• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 321
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 327
  • 199
  • 61
  • 42
  • 41
  • 40
  • 39
  • 34
  • 30
  • 29
  • 28
  • 28
  • 26
  • 26
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Degradação de filtros solares selecionados, ureia e desinfecção de água de piscina por fotoeletrocatálise combinada com ozonização / Degradation of selected sunscreen, urea and swimming pool desinfection by photoelectrocatalysis coupled with ozonation

Kim, Joaquim Yuji Usukura 08 March 2018 (has links)
Submitted by Joaquim Yuji Usukura Kim null (joaquimusukura@gmail.com) on 2018-04-06T23:09:51Z No. of bitstreams: 1 Degradação de filtros solares selecionados, ureia e desinfecção de água de piscina por fotoeletrocatálise combinada com ozonização.pdf: 3011240 bytes, checksum: 514d3af581ac1ec3ae208bd3a1a4e90a (MD5) / Approved for entry into archive by Ana Carolina Gonçalves Bet null (abet@iq.unesp.br) on 2018-04-10T17:50:32Z (GMT) No. of bitstreams: 1 kim_jyu_me_araiq_int.pdf: 2793641 bytes, checksum: daff915d2e2c443df5ecc4472e47d7cd (MD5) / Made available in DSpace on 2018-04-10T17:50:32Z (GMT). No. of bitstreams: 1 kim_jyu_me_araiq_int.pdf: 2793641 bytes, checksum: daff915d2e2c443df5ecc4472e47d7cd (MD5) Previous issue date: 2018-03-08 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O uso de protetores solares para abrandar os efeitos danosos da radiação solar à pele humana leva à contaminação da água de piscinas, o que pode ser prejudicial à saúde humana e ao ambiente. O presente trabalho investiga uma alternativa para o tratamento de piscinas usando a fotoeletrocatálise combinada à ozonização (FEC+O3). A técnica baseia-se na geração de radicais hidroxila (•OH) que podem mineralizar os compostos orgânicos a CO¬2 e H¬¬2O. Neste trabalho, a 3-benzofenona, substância amplamente utilizada em protetores solares comerciais, foi usada como composto modelo para investigação da eficiência de tratamento por FEC+O3. Monitorou-se também a degradação de ureia e a desinfecção da água usando o fungo Candida parapsilosis. Inicialmente, foram desenvolvidos reatores fotoeletrocatalíticos anulares de bolhas, onde os corantes Amarelo Ácido 1 e Azul de Metileno fora utilizados como modelos de poluentes coloridos. A melhor configuração do reator foi aquela utilizando fotoânodo de nanotubos de TiO2, contra eletrodo de DSA com grande área geométrica, lâmpada UV-B de 36 W, borbulhador de vidro sinterizado e aplicação de 2,0 V no sistema fotoeletrocatalítico. A utilização deste reator promoveu a remoção de 100 % de 3-benzofenona após 20 min de tratamento de solução contendo 30,0 mg L−1 em 0,01 mol L−1 de sulfato de sódio sob irradiação UVB de 36 W, voltagem de 2,0 V e vazão de 3,85 × 10−4 mol min−1 ¬de O¬3. Os resultados indicam que a remoção de carbono orgânico total atinge 90% após 120 min de tratamento. Do mesmo modo, a técnica alcança100% de inativação de 1,0 × 106 UFC mL−1 de Candida parapsilosis após 45 min de tratamento e remoção de mais de 90% de COT após 120 min. Soluções com até 20,0 mg L−1 de ureia não interferem na degradação do filtro solar, sendo que 50% de ureia é removida após 120 min de tratamento nestas condições experimentais. O método foi aplicado com sucesso em águas de piscina fortificadas com 3-BF 10,0 mg L−1 , ureia e Candida parapsilosis observando-se total degradação do filtro solar mesmo quando monitorado por LC-MS/MS, remoção de 90% de COT e total inativação do fungo. / The sunscreen used to minimise the harmful effects from solar radiation to the human skin leads to swimming pool water contamination, which can be harmful to human health and to the environment. The present work investigates an alternative for swimming pool treatment using photoelectrocatalysis coupled with ozonation. The technique is based on hydroxil radical generation (•OH) that can mineralize organic compounds to CO2 and H2O. Assays were done in this work with fortified water with benzophenone-3 used as model compound of sunscreens widely used in commercial sun blockers. The method yet monitored the urea degradation and the water disinfection using the fungus Candida parapsilosis. Firstly, photoelectrocatalytic reactors coupled with ozonation process were developed and for this, Yellow Acid 1 and Methylene Blue dye were used as colorful pollutant models. The best reactor configuration was the one using TiO2 nanotubes as photoanode in tube format with holes, auxiliary electrode made of DSA® with high geometric area, 36 W UVB emission lamp, sintered glass bubbler and 2,0 V applied voltage in the photoelectrocatalytic system. The reactor usage shows 100% removal of 3-benzophenone after 20 min treatment of solution containing 30.0 mg L−1 in 0.01 mol L−1 of sodium sulfate under UVB radiation, 2,0 V applied voltage and 3.85x10-4 mol min−1 O3 flow rate. The results indicate the removal of total organic carbon reach 90% after 120 minutes treatment. Likewise, the technique reached 100% of inactivation of 1.0x106 CFU mL−1 of Candida parapsilosis after 45 min treatment and more than 90% TOC removal after 120 min. Urea solutions up to 20.0 mgL−1 did not interfered in sunscreen degradation, and 50% of urea is removed after 120 min treatment in these experimental conditions. The method was successfully applied in swimming pool water fortified with 10.0 mgL−1 of benzophenone-3, urea and Candida parapsilosis, observing sunscreen total degradation even when monitored with LC-MS/MS with lower detection level, 90% TOC removal and fully fungal inactivation. / CNPQ: 134074/2016-5.
182

