• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 321
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 327
  • 199
  • 61
  • 42
  • 41
  • 40
  • 39
  • 34
  • 30
  • 29
  • 28
  • 28
  • 26
  • 26
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
321

Desenvolvimento de um biosensor para mensuração de deformações mecânicas em tecidos ósseos

Karam, Leandro Zen 21 May 2015 (has links)
CNPQ / O presente trabalho tem como objetivo o desenvolvimento de um biosensor, utilizando redes de Bragg em fibras óticas, capaz de mensurar deformações em tecido ósseo. Inicialmente foram realizados testes de esterilização e desinfecção com sensores, após o processo completo, os sensores foram testados quanto a sua sensibilidade. Com isso os métodos de esterilização e desinfecção autoclave, óxido etileno, hipoclorito de sódio, cloramina T e ácido peracético, foram eficazes para eliminação e ou inativação dos microrganismos, sem que haja alterações no comportamento das FBGs. Com isso definem-se métodos aplicáveis para possíveis estudos, onde fibras óticas foram implantadas em animais in vivo para estudos de comportamento metabólico com a presença de materiais inorgânicos. Na continuidade dos trabalhos foram realizados testes de compatibilidade de fibras óticas inseridas no tecido subcutâneo de ratos. Baseado na análise descritiva dos cortes histológicos pode-se concluir que as fibras ópticas sem revestimento e com revestimento foram biocompatíveis quando implantadas em subcutâneo de ratos. Sendo assim, foi possível contemplar o desenvolvimento de um sensor baseado em redes de Bragg em fibras óticas para implantação direta no tecido ósseo. Posteriormente foram realizados testes-piloto para o desenvolvimento da metodologia de construção e implante no desenvolvimento de biosensores. Com todo o trabalho feito até à data, o desenvolvimento e construção de um biosensor que foi implantado in vivo foi possível. O biossensor foi fixado na região mandibular de um bovino quatro meses de idade. Uma semana após a implantação, os animais receberam diferentes tipos de alimentos e foi monitorizada durante a ingestão de alimentos. Com as deformações medidas foi possível a análise dos diferentes padrões mastigatórios e diferentes magnitudes de força e frequência mastigatória que o animal desempenhada durante o processo de mastigação. / This study aims to develop a biosensor using Bragg gratings in optical fibers, capable of measuring deformation in bone tissue for this took a lot of work. Initially sterilization and disinfection with sensors tests were performed after the entire process, the sensors were tested for their sensitivity. In the same study methods of sterilization and disinfection have been tested to assess its efficiency. Thus methods of sterilization and disinfection autoclave, ethylene oxide, sodium hypochlorite, chloramine T and peracetic acid were effective for removing or inactivating microorganisms and, without changes in the behavior of the FBGs. With this set up methods applicable for possible studies, where optical fibers are implanted in in vivo animal studies metabolic behavior in the presence of inorganic materials. Continuing the work was carried out optical fiber compatibility tests inserted in the subcutaneous tissue of rats. Based on the descriptive analysis of histological sections can be concluded that the optical fiber uncoated and coated were biocompatible when implanted in rat subcutaneous tissue. Thus it is possible to contemplate the development of a sensor based on Bragg gratings in optical fibers for direct implantation into the bone tissue. Following on from the work were carried out pilot tests for development of construction methodology and implant in biosensor development. With all the work done to date, the development and construction of a biosensor that was implanted in vivo was possible. The biosensor was fixed in the mandibular region of a bull four months old. A week after implantation, the animal received different types of food and was monitored during the intake of foods. With the deformations measured parse the different masticatory patterns and different magnitudes of force and masticatory frequency that the animal developed during the chewing process completing the objectives of this study.
322

FERRAMENTA PARA IMPLEMENTAÇÃO DOS REQUISITOS HIGIÊNICO-SANITÁRIOS EM SERVIÇOS DE NUTRIÇÃO E DIETÉTICA HOSPITALAR / TOOL FOR IMPLEMENTATION OF HYGIENIC-SANITARY REQUIREMENTS IN NUTRITION AND DIETETICS HOSPITAL SERVICES

