• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • 10
  • Tagged with
  • 20
  • 20
  • 10
  • 10
  • 8
  • 8
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Comportamento mecânico e características de desgaste de diferentes sistemas de encaixe utilizados em sobredentaduras mandibulares /

Mendoza Marin, Danny Omar. January 2017 (has links)
Orientador: Marco Antonio [UNESP] Compagnoni / Resumo: Uma ampla variedade de sistemas de encaixe para sobredentaduras retidas por implantes estão atualmente disponíveis no mercado. Estudos para avaliar o comportamento mecânico desses sistemas de encaixe tornam-se ainda necessários para uma maior compreensão das suas propriedades biomecânicas quando da sua indicação e seleção durante a confecção de sobredentaduras mandibulares. Objetivos: Avaliar a força de retenção inicial, resistência à fadiga, característica de desgaste e a influência da distância entre os implantes (16 mm, 22 mm e 29 mm) de diferentes sistemas de encaixe (O'ring, Bola Mini, Equator) utilizados em sobredentaduras mandibulares retidas por dois implantes. Metodologia: 90 corpos de prova foram confeccionados, os quais foram divididos em 09 grupos experimentais (n=10) de acordo com as distâncias estabelecidas e o sistema de encaixe. Os corpos de prova foram submetidos ao teste de fadiga mecânica utilizando a máquina de ensaios MTS 810 - Material Test System, durante 5500 ciclos de inserção/remoção (f = o,8 Hz), imersas em saliva artificial. Valores de retenção foram obtidos durante 4 períodos (0, 1500, 3000, 5500 ciclos) utilizando uma célula de carga de 1 kN e velocidade constante de 1mm/min. Um espécime de cada sistema de encaixe, utilizando a distância entre os implantes de 22 mm, foi selecionado de maneira aleatória e analisado por meio de um microscópio eletrônico de varredura para avaliação qualitativa da superfície. O teste de ANOVA dois e três fatores e o ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract:Several attachment systems for mandibular overdentures retained by implants are currently available in the market. Studies to evaluate the mechanical behavior become necessary for a better understanding of the mechanical properties of these components, helping the surgeon dentist in the correct selection during the fabrication of mandibular overdentures. Objectives: To evaluate the initial retention force, fatigue strength, wear characteristic and the influence of the distance between the implants (16 mm, 22 mm and 29 mm) of different attachment systems (O'ring, Mini Ball, Equator) used in mandibular overdentures retained by two implants. Methodology: 90 specimens were fabricated and divided into 9 groups (n = 10) according to the established distances and the attachment system. A mechanical fatigue test was applied to the specimens using a universal testing machine MTS 810 - Material Test System performing 5500 insertion/removal cycles (f=0.8 Hz), immersed in artificial saliva. Retention force values were obtained before and after 1500, 3000, and 5500 cycles using a speed of 1 mm/min and a load cell of 1 kN. One specimen from each group, using the distance between the implants of 22 mm, was randomly selected and analyzed by scanning electron microscopy for qualitative evaluation of surface. Twoway and Three-way repeated measures ANOVA and the Bonferroni post hoc test were used for statistical analyses (α=0.05). Results: For the distance of 22 mm, the O'ring system remained stable during all the periods tested and had the lowest retention values than Mini Ball and Equator systems (p<0.05). The Mini Ball system showed a significant increase in the retention force after the fatigue test (0 cycles = 21.04 ± 3.29; 5500 cycles = 24.01 ± 3.30). However, the Equator system showed a significant decrease in the retention...(Complete abstract electronic access below) / Doutor
12

Flexural strength, fracture toughness, and denture tooth adhesion of computer aided milled andprinted denture bases

Malik, Aneeqa 23 October 2019 (has links)
No description available.
13

Avaliação clínica da estabilidade dimensional de próteses totais submetidas à desinfecção por microondas

