• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 49
  • 39
  • 16
  • 7
  • 7
  • 7
  • 7
  • 6
  • 4
  • 3
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 113
  • 113
  • 62
  • 47
  • 40
  • 39
  • 35
  • 28
  • 25
  • 17
  • 14
  • 13
  • 10
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Influência de tratamentos superficiais e termociclagem na resistência da união resina/metal

Almilhatti, Hercules Jorge [UNESP] 27 April 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-04-27Bitstream added on 2014-06-13T19:44:48Z : No. of bitstreams: 1 almilhatti_hj_dr_arafo.pdf: 2065564 bytes, checksum: 9ca5fe747a7a70b66a300c7564a4ad19 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo teve como objetivo avaliar a efetividade de quatro condicionadores de metal (Metal Photo Primer, MPP; Cesead II Opaque Primer, OP; Targis Link, TL e Siloc, S) aplicados sobre diferentes superfícies das ligas de Ni-Cr, Co-Cr e do metal Ti Cp. Após o polimento metalográfico e jateamento com Al2O3, foram obtidos três grupos experimentais para cada metal : Grupo polimento (P) - controle; Grupo (J50), jateado com Al2O3 de 250 um. A esses grupos foram aplicados os condicionadores e as resinas opaca e de revestimento estético (Artglass). Decorridos 24 horas de armazenamento em água a 37ºC, cada grupo foi dividido em dois grupos e submetidos aos ensaios mecânicos de cisalhamento (0,5 mm/min.), um antes e outro após 500 ciclos térmicos (60ºC e 4ºC). As superfícies fraturadas foram analisadas e o padrão de falhas determinado. Adicionalmente foram feitas análises de MEV e EDS. Seguem os resultados para cada metal: Liga de Ni-Cr: para os Grupos P e J50, não foram observadas diferenças (p>0,05) nos valores médios de tensão de cisalhamento entre os condicionadores OP e TL e entre MPP e S, sendo maiores as médias dos dois primeiros. Não foram encontradas diferenças (p>0,05) entre as médias de tensão para os condicionadores do Grupo J250. No entanto, esses valores foram superiores aos do Grupo J50. Após a termociclagem, as médias para os condicionadores OP, S e TL não apresentaram aumento significante (p>0,05), enquanto a média para o MPP aumentou (p<0,05). Liga de Co-Cr, para o Grupo P, não foram observadas diferenças (p>0,05) nos valores médios de tensão entre os condicionadores OP e TL e entre MPP e S, sendo superiores as médias dos dois primeiros. As médias de tensão para o Grupo J250 foram estatisticamente maiores às do Grupo J50,... / The purpose of the study was to evaluated the effect of three adhesive primers (Metal Photo Primer, MPP; Cesead II Opaque Primer, OP; Targis Link, TL) and a bonding system (Siloc, S) on the shear bond strength between a prosthetic composite material (Artglass) to Ni-Cr alloy (Wiron 99), Co-Cr alloy (Wironit), and CP Ti (Tritan). Disk patterns were cast of the 3 alloys. All the disk surfaces were abraded with No. 80, 320, and 600 SiC paper, respectively and three different surface treatment were applied: No. 600 SiC polishing, P; 50 mm Al2O3 sandblasting, S50; 250 mm Al2O3 sandblasting, S250. The composites (Artglass opaque and dentin) were applied using a cylindrical stainless steel split according to manufacturer's instructions then light polymerized. Specimens without primer and bonding system were also prepared as control. The specimens were stored in water a 37oC for 24 h and then shear bond strengths were determined both before and after immersed alternately in water baths at 4oC and 60oC for 15 seconds each for up to 500 thermal cycles before shear mode testing at a crosshead speed of 0.5 mm/min. Data were statistically analyzed using 3-way ANOVA and 1-way ANOVA, followed by Tukey multiple range intervals calculated at the 0.05 significance level. Fractured interfaces were analyzed by use of light microscopy and SEM. Results: Ni-Cr alloy: The bond strength of the P-OP/J50-OP group and P-TL/J50- TL group were statistically comparable (p>0,05) and exhibited greater strength than the P-MPP/J50-MPP group and P-S/J50-S (p<0,05). No significant differences were found among the four conditioners for J250 group (p>0,05), and these group showed the greater strength than the J50 group (p<0,05). After thermocycling, no significant differences (p>0,05) were found among the three primers (OP, S, TL) and the bond strength of MPP increased...(Complete abstract, click electronic access below)
102

Mechanical Properties Of Provisional Restorative Materials

Shimizu Oliva, Graciela, 1976- January 2010 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / A provisional restoration must fulfill biologic, mechanical, and esthetic requirements. These prostheses should provide comfort, pulp protection, positional stability, occlusal function, hygiene access, esthetics, strength and retention. Methyl-methacrylate acrylic has assumed many appli¬cations in the field of restorative dentistry. However, the material still has deficiencies, such as polymerization shrinkage, pulpal damage associated with exothermic polymerization and susceptibility to fracture. Bis-GMA composites, Bis-acryl composites and visible light-cured urethane dimethacrylate resins have been developed to address these issues. The purpose of this study was to compare the mechanical properties of provisional restorations made from composite resins (Protemp Plus, Luxatemp Solar, Radica, Protemp Crown) to those made of the traditional methacrylate resins (Jet, Snap, High Impact). Six groups of samples, two groups from methacrylate and four groups from composite based materials, were fabricated. Samples from each group were evaluated for microhardness (n=10), flexural strength and flexural modulus (n=20) according to ISO 4049, and fracture toughness (n=20) according to ISO 13586. From each of the six groups, ten samples were tested for flexural strength, flexural modulus and fracture toughness and 5 samples were tested for microhardness. These tests were done after storing at 37°C in a distilled water solution for 7 days followed by thermal cycling (2500 cycles, 5-55°C, 45 s. dwell). Identical sets of samples from each group were used as controls; these were tested after storing for 24 hours in dry conditions. The results were analyzed by two-way ANOVA with material type and aging conditions as the two main variables. Significance level was set at p=0.05. For flexural strength and flexural modules, the higher values were obtained for Radica. Protemp plus (7 days) and Radica (24h) had the highest fracture toughness value. Protemp crown showed the highest surface hardness. The mechanical properties of composite resin were superior.
103

