração do nível de infiltração. Os dados foram submetidos à análise estatística. O Sub-grupo 1, condicionado com EDTA, apresentou diferenças entre os grupos sendo que as amostras irradiadas com Er:YAG demonstraram menor infiltração, diferindo estatisticamente dos grupos 3, 6 e 9. Os resultados do sub-grupo 2 mostraram que as médias das amostras irradiadas com Er:YAG tenderam a zero entretanto, não houve diferença entre os grupos. Na Fase B, fragmentos de dentina foram obtidos da região cervical de dentes humanos, preparados para análise em microscopia eletrônica de varredura. Morfologicamente, observou-se oclusão parcial dos túbulos dentinários após irradiação com Er:YAG e Er,Cr:YSGG nas condições de 0,25W e 0,50W. A partir de 0.75W, foi observado abertura dos túbulos e à medida que as energias aumentaram, foram observadas carbonização e fendas. De posse dos resultados dos trabalhos in vitro, foram selecionados os parâmetros para a aplicação e o acompanhamento clínico de 1 mês: G1)controle (placebo); G2)Er:YAG; G3)Er,Cr:YSGG 0,25W e G4)Er,Cr:YSGG 0,75W. Após a triagem, foram selecionados voluntários de acordo com critérios de exclusão e inclusão. O nível de sensibilidade de cada voluntário foi avaliado através da escala visual analógica de dor (VAS) com auxílio do ar da seringa tríplice 1 semana antes (Pré-1), 5 minutos anterior ao tratamento (Pré-2), após 5 minutos (Pós-1), 1 semana (Pós-2) e 1 mês após o tratamento (Pós-3). Os dados foram coletados e submetidos à análise estatística separadamente para os dois estímulos realizados: spray de ar e sonda exploradora. Tanto para o estímulo ar quanto para o estímulo sonda, não foram observadas diferenças estatisticamente significantes nas escalas Pré-1 e Pré-2, concluindo que os pacientes estavam padronizados e não houve efeito da profilaxia nos níveis de dor. Ao estímulo do spray de ar, nota-se uma redução nos níveis de dor na escala Pós-1, porém há uma estabilidade dos valores das escalas seguintes. O grupo 2 (Er:YAG) apresentou o menor nível de dor quando comparado aos outros grupos. Ao estímulo mecânico foi observado que o grupo 4 (Er,Cr:YSGG 0,50W) demonstrou o decréscimo de dor mais acentuado imediatamente após o tratamento, porém ao final do estudo, apresentou os maiores níveis de dor. Os grupos 1, 2 e 3 apresentam redução de dor, porém estatisticamente diferentes do grupo 4. Com base nos resultados apresentados e dentro dos limites e parâmetros estudados, pode-se concluir que nenhuma condição foi capaz de eliminar completamente a microinfiltração e diminuir a permeabilidade dentinária; porém o laser de Er:YAG e o laser de Er,Cr:YSGG 0,25W apresentaram resultados satisfatórios nos três estudos realizados. / The aim of the present study was to determine the correct parameters of the Er,Cr:YSGG laser in the treatment of cervical dentin hypersensitivity. This work was presented in 3 different stages. In the first one, it was evaluated the decrease in dentin permeability of dentinal tubules after Er,Cr:YSGG laser irradiation in radicular surfaces. Ninety premolars were prepared with its crows sectioned, and the roots completely impermeabilized. Two antagonist areas of irradiation were determined as control and experimental. Each surface was conditioned with EDTA 24% (sub-group1) and phosphoric acid 35% (sub-group2) and the selected parameters were: 1)Er:YAG, 60mJ, 2Hz, 4 irradiations of 20sec each, defocused mode; and groups 2 to 9 received irradiation with Er,Cr:YSGG laser, 20Hz, Z6 tip, 600µm diameter, defocus mode, 0% of air and water: 2)Er,Cr:YSGG 0,25W; 3) 0,5W; 4) 0,75W; 5) 1,0W; 6) 1,25W, 7) 1,50W, 8) 2W; 9) 2 W. After irradiation, samples were immersed in a solution of methylene blue for 4 hours, washed for 5 min and included in epoxy resin to allow longitudinal cuts. The images were digitalized and computed worked. Data was statistically analyzed. Although the samples irradiated with Er:YAG showed less microleakage, the sub-group 1 showed differences between the groups, statistically different from groups 3, 6 e 9. The results of the sub-group 2 showed that the mean values of the Er:YAG samples had a tendency to be negative, however, no differences were detected between the groups. In the second stage, cuts from the cervical area were obtained and prepared for scanning electron microscopy to evaluate the superficial morphology. It was observed the partial closure of dentinal tubules after the irradiation with Er:YAG and Er,Cr:YSGG laser in the 0.25 and 0.50W protocols. From the 0.75W until 2W, it was observed the dentinal tubules opened as the energy densities raised. With the results of the in vitro studies, the parameters were selected: G1)control; G2)Er:YAG; G3)Er,Cr:YSGG 0,25W e G4)Er,Cr:YSGG 0,75W. Thirty subjects, who met the entry criteria, were admitted into the study. The assessment method used to quantify sensitivity was the cold air syringe, recorded by the visual analogue scale (VAS), prior to treatment as baseline (Pre-1), immediately before (Pre-2) and immediately after (Post-1) the topical treatment, after 1 week (Post-2) and after 1 month (Post-3). Teeth were assigned to the 4 groups. After the follow-up, data was collected and submitted to statistical analysis for both kinds of stimulus: evaporative (air) and mechanical (probe). For both air and probe it was not observed differences among the Pre-1 and Pre-2 moments, for what it can be concluded that patients were standardized. Analyzing the evaporative stimulus, it can be observed the reduction in the pain level immediately after the treatment; however there was stability in the next values. Group 2 (Er:YAG) showed the least level of pain. Throughout the mechanical stimulus, it was observed that group 4 (Er,Cr:YSGG 0,50W) showed the most pronounced decrease of pain immediately after treatment, however, at the end of the study, the levels of pain increased. Groups 1, 2 e 3 showed reduction of pain, statistically different from the group 4. Based on the results and within the limits of this study, it can be concluded that none of the parameters and lasers studied were capable of eliminate the microleakage and decrease the dentin permeability, however, the Er:YAG and Er,Cr:YSGG 0,25W lasers showed satisfactory results in the three studies performed.
19