Basso, Michael Frederico Manzolli [UNESP] 27 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-27Bitstream added on 2014-06-13T21:07:01Z : No. of bitstreams: 1 basso_mfm_dr_arafo.pdf: 618642 bytes, checksum: a30b4dfd3eaaae29f0c670dfb57dbd55 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A energia por microondas tem sido recomendada para desinfetar próteses totais. Entretanto, os ciclos de desinfecção podem afetar a estabilidade dimensional das bases de próteses. Assim, o objetivo deste estudo clínico foi avaliar o efeito de dois protocolos de desinfecção por microondas na estabilidade dimensional de próteses totais, analisando a estabilidade dimensional linear, o percentual de força oclusal obtido a partir dos contatos oclusais cêntricos e as ocorrências clínicas. Foram confeccionadas próteses totais para quarenta pacientes totalmente edêntulos. Todas as próteses foram prensadas com a resina Lucitone 550. Após a colocação, aguardou-se 30 dias para submeter as próteses às condições experimentais como a seguir: Grupo 1 (G1)- 20 pacientes tiveram as próteses maxilares submetidas a desinfecção por microondas (650 W / 3 minutos), uma vez por semana, durante 4 semanas. Grupo 2 (G2)- 20 pacientes tiveram as próteses maxilares submetidas a desinfecção por microondas (650 W / 3 minutos), três vezes por semana, durante 4 semanas. Para avaliar a estabilidade dimensional linear, mensurações foram realizadas entre quatro pontos de referência (primeiros pré-molares e segundos molares bilateralmente) antes da primeira desinfecção por microondas (baseline) e após cada semana de desinfecção. Um software foi utilizado para mensurar as distâncias entre os pontos de referência a partir de fotografias padronizadas. As dimensões médiolateral e anteroposterior e a área foram calculadas. Os dados foram analisados pelos testes ANOVA two-way, Tukey e t-Student (_=0,05). O sistema T-Scan III foi utilizado para avaliar o percentual de força oclusal obtido a partir dos contatos oclusais cêntricos. Os contatos oclusais cêntricos foram capturados, antes da primeira desinfecção por microondas (baseline) e após cada semana de desinfecção, por meio... / Microwave energy has been recommended for disinfecting complete dentures. However, the microwave disinfection cycles may affect the dimensional stability of denture bases. Therefore, the purpose of this clinical study was to evaluate the effect of two microwave disinfection protocols on the dimensional stability of complete dentures, analyzing the linear dimensional stability, the percent occlusal force obtained from centric occlusal contacts and the clinical events. Complete dentures were constructed for forty totally edentulous patients. All dentures were conventionally processed with heat-polymerized acrylic resin (Lucitone 550). After insertion of complete dentures, it was expected 30 days to submit the dentures to the experimental conditions as follows: Group 1 (G1)- 20 patients had the maxillary complete dentures submitted to microwave disinfection (650 W/ 3 minutes), once a week, for four weeks. Group 2 (G2)- 20 patients had the maxillary complete dentures submitted to microwave disinfection (650 W/ 3 minutes), three times a week, for four weeks. To evaluate the linear dimensional stability, measurements were taken across four reference points (first premolars and second molars bilaterally) before of first microwave disinfection (baseline) and after each week of disinfection. Software was used to measure distances between reference points from standardized photographs. Mediolateral and anteroposterior dimensions and area between reference points were calculated. The dimensional data obtained were analyzed using two-way ANOVA, Tukey test and t test (_ = .05). To evaluate the percent occlusal force obtained from centric occlusal contacts, the T-Scan III system was used. The centric occlusal contacts were measured, before of first microwave disinfection (baseline) and after each week of disinfection, using pressure-sensitive sheets and studied in T-Scan software. The occlusal data... (Complete abstract click electronic access below)
14

Avaliação in vitro das variações posicionais da cabeça da mandíbula na fossa articular decorrentes da alteração dimensional de resinas acrílicas para base de prótese total submetidas a diferentes técnicas de processamento / In vitro evaluation of changes in the position of the mandibular condyle in consequence of dimensional changes in denture base acrylic resins submitted to different processing methods

Guarnieri, Tatiana de Carvalho 11 September 2006 (has links)
Este estudo teve o objetivo de avaliar in vitro a influência da alteração dimensional de resinas acrílicas para base de prótese total submetidas a diferentes formas de processamento sobre a posição da cabeça da mandíbula, buscando estabelecer uma possível relação com a etiologia das disfunções crânio-mandibulares nos pacientes usuários desse tipo de prótese. Foram duas etapas: a primeira parte enfocou o papel do tipo de prensa (Getom ou de cozimento) e da força de prensagem para fechamento da mufla (1000 ou 1500 kgf) utilizados no processamento de duas resinas: Lucitone 550 e QC–20 e somente da força de prensagem para a resina Acron MC. Já a segunda parte do estudo teve o intuito de avaliar a influência dos ciclos de polimerização curtos e longos na alteração dimensional de cinco resinas: as mesmas três da primeira parte, além da Clássico e Ondacryl. As próteses superiores acrilizadas foram remontadas em articulador totalmente ajustável, tendo como referência a posição de máxima intercuspidação (MIC). Nessa posição de maior estabilidade oclusal, foi vazado gesso tipo IV no espaço entre as esferas condilares do articulador e as paredes dos estojos condilares. Após a cristalização, esses corpos-de-prova de gesso foram removidos do estojo condilar e suas dimensões medidas e submetidas à análise estatística por meio de um modelo de análise de variância com medidas repetidas que permitiu concluir que houve variações na posição da “cabeça da mandíbula" em 625 das 630 medidas efetuadas; as médias de movimentação condilar variaram de 0,118 (DP = 0,0968) a 1,956 mm (DP = 0,414) e ocorreram principalmente no sentido posterior do lado esquerdo; na maioria dos casos em que a força de prensagem agiu como fator devariação, os deslocamentos obtidos com 1500 kgf foram menores do que aqueles obtidos com 1000 kgf; nos casos em que o tipo de prensa agiu como fator de variação, ora os menores deslocamentos foram obtidos com a prensa de cozimento, ora com a Getom; o ciclo empregado na polimerização não influenciou significativamente na estabilidade dimensional das próteses totais e a única diferença encontrada envolveu a resina Clássico, que levou aos maiores deslocamentos no sentido posterior do lado esquerdo. / The purpose of this study was to evaluate in vitro the influence of dimensional changes in denture base acrylic resins submitted to different processing methods on the position of the mandibular condyle. This was done to establish a relation between these dimensional changes and the etiology of temporomandibular disorders in complete denture wearers. This research was divided into two parts. The first part focused on the type of press (conventional water bath or Getom), on the pressing force for flask closure (1000 or 1500 kgf) when processing Lucitone 550 and QC-20 resins, and on the pressing force when processing Acron MC resin. The purpose of the second part was to evaluate the influence of polymerization time on the dimensional stability of five resins, namely Lucitone 550, QC-20, Acron MC, Clássico and Ondacryl. The polymerized upper prostheses were remounted on a fully adjustable articulator, using the maximal intercuspal position (MIP) as reference. Type IV dental stone was poured into the space between the condylar spheres and the condylar walls. After the dental stone dried, the samples were removed from the articulator and their dimensions were measured and submitted to analysis of variance with repeated measures. The following conclusions were drawn: 625 from 630 measurements done showed changes in the position of the “mandibular condyle" and mean values for condylar movement ranged from 0.118 (SD = 0.0968) to 1.956 mm (SD = 0.414) and occurred mainly in the posterior direction on the left side; in most cases where the pressing force influenced the condylar position, the changes were smaller in 1500 kgf group than in the 1000 kgf group; in the cases where the type of press influenced the changes in condylar position, the smallest values were found in both groups, sometimes with Getom and other times with conventional water bath press; polymerization time did not significantly affect the dimensional stability of the dentures and the greatest changes occurred in the posterior direction on the left side with Clássico resin.
15