Ispitivanje biokompatibilnosti i mehaničkih karakteristika polimera za bazu zubne proteze / The investigation of biocompatibility and mechanical properties of denture base resins

Potran Michal 05 November 2015 (has links)
<p>U uvodnom delu doktorske disertacije opisuje se kompleksnost problematike kori&scaron;ćenja polimera za bazu zubne proteze, sa osvrtom na njihove op&scaron;te osobine, stepen biokompatibilnosti i njihove mehaničke karakteristike. Detaljno je opisana problematika ispitivanja stomatolo&scaron;kih materijala i napravljeno je poređenje i korelacija između in vitro i in vivo načina ispitivanja biokompatibilnosti. Drugi deo obuhvata ispitivanje čvrstoće polimera za bazu zubne proteze i analizu uticaja osobina materijala u odnosu na biolo&scaron;ku sredinu u kojoj obavljaju svoju funkciju, i u odnosu na sile kojima su tokom funkcije materijali izloženi. Cilj doktorske disertacije je utvrđivanje stepena biokompatibilnosti i mehaničkih karakteristika toplopolimerizujućih, hladnopolimerizujućih i termoplastičnih akrilata za bazu zubne proteze. Istraživanje je obuhvatilo 3 komercijalna materijala iz grupe akrilata, koji se razlikuju po hemijskom sastavu i načinu polimerizacije. Ispitivanje biokompatibilnosti rađeno je u in vitro i in vivo uslovima. Ispitivanje na ćelijskim kulturama obuhvatalo je dve ćelisjke linije (MRC 5 i L929) sa dva načina kontakta između ćelija i materijala (direktan, indirektan) i dva načina određivanja biolo&scaron;kog ishoda (MTT test, Agar difuzioni test). Istraživanje urađeno in vivo obuhvatalo je test subkutane implantacije, na animalnom modelu pacova, i test iritacije oralne sluzokože na animalnom modelu hrčka. Oba testa rađena su u skladu sa standardom ISO 10993. Cilj in vivo istraživanja bio je ispitivanje reakcije tkiva na implantirani materijal, računajući i zavr&scaron;nu integraciju ili dezintegraciju implantiranog materijala. Prednost in vivo istraživanja nalazi seu analizi uticaja materijala na sterilno živo tkivo, uz praćenje imunolo&scaron;ke reakcije, kao dopuna prethodnom istraživanju na ćelijskim kulturama. Dopunski deo in vivo ispitivanja biokompatibilnosti određen je prema kliničkoj upotrebi ispitivanih materijala, zbog čega je odabran test oralne iritacije sluzokože. Sluzokoža bukalne kesice sirijskog hrčka sastoji se od pločasto slojvitog epitela sa orožavanjem, &scaron;to je predstavljao dobar model za ispitivanje polimera za bazu zubne proteze, po&scaron;to zubna proteza naleže na sluzokožu nepca i rezidualnog alveolarnog grebena koja takođe orožava. Drugi deo disertacije obuhvatao je ispitivanje mehaničkih karakteristika, pri čemu su urađeni test zatezne čvrstoće, test savojne čvrstoće, test čvrstoće loma i mikrotvrdoće, uz dopunsku analizu pratećih parametara. Rezultati ispitivanja biokompatibilnosti pokazali su da su testovi biokompatibilnosti osetljivi na upražnjeni metodolo&scaron;ki postupak. Ispitivanjem na ćelijskim kulturama nisu utvrđene značajne razlike u citotoksičnosti između toplopolimerizujućih, hladnopolimerizujućih i termoplastičnih akrilata. Takođe, rezultati su se razlikovali u odnosu na tip ćelijske kulture i način provere biolo&scaron;kog ishoda, &scaron;to se slaže sa prethodnim navodima o kompleksnoj problematici njihovog međusobnog poređenja. Ispitivanjem biokompatibilnosti subkutanom implantacijom praćen je inflamatorni odgovor tkiva u vremenskom intervalu od 90 dana. Reakcija organizma na implantirani materijal posmatrana je kroz ćelijske i tkivne parametre, u skladu sa ISO 10993. Dodatno je urađena i analiza hrapavosti implantiranih materijala. Histolo&scaron;kom analizom utvrđena je razlika u inflamatornom odgovoru u odnosu na kori&scaron;ćeni materijal, kao i prema vremenskom intervalu implantacije. Test oralne iritacije sluzokože nije se pokazao kao dovoljno senzitivan za ispitivanje ovih vrsta materijala. Ispitivanjem mehaničkih karakteristika utvrđene su razlike između toplopolimerizujućih, hladnopolimerizujućih i termoplastičnih akrilata. Najveći stepen čvrstoće utvrđen je kod toplopolimerizujućih akrilata dok je najveća konzistentnost rezultata bila u grupi termoplastičnih akrilata. Prezentovano istraživanje predstavlja prvu detaljnu analizu biokompatibilnosti i mehaničkih karaktestistika polimera za bazu zubne proteze.</p> / <p>The introduction describes the complexity of use of denture base materials, with regard to their general characteristics, biocompatibility and mechanical properties. Issues related to the testing of dental materials is described in detail and comparison is made between in vitro and in vivo methods of biocompatibility testing. The second part further covers the determination of strength of previously used materials, in relation to biological environment in which their function is conducted and in relation to the influence of masticatory forces which can contribute to their mechanical failure. The aim of the presented research was to assess the degree of biocompatibility and mechanical properties of cold curing, hot curing and thermoformed denture base materials. The research included three denture base materials, which differed according to their chemical composition and polymerization protocols. The biocompatibility testing was carried out in in vitro and in vivo conditions. The in vitro experiments covered two different cell lines (MRC 5 human lung fibroblasts and L929 mouse fibroblasts) with two types of contact (direct, indirect) and two different types of quantification of biological outcome (MTT assay and Agar overley test). The in vivo assessment of biocompatibility covered the subcutaneous implantation test, on the animal model of Wistar rat, and oral mucosa irritation test, on the animal model of sirian hamster. Both tests were conducted according to the ISO 10993. The aim of the in vivo investigation was to evaluate tissue reactions to the implanted materials, including the final integration or disintegration of the tested materials. The advantage of in vivo investigation included the possibility of monitoring the materials influence on living tissues, with the analysis of imunological response as an addition to the previously conductedresearchon cell cultures. The supplemental part of in vivo investigation was chosen according to the clinical use of the tested materials, which included the oral mucosa irritation test.The mucosa of hamster buccal pouch consists of stratified squamos epithelium, which is considered to be an adequate replacement for the human denture supporting tissues, which also consist of the same type of epithelium. The second part of thesis includes the determination of mechanical properties of denture base materials. It consists of four types of tests: tensile strength test, bending strength test, fracture toughness test and microhardness tests, followed by the analysis of corresponding parameters. The results of the biocompatibility tests showed that the biological outcome of the applied method is highly depended on the methodological procedure. The investigation conducted in vitro, on two different cell lines, did not show significant difference in cytotoxicity between hot curing, cold curing and thermoformed denture base materials. Also, the results were influenced by the type of cell culture and the evaluation method of biological outcome, which agrees with the previous allegations about the complexicity of their mutual comparison. The subcutaneous implantation test covered the inflammatory response in the time period of 90 days. The organism reaction to the implanted material was determined through the cell and tissue parameters of organism response, evaluation of which was conducted according to the ISO 10993. Additionally, the surface roughness of the implanted specimens of materials was also measured. The inflammatory response of the ogranism was influenced by the type of the implanted material and the time interval of implantation. The oral mucosa irritation test has proven not to be sufficiently sensitive for testing of this type of materials. Testing of the mechanical properties od denture base materials, revealed the difference between the cold curing, hot curing and thermofomed denture base materials. The highest strength was observed in hot curing materials, while the highest consistency of the results was observed in thermoformed resins. The presented investigation presents the first detail analysis of the biocompatibility and mechanical properties of the denture base materials, and as such presents a novelty in the field of dental materials characterization.</p>
104

