• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 393
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 400
  • 400
  • 400
  • 200
  • 179
  • 91
  • 63
  • 61
  • 59
  • 54
  • 54
  • 49
  • 46
  • 43
  • 43
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
351

Estudo comparativo do diagnóstico de edema macular secundário a oclusão de ramo da veia central da retina pela biomicroscopia de mácula, angiofluoresceinografia e tomografia de coerência óptica / Comparison of optic coherence tomography, macular biomicroscopy and fluorescein angiography for macular edema secondary to branch retinal vein occlusion

Pinheiro, Alexandre Grobberio 04 October 2007 (has links)
As Oclusões Venosas da Retina são complicações do sistema vascular retiniano com grande potencial de impacto no sentido da visão. As oclusões Venosas são classificadas de acordo com a anatomia da região acometida e podem ser divididas em oclusão de ramo e da veia central da retina. O edema macular é a principal causa de baixa acuidade visual na Oclusão de Ramo da Veia Central da Retina (OVR). Sua detecção, localização e classificação são cruciais para a prevenção e tratamento da perda visual na OVR. A Biomicrospia Macular e a Angiofluoresceinografia são os métodos tradicionais de avaliação do edema macular na OVR, a Tomografia de Coerência Óptica (TCO) é uma tecnologia nova, que permite uma avaliação objetiva da morfologia macular. O objetivo primário do presente estudo foi avaliar, em uma mesma população, a acurácia dos métodos de diagnóstico do edema macular na OVR através da análise de três quesitos, aumento da espessura macular e da sua localização, presença de cistos intra-retinianos e a presença de descolamento seroso macular (DSM). Indivíduos com OVR foram selecionados com base nos achados fundoscópicos da doença e com tempo de história da doença entre três e vinte quatro meses. Todos os sujeitos foram submetidos a exames com o Stratus OCT (TCO), Angiofluoresceinografia digital (Angio) e o exame da biomicroscopia macular com lente de Volk de 78 D (BM) dentro do período de uma semana, além de exame oftalmológico completo. As medidas utilizadas para avaliação da acurácia diagnóstica foram o índice de concordância Kappa e a sensibilidade. Dos 32 indivíduos inicialmente avaliados, 8 foram posteriormente excluídos por não cumprirem os critérios de inclusão ou de exclusão, restando 24 indivíduos para análise. Na avaliação da espessura macular, a concordância entre BM e a TCO foi substancial e significante para a detecção do aumento da espessura macular com Kappa = 0,778 (p < 0,001) e a sensibilidade foi 95,5%. Na comparação entre a BM e a TCO para a detecção de cistos intra-retinianos, a concordância foi fraca com Kappa = 0,250 (p = 0,066) e a sensibilidade foi 57,9 %. A concordância entre a Angio e a TCO para os cistos foi pobre e não significante com Kappa = 0,124 (p = 0,237) e a sensibilidade foi 58,7 %. Houve uma correlação significante entre a presença de extravasamento na angiofluoresceinografia e a presença de cistos intra-retinianos na TCO (p=0,042). Na avaliação do DSM a concordância entre a BM e a TCO foi fraca com Kappa = 0,314 (p = 0,062) e a sensibilidade foi 60%, não houve concordância entre a Angio e a TCO para a detecção do DSM com Kappa = 0 e sensibilidade de 0%, e também não houve correlação significante entre a presença de descolamento seroso na TCO e a presença de extravasamento na angiofluoresceinografia (p=0,615). Os dados obtidos no presente estudo sugeriram que o Stratus OCT têm acurácia superior para a detecção dos cistos intra-retinianos e do descolamento seroso macular, se comparado à biomicroscopia macular e à angiofluoresceinografia / Retinal Vein Occlusions are complications of the retinal vascular system that can cause a great impact on vision. The Vein Occlusions are classified according to the anatomy of the affected region and can be categorized as: branch retinal vein occlusion and central retinal vein occlusion. Macular edema is the main cause for low visual acuity in Branch Retinal Vein Occlusion (BRVO). Its detection, location and classification are crucial for the prevention and treatment of vision loss in BRVO. Both Macular Biomicroscopy and Angiofluoresceinography are traditional methods for the evaluation of the macular edema in BRVO; the Optical Coherence Tomography (OCT) is a new technology that allows for an objective evaluation of macular morphology. The main objective of the present study was to evaluate, among the same population, the accuracy of the diagnostic methods of macular edema in BRVO through the analysis of three items: the increase of macular thickness and its location, the presence of intraretinal cysts, and the presence of serous macular detachment. Patients with BRVO were selected according to the fundoscopic findings of the disease and a disease history of three to twenty-four months. All of the individuals underwent exams with the Stratus OCT, digital Angiofluoresceinography (Angio) and a macular biomicroscopy with a 78D Volk lens (MB), within a period of one week, as well as a complete ophthalmologic exam. The parameters used in the evaluation of the diagnostic accuracy were sensitivity and the kappa coefficient. Of the 32 subjects who were initially evaluated, 8 were later excluded since they did not meet inclusion or exclusion criteria. The remaining 24 subjects were analyzed. In the evaluation of macular thickness, the concordance between the MB and the OCT was substantial and significant in the detection of the increase in macular thickness, with Kappa = 0.778 (p<0.001) and a sensitivity of 95.5%. When comparing the MB and the OCT in the detection of intraretinal cysts, the concordance was fair, with Kappa = 0.250 (p = 0.066) and a sensitivity of 57.9%. The concordance between the Angio and the OCT for cysts detection was poor and non significant, with Kappa = 0.124 (p = 0.237) and a sensitivity of 58.7%. There was a significant correlation between the presence of leakage in the angiofluoresceinography and the presence of intraretinal cysts in the OCT (p = 0.042). In the evaluation of the SMD, the concordance between the MB and the OCT was fair, with Kappa = 0.314 (p = 0.062) and a sensitivity of 60% an there was no concordance between the Angio and the OCT in the detection of SMD, with Kappa = 0 and sensitivity of 0%. There was also no significant correlation between the presence of serous detachment in the OCT and the presence of leakage in the angiofluoresceinography (p = 0.615). The results obtained in the present study suggest that Stratus OCT is more accurate to the detection of intraretinal cysts and serous macular detachment than macular biomicroscopy with a 78D Volk lens, and by angiofluoresceinography
352

