Spelling suggestions: "subject:"dentures.material"" "subject:"fracturespartially""
81 |
Die Legierung alba als Kronen- und BrückenmaterialEssl, Ernst, January 1935 (has links)
Thesis (Doctoral)--Bayer. Ludwig-Maximilians-Universität München, 1935.
|
82 |
Avaliação de tratamentos de superfície em diferentes sistemas cerâmicos e seu efeito na resistência de união a um cimento resinosoRibeiro, João Gustavo Rabelo [UNESP] 03 March 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0
Previous issue date: 2005-03-03Bitstream added on 2014-06-13T19:16:51Z : No. of bitstreams: 1
ribeiro_jgr_me_arafo.pdf: 3291389 bytes, checksum: 7433b8057e44c506b548538c7a3e997e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar o efeito de três tratamentos superficiais na resistência de união de um cimento resinoso a três cerâmicas dentais: Duceram Plus (DP), IPS Empress II (IPS) e In-Ceram Alumina (INC), e analisar a topografia superficial dessas cerâmicas submetidas aos mesmos tratamentos superficiais. Para o teste de resistência de união foram confeccionadas 18 amostras de cada material (7,5mm de diâmetro x 3,0mm de espessura), incluídas em resina acrílica e polidas até lixa nº 600. As amostras foram divididas em três grupos: a) jateamento com partículas de óxido de alumínio de 50 æm; b) condicionamento com ácido fluorídrico 10%; c) associação de a e b. As amostras foram lavadas e secas. A área de adesão da cerâmica foi delimitada com matriz metálica perfurada (5,0mm de diâmetro e 3,0mm de espessura). Foi aplicado silano, adesivo e cimento resinoso Variolink II, fotoativado por 40 segundos. As amostras receberam 1000 ciclos térmicos de 5 a 55°C. O ensaio de cisalhamento foi realizado em máquina de ensaios MTS 810, com célula de carga de 10 kN e velocidade de 0,5 mm/min. Para a topografia superficial foram confeccionados um coping de IPS, um do INC e uma coroa de DP, seguindo as recomendações dos fabricantes. Cada coping ou coroa foi cortado com disco diamantado em quatro partes: uma delas não recebeu nenhum tratamento, e as demais receberam um dos tratamentos acima descritos. Fotomicrografias foram obtidas por meio de microscopia eletrônica de varredura e a análise foi feita de acordo com a característica da superfície. Pode-se concluir que: o tratamento associado não ofereceu vantagens em relação ao condicionamento ácido, para os materiais DP e IPS; para o INC o tratamento associado não ofereceu vantagens em relação ao jateamento. A DP e o IPS apresentaram resultados melhores em relação ao INC, independentemente dos tratamentos... / The aim of this study was to evaluate the effect of three surface treatments on the shear bond strength of a resin luting cement to three ceramics materials: Duceram Plus (DP), IPS Empress II (IPS) and In-Ceram Alumina (INC), and to assess its surface topography after these treatments. Eighteen specims were fabricated to each material (7,5 mm in diameter x 3,0 mm in thickness), embebed in acrylic resin and ground up to 600 grit. The specims were randomly divided into 3 groups of 6 specims: (a) airborne particle abrasion with 50 æm aluminum oxide; (b) 10% hydrofluoric acid etching; (c) a and b treatments. The specims were cleaned and dried. Silane, adhesive and resin luting cement Variolink were applied in 5,0 mm in diameter and 3,0 mm height to ceramic surface and then light cured. All specims were termocycled (1000, 5-55°C). The shear bond strength was then measured in a testing machine MTS 810, at a crosshead speed of 0,5 mm/min. To asses the surface topography, one coping each of IPS and INC, and a DP crown were fabricated following the manufacturer's instructions. Each coping or crown was sectioned into 4 equal parts by a diamond disk. One part didn't receive any treatment, and the others, received treatments as above described. Photomicrographs were obtained by a SEM, and the superficial characteristic was described. In conclusion, the associate treatment didn't offer advantages in relation to the acid etching, for DP and IPS; for INC the associate treatment didn't offer advantages in relation to the airborne. DP and IPS presented the best results, independently of the superficial treatments. The photomicrographs showed compatible correlation of the superficial characteristic with the bond strength values.
