• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • 1
  • Tagged with
  • 10
  • 10
  • 10
  • 8
  • 8
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Aplicações da informação genômica no estudo de populações selecionadas /

Maiorano, Amanda Marchi. January 2019 (has links)
Orientador: Josineudson Augusto II de Vasconcelos Silva / Coorientador: Daniela Andressa Lino Lourenço / Coorientador: Joslaine Noely dos Santos Gonçalves Cyrillo / Banca: Danísio Prado Munari / Banca: Nedênia Bonvino Stafuzza / Banca: Rusbel Raul Aspilcueta Borquis / Resumo: A disponibilidade de painéis de polimorfismos de nucleotídeos únicos (SNPs) a baixo custo tem viabilizado estudos genômicos em espécies de interesse econômico. Os objetivos do presente estudo foram conduzir análises de estruturação da população e assinaturas de seleção em duas populações de bovinos Gir selecionadas para diferentes critérios de seleção (corte ou leite); e investigar se a estimativa do efeito materno para característica medida na progênie apresenta maior acurácia com uso de "pool" de sêmen e informação genômica em diferentes cenários simulados de suínos. Análise de componentes principais (PCA) e Análise Discriminante de Componentes Principais (DAPC) foram utilizadas para verificar a estrutura da população nas populações Gir analisadas, e três métodos diferentes foram utilizados na detecção de assinaturas de seleção: índice de fixação (Fst), Escore de Integração dos Haplótipos (iHS) e Homozigose do Haplótipo Estendido Entre Populações (XP-EHH). Diferenciação genética entre as duas populações de bovinos foi observada nos resultados de PCA e DAPC. Um total de 282 genes foram identificados sob seleção, com base nos testes Fst, iHS e XP-EHH, dos quais 35 genes estão associados com QTL previamente descritos em bovinos. Os padrões de variação genética nos bovinos Gir foram consistentes com a presença de pressões seletivas em algum momento na história das populações de corte e leite. Estes resultados fornecem informações complementares sobre regiões genômicas de intere... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The availability of commercial SNP panels at a low cost has made it possible the application of genomic studies in domestic species. The aim of this study was to conduct population structure and signatures of selection analyzes in two populations of Gir cattle selected for different criteria (beef or dairy); and to investigate whether maternal direct effect for litter birth weight can be improved when pooled semen and genomic information are used in different simulated scenarios in pigs. Principal Component Analysis (PCA) and Discriminant Analysis of Principal Components (DAPC) were used to verify population structure in the studied Gir cattle populations, and three different methods were used to detect signatures of selection: fixation index (Fst), Integrated Haplotype Score (iHS), and Cross-Population Extend Haplotype Homozygosity (XP-EHH). Genetic differentiation between the two cattle populations was observed in the PCA and DAPC results. A total of 282 genes were identified under selection based on the Fst, iHS and XP-EHH tests, of which 35 genes are associated with QTL previously described in cattle. The patterns of genotypic variation in Gir cattle were consistent with the presence of selective pressures at some point in the history of the beef and dairy populations. These findings can provide complementary information on genomic regions of interest for functional genomic studies, genome-wide associations, and the implementation of breeding schemes aiming genetic improv... (Complete abstract click electronic access below) / Doutor
2

Acurácia de diferentes indicadores eletrocardiográficos na detecção de hipertrofia ventricular esquerda em pacientes hipertensos