Estudo comparativo entre um novo método de transferência de planos guias no preparo de boca para Próteses Parciais Removíveis e outras duas técnicas / Comparative study between a new method for tranferring guide planes on mouth preparation for Removable Partial Denture and two other techniques

Yamaguchi, Cláudio Akira 18 August 2011 (has links)
A confecção de uma prótese parcial removível exige a correta determinação do eixo de inserção e, consequentemente, o preparo cuidadoso de planos guias para satisfazer os princípios de retenção e estabilidade. Entretanto, grande parte dos profissionais negligencia esta etapa, seja por desconhecimento de sua importância, dificuldade técnica, quantidade limitada de opções cientificamente comprovadas de seus resultados, ou pela aparente e ilusória economia de tempo e de trabalho que sua realização possa tomar. Então, em função do número limitado de técnicas eficientes para transferência de planos guias e da necessidade de um método que otimize o tempo dos profissionais de forma prática e didática, o presente estudo buscou introduzir uma nova maneira de transferir os planos guias. A nova técnica consiste na utilização de uma placa de vacuum-form (PV), comparando-a com preparos realizados em delineador e com duas outras técnicas pré-existentes: à mão livre (ML) e coroas-guia (CG), analisando sua eficácia e precisão. Réplicas idênticas (n=44) de um modelo de gesso representativo da arcada inferior foram divididas em 11 grupos, com 4 modelos cada. Cada um dos onze estudantes de Odontologia recebeu 4 modelos - em um deles os planos guias já tinham sido previamente preparados com delineador, os quais serviram apenas de referência para que fossem empregados os outros métodos. As diferenças angulares dos planos guias nos 44 modelos, nos sentidos ântero-posterior, látero-lateral e cruzado foram mensuradas por meio de uma máquina de medição por coordenadas. A análise de variância para medidas repetidas e o Teste de Comparações Múltiplas (método de Tukey) revelaram que tanto no sentido látero-lateral, como na avaliação cruzada, houve diferença significativa na média dos preparos feitos no delineador em relação a todas as outras técnicas. No entanto, não foram identificadas diferenças importantes entre os três métodos. Para a avaliação ântero-posterior, verificou-se diferença relevante somente entre os preparos feitos no delineador e CG, o que não foi detectado entre ML, PV e delineador. Observou-se também, que os preparos obtidos com delineador apresentaram variações angulares próximos de zero, indicando paralelismo quase absoluto e que os planos guias preparados nesse dispositivo demonstraram média e variabilidade menores que os outros métodos. As demais técnicas (ML, CG e PV) se comportaram de forma estatistica semelhante, exceto no sentido ântero-posterior, onde a CG apresentou maior variação angular. Concluiu-se que a técnica proposta apresentou resultados satisfatórios em relação aos padrões adotados neste estudo, quando comparada às demais técnicas e ao delineador. Portanto, a mesma pode ser considerada viável, já que sua utilização oferece uma confecção de próteses removíveis de forma mais criteriosa, atendendo às necessidades profissionais, em termos de facilidade e tempo gasto em sua execução. / The confection of a removable partial denture requires accurate determination of the path of insertion and consequently, the careful preparation of guide planes to meet the principles of retention and stability. However, a great number of professionals neglect this step because of unconsciousness of its importance, or technical difficulty, or limited options of techniques or because of apparent and illusory saving of time and work. Due to the limited number of proven effective techniques for guide planes preparation and the need of an effective method for optimizing time of dental surgeons in a clear and practical way, this present study aimed the introduction of a new technique for transferring guide planes. The new technique consists on the use of a vacuum form splint (VF). To measure its efficiency and accuracy it was compared with the preparations carried out in a dental surveyor and with two other pre-existing techniques: freehand (FH) and acrylic resin guide crown (GC). Identical replicas (n=44) of a gypsum model representing a dental lower arch were divided into 11 groups of four. Each of the eleven dental students received four models - in one of the models, the guide planes were previously prepared with the surveyor to be used as a reference for the application of the three transfer techniques in the other three remaining models. The angular differences of the the prepared guide planes on the 44 models were measured by a coordinate measuring machine in the anteroposterior, laterolateral and crossed views. The Analysis of Variance and Tukey method revealed that, for the laterolateral evaluation and crossed evaluation, significant differences were found in the average of the preparations obtained by the surveyor in relation to all other techniques. There were no significant differences among the three