Incorporação de ácido metacrílico em resinas acrílicas para base de prótese / Incorporation of methacrylic acid in denture base acrylic resins

Azevedo, Alessandra Miranda de 30 June 2009 (has links)
A resina acrílica para base de próteses removíveis é capaz de aderir Candida spp. sobre sua superfície, possibilitando o aparecimento das estomatites protéticas. Um fator importante para essa aderência é a hidrofobicidade do polímero. Assim, a adição de radicais hidrofílicos à resina acrílica tem potencial de torná-la menos suscetível à formação de biofilmes, e merece ser investigado. O objetivo deste projeto foi avaliar os efeitos da copolimerização do ácido metacrílico sobre aderência microbiana e propriedades físicas em um material à base de polimetil metacrilato para base de próteses removíveis. Para os ensaios com a resina acrílica, espécimes de diferentes formatos foram divididos em grupos, conforme a concentração do ácido metacrílico, em volume, na porção líquida da resina (A: 0%; B: 10%; C: 20%, D:50%). A aderência de Candida albicans foi avaliada por meio da contagem de unidades formadoras de colônia (UFC) aderidas sobre os espécimes mantidos em caldo de cultura. Também foi estudadas a dureza Vickers, a resistência flexural, a rugosidade e a estabilidade de cor. Os grupos foram descritos por média ± desvios padrão e comparados, dentro de cada variável, por meio de ANOVA, com &alpha; = 0,05. No caso da aderência de C. albicans, transformação em log10 foi realizada antes da análise. Como resultado desse estudo, não foi possível observar diferenças na aderência de C. albicans com a adição do ácido metacrílico à resina acrílica (A: 5,0 ± 0.4, B: 5,0 ± 0.4, C: 5.2 ± 0.6 e D: 5.2 ± 0.3 log10(UFC)). Redução significante foi encontrada para os valores de dureza, onde os valores (em VHN) foram A: 19,0 ± 1,4A, B: 19,6 ± 1,3A, C: 19,6 ± 0,9A e D: 14,2 ± 0,6B. Não houve diferença significante para o teste de resistência flexural (A: 96,32 ± 8,25, B: 97,65 ± 6,11, C: 102,43 ± 8,61 e D: 106,34 ± 13,69 MPa); no entanto foi observada redução na rugosidade superficial com o aumento da concentração do ácido (A: 0,26 ± 0,05A, B: 0,17 ± 0,01B, C: 0,18 ± 0,03B e D: 0,13 ± 0,03C &micro;m). Conclui-se que a copolimerização do ácido metacrílico em resina para base protética proporcionou mudanças nas propriedades físicas do material, com melhora na rugosidade, porém menor dureza. A aderência de C. albicans não sofreu interferência; futuros testes com outras espécies e na presença de proteínas salivares devem ser realizados a fim de determinar se a adição do ácido realmente possui potencial clínico. / Acrylic resins for denture base play an important role as reservoirs of micro-organisms, by increasing the risk of Candida ssp. colonization which is implicated in the pathogenesis of associated stomatitis. An important factor for this adherence is the polymer hydrophobicity. Thus, incorporation of polar radicals in the polymer could increase its hydrophylia, reducing this adherence. The main purpose of the present study was to investigate the antifungal activity of a denture base resin incorporating the methacrylic acid (MA) against Candida albicans by the counting of adherent cells and its effect on hardness, roughness and flexural strength of the material. 32 circular (14x4mm), 40 rectangular (65x10x3.3mm) and 40 square-shaped (10x10x3mm) specimens were divided into four groups, according to the concentration of MA substituted into the monomer component of a heat-polymerized acrylic resin (Lucitone 550), as follows: 0% (Control), 10%, 20% and 50% (v/v). Hardness was assessed by a hardness tester equipped with a Vickers diamond penetrator. A surface roughness tester was used to measure the surface roughness of the specimens, and a flexural strength testing was carried out on a universal testing machine. Variables were analyzed by ANOVA/Tukey\'s test (&alpha;=.05). Colonies were counted for each plated specimen and the colony-forming units per milliliter (CFU/mL) were then calculated. CFU/mL values for each concentration were compared by means of ANOVA/Tukey test after logarithmic (log 10) transformation (&alpha;=.05). A significant difference was found for hardness values (19.0±1.4A, 19.6±1.3A, 19.6±0.9A, 14.2±0.6B) VHN. Surface roughness values decreased with MA concentration increase (0.26±0.05A, 0.17±0.01AB, 0.18±0.03AB, 0.13±0.03B &micro;m). No significant difference was found for flexural strengh (96.3±8.3A, 97.7±6.1A, 102.4±8.6A, 106.3±13.7A MPa) and among the four groups for the adherence assay (A: 5,0 ± 0.4, B: 5,0 ± 0.4, C: 5.2 ± 0.6 e D: 5.2 ± 0.3 log10 (CFU). For the tested acrylic resin, the addition of MA in the concentration of 50% reduced its hardness. Thus, the presence of MA around this concentration inside the monomer may compromise the tested material structure. Although MA didnt lower the flexural strength, regardless of the concentration, the values for surface roughness reduced as MA concentration increased, suggesting that MA addition may improve the acrylic resin texture, leading to less biofilm accumulation. The adherence of C. albicans was not influenced by the presence of MA. Future tests with other microorganisms and salivary proteins should be carried out to determine if this incorporation has a clinical potencial to be used.
16