Stangarlin, Lize 24 March 2014 (has links)
The goal of this study was to develop a quality tool for Nutrition and Dietetics Hospital Services and evaluate the hygienic sanitary conditions of these places before and after the implementation of this tool, according to the view of the internal and external auditor. Also, to evaluate the satisfaction of the internal auditors regarding the tool, check the hygienic sanitary conditions of the hands of manipulators and surfaces in contact with food after improvements and training and evaluate the satisfactionf the patients regarding the meals served after implementation of the tool. This research was divided in three studies (1 - preparation and implementation of the tool; 2 - Review of the hygienic sanitary conditions of the hands and contact surfaces; 3 - evaluation of the satisfaction of patients regarding the meals served). The sample was composed by 15 Nutrition and Dietetics Hospital Services. To establish the quality tool, we used the requirements of the laws and regulations of Brazil. The tool is composed by four support instruments, divided in: 1 - Evaluation and quality planning; 2 - A guide for the development of the Manual of Best Practices; 3 - A guide for the development of Standard Operating Procedures and Instrument; 4 - A guide for the development of the Essential Operational Controls. After the development of the tool, we performed an initial evaluation of the hygienic sanitary requirements at each site through the application of the Instrument 1 by the internal and external auditor. The technician responsible for the Nutrition and Dietetics Hospital Services was considered the internal auditor and the external auditor was a professional with experience in the food area, which evaluated all the locations. After the implementation, the internal auditors received the results of the external auditor and other instruments of the tool, and the deadline of one year for the implementation was stipulated. At the end of the deadline, the internal and external auditors applied again the instrument 1. Then, the internal auditors completed a questionnaire to evaluate their satisfaction regarding the quality tool. The evaluation of the hygienic sanitary conditions of the hands and contact surfaces was divided into two stages. First, we evaluated the requirements of hygiene and microbiological analyzes on hands and contact surfaces. Then, the locations received the results and recommendations of adequacy, which were asked to be fulfilled in two months. After this, the local that showed improvements participated in the second stage, with training and new collection of microbiological analyzes. To evaluate the satisfaction of the patients regarding the meals served, we prepared a questionnaire with classifications sucha as: Great; Fair and Poor. In the evaluation of the internal auditors, the instruments were considered Great. After the implementation of the tool there was significant increase in the percentage of overall suitability and requirements, both in the evaluation of the internal external auditor. It was found that in the percentage of overall suitability, before the application of the tool, there was a statistically significant difference in the evaluation between the auditors, and this fact was not observed after the application of the tool. In the evaluation of the meals served, it was found that in the overall average, the requirements were considered Great. It is concluded that the quality tool was effective in adjusting the criteria for the hygienic sanitary control in Nutrition and Dietetics Hospital Services, according to the view of the internal and external auditors and helped in the understanding of the internal auditors, provided a more critical view of the requirements and decreased differences between evaluators. It is seen that the hygienic sanitary conditions of the hands and contact surfaces got better. After the improvement, the patients were satisfied with the meals served due to the implementation of the tool. / O objetivo foi elaborar uma ferramenta de qualidade para Serviços de Nutrição e Dietética Hospitalar e avaliar as condições higiênico-sanitárias desses locais, antes e após a implementação desta ferramenta, na visão do auditor interno e externo. Avaliar a satisfação dos auditores internos, quanto à ferramenta. Verificar as condições higiênico-sanitárias das mãos dos manipuladores e superfícies em contato com os alimentos, após melhorias e capacitação e avaliar a satisfação dos pacientes quanto às refeições servidas, após implementação da ferramenta. Esta pesquisa foi dividida em três estudos (1- elaboração e implementação da ferramenta; 2 avaliação das condições higiênico-sanitárias das mãos e superfícies de contato; 3 avaliação da satisação dos pacientes, quanto as refeições servidas). A amostra foi composta por 15 Serviços de Nutrição e Dietética Hospitalar. Para a elaboração da ferramenta de qualidade utilizou-se os requisitos das legislações e normas do Brasil. A ferramenta foi composta por quatro instrumentos de apoio, sendo divididos em Instrumento 1 Avaliação e planejamento da qualidade; Instrumento 2 Roteiro para elaboração do Manual de Boas Práticas; Instrumento 3 - Roteiro para elaboração dos Procedimentos Operacionais Padronizados e Instrumento 4 Roteiro para elaboração dos Controles Operacionais Essenciais. Após a elaboração da ferramenta, realizou-se a avaliação inicial dos requisitos higiênico-sanitários em cada local, através da aplicação do Instrumento 1, pelo auditor interno e externo. O responsável técnico do Serviço de Nutrição e Dietética Hospitalar foi considerado o auditor interno, e o auditor externo um profissional com experiência na área de alimentos, que avaliou todos locais. Após aplicação, os auditores internos receberam os resultados da avaliação do auditor externo e os demais instrumentos da ferramenta, sendo estipulado o prazo de um ano para sua implementação. No final do prazo, o auditor interno e externo aplicaram novamente o instrumento 1. Após, os auditores internos preencheram um questionário para avaliar sua satisfação quanto à ferramenta de qualidade. A avaliação das condições higiênico-sanitárias das mãos e superfícies em contato foi dividida em duas etapas. Primeiramente, realizou-se avaliação dos requisitos de higienização e análises microbiológicas nas mãos e superfície em contato. Após, os locais receberam os resultados e recomendações de adequação, sendo estipulados dois meses para adequar-se. Posteriormente, os locais que realizaram as melhorias, participaram da segunda etapa, sendo realizada capacitação e nova coleta das análises microbiológicas. Para avaliar a satisfação dos pacientes quanto às refeições servidas, elaborou-se um questionário, sendo classificadas como: Ótimo; Regular e Ruim. Na avaliação dos auditores internos, os instrumentos foram considerados Ótimos. Após a implementação da ferramenta houve um aumento significativo no percentual de adequação geral e dos requisitos, tanto na avaliação do auditor interno e externo. Verificou-se que no percentual de adequação geral, antes da aplicação da ferramenta, houve diferença estatisticamente significativa na avaliação entre os auditores, sendo esse fato não constatado, após a aplicação da ferramenta. Na avaliação das refeições servidas, constatou-se que na média geral, os requisitos foram considerados Ótimo. Conclui-se que a ferramenta de qualidade foi eficiente na adequação dos critérios para o controle higiênico-sanitário em Serviços de Nutrição e Dietética Hospitalar, na visão dos auditores interno e externo e auxiliou no conhecimento dos auditores internos, proporcionou uma visão mais crítica dos requisitos e diminuiu as divergências entre os avaliadores. Constata-se que as condições higiênico-sanitárias das mãos e superfície em contato, melhoraram após as melhorias da lista avaliação e capacitação e pacientes encontraram-se satisfeitos com as refeições servidas, após a implementação da ferramenta.
323