techniques. Anteroposterior evaluation showed significant difference between the average of the preparations made by the surveyor and by the GC, which was not observed between the FH and PV groups compared to the surveyor. It was also found that the angular variation obtained by preparations using the surveyor was close to zero degree, indicating almost absolute parallelism. The FH, GC and VF techniques were statistically similar, except for the anteroposterior evaluation. In the anteroposterior evaluation the GC presented higher angular variation. It was concluded that the proposed technique showed satisfactory results concerning the adopted standards in the present study when compared with the preparations made by other techniques and the surveyor. Thus, the VF technique can be considered viable, since it improves the quality of the Removable Partial Denture and meets the professional needs, saving time in the procedures.
105

Avaliação da influência do diâmetro e comprimento do implante osseointegrado associado à PPR Classe I mandibular pelo método dos elementos finitos /

Verri, Fellippo Ramos. January 2003 (has links)
Orientador: Eduardo Piza Pellizzer / Banca: Dalva Cruz Laganá / Banca: Eduardo Passos Rocha / Resumo: A influência do diâmetro e do comprimento de implantes osseointegrados em associação com próteses parciais removíveis de extremidade livre (PPRELs) ainda não foi relatada na literatura. Dessa forma, este trabalho visou avaliar a esta influência, utilizando o método dos elementos finitos (MEF) bi-dimensional, associando implantes osseointegrados do sistema Branemark sob a base protética de uma PPREL, funcionando apenas como suporte, e analisando mapas de deslocamento e de tensão de von Mises. Para o estudo foram confeccionados oito modelos representativos de uma hemi-arcada mandibular com a presença apenas dos dentes 33 e 34, com as seguintes características: A - sem PPR; B - com PPR sem implante; C - com PPR e implante de 3,75 x 7,00 mm; D - com PPR e implante de 3,75 x 10,00 mm; E - com PPR e implante de 3,75 x 13,00 mm; F - com PPR e implante de 5,00 x 7,00 mm; G - com PPR e implante de 5,00 x 10,00 mm; H - com PPR e implante de 5,00 x 13,00 mm. As forças aplicadas foram estritamente verticais e de 50 N em cada ponta de cúspide. Pelos resultados notou-se que a presença da PPR sobrecarregou o dente suporte, bem como as demais estruturas de suporte da PPR quando comparadas com o modelo A. A presença do implante diminuiu as tensões, principalmente nas extremidades do rebordo desdentado, quando comparados o modelo B com os modelos que possuíam implantes associados. Tanto o comprimento quanto o diâmetro do implante tenderam a diminuir as tensões à medida que aumentavam suas dimensões. Pelos resultados foi possível concluir que: o modelo B foi o que apresentou a maior tendência a deslocamento; quanto maior o comprimento do implante, menores foram os valores do mapa de deslocamento; o modelo B apresentou níveis de tensão de von Mises superiores ao modelo A; os modelos com implantes associados apresentaram níveis menores de tensão de von Mises que o modelo B nas estruturas de suporte da PPR. / Abstract: The influence of the diameter and length of osseointegrated implants in association with removable partial prostheses of distal-extension (DERPDs) it was not still reported in the literature. In that way, this study evaluated this influence, associating osseointegrated implants of the Branemark system under the prosthetic base of a DERPD, just working as support, and analyzing displacement and von Mises tension maps, using bi-dimensional finite element analysis (FEA). For this study, eight representative models of a lower hemi-arcade were made with the presence of only the teeth 33 and 34, with the following characteristics: A - without RPD; B - with RPD and without implants; C - with RPD and implant of 3,75 x 7,00 mm; D - with RPD and implant of 3,75 x 10,00 mm; E - with RPD and implant of 3,75 x 13,00 mm; F - with RPD and implant of 5,00 x 7,00 mm; G - with RPD and implant of 5,00 x 10,00 mm; H - with RPD and implant of 5,00 x 13,00 mm. The applied forces were strictly vertical and of 50 N in each edge tip. The results shown that the presence of RPD overloaded the support tooth, as well as the other structures of support of RPD when compared with the model A. The presence of the implants reduced the tensions, mainly in the extremities of the toothless edge, when compared model B with the models that possessed implant associated. So much the length as the diameter of the implants tended to reduce the tensions as increased your dimensions. For the results it was possible to conclude that: the model B was what presented the largest tendency to displacement; as larger the length of the it implants, smaller they were the values of the displacement map; the model B presented levels of von Mises tension superiors to the model A; the models with implant associated presented smaller levels of von Mises tension that the model B in the structures of support of RPD; the increase of the length and of the diameter of the implants. / Mestre
106

