• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 321
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 327
  • 199
  • 61
  • 42
  • 41
  • 40
  • 39
  • 34
  • 30
  • 29
  • 28
  • 28
  • 26
  • 26
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
301

Estudo do crescimento bacteriano e da aplicação de procedimentos de limpeza e desinfecção no aço inoxidável 304L / Study of bacterial growth and the application of procedures for cleaning and disinfecting in stainless steel 304L

Yohandrina Ulloa Payares 27 April 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Técnicas de limpeza química ou mecânica são comumente empregadas para evitar a formação de biofilmes e problemas associados com a colonização de superfícies por micro-organismos. Neste trabalho, amostras de aço inox 304L foram submetidas a ensaios acelerados de crescimento de biofilme, o qual foi posteriormente removido por tratamentos de limpeza e desinfecção (choque térmico com água a 70C por 1h, limpeza com ácido fosfórico 20 % v/v por 30min e desinfecção com peróxido de hidrogênio 0,17 % v/v por 1h). Com o objetivo de verificar a influência destes tratamentos na remoção do biofilme, este foi caracterizado (por quantificação microbiana e análises de espectroscopia de impedância eletroquímica - EIE), antes e após a aplicação dos tratamentos. Dois casos foram estudados. No primeiro caso, simularam-se condições presentes em tubulações de ambientes hospitalares e sistemas de distribuição de água quente. O micro-organismo utilizado foi a bactéria Serratia marcences. O processo de formação de biofilme e posterior limpeza e desinfecção foi realizado de modo contínuo durante 15 semanas. Os resultados de quantificação microbiana e de EIE mostraram que desde a primeira semana de exposição e ao longo dos ensaios, formou-se um biofilme aderente à superfície do aço e que o emprego dos tratamentos de limpeza e desinfecção não foi eficaz na remoção do biofilme. Em um segundo caso, simularam-se condições presentes em tubulações da indústria de água mineral, empregando-se a bactéria Pseudomonas aeruginosa. Neste caso, as técnicas de limpeza e desinfecção foram aplicadas individualmente e em conjunto. A aplicação de choque térmico, assim como da limpeza ácida, sobre um biofilme com 72 h de formação foi capaz de eliminar as bactérias viáveis, presentes na superfície do aço. Entretanto, a desinfecção com peróxido de hidrogênio não foi capaz de eliminá-las. Nas duas condições, porém, as análises de EIE do sistema aço/biofilme mostraram que o mesmo não foi completamente removido da superfície do metal. Correlacionando os dois casos, pode-se inferir que a superfície do aço inox 304L é rapidamente colonizada pelas duas espécies microbianas e que as técnicas de limpeza e desinfecção são capazes de reduzir e até eliminar as células viáveis, embora não removam completamente o biofilme da superfície. Por outro lado, é importante ressaltar que fatores como a arquitetura, espessura e porosidade do biofilme, e propriedades intrínsecas da superfície, são fatores que afetam os valores de impedância medidos, sendo necessário considerá-los na análise, tanto da formação do biofilme, quanto dos efeitos dos procedimentos de limpeza e desinfecção / Techniques for chemical or mechanical cleaning are usually employed to prevent the formation of biofilm and the problems associated with the colonization of surfaces by micro-organisms. In this work, samples of 304 L stainless steel were submitted to experiments of accelerated growth of biofilm, which was subsequently removed by cleaning and disinfection treatment (heat shock with water at 70 C for 1h, cleaning with phosphoric acid 20% v/v for 30 min and disinfection with hydrogen peroxide 0,17% v/v for 1h). In order to verify the influence of these treatments on biofilm removal, analyses of microbial quantification and electrochemical impedance spectroscopy (EIS), before and after the treatments were employed. Two cases were studied. In the first case, it was simulated the conditions found in piping for hospital environment and systems for the distribution of hot water. The micro-organism used was the bacteria Serratia marcences. The process of biofilm formation and subsequent cleaning and disinfection was performed continuously for 15 weeks. The results of measurement of microbial and EIS showed that since the first week of exposure and during the testing, an adherent biofilm was formed on the steel surface and that the use of cleaning and disinfecting treatments were not effective in removing biofilm. In a second case, it was simulated the conditions present in the pipes of the mineral water industry, using the bacterium Pseudomonas aeruginosa. In this case, the cleaning and disinfection techniques were applied individually and as a whole. The application of heat shock, as well as acid cleaning, to the biofilm formated after 72 h was able to eliminate the viable bacteria present in the steel surface. However, disinfection with hydrogen peroxide was not able to eliminate them. In both conditions, however, the EIS analysis of the steel/biofilm system showed that it was not satisfactorily removed from the metal surface. Comparing the two cases, it can be inferred that the surface of 304L stainless steel is rapidly colonized by the two microbial species studied and that the cleaning and disinfection techniques are able to reduce and even eliminate viable cells, although they could not completely remove the biofilm from the surface. On the other hand, it is important to note that factors such as properties of the electrode surface (roughness, porosity and adsorption), the electrode potential, and the architecture, thickness and porosity of the biofilm, are factors that affect the measured impedance values, it is necessary to consider them in the analysis of biofilm formation and effects of cleaning and disinfection
302

Estudo do crescimento bacteriano e da aplicação de procedimentos de limpeza e desinfecção no aço inoxidável 304L / Study of bacterial growth and the application of procedures for cleaning and disinfecting in stainless steel 304L