Ausência de correlação entre a penetração do cimento AH Plus nos túbulos dentinários e a qualidade do selamento / Lack of correlation between AH Plus sealer penetration into dentinal tubules and sealability

Maria Cláudia Brandão de Souza 30 March 2010 (has links)
O presente estudo objetivou testar experimentalmente a existência da possível correlação entre a penetração de cimento nos túbulos dentinários e a qualidade do selamento. Foram utilizados 60 incisivos centrais superiores humanos que formaram um único grupo experimental. Após a eliminação das porções coronárias, as raízes foram padronizadas em 13 mm de comprimento. A instrumentação dos canais foi realizada no sentido coroa-ápice, e o comprimento de trabalho estabelecido a 1 mm aquém do forame apical. Como solução irrigadora foi empregado o NaOCl a 5,25% e ao final, EDTA a 17%. Em seguida, todos os canais foram obturados com guta-percha e cimento AH Plus marcado com um corante fluorescente. Para determinar a qualidade do selamento das obturações endodônticas, as amostras foram submetidas ao modelo de infiltração de glicose sob pressão. As raízes foram montadas em um dispositivo de dupla-câmara selada para permitir a infiltração da glicose. Como controle negativo foram utilizados 4 dentes hígidos, e como controle positivo, 2 dentes instrumentados porém, não obturados. Foram utilizados 0,75 mL de solução de glicose a 1 mol/L na câmara superior e 0,75 mL de água deionizada na câmara inferior. Os dispositivos foram conectados a um sistema de distribuição de pressão desenvolvido com o objetivo de permitir a infiltração de 32 amostras em uma mesma etapa. A solução de glicose foi forçada apicalmente sob uma pressão de 15 psi durante 1 hora. Uma alíquota de 50 L foi coletada da câmara inferior para quantificar a glicose infiltrada. A concentração de glicose foi determinada através de um método enzimático com o auxílio do Kit Glucose HK e de um espectrofotômetro em um comprimento de onda de 340 nm. Na sequência, as amostras foram desacopladas dos corpos de prova, embutidas em resina epóxi e cortadas em 3 secções transversais. Uma sequência de preparação metalográfica padrão foi realizada para permitir a observação da penetração de cimento nos túbulos dentinários por meio de microscopia confocal e óptica. Os dados obtidos nos 2 experimentos foram cruzados pelo teste de correlação de Spearman, o qual revelou a inexistência de qualquer possibilidade de correlação (r = 0,12). Com base nesses resultados, o presente trabalho concluiu que, dentro das condições experimentais usadas, a quantidade de cimento presente dentro dos túbulos dentinários não teve relação com a qualidade do selamento produzido. / The purpose of the present study was to experimentally test the potential correlation between tubular dentin sealer penetration and sealability. Sixty human maxillary central incisors were selected in order to compose a single experimental group. After removing of crowns, the roots were standardized at 13 mm in length. A crown-down root canal instrumentation was performed 1mm short of the apical foramen (working length). How irrigating solution was used 5.25% NaOCl and final, 17% EDTA. Then, all root canals were filled with gutta percha and AH Plus sealer labeled with a fluorescent dye. To determine the sealability pattern, samples were submitted to glucose leakage model under pressure. Four intact teeth were used as negative control while further 2 instrumented but nonfilled teeth was used as positive control. The roots were mounted in a double-chamber apparatus where 0,75 mL of 1 mol/L glucose solution was placed into the superior chamber and 0,75 mL of deionized water was placed into the inferior chamber. The devices were connected to a pressure distribution system that was developed in order to allow testing 32 specimens at the same experimental stage. The glucose solution was forced apically under a pressure of 15 psi during 1 hour. A sample of 50 L was taken from the inferior chamber and the glucose concentration was measured following an enzymatic reaction using a Glucose HK Kit readed under spectrophotometry (wave-length of 340 nm). After that, the samples were removed from the apparatus, embedded in epoxy resin and cut into 3 sections. Standard metallographic preparation was performed prior the observation of the sealer penetration into dentinal tubules by confocal and optical microscopy. Data provided by the evaluations were submitted to Spearman correlation test which revealed a lack of correlation between the two variables (r = 0.12). Therefore, the present study concluded that there was no correlation between tubular sealer penetration and sealability in non-bonding conventional root-fillings.
20