Avaliação da influência do diâmetro e comprimento do implante osseointegrado associado à PPR Classe I mandibular pelo método dos elementos finitos

Verri, Fellippo Ramos [UNESP] January 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2003Bitstream added on 2014-06-13T20:37:57Z : No. of bitstreams: 1 verri_fr_me_araca.pdf: 6651997 bytes, checksum: 6bb3237d2e73d295c300ea6f6f9c9014 (MD5) / A influência do diâmetro e do comprimento de implantes osseointegrados em associação com próteses parciais removíveis de extremidade livre (PPRELs) ainda não foi relatada na literatura. Dessa forma, este trabalho visou avaliar a esta influência, utilizando o método dos elementos finitos (MEF) bi-dimensional, associando implantes osseointegrados do sistema Branemark sob a base protética de uma PPREL, funcionando apenas como suporte, e analisando mapas de deslocamento e de tensão de von Mises. Para o estudo foram confeccionados oito modelos representativos de uma hemi-arcada mandibular com a presença apenas dos dentes 33 e 34, com as seguintes características: A - sem PPR; B - com PPR sem implante; C - com PPR e implante de 3,75 x 7,00 mm; D - com PPR e implante de 3,75 x 10,00 mm; E - com PPR e implante de 3,75 x 13,00 mm; F - com PPR e implante de 5,00 x 7,00 mm; G - com PPR e implante de 5,00 x 10,00 mm; H - com PPR e implante de 5,00 x 13,00 mm. As forças aplicadas foram estritamente verticais e de 50 N em cada ponta de cúspide. Pelos resultados notou-se que a presença da PPR sobrecarregou o dente suporte, bem como as demais estruturas de suporte da PPR quando comparadas com o modelo A. A presença do implante diminuiu as tensões, principalmente nas extremidades do rebordo desdentado, quando comparados o modelo B com os modelos que possuíam implantes associados. Tanto o comprimento quanto o diâmetro do implante tenderam a diminuir as tensões à medida que aumentavam suas dimensões. Pelos resultados foi possível concluir que: o modelo B foi o que apresentou a maior tendência a deslocamento; quanto maior o comprimento do implante, menores foram os valores do mapa de deslocamento; o modelo B apresentou níveis de tensão de von Mises superiores ao modelo A; os modelos com implantes associados apresentaram níveis menores de tensão de von Mises que o modelo B nas estruturas de suporte da PPR. / The influence of the diameter and length of osseointegrated implants in association with removable partial prostheses of distal-extension (DERPDs) it was not still reported in the literature. In that way, this study evaluated this influence, associating osseointegrated implants of the Branemark system under the prosthetic base of a DERPD, just working as support, and analyzing displacement and von Mises tension maps, using bi-dimensional finite element analysis (FEA). For this study, eight representative models of a lower hemi-arcade were made with the presence of only the teeth 33 and 34, with the following characteristics: A - without RPD; B - with RPD and without implants; C - with RPD and implant of 3,75 x 7,00 mm; D - with RPD and implant of 3,75 x 10,00 mm; E - with RPD and implant of 3,75 x 13,00 mm; F - with RPD and implant of 5,00 x 7,00 mm; G - with RPD and implant of 5,00 x 10,00 mm; H - with RPD and implant of 5,00 x 13,00 mm. The applied forces were strictly vertical and of 50 N in each edge tip. The results shown that the presence of RPD overloaded the support tooth, as well as the other structures of support of RPD when compared with the model A. The presence of the implants reduced the tensions, mainly in the extremities of the toothless edge, when compared model B with the models that possessed implant associated. So much the length as the diameter of the implants tended to reduce the tensions as increased your dimensions. For the results it was possible to conclude that: the model B was what presented the largest tendency to displacement; as larger the length of the it implants, smaller they were the values of the displacement map; the model B presented levels of von Mises tension superiors to the model A; the models with implant associated presented smaller levels of von Mises tension that the model B in the structures of support of RPD; the increase of the length and of the diameter of the implants.
107

Influência dos sistemas de retenção e da inclinação do rebordo residual em casos de próteses conjugadas Classe I mandibular: análise da distribuição das tensões pelo método da fotoelasticidade