Análise das propriedades biológicas de um monômero antimicrobiano para aplicação em prótese dentária / Biological properties of an antimicrobial monomer for application in prosthodontics

Regis, Romulo Rocha 11 January 2010 (has links)
A resina acrílica para base de próteses removíveis é capaz de acumular biofilme e assim favorecer o aparecimento de diversos problemas na cavidade bucal dos usuários de próteses. A imobilização de um agente antisséptico na matriz polimérica tem potencial preventivo frente a esse acúmulo, mas necessita de maior investigação. O objetivo deste estudo foi avaliar as propriedades biológicas do brometo de metacriloiloxiundecilpiridínio (MUPB), um composto antisséptico capaz de copolimerizar-se com as resinas acrílicas. Foram determinadas as concentrações inibitória e fungicida/bactericida mínimas (CIM, CFM/CBM) do MUPB frente às espécies Candida albicans, Candida dubliniensis, Candida glabrata, Lactobacillus casei, Staphylococcus aureus e Streptococcus mutans, em comparação ao cloreto de cetilpiridínio (CCP). A seguir, investigou-se a citotoxicidade do MUPB em fibroblastos, comparando-o com o metil metacrilato (MMA). A avaliação da atividade antimicrobiana de diferentes concentrações do MUPB em massa (0, 0,3% e 0,6%) incorporado em uma resina acrílica termopolimerizável para base de próteses foi realizada por meio de testes de difusão em disco e quantificação de unidades formadoras de colônia (UFC) aderidas à resina após contato com suspensões de cada micro-organismo. A adesão microbiana também foi avaliada por microscopia eletrônica de varredura. Comparações entre o MUPB e as demais substâncias, bem como entre as concentrações incorporadas na resina, foram realizadas com &alpha;=0,05. O MUPB apresentou CIM inferior ao CCP para C. dublinienses e S. mutans (P=0,046 e 0,043, respectivamente). Para as demais espécies, as diferenças não foram significantes. Para a CFM/CBM, só foi encontrada diferença significante para C. albicans (P=0,046). O MUPB não polimerizado mostrou-se em torno de 20 vezes mais citotóxico que o MMA. Independente da concentração incorporada e da espécie, não houve formação de halo de inibição em torno dos espécimes. A incorporação do MUPB só influenciou na adesão de C. albicans (P=0,003), com menores contagens de UFC para o grupo com 0,6%. Conclui-se que o MUPB não polimerizado tem capacidade antimicrobiana próxima à do CCP, e alta citotoxicidade, se comparado ao MMA. A atividade antimicrobiana, após incorporação em uma resina acrílica para base de prótese, não depende de sua eluição, porém apresentou-se restrita à C. albicans. / Acrylic resins for removable denture base are capable of accumulating biofilm and thus favor the appearance of various problems in the edentulous oral cavity. An antiseptic agent immobilized within the polymeric matrix has a preventive potential against this accumulation, but requires further investigation. The aim of this study was to evaluate the biological properties of methacryloyloxyundecylpyridinium bromide (MUPB), an antiseptic monomer capable of copolymerizing with acrylic resins. The minimum inhibitory and fungicidal/bactericidal concentrations (MIC, MFC/MBC) of MUPB were determined against the species Candida albicans, Candida dubliniensis, Candida glabrata, Lactobacillus casei, Staphylococcus aureus and Streptococcus mutans, in comparison with cetylpyridinium chloride (CCP). After this, the cytotoxicity of MUPB was investigated in fibroblasts, compared with methyl methacrylate (MMA). The antimicrobial activity of different concentrations of MUPB (0, 0.3% and 0.6% w/w) incorporated into a heat polymerized denture base acrylic resin was evaluated by means of disk diffusion tests, and the CFUs adhered to the resin after contact with suspensions of each microorganism were quantified. Microbial adhesion was also evaluated by scanning electron microscopy. Comparisons were made between MUPB and the other substances, as well as between the concentrations incorporated into the resin (&alpha;=.05). MUPB presented a lower MIC than CCP for C. dubliniensis and S. mutans (P=.046 and .043, respectively). For the other species, the differences were not significant. For MFC or MBC, significant difference was found only for C. albicans (P=.046). Non polymerized MUPB was shown to be 20 times more cytotoxic than MMA. Irrespective of the concentration incorporated and the species, there was no growth of inhibition halo around the specimens. The incorporation of MUPB only influenced the adhesion of C. albicans (P=.003), with lower CFU counts for the group with the concentration of 0.6%. It was concluded that non polymerized MUPB has an antimicrobial capacity close to that of CCP, and high cytotoxicity when compared with MMA. The antimicrobial activity after incorporation within a denture base acrylic resin did not depend on its elution, but was shown to be restricted to C. albicans.
17