|
83 |
Sistemas CAD/CAM: avaliação da precisão de aquisição de dadosMello, Caroline Cantieri de [UNESP] 18 February 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:41Z (GMT). No. of bitstreams: 0
Previous issue date: 2014-02-18Bitstream added on 2015-03-03T12:06:08Z : No. of bitstreams: 1
000795787.pdf: 571234 bytes, checksum: f635d0ca5e8e957bf53c65ab8998057a (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Objetivo: O objetivo deste estudo foi avaliar a adaptação marginal de infraestruturas de próteses fixas confeccionadas pelo Sistema CAD/CAM com três diferentes sistemas de aquisição de dados. Material e Métodos: Confeccionaram-se 50 corpos de prova; Convencional (Ni-Cr) (n = 10), GI: iTero (n = 10), GII: CerecBluecam/fresadora industrial (n = 10), GIII: 3S (n = 10) e GIV: CerecBlueCam/Sirona (n = 10). Os corpos de prova foram numerados e randomizados, realizou-se análise da desadaptação marginal vertical. Resultados: A análise intra observador indicou que não houve diferença estatisticamente significante (teste t pareado, p = 0.822) no período antes e depois das análises. O sistema convencional (321 ?m) apresentou maior desadaptação quando comparado com o sistema CAD/CAM (89 ?m) (p<0.001). O sistema intra oral (iTero) apresentou menor índice de desadaptação marginal, quando comparado com o sistema extra oral (3S), (p<0.001). O sistema aberto apresentou maior índice de desadaptação marginal (114 ?m) quando comparado com intra oral (iTero), sendo p<0.001. Além disto, no sistema convencional, observou-se que os pré-molares apresentaram índice de desadaptação maior quando comparado (361 ?m) com o molar (283 ?m) (p<0.001), porém no sistema CAD/CAM não houve diferença estatisticamente significante na comparação de dentes pré-molares (93,7 ?m) e molares (84,9 ?m). Significância: O sistema CAD/CAM pode atuar mais favoravelmente, reduzindo o índice de desadaptação marginal, quando comparado com o sistema convencional de confecção de próteses dentárias. O sistema intra oral (iTero) comportou-se melhor quando comparado com os demais sistemas. / Objective: The aim of this study was to evaluate the marginal fit of frameworks produced by CAD/CAM systems with three different data acquisition. Material and Methods: We fabricated 50 frameworks: conventional (Ni-Cr) (n = 10), GI:iTero (n = 10), GII:CerecBluecam/industrial milling (n = 10), GIII:3S (n = 10), and GIV:CerecBlueCam/Sirona (n = 10). We numbered the specimens and analyzed them randomly. Results: Intra-observer analysis indicated no statistically significant difference (paired t-test, p = 0.822) before and after the analysis. The conventional system (321 ?m) showed greater misfit than the CAD/CAM (89 ?m) (p<0.001) system. The intraoral system (iTero) showed a lower rate of marginal misfit than the extra-oral system (3S), (p<0.001). The open system presented a higher marginal discrepancy (114 ?m) than intraoral (iTero), with p<0.001. Moreover, in the conventional system, premolars (361 ?m) showed a higher index of misfit than molars (283 ?m) (p<0.001), but for the CAD/CAM system, there was no statistically significant difference between premolars (93.7 ?m) and molars (84.9 ?m). Significance: The CAD/CAM system can to act more favorably reducing the rate of marginal discrepancy than the conventional impression system of dental prosthesis. The intra oral system (iTero) was better than other systems. / FAPESP: 11/06311-5
|
84 |
Análise do comportamento da cor de restaurações cerâmicas sem metal avaliadas por diferentes métodos: estudo clínico prospectivoMartini, Ana Paula [UNESP] 08 September 2015 (has links) (PDF)
Made available in DSpace on 2016-02-05T18:30:14Z (GMT). No. of bitstreams: 0
Previous issue date: 2015-09-08. Added 1 bitstream(s) on 2016-02-05T18:34:24Z : No. of bitstreams: 1