Ferraço, Renato [UNESP] 24 April 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-04-24Bitstream added on 2014-06-13T19:37:37Z : No. of bitstreams: 1 ferraco_r_me_araca.pdf: 1898873 bytes, checksum: a4b549caf699d7868a711624716d6212 (MD5) / A reabilitação de pacientes classe I de Kennedy mandibular através de Prótese Parcial Removível é de difícil resolução devido a diferença de resiliência existente entre o ligamento periodontal dos dentes suportes e a mucosa do rebordo residual. A inclinação do rebordo residual no sentido sagital pode influenciar na distribuição das tensões transmitidas pela incidência de cargas em próteses parciais removíveis de extremidade livre associadas a próteses parciais fixas. Na associação da prótese parcial removível com próteses parciais fixas, o profissional tem como alternativa aos grampos tradicionais, o uso de encaixes extra-coronários que podem melhorar a estética e o funcionamento biomecânico do conjunto. Desse modo, o objetivo desse estudo foi avaliar a característica da distribuição de tensões em próteses parciais removíveis mandibulares de extremidade livre associadas a próteses parciais fixas nos dentes suporte com diferentes sistemas de retenção: (1) grampo por ação de pontas; (2) sistema ASC-52; (3) sistema ERA; e (4) encaixe de semi-precisão Score-PD, pela metodologia da fotoelasticidade. E, analisar a distribuição de tensões em próteses parciais removíveis mandibulares de extremidade livre associadas a próteses parciais fixas nos dentes suporte com diferentes sistemas de retenção: (1) grampo por ação de pontas e (2) sistema ERA, variando duas inclinações de rebordo residual: (1) horizontal e (2) descendente distal. Cargas axiais de 100N foram aplicadas sobre os dentes das próteses parciais removíveis. As imagens das aplicações foram capturadas e a distribuição das tensões foi avaliada, pela formação das franjas fotoelásticas. No primeiro estudo, a prótese com encaixes de semi-precisão produziu os maiores níveis de tensão na região de ápice, entre as raízes dos últimos dentes suporte e na porção mais distal do rebordo... / The rehabilitation of patients mandibular class I of Kennedy through Removable Partial Denture is difficult to solve because the difference in strength between the periodontal ligament of the abutment teeth and the residual ridge mucosa. The inclination of the residual ridge towards sagital may influence the distribution of stresses transmitted by the incidence of loads in distal extension removable partial dentures associated with fixed partial dentures. In association removable partial denture – fixed partial dentures, the professional has as alternative to the traditional clasps, the use of extra-coronary attachments that can improve the aesthetics and the biomechanics. Therefore, the objective of this study was to evaluate the characteristic distribution of tensions in mandibular distal extension removable partial dentures (1) “I” bar clasps, (2) ASC-52system, (3) ERA system, and (4) semi-precision Score-PD system, by the methodology of photoelasticity. And, analyze the distribution of tensions in mandibular distal extension removable partial dentures associated to the fixed partial dentures in the abutment teeth with different retention systems: (1) “I” bar clasps and (2) ERA system, ranging from two inclinations residual ridge: (1) horizontal and (2) distal descending. Axial loads of 100N were applied on the teeth of removable partial dentures. The images of the applications were captured and distribution of stress was assessed by the formation of the photoelastic fringes. In the first study, the prosthesis with semi-precision attachment produced the highest levels of tension in the region of apex, between the roots of the abutment teeth and in the more distal portion of the residual ridge. The prostheses with resilient attachments showed the largest fringes formations in the cervical-distal of the last abutment tooth. In the second study, horizontal ridge presented... (Complete abstract click electronic access below)
108

Avaliação do nível de inserção óssea do dente suporte em prótese parcial removível mandibular classe I associada a implante osseointegrado: análise pelo método dos elementos finitos