Yohandrina Ulloa Payares 27 April 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Técnicas de limpeza química ou mecânica são comumente empregadas para evitar a formação de biofilmes e problemas associados com a colonização de superfícies por micro-organismos. Neste trabalho, amostras de aço inox 304L foram submetidas a ensaios acelerados de crescimento de biofilme, o qual foi posteriormente removido por tratamentos de limpeza e desinfecção (choque térmico com água a 70C por 1h, limpeza com ácido fosfórico 20 % v/v por 30min e desinfecção com peróxido de hidrogênio 0,17 % v/v por 1h). Com o objetivo de verificar a influência destes tratamentos na remoção do biofilme, este foi caracterizado (por quantificação microbiana e análises de espectroscopia de impedância eletroquímica - EIE), antes e após a aplicação dos tratamentos. Dois casos foram estudados. No primeiro caso, simularam-se condições presentes em tubulações de ambientes hospitalares e sistemas de distribuição de água quente. O micro-organismo utilizado foi a bactéria Serratia marcences. O processo de formação de biofilme e posterior limpeza e desinfecção foi realizado de modo contínuo durante 15 semanas. Os resultados de quantificação microbiana e de EIE mostraram que desde a primeira semana de exposição e ao longo dos ensaios, formou-se um biofilme aderente à superfície do aço e que o emprego dos tratamentos de limpeza e desinfecção não foi eficaz na remoção do biofilme. Em um segundo caso, simularam-se condições presentes em tubulações da indústria de água mineral, empregando-se a bactéria Pseudomonas aeruginosa. Neste caso, as técnicas de limpeza e desinfecção foram aplicadas individualmente e em conjunto. A aplicação de choque térmico, assim como da limpeza ácida, sobre um biofilme com 72 h de formação foi capaz de eliminar as bactérias viáveis, presentes na superfície do aço. Entretanto, a desinfecção com peróxido de hidrogênio não foi capaz de eliminá-las. Nas duas condições, porém, as análises de EIE do sistema aço/biofilme mostraram que o mesmo não foi completamente removido da superfície do metal. Correlacionando os dois casos, pode-se inferir que a superfície do aço inox 304L é rapidamente colonizada pelas duas espécies microbianas e que as técnicas de limpeza e desinfecção são capazes de reduzir e até eliminar as células viáveis, embora não removam completamente o biofilme da superfície. Por outro lado, é importante ressaltar que fatores como a arquitetura, espessura e porosidade do biofilme, e propriedades intrínsecas da superfície, são fatores que afetam os valores de impedância medidos, sendo necessário considerá-los na análise, tanto da formação do biofilme, quanto dos efeitos dos procedimentos de limpeza e desinfecção / Techniques for chemical or mechanical cleaning are usually employed to prevent the formation of biofilm and the problems associated with the colonization of surfaces by micro-organisms. In this work, samples of 304 L stainless steel were submitted to experiments of accelerated growth of biofilm, which was subsequently removed by cleaning and disinfection treatment (heat shock with water at 70 C for 1h, cleaning with phosphoric acid 20% v/v for 30 min and disinfection with hydrogen peroxide 0,17% v/v for 1h). In order to verify the influence of these treatments on biofilm removal, analyses of microbial quantification and electrochemical impedance spectroscopy (EIS), before and after the treatments were employed. Two cases were studied. In the first case, it was simulated the conditions found in piping for hospital environment and systems for the distribution of hot water. The micro-organism used was the bacteria Serratia marcences. The process of biofilm formation and subsequent cleaning and disinfection was performed continuously for 15 weeks. The results of measurement of microbial and EIS showed that since the first week of exposure and during the testing, an adherent biofilm was formed on the steel surface and that the use of cleaning and disinfecting treatments were not effective in removing biofilm. In a second case, it was simulated the conditions present in the pipes of the mineral water industry, using the bacterium Pseudomonas aeruginosa. In this case, the cleaning and disinfection techniques were applied individually and as a whole. The application of heat shock, as well as acid cleaning, to the biofilm formated after 72 h was able to eliminate the viable bacteria present in the steel surface. However, disinfection with hydrogen peroxide was not able to eliminate them. In both conditions, however, the EIS analysis of the steel/biofilm system showed that it was not satisfactorily removed from the metal surface. Comparing the two cases, it can be inferred that the surface of 304L stainless steel is rapidly colonized by the two microbial species studied and that the cleaning and disinfection techniques are able to reduce and even eliminate viable cells, although they could not completely remove the biofilm from the surface. On the other hand, it is important to note that factors such as properties of the electrode surface (roughness, porosity and adsorption), the electrode potential, and the architecture, thickness and porosity of the biofilm, are factors that affect the measured impedance values, it is necessary to consider them in the analysis of biofilm formation and effects of cleaning and disinfection
303

Influência da adição de tensoativos nas propriedades dos hipocloritos de sódio e cálcio / Influence of surfactants addition on the properties of sodium and calcium hypochlorite

