• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 3
  • 3
  • Tagged with
  • 18
  • 18
  • 6
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Diffraction Tomographic Imaging With A Circular Array

Vasuki, A 10 1900 (has links)
In the conventional diffraction tomography a linear array is used to receive forward scattered field. Then a standard algorithm like back propagation or Fourier domain interpolation is used for reconstruction of the object. A circular array which captures both forward and backward scattered field has been proposed. A new theorem is proposed, which states that the scattered field measured with a large circular array surrounding the object is proportional to the Fourier transform of the object profile taken on the circumference of a circle of radius equa1 to the wave number and centered at (-k0 cosZO, -k0 sin Z0). The circular array outperforms in two counts. Firstly, a larger bandwidth of Fourier transform is used for reconstruction. Secondly, in circular array since the scattered field itself is related to the object Fourier transform, the reconstruction is free from the errors induced by finite array size. The effect of broad band illumination has been studied. A fewer number of illuminations appear to produce a reconstruction which is possible only with a large number of illuminations but narrow band illumination. Thus a trade off between the number of illumination angles and the bandwidth of the source exists.
2

Optical Diffraction Tomography for the Refractive Index Profiling of Objects with Large Space-Bandwidth product

John, Jem Teresa January 2017 (has links) (PDF)
The primary goal of this work is to arrive at direction tomography (DT) algorithms freed from the severe linearization in the formulation, and as-assumptions on variation of the refractive index distribution (RID), involved in the earlier approaches based on Born and Royton approximations and the Fourier di reaction theorem (FDT). To start with, a direct single-step re-covery of RID from intensity measurements is demonstrated, replacing the common two-step procedure involving, rest the recovery of phase from in-density followed by the inversion of scattered led for the RID. The information loss, unavoidable in a two-step procedure is thus successfully addressed. Secondly, an iterative method which works with a forward model obtained directly from the Helmholtz equation is developed. This forward model, though has simplifying assumptions, is more general and can accommodate larger variations in RID than that allowed in the previous linear models. The iterative procedure has an update step which uses a linearization of the forward model and a re-linearization step at the updated RID. The procedure which directly employs the measured intensities is used as part of a deterministic Gauss-Newton algorithm and a stochastic optimization algorithm which uses the ensemble Kalman lter to arrive at the recursive update. The stochastic method is found to be more noise-tolerant and efficient to take care of process model inaccuracies. The proof is seen in better reconstructions from experimental data for two example objects, namely, a graded-index optical bre and a photonic-crystal bre. It is further ob-served that the reconstructions from photonic crystal bre are blurred, noisy and less accurate. Identifying the inaccurate implementation of the modemed Helmholtz equation for large k values employing the current sampling rate as the shortcoming, a new procedure, which splits the bandwidth into smaller components using short-time Fourier Transform is developed. The set of equations arrived at, each t for a narrow frequency band, is solved and the solutions are reassembled to obtain the scattered led for the original problem. The simulated di rated intensities so obtained are better matched to their measured experimental counterparts. However, the impel-mentation of the mode end procedure is computation-intensive, for which a parallel-processing machine can be a good solution. The recovery of RID with this mode cation is not attempted in this work and is left for future implementation.
3

Avaliação de métodos de tomografia por ondas guiadas para mapeamento de dano por corrosão localizada