Verri, Fellippo Ramos [UNESP] 11 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-12-11Bitstream added on 2014-06-13T19:44:51Z : No. of bitstreams: 1 verri_fr_dr_araca.pdf: 1853726 bytes, checksum: 578403c1602d78c980bb821e076ea43c (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A colocação de PPR de extremidade livre no arco inferior é uma das mais complexas dentro da área protética. A associação desta com implantes na região distal tem melhorado biomecanicamente seu funcionamento. Porém, existem poucos estudos a respeito desta associação levando em consideração o nível de inserção óssea do dente suporte. Assim, o objetivo desta pesquisa foi avaliar, por meio do método dos elementos finitos bidimensional, a distribuição de tensão nas estruturas de suporte de uma PPREL, associada a um implante osseointegrado de 10,0 x 3,75 mm (Sistema Branemark), próximo ao dente suporte, com diferentes níveis de inserção óssea (íntegro e 1/2 da raiz) e com diferentes tipos de conexão entre a PPR e o dente suporte (apoio incisal e placa distal). Para o estudo, foram confeccionados 8 modelos mandibulares, de extremo livre, com a presença apenas do dente 33, sendo: MA - PPREL convencional, apoio incisal distal, inserção íntegra; MB - idem ao MA, mas utilizando placa distal; MC - idem ao MA, com implante de 3,75 x 10,0 mm e sistema ERA associado; MD - idem ao MC, mas utilizando placa distal; ME - idem ao MA, mas com perda de inserção de 1/2 da raiz; MF - idem ao MB, mas com perda de inserção de 1/2 da raiz; MG - idem ao MC, mas com perda de inserção de 1/2 da raiz; MH - idem ao MD, mas com perda de inserção de 1/2 da raiz. Com o auxilio do programa ANSYS 9.0, os modelos foram carregados com forças verticais de 50 N em cada ponta de cúspide. Os resultados foram obtidos pelos mapas de deslocamento e de tensão de von Mises e mostraram que o implante favorece a associação da forma descrita, que a placa possibilita um maior alívio e menor deslocamento do dente suporte, e que a perda do periodonto de suporte prejudica o prognóstico da prótese. / The rehabilitation with distal extension RPDA is very complex in the prosthetic area and the association with implants had improving its work biomechanical. However, there is little studies about this type of association and no study about the lost of insertion was encountered by FEA. So, the aim of this study was to evaluate, by FEA 2-D, the tension distribution in support structures of a DERPD associated with a osseointegrated implant of 10,0 x 3,75 mm (Branemark System), near to support tooth, with different levels of bone insertion (no lost and 1/2 of root) and with different type of connection between the DERPD and de support tooth (incisal rest and distal plate). For the study, 8 distal extension mandibular models were made, with the presence of tooth 33, presenting: MA - conventional DERPD, incisal rest, no bone lost; MB - like MA, but with distal plate; MC - like MA, but with implanto of 3,75 x 10,0 mm and ERA system associated; MD - like MC, but with distal plate; ME - like MA, but with bone lost of 1/2 of root; MF - like MB, but with bone lost of 1/2 of root; MG - like MC, but with bone lost of 1/2 of root; MH - like MD, but with bone lost of 1/2 of root. By mean of program of FEA ANSYS 9.0, the models were carried with axial forces of 50 N in each cusp tip. The results were obtained by dislodgement maps and von Mises tension maps and shown that the implant was benefit to association by the study, and the plate decreased the tension and the dislodgement of the support tooth, and the bone lost was prejudicial to prognostic of this type of prosthesis. By this methodology, was possible to conclude that: the introduction of an osseointegrated implant with ERA system used like this study decrease the dislodgement of above structures in all models.
109

RESISTÊNCIA À FRATURA DE PILARES DE PRÓTESES FIXAS RESTAURADOS COM NÚCLEO DIRETO E INDIRETO EM MANDÍBULAS DE SUÍNOS / FRACTURE STRENGTH OF FIXED PARTIAL DENTURES ABUTMENTS RESTORED WITH DIRECT AND INDIRECT CORE IN SWINE JAW

Palma, Débora Chiele 09 March 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to compare the fracture strength of abutment teeth, under fixed partial denture (FPD), restored with direct and indirect core, to analyze the type of fracture and to verify its relation to the type of core used. A total of 15 bone blocks taken from the jaw of adult swine, with at least 1th and 3rd molars, that were the abutment teeth for the FPD. The specimens were divided into 3 experimental groups (GR): GR I - (control) dentine core, GR II - cast metallic core in non-precious Cu-Al alloy (NPG, Aalbadent, USA) and GR III - glass fiber post (White post DC, FGM, BRA) and composite resin (Opallis, FGM, BRA). The standardization of coronary core was performed by a matrix of acetate obtained from the preparation of the GR I. The cementation of intraradicular retainers was performed with dual self-adhesive resin cement (RelyX U100, 3MESPE, USA). Infrastructures for FPDs of four elements were waxed, from acetate matrix to standardize the size and shape, casted with non-precious Ni-Cr alloy (Wironia light, Wilcos, USA) and cemented with dual self-adhesive resin cement (RelyX U100, 3MESPE, USA). The bone blocks were embedded in acrylic resin and subjected to compression test by universal testing machine, until fracture. The fractures were classified as repairable (upper or to the bone level) or irreparable (beyond the bone level), after analysis by stereomicroscope and tomography computed. Tests Analysis of variance and Fisher's exact test (p<0.05) were applied for statistical analysis. For the variable fracture strength, there were no statistical differences among the cores tested (p = 0.113), both GR I and the GR III, 100% of the fractures were repairable and GR II, 80% of the fractures were irreparable. There is evidence of association between fracture type and the core type used (p = 0.011). It was possible to conclude that: 1. The type of core used did not influence the fracture strength of the abutment teeth. 2. The type of fracture occurred in the abutments was predominantly repairable, when restored with direct core, and irreparable when restored with indirect core. 3. There is association between core type and the fracture type occurred. / O objetivo deste estudo foi comparar a resistência à fratura de pilares de próteses parciais fixas (PPFS) restaurados com núcleo em dentina, com pino de fibra de vidro e resina composta e com núcleo metálico fundido; analisar o tipo de fratura (reparável ou irreparável) e verificar a sua relação com o tipo de núcleo utilizado. Foram utilizados 15 blocos ósseos extraídos da mandíbula de suínos adultos, com 1º, 2º e 3º molares, que constituíram os pilares para a PPF. Os espécimes foram divididos em 3 grupos (GR) experimentais: GR I - (controle) núcleo em dentina, GR II - núcleo metálico fundido (NMF) em liga não preciosa Cu-Al (NPG, Aalbadent, USA) e GR III - pino de fibra de vidro - PFV (White post DC, FGM, BRA) e resina composta - RC (Opallis, FGM, BRA). A padronização coronária dos núcleos foi realizada através de uma matriz de acetato obtida a partir do preparo do GR I. A cimentação dos retentores intrarradiculares foi realizada com cimento resinoso autoadesivo dual (Relyx U100, 3MESPE, USA). Infraestruturas para PPFs de 4 elementos foram enceradas, a partir de uma matriz de acetato para padronização de dimensão e formato, fundidas em liga não preciosa Ni-Cr (Wironia light, Wilcos, BRA) e cimentadas com cimento resinoso autoadesivo dual (Relyx U100, 3MESPE, USA). Posteriormente, os blocos ósseos foram embutidos em resina acrílica autopolimerizável e submetidos ao ensaio de compressão em máquina de ensaio universal até a fratura. As fraturas foram classificadas como reparáveis (acima ou ao nível da crista óssea) ou irreparáveis (abaixo da crista óssea), após análise por estereomicroscópio e tomografias computadorizadas. Foram aplicados os testes Análise de Variância e Teste Exato de Fisher (p<0,05) para análise estatística. Para a variável resistência à fratura, não foi observada diferença estatística entre os núcleos testados (p=0,113), tanto no GR I quanto no GR III, 100% das fraturas foram reparáveis e no GR II, 80% das fraturas foram irreparáveis. Foi verificada associação entre tipo de fratura e o tipo de núcleo utilizado (p=0,011). Concluiu-se que o tipo de núcleo utilizado não influencia a resistência à fratura dos dentes pilares, entretanto influencia o tipo de fratura gerado.
110