Iglesias, Julia Eick January 2016 (has links)
O objetivo do presente estudo foi o de avaliar a influência da associação dos tensoativos cetrimida 0,2%, cetrimida 0,1% e cloreto de benzalcônio 0,008% aos hipocloritos de sódio e de cálcio 2,5% nas propriedades de pH, quantidade de cloro livre, tensão superficial, ângulo de contato, dissolução pulpar e atividade antimicrobiana. O pH e a concentração de cloro ativo foram avaliados por pHmetro digital e pela titulação, respectivamente. A tensão superficial foi mensurada através da técnica do anel de platina com um tensiômetro de Du Noüy. O ângulo de contato das soluções em bases de dentina humana foi aferido pelo software Drop Shape Analyzer. Para a análise da dissolução pulpar foram utilizados fragmentos de polpas bovinas e os resultados foram expressos por percentual de perda de massa. A atividade antimicrobiana frente ao Enterococcus faecalis foi realizada pelo método de difusão em Ágar. Os resultados mostraram que a associação de tensoativos aos hipocloritos de sódio e cálcio não alterou as propriedades de pH, cloro livre e dissolução pulpar das soluções. O hipoclorito de cálcio apresentou o maior valor de tensão superficial (72,13 ± 1,82 mN/m). Quando associados aos tensoativos, os hipocloritos de sódio e cálcio tiveram uma redução significativa da tensão superficial. O mesmo foi observado para o ângulo de contato. Os tensoativos apresentam atividade antimicrobiana. A associação dos hipocloritos à cetrimida 0,2% ou 0,1% aumentou o halo de inibição frente ao Enterococcus faecalis. Concluiu-se que a associação de tensoativos não modificaram as propriedades de pH, cloro livre e dissolução pulpar dos hipocloritos de sódio e cálcio 2,5%. Porém, ela foi capaz de diminuir a tensão superficial e o ângulo de contato das soluções. Ainda, a associação da cetrimida 0,2% e 0,1% melhorou a capacidade antimicrobiana dos hipocloritos. / The aim of this study was to evaluate the influence of surfactants 0,2% or 0,1% cetrimide or 0,008% benzalkonium chloride on 2.5% sodium and calcium hypochlorite in the properties of pH, free chlorine content, surface tension, contact angle, pulp dissolution and antimicrobial activity. The pH and free chlorine content were evaluated by digital pHmeter and by titration, respectively. Surface tension was measured by the platinum ring technique with a Du Noüy tensiometer. Solution’s contact angle in human dentin surfaces was checked by Drop Shape Analyzer software. Bovine pulps were used for pulp dissolution analysis and the dissolving capacity was expressed by percentual weight loss. Antimicrobial activity over Enterococcus faecalis was evaluated through the ágar diffusion method. The surfactants association on sodium and calcium hypochlorites did not alter pH, free chlorine content and pulp dissolution properties. Calcium hypochlorite had the higher surface tension (72,13 ± 1,82 mN/m). However, when sodium and calcium hypochlorite were associated to surfactants, a significant reduction of surface tension occured. The same was observed for contact angle analysis. The surfactants used in this study have antimicrobial activity. The association of 0,2% or 0,1% cetrimide enhanced antimicrobial activity of both hypochlorites. It was possible to conclude that surfactants association did not alter pH, free chlorine content and pulp dissolution properties of 2,5% sodium and calcium hypochlorite. It was capable to reduce surface tension and contact angle of the solutions. Moreover, the 0,2% or 0,1% cetrimide association increased antimicrobial activity of hypochlorite.
304

Tratamento terciario de esgoto sanitario para fins de reuso urbano / Tertiary wastewater treatment for urban reuse

Tosetto, Mariana de Salles 31 August 2005 (has links)
Orientadores: Ricardo de Lima Isaac, Regina Maura Bueno Franco / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-05T11:45:48Z (GMT). No. of bitstreams: 1 Tosetto_MarianadeSalles_M.pdf: 2211562 bytes, checksum: 608a86bf4dcf009813ef868c3b96d5c6 (MD5) Previous issue date: 2005 / Resumo: Este trabalho consistiu na análise da eficiência do tratamento terciário do efluente da Estação de Tratamento de Esgoto (ETE) Samambaia, no município de Campinas-SP, para fins de reuso em ambiente urbano. O sistema avaliado era composto das etapas de coagulação, pré-floculação em meio granular, filtração e desinfecção com radiação ultravioleta. O estudo experimental foi realizado em escala de bancada para otimização do processo de coagulação, e em escala piloto para avaliar as etapas de pré-floculação, filtração e desinfecção. Foram investigados, como coagulantes químicos, o sulfato férrico e o sulfato de alumínio, taxas de filtração de 120 e 300 m3/m2.dia, e dose de radiação UV de, aproximadamente, 95 mWs/cm2. O efluente terciário produzido na instalação piloto não foi considerado seguro sob o aspecto de saúde pública para aplicação em reuso urbano, como irrigação de parques e jardins, limpeza urbana, lavagem de veículos, combate a incêndio, entre outros, pois não atendeu as recomendações da Organização Mundial de Saúde ¿ OMS quanto à concentração de ovos de helmintos, e apresentou cistos de Giardia spp. ainda em concentrações elevadas, embora nenhuma das recomendações encontradas na literatura contemple limites para estes últimos. Os parâmetros turbidez, DBO, sólidos em suspensão, Coliformes Totais e E. coli atenderam as metas e padrões recomendados na literatura para reuso urbano / Abstract: This work consisted of efficiency analysis of tertiary treatment of effluent from a Wastewater Treatment Plant (WWTP Samambaia) that is located at the city of Campinas (São Paulo State, Brazil), for urban reuse. The system consisted of a physico-chemical treatment composed of coagulation, granular upflow flocculation, direct downflow filtration and ultraviolet disinfection. The experimental work was carried out using bench-scale tests to optimize chemical coagulation, and in a pilot installation to evaluate the flocculation, filtration and disinfection steps. Aluminum sulfate and ferric sulfate were evaluated as coagulants. Filtration rates of 120 and 300 m/day and UV doses of 95 mWs/cm2 were applied. The tertiary effluent obtained at the pilot plant was not considered safe, under the public health point of view, for urban reuse, like gardens and parks irrigation, urban cleaning, car-washing, fire protection and others, because the helminth eggs concentration, that did not comply to World Health Organization-WHO recommendation, and the high level of Giardia spp. cysts concentration detected at the tertiary-treated effluent, although the quality requirements for urban reuse do not limit this concentration. The turbidity, BOD, suspended solids and coliforms parameters were according to literature recommendation for urban reuse / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
305

Avaliação clínica comparativa entre a técnica de tratamento periodontal convencional e a desinfecção total de boca / Comparative clinical evaluation between the conventional periodontal treatment and the full mouth disinfection