Avaliação tomográfica do acometimento das pequenas vias aéreas nas doenças intersticiais do pulmão / Tomographic evaluation of the small airways in the interstitial lung diseases

Rocha, Marcelo Jorge Jacó 14 August 2007 (has links)
A patogênese da fibrose pulmonar idiopática (FPI), forma mais comum de pneumonia intersticial idiopática, não é bem conhecida. Os estudos histopatológicos evidenciam uma extensa lesão do epitélio alveolar com destruição intensa dos pneumócitos tipo e exposição e perda de integridade da membrana basal subjacente, impedindo a reepitelização e rendotelização alveolar, com conseqüente proliferação de fibroblastos e deposição de matriz extracelular. O fator etiológico responsável por essa resposta fibrosante ainda não é conhecido. Em doenças como a síndrome do desconforto respiratório agudo (SDRA) e a lesão pulmonar induzida pela ventilação mecânica, o papel da abertura e fechamento cíclicos das pequenas vias aéreas já está bem estabelecido. Esse estudo tem como objetivo avaliar a presença de colapso alveolar e de pequenas vias aéreas em pacientes com FPI através de tomografia computadorizada (TC) de tórax multislice. As tomografias foram realizadas em 3 diferentes momentos do ciclo respiratório - na capacidade pulmonar total (CPT), na capacidade residual funcional (CRF) e no volume residual (VR) - inicialmente em ar ambiente (O2 a 21%) e as duas últimas etapas, CRF e VR, foram repetidas após 10 minutos de ventilação com O2 a 100%. Admitimos que o surgimento de colapso alveolar após a manobra com O2 a 100% se deve ao fechamento das pequenas vias aéreas seguido de atelectasia de absorção. Foi utilizado o programa Osiris para análise quantitativa das densidades pulmonares e um programa em linguagem LabVIEW 6.0 para quantificação da massa de pulmão não aerado (colapsado) cuja densidade situa-se entre -100 e + 100 UH. A casuística foi composta por 18 pacientes com diagnóstico histológico e/ou clínico de FPI e 12 controles sem doença respiratória conhecida. Os indivíduos do grupo controle foram mais idosos (63 x 70 anos), não havendo diferença quanto à história de tabagismo. A atenuação média do parênquima pulmonar foi maior no grupo fibrose na CPT, CRF 21% e VR 21%. Quando analisamos a massa de pulmão não aerado, o grupo fibrose apresentou valores significativamente maiores do que o grupo controle em todos os volumes respiratórios avaliados em ar ambiente e após O2 a 100%. A avaliação da massa de pulmão não aerado no VR e na CRF após ventilação com O2 a 100%, em comparação com os mesmos volumes pulmonares em ar ambiente, mostrou aumento do colapso tanto em pacientes quanto em controles, não havendo diferença entre os grupos quando se comparou o aumento absoluto da massa de pulmão não aerado após essa manobra. Entretanto, no grupo de pacientes com FPI, houve aumento significativo da massa de pulmão não aerado à medida que se reduziram os volumes pulmonares em ar ambiente, alteração essa não encontrada no grupo controle. Podemos concluir que a ventilação com O2 a 100% causou colapso de vias aéreas tanto nos pacientes quanto no grupo controle. Nos pacientes com FPI, foi evidenciado colapso alveolar durante a ventilação em ar ambiente, colapso esse quase totalmente revertido (88%) após uma manobra de inspiração máxima até a CPT, o que demonstra seu potencial de reversibilidade / The pathogenesis of idiophatic pulmonary fibrosis (IPF), the most common form of idiopathic interstitial pneumonias, is not completely understood. It is related to a type I pneumocyte injury with loss of basement membrane integrity and failure of normal re-epithelialization and re-endothelialization leading to fibroblast proliferation and extra cellular matrix deposition. However, the etiology of this fibroproliferative response is unknown. In ARDS and ventilator-induced lung injury, it has been postulated that the pulmonary injury is caused by the cyclic opening and closing of collapsed airways. Our aim is to measure the collapsed areas of the lung (alveolar and small airways collapse) using a multislice computed tomography (CT) in a group of patients with IPF. They were submitted to a CT scan of the thorax in 5 different situations: at total lung capacity (TLC), functional residual capacity (FRC) and residual volume (RV) at 21% O2 as well as at FRC and RV after breathing 100% O2 for 10 minutes. We assumed that the gain in collapsed areas after 100% O2 corresponds to trapped areas with airways closure and absorption atelectasis. We employed the Osiris Software program to the quantitative analysis of CT attenuation of lung tissue and a program written in LabVIEW to measure the mass of nonaerated lung tissue (- 100 to +100 HU). Eighteen IPF patients and twelve controls without respiratory disease were studied. The control group was older than IPF group (70 x 63 years, respectively) and the smoking history was not different between both groups. The mean lung attenuation was higher in IPF patients at TLC, 21% FRC and 21% RV. When we analyzed the mass of nonaerated lung tissue, the IPF group showed significantly higher values in all respiratory maneuvers (TLC, FRC and RV) at 21% O2 and 100% O2. Both groups presented an increase in collapsed areas when exposed to 100% at RV and FRC and this increment was of similar magnitude. However, only IPF patients had an increase in the mass of nonaerated lung tissue when the lung volume was reduced from TLC to FRC and from FRC to RV during air breathing. We concluded that patients and controls had airways collapse after 100% O2 breathing. In contrast, only IPF patients demonstrated alveolar collapse during air breathing which was almost completed reversible after TLC maneuver
353