Efeito de desinfecções sucessivas com energia de microondas na resistência de união entre dentes artificiais e resinas para bases de próteses

Chuqui, Roberta [UNESP] 28 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-28Bitstream added on 2014-06-13T18:38:57Z : No. of bitstreams: 1 chuqui_r_me_arafo.pdf: 5214724 bytes, checksum: 7fcde9af460bda49c5c01007a97620cc (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo avaliou o efeito de desinfecções sucessivas por meio da utilização de microondas sobre a resistência de união entre dentes artificiais (incisivos centrais superiores: Biotone - DB, modelo 264 e Vivodent - DV, modelo A15) e resinas para bases (QC20 - QC, Acron MC - AC e Lucitone 550 - L). Os dentes artificiais foram posicionados em anéis de PVC (20 mm de diâmetro e 20 mm de altura) preenchidos com cera. Cada anel foi incluído em silicone por condensação para facilitar posteriormente a remoção das amostras polimerizadas. Esses moldes de silicone foram então incluídos em mufla dental com gesso. A cera foi eliminada com água em ebulição, sendo o molde preenchido com resina acrílica, manipulada e polimerizada de acordo com as instruções do fabricante. Quarenta corpos-de-prova foram obtidos para as três resinas de base com as duas marcas de dentes avaliados. Todas as amostras foram divididas aleatoriamente em quatro grupos. G1 (controle) - amostras imersas em água destilada a 37ºC por 48 horas; G2 - imersas por 48 horas e submetidas a dois ciclos de desinfecção por 6 minutos a 650 W; G3 - imersas por 48 horas em água destilada e submetidas a sete ciclos de desinfecção (um por dia) por 6 minutos a 650 W, estando as amostras imersas em água a 37ºC entre as desinfecções; G4 - imersas em água destilada por 8 dias (controle). O teste de cisalhamento foi realizado em máquina de ensaios MTS - 810 com a força aplicada na superfície palatina dos dentes em ângulo de 45º e velocidade de 0,5 mm/min. As superfícies de fratura foram observadas em lupa esteroscópica com um aumento de 10 vezes para determinar a natureza da falha (adesiva, coesiva ou mista). Adicionalmente, foi realizada microscopia eletrônica de varredura. Os dados (MPa) foram analisados utilizando ANOVA, teste de Tukey e teste t de Student (P=0,05)... / This study evaluated the effect of microwave disinfection on the bond strength of denture teeth (maxillary central incisors: Biotone - DB, model 264 and Vivodent - DV, model A15) to acrylic resins (QC20 - QC, Acron MC - AC and Lucitone 550 - L). Denture teeth were positioned within polyvinylchloride tubes (20 mm diameter and 20 mm length) filled with melted wax. The tubes were invested in silicone rubber to facilitate removal of the processed specimens from the flask. These silicone moulds were then invested in the usual denture flasks in dental stone. The wax was boiled out, the mould was packed with denture resin and polymerized according to the manufacturer's instructions. Forty specimens were formed from each of the three denture base resin with the two brands of denture teeth. All specimens were randomly divided into four groups to provide a sample size of 10. G1 (control group) - immersed in distilled water at 37ºC for 48 hours; G2 - immersed in distilled water at 37ºC for 48 hours and microwaved twice at 650W for 6 minutes; G3 - immersed in distilled water at 37ºC for 48 hours and microwaved (650 W for 6 minutes) daily for 7 days, being stored in water at 37ºC between exposures; G4 (control group) - immersed in distilled water at 37ºC for 8 days. Shear load was applied with a load testing machine at 45 degrees from the long axis of each denture tooth on the palatal surface at a crosshead speed of 0.5mm/min until fracture. Fracture surfaces were evaluated with an optical stereomicroscope under x 10 magnifications to determine the nature of the failure (adhesive, cohesive or combination). In addition, a representative sample of each experimental group was evaluated with a scanning Electron Microscopy (SEM). The data (MPa) were analyzed statistically using 3-way ANOVA, Tukey's test and Student's t test (P=0.05)...(Complete abstract, click electronic address below)
183

Efeito da irradiação por microondas sobre as propriedades viscoelásticas de resinas para base de prótese e reembasamento