Influência de tratamentos superficiais e termociclagem na resistência da união resina/metal /

Almilhatti, Hercules Jorge. January 2004 (has links)
Orientador: Eunice Teresinha Giampaolo / Banca: Gelson Luis Adabo / Banca: Carlos Eduardo Vergani / Banca: Maria da Glória Chiarello de Mattos / Banca: Ricardo Faria Ribeiro / Resumo: Este estudo teve como objetivo avaliar a efetividade de quatro condicionadores de metal (Metal Photo Primer, MPP; Cesead II Opaque Primer, OP; Targis Link, TL e Siloc, S) aplicados sobre diferentes superfícies das ligas de Ni-Cr, Co-Cr e do metal Ti Cp. Após o polimento metalográfico e jateamento com Al2O3, foram obtidos três grupos experimentais para cada metal : Grupo polimento (P) - controle; Grupo (J50), jateado com Al2O3 de 250 um. A esses grupos foram aplicados os condicionadores e as resinas opaca e de revestimento estético (Artglass). Decorridos 24 horas de armazenamento em água a 37ºC, cada grupo foi dividido em dois grupos e submetidos aos ensaios mecânicos de cisalhamento (0,5 mm/min.), um antes e outro após 500 ciclos térmicos (60ºC e 4ºC). As superfícies fraturadas foram analisadas e o padrão de falhas determinado. Adicionalmente foram feitas análises de MEV e EDS. Seguem os resultados para cada metal: Liga de Ni-Cr: para os Grupos P e J50, não foram observadas diferenças (p>0,05) nos valores médios de tensão de cisalhamento entre os condicionadores OP e TL e entre MPP e S, sendo maiores as médias dos dois primeiros. Não foram encontradas diferenças (p>0,05) entre as médias de tensão para os condicionadores do Grupo J250. No entanto, esses valores foram superiores aos do Grupo J50. Após a termociclagem, as médias para os condicionadores OP, S e TL não apresentaram aumento significante (p>0,05), enquanto a média para o MPP aumentou (p<0,05). Liga de Co-Cr, para o Grupo P, não foram observadas diferenças (p>0,05) nos valores médios de tensão entre os condicionadores OP e TL e entre MPP e S, sendo superiores as médias dos dois primeiros. As médias de tensão para o Grupo J250 foram estatisticamente maiores às do Grupo J50, ...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of the study was to evaluated the effect of three adhesive primers (Metal Photo Primer, MPP; Cesead II Opaque Primer, OP; Targis Link, TL) and a bonding system (Siloc, S) on the shear bond strength between a prosthetic composite material (Artglass) to Ni-Cr alloy (Wiron 99), Co-Cr alloy (Wironit), and CP Ti (Tritan). Disk patterns were cast of the 3 alloys. All the disk surfaces were abraded with No. 80, 320, and 600 SiC paper, respectively and three different surface treatment were applied: No. 600 SiC polishing, P; 50 mm Al2O3 sandblasting, S50; 250 mm Al2O3 sandblasting, S250. The composites (Artglass opaque and dentin) were applied using a cylindrical stainless steel split according to manufacturer's instructions then light polymerized. Specimens without primer and bonding system were also prepared as control. The specimens were stored in water a 37oC for 24 h and then shear bond strengths were determined both before and after immersed alternately in water baths at 4oC and 60oC for 15 seconds each for up to 500 thermal cycles before shear mode testing at a crosshead speed of 0.5 mm/min. Data were statistically analyzed using 3-way ANOVA and 1-way ANOVA, followed by Tukey multiple range intervals calculated at the 0.05 significance level. Fractured interfaces were analyzed by use of light microscopy and SEM. Results: Ni-Cr alloy: The bond strength of the P-OP/J50-OP group and P-TL/J50- TL group were statistically comparable (p>0,05) and exhibited greater strength than the P-MPP/J50-MPP group and P-S/J50-S (p<0,05). No significant differences were found among the four conditioners for J250 group (p>0,05), and these group showed the greater strength than the J50 group (p<0,05). After thermocycling, no significant differences (p>0,05) were found among the three primers (OP, S, TL) and the bond strength of MPP increased...(Complete abstract, click electronic access below) / Doutor

Page generated in 0.1867 seconds