Desinfecção das canetas de alta rotação com álcool 70% p/v sem limpeza prévia: avaliação do risco de infecção cruzada / Disinfection of high-speed dental equipment with 70% ethanol without previous cleaning: assessment of cross-infection risk

Flávia Morais Gomes Pinto 17 June 2013 (has links)
Introdução: Na prática clínica odontológica, justificada pela praticidade, tempo curto disponível entre os atendimentos, associados à insuficiente previsão e provisão das Canetas de Alta Rotação (CAR), a descontaminação destas por meio de aplicação direta do álcool 70% p/v, sem limpeza prévia, é uma realidade. Este procedimento contraria, a priori, os protocolos de processamento que recomendam, no mínimo, limpeza seguida de desinfecção de alto nível para prevenção de infecção cruzada. Objetivo: avaliar a desinfecção das CAR com álcool 70% p/v, sem limpeza prévia com vistas ao risco de causar infecção cruzada. Método: caracterizou-se como uma pesquisa pragmática em um Estabelecimento Odontológico, onde rotineiramente as práticas de interesse para o estudo estavam presentes. O grupo experimental foi composto por 100 amostras de CAR utilizadas em tratamentos diversos, após a fricção do desinfetante por 90 segundos em sua superfície externa. Para avaliação dos resultados, uma gaze umedecida com soro fisiológico foi utilizada como carreador para o arraste dos possíveis micro-organismos nas superfícies desinfetadas. Metade do número das amostras (50) foi analisada pelo método de filtração por membrana (Método I - quantitativo), sendo cada gaze imersa em 300 mL de solução fisiológica. Sequencialmente, as amostras foram expostas a sonicação e agitação. Em seguida, o lavado foi filtrado em três partes iguais para diferentes análises (micro-organismos aeróbios, anaeróbios e específicos da microbiota oral humana), por meio da membrana com porosidade de 0,45 m. As outras 50 amostras foram analisadas pelo método de imersão direta da gaze em meio de cultura Fluid Thioglycollate Medium (Método II qualitativo). O tubo contendo a gaze foi agitado e incubado a 37ºC por 21 dias. Resultados: as amostras analisadas pelo Método I apresentaram crescimento positivo em 27/50 (54%) das amostras na faixa de 100 a 102 UFC/amostra. Deste total, foram identificados sete micro-organismos distintos, representados por 37,1% do Staphylococcus coagulase negativa, 28,5% dos Bacillus spp, 17,1% dos Bacilo Gram positivos não esporulados, 5,7% dos Micrococcus spp, 5,7% dos Penicillium spp, 2,8% Acinetobacter baumannii e 2,8% da Candida spp. No grupo analisado pelo Método II, o total de tubos com crescimento positivo foi de 12/50 (24%) amostras. Deste total, foram identificados três micro-organismos distintos, sendo 38,4% de Bacilos Gram positivos inespecíficos, seguidos dos Staphylococcus spp e Peptococcus spp com a mesma porcentagem de positividade de 30,7% cada. O grupo controle negativo, composto por amostras submetidas à limpeza e esterilização consecutiva, apresentaram resultados satisfatórios de ausência microbiana na totalidade das amostras. O crescimento médio encontrado no grupo controle positivo foi de 17,5 UFC/placa, com exceção de uma amostra que apresentou crescimento incontável. Conclusão: os resultados da presente investigação reprovam a prática da descontaminação das CAR com álcool 70% p/v, sem limpeza prévia, substanciada pela sobrevivência de micro-organismos que não corresponderam à ação fungicida e bactericida esperada do álcool 70% p/v na condição de desinfetante de nível intermediário. Outro aspecto que reforça a reprovação da prática analisada é a consideração de que os micro-organismos recuperados, mesmo sendo de baixo potencial