Análise das propriedades biológicas de um monômero antimicrobiano para aplicação em prótese dentária / Biological properties of an antimicrobial monomer for application in prosthodontics

Romulo Rocha Regis 11 January 2010 (has links)
A resina acrílica para base de próteses removíveis é capaz de acumular biofilme e assim favorecer o aparecimento de diversos problemas na cavidade bucal dos usuários de próteses. A imobilização de um agente antisséptico na matriz polimérica tem potencial preventivo frente a esse acúmulo, mas necessita de maior investigação. O objetivo deste estudo foi avaliar as propriedades biológicas do brometo de metacriloiloxiundecilpiridínio (MUPB), um composto antisséptico capaz de copolimerizar-se com as resinas acrílicas. Foram determinadas as concentrações inibitória e fungicida/bactericida mínimas (CIM, CFM/CBM) do MUPB frente às espécies Candida albicans, Candida dubliniensis, Candida glabrata, Lactobacillus casei, Staphylococcus aureus e Streptococcus mutans, em comparação ao cloreto de cetilpiridínio (CCP). A seguir, investigou-se a citotoxicidade do MUPB em fibroblastos, comparando-o com o metil metacrilato (MMA). A avaliação da atividade antimicrobiana de diferentes concentrações do MUPB em massa (0, 0,3% e 0,6%) incorporado em uma resina acrílica termopolimerizável para base de próteses foi realizada por meio de testes de difusão em disco e quantificação de unidades formadoras de colônia (UFC) aderidas à resina após contato com suspensões de cada micro-organismo. A adesão microbiana também foi avaliada por microscopia eletrônica de varredura. Comparações entre o MUPB e as demais substâncias, bem como entre as concentrações incorporadas na resina, foram realizadas com &alpha;=0,05. O MUPB apresentou CIM inferior ao CCP para C. dublinienses e S. mutans (P=0,046 e 0,043, respectivamente). Para as demais espécies, as diferenças não foram significantes. Para a CFM/CBM, só foi encontrada diferença significante para C. albicans (P=0,046). O MUPB não polimerizado mostrou-se em torno de 20 vezes mais citotóxico que o MMA. Independente da concentração incorporada e da espécie, não houve formação de halo de inibição em torno dos espécimes. A incorporação do MUPB só influenciou na adesão de C. albicans (P=0,003), com menores contagens de UFC para o grupo com 0,6%. Conclui-se que o MUPB não polimerizado tem capacidade antimicrobiana próxima à do CCP, e alta citotoxicidade, se comparado ao MMA. A atividade antimicrobiana, após incorporação em uma resina acrílica para base de prótese, não depende de sua eluição, porém apresentou-se restrita à C. albicans. / Acrylic resins for removable denture base are capable of accumulating biofilm and thus favor the appearance of various problems in the edentulous oral cavity. An antiseptic agent immobilized within the polymeric matrix has a preventive potential against this accumulation, but requires further investigation. The aim of this study was to evaluate the biological properties of methacryloyloxyundecylpyridinium bromide (MUPB), an antiseptic monomer capable of copolymerizing with acrylic resins. The minimum inhibitory and fungicidal/bactericidal concentrations (MIC, MFC/MBC) of MUPB were determined against the species Candida albicans, Candida dubliniensis, Candida glabrata, Lactobacillus casei, Staphylococcus aureus and Streptococcus mutans, in comparison with cetylpyridinium chloride (CCP). After this, the cytotoxicity of MUPB was investigated in fibroblasts, compared with methyl methacrylate (MMA). The antimicrobial activity of different concentrations of MUPB (0, 0.3% and 0.6% w/w) incorporated into a heat polymerized denture base acrylic resin was evaluated by means of disk diffusion tests, and the CFUs adhered to the resin after contact with suspensions of each microorganism were quantified. Microbial adhesion was also evaluated by scanning electron microscopy. Comparisons were made between MUPB and the other substances, as well as between the concentrations incorporated into the resin (&alpha;=.05). MUPB presented a lower MIC than CCP for C. dubliniensis and S. mutans (P=.046 and .043, respectively). For the other species, the differences were not significant. For MFC or MBC, significant difference was found only for C. albicans (P=.046). Non polymerized MUPB was shown to be 20 times more cytotoxic than MMA. Irrespective of the concentration incorporated and the species, there was no growth of inhibition halo around the specimens. The incorporation of MUPB only influenced the adhesion of C. albicans (P=.003), with lower CFU counts for the group with the concentration of 0.6%. It was concluded that non polymerized MUPB has an antimicrobial capacity close to that of CCP, and high cytotoxicity when compared with MMA. The antimicrobial activity after incorporation within a denture base acrylic resin did not depend on its elution, but was shown to be restricted to C. albicans.
18