Elaboração de um guia para o uso do tensor de difusão em ressonância magnética para os profissionais da área

Brey, Andressa Caron 24 July 2014 (has links)
O imageamento por tensor de difusão (DTI) por ressonância magnética (RM) é um método de aquisição recente e de utilização bastante reduzida nos serviços que possuem equipamentos os softwares paro DTI. A partir desta situação notou-se a necessidade de um guia para os profissionais envolvidos RM; que servisse como fonte de consulta para auxiliar na aquisição do DTI. Para criação deste guia um referencial fez necessário e foi obtido apenas como norteador por meio de um questionário aplicado a profissionais que trabalham com RM, de uma clínica de Curitiba. Através do questionário foi possível levantar que conceitos e parâmetros o guia poderia explanar, notoriamente precisando dar ênfase aos parâmetros básicos da técnica, as formas de reconstrução dos dados e as formas de visualização. O guia foi montado explicando o processo de aquisição do DTI, os principais parâmetros envolvidos e os termos comuns aos exames desta natureza. Também foram elaboradas 15 perguntas frequentes sobre o DTI, com tabelas de consulta rápida. O resultado final é um guia de fácil manuseio e entendimento que visa auxiliar os profissionais da área a pesquisarem, apreenderem e utilizarem a técnica de imageamento por tensor de difusão. Apesar de pronto, existe ainda a necessidade de introduzir o guia e coletar sugestões e ainda aprimorar os questionamentos iniciais aos profissionais da área de modo a enriquecer o guia. / Diffusion tensor imaging (DTI) by magnetic resonance (MR) is a recent method of acquisition whose utilization has been fairly reduced in services that use equipment with DTI software. From this situation, one observed the need to develop a guide for professionals involved in MR, which would serve as a reference source to assist in the acquisition of DTI. In order to make this guide, a reference was necessary to be given a steer and it was obtained through a questionnaire administered to professionals who work with MRI in a clinic in Curitiba. Through the questionnaire, it was possible to raise the concepts and parameters the guide could explain, especially emphasizing technique basic parameters, forms of data reconstruction and visualization forms. The guide was made explaining the acquisition of DTI, the main parameters involved and the common terms for these kinds of tests. In addition, 15 commonly asked questions about the DTI were prepared with quick reference tables. The final result is an easy-to-understand guide which aims to help the area professionals to search, apprehend and use the diffusion tensor imaging technique. Although it is ready, there is the need to introduce the guide and collect suggestions, and still, improve the professionals’ early questions to enhance the guide.
354

Avaliação do padrão de desempenho das equipes técnicas de mamografia frente ao uso de tecnologias digitais / Grading of the performance of the technical mamography teams, in lieu of the use of digital technologies