Pontillo, Viviane 09 February 2017 (has links)
Submitted by Edineia Teixeira (edineia.teixeira@unioeste.br) on 2018-02-27T18:43:44Z No. of bitstreams: 2 Viviane_ Pontillo2017.pdf: 883660 bytes, checksum: 22b030cf34d5c5d47e0e77a204bc8832 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-02-27T18:43:44Z (GMT). No. of bitstreams: 2 Viviane_ Pontillo2017.pdf: 883660 bytes, checksum: 22b030cf34d5c5d47e0e77a204bc8832 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-02-09 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Periodontal disease is chronic and multifactorial, affecting protection and support tissues of the tooth. Its onset is due to the accumulation of bacterial plaque, in which are found microorganisms, mainly Gram-negative, which stimulate the host cells and the production of immunoinflammatory molecules. Thus, the objective of this research was to evaluate the effectiveness of the two techniques of periodontal treatment through clinical parameters and laboratory tests. For this, 42 patients were randomly evaluated and divided into three groups of 14 patients each: Group 1 (control) - periodontally healthy patients, with the other groups of patients with moderate to severe chronic periodontitis, group 2 being treated with the conventional periodontal treatment technique and group 3 with the total mouth disinfection technique. All of these patients were submitted to periodontal treatment and evaluated through plaque and gingival index, depth of probing, clinical insertion level, bleeding probing, analysis of PGE2 isoform expression and analysis of crevicular gingival fluid, being evaluated for a total period of 180 days. The results of the periodontal and laboratory parameters did not show significant difference statistically (p> 0.05) when compared to the techniques in the period of 180 days. Therefore, it can be affirmed that both periodontal treatments were effective, but without superiority between them. However, both improved periodontal and laboratorial clinical parameters significantly. Thus, the professional should evaluate the case of the patient and choose the treatment that best suits its needs and availability. / A doença periodontal é crônica e multifatorial, afetando os tecidos de proteção e sustentação do dente. Seu início é decorrente do acúmulo de placa bacteriana, na qual se encontram microrganismos, principalmente gram-negativos, os quais estimulam as células do hospedeiro e a produção de moléculas imunoinflamatórias. Assim, o objetivo desta pesquisa foi avaliar a efetividade das duas técnicas de tratamento periodontal através de parâmetros clínicos e exames laboratoriais. Para isso, foram avaliados 42 pacientes, aleatoriamente, e divididos em três grupos de 14 pacientes cada: Grupo 1 (controle) - pacientes periodontalmente saudáveis, com os demais grupos de pacientes com periodontite crônica de moderada a severa, sendo o grupo 2 tratado com a técnica de tratamento periodontal convencional e o grupo 3 com a técnica desinfecção total de boca. Todos esses pacientes foram submetidos ao tratamento periodontal e avaliados através de índice de placa e gengival, profundidade de sondagem, nível de inserção clínica, sangramento a sondagem, análise da expressão da isoforma de PGE2 e análise do fluido gengival crevicular, sendo avaliados por um período total de 180 dias. Os resultados dos parâmetros periodontais e laboratoriais não demonstraram diferença estatisticamente significante (p>0,05) quando comparadas as técnicas no período de 180 dias. Logo, pode-se afirmar que ambos os tratamentos periodontais foram efetivos, mas sem superioridade entre eles. Entretanto, ambos melhoraram significativamente os parâmetros clínicos periodontais e laboratoriais. Assim, o profissional deve avaliar o caso de seu paciente e escolher o tratamento que melhor se adeque as suas necessidades e disponibilidade.
306

Avaliação de diferentes modalidades de tratamentos em pacientes com diabetes mellitus tipo 2 e doença periodonal / Evaluation of different treatment modalities in patients with type 2 diabetes mellitus and periodonal disease