Lombardo, Carlos Eduardo Leão [UNESP] 25 March 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-03-25Bitstream added on 2014-06-13T19:38:22Z : No. of bitstreams: 1 lombardo_cel_me_arafo.pdf: 3996119 bytes, checksum: c7eb8e08977bab50ee60b2bacfeaab4e (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo avaliou o efeito da irradiação por microondas e da armazenagem em água sobre as propriedades viscoelásticas de duas resinas para base de prótese (Lucitone 550- L e Vipi Wave- VW) e duas resinas para reembasamento imediato (Kooliner- K e Tokuyama Rebase Fast II- TR II). Oito corpos-de-prova (40 x 10 x 3,3 mm) de cada material foram avaliados por meio de análise térmica dinâmico-mecânica (DMTA) após: acabamento (controle 1), armazenagem em água por 7 dias (controle 2), um (MW1) e 7 ciclos de irradiação por microondas (MW7). Para cada corpo-de-prova, ciclos de DMTA foram realizados dentro de intervalos de temperatura diferentes. Os valores do módulo de armazenamento (E’) e de amortecimento mecânico (tan δ) a 37ºC foram obtidos no primeiro e último ciclos de DMTA. A partir do último ciclo, os valores de E’ na temperatura de transição vítrea (Tg) e o máximo de tan δ também foram obtidos. Os dados foram submetidos à análise de variância a dois critérios e ao teste de Student-Newman-Keuls (α=0,05). Além disso, mensurações de temperatura no interior de corpos-de-prova de cada material, durante a irradiação por microondas (650 W/ 3 min), foram realizadas por meio da utilização de sensor de fibra óptica. Seis corpos-de-prova de cada material foram avaliados. Durante a irradiação por microondas, todos os corpos-de-prova atingiram a temperatura de ebulição da água em aproximadamente 130 s. A partir do primeiro ciclo de DMTA, MW 1 e controle 2 aumentaram significantemente os valores de E’ e reduziram os valores de tan δ de K a 37ºC (P<0,05). No último ciclo de DMTA, o tan δ de K e TR II foi significantemente reduzido após MW1 (P<0,05). MW7 reduziu os valores de tan δ de K (P<0,05). Os valores de E’ de L e VW foram semelhantes entre si e superiores aqueles produzidos por K e TR II (P<0,05). Na Tg, K produziu o menor E’ e seu máximo... / This study evaluated the effect of microwave irradiation and water storage on the viscoelastic properties of two denture base resins (Lucitone 550-L and Vipi Wave-VW) and two reline resins (Kooliner-K and Tokuyama Rebase Fast II-TR II). Eight specimens (40x10x3.3mm) of each material were evaluated by dynamic mechanical thermal analysis (DMTA) after: processing, water storage for 7 days (WS), one (MW1) and 7 cycles of microwave irradiation (MW7). For each specimen, DMTA runs were carried out within different temperature intervals. Values of storage modulus (E’) and loss tangent (tan δ) at 37ºC were obtained from the first and last runs. From the last run, values of E’ at the glass transition temperature (Tg) and maximum tan δ were also recorded. Data were analyzed by 2-way ANOVA followed by Student-Newman-Keuls test (α=0.05). In addition, measurements of the inside temperature of each specimen during microwave irradiation (650W/3min) were conducted using a fiber optic temperature sensor. Six specimens of each material were evaluated. During microwave irradiation, all specimens reached the boiling temperature of water at approximately 130 s. From the first DMTA run, MW1 and WS significantly increased the E’ and decreased the tan δ of K at 37°C (P<0.05). From the last run, the tan δ of K and TR II was significantly decreased after MW1 (P<0.05). MW7 decreased the tan δ of K (P<0.05). The E’ of L and VW was similar and higher than K and TR II (P<0.05). At Tg, K produced the lowest E’ and its maximum tan δ was increased after MW1 (P<0.05). The Tg mean values were arranged as: L>VW>TR II>K (P<0.05). Microwave irradiation and WS did not detrimentally affect the viscoelastic properties of the denture base and reline resins evaluated.
184

Efetividade da desinfecção de próteses totais por energia de microondas no tratamento da estomatite protética associada à Candida spp /