Oliveira, Evelyn Rosa de 07 April 2017 (has links)
Este estudo apresenta uma análise de rejeição, realizada na clínica Diagnóstico Avançado Por Imagem – DAPI, com dados de 647 mamografias rejeitadas realizadas de março a novembro de 2015, antes e após treinamentos realizados com a equipe técnica de mamografia, para análise do desempenho. As informações foram coletadas na base de dados do software de análise de rejeição dos mamógrafos, e incluem: incidência; quantidade de repetições; motivo da repetição; identificação da profissional; compressão do exame rejeitado e do exame aceito. Observou-se que após o treinamento os índices de rejeição por posicionamento (a maior causa das rejeições) foram reduzidos em 2%. Identificou-se que as profissionais desenvolveram critérios mais rigorosos, o que também contribuiu para aumento das repetições após o treinamento. A incidência mais rejeitada foi a Crânio Caudal Direita – CCD, tanto antes (32%) quanto após o treinamento (36%). A análise do desempenho da equipe técnica em relação aos critérios de qualidade em mamografia digital pôde ser realizada, uma vez que houve a análise individual das profissionais para contribuição da qualificação da equipe e aumento da qualidade dos exames. A profissional “A”, que possuía o maior índice de rejeição por posicionamento, após o treinamento houve uma redução de 17% das repetições devido a posicionamento inadequado. Foram identificadas imagens com qualidade aceitável que foram rejeitadas desnecessariamente: 8% antes e 3,6% após o treinamento. Antes do treinamento, a equipe técnica realizava as mamografias com valores de compressão entre 80 a 89 N, e após o treinamento a maioria dos exames foi realizada com 90 N ou mais. Esse aumento resulta em exames com melhor qualidade e menor dose para a paciente. / This study presents a rejection analysis performed at the clinic Diagnóstico Avançado Por Imagem - DAPI, with data from 647 rejected mammograms performed three months before and three months after a training session of the mammography team, to analyze the performance of them after the training. The information was collected in the database of mammography rejection analysis software,these data include: Incidence; Number of repetitions; Reason for the repetition; Identification of the professional; Rejection examination and accepted examination. It was observed that, after the training, the rejection indexes by positioning (the greatest cause of the rejections) were reduced. It was observed that the group developed rigorous criteria, which also contributed to increase the repetitions after the training. The most rejected incidence was Cranio Caudal Right - CCD, both before (32%) and after training (36%).The analysis of the performance of the technical team, in relation to the quality criteria in digital mammography, could be performed by the individual analysis of the professionals to contribute to the qualification of the team and to increase the quality of the exams. The "A" professional, who had the highest index of rejection by positioning, after the training there was a reduction of 17% of the repetitions due to improper positioning. Acceptable quality images have been identified that are rejected unnecessarily 8% before and 3,6% after training. Before the training, the technical team performed the mammograms with values of compression between 80 and 89 N, and after training most of the exams were performed with 90 N or more. This increase which results in better quality tests and lower dose for the patient.
355

Aplicação de mapas auto-organizáveis na classificação de aberrações cromossômicas utilizando imagens de cromossomos humanos submetidos à radiação ionizante / Application of self-organizing maps for the classification of chromosomal aberrations using images of human chromosomes subjected to ionizing radiation

Kelly de Paula Cunha 15 April 2015 (has links)
O presente trabalho é resultado da colaboração de pesquisadores do Centro de Engenharia Nuclear (CEN) e de pesquisadores do Centro de Biotecnologia (CB), ambos pertencentes ao IPEN, para o desenvolvimento de uma metodologia que visa auxiliar os profissionais citogeneticistas fornecendo uma ferramenta que automatize parte da rotina necessária para a avaliação qualitativa e quantitativa de danos biológicos em termos de aberração cromossômica. A técnica citogenética, sobre a qual esta ferramenta é desenvolvida, é a técnica de aberrações cromossômicas. Nela, são realizadas preparações citológicas de linfócitos de sangue periférico para que metáfases sejam analisadas e fotografadas ao microscópio e, com base na morfologia dos cromossomos, anomalias sejam investigadas. Quando esta tarefa é realizada manualmente, os cromossomos são analisados visualmente um a um pelo profissional citogeneticista, logo, trata-se de um processo minucioso em virtude da variação geral na aparência do cromossomo, do seu tamanho pequeno e do grande número de cromossomos por célula. Para um diagnóstico confiável, é necessário que várias células sejam analisadas, tornando-se uma tarefa repetitiva e demorada. Neste contexto, foi proposto o uso dos mapas auto-organizáveis para o reconhecimento automático de padrões morfológicos referentes às imagens de cromossomos humanos. Para isso, foi desenvolvido um método de extração de características por meio do qual é possível classificar os cromossomos em: dicêntricos, anéis, acrocêntricos, submetacêntricos e metacêntricos, com acerto de 93,4 % em relação ao diagnóstico dado por um profissional citogeneticista. / This work is a joint collaboration between Nuclear Energy Research Institute (IPEN), Nuclear Engineering Center and Biotechnology Center to develop a methodology aiming to assist cytogenetic professionals by providing a tool to automate part of the required routine to perform qualitative and quantitative evaluation of biological damage in terms of chromosomal aberration. The cytogenetic technique upon which this tool was developed, is the chromosome aberrations technique, in which cytological preparations of peripheral blood lymphocyte metaphases are performed to be analyzed and photographed under a microscope in order to investigating chromosomal aberration. Performed manually, the chromosomes are analyzed visually one by one by a cytogenetic professional, so it is a painstaking process due to the great deal of variation in the appearance of each chromosome, their small sizes and not to mention the high density of chromosomes per cell. In order to obtain a reliable diagnosis it is necessary that many cells be analyzed, which makes this a repetitive and time consuming process. In this context, the use of self-organizing maps for the automatic recognition of patterns relating to morphological pictures of human chromosomes has been proposed. For this, we developed a feature extraction method by which is possible to classify chromosomes in: dicentrics, ring-shaped, acrocentric, submetacentric and metacentric with 93.4% accuracy compared to diagnostic given by a professional cytogeneticist.
356

Desenvolvimento de ferramenta computacional para o pré-diagnóstico de câncer de pele / Development of a computational tool for skin cancer pre-diagnosis