Toyama, Gisele 14 February 2014 (has links)
Made available in DSpace on 2017-07-10T18:55:44Z (GMT). No. of bitstreams: 1 Gisele Toyama.pdf: 2839416 bytes, checksum: 2f5dbd1ea8e1b9c003fdb5d06ee443c4 (MD5) Previous issue date: 2014-02-14 / Type 2 diabetes (DM2) and periodontal disease are closely related. DM2 is a risk factor for periodontal disease whereas periodontitis increases hyperglicemia. Although it is known that the treatment of periodontitis improves glycemic control, there is no consensus of what type of treatment is best for diabetics. Objective: Evaluate different types of periodontal treatment in diabetics. Methodology: Two different researches were performed: 40 patients, aged 30 to 60, who were divided into 2 groups: group 1: controlled mechanical + basic periodontal treatment, Group 2: controlled mechanical + basic periodontal treatment + Doxycycline 100 mg orally for 14 days. In the first study, the analyses were made after 0, 3 and 6 months, including probing depth, level of clinical attachment, bleeding on probing. Glycated hemoglobin (HbA1c), fasting glucose and microbiological analysis (FG) were also taken. In study 2, a clinical analysis and an expression of isoforms of interleukin IL1β (IL-1β) test was performed. 20 patients were selected for the second part of the research. They were divided as follow: 1) Conventional periodontal treatment with scaling and root planning + Mechanical control and group 2) Periodontal Treatment (one-stage full-mouth disinfection) + Mechanical control . In this research, the analysis was performed after 0, 3 and 6 months including clinical evaluation, HbA1c and FG tests. The expression of isoforms of interleukin IL1β (IL-1β) were analyzed in the beginning of the study and after 6 months. Results: In the first article, it was shown an improvement in all clinical periodontal parameters evaluated as well as the level of HbA1c in both treated groups after 6 months. In the doxycycline group, there was a greater improvement in gingival index and test of glycated hemoglobin, as well as a smaller amount of Gram- .The second study showed a significant decrease in the expression of IL1- in gingival crevicular fluid in patients in treatment with Doxycycline. In the second research, after 6 months, it was observed better levels of FG, clinical periodontal parameters and gingival crevicular fluid in both groups. Nevertheless, no statistical significance was observed in the expression of IL-1β after 180 days. Conclusion: It is suggested that the basic periodontal therapy associated with the use of doxycycline is more efficient for clinical, glycemic and microbiological control in patients with type 2 Diabetes Mellitus with periodontal disease, as well as in the reduction of IL1- in gingival crevicular fluid. When different types of periodontal treatments are compared, it is possible to observe that the conventional periodontal treatment is the first choice in one-stage full-mouth disinfection for both glycemic control and periodontal parameters related to bleeding on probing and gingival crevicular fluid as well as the relation of variation envolving the expression of IL1-β even in the absence of significant difference among initial and final parameters in each group / O diabetes mellitus tipo 2 (DM2) e a doença periodontal possuem entre si uma relação íntima. O diabetes é um fator de risco para periodontite, assim como, a periodontite aumenta a hiperglicemia. O tratamento da periodontite pode melhorar o controle glicêmico, entretanto, não existe consenso de qual tratamento periodontal é o melhor em diabéticos. Objetivo: Avaliar diferentes modalidades de tratamento periodontal em diabéticos. Metodologia: Foram realizadas duas pesquisa, na primeira, foram selecionados 40 pacientes com DM2, e estes divididos em dois grupos: Grupo 1: Controle mecânico + Tratamento periodontal básico; Grupo 2: Controle mecânico + Tratamento periodontal básico + Doxiciclina 100 mg via oral por 14 dias. No primeiro artigo foram realizadas análises aos 0, 3 e 6 meses, incluindo Profundidade de sondagem, Nível de inserção clínica e Sangramento a sondagem, juntamente com a avaliação de hemoglobina glicada (HbA1c), glicemia em jejum (GJ) e análise microbiológica. No artigo 2, foram realizadas as análises clínicase a análiseda expressão das isoformas da interleucina IL1β (IL-1β). Na segunda pesquisa foram selecionados 20 pacientes com DM2, os quais foram divididos em dois grupos: Grupo 1: Tratamento periodontal básico (RAR) + Controle mecânico (Técnica de Bass + fio dental); Grupo 2: Tratamento periodontal básico (Desinfecção Total de Boca em Estágio Único - DBEU) + controle mecânico (Técnica de Bass + fio dental). Nesta pesquisa as análises também foram realizadas aos 0, 3 e 6 meses, com avaliação clínica periodontal e a avaliação de HbA1c e GJ. A expressão das isoformas de IL-1β foram analisadas no início e após 6 meses. Resultados: No primeiro artigo, houve uma melhora de todos os parâmetros clínicos periodontais e dos níveis de HbA1c em ambos os grupos tratados após 6 meses. No grupo que usou doxiciclina, houve uma melhora mais expressiva do índice gengival e daHbA1c, bem como uma quantidade menor de microrganismos Gram-. O segundo artigo evidenciou uma expressão significantemente menor de IL1- no fluido crevicular gengival dos pacientes em uso de doxiciclinina ao final do experimento. Na segunda pesquisa, após 6 meses, houve uma melhora da GJ, dos parâmetros clínicos periodontais e da quantidade de fluido crevicular gengival em ambos os grupos. Entretanto, não houve diferença estatisticamente significativa na expressão de IL-1β após 180 dias.Conclusão: Foi possível observar que a terapia periodontal básica associada ao uso de doxiciclina é mais eficiente para o controle clínico, glicêmico e microbiológico de pacientes portadores de DM2 e doença periodontal, bem como na menor expressão de IL1- no fluido crevicular gengival deste pacientes. Quando comparado os tipos de tratamento periodontal, foi possível observar que o tratamento periodontal convencional é superior à desinfecção total em estágio único, tanto em relação ao controle glicêmico, quanto em relação aos parâmetros periodontais de sangramento a sondagem e área de fluido gengival, bem como em relação a variação dos valores de expressão de IL1-β, apesar de não haver diferença significativa entre os valores iniciais e finais em cada grupo
307

Proposta metodológica e avaliação da inativação de endósporos de Geobacillus stearothermophilus no tratamento de resíduos de serviços de saúde por autoclavagem / Methodological proposal and evaluation of the inactivation of endospores of Geobacillus stearothermophilus in the treatment of healthcare waste by autoclaving