000857916.pdf: 3361545 bytes, checksum: 05e359e822d36e17b2cdd2f6036cc13f (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Introdução: O processo de interpretação da cor em restaurações cerâmicas delgadas pré e pós-tratamento é um desafio. Os métodos de avaliação dos resultados são diversos e a literatura não é clara em apontar o mais eficaz e eficiente. A questão é ainda mais relevante diante da variação do cimento resinoso utilizado. Proposição: Após variar o tipo de cimento resinoso utilizado, o objetivo deste estudo foi avaliar o comportamento da cor de restaurações cerâmicas em dentes com demanda estética, ao longo de 1 ano após o tratamento, com o auxílio de diferentes métodos de acompanhamento (espectrofotômetro, fotografias, vídeos e avaliação clínica) em um estudo clínico longitudinal e prospectivo. Materiais e Métodos: Foram selecionados 28 pacientes, perfazendo um total de 204 dentes restaurados (89 facetas laminadas, 57 coroas totais ou parciais e 58 lentes de contato). 76 restaurações foram cimentadas com Rely X veneer, 71 com Variolink veneer e 57 com Rely X U200. Foram realizadas mensurações de cor com espectrofotômetro, fotografias digitais e vídeos gravados no decorrer do tratamento e em controles periódicos (inicial, 30 dias, 180 dias e 1 ano após a cimentação). Grupos formados por observadores externos (pacientes, alunos de 1º e último ano de graduação, pós-graduandos e especialistas) avaliaram, aleatoriamente, as imagens obtidas inicialmente e ao final do tratamento, segundo perguntas sobre a satisfação ou não com o resultado estético do caso. Resultados: Os dados obtidos com o espectrofotômetro foram submetidos a testes estatísticos que revelaram diferença significativa apenas entre os tempos avaliados, contudo, para todos os tipos de restauração foi observada estabilidade de cor após, no máximo, 180 dias da cimentação. Não houve diferença estatística entre a satisfação dos diferentes grupos... / Introduction: The process of interpretation of color in thin ceramic restorations pre- and post-treatment is challenging. The evaluation methods of the results are diverse and literature is not clear in pointing out the most effective method. The question is even more relevant given the variation of the resin cement used. Purpose: After changing the type of resin cement used, the aim of this study was to evaluate the color behavior of ceramic restorations in teeth with aesthetic demand, over 1 year after treatment, with the help of different monitoring methods (spectrophotometer, photographs, videos and clinical assessment) in a longitudinal and prospective study. Materials and Methods: 28 patients were selected, for a total of 204 restored teeth (89 veneers, 57 crowns and 58 contact lenses). 76 restorations were cemented with Rely X veneer, 71 with Variolink veneer and 57 with Rely X U200. Color measurements were made with a spectrophotometer, digital photos and videos taken during treatment and periodic controls (initial, 30 days, 180 days and 1 year after cementation). Groups formed by outside observers (patients, students of 1st and last year of undergraduate, graduate students, and experts) evaluated, randomly, images obtained initially and after treatment, according to questions on satisfaction or not with the aesthetic outcome of the case. Results: The data obtained with the spectrophotometer were subjected to statistical tests which showed a significant difference only between the time periods; however, for all types of restoration, color stability was observed after a maximum of 180 days after cementation. There was no statistical difference between the satisfaction of different groups of outsiders observers with the aesthetic result of the cases for both the photos and for videos, although they videos have obtained the highest... / FAPESP: 12/14574-6
|
85 |
Avaliação da precisão de aquisição de dados nos Sistemas CAD/CAM: desadaptação marginal horizontalLopes, Leonardo Ferreira de Toledo Piza [UNESP] 23 February 2015 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:34:29Z (GMT). No. of bitstreams: 0
Previous issue date: 2015-02-23. Added 1 bitstream(s) on 2015-06-18T12:48:45Z : No. of bitstreams: 1