Dorneles, Lucas da Luz January 2016 (has links)
Sistemas de ensaios não destrutivos por ondas guiadas despertam cada vez mais a atenção tanto da indústria, como da academia. Isso deve-se, principalmente, às possibilidades que as ondas guiadas permitem, como maior área de triagem que o ultrassom convencional. Porém a técnica tem suas limitações, já que esta apenas gera uma estimativa da localização de um defeito e não a sua dimensão. Nessa limitação, algoritmos tomográficos apresentam uma possibilidade de avanço da técnica, pois permitem determinar não só a localização de corrosões e defeitos, mas também seu dimensionamento. Este trabalho apresenta tomografia de difração como uma alternativa para avaliação de integridade estrutural. Primeiramente, utilizou-se análise por métodos numéricos para mostrar a validade dos algoritmos e posteriormente foi realizado um experimento em uma chapa real com o objetivo de reconstruir a imagem do defeito. / Guided waves nondestructive testing systems are increasingly attracting industrial and academic attention. The mainly reason for this attention is the possibility of screening a large area than conventional ultrasound technique. However, Guided Waves Testing has limitations, since it gives only an estimation of the location of a defect, but not the dimensions. Tomographic algorithms come up with an improvement of the technique, because it allows discovery not only the location of corrosions and defects, but the dimensions too. This work brings Diffraction Tomography as an alternative to structural health monitoring. First, a numerical analysis was implemented to demonstrate the validity of the algorithms, after that an experiment in a real plate was made with the objective to recover the defect image.
4

Avaliação de métodos de tomografia por ondas guiadas para mapeamento de dano por corrosão localizada

Dorneles, Lucas da Luz January 2016 (has links)
Sistemas de ensaios não destrutivos por ondas guiadas despertam cada vez mais a atenção tanto da indústria, como da academia. Isso deve-se, principalmente, às possibilidades que as ondas guiadas permitem, como maior área de triagem que o ultrassom convencional. Porém a técnica tem suas limitações, já que esta apenas gera uma estimativa da localização de um defeito e não a sua dimensão. Nessa limitação, algoritmos tomográficos apresentam uma possibilidade de avanço da técnica, pois permitem determinar não só a localização de corrosões e defeitos, mas também seu dimensionamento. Este trabalho apresenta tomografia de difração como uma alternativa para avaliação de integridade estrutural. Primeiramente, utilizou-se análise por métodos numéricos para mostrar a validade dos algoritmos e posteriormente foi realizado um experimento em uma chapa real com o objetivo de reconstruir a imagem do defeito. / Guided waves nondestructive testing systems are increasingly attracting industrial and academic attention. The mainly reason for this attention is the possibility of screening a large area than conventional ultrasound technique. However, Guided Waves Testing has limitations, since it gives only an estimation of the location of a defect, but not the dimensions. Tomographic algorithms come up with an improvement of the technique, because it allows discovery not only the location of corrosions and defects, but the dimensions too. This work brings Diffraction Tomography as an alternative to structural health monitoring. First, a numerical analysis was implemented to demonstrate the validity of the algorithms, after that an experiment in a real plate was made with the objective to recover the defect image.
5

Avaliação de métodos de tomografia por ondas guiadas para mapeamento de dano por corrosão localizada

Dorneles, Lucas da Luz January 2016 (has links)
Sistemas de ensaios não destrutivos por ondas guiadas despertam cada vez mais a atenção tanto da indústria, como da academia. Isso deve-se, principalmente, às possibilidades que as ondas guiadas permitem, como maior área de triagem que o ultrassom convencional. Porém a técnica tem suas limitações, já que esta apenas gera uma estimativa da localização de um defeito e não a sua dimensão. Nessa limitação, algoritmos tomográficos apresentam uma possibilidade de avanço da técnica, pois permitem determinar não só a localização de corrosões e defeitos, mas também seu dimensionamento. Este trabalho apresenta tomografia de difração como uma alternativa para avaliação de integridade estrutural. Primeiramente, utilizou-se análise por métodos numéricos para mostrar a validade dos algoritmos e posteriormente foi realizado um experimento em uma chapa real com o objetivo de reconstruir a imagem do defeito. / Guided waves nondestructive testing systems are increasingly attracting industrial and academic attention. The mainly reason for this attention is the possibility of screening a large area than conventional ultrasound technique. However, Guided Waves Testing has limitations, since it gives only an estimation of the location of a defect, but not the dimensions. Tomographic algorithms come up with an improvement of the technique, because it allows discovery not only the location of corrosions and defects, but the dimensions too. This work brings Diffraction Tomography as an alternative to structural health monitoring. First, a numerical analysis was implemented to demonstrate the validity of the algorithms, after that an experiment in a real plate was made with the objective to recover the defect image.
6