Amanda Borges Ribeiro de Oliveira 27 January 2017 (has links)
Resíduos de Serviços de Saúde (RSS), ainda que tratados e dispostos em aterros sanitários, podem ser causas de impactos ambientais por apresentarem algum indicador de periculosidade. Segundo o apêndice IV da Resolução da Agência Nacional de Vigilância Sanitária (Anvisa) RDC nº 306/2004, para as tecnologias de tratamento desses resíduos é necessário que se atinja pelo menos o Nível III de inativação microbiana. Perante a ausência de dados na literatura que revelassem o tempo de exposição, temperatura e pressão ideais para a inativação microbiana no tratamento de RSS por autoclavagem e se a fração ocupada dos resíduos na autoclave poderia interferir na eficiência da desinfecção definiu-se o objetivo do trabalho para otimização do processo. Para os testes foram utilizados endósporos de Geobacillus stearothermophilus como bioindicadores e instalados cinco termopares na autoclave para aferição da temperatura dentro de todo o espaço da câmara. O RSS foi sintetizado diante das caracterizações como composição gravimétrica, distribuição granulométrica, densidade específica aparente, massa específica aparente e teor de umidade. Apresentou-se uma proposta metodológica para a avaliação do tratamento de RSS frente às dificuldades encontradas. Realizou-se ensaios com 116ºC, 125ºC e 134ºC, observando a fração de inativação em seis tempos de exposição diferentes. Sabendo-se que é padronizada em estabelecimentos de saúde a temperatura ideal para esterilização de materiais de 121ºC, apesar de não terem sido encontrados trabalhos científicos que comprovem a eficiência da esterilização nessa circunstância, foram realizados testes a 50 e 60 minutos de exposição para avaliar essa condição. Inoculou-se 106 endósporos nas amostras e a recuperação foi feita com filtração após a lavagem dos resíduos, sendo realizada a técnica de pour plate para contagem das unidades formadoras de colônias (UFC). O mesmo procedimento foi feito com a amostra retirada da autoclave. A fração de inativação dos endósporos atingiu 100% no tempo de 30 minutos de exposição à temperatura máxima de 134ºC e pressão absoluta de 2,3 kgf/cm2, resultado obtido através da relação do número de micro-organismos recuperados considerados como inoculados e o número de micro-organismos sobreviventes ao tratamento. A 121ºC houve recuperação de UFC após tratamento. A fração de ocupação não foi um fator delimitante para a inativação de endósporos, pois a temperatura se manteve a mesma independentemente da quantidade de resíduo submetido à autoclavagem. Um outro objetivo era avaliar experimentalmente a reprodução dos micro-organismos frente às condições operacionais de autoclavagem e do tempo de permanência do rejeito em condições ambientais. Esse estudo comprovou que a inativação nessas condições otimizadas esteriliza o resíduo, sendo que nenhum micro-organismo voltou a se reproduzir após dias expostos em temperatura ambiente, ou seja, não haveria riscos de contaminação em aterro sanitário quando depositados os rejeitos. Ter encontrado essas condições ideais e avaliado o processo de autoclavagem pode significar um grande avanço nas próprias unidades de tratamento, que terão um parâmetro estabelecido para trabalho. / Healthcare waste, even when treated and disposed of in landfills, can be causes of environmental impacts because they present some hazard indicator. According to appendix IV of Resolution of the National Health Surveillance Agency of Brazil (Anvisa) RDC nº 306/2004, for technologies of healthcare waste treatment, it is necessary to achieve at least Level III of microbial inactivation. The purpose of this research to optimize the process was defined taking into account the absence of data in the literature that revealed the optimal exposure time, temperature and pressure for microbial inactivation through the healthcare treatment by autoclaving and whether the fraction occupied by waste in the autoclave could interfere with the effectiveness of the disinfection. For the tests, endospores of Geobacillus stearothermophilus were used as bioindicators and five thermocouples were installed in the autoclave for temperature measurement throughout the chamber space. The healthcare waste was synthesized by characterizations such as gravimetric composition, granulometric distribution, apparent specific density, apparent specific mass and moisture content. A methodological proposal for the evaluation of waste treatment was introduced taking into consideration the difficulties encountered. Tests were performed at 116ºC, 125ºC and 134ºC, observing the fraction of inactivation at six different exposure times. Since the sterilization of materials at 121ºC is standardized in health establishments, even though no scientific studies were found to prove the sterilization efficiency in these conditions, tests were performed at 50 and 60 minutes of exposure to evaluate this condition. The concentration of 106 endospores were inoculated in the samples and the recovery was done with filtration after washing the waste, and the \"pour plate\" technique was used to count the colony forming units. The same procedure was done with the sample removed from the autoclave. The inactivation fraction of the endospores reached 100% in the time of 30 minutes of exposure to the maximum temperature of 134ºC and absolute pressure of 2.3 kgf/cm2, a result obtained by the ratio of the number of recovered microorganisms considered as inoculated and the number of microorganisms surviving the treatment. At 121ºC there was recovery of colony forming units after treatment. The occupation fraction was not a limiting factor for the inactivation of endospores, since the temperature remained the same regardless of the amount of waste submitted to autoclaving. Another objective was to experimentally evaluate the reproduction of the microorganisms taking into consideration the operational conditions of autoclaving and the amount of time that the waste remains under environmental conditions. This study proved that the inactivation under these optimized conditions sterilizes the waste, and that no microorganism would reproduce again after days exposed at room temperature, therefore, there would be no risk of contamination in a landfill when the waste is deposited. Having found these ideal conditions and evaluated the autoclaving process can mean a major advance in the treatment units themselves, which will have an established parameter for work.
308

Comparação da resistência de protozoários patogênicos - Giardia spp. e Cryptosporidium spp. - e de microrganismos indicadores à desinfecção sequencial cloro-radiação ultravioleta e ozônio-radiação ultravioleta / Comparion of the resistance of pathogenic protozoa - Giardia spp. and Cryptosporidium spp. - and indicators microorganisms to sequential disinfection with chlorine-ultraviolet radiation and ozone-ultraviolet radiation

Raphael Corrêa Medeiros 30 April 2010 (has links)
Este trabalho teve por objetivo estudar a desinfecção seqüencial cloro-radiação ultravioleta e ozônio-radiação ultravioleta a fim de avaliar a resistência de microrganismos indicadores de poluição fecal - E. coli, coliformes totais e Clostridium perfringens - e compará-la à dos protozoários patogênicos: Giardia spp. e Cryptosporidium spp.. Houve, primeiramente, monitoramento do reator anaeróbio UASB cujo efluente foi utilizado neste estudo. Foi, então, verificado o comportamento das espécies residuais de cloro no esgoto e conduzido um estudo de parâmetros indicadores (pH, potencial de oxi-redução e condutividade) para o breakpoint. Na desinfecção, foram empregados o cloro, ozônio e radiação ultravioleta; separados, e seqüencialmente. Os ensaios realizados com ozônio promoveram remoção de DQO, sólidos e dos valores de absorbância em 254 nm, diferentemente do cloro. A ordem crescente de resistência à desinfecção foi: E. coli < coliformes totais < C. perfringens < protozoários. Houve correlação em alguns ensaios entre a bactéria esporulada C. perfringens e Giardia spp.. O efeito sinérgico, promovido pela desinfecção seqüencial, foi evidenciado em alguns experimentos para C. perfringens e Giardia spp. / The present dissertation reports on the study of the sequential disinfection with chlorine-ultraviolet radiation and ozone-ultraviolet radiation to evaluate the resistance of microorganisms that indicate fecal pollution - E. coli, total coliforms and Clostridium perfringens - and compare it to the resistance of pathogenic protozoa: Giardia spp. and Cryptosporidium spp.. Firstly, the UASB reactor, whose effluent was utilized in this study, was monitored. Then the behavior of the residual species of chlorine in the sanitary sewage was verified and a study of the indicating parameters (pH, oxi-reduction potential and conductivity) for the breakpoint was conducted. Chlorine, ozone and ultraviolet radiation were used separately and sequentially in the disinfection. Tests performed with ozone promoted removal of COD, solids and absorbance values of 254 nm, differently from chlorine. The order of resistance to disinfection was: E. coli < total coliforms < Clostridium perfringens < protozoa. There was a correlation in some tests between spore-forming bacterium Clostridium perfringens and Giardia spp.. The synergic effect caused by the sequential disinfection was observed in some experiments for C. perfringens and Giardia spp.
309