000831388.pdf: 562171 bytes, checksum: e080c07a229e0894fa23757920f53d4c (MD5) / Objetivo: O objetivo deste estudo foi avaliar a adaptação marginal horizontal de infraestruturas de próteses fixas confeccionadas pelo sistema CAD-CAM com três diferentes sistemas de aquisição de dados. Material e Métodos: Foram confeccionados 50 corpos de prova divididos em 5 grupos, sendo eles, Convencional (Ni-Cr); GI: iTero; GII: CerecBluecam/fresadora industrial; GIII: 3S; GIV: CerecBluecam/ fresadora Sirona, todos com n=10. Os corpos de prova foram numerados e randomizados, realizou-se análise da desadaptação marginal horizontal, esta dividida em positiva para sobre-contorno e negativa para subcontorno. Resultados: A análise intra-examinador revelou não haver diferença estatística entre os dois períodos de análise (t pareado=0.019; p=0.985). Em relação as desadaptações de sobre-contorno (valores positivos) podemos analisar que o grupo controle (Convencional) apresentou estatisticamente (p <0.001) menores valores de desadaptação (82 μm) quando comparado com o grupo CAD/CAM (144 μm). Ao comparar o sistema intra/extra-oral pode-se observar que o grupo intra-oral (iTero) apresentou melhores resultados, sendo essa diferença estatisticamente significante (p <0.001) que o extra-oral (3s). Já avaliando a diferença entre um sistema aberto com um fechado foi observado que o sistema aberto apresentou estatisticamente menor desadaptação (p<0.001). Quando avaliou-se a quebra de um sistema fechado (Cerec BlueCam) para sua fresagem a nível industrial notou-se que há desvantagens em tal procedimento, pois houve estatisticamente maiores desadaptações no grupo da quebra do sistema (p<0.001). Em contra partida nenhuma diferença estatisticamente significante foi encontrada em todas as análises quando se comparou desadaptação por sub contorno. Significância: Avaliando a discrepância... / Objective: The aim of this study was to evaluate the horizontal marginal fit of frameworks produced by CAD/CAM systems with 3 different data acquisition. Material and Methods: We fabricated 50 frameworks divided into 5 groups, Conventional (Ni- Cr); GI: iTero; GII: CerecBluecam/industrial milling; GIII: 3S; GIV: CerecBluecam/Sirona, all with n = 10. We numbered the specimens and analyzed them randomly. Results: Intra-observer analisys indicated no statistically significant difference (paired t-test=0.019; p=0.985). In relation to the overextended horizontal marginal discrepancy (Positive Values) can analyze that the Control group (Conventional) had significantly (p < 0.001) minor discrepancy values (82 μm) when compared to the CAD / CAM group (144 μm). When comparing the systems intra/extra oral can be appreciated that the intra oral group (Itero) presented statistically best results when comparing(p < 0.001) that the extra oral ( 3s ). Evaluating the difference between the open system with closed was observed that the open system had statistically smaller misfit (p < 0.001). Evaluating the broke of a closed system (Cerec Bluecam) your industrial milling had statistically (p < 0.001) worse adaptation when compared to the laboratorial milling. About the under extended marginal discrepancy, in all analysis there was not found statistically significant difference. Significance: Assessing the horizontal marginal discrepancy was possible to note that in relation to the overextended the control group had statistically better results than the CAD/CAM systems, however the Cerec Bluecam system by sirona milling had better results than all CAD/CAM system and also the control group. There was no difference between the under extended misfit and all analysis
|
86 |
Avaliação da resistência flexural de materiais restauradores provisórios resinosos /Machado, Carolina Ellen Spínola January 2018 (has links)