patogênico, podem comportar-se como anfibiontes, isto é, são capazes de agredir o hospedeiro quando as condições ambientais e imunológicas são favoráveis aos micro-organismos, causando infecção. / Introduction: In dental clinical practice, decontamination of high-speed dental equipment (HSDE) by direct use of 70% ethanol without previous cleaning, justified by practicality, the short-time available between appointments, together with inadequate predicting and provision of HSDE, is a reality. This procedure, a priori, contradicts the processing protocols recommended to prevent cross-infection. Objective: to evaluate the disinfection of HSDE with 70% ethanol without previous cleaning, with views of cross-infection risk. Method: the present study was characterized as a pragmatic research in a Dental Office, which practices of interest to the study were routinely performed. The experimental group consisted of 100 samples of HSDE used in different treatments after rubbing the disinfectant for 90 seconds on its outer surface. To evaluate the results, gauze moistened with saline solution was used as a carrier for obtaining microorganisms from the disinfected surfaces. Half of the samples (50) were analyzed by membrane filtration (Method I - quantitative), with the gauze being immersed in 300 mL of saline solution. Sequentially, the sample was exposed to sonication and agitation. After that, the lavage was filtered in three equal parts for different analyses, through a membrane with 0.45 m porosity and seeded on blood agar culture medium, for recovery of aerobic and anaerobic microorganisms, as well as those specifically found in the human oral microbiota. The other 50 samples were analyzed by direct immersion of the gauze in culture medium (Method II - Qualitative): after rubbing the wet gauze on the outer surface of the HSDE, it was placed directly in Fluid Thioglycollate culture medium. The tube containing the gauze was shaken in a vortex mixer and then incubated at 37 ° C for 21 days. Results: samples analyzed by Method I, showed positive growth in 27/50 (54%) of the samples within the range of 100 to 102 CFU/sample. Of this total, 7 different microorganisms were identified, represented by 37.1% of coagulase-negative Staphylococcus, 28.5% of Bacillus spp, 17.1% of non-sporulating Gram-positive bacillus, 5.7% of Micrococcus spp, 5.7 % of Penicillium spp, 2.8% of Acinetobacter baumannii and 2.8% of Candida spp. In the group analyzed by Method II, the total number of tubes with positive growth was 12/50 (24%) samples. Of this total, we identified 2 different microorganisms, being 38.4% of Gram-positive bacillus nonspecific, followed by Staphylococcus spp and Peptococcus spp with the same percentage of positivity of 30.7% each. The negative control group, composed of samples subjected to cleaning and sterilization consecutive showed satisfactory results. The average growth found in the positive control group was 17.5 CFU/sample, except for one sample that showed growth uncountable. Conclusion: the results of the present study do not support the practice of decontamination of HSDE with 70% ethanol without previous cleaning, based on the evidence of microorganism survival that did not meet the expected bactericidal and fungicidal action of alcohol as an intermediate level disinfectant. Another aspect that reinforces the disapproval this practice, it is the consideration that the micro-organisms recovered, even being low pathogenic potential, may behave as anfibionte, which are capable of harming the host when the environmental and immune conditions are favorable to micro-organisms, causing infection.
324