Incorporação de ácido metacrílico em resinas acrílicas para base de prótese / Incorporation of methacrylic acid in denture base acrylic resins

Alessandra Miranda de Azevedo 30 June 2009 (has links)
A resina acrílica para base de próteses removíveis é capaz de aderir Candida spp. sobre sua superfície, possibilitando o aparecimento das estomatites protéticas. Um fator importante para essa aderência é a hidrofobicidade do polímero. Assim, a adição de radicais hidrofílicos à resina acrílica tem potencial de torná-la menos suscetível à formação de biofilmes, e merece ser investigado. O objetivo deste projeto foi avaliar os efeitos da copolimerização do ácido metacrílico sobre aderência microbiana e propriedades físicas em um material à base de polimetil metacrilato para base de próteses removíveis. Para os ensaios com a resina acrílica, espécimes de diferentes formatos foram divididos em grupos, conforme a concentração do ácido metacrílico, em volume, na porção líquida da resina (A: 0%; B: 10%; C: 20%, D:50%). A aderência de Candida albicans foi avaliada por meio da contagem de unidades formadoras de colônia (UFC) aderidas sobre os espécimes mantidos em caldo de cultura. Também foi estudadas a dureza Vickers, a resistência flexural, a rugosidade e a estabilidade de cor. Os grupos foram descritos por média ± desvios padrão e comparados, dentro de cada variável, por meio de ANOVA, com &alpha; = 0,05. No caso da aderência de C. albicans, transformação em log10 foi realizada antes da análise. Como resultado desse estudo, não foi possível observar diferenças na aderência de C. albicans com a adição do ácido metacrílico à resina acrílica (A: 5,0 ± 0.4, B: 5,0 ± 0.4, C: 5.2 ± 0.6 e D: 5.2 ± 0.3 log10(UFC)). Redução significante foi encontrada para os valores de dureza, onde os valores (em VHN) foram A: 19,0 ± 1,4A, B: 19,6 ± 1,3A, C: 19,6 ± 0,9A e D: 14,2 ± 0,6B. Não houve diferença significante para o teste de resistência flexural (A: 96,32 ± 8,25, B: 97,65 ± 6,11, C: 102,43 ± 8,61 e D: 106,34 ± 13,69 MPa); no entanto foi observada redução na rugosidade superficial com o aumento da concentração do ácido (A: 0,26 ± 0,05A, B: 0,17 ± 0,01B, C: 0,18 ± 0,03B e D: 0,13 ± 0,03C &micro;m). Conclui-se que a copolimerização do ácido metacrílico em resina para base protética proporcionou mudanças nas propriedades físicas do material, com melhora na rugosidade, porém menor dureza. A aderência de C. albicans não sofreu interferência; futuros testes com outras espécies e na presença de proteínas salivares devem ser realizados a fim de determinar se a adição do ácido realmente possui potencial clínico. / Acrylic resins for denture base play an important role as reservoirs of micro-organisms, by increasing the risk of Candida ssp. colonization which is implicated in the pathogenesis of associated stomatitis. An important factor for this adherence is the polymer hydrophobicity. Thus, incorporation of polar radicals in the polymer could increase its hydrophylia, reducing this adherence. The main purpose of the present study was to investigate the antifungal activity of a denture base resin incorporating the methacrylic acid (MA) against Candida albicans by the counting of adherent cells and its effect on hardness, roughness and flexural strength of the material. 32 circular (14x4mm), 40 rectangular (65x10x3.3mm) and 40 square-shaped (10x10x3mm) specimens were divided into four groups, according to the concentration of MA substituted into the monomer component of a heat-polymerized acrylic resin (Lucitone 550), as follows: 0% (Control), 10%, 20% and 50% (v/v). Hardness was assessed by a hardness tester equipped with a Vickers diamond penetrator. A surface roughness tester was used to measure the surface roughness of the specimens, and a flexural strength testing was carried out on a universal testing machine. Variables were analyzed by ANOVA/Tukey\'s test (&alpha;=.05). Colonies were counted for each plated specimen and the colony-forming units per milliliter (CFU/mL) were then calculated. CFU/mL values for each concentration were compared by means of ANOVA/Tukey test after logarithmic (log 10) transformation (&alpha;=.05). A significant difference was found for hardness values (19.0±1.4A, 19.6±1.3A, 19.6±0.9A, 14.2±0.6B) VHN. Surface roughness values decreased with MA concentration increase (0.26±0.05A, 0.17±0.01AB, 0.18±0.03AB, 0.13±0.03B &micro;m). No significant difference was found for flexural strengh (96.3±8.3A, 97.7±6.1A, 102.4±8.6A, 106.3±13.7A MPa) and among the four groups for the adherence assay (A: 5,0 ± 0.4, B: 5,0 ± 0.4, C: 5.2 ± 0.6 e D: 5.2 ± 0.3 log10 (CFU). For the tested acrylic resin, the addition of MA in the concentration of 50% reduced its hardness. Thus, the presence of MA around this concentration inside the monomer may compromise the tested material structure. Although MA didnt lower the flexural strength, regardless of the concentration, the values for surface roughness reduced as MA concentration increased, suggesting that MA addition may improve the acrylic resin texture, leading to less biofilm accumulation. The adherence of C. albicans was not influenced by the presence of MA. Future tests with other microorganisms and salivary proteins should be carried out to determine if this incorporation has a clinical potencial to be used.
19