Neppelenbroek, Karin Hermana. January 2005 (has links)
Resumo: O presente estudo avaliou a efetividade da desinfecção de próteses totais no tratamento de estomatite protética associada à Candida spp. Sessenta pacientes com estomatite protética foram divididos em quatro grupos de acordo com o tratamento instituído: G0 (controle)- foram orientados a escovarem suas próteses com sabão de coco e dentifrício, deixando-as imersas em água durante a noite; G1- as próteses totais superiores dos pacientes foram irradiadas por microondas (650 W/ 6 minutos), três vezes por semana, durante 30 dias; G2- os pacientes receberam o mesmo tratamento do G1 associado à aplicação tópica de miconazol três vezes ao dia, por 30 dias; G3- apenas receberam terapia antifúngica tópica com miconazol de acordo com a prescrição indicada ao G2. Antes do início do tratamento, exames citológicos por esfregaço e culturas micológicas quantitativas foram obtidos da superfície interna das próteses totais superiores e da mucosa palatina de suporte de todos os pacientes. Os esfregaços e as culturas foram repetidos durante (15 dias), ao final do tratamento (30 dias) e após a sua suspensão (30 e 60 dias). Para a avaliação clínica, foram realizadas fotografias da mucosa palatina dos pacientes em cada consulta. Utilizou-se o teste de qui-quadrado (?2) para determinar diferenças entre os tratamentos dos grupos de estudo. A influência de fatores predisponentes na efetividade dos tratamentos também foi avaliada estatisticamente. Nos períodos durante (15 dias) e imediatamente após o tratamento (30 dias), os esfregaços citológicos e culturas quantitativas referentes à mucosa palatina e a superfície interna das próteses dos pacientes dos Grupos 1 e 2 não demonstraram formas miceliais e colônias viáveis de Candida spp. Em até 60 dias após a suspensão do tratamento, não foram observadas... (Resumo complet, clicar acesso eletrônico abaixo) / Abstract: The present study evaluated the effectiveness of microwave disinfection of complete dentures on the treatment of Candida-related denture stomatitis. Sixty patients with denture stomatitis were divided into four treatment groups: G0 (control)- patients were instructed to scrub their dentures with coconut soap and toothpaste and soak them in water overnight; G1- patients had their maxillary denture microwaved (650 W/6 minutes) three times per week for 30 days; G2- patients received the treatment of G1 in conjunction with topical application of miconazole three times per day for 30 days; G3- patients received the same course of topical antifungal therapy with miconazole of G2. Before treatment, cytological smears and quantitative mycological cultures were taken from the tissue side of each maxillary denture and the corresponding palatal mucosa of all patients. Smears and cultures were repeated during (15 days), immediately after (30 days) and follow-up after the treatment (30 and 60 days). At each trial, palatal tissues of patients were photographed for clinical evaluation. Chi-squared statistical test (?2) was used to differentiate between the treatment groups. The influence of predisposing factors on treatment effectiveness was also analyzed statically. During (15 days) and immediately after the treatment (30 days), cytological smears and quantitative cultures of palatal mucosa and denture tissue surface of G1 and G2 patients did not exhibit mycelial forms and colonies of Candida spp. Following the treatment phase (30 and 60 days), no mycelial forms were found on smears of palatal mucosa of G1 and G2 patients. However, over the 60-day observation period following treatment, five patients in the G1 (33.33%) and six patients of G2 (40%) showed recurrence of mycelial forms of Candida spp. on the tissue surfaces of... (Complete abstract, access undermentioned electronic address) / Orientador: Ana Cláudia Pavarina / Coorientador: Elaine Maria Sgavioli Massucato / Coorientador: Denise Madalena Palomari Spolidorio / Coorientador: Luís Carlos Spolidorio / Banca: Dalva Cruz Laganá / Banca: Helena de Freitas Oliveira Paranhos / Banca: Carlos Eduardo Vergani / Banca: Ana Lucia Machado / Doutor
185

Efetividade microbiológica da desinfecção por microondas e seus efeitos sobre a dureza de materiais reembasadores macios /

Pavan, Sabrina. January 2006 (has links)
Resumo: O objetivo deste estudo foi avaliar a efetividade da desinfecção utilizando energia por microondas sobre os materiais reembasadores macios Mollopast-B e Ufi Gel P contaminados com os microorganismos C. albicans, S. aureus, B. subtilis e P. aeruginosa. Além disso, foi analisado o efeito desta técnica na dureza dos materiais reembasadores macios. Para avaliar a efetividade da desinfecção, foram confeccionados 200 corpos-de-prova de cada material sobre bases de resinas termopolimerizadas seguindo as instruções dos fabricantes. Os corpos-de-prova foram imersos meio de cultura TSB inoculados com os microrganismos C. albicans, S. aureus, B. subtilis e P. aeruginosa e submetidos à desinfecção em microondas pelos tempos de 3, 4, 5 e 6 minutos a potência de 650W. Alíquotas da suspensão resultante das diluições seriadas de 10-2-10 -5 foram semeadas em placas de petri e após 48 h de incubação o número de colônias foi calculado (ufc/mL). Para a avaliação do efeito da desinfecção com energia por microondas sobre a dureza dos materiais, 40 corpos-de-prova de cada reembasador macio foram submetidos aos diferentes tempos de desinfecção em microondas (3, 4, 5 e 6 min). As mediadas de dureza foram realizadas com um durômetro shore A em diferentes períodos: imediatamente após a confecção dos corpos, 24, 48 h e após 7 dias. Os dados obtidos foram submetidos à Análise de Variância e ao teste de Tukey (p<0,01). Os resultados obtidos mostraram que: a - os tempos de 4, 5 e 6 minutos de irradiação com energia por microondas esterilizou os corpos-de-prova dos materiais Molloplast B e Ufi Gel P; b - 3 minutos de irradiação promoveu a desinfecção dos corpos-de-prova do material Molloplast B contaminados com B. subtilis, S. aureus e P. aeruginosa; c - a dureza apresentou maiores alterações nos tempos de desinfecção 5 e 6 min. / Abstract: The aim of this study was to evaluate the effectiveness of different times of exposure in microwave to disinfect two long-term soft lining materials (Molloplast B and Ufi Gel P) and the effects of this method on the hardness of these materials. Specimens of soft liners were made on an acrylic denture base resin and individually inoculated with C. albicans, S. aureus, B. subtilis and P. aeruginosa. After 24 hours at 37º C, 160 specimens of each material were individually submitted to microwave irradiation at 650 W for 3, 4, 5 and 6 minutes. Forty specimens were used as positive controls. Replicated specimens were plated on selective media appropriate for each microorganism. After incubation at 37ºC for 48 hours, colonies counts were quantified for each plated specimens (ufc/mL). To evaluate the effects of disinfection with microwave energy at different times of exposure on the hardness, fifty rectangular specimens (36 x 7 x 6 mm in thickness) were made for each material. Ten samples of each material were immersed in 200 mL of distilled water and disinfected in a microwave oven for 3, 4, 5 and 6 minutes at 650 W. The specimens were microwaved twice and hardness values were obtained with a Shore A durometer at different times: immediately after specimen fabrication and after 24, 48 hours and 7 days. Control specimens of each material were not disinfected and were maintained in distilled water during the role experimental period. Data were submitted to ANOVA and Tukey's test (p<0.01). The results showed that: a- sterilization was obtained at 6, 5 and 4 minutes of microwave irradiation for all specimens relined with Ufi Gel P and Molloplast B contaminated with all microorganisms; b- the specimens relined with Molloplast B contaminated with B. subtilis, S. aureus and P. aeruginosa and irradiated for 3 minutes demonstrated growth after incubation; c- the 6 minutes of microwave disinfection promoted the lower shore A hardness mean values for Molloplast. / Orientador: João Neudenir Arioli Filho / Coorientador: Denise Madalena Palomari Spolidorio / Banca: Helena de Freitas Oliveira Paranhos / Banca: Marcelo Ferraz Mesquita / Banca: Wirley Gonçalves Assunção / Banca: Francisco de Assis Mollo Junior / Doutor
186