Orientador: Andréa Abi Rached Dantas / Resumo: O objetivo do estudo foi avaliar a resistência flexural de materiais restauradores resinosos provisórios (Systemp Onlay, Bifix Temp, Provyl Master F, Fill Magic e Clip F) após a fotopolimerização com sistema de fotoativação LED-laser: Radii-Cal (SDI, São Paulo, SP, BR). A resistência flexural demonstrada pelos materiais restauradores provisórios Provi Master F (Wilcos), Systemp (Ivoclair) e Fill Magic (Coltene) foi similar (p >0,05) e maior que a demonstrada pelos materiais restauradores BiFix (Voco) e Clip F (Voco) (p < 0,05). Por outro lado, a resistência flexural apresentada pelo BiFix e Clip F foi semelhante entre si (p > 0.05). Concluimos assim que os materiais Provi Master F, Systemp e Fill Magic são materiais de melhor escolha quando necessitamos de uma resistência maior às forças oclusais. / Abstract: The objective of this study was to evaluate the flexural strength of temporary resin restorative materials (Systemp Onlay, Bifix Temp, Provyl Master F, Fill Magic e Clip F) after photopolymerization with LED-laser photoactivation system: : Radii-Cal (SDI, São Paulo, SP, BR). The flexural strength demonstrated by the provisional restorative materials Provi Master F (Wilcos), Systemp (Ivoclair) e Fill Magic (Coltene) was similar (p >0,05) and greater than that demonstrated by restorative materials BiFix (Voco) e Clip F (Voco) (p < 0,05). On the other hand, the flexural strength demonstrated by Be Fil and Clip F were similar among themselves (p > 0.05). We conclude that the materials Provi Master F, Systemp and Fill Magic are materials of better choice when we need a greater resistance to occlusal forces. / Mestre
|
87 |
Avaliação da resistência flexural de materiais restauradores provisórios resinosos / Evaluation of the flexural strength of temporary resin restorative materialsMachado, Carolina Ellen Spínola 17 May 2018 (has links)
Submitted by Carolina Ellen Spinola Machado (carolina.machado@unesp.br) on 2018-07-17T17:50:57Z
No. of bitstreams: 1
Tese Mestrado Carol Spinola Correção Final.pdf: 1288993 bytes, checksum: 2bda3149606dd9c289679698a83d6cbc (MD5) / Approved for entry into archive by Ana Cristina Jorge null (anacris@fclar.unesp.br) on 2018-07-17T18:28:03Z (GMT) No. of bitstreams: 1
machado_ces_me_arafo_int.pdf: 1335157 bytes, checksum: c25b86d1526dd6b3333d99b75d0e04b1 (MD5) / Made available in DSpace on 2018-07-17T18:28:03Z (GMT). No. of bitstreams: 1
machado_ces_me_arafo_int.pdf: 1335157 bytes, checksum: c25b86d1526dd6b3333d99b75d0e04b1 (MD5)
Previous issue date: 2018-05-17 / O objetivo do estudo foi avaliar a resistência flexural de materiais restauradores resinosos provisórios (Systemp Onlay, Bifix Temp, Provyl Master F, Fill Magic e Clip F) após a fotopolimerização com sistema de fotoativação LED-laser: Radii-Cal (SDI, São Paulo, SP, BR). A resistência flexural demonstrada pelos materiais restauradores provisórios Provi Master F (Wilcos), Systemp (Ivoclair) e Fill Magic (Coltene) foi similar (p >0,05) e maior que a demonstrada pelos materiais restauradores BiFix (Voco) e Clip F (Voco) (p < 0,05). Por outro lado, a resistência flexural apresentada pelo BiFix e Clip F foi semelhante entre si (p > 0.05). Concluimos assim que os materiais Provi Master F, Systemp e Fill Magic são materiais de melhor escolha quando necessitamos de uma resistência maior às forças oclusais. / The objective of this study was to evaluate the flexural strength of temporary resin restorative materials (Systemp Onlay, Bifix Temp, Provyl Master F, Fill Magic e Clip F) after photopolymerization with LED-laser photoactivation system: : Radii-Cal (SDI, São Paulo, SP, BR). The flexural strength demonstrated by the provisional restorative materials Provi Master F (Wilcos), Systemp (Ivoclair) e Fill Magic (Coltene) was similar (p >0,05) and greater than that demonstrated by restorative materials BiFix (Voco) e Clip F (Voco) (p < 0,05). On the other hand, the flexural strength demonstrated by Be Fil and Clip F were similar among themselves (p > 0.05). We conclude that the materials Provi Master F, Systemp and Fill Magic are materials of better choice when we need a greater resistance to occlusal forces.