Gilvan Sampaio Santos 28 August 2008 (has links)
Um dos mais freqüentes tumores existentes é o câncer de pele. Quando identificado precocemente este tipo de câncer apresenta altos percentuais de cura. Para isso é necessário o reconhecimento de suas características. As características analisadas fundamentam-se em identificadores como: Assimetria da lesão (A); Irregularidade das Bordas (B); Cor (C) e Diâmetro (D). Neste trabalho utiliza-se como ferramenta o Processamento de Imagens digitais para o pré-diagnóstico do câncer de pele. / Skin cancer is one of the most frequent tumors . When early diagnosticated this kind of cancer reachs high percentage of cure. But the identification of its characteristics is necessary. The characteristics to be analised are: Asymmetry (A); Irregularity border (B); Color (C) and diameter (D). The present work uses as tool for first diagnostic of skin cancer the digital images processing.
357

A influência da espessura óssea na medição da altura da borda alveolar em imagens de tomografia computadorizada de feixe cônico e espiral / The influence of bone thickness in alveolar bone height measure in CBCT and MSCT

Renato Barcellos Rédua 29 February 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Imagens de tomografia computadorizada (TC) permitem a visualização, sem distorções ou sobreposições, do complexo maxilo-facial, principalmente do osso alveolar. Estudos demonstraram boa reprodutibilidade e precisão da mensuração da altura da borda alveolar, todavia a influência da espessura óssea ainda é pouco descrita. Através da comparação com a mensuração direta, o objetivo deste estudo foi avaliar a precisão, reprodutibilidade e a influência da espessura óssea, na mensuração da altura da borda alveolar em imagens volumétricas e imagens bidimensionais multiplanares em TC de feixe cônico (TCFC) e em TC espiral (TCE). Utilizando 10 mandíbulas secas de humanos, 57 dentes anteriores foram tomografados em equipamentos iCAT (Imaging Science International, Hatfield, PA, EUA) e Brilliance 64 canais (Philips Eletronics, Eindhoven, Holanda), ambos utilizando voxels de 0,25 mm. Através de imagens volumétricas (3D) e imagens bidimensionais (2D) de cortes multiplanares, foi comparada a mensuração da altura da borda alveolar dessas imagens com a mensuração direta nas mandíbulas, feita por vestibular e lingual, por três avaliadores, com o auxílio de um paquímetro, totalizando 114 bordas alveolares medidas. Alta reprodutibilidade intra-avaliador (0,999 a 0,902) e interavaliador (0,998 e 0,868) foi observada através do índice de correlação intraclasse (ICC). Observou-se alta correlação entre a mensuração direta e indireta da altura da borda alveolar em imagens 2D, sendo r=0,923** e 0,916**, e em imagens 3D, com r=0,929** e 0,954*, em TCFC e TCE, respectivamente. Imagens 2D superestimam a altura da borda alveolar em 0,32 e 0,49 mm e imagens 3D em 0,34 e 0,30 mm, em TCFC e TCE respectivamente. Quando o osso alveolar apresenta espessura de no mínimo 0,6 mm a média da diferença entre medidas diretas e indiretas é de 0,16 e 0,28 mm em imagens 2D e de 0,12 e 0,03 mm em imagens 3D para TCFC e TCE respectivamente, sendo que 95% do limite de concordância varia de -0,46 a 0,79 mm e -0,32 a 0,88 mm em imagens 2D, e de -0,64 a 0,67 mm e -0,57 a 0,62 mm em imagens 3D, para TCFC e TCE respectivamente. Quando o osso alveolar é mais fino do que 0,6 mm a TC é imprecisa, pois 95% do limite de concordância variou de -1,74 a 5,42 mm e -1,64 a 5,42 mm em imagens 2D, e de -3,70 a 4,28 mm e -3,49 a 4,25 mm em imagens 3D, para TCFC e TCE respectivamente. Conclui-se que a mensuração da altura da borda alveolar através de imagens tomográficas apresenta alta reprodutibilidade, sendo que quando a borda alveolar apresenta pelo menos 0,6 mm, a precisão da mensuração é alta, todavia quando esta espessura é menor do que 0,6 mm a técnica é imprecisa. / Computerized tomogoraphy (CT) images allow for visualization, with no distortions or superimpostions, of the maxillo-facial complex, especially of the alveolar margins. Studies have demonstrated good reproducibility and precision of the alveolar bone height, however the influence of bone thickness is still scarcely described. The purpose of this study was, by comparing the direct measurement of alveolar bone height, to evaluate the precision, reproducibility and the influence of bone thickness on the same measurement in cone beam CT (CBCT) and spiral CT (SCT) volumetric and biplane images. Ten dry human mandibles, with a total of 57 anterior teeth were tomographed with an iCAT (Imaging Science International, Hatfield, PA, EUA) and a 64 channels Brilliance 64 tomograph (Philips Eletronics, Eindhoven, Holland), both using voxels of 0.25 mm. Alveolar bone height was measured on volumetric (3D) and bidimensional (2D) images of tomograms and compared with direct caliper measurements performed on the dry mandibles, on the buccal and lingual sides, by three raters in a total of 114 measurements. High intra-rater (0.999 a 0.902) and inter-rater (0.998 e 0.868) reproducibility was observed using the intraclass correlation coefficient (ICC). A high correlation was also observed between the direct and indirect measurements of alveolar bone height in 2D (r=0.923** e 0.916**), and 3D images (r=0.929** e 0.954*), for CBCT and SCT, respectively. Two-dimensional images overestimate alveolar bone height in 0.32 and 0.49 mm and 3D images in 0.34 and 0.30 mm, for CBCT and SCT, respectively. When alveolar bone thickness is at least 0.6 mm the mean difference is of 0.16 and 0.28 mm in 2D images and of 0.12 and 0.03 mm in 3D images for CBCT and SCT, respectively, with 95% limits of agreement ranging from -0.46 to 0.79 mm and -0.32 to 0.88 mm in 2D images, and of -0.64 to 0.67 mm and -0.57 to 0.62 mm in 3D images, for CBCT and SCT, respectively. When alveolar bone thickness is smaller than 0.6 mm CT evaluation is inaccurate, since 95% limits of agreement vary from -1.74 to 5.42 mm and -1.64 to 5.42 mm in 2D images, and from -3.70 to 4.28 mm and -3.49 to 4.25 mm on 3D images, for CBCT and SCT, respectively. It can be concluded that measurement of alveolar bone height on CT images presents high reproducibility. When alveolar bone thickness is greater than 0.6 mm measurement precision is high, and when this thickness is less than 0.6 mm the technique is inaccurate
358

Avaliação dos aspectos morfológicos dos olhos normais e dos olhos com fechamento angular primário antes e após a realização da iridotomia: comparação através da gonioscopia, biometria e biomicroscopia ultra-sônica / Ultrasonographic biomicroscopy, conventional ultrasonography, and gonioscopy exams in normal and primary angle closure eyes before and after laser iridotomy

Lisandro Massanori Sakata 28 October 2005 (has links)
INTRODUÇÃO: O glaucoma de ângulo fechado é reconhecido como uma das principais causas de cegueira mundial. A iridotomia representa o tratamento de eleição nos casos com fechamento angular primário, entretanto, este procedimento pode não ser suficiente para proporcionar abertura do ângulo irido-corneano, controle da pressão intra-ocular (PIO) e estabilização do processo da lesão glaucomatosa. O presente estudo tem como objetivo avaliar a morfologia do segmento anterior do olho em uma amostra de pacientes brasileiros, e realizar uma comparação entre olhos normais (sem sinais de fechamento angular prévio) e olhos com ângulos oclusíveis, antes e após a realização da iridotomia. MÉTODOS: Realizou-se um estudo prospectivo observacional tipo caso-controle em pacientes da Clínica Oftalmológica do HC - FMUSP, onde 40 olhos com ângulos oclusíveis (grupo caso) e 27 olhos normais (grupo controle) foram examinados durante o período de agosto de 2003 a dezembro de 2004. Os pacientes do grupo controle foram pareados por idade, sexo e raça. Os exames de gonioscopia e biometria ultra-sônica foram utilizados para comparar os 27 olhos normais com os 40 olhos com ângulos oclusíveis, antes e após a realização da iridotomia. A biometria ultra-sônica mediu o comprimento axial do olho (CAX), a profundidade da câmara anterior (PCA) e o diâmetro ântero-posterior do cristalino (DAPC). Os 27 olhos do grupo controle foram comparados, através da biomicroscopia ultra-sônica, antes e após a iridotomia com os 31 olhos do grupo caso, que não apresentavam goniosinéquias no quadrante inferior. As imagens da UBM foram obtidas em cortes radiais sobre típicos processos ciliares, no claro e no escuro. A distância da abertura angular a 500?m do esporão escleral (DAA500), profundidade da câmara anterior (PCA-UBM), distância do trabeculado aos processos ciliares (DTPC), espessura da íris a 500?m do esporão escleral (EI500) e distância do esporão escleral à inserção da íris (linha X) foram medidas nas imagens da UBM obtidas às 6 horas. As freqüências de processos ciliares longos sem sulco ciliar e fechamento angular aposicional no escuro também foram determinadas nessas imagens. RESULTADOS: Os parâmetros morfológicos dos 27 olhos do grupo controle apresentaram diferenças significativas quando comparados com os 40 olhos do grupo caso. Os olhos normais apresentaram ângulo irido-corneano mais aberto, menor DAPC e maiores CAX e PCA. Nas imagens da UBM os 27 olhos normais apresentaram maior DAA500, PCA-UBM, linha X, e também, maior DTPC que os 31 olhos com ângulos oclusíveis (651 ± 119 ?m e 508 ± 116 ?m; p < 0.001); porém, a EI500 não apresentou diferença significativa entre os dois grupos. Após a realização da iridotomia foi observado uma abertura significativa do seio camerular, e uma diminuição da freqüência de fechamento angular aposicional nas imagens da UBM obtidas no escuro (28/31 para 16/31). Processos ciliares longos sem sulco ciliar foram observados em 61% (19/31) dos olhos do grupo caso após a iridotomia e em 33% (9/27) dos olhos do grupo controle. CONCLUSÃO: A presença de processos ciliares longos sem sulco ciliar foi um achado comum não somente nos olhos com ângulos oclusíveis como também nos olhos normais. No entanto, nos olhos do grupo caso, os processos ciliares estavam localizados, em média, numa posição mais anterior. Após a iridotomia, mais da metade dos olhos com ângulos oclusíveis continuaram apresentando fechamento angular aposicional na UBM. Os valores preditivos da presença de fechamento angular aposicional (associada ou não a processos ciliares longos sem sulco ciliar) na detecção de pacientes sob risco de apresentarem episódios de fechamento angular precisam ser avaliados em estudos futuros / Introduction: Angle closure glaucoma is emerging as one of the leading cause of worldwide blindness. Laser iridotomy (LI) has been proposed as first line therapy for patients with angle closure, however this procedure may not be effective opening the irido-corneal angle, controlling intra-ocular pressure (IOP) and halting glaucoma progression in all cases. Our study aimed to evaluate anterior segment morphology on a cohort of Brazilian patients comparing normal eyes (no signs of angle closure) to angle closure eyes before and after LI. Methods: In this prospective observational case control study, performed from August of 2003 to December of 2004, we evaluated 40 angle closure eyes and 27 normal control eyes with no signs of angle closure at clinical exam, paired by age, race and gender. We used gonioscopy and A-scan biometry to compare anterior segment morphology of 27 normal control eyes to 40 angle closure eyes of patients from our service, before and after LI. We also used ultrasound biomicroscopy (UBM) exam, to compare 27 normal control eyes to 31 of 40 angle closure eyes with no goniosynachiae at the inferior quadrant evaluated by gonioscopy, before and after LI. Immersion 50-MHz high-frequency ultrasound transducer was used to obtain UBM images in radial scans through a typical ciliary process, in both standard light and dark conditions. A-scan biometry measured axial length (AXL), anterior chamber depth (ACD) and lens thickness (LENS). The angle opening distance at 500?m from the scleral spur (AOD500), trabecular ciliary process distance (TCPD), iris thickness at 500?m and the distance from scleral spur to iris insertion (line X) were measured at UBM images obtained at the inferior quadrant. The frequency of appositional angle closure and the presence of long ciliary process with no ciliary sulcus were also evaluated at UBM images. Results: At gonioscopy and A-scan biometry exam, 27 normal eyes had a significant wider iridocorneal angle opening, a thinner LENS and a greater AXL, ACD than angle closure eyes. At UBM exam, 27 normal control eyes had an significant wider AOD500, line X and also, a longer TCPD than angle closure eyes (651 ± 119 ?m vs. 508 ± 116 ?m; p < 0.001); however no differences were observed in iris thickness between the two groups. After LI, we observed a significant irido-corneal angle opening and the number of angle closure eyes with UBM appositional angle closure in dark condition decreased from 28/31 to 16/31. A long ciliary processes with no ciliary sulcus were observed in 61% (19/31) of angle closure eyes after LI, and also in 33% (9/27) of normal control eyes. Conclusion: A long ciliary processes and absence of ciliary sulcus were a quite common finding not only in angle closure eyes, but also in normal control eyes. However, ciliary processes were located more anteriorly in angle closure eyes. On this cohort of Brazilian patients, more than half of studied eyes submitted to LI maintained UBM appositional angle closure. Whether this apposition with or without long ciliary process and absence of ciliary sulcus detected at UBM images after LI is associated to further goniosynachiae formation and/or loss of IOP control remains to be evaluated
359

Viabilidade do uso da termografia como recurso diagnóstico da fibromialgia / Viability of the use of thermography as a diagnostic resource for fibromyalgia

Oliveira, Lilian Danielle Cordeiro de 01 December 2017 (has links)
Introdução: A fibromialgia (FM) é uma condição crônica complexa caracterizada por dor generalizada, fadiga, sono não restaurador e comprometimento cognitivo, cuja prevalência na população em geral apresenta valores entre 0,2 e 6,6%. Não há marcadores biológicos, testes laboratoriais ou exames de imagem que validem a desordem, o que dificulta o diagnóstico. Objetivo: Verificar a viabilidade da utilização da termografia como recurso auxiliar no diagnóstico da fibromialgia. Métodos: Trata-se de um estudo descritivo transversal, onde foram avaliadas 14 mulheres de 24 a 66 anos, sendo 7 participantes do grupo FM e 7 do grupo controle (GC), sem a doença. Foram coletadas medidas de intensidade dolorosa, número de tender points (TP), máxima temperatura da pele em regiões de TP, avaliada por termografia e alteração morfofuncional no tórax por exame de ressonância magnética (RM). Resultados: Os grupos FM e GC apresentaram as maiores temperaturas cutâneas na região do tronco (vista anterior: SA01 e SA02; vista posterior: SP01 e SP02) e as menores temperaturas em membros inferiores (Vista anterior: IA01 e IA02; vista posterior: IP03 e IP04). A contagem de TP em ambos os grupos confirmou que a sintomatologia dolorosa é generalizada apenas no grupo FM. Neste grupo houve positividade nos 18 pontos para 4 participantes, sendo que 3 pontos foram identificados em todo o grupo (TPSA01, TPSA02 e TPSA03). Alterações morfofuncionais foram encontradas em ambos os grupos. Das quatro participantes com (FM) que realizaram a MRI, três apresentaram radiculopatias, enquanto que, para o GC, os três exames realizados apresentaram os mesmos achados. A termografia detectou a influência da adiposidade na captação das imagens para o GC sem doenças associadas, enquanto que para o grupo FM a adiposidade central e periférica não interferiu nos termogramas. Conclusão: Os resultados encontrados sugerem que, apesar da importância da utilização da termografia como recurso auxiliar no diagnóstico da fibromialgia, esta não apresentou capacidade para a interpretação isolada de sinais clínicos na análise conclusiva do diagnóstico. / Introduction: Fibromyalgia (FM) is a chronic complex condition characterized by generalized pain, weariness, non-restorative sleep and cognitive impairment, whose prevalence in the population represents values between 0,2 and 6,6%. There are no biological markers, laboratory tests or image exams that validate the disorder, which makes it difficult to diagnose. Objective: Check the viability of using thermography as auxiliar resourse in the diagnosis of fibromyalgia. Methods: It is a cross-sectional descriptive study, where 14 women aged 24 to 66 years were evaluated, being 7 participants of FM group and 7 of control group (CG), without the disease. Pain intensity measuarements were collected, number of tender points (TP), maximum skin temperature in TP regions, evaluated by thermography and morphofunctional change in the thorax by magnetic resonance imaging (MRI). Results: The groups FM and GC show the biggest skin temperatures in the trunk region (upper view: SA01 and SA02; bottom view SP01 and SP02) and the lowest temperatures in lower members (upper view: IA01 and IA02; bottom view: IP03 and IP04). The count of TP in both groups confirmed that the pain symptomatology is generalized only in FM group. In this group, there was positivity in the 18 points for 4 participants, with 3 points identified in the whole group (TPSA01, TPSA02 and TPSA03). Morphofunctional changes were found in both groups. Of the 4 participants with (FM) that performed MRI, 3 had radiculopathies, while for the GC, the 3 exams performed presented the same results. The thermography detected the influence of adiposity on the capture of images for GC without associated diseases, while for FM group the central and peripheral adiposity did not interfere in thermograms. Conclusion: The results suggest that, despite the importance of using thermography as auxiliary resourse in fibromyalgia diagnosis, it did not have the capacity for the isolated interpretation of clinical signals in the conclusive analysis of the diagnosis.
360

Qualidade da imagem, limiar de contraste e dose glandular média em mamografia digital CR

Jakubiak, Rosangela Requi 30 January 2013 (has links)
Em muitos países, os sistemas de radiologia computadorizada (CR) representam a maioria dos equipamentos usados em mamografia digital. Este estudo apresenta um método para a otimização da qualidade da imagem e da dose em mamografia digital CR para pacientes com mamas de espessuras entre 45 e 75. As espessuras das mamas foram simuladas com placas de polimetilmetacrilato (PMMA). Técnicas de exposição otimizadas (tensão (kV), produto corrente-tempo (mAs) e combinação alvo/filtro) foram definidas como aquelas que fornecem uma razão contraste-ruído (CNR) ideal, denominada CNR alvo, que permite atingir o limiar de contraste das imagens do detalhe de diâmetro de 0,10 mm no simulador CDMAM (versão 3.4 Artinis Medical Systems, Netherlands) com um padrão de Dose Glandular Média (DGM) aceitável. Os resultados foram utilizados para os ajustes do Controle Automático de Exposição (CAE) pela equipe de manutenção. Um estudo retrospectivo de dois grupos de pacientes (Grupo 1-antes do ajuste do CAE e Grupo 2- após o ajuste do CAE) foi realizado. Os parâmetros de exposição foram reproduzidos nos simuladores para a determinação da CNR, da DGM e do limiar de contraste. As imagens clínicas destes pacientes foram analisadas por três radiologistas especialistas em mamografia que responderam questões sobre as estruturas anatômicas, ruído e contraste em áreas de valores de pixels altos ou baixos, sobre nitidez e contraste da imagem. Os resultados mostram que o método proposto foi efetivo para todas as espessuras de mama avaliadas. O ajuste do CAE proporcionou a concentração de valores da CNR no Grupo 2 mais próximas ao CNR alvo e que, mesmo como aumento do nível de ruído nas imagens clínicas, as análises do CDMAM mostraram que não houve prejuízo na identificação do objeto de 0,10 mm de diâmetro. Finalmente, este estudo conclui que o uso dos CAE das unidades de raios X baseados em fornecer uma dose constante ao detector pode ocasionar algumas dificuldades para alguns sistemas CR operarem nas condições ótimas. / In many countries, computed radiography (CR) systems represent the majority of equipments used in digital mammography. This study presents a method for optimizing image quality and dose in CR mammography of patients with breast thicknesses between 45 to 75mm. The breast thicknesses were simulated with polymethylmetacrylate (PMMA). Optimazed exposure parameters ((voltage (kV), mA and time product (mAs) and target/filter combination)) was defined as giving an ideal contrast to noise ratio (CNR), defined as target CNR, to reach the threshold contrast of CDMAM (version 3.4) phantom (Artinis Medical Systems, Netherlands) images for acceptable mean glandular dose (MGD). These results were used for adjustments in the automatic exposure control (AEC) by the maintenance team. A retrospective study of two groups of patients (Group 1-before AEC adjustment and Group 2- after AEC adjustment) were done. The exposure parameters were reproduced in the phantoms to determine of CNR, MGD and threshold contrast. The clinical images of these patients were analyzed by three experienced radiologists who answered questions about anatomical structures, noise and contrast in low and high pixel value areas and image sharpness and contrast. The results showed that the proposed method was effective for all breast thickness evaluated. The AEC adjustment showed a concentration of CNR in Group 2 nearer of target CNR, and that the increasing of noise in clinical images, the CDMAM analysis showed that this level of noise did not disturb the detail of 0,1 mm diameter. Finally, this study also concluded that the use AEC of X rays unit based on constant dose to the detector may bring some difficulties to CR systems operate in optimal conditions.

Page generated in 0.0627 seconds