Estudo para minimização do processo de fumigação empregado na limpeza e desinfecção de salas limpas em Bio-Manguinhos/ FIOCRUZ / Study for minimization of the process of fumigation used in the cleanness and disinfection of clean rooms in Bio-Manguinhos/FIOCRUZ

Stella Martins Patitucci 16 January 2008 (has links)
As indústrias farmacêuticas que utilizam salas limpas, em seus processos produtivos, devem controlar ao máximo o nível de contaminantes microbiológicos, baseada na legislação RDC 210 que determina o cumprimento das diretrizes estabelecidas no Regulamento Técnico das Boas Práticas para a Fabricação de Medicamentos. Diante deste cenário, a proposta deste trabalho é avaliar o processo de fumigação com o reagente formaldeído, para a limpeza e desinfecção de salas limpas do Instituto de Tecnologia de Imunobiológicos Bio-Manguinhos. Então, foram desenvolvidas as seguintes etapas: diagnóstico com as indústrias farmacêuticas para traçar um perfil quanto ao uso da fumigação; quantificação de resíduos gerados; avaliação da exposição dos operadores ao formaldeído que é cancerígeno e acompanhamento dos resultados do monitoramento ambiental do ar e de superfícies, inicialmente na sala limpa do SEFBC, cuja atividade principal é a formulação de vacinas bacterianas e biofármacos, após a implantação do espaçamento da fumigação. Os resultados discutidos na presente dissertação mostraram, que a maior parte das indústrias farmacêuticas, não realiza a desinfecção por intermédio da fumigação e que o resíduo gerado neste processo é o mais crítico. E, sobretudo, o monitoramento microbiológico do ar e de superfícies da sala limpa do SEFBC, a partir da metodologia adotada de espaçamento da fumigação, comprovou que não é necessário o emprego deste processo de forma rotineira, para garantir os níveis exigidos de limpeza e desinfecção da respectiva área / Pharmaceutical industries that use clean rooms for their productive processes, must control to a maximum the level of microbiological contaminants, based on RDC 210 legislation that determines the fulfillment of lines in the directions established by the Technical Regulation Program for a Good Medicine Manufacturing. Ahead to this scene, the purpose of this work was to evaluate the process of fumigation with reacting formaldehyde, for the cleanness and disinfection of clean rooms of the Bio-Manguinhos Institute of Technology of Imunobiológicos. Then, the following stages had been developed: diagnosis with the pharmaceutical industries in order to get a scenario on the use of fumigation; quantification of the residues generated; evaluation of the exposition of operators to formaldehyde, a cancerigenous agent, and screening of the results of the environment monitoring of the air and surfaces, initially in the clean room of the SEFBC, in the areas of biopharmaceuticals formulation, and after a proper implementation of a fumigation process, at pre-defined intervals. The results thus obtained showed that most of the pharmaceutical industries no longer use disinfection for fumigation and that the residues generated in this process is the most critical problem. The overall microbiological monitoring of the air and surfaces of SEFBC clean room, according to the proposed methodology for fumigation, proved that the use of this process as a routine is not essential to guarantee the demanded levels of cleanness and disinfection of the respective areas
187