|
88 |
Avaliação da distorção linear em estruturas métalicas de próteses sobre implantes: fundidas em peça única e em segmentos soldados a laser e através da soldagem convencional (brasagem)Costa, Elza Maria Valadares da [UNESP] 29 June 2001 (has links) (PDF)
Made available in DSpace on 2018-07-27T18:25:55Z (GMT). No. of bitstreams: 0
Previous issue date: 2001-06-29. Added 1 bitstream(s) on 2018-07-27T18:29:54Z : No. of bitstreams: 1
000138043.pdf: 3009336 bytes, checksum: 4461e732807121379a46347a761b1f11 (MD5) / Próteses sobre implantes osseointegrados requerem critério de fabricação preciso devido a ausência de tecidos periodontais que compensam erros menores de relacionamento. Para tanto, em um arco mandibular edêntulo, construído em aço-cromo, foram fixados cinco análogos de pilares de implante, paralelos entre si, com distância de 10mm medidos de centro a centro. Sobre estes foram parafusados novos cilindros de ouro, com torque de 10 N/cm. Então foram executadas 15 sobre-estruturas metálicas que foram divididas: GC - Adaptação passiva dos cilindros de ouro; GM - monobloco GB - segmentos soldados por brasagem e, GL - segmentos soldados a laser. Observou-se as estruturas parafusadas com parafusos sempre novos sob microscópio de mensuração. A medição foi realizada na vestibular e lingual da interface cilindro/análogo e dados anotados em tabela apropriada. Para o eixo y, a técnica de soldagem a laser (Media=12,41 e Dp=11,12) produziu menos distorção significativamente do que a técnica de brasagem (Media=23,06 e Dp=13,31) seguida pela técnica de monobloco (Media=39,83 e Dp=21,88) p= 0.05. Para o eixo x, somente o grupo Monobloco apresentou diferença significativa para as demais técnicas (Média= 45,66 e Dp=21,56) / Prosthesis above osseointegrated implants requires an accurate criterion of manufacture. So, in an edentulous mandibular arch, constructed with chromium steel, five analogous were fixed, parallels, with distance of 10 mm measured of center to center. Above these gold cylinders were positioned and screwed with a torque of 10 N/m. In the next follow, fifteen over structures were fabricated and divided in tour groups: CG - Passive adaptation of gold cylinders; MG - Monobloc casting; BG - Casting in segments after brasing; LG - Casting in segments after laser welding. The structures were observed with measures microscope and the data noted in specific table. The measures done in two points (left and right) in the buccal and lingual surfaces of the interface of the cylinder/analogous set in the x and y-axis. The statistics analysis (ANOVA) showed significant statistics differences, on y-axis, among groups: LG group was superior to BG and this was superior to MG group and on x-axis only MG was superior to others groups (when we studied distortion.)
|
89 |
Análise comparativa das tensões e deformações entre próteses implantossuportadas de três elementos com dois ou três pilares /Nishioka, Gabriela Nogueira de Melo. January 2016 (has links)
Orientador: Guilherme de Siqueira Ferreira Anzalone Saavedra / Banca: Alberto Noriyuki Kojima / Banca: José Scarso Filho / Resumo: O objetivo deste estudo foi avaliar as tensões e deformações in vitro, por meio da fotoelasticidade e da extensometria, em próteses parciais fixas implantossuportadas de três elementos variando o número de pilares: dois e três. O primeiro bloco de poliuretano (modelo mestre 1) recebeu três implantes e o segundo (modelo mestre 2) recebeu dois implantes, todos de hexágono externo. Em seguida, os modelos mestre foram duplicados em resina fotoelástica. Pilares protéticos microunit foram conectados aos implantes com torque de 20 Ncm. Sobre os pilares protéticos dos modelos mestre foram parafusados cilindros plásticos, que receberam estruturas em padrões de resinas, os quais foram fundidos em liga de Ni-Cr (n=10). Quatro extensômetros foram colados na superfície de cada bloco de poliuretano, tangenciando os implantes. Nos modelos mestre e nos modelos fotoelásticos, cada estrutura metálica foi parafusada sobre os pilares protéticos com torque de 10 Ncm. Os dados obtidos na extensometria foram submetidos aos testes estatísticos RM ANOVA e Tukey (5%). As franjas isocromáticas obtidas nos modelos fotoelásticos após cada condição de carga foram registradas com uma câmera digital, visualizadas em um programa de computador e comparadas qualitativamente. Resultados: Houve uma diferença estatística significante entre a quantidade de suporte de uma prótese fixa (p=0,001). Os resultados revelaram que três implantes apresentaram uma melhor distribuição das cargas em qualquer ponto analisado e ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The present study used photoelastic and strain gauge analysis to compare stress and microstrain to perform an in vitro evaluation of the effect of the numbers of support in a implant-supported fixed partial prostheses with tree elements. The first polyurethane block (master model 1) will contain three implants and the second block (model 2) two of them, all implants have a external hexagon. Then, the master models were duplicated