Ausência de correlação entre a penetração do cimento AH Plus nos túbulos dentinários e a qualidade do selamento / Lack of correlation between AH Plus sealer penetration into dentinal tubules and sealability

Maria Cláudia Brandão de Souza 30 March 2010 (has links)
O presente estudo objetivou testar experimentalmente a existência da possível correlação entre a penetração de cimento nos túbulos dentinários e a qualidade do selamento. Foram utilizados 60 incisivos centrais superiores humanos que formaram um único grupo experimental. Após a eliminação das porções coronárias, as raízes foram padronizadas em 13 mm de comprimento. A instrumentação dos canais foi realizada no sentido coroa-ápice, e o comprimento de trabalho estabelecido a 1 mm aquém do forame apical. Como solução irrigadora foi empregado o NaOCl a 5,25% e ao final, EDTA a 17%. Em seguida, todos os canais foram obturados com guta-percha e cimento AH Plus marcado com um corante fluorescente. Para determinar a qualidade do selamento das obturações endodônticas, as amostras foram submetidas ao modelo de infiltração de glicose sob pressão. As raízes foram montadas em um dispositivo de dupla-câmara selada para permitir a infiltração da glicose. Como controle negativo foram utilizados 4 dentes hígidos, e como controle positivo, 2 dentes instrumentados porém, não obturados. Foram utilizados 0,75 mL de solução de glicose a 1 mol/L na câmara superior e 0,75 mL de água deionizada na câmara inferior. Os dispositivos foram conectados a um sistema de distribuição de pressão desenvolvido com o objetivo de permitir a infiltração de 32 amostras em uma mesma etapa. A solução de glicose foi forçada apicalmente sob uma pressão de 15 psi durante 1 hora. Uma alíquota de 50 L foi coletada da câmara inferior para quantificar a glicose infiltrada. A concentração de glicose foi determinada através de um método enzimático com o auxílio do Kit Glucose HK e de um espectrofotômetro em um comprimento de onda de 340 nm. Na sequência, as amostras foram desacopladas dos corpos de prova, embutidas em resina epóxi e cortadas em 3 secções transversais. Uma sequência de preparação metalográfica padrão foi realizada para permitir a observação da penetração de cimento nos túbulos dentinários por meio de microscopia confocal e óptica. Os dados obtidos nos 2 experimentos foram cruzados pelo teste de correlação de Spearman, o qual revelou a inexistência de qualquer possibilidade de correlação (r = 0,12). Com base nesses resultados, o presente trabalho concluiu que, dentro das condições experimentais usadas, a quantidade de cimento presente dentro dos túbulos dentinários não teve relação com a qualidade do selamento produzido. / The purpose of the present study was to experimentally test the potential correlation between tubular dentin sealer penetration and sealability. Sixty human maxillary central incisors were selected in order to compose a single experimental group. After removing of crowns, the roots were standardized at 13 mm in length. A crown-down root canal instrumentation was performed 1mm short of the apical foramen (working length). How irrigating solution was used 5.25% NaOCl and final, 17% EDTA. Then, all root canals were filled with gutta percha and AH Plus sealer labeled with a fluorescent dye. To determine the sealability pattern, samples were submitted to glucose leakage model under pressure. Four intact teeth were used as negative control while further 2 instrumented but nonfilled teeth was used as positive control. The roots were mounted in a double-chamber apparatus where 0,75 mL of 1 mol/L glucose solution was placed into the superior chamber and 0,75 mL of deionized water was placed into the inferior chamber. The devices were connected to a pressure distribution system that was developed in order to allow testing 32 specimens at the same experimental stage. The glucose solution was forced apically under a pressure of 15 psi during 1 hour. A sample of 50 L was taken from the inferior chamber and the glucose concentration was measured following an enzymatic reaction using a Glucose HK Kit readed under spectrophotometry (wave-length of 340 nm). After that, the samples were removed from the apparatus, embedded in epoxy resin and cut into 3 sections. Standard metallographic preparation was performed prior the observation of the sealer penetration into dentinal tubules by confocal and optical microscopy. Data provided by the evaluations were submitted to Spearman correlation test which revealed a lack of correlation between the two variables (r = 0.12). Therefore, the present study concluded that there was no correlation between tubular sealer penetration and sealability in non-bonding conventional root-fillings.

Page generated in 0.0901 seconds