Avaliação da resistência de microrganismos patogênicos à desinfecção sequencial com ozônio-radiação ultravioleta e cloro-radiação ultravioleta / Resistance evaluation of pathogenic microorganisms to sequential disinfection with ozone-ultraviolet radiation and chlorine-ultraviolet radiation

Juliana Lourenção 05 June 2009 (has links)
A remoção de microrganismos patogênicos através da desinfecção é uma necessidade para diminuir a incidência de doenças na população humana relacionadas com poluição fecal. A desinfecção sequencial tem grande potencial na remoção de microrganismos, quando comparada com a desinfecção convencional (um desinfetante). Neste trabalho buscou-se comparar a resistência de microrganismos indicadores de bactérias - E. coli e coliformes totais - e bactérias esporuladas - Clostridium perfringens quanto à desinfecção sequencial empregando cloro seguido de radiação ultravioleta e ozônio seguido de radiação ultravioleta; e à desinfecção convencional utilizando-se os mesmos desinfetantes aplicados individualmente em esgoto sanitário tratado previamente em reator UASB. Os ensaios foram realizados em batelada. As dosagens de cloro aplicadas foram de 10, 20 e 30 mg\'CL IND.2\'/L; de ozônio foram de 5,6; 11 e 16,5 mg\'O IND.3\'/L, ambos para os tempos de contato 10, 20 e 30 minutos. Na desinfecção sequencial com cloro foram aplicadas as doses de 1, 5 e 10 Wh/\'M POT.3\' de radiação UV; com ozônio, as doses de radiação foram variadas de 0,5 a 10 Wh/\'M POT.3\'. Na desinfecção sequencial de cloro-UV, foram removidos 2,5 e 5,2 log de C. perfringens e coliformes totais, respectivamente contra 1,5 e 4,2 log na desinfecção convencional para os mesmos microrganismos. Na desinfecção com cloro, a ordem decrescente de resistência foi: C. perfringens > coliformes totais > E. coli. Para ozônio seguido de UV, C. perfringens apresentou maior resistência e, em alguns ensaios, E. coli apresentou-se mais resistente que coliformes totais. A ação do ozônio mostrou-se notável para a melhoria da qualidade do esgoto tratado avaliada pela diminuição das concentrações de sólidos suspensos totais, sólidos totais, absorbância em comprimento de onda de 254 nm e da DQO, diferentemente do esgoto clorado no qual ocorreu o aumento nos valores destas variáveis físico-químicas. A ação da radiação ultravioleta foi potencializada quando aplicada sequencialmente ao cloro e ao ozônio. / The removal of pathogenic microorganisms through disinfection is a necessity to decrease the incidence of diseases in the human population related to fecal pollution. Sequential disinfection has a great potential on the removal of microorganisms when compared to conventional disinfection (single disinfectant). This work compared the resistance of indicators microorganisms of bacteria - E. coli and total coliforms - and spore-forming bacteria - Clostridium perfringens concerning the sequential and conventional disinfections. The sequential disinfection initially employed chlorine followed by ultraviolet radiation and ozone followed by ultraviolet radiation. The conventional disinfection utilized the same disinfectants individually applied in sanitary sewage previously treated in UASB reactor. The tests were made in batch. The chlorine dosages applied were 10, 20 and 30 mg\'CL IND.2\'/L; ozone were 5,6; 11 and 16,5 mg\'O IND.3\'/L, both for the contact times 10, 20 and 30 minutes. In the sequential disinfection with chlorine dosages of 1, 5 and 10 Wh/\'M POT.3\' of UV radiation were applied; with ozone, the dosages of radiation varied from 0,5 to 10 Wh/\'M POT.3\'. In the sequential disinfection with UV-chlorine were inactived 2,5 and 5,2 log of C. perfringens and total coliforms respectively, against 1,5 and 4,2 log in the conventional disinfection for the same microorganisms. In the chlorine disinfection, the decreasing resistance order was: C. perfringens > total coliforms > E. coli. In the ozone disinfection followed by UV, C. perfringens manifested more resistance and, in some assays, E. coli was more resistant than total coliforms. The action of ozone was outstanding for the improvement of treated sewage quality assessed by the decreasing of total suspended solids concentration, total solids absorbance at a wavelength of 254 nm and of DQO, differently from the chlorine sewage in which occurred an increase of the values of the physical-chemical variables. The ultraviolet radiation action was potentiated when sequentially applied to chlorine and to ozone.
310

Avaliação da contaminação microbiana de aparelhos ortodônticos removíveis, com e sem utilização de agente antimicrobiano, pela técnica Checkerboard DNA-DNA Hybridization - Estudo Clínico Randomizado / Detection of microbial contamination of removable orthodontic appliances with or without use of antimicrobial agent, by the Checkerboard DNA-DNA Hybridization, A randomized clinical study