Avaliação da viabilidade de cistos de Giardia spp. e oocistos de Cryptosporidium parvum em água filtrada obtida após tratamento convencional com flotação e ozonização / Viability assessment of Giardia spp. cysts and Cryptosporidium parvum oocysts in filtered water obtained after conventional treatment with flotation and ozonation

Dayane Mendes Boni 09 September 2016 (has links)
Esta pesquisa avaliou o uso de ozônio para inativar cistos de Giardia spp. e oocistos de Cryptosporidium parvum presentes na água filtrada obtida após a utilização da tecnologia de ciclo completo com flotação (coagulação, floculação, flotação e filtração) em escala de bancada, empregando o cloreto de polialumínio – PAC – como coagulante. O método de floculação em carbonato de cálcio – FCCa, sem e com a etapa de separação imunomagnética – IMS – foi utilizado na quantificação dos protozoários. A recuperação nos ensaios de qualidade utilizando o kit Easyseed® de Giardia spp. foi de 8,4% ± 97,4% sem IMS e com IMS, com duas dissociações, o valor foi de 7,4% ± 39,7% e, com três dissociações, a recuperação alcançou 9,6% ± 34,7%, portanto, somente o ensaio com IMS e duas dissociações, não atendeu os padrões do Método 1623.1. A recuperação de Cryptosporidium parvum, obteve valor de 3,4% ± 100% em ensaio sem IMS e com IMS, o valor obtido foi de 1,0% ± 70,0% com duas dissociações e 1,8% ± 44,4% com três dissociações e nos três métodos apresentados, não houve conformidade com os critérios do Método 1623.1. Na etapa de desinfecção com ozônio, os ensaios realizados na Etapa 1, que se utilizou 5 mgO3L-1 e tempo de contato de 1 min sem IMS, as maiores inativações atingidas foram de 2,52 e 2,22 log para cistos de Giardia spp. e oocistos de Cryptosporidium parvum, respectivamente. Com o tempo de contato de 5 min, as maiores inativações foram de 2,52 e 2,92 log de cistos de Giardia spp. e oocistos de Cryptosporidium parvum, respectivamente. Na Etapa 2, com IMS, utilizando a mesma dosagem e tempo de contato de 1 min, obteve-se 2,27 e 0,21 log de inativação para cistos e oocistos, respectivamente. Comparando-se com o tempo de contato de 5 min, foram obtidos 2,9 e 2,3 log de inativação para cistos e oocistos, respectivamente. Na avaliação de custo, o método de FCCa sem IMS demonstrou ser o mais econômico em relação ao procedimento com IMS. A influência da inclusão da terceira dissociação ácida no método com IMS também foi analisada e este procedimento não resultou em diferenças estatísticas significativas nos resultados. / This research evaluated the use of ozone to inactivate Giardia spp. cysts and Cryptosporidium parvum oocysts present in the filtered water obtained after the use of the complete cycle of flotation technology (coagulation, flocculation, flotation and filtration) on a bench scale employing polyaluminium chloride - PAC as coagulant. The calcium carbonate flocculation method - FCCa, without and with immunomagnetic separation step - IMS has been used in the quantification of protozoa. The recovery in quality test using the kit Easyseed® for Giardia spp. was 8.4% ± 97.4% non-IMS and IMS with two dissociations, the value was 7.4% ±39.7% and with three dissociations, the recovery reached 9.6% ± 34,7%, so only the test with IMS and two dissociations, did not meet the standards of method 1623.1. Recovery of Cryptosporidium parvum obtained value of 3.4% ± 100% in non-IMS and IMS testing, the value obtained was 1.0% ± 70.0% with two dissociations and 1.8% ± 44.4% with three dissociations and the three methods presented, there was non-compliance with the criteria of Method 1623.1. In step disinfection with ozone, tests performed in Step 1 was used 5 mgO3L-1 and contact time of 1 min without IMS, the major inactivation achieved were 2.52 and 2.22 log for Giardia spp. cysts and Cryptosporidium parvum oocysts, respectively. With 5 minutes of contact time, the greater inactivation were 2.52 and 2.92 log for Giardia spp. cysts and Cryptosporidium parvum oocysts, respectively. In Step 2, with IMS, using the same dose and 1 min contact time, there was obtained 2.27 and 0.21 log inactivation for cysts and oocysts, respectively. Compared with the 5 min of contact time, were obtained 2.9 and 2.3 log inactivation for cysts and oocysts, respectively. In evaluating cost, the FCCa method without IMS proved to be the most economical in relation to the procedure with IMS. The influence of inclusion of the third acid dissociation method in IMS was also analyzed and this procedure did not result in statistically significant differences in the results.
325