in photoelastic resin. Microunit abutments were connected to the implants and received a 20 Ncm torque. Over the master model plastic prosthetic cylinders were screwed the abutments that received standard patterns cast in Ni-Cr alloy (n=10). Four strain gauges (SG) were bonded in the surface of the block, tangentially to the lateral implants. On the master model and photoelastic model, each metallic structure were screwed onto the abutments with a 10 Ncm torque. The data obtained from the strain gauge were analyzed statistically by RM ANOVA and Tukey's test, with a 5% conventional level of significance. The isochromatic fringes obtained in the photoelastic models after each load condition were recorded with a digital camera, visualized with software to facilitate qualitative analysis. Results: There was statistically significant differences in support of FPD( p=0,001).The results demonstrated that 3 implants has higher stress distribution and in the pontic of FPD we found higher stress (2326,95µε in 2 implants and 1006,57µε in 3 implants).In photoelastic images, 3 implants presented better stress distribution than 2 implants. Conclusions: Both methods found similar results. This study suggests ....(Resumo completo, clicar acesso eletrônico abaixo) / Mestre
|
90 |
Comportamento biomecânico de implantes retos e angulados sobre cargas axiais e não axiais por análise de elementos finitos e extensometria linear /Tribst, João Paulo Mendes. January 2017 (has links)
Orientador: Renato Sussumu Nishioka / Banca: Alexandre Luiz Souto Borges / Banca: Francisley Ávila Souza / Resumo: Este trabalho buscou estudar as microdeformações geradas ao redor de implantes de hexágono externo durante carregamentos axiais e não axiais, variando-se a angulação dos implantes, utilizando a análise por elementos finitos e a extensometria linear como ferramentas. Inicialmente modelos 3D de diferentes próteses fixas foram construídos a fim de se permitir uma correlação dos resultados encontrados no modelo simplificado com o modelo anatômico e assim validar a geometria da prótese utilizada no estudo. Após a confirmação dos resultados de tensão similar entre as próteses na região dos implantes e do bloco, o modelo da prótese simplificada foi definida como válida. Em seguida, um modelo de bloco de poliuretano foi criado e duplicado. Implantes com conexão de hexágono externo (HE) foram modelados e em um bloco representados perpendiculares à superfície enquanto que em outro bloco foram colocados com inclinação de 17°. Foram modelados também intermediários do tipo mini pilar cônico retos e angulados conforme a inclinação dos implantes. Por último, foi utilizado o modelo de supraestrutura previamente validada para ambos os grupos, na qual a carga foi incidida. Todos os constituintes foram considerados perfeitamente simétricos, sólidos, isotrópicos. Os modelos receberam cargas de 300 N/cm em pontos axiais e não axiais através do software de análise por elementos finitos para se verificar a tensão máxima principal e as microdeformações. Em seguida, através da análise experimental de... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract:This Work aimed to study the microstrains generated around external hexagon implants during axial and non-axial loads, varying the angulation of the implants, using finite element analysis and linear strain gauge as tools. Initially 3D models of different fixed prostheses were constructed in order to allow a correlation of the results found in the simplified model with the anatomical model and thus validate the geometry of the prosthesis used in the study. After confirming the results of similar stress between the prostheses in the implants and the block region, the simplified prosthesis was defined as valid. After, a polyurethane block model was created and duplicated. Implants with external hexagon connection (HE) were modeled and inserted perpendiculary into one block while in another block, were placed with the inclination of 17 °. Straight and angled mini conical abutments were also modeled according to the inclination of the implants. Finally, the supra-structure previously validated for both groups was used, through which the load was affected. All constituents were considered perfectly symmetrical, solid, and isotropic. The models received a load of 300 N / cm in axial and non-axial points through the finite element analysis software, to verify the maximum principal stress and microstrains. Then, through the experimental analysis of strain-gauge, two polyurethane blocks were prepared and received three HE implants each, as well as respective mini tapered pillars according to the inclination of the installed implants. Then, a metallic superstructure, identical to the computational model, was cast in Ni-Cr and screwed onto the implants with torque of 10 N / cm. The load of 300 N / cm was applied for 10 seconds at axial and non-axial points. To measure the microstrains, four extensometers were glued on the surface of....(Resumo completo, clicar a acesso eletrônico abaixo) / Mestre
|
Page generated in 0.0789 seconds