Avaliação de métodos alternativos utilizando o corante lissamina green B (C.I. 44090) para a determinação de dióxido de cloro em processos de tratamento de água

Martins, Aline de Oliveira January 2007 (has links)
Made available in DSpace on 2013-08-07T18:54:31Z (GMT). No. of bitstreams: 1 000393354-Texto+Completo-0.pdf: 726579 bytes, checksum: d7c29233cb1df65bec37a23c4be59ca5 (MD5) Previous issue date: 2007 / At present the use of alternative disinfectants to chlorine in the water treatment is increasing due to the generation of the undesirable disinfection by-products, as trihalomethanes and haloacetic acids in conventional treatment. The chlorine dioxide (ClO2) has been detached in the last years as disinfecting assistant in the drinking water treatment plants (WTPs) due to its chemical characteristics and the possibility of being generated in situ. However, the use of this disinfectant could generated by-products among then chlorite ion (ClO2 -) considered potentially harmful to the human health, owning maximum level of tolerance of 0. 20 mg L-1 determined by the Brazilian standards. In this context, it is important the evaluation and the improvement of the precise and sensitive analytical techniques adapted to the complexity of the different samples. Recently, the EPA method 327. 0 was proposed specifically for determination of chlorine dioxide and chlorite in treated waters. This spectrophotometric method uses a colored solution (lmax = 633 nm) of Horseradish Peroxidase, an enzyme that catalyses the conversion reaction of chlorite to chlorine dioxide, and the dye Lissamine Green B which quickly and selectively reacts with ClO2 proportionally reducing the solution absorbance in the visible region. The quantification of the ClO2 is done by external calibration and the chlorite concentration is obtained by difference, by the analysis of a second sample aliquot from which chlorine dioxide was previously sparged using an inert gas. In this context, the aims of this works are the EPA 327. 0 method implementation to analyses chlorine dioxide and chlorite through the water treatment plant and the finished drinking water, as well as the method optimization to analysis ClO2 concentrated solutions (generated in WTPs) and its presence as contaminant on standard chlorite solutions. The obtained results indicated that EPA method 327. 0 is adequate to ClO2 analysis in drinking waters, but the presence of this compounds was not observed in these kinds of samples. On the other hand, the method is not satisfactory to chlorite determination in these samples presenting a high quantification limit (0. 20 mg L-1). It is not recommended the use of the method to following the treatment processes due to the water characteristics (color, turbidity, dissolved solid and among others) that influences the spectrometric analyses and could not be eliminated by usual procedures. In function of theses limitations, the method was optimized by the enzyme elimination and several modifications on analysis procedures (dye concentration, change order and volumetric measurements of the reagents and samples, dilutions, reaction time, optical path, among others). With these changes was possible to quantify adequately high ClO2 concentration (>100 mg L-1) as well as the presence of this compound as contaminant (< 1 mg L-1) of the concentrated chlorite solutions (1,000 mg L-1). Then, it developed a method precise and quickly that permit to adapt analytic parameters as concentration of the reagents, volume of sample and time of reaction, it enables the chlorine dioxide analysis in different matrices. / Atualmente é crescente o uso de desinfetantes alternativos ao cloro no tratamento de águas devido à geração de subprodutos indesejáveis, como os trihalometanos e os ácidos haloacéticos no processo de desinfecção convencional. O dióxido de cloro (ClO2) vem se destacando nos últimos anos como desinfetante auxiliar nas estações de tratamento de água (ETAs) devido as suas características químicas e de sua geração in situ. Entretanto, o uso desse desinfetante pode gerar subprodutos dentre os quais se destaca o íon clorito (ClO2-), potencialmente prejudicial à saúde humana, possuindo limite máximo de tolerância de 0,2 mg L-1 estabelecido pela legislação brasileira. Neste contexto, é importante a avaliação e o aprimoramento de técnicas analíticas sensíveis, precisas e adaptadas à complexidade de diferentes amostras. Recentemente, o método EPA 327. 0 foi proposto especificamente para análise de ClO2 e ClO2- em águas tratadas. Esse método espectrofotométrico utiliza uma solução colorida (λmax = 633 nm) contendo Horseradish Peroxidase, enzima que catalisa a reação de conversão do íon clorito em dióxido de cloro, e o corante Lissamine Green B que reage rapidamente e seletivamente com o ClO2 reduzindo proporcionalmente a absorção da solução na região do visível. A quantificação do ClO2 é feita por calibração externa e a concentração do clorito é obtida por diferença, através da análise de uma segunda alíquota na qual o dióxido de cloro é previamente retirado por borbulhamento com um gás inerte. Neste contexto, os objetivos desse trabalho são implantar o método EPA 327. 0 para análise de dióxido de cloro e do íon clorito ao longo do processo de tratamento, bem como otimizá-lo para análises de ClO2 em soluções concentradas e como contaminante em soluções padrão do íon clorito. Os resultados obtidos indicaram que o método EPA 327. 0 é adequado para a análise de ClO2 em água potável, porém não se verificou sua presença nesse tipo de amostras. Por outro lado, o método não é satisfatório para a determinação do íon clorito nessas amostras apresentando um limite de quantificação elevado (0,2 mg L-1). Não é recomendada a utilização desse método para o acompanhamento das concentrações dos analitos durante o processo de tratamento devido à variabilidade nas características (cor, turbidez, sólidos dissolvidos, entre outras) da água gerando artefatos na análise espectrofotométrica que não podem ser corrigidos por procedimentos usuais. Em função dessas limitações, o método foi otimizado com a eliminação da enzima e com modificações nos procedimentos de análise (concentração do corante, adoção de medida volumétrica e mudança na ordem da adição de reagentes e amostras, diluições, tempo de reação, caminho óptico, entre outros). Com as alterações propostas foi possível quantificar o dióxido de cloro tanto em elevadas concentrações (> 100 mg L-1) bem como sua presença como contaminante (< 4,5 mg L-1) em soluções concentradas (1000 mg L-1) do íon clorito. Assim, desenvolveu-se um método preciso e rápido que permite adequar parâmetros analíticos como concentração dos reagentes, volume de amostra e tempo de reação, possibilitando a análise de dióxido de cloro em diferentes matrizes.
188