Gonçalves, Renato de Souza [UNESP] 10 May 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-05-10Bitstream added on 2014-06-13T19:02:36Z : No. of bitstreams: 1 goncalves_rs_dr_botfm.pdf: 1301205 bytes, checksum: e3b3c0f2b675654eacec3e3870a2e77c (MD5) / A utilização de índices eletrocardiográficos que associam a duração do QRS e do tempo de ativação ventricular melhorou a sensibilidade do exame no diagnóstico de hipertrofia ventricular esquerda, sobretudo em pacientes com doença arterial coronariana. Em pacientes com hipertensão arterial sistêmica as informações são escassas. Os objetivos deste estudo foram: avaliar a acurácia de critério que usa a duração do QRS e o tempo de ativação ventricular para detectar hipertrofia ventricular esquerda; comparar essa acurácia com critérios utilizados na prática médica; verificar quais variáveis clínicas se associam com modificações da acurácia do eletrocardiograma. O estudo foi retrospectivo, incluindo pacientes hipertensos assintomáticos, cadastrados de forma consecutiva nos ambulatórios de atendimento primário de hipertensão arterial do Hospital das Clínicas da Faculdade de Medicina de Botucatu, que realizaram eletrocardiograma e ecocardiograma no mesmo dia, no período entre 2004 e 2006 para detecção de hipertrofia ventricular esquerda. Foram excluídos: portadores de valvopatia, cardiopatia congênita, infarto do miocárdio e insuficiência cardíaca, os que apresentassem no eletrocardiograma bloqueio do ramo direito, bloqueio do ramo esquerdo, fibrilação atrial, pré-excitação ventricular, ritmo de marcapasso e áreas eletricamente inativas, pacientes com fração de ejeção menor que 0,50 no ecocardiograma. Os critérios eletrocardiográficos foram: Sokolow-Lyon, Cornell, Framingham, Cornell-strain, critério de massa pelo eletrocardiograma indexada a superfície corpórea (ImECG), escore de Romhilt-Estes e de Perugia. O eletrocardiograma foi analisado por médico experiente que não conhecia o resultado do ecocardiograma. A massa ventricular esquerda indexada pela superfície corpórea, detectada ao ecocardiograma... / not available
3

Acurácia de diferentes indicadores eletrocardiográficos na detecção de hipertrofia ventricular esquerda em pacientes hipertensos /

Gonçalves, Renato de Souza. January 2013 (has links)
Orientador: Beatriz Bojikian Matsubara / Coorientador: Luis Cuadrado Martin / Banca: João CArlos Hueb / Banca: Roberto Jorge da Silva Franco / Banca: Fábio Villaça Guimarães Filho / Banca: Alexandre Rodrigues / Resumo: A utilização de índices eletrocardiográficos que associam a duração do QRS e do tempo de ativação ventricular melhorou a sensibilidade do exame no diagnóstico de hipertrofia ventricular esquerda, sobretudo em pacientes com doença arterial coronariana. Em pacientes com hipertensão arterial sistêmica as informações são escassas. Os objetivos deste estudo foram: avaliar a acurácia de critério que usa a duração do QRS e o tempo de ativação ventricular para detectar hipertrofia ventricular esquerda; comparar essa acurácia com critérios utilizados na prática médica; verificar quais variáveis clínicas se associam com modificações da acurácia do eletrocardiograma. O estudo foi retrospectivo, incluindo pacientes hipertensos assintomáticos, cadastrados de forma consecutiva nos ambulatórios de atendimento primário de hipertensão arterial do Hospital das Clínicas da Faculdade de Medicina de Botucatu, que realizaram eletrocardiograma e ecocardiograma no mesmo dia, no período entre 2004 e 2006 para detecção de hipertrofia ventricular esquerda. Foram excluídos: portadores de valvopatia, cardiopatia congênita, infarto do miocárdio e insuficiência cardíaca, os que apresentassem no eletrocardiograma bloqueio do ramo direito, bloqueio do ramo esquerdo, fibrilação atrial, pré-excitação ventricular, ritmo de marcapasso e áreas eletricamente inativas, pacientes com fração de ejeção menor que 0,50 no ecocardiograma. Os critérios eletrocardiográficos foram: Sokolow-Lyon, Cornell, Framingham, Cornell-strain, critério de massa pelo eletrocardiograma indexada a superfície corpórea (ImECG), escore de Romhilt-Estes e de Perugia. O eletrocardiograma foi analisado por médico experiente que não conhecia o resultado do ecocardiograma. A massa ventricular esquerda indexada pela superfície corpórea, detectada ao ecocardiograma... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: not available / Doutor
4

Mensuração da alteração dimensional de uma silicona por condensação através de três métodos distintos / The dimensional change measurement of a silicone condensation trhough three different methods

Cunha, Thaiana Damaceno 27 April 2015 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2015-12-04T14:43:43Z No. of bitstreams: 1 thaianadamacenocunha.pdf: 1265962 bytes, checksum: 6d8fb90304d78d671faf48a4a00e64e5 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2015-12-07T03:22:42Z (GMT) No. of bitstreams: 1 thaianadamacenocunha.pdf: 1265962 bytes, checksum: 6d8fb90304d78d671faf48a4a00e64e5 (MD5) / Made available in DSpace on 2015-12-07T03:22:42Z (GMT). No. of bitstreams: 1 thaianadamacenocunha.pdf: 1265962 bytes, checksum: 6d8fb90304d78d671faf48a4a00e64e5 (MD5) Previous issue date: 2015-04-27 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste estudo foi mensurar a alteração dimensional de uma silicona por condensação através de um paquímetro digital (Mitutuyo), de um estéreo microscópio (Olympus) e de uma máquina de medição tridimensional por coordenadas (Mitutuyo). Foram realizadas 4 moldagens através de um dispositivo específico com a silicona por condensação pesada e leve Speedex (Coltene/Vigodent). Em cada um dos 4 moldes 4 distâncias foram mensuradas pelos 3 instrumentos, em 4 tempos distintos: no momento da remoção do molde e após 30min, 1h e 7 dias. As médias das mensurações foram submetidas ao teste estatístico Kruskal-Wallis com nível de significância de 5%. Os resultados mostraram diferenças significantes entre as alterações dimensionais verificadas por cada um dos instrumentos de medição, as mensurações realizadas pelo paquímetro digital e pela máquina de medição tridimensional por coordenadas apresentaram alterações dimensionais significantes nos 4 tempos testados, enquanto as pelo estéreo microscópio não apresentaram diferença significante nos 4 tempos. Concluiu-se que as alterações dimensionais verificadas nos moldes da silicona por condensação testada obtidas através de cada instrumento de medição utilizado nesta pesquisa foram diferentes entre si, evidenciando que os diferentes métodos de medição utilizados podem fornecer resultados distintos, e consequentemente, indicações equivocadas. / The aim of this study was to measure the dimensional changes of a silicone condensation using a digital paquimeter (Mitutuyo), an estereomicroscope (Olympus) and a three-dimensional coordinate measuring machine (Mitutuyo). Were made 4 impressions trhough a specif device using the putty and light silicone condensation Speedex (Coltene/Vigodent). Four distances were measured at each impression through the 3 instruments at 4 different times: in the moment of removal of the die and after 30min, 1h e 7 days. The avarage of the measurements were subimitted to the statistical test Kruskal-Wallis with level of significance of 5%. The results shows significant diferences between the dimensional changes verified by each one of the measuring instruments, the measurements through the digital paquimeter and the measurements trhough the three-dimensional coordinate measuring machine showed significant dimensional changes in the 4 tested times, while the measurements through the estereomicroscope did not show significant difference in the 4 tested times. It concludes that the dimensional changes verified in the tested silicone condensation by each measurement instrument used in this study were diferente, indicating that the different measuring methods used can provide wrong results, and consequently, wrong indications.
5

A standardized method for evaluating trueness and precision of intraoral scanners – in vitro accuracy

Gashi, Tomor, Larsson, Eddie January 2014 (has links)
Bakgrund. En gyllene standard för att bestämma noggrannheten för intraorala scannrarexisterar inte. Intraorala scannrars prestanda som ges av olika leverantörer är inte fulltjämförbara. Det finns ett behov att standardisera och ta fram oberoende försöksupplägg för att kunna jämföra intraorala scannrar.Mål. Målet med studien var att beskriva och utvärdera en ny metod för att bestämmanoggrannheten av intraorala scannrar genom ett standardiserat in vitro testförsök och attanvända metoden för att beräkna noggrannheten på en kommersiell intraoral scanner.Material och metod. SP Sveriges tekniska forskningsinstitut definierade dimensionerna avett sfäriskt testobjekt. Sfären besprutades med titanoxid och skannades 12 gånger med enkommersiell intraoral scanner. Scanningarna utvärderades med två metoder. Manuell metod: sfärens diameter uppmättes 12 gånger i ett första mjukvaruprogram för varje scanning genom att justera ett tvärsnittsplan. Automatisk metod: 12 nominella diametrar beräknades från ett andra mjukvaruprogram. Noggrannheten beräknades för varje testmetod och jämfördes.Resultat. Referensmätning: den definierade diameter var 4,9991±0,0001mm. Manuell metod: riktigheten var 25μm och precisionen var 10μm. Medelprecisionen inom scanningar var 4μm. Automatisk metod: Riktigheten var 26μm och precisionen var 11μm. Alla testvärden uppvisade stark statistisk deviation från referensvärdet, men väl inom ett kliniskt acceptabelt intervall.Slutsatser. Inom den här in vitro-studiens begränsningar, kan den beskrivna,standardiserade metoden användas manuellt eller med den automatiska funktionen Fittingsphere för att beräkna noggrannheten för intraorala scannrar. Fler studier på mer komplexa objekt behöver utföras. Dessutom uppvisade den intraorala scannern (TRIOS) hög riktighet och precision, jämförbar eller bättre än traditionella avtrycksmetoder inom tandvården. / AbstractBackground. There is no gold standard for determining the accuracy of intraoral scanners. The performances of intraoral scanners given by different manufacturers are not fully comparable. There is a need for standardized and independent test setups to enable the comparison of intraoral scanners.Objectives. The study’s aims were to describe and evaluate a new method for determining the accuracy of any intraoral scanner by means of a standardized geometrical in vitro test and to use this method for determining the accuracy of a commercial intraoral scanner.Material and methods. The Technical Research Institute of Sweden defined the dimensions of a spherical test object. The sphere was spray-coated with TiO2 and scanned 12 times with a commercial intraoral scanner. The scans where evaluated using two methods. Manual method: The diameter of the sphere was measured 12 times for each scan in a software application by adjusting a cross-sectional plane. Automatic method: 12 nominal diameters were obtained with a software application. The accuracy was calculated for each test method and compared. Results. Reference measurement: The defined diameter was 4.9991±0.0001mm. Manual method: Trueness was 25 µm and precision was 10 µm. Mean precision within scans was 4 µm. Automatic method: Trueness was 26 µm and precision was 11 µm. All test values showed sharp significant deviations from the reference value but were well within range of clinical acceptance.Conclusions. Within the limitations of this in vitro study, the standardized in vitro test described can be used manually or with the automatic function Fitting Sphere for determining the accuracy of intraoral scanners. Further studies need to be performed on more complex objects. The commercial intraoral scanner (TRIOS) demonstrates a high level of trueness and precision which is comparable with or better than that shown with traditional impression methods.
6

Efeito da fotopolimerização complementar em resinas para impressoras por estereolitografia em suas propriedades mecânicas e diferentes designs de impressão na precisão de modelos odontológicos /

Almeida, Layene Figueiredo. January 2020 (has links)
Orientador: Lidia Parsekian Martins / Resumo: OBJETIVO: Identificar e quantificar diferenças nas propriedades mecânicas de quatro resinas para impressão por estereolitografia em função do tempo de exposição à luz ultravioleta pós impressão e quantificar diferenças dimensionais em modelos odontológicos produzidos por estereolitografia em relação à inserção de barra estabilizadora transversal na região posterior, à orientação de impressão, vertical ou horizontal, tipo de modelo, oco ou maciço, e pós cura com luz ultravioleta ou não, por meio de medições lineares. MÉTODOS: 140 espécimes foram impressos em impressoras 3D do tipo SLA (estereolitografia a laser) e DLP (estereolitografia por processamento digital de luz) para cada teste mecânico realizado e foram divididos em 28 grupos, de acordo com a resina (4 tipos: Blue, Gray, Surgical Guide, Standard) e o tempo de