Avaliação clínica da estabilidade dimensional de próteses totais submetidas à desinfecção por microondas /

Basso, Michael Frederico Manzolli. January 2009 (has links)
Resumo: A energia por microondas tem sido recomendada para desinfetar próteses totais. Entretanto, os ciclos de desinfecção podem afetar a estabilidade dimensional das bases de próteses. Assim, o objetivo deste estudo clínico foi avaliar o efeito de dois protocolos de desinfecção por microondas na estabilidade dimensional de próteses totais, analisando a estabilidade dimensional linear, o percentual de força oclusal obtido a partir dos contatos oclusais cêntricos e as ocorrências clínicas. Foram confeccionadas próteses totais para quarenta pacientes totalmente edêntulos. Todas as próteses foram prensadas com a resina Lucitone 550. Após a colocação, aguardou-se 30 dias para submeter as próteses às condições experimentais como a seguir: Grupo 1 (G1)- 20 pacientes tiveram as próteses maxilares submetidas a desinfecção por microondas (650 W / 3 minutos), uma vez por semana, durante 4 semanas. Grupo 2 (G2)- 20 pacientes tiveram as próteses maxilares submetidas a desinfecção por microondas (650 W / 3 minutos), três vezes por semana, durante 4 semanas. Para avaliar a estabilidade dimensional linear, mensurações foram realizadas entre quatro pontos de referência (primeiros pré-molares e segundos molares bilateralmente) antes da primeira desinfecção por microondas (baseline) e após cada semana de desinfecção. Um software foi utilizado para mensurar as distâncias entre os pontos de referência a partir de fotografias padronizadas. As dimensões médiolateral e anteroposterior e a área foram calculadas. Os dados foram analisados pelos testes ANOVA two-way, Tukey e t-Student (_=0,05). O sistema T-Scan III foi utilizado para avaliar o percentual de força oclusal obtido a partir dos contatos oclusais cêntricos. Os contatos oclusais cêntricos foram capturados, antes da primeira desinfecção por microondas (baseline) e após cada semana de desinfecção, por meio... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Microwave energy has been recommended for disinfecting complete dentures. However, the microwave disinfection cycles may affect the dimensional stability of denture bases. Therefore, the purpose of this clinical study was to evaluate the effect of two microwave disinfection protocols on the dimensional stability of complete dentures, analyzing the linear dimensional stability, the percent occlusal force obtained from centric occlusal contacts and the clinical events. Complete dentures were constructed for forty totally edentulous patients. All dentures were conventionally processed with heat-polymerized acrylic resin (Lucitone 550). After insertion of complete dentures, it was expected 30 days to submit the dentures to the experimental conditions as follows: Group 1 (G1)- 20 patients had the maxillary complete dentures submitted to microwave disinfection (650 W/ 3 minutes), once a week, for four weeks. Group 2 (G2)- 20 patients had the maxillary complete dentures submitted to microwave disinfection (650 W/ 3 minutes), three times a week, for four weeks. To evaluate the linear dimensional stability, measurements were taken across four reference points (first premolars and second molars bilaterally) before of first microwave disinfection (baseline) and after each week of disinfection. Software was used to measure distances between reference points from standardized photographs. Mediolateral and anteroposterior dimensions and area between reference points were calculated. The dimensional data obtained were analyzed using two-way ANOVA, Tukey test and t test (_ = .05). To evaluate the percent occlusal force obtained from centric occlusal contacts, the T-Scan III system was used. The centric occlusal contacts were measured, before of first microwave disinfection (baseline) and after each week of disinfection, using pressure-sensitive sheets and studied in T-Scan software. The occlusal data... (Complete abstract click electronic access below) / Orientador: Eunice Teresinha Giampaolo / Coorientador: Marco Antonio Compagnoni / Banca: Raphael Freitas de Souza / Banca: Claudia Helena Lovato da Silva / Banca: Ana Claudia Pavarina / Banca: João Neudenir Arioli Filho / Doutor
20