Marcela Perdiza 14 October 2009 (has links)
O objetivo do presente estudo clínico randomizado foi avaliar in vivo, por meio da técnica de biologia molecular Checkerboard DNA-DNA Hybridization: 1) A contaminação de aparelhos ortodônticos removíveis por 40 espécies bacterianas; 2) A eficácia da utilização do gluconato de clorexidina a 0,12% (Periogard®) sobre microrganismos cariogênicos; e 3) A eficácia da utilização do gluconato de clorexidina a 0,12% (Periogard®) sobre microrganismos periodontopatogênicos dos complexos laranja e vermelho. Participaram do estudo 20 pacientes de 7 a 11 anos de idade, em tratamento com aparelhos ortodônticos removíveis. O estudo constou de 2 etapas, com intervalo de 15 dias entre cada uma, de forma que todos os pacientes participassem tanto do grupo controle, quanto do grupo experimental. Em cada etapa os pacientes receberam um novo aparelho (totalizando 2 aparelhos por indivíduo) e um frasco plástico contendo a solução a ser borrifada sobre os aparelhos, porém os indivíduos não sabiam qual solução estavam utilizando. Os aparelhos foram utilizados em período integral, inclusive à noite, sendo removidos apenas durante as refeições Os pacientes do Grupo Controle foram orientados a usar solução placebo, sob a forma de spray, 2 vezes por semana, por 7 dias. Os pacientes do Grupo Experimental foram orientados a usar solução à base de gluconato de clorexidina a 0,12% (Periogard®) sob a forma de spray, da mesma forma que o grupo Controle. Decorridos 7 dias, os aparelhos de cada etapa foram removidos e processados para detecção de 40 espécies bacterianas, incluindo microrganismos cariogênicos e periodontopatogênicos, pela técnica Checkerboard DNA-DNA Hybridization. Os resultados obtidos foram analisados por meio do teste não-paramétrico de Wilcoxon, utilizando o software SAS (Statistical Analysis System). O nível de significância adotado foi de 5%. De acordo com os resultados obtidos observou-se que os aparelhos ortodônticos removíveis dos pacientes do grupo controle estavam densamente contaminados pelos microrganismos avaliados. A maioria das sondas utilizadas estava presente nas amostras desse grupo, sendo que S. sanguinis, S. oralis, S. gordonii e E. corrodens ocorreram em 100% dos aparelhos. Dentre os microrganismos cariogênicos, S. mutans e S. sobrinus foram encontrados em maiores quantidades que L. acidophilus e L. casei. As bactérias periodontopatogênicas pertencentes ao complexo vermelho foram evidenciadas em maiores quantidades que as pertencentes ao complexo laranja. Dentre os demais complexos não associados com patologias específicas, o complexo roxo apresentou-se em maiores quantidades, estando presente em 34% das amostras. Após o uso de spray com gluconato de clorexidina a 0,12%, observou-se uma diminuição significante dos microrganismos cariogênicos (S.mutans e S. sobrinus e L. acidophilus) nos aparelhos ortodônticos removíveis (p<0,05). Observou-se também uma diminuição significante de todos os microrganismos periodontopatogênicos dos complexos laranja e vermelho (p<0,05), em relação ao grupo controle, com exceção apenas do T. socranskii. Conclui-se que os aparelhos ortodônticos removíveis encontraram-se multicolonizados por diversas espécies bacterianas e que a clorexidina, utilizada duas vezes por semana sob a forma de spray, foi eficaz na redução dos níveis de microrganismos cariogênicos e periodontopatogênicos dos complexos laranja e vermelho, nesses aparelhos. / Using the Checkerboard DNA-DNA Hybridization biomolecular technique, this randomized clinical study evaluated: 1) the contamination of removable orthodontic appliances by 40 bacterial species; 2) the efficacy of 0.12% chlorhexidine gluconate (Periogard®) spray against cariogenic microorganisms;and 3) the efficacy of 0.12% chlorhexidine gluconate spray against periodontopathogenic microorganisms of the orange and red complexes. Twenty 7-11-year-old patients under treatment with removable orthodontic appliances were enrolled. The study had two phases, with a 15-day interval between them, in such a way that patients participated both in the control and in the experimental group. In each phase, the patients received a new appliance (total of 2 appliances per patient) and a bottle containing a solution to be sprayed onto the appliances, but they were blinded to whether it was a placebo solution or an antimicrobial agent. The patients were instructed to wear the appliances full-time, even at night, removing only at meals. The patients in the control and experimental groups were instructed to spray the placebo or the 0.12% chlorhexidine gluconate-based solution (Periogard®), respectively, onto the appliances twice a week during 7 days. After this period, the appliances of each phase were collected and processed for detection of 40 bacterial species, including cariogenic and periodontopathogenic microorganisms by the Checkerboard DNA-DNA Hybridization technique. Data were analyzed statistically by the non-parametric Wilcoxon test using the SAS software (Statistical Analysis System) at 5% significance level. The results showed that the removable orthodontic appliances of the patients in the control group were heavily contaminated by the target microorganisms. Most bacterial probes used were present in the control samples, S. sanguinis, S. oralis, S. gordonii and E. corrodens being detected in 100% of the appliances. Among the cariogenic microorganisms, S. mutans and S. sobrinus were found in larger numbers than L. acidophilus and L. casei. The number of red complex periodontopathogenic bacteria was larger than that of orange complex periodontopathogenic bacteria. Among the other bacterial complexes not associated with specific pathologies, purple complex bactéria were present in larger numbers, being detected in 34% of the samples. After use of the 0.12% chlorhexidine gluconate spray, the number of the cariogenic microorganisms (S.mutans, S. sobrinus and L. acidophilus) decreased significantly in the removable orthodontic appliances (p<0,05). There was also a significant decrease in the numbers of all periodontopathogenic microorganisms of the orange and red complexes (p<0,05), compared to the control group, except for T. socranskii. In conclusion, the removable orthodontic appliances were multicolonized by several bacterial species, and the use of chlorhexidine spray twice a week was effective in reducing the levels of cariogenic and periodontopathogenic microorganisms of the orange and red complexes.

Page generated in 0.1168 seconds