Inativação de indicadores patogênicos em sistemas combinados de tratamento e pré-desinfecção de esgoto sanitário / Inactivation of pathogens tracers in combined systems for sanitary sewer treatment and pre-disinfection

Patrícia Bilotta Monaco 07 April 2006 (has links)
A proposta apresentada se baseia na introdução de um estágio intermediário de desinfecção previamento ao tratamento biológico visando intensificar os efeitos do estágio seguinte destinado à desinfecção convencional. Para estudo de caso foram aplicadas as técnicas de ozonização e radiação UV combinadas em instalações piloto que simulam duas condições seqüenciais de desinfecção. O desempenho do método proposto foi avaliado através de exames microbiológicos de amostras do efluente anaeróbio previa e posteriormente à desinfecção, utilizando indicadores de contaminação por bactérias (Escherichia coli e coliformes totais), vírus (colifagos) e protozoário (Clostridium perfringens). Os resultados obtidos no sistema combinado pré-desinfecção/desinfecção revelaram eficiência de inativação superior quando comparada ao procedimento convencional. Nas análises de E.coli, por exemplo, a aplicação de apenas 1 mg de ozônio/L ou 51 mW de radiação/'CM POT.2', na primeira etapa de desinfecção, foi suficiente para se alcançar 1 log acima do valor correspondente ao método convencional. Mesmo indicadores mais resistentes como C. perfringens apresentaram redução da fração N/No da ordem de 1 log em relação ao método proposto. Além disso, estes níveis de inativação foram alcançados mesmo sob a influência de elevada concentração de SST, SSV e DQO na entrada na unidade piloto destinada à pré-desinfecção. Entre as seqüências de experimentação investigadas ('O IND.3'/'O IND.3', 'O IND.3'/UV, UV/'O IND.3' e UV/UV) não foram observadas grandes variações. De modo semelhante, os resultados revelaram que a relação N/No, para os indivíduos submetidos ao sistema combinado, não foi afetada pelo aumento no tempo de exposição ao agente inativante ('O IND.3': 5, 7, 10 min; UV: 30, 60, 120s). Considerando as baixas dosagens de 'O IND.3' e UV aplicadas na primeira etapa, somada às condições limitadas de desempenho do sistema real examinado, os níveis de inativação alcançados sugerem grande potencialidade de utilização do método alternativo proposto, comprovando sua viabilidade técnica / The present proposition is based on the introduction of an intermediate disinfection stage before the biological treatment, in order to intensify the effects of the next stage employed in conventional disinfection. Studies were performed using combined ozonization and UV radiation techniques, in a model installation that simulates two sequential disinfection conditions. The performance of the method was evaluated using microbiological exams of samples taken from the anaerobic effluent before and after the disinfection. Bacterial (Escherichia coli and total coliforms), viral (coliphages) and protozoan (Clostridium perfringens contamination tracers were used in such exams. Results obtained by combining pre-disinfection and disinfection reveal superior inactivation efficiency as compared to the conventional procedure. For example, in the E. coli analysis the application of only 1 mg of ozone/L or 51 mW/'CM POT.2' of radiation in the first disinfection stage was enough for achieving 1 log above the convention method. Even more resistant tracers, such as C. perfringens, showed aproximatelly 1 log of reduction in the N/No fraction in the proposed method. Besides, these inactivation levels were achieved even for high concentrations of SST, SSV and DQO in the entrance of the pre-disinfection unit. No significant variations were observed among the disinfection sequences ('O IND.3'/'O IND.3','O IND.3'/UV,UV/'O IND.3', and UV/UV). Similarly, the results showed that the N/No relation, for individuals submitted to the combined system, was not affected by the increase of the exposition time to the inactivation agent ('O IND.3': 5, 7, 10 min; UV: 30, 60, 120 s). Taking into account the low dosages of 'O IND.3' and UV applied in the first stage and the limited performance conditions of the real system, the achieved inactivation levels suggest a great potential for the alternative method proposed, demonstrating its technical viability
326