Avaliação in vitro das variações posicionais da cabeça da mandíbula na fossa articular decorrentes da alteração dimensional de resinas acrílicas para base de prótese total submetidas a diferentes técnicas de processamento / In vitro evaluation of changes in the position of the mandibular condyle in consequence of dimensional changes in denture base acrylic resins submitted to different processing methods

Tatiana de Carvalho Guarnieri 11 September 2006 (has links)
Este estudo teve o objetivo de avaliar in vitro a influência da alteração dimensional de resinas acrílicas para base de prótese total submetidas a diferentes formas de processamento sobre a posição da cabeça da mandíbula, buscando estabelecer uma possível relação com a etiologia das disfunções crânio-mandibulares nos pacientes usuários desse tipo de prótese. Foram duas etapas: a primeira parte enfocou o papel do tipo de prensa (Getom ou de cozimento) e da força de prensagem para fechamento da mufla (1000 ou 1500 kgf) utilizados no processamento de duas resinas: Lucitone 550 e QC–20 e somente da força de prensagem para a resina Acron MC. Já a segunda parte do estudo teve o intuito de avaliar a influência dos ciclos de polimerização curtos e longos na alteração dimensional de cinco resinas: as mesmas três da primeira parte, além da Clássico e Ondacryl. As próteses superiores acrilizadas foram remontadas em articulador totalmente ajustável, tendo como referência a posição de máxima intercuspidação (MIC). Nessa posição de maior estabilidade oclusal, foi vazado gesso tipo IV no espaço entre as esferas condilares do articulador e as paredes dos estojos condilares. Após a cristalização, esses corpos-de-prova de gesso foram removidos do estojo condilar e suas dimensões medidas e submetidas à análise estatística por meio de um modelo de análise de variância com medidas repetidas que permitiu concluir que houve variações na posição da “cabeça da mandíbula” em 625 das 630 medidas efetuadas; as médias de movimentação condilar variaram de 0,118 (DP = 0,0968) a 1,956 mm (DP = 0,414) e ocorreram principalmente no sentido posterior do lado esquerdo; na maioria dos casos em que a força de prensagem agiu como fator devariação, os deslocamentos obtidos com 1500 kgf foram menores do que aqueles obtidos com 1000 kgf; nos casos em que o tipo de prensa agiu como fator de variação, ora os menores deslocamentos foram obtidos com a prensa de cozimento, ora com a Getom; o ciclo empregado na polimerização não influenciou significativamente na estabilidade dimensional das próteses totais e a única diferença encontrada envolveu a resina Clássico, que levou aos maiores deslocamentos no sentido posterior do lado esquerdo. / The purpose of this study was to evaluate in vitro the influence of dimensional changes in denture base acrylic resins submitted to different processing methods on the position of the mandibular condyle. This was done to establish a relation between these dimensional changes and the etiology of temporomandibular disorders in complete denture wearers. This research was divided into two parts. The first part focused on the type of press (conventional water bath or Getom), on the pressing force for flask closure (1000 or 1500 kgf) when processing Lucitone 550 and QC-20 resins, and on the pressing force when processing Acron MC resin. The purpose of the second part was to evaluate the influence of polymerization time on the dimensional stability of five resins, namely Lucitone 550, QC-20, Acron MC, Clássico and Ondacryl. The polymerized upper prostheses were remounted on a fully adjustable articulator, using the maximal intercuspal position (MIP) as reference. Type IV dental stone was poured into the space between the condylar spheres and the condylar walls. After the dental stone dried, the samples were removed from the articulator and their dimensions were measured and submitted to analysis of variance with repeated measures. The following conclusions were drawn: 625 from 630 measurements done showed changes in the position of the “mandibular condyle” and mean values for condylar movement ranged from 0.118 (SD = 0.0968) to 1.956 mm (SD = 0.414) and occurred mainly in the posterior direction on the left side; in most cases where the pressing force influenced the condylar position, the changes were smaller in 1500 kgf group than in the 1000 kgf group; in the cases where the type of press influenced the changes in condylar position, the smallest values were found in both groups, sometimes with Getom and other times with conventional water bath press; polymerization time did not significantly affect the dimensional stability of the dentures and the greatest changes occurred in the posterior direction on the left side with Clássico resin.

Page generated in 0.1228 seconds