Studies On Wavefront Estimation And Refraction Corrected Image Reconstruction In Optical Tomography

Datta, G Keshava 04 1900 (has links) (PDF)
No description available.
7

Inverse Scattering Image Quality with Noisy Forward Data

Sorensen, Thomas J. 15 July 2008 (has links) (PDF)
Image quality metrics for several inverse scattering methods and algorithms are presented. Analytical estimates and numerical simulations provide a basis for poor image quality diagnostics. The limitations and noise behavior of reconstructed images are explored analytically and empirically using a contrast ratio. Theoretical contrast ratio estimates using the canonical PEC circular cylinder are derived. Empirical studies are conducted to confirm theoretical estimates and to provide examples of image quality vs SNR for more complex scatterer profiles. Regularized sampling is shown to be more noise sensitive than tomographic reconstructive methods.
8

DESIGN OF A LOW PROFILE CONFORMAL ARRAY FOR TRANSCRANIALULTRASOUND IMAGING

Smiley, Aref 17 May 2018 (has links)
No description available.
9

Diffraction Tomographic Imaging of Shallowly Buried Targets using Ground Penetrating Radar

Hislop, Gregory Francis January 2005 (has links)
The problem of subsurface imaging with Ground Penetrating Radar (GPR) is a challenging one. Due to the low-pass nature of soil sensors must utilise wave-lengths that are of the same order of magnitude as the object being imaged. This makes imaging difficult as straight ray approximations commonly used in higher frequency applications cannot be used. The problem becomes even more challenging when the target is shallowly buried as in this case the ground surface reflection and the near-field parameters of the radar need to be considered. This thesis has investigated the problem of imaging shallowly buried targets with GPR. Two distinct problems exist in this field radar design and the design of inverse scattering techniques. This thesis focuses on the design of inverse scattering techniques capable of taking the electric field measurements from the receiver and providing accurate images of the scatterer in real time. The thesis commences with a brief introduction to GPR theory. It then provides an extensive review of linear inverse scattering techniques applied to raw GPR data. As a result of this review the thesis draws the conclusion that, due to its strong foundations in Maxwell's equations, diffraction tomography is the most appropriate approach for imaging shallowly buried targets with GPR. A three-dimensional diffraction tomographic technique is then developed. This algorithm forms the primary contribution of the thesis. The novel diffraction tomography technique improves on its predecessors by catering for shallowly buried targets, significant antenna heights and evanescent waves. This is also the first diffraction tomography technique to be derived for a range of antenna structures. The advantages of the novel technique are demonstrated first mathematically then on synthetic and finally practical data. The algorithm is shown to be of high practical value by producing accurate images of buried targets in real time.
10

Novel Applications of Optical Diffraction Tomography: On-chip Microscopy and Detection of Invisibility Cloaks