Produção de água eletrolisada ácida para uso em odontologia

Campregher, Ulisses Bastos January 2011 (has links)
O objetivo desse trabalho foi desenvolver um aparelho experimental de baixo custo para produção de água eletrolisada ácida (AEA) e verificar sua eficácia na desinfecção de resina acrílica termo polimerizável (RA). Além disso, verificou-se a influência da AEA nas seguintes propriedades da RA. Sorção, Solubilidade, Resistência Flexural, Microdureza Knoop e Rugosidade Superficial. A AEA foi produzida através do processo de eletrólise de uma solução de NaCl a 5% numa célula eletrolítica de dois compartimentos separados por uma membrana semipermeável. Foram utilizados eletrodos de grafite e a diferença de potencial aplicada entre eles foi de 30 V, gerada por um alimentador com capacidade máxima de corrente de 2 A. Após 20 minutos de eletrólise a solução anódica (AEA) apresentou os seguintes parâmetros: pH 3,0 e potencial de óxi-redução de 1150 mV. O tempo de imersão na solução para o ensaios de desinfecção bem como os de propriedades características da RA foi de 10 minutos. A AEA foi eficaz na desinfecção da RA pois os corpos desinfectados não provocaram a turvação dos meios de cultura. A imersão em AEA aumentou estatisticamente (p<0,05) a sorção e a solubilidade da resina acrílica, porém os valores permaneceram dentro dos parâmetros estabelecidos pela ISO 1567. As demais propriedades da resina ficaram inalteradas (p>0,05). / The aim of this research was to develop a low cost experimental apparatus able to produce Electrolyzed Acidic Water (EAW) and verify its efficacy for disinfection of a denture base acrylic resin (AR). It was also verified the influence of EAW on the following properties of AR: Sorption, Solubility, Flexural Strength, Knoop Hardness and Superficial Rugosity. EAW was produced through an electrolysis process of an aqueous NaCl solution (5%) in an electrolytic two chambers cell with a separation membrane between the chambers. Graphite electrodes were used and the potential difference between them was 30 V, provided by a power supply with maximum amperage capacity of 2 A. 20 minutes after the begging of the electrolysis process the anodic solution (EAW) showed the following parameters: pH 3.0 and oxidation-reduction potential (ORP) of 1150 mV. The immersion time in the solution for the disinfection test and also for the evaluation of AR properties was 10 min. EAW was able to disinfect AR as the infected specimens did not cause turbidity of the culture medium. Immersion in EAW increased the sorption and decreased the solubility of the AR in a statistically significant way (p<0.05) but it was within the range required by ISO 1567. All the other AR properties suffered no changes (p<0.05)
189

Influência da desinfecção de elastômeros com ácido paracético e água eletrolisada ácida / Influence of desinfection of elastomers with peracetic acid and acid electrolized water

Paulus, Marília January 2013 (has links)
O objetivo deste estudo foi avaliar a eficácia de duas soluções desinfetantes, ácido peracético e água eletrolisada ácida (AEA), na desinfecção de dois elastômeros, e a influência em suas propriedades de reprodução de detalhes e compatibilidade com o gesso. Um poliéter e uma silicona de adição foram manipulados, e a impressão de uma matriz apresentando três linhas (20, 50 e 75μm) de espessura e 25 mm de comprimento foi realizada. Após, os espécimes (n=3) foram imersos nas soluções de água destilada, glutaraldeído 2%, ácido peracético 0,2% e água eletrolisada ácida durante 10 minutos e, em seguida, o gesso tipo IV foi vazado sobre a impressão. Os materiais foram avaliados quanto à reprodução de detalhes e compatibilidade com o gesso. Posteriormente, biofilmes de Sthaphylococcus aureus foram cultivados sobre os espécimes durante 24 horas a 37°C. Após, os espécimes foram imersos durante 10 minutos nas soluções a seguir: solução salina estéril 0,89%, glutaraldeído 2%, ácido peracético 0,2% e água eletrolisada ácida. O biofilme presente em cada espécime foi coletado, diluído e alíquotas das diluições foram inoculadas em meio ágar sangue. Depois de 24 horas de incubação a 37°C, foi realizada a contagem do número de unidades formadoras de colônias bacterianas em cada um dos espécimes. Na reprodução de detalhes os resultados foram satisfatórios, pois a linha de 20 μm foi reproduzida em todos os espécimes. No teste de compatibilidade com o gesso, todos os grupos reproduziram a linha de 50 μm em todo o comprimento de 25 mm. Na análise antimicrobiana, os resultados mostraram que houve crescimento nos espécimes imersos em solução salina estéril (grupo controle negativo). Entretanto, não houve crescimento bacteriano nos espécimes imersos na solução de glutaraldeído 2%, ácido peracético 0,2% e AEA (p<0,001). Com base na metodologia realizada, concluiu-se que o ácido peracético e a água eletrolisada ácida não alteraram as propriedades dos elastômeros avaliados, e mostraram-se eficazes no processo de desinfecção destes materiais. / The aim of this study was to evaluate the efficacy of two disinfecting solutions (peracetic acid and acid electrolyzed water) in two elastomeric materials and the influence on its detail-reproduction properties and gypsum compatibility. Polyether and vinyl polysiloxane were handled, and impression of a metal mould with three lines (20, 50 and 75μm wide and 25mm long) was performed. After this, the impressions (n=3) were immersed in the following solutions, for 10 minutes: distilled water, glutaraldehyde 2%, peracetic acid 0,2% and acid electrolyzed water and then type IV gypsum was poured on the impression. The materials were evaluated as to detail reproduction the gypsum compatibility. Subsequently specimens were immersed for 10 minutes into the following solutions: 0.89% sterile saline solution, 2% glutaraldehide, 0.2% peracetic acid, and acid electrolyzed water. The biofilm in each sample was collected and diluted, and the aliquots of the dilution were inoculated in blood agar. After 24h incubation at 37°C, the colony forming units (CFU) were calculated. In the detail reproduction the results were satisfactory, as the 20 μm line was reproduced in all specimens. All specimens presented detail reproduction and gypsum compatibility after immersion. In the antimicrobial analysis, the results showed that the specimens immersed in sterile saline solution grew (negative control group). On the other hand, there was no bacterial growth in the specimens immersed in 2% glutaraldehyde, 0.2% paracetic acid, and acid electrolyzed water (p<0.001). Based on this study methodology, it is concluded that both peracetic acid and acid electrolyzed water did not influence the detail reproduction and gypsum compatibility were efficient in disinfecting the elastomeric materials.
190

Tratamento de efluente de reator anaeróbio de manto de lodos de fluxo ascendente (UASB) por flotação não convencional e desinfecção ultra-violeta

Tessele, Fabiana da Silva January 2011 (has links)
Esta tese apresenta o estudo e aplicação de uma alternativa para o tratamento de águas residuárias municipais mediante integração de técnicas compactas de tratamento, visando adequar a qualidade do esgoto tratado às exigências ambientais, prevenir a eutrofização dos recursos hídricos e produzir água de boa qualidade para reúso em diversos fins, propiciando uma fonte alternativa de água. Para isso, foi projetada e construída uma estação de tratamento de esgotos domésticos, em escala piloto, que inclui um reator biológico anaeróbio (tipo UASB), seguido des flotação em dois estágios, para remoção adicional de matéria orgânica residual e nutrientes com obtenção de lodos separados (orgânico e inorgânico) e polimento final oxidativo (radiação ultravioleta). A qualidade da água obtida pelo sistema UASB e flotação em dois estágios foi comparada com a obtida pelo tratamento do efluente anaeróbio em uma lagoa de polimento, sistema largamente difundido no Brasil e outros países de clima ameno. A qualidade da água obtida em ambos os sistemas foi comparada com a requerida para reúso em diversos fins. O processo empregado potencializa o reaproveitamento dos resíduos sólidos, dentro do conceito de recuperação da matéria orgânica e nutrientes. Os resultados são discutidos em termos dos parâmetros biológicos, físico-químicos e operacionais envolvidos. / This thesis presents the study and application of an alternative for the treatment of municipal wastewater through the integration of compact treatment techniques, aiming at improving the quality of treated sewage to meet environmental requirements, prevent eutrophication of water resources and produce good quality water for reuse in various purposes, providing an alternative source of water. It was designed and built a wastewater treatment of domestic sewage in a pilot scale, which includes an anaerobic biological reactor (UASB type), followed by flotation in two stages to obtain separated sludges (organic and inorganic) and final disinfection (ultraviolet radiation). The quality of water obtained by UASB system and two stages flotation followed by UV was compared with that obtained by treatment of anaerobic effluent polishing pond system, widespread in Brazil and other countries with mild climatic conditions. The quality of water obtained in both systems is compared to that required for reuse in different purposes. The process employed enhances the recycling of solid waste within the concept of recovery of organic matter and nutrients. The results are discussed in terms of biological, physical, chemical and operational involved.

Page generated in 0.0691 seconds