Protocolo de verificação do processo de esterilização por vapor de formaldeído / Verification protocol of the formaldehyde steam sterilization process

Borini, Júlio Cesar 08 December 2016 (has links)
Este trabalho apresenta o estudo do processo de esterilização de materiais e instrumentais cirúrgicos em autoclaves que se utilizam do agente esterilizante, o vapor à baixa temperatura de formaldeído. Processo esse utilizado para materiais termosensiveis, ou seja, que não suportam temperaturas superiores a 80°C. Assim objetivo desse trabalho, foi avaliar essa tecnologia de esterilização a baixa temperatura, que já é utilizada há mais de 20 anos em vários países, inclusive aqui no Brasil, porém com pouco detalhes de estudos conclusivos sobre o assunto na literatura nacional e internacional. Este estudo foi baseado nas Normas ABNT NBR 15659 e NF EN ISO 25424 que tratam especificamente dos requisitos, métodos e cuidados na esterilização de vapor a baixa temperatura e formaldeído, implementando um protocolo de verificação para estudo da tecnologia. Para tanto foi elaborada uma metodologia de avaliação, da instalação de esterilizadores que utilizam como agente esterilizante o formaldeído. Na verificação da eficácia da metodologia 3 tipos de equipamentos de esterilização foram testados. Os equipamentos testados são de fabricação brasileira (02 deles) e um de fabricação sueca. Os testes foram feitos em 6 hospitais, onde foram avaliados desde a sua instalação, avaliação dos parâmetros de tempo, temperatura e pressão (com equipamentos calibrados e rastreados pelo INMETRO), avaliação do nível de resíduos no material (com laudos feitos por laboratórios credenciados), uso de indicadores de processo (biológicos e químicos), avaliação ambiental (ar e saída do dejeto para o esgoto), controles de manutenções preventivas e segurança do operador (EPI). Todos os ciclos avaliados apresentaram resultados dentro dos parâmetros mínimos sugerido na Norma ABNT NBR 15659 e NF EN ISO 25424. Concluindo que se seguindo rigorosamente o que pede a Norma e os manuais dos fabricantes dos equipamentos, pode-se perfeitamente obter um processo seguro de esterilização para o Hospital, e atender todos os níveis de segurança tanto para o operador como para o paciente que irá usar o material processado no ciclo de esterilização. / This work presents the study of the sterilization process of surgical materials and instruments in autoclaves using the sterilizing agent, the low temperature vapor of formaldehyde. This process is used for thermosensitive materials, is they do not withstand temperatures above 80 ° C. The objective of this study was to evaluate the low temperature sterilization technology, which has been used for more than 20 years in several countries, including here in Brazil, but with little details of conclusive studies on the subject in the national and international literature. This study was based on the ABNT NBR 15659 and NF EN ISO 25424 standards that specifically deal with the requirements, methods and care in low temperature steam sterilization and formaldehyde, implementing a verification protocol for technology study. For this, an evaluation methodology was elaborated for the installation of sterilizers that use formaldehyde as the sterilizing agent. In the verification of the effectiveness of the methodology 3 types of sterilization equipment were tested. The equipment tested is of Brazilian manufacture (02 of them) and one of Swedish manufacture. The tests were carried out in 6 hospitals, where they were evaluated since its installation, evaluation of parameters of time, temperature and pressure (with equipment calibrated and tracked by INMETRO), evaluation of the level of residues in the material (with reports made by accredited laboratories), use of process indicators (biological and chemical), environmental assessment (air and exits to the sewage), preventive maintenance controls and operator safety (EPI). All the evaluated cycles presented results within the minimum parameters suggested in the Standard ABNT NBR 15659 and NF EN ISO 25424. Concluding that strictly following the norms and the manuals of the equipment manufacturers, it is perfectly possible to obtain a safe process of sterilization To the Hospital, and meet all levels of safety for both the operator and the patient who will use the material processed in the sterilization cycle.
327

Protocolo de verificação do processo de esterilização por vapor de formaldeído / Verification protocol of the formaldehyde steam sterilization process

Borini, Júlio Cesar 08 December 2016 (has links)
Este trabalho apresenta o estudo do processo de esterilização de materiais e instrumentais cirúrgicos em autoclaves que se utilizam do agente esterilizante, o vapor à baixa temperatura de formaldeído. Processo esse utilizado para materiais termosensiveis, ou seja, que não suportam temperaturas superiores a 80°C. Assim objetivo desse trabalho, foi avaliar essa tecnologia de esterilização a baixa temperatura, que já é utilizada há mais de 20 anos em vários países, inclusive aqui no Brasil, porém com pouco detalhes de estudos conclusivos sobre o assunto na literatura nacional e internacional. Este estudo foi baseado nas Normas ABNT NBR 15659 e NF EN ISO 25424 que tratam especificamente dos requisitos, métodos e cuidados na esterilização de vapor a baixa temperatura e formaldeído, implementando um protocolo de verificação para estudo da tecnologia. Para tanto foi elaborada uma metodologia de avaliação, da instalação de esterilizadores que utilizam como agente esterilizante o formaldeído. Na verificação da eficácia da metodologia 3 tipos de equipamentos de esterilização foram testados. Os equipamentos testados são de fabricação brasileira (02 deles) e um de fabricação sueca. Os testes foram feitos em 6 hospitais, onde foram avaliados desde a sua instalação, avaliação dos parâmetros de tempo, temperatura e pressão (com equipamentos calibrados e rastreados pelo INMETRO), avaliação do nível de resíduos no material (com laudos feitos por laboratórios credenciados), uso de indicadores de processo (biológicos e químicos), avaliação ambiental (ar e saída do dejeto para o esgoto), controles de manutenções preventivas e segurança do operador (EPI). Todos os ciclos avaliados apresentaram resultados dentro dos parâmetros mínimos sugerido na Norma ABNT NBR 15659 e NF EN ISO 25424. Concluindo que se seguindo rigorosamente o que pede a Norma e os manuais dos fabricantes dos equipamentos, pode-se perfeitamente obter um processo seguro de esterilização para o Hospital, e atender todos os níveis de segurança tanto para o operador como para o paciente que irá usar o material processado no ciclo de esterilização. / This work presents the study of the sterilization process of surgical materials and instruments in autoclaves using the sterilizing agent, the low temperature vapor of formaldehyde. This process is used for thermosensitive materials, is they do not withstand temperatures above 80 ° C. The objective of this study was to evaluate the low temperature sterilization technology, which has been used for more than 20 years in several countries, including here in Brazil, but with little details of conclusive studies on the subject in the national and international literature. This study was based on the ABNT NBR 15659 and NF EN ISO 25424 standards that specifically deal with the requirements, methods and care in low temperature steam sterilization and formaldehyde, implementing a verification protocol for technology study. For this, an evaluation methodology was elaborated for the installation of sterilizers that use formaldehyde as the sterilizing agent. In the verification of the effectiveness of the methodology 3 types of sterilization equipment were tested. The equipment tested is of Brazilian manufacture (02 of them) and one of Swedish manufacture. The tests were carried out in 6 hospitals, where they were evaluated since its installation, evaluation of parameters of time, temperature and pressure (with equipment calibrated and tracked by INMETRO), evaluation of the level of residues in the material (with reports made by accredited laboratories), use of process indicators (biological and chemical), environmental assessment (air and exits to the sewage), preventive maintenance controls and operator safety (EPI). All the evaluated cycles presented results within the minimum parameters suggested in the Standard ABNT NBR 15659 and NF EN ISO 25424. Concluding that strictly following the norms and the manuals of the equipment manufacturers, it is perfectly possible to obtain a safe process of sterilization To the Hospital, and meet all levels of safety for both the operator and the patient who will use the material processed in the sterilization cycle.

Page generated in 0.0965 seconds