Díaz Fernández, Francisco Javier 21 January 2022 (has links)
[ES] La tomografía por difracción surge para mejorar las técnicas de imagen al considerar la naturaleza ondulatoria de la luz. Mientras que los primeros sistemas de imagen médica se basaban únicamente en fuentes sin difracción, este enfoque consigue mejorar la reconstrucción del índice de refracción de los objetos, lo que permite, por ejemplo, el estudio de estructuras subcelulares. Del mismo modo, la demanda de redes de telecomunicaciones cada vez más rápidas y seguras ha propiciado la aparición de la fotónica. Hace dos décadas, la combinación de estos dos campos dio lugar a los primeros sistemas de tomografía por difracción óptica (ODT), los cuáles han evolucionado rápidamente durante este siglo. En esta tesis, presentamos dos nuevas aplicaciones de la ODT. La primera está relacionada con el concepto del microscopio tomográfico de fase (TPM), una versión de la ODT que permite el estudio de células aisladas, con muchas aplicaciones biomédicas, como el diagnóstico y la prognosis del cáncer. Sin embargo, los sistemas TPM actuales son caros, pesados y complejos. Para resolver estos problemas, proponemos el concepto de TPM en chip. Con este fin, diseñamos una hoja de ruta hacia el primer dispositivo tomográfico integrado en el marco de la tecnología lab-on-a-chip (LoC), y desarrollamos los primeros pasos para ello: 1) Hasta ahora, sólo se han utilizado detectores planos para obtener los mapas de índice de refracción de los objetos estudiados en TPM, basados en la detección del campo difractado hacia delante. Sin embargo, los principios físicos fundamentales indican que medir también el campo difractado hacia detrás debería mejorar la resolución de las imágenes. Además, un detector plano no es la configuración óptima para el TPM en chip. En esta línea, hemos explorado la posibilidad de usar detectores circulares en este escenario, como una técnica más adecuada para las configuraciones en chip, demostrando al mismo tiempo que este enfoque proporciona una mejor resolución que el lineal. 2) Proponemos un esquema de TPM en chip basado en el uso de nanoantenas dieléctricas como fuente de luz y píxeles detectores ODT, y caracterizamos experimentalmente su comportamiento mediante microscopía óptica de campo cercano. En cuanto a la segunda aplicación, estudiamos el potencial de la ODT como nuevo paradigma en la detección de capas de invisibilidad realistas, una de las aplicaciones más importantes de los metamateriales. Hasta ahora, el scattering cross section (SCS) se ha utilizado como modelo de referencia para diseñar y observar la eficacia de estos dispositivos para ocultar objetos. En nuestro estudio, demostramos que la ODT puede detectar las capas de invisibilidad prácticas con una sensibilidad superior a la que ofrece el SCS, incluso a las frecuencias de trabajo óptimas. Además, es posible obtener una imagen representativa del tamaño y la forma de la capa, revelando claramente su existencia. Finalmente, se discuten las conclusiones extraídas de los resultados obtenidos. Además, se detallan las futuras líneas de trabajo para abordar los retos que no se han completado en esta tesis doctoral. / [CA] La tomografia per difracció sorgeix per millorar les tècniques d'imatge anteriors en considerar la naturalesa ondulatòria de la llum. Mentre que els primers sistemes d'imatge mèdica es basaven únicament en fonts sense difracció, aquest enfocament aconsegueix millorar la reconstrucció de l'índex de refracció dels objectes, la qual cosa permet, per exemple, l'estudi d'estructures subcelulars. De la mateixa manera, la demanda de xarxes de telecomunicacions cada vegada més ràpides i segures ha propiciat l'aparició de la fotònica. Fa dues dècades, la combinació d'aquests dos camps va portar als primers sistemes de tomografia per difracció òptica (ODT), els quals han evolucionat ràpidament durant aquest segle. En aquesta tesi, presentem dues noves aplicacions de la ODT. La primera està relacionada amb el concepte del microscopi tomogràfic de fase (TPM), una versió de la ODT que permet l'estudi de cèl·lules aïllades, amb moltes aplicacions en biomedicina, com el diagnòstic i prognosi del càncer. No obstant això, els sistemes TPM actuals són cars, pesats i complexos. Per resoldre aquests problemes, proposem el concepte de TPM en xip. Per fer-ho, dissenyem un full de ruta cap al primer dispositiu tomogràfic integrat en el marc de la tecnologia lab-on-a-chip (LoC), i desenvolupem els primers passos a aquest efecte: 1) Fins ara, només s'han utilitzat detectors plans per a obtindre els mapes d'índex de refracció dels objectes estudiats en TPM, basats en la detecció del camp difractat cap avant. No obstant això, els principis físics fonamentals indiquen que mesurar també el camp difractat cap endarrere hauria de millorar la resolució de les imatges. A més, un detector pla no és la configuració òptima per al TPM en xip. En aquesta línia, hem explorat la possibilitat d'usar detectors circulars en aquest escenari, com una tècnica més adequada per a les configuracions en xip, demostrant al mateix temps que aquest enfocament proporciona una millor resolució que el lineal. 2) Proposem un esquema de TPM en xip basat en l'ús de nanoantenes dielèctriques com a font de llum i píxels detectors ODT, i caracteritzem experimentalment el seu comportament en camp pròxim mitjançant microscòpia òptica de camp pròxim. Pel que fa a la segona aplicació, estudiem el potencial de la ODT com a nou paradigma en la detecció de capes d'invisibilitat realistes, una de les aplicacions més importants dels metamaterials. Fins ara, el scattering cross section (SCS) s'ha utilitzat com a model de referència per a dissenyar i observar l'eficàcia d'aquests dispositius per a ocultar objectes. En el nostre estudi, vam demostrar que la ODT pot detectar les capes d'invisibilitat pràctiques amb una sensibilitat superior a la que ofereix el SCS, fins i tot a les freqüències de treball òptimes. A més, és possible obtindre una imatge representativa de la grandària i la forma de la capa, revelant clarament la seua existència. Finalment, es discuteixen les conclusions extretes dels resultats obtinguts i es detallen les futures línies de treball per a abordar els reptes que no s'han completat en aquesta tesi doctoral. / [EN] Diffraction Tomography arises to improve previous imaging techniques by considering the wave nature of light. Whereas the first medical imaging systems relied only on non-diffracting sources, this approach results in an enhanced reconstruction of the object's refractive index distribution, allowing, for example, the study of subcellular structures. Likewise, the demand for increasingly faster and secure telecommunication networks led to the advent of photonics. Two decades ago, the combination of these two fields gave rise to the first optical diffraction tomography (ODT) systems, which have rapidly evolved during this century. In this thesis, we present two novel applications of ODT. The first one is related to the concept of tomographic phase microscopy (TPM), a version of ODT that enables the study of isolated cells, with many applications in biomedicine, such as the diagnosis and prognosis of cancer. Nevertheless, current TPM systems are expensive, heavy, and cumbersome. To solve these issues we propose the concept of on-chip TPM. For this purpose, we design a roadmap towards the first integrated tomographic device in the frame of lab-on-a-chip (LoC) technology and develop the first steps to this end: 1) Until now, only flat detectors have been used to obtain the refractive index maps of the objects studied in TPM, based on the detection of the forward scattering. However, fundamental physical principles indicate that measuring also the backscattered field should improve the resolution of the images. Moreover, a flat detector is not the optimal configuration for on-chip TPM. In this vein, we have explored the possibility of using circular detectors in this scenario as a more suitable technique for on-chip configurations, demonstrating at the same time that this approach provides a better resolution than the linear one. 2) We propose a TPM on-chip scheme based on the use of dielectric nanoantennas as the ODT light source and detector pixels, and experimentally characterize their near-field behavior via scanning near-field optical microscopy. As for the second application, we study the potential of ODT as a new paradigm in the detection of realistic invisibility cloaks, one of the most important applications of metamaterials. Up to now, the scattering cross section (SCS) has been used as the gold standard to design and observe the effectiveness of these devices in hiding objects. In our study, we show that ODT can detect practical invisibility cloaks with a higher sensitivity than that offered by the SCS, even at the optimal working frequencies. Moreover, it is possible to obtain an image depicting the size and shape of the cloak, clearly revealing their existence. Finally, the conclusions drawn from the obtained results are discussed. In addition, future lines of action to address the challenges that have not been completed in this doctoral thesis are detailed. / Díaz Fernández, FJ. (2021). Novel Applications of Optical Diffraction Tomography: On-chip Microscopy and Detection of Invisibility Cloaks [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/180125

Page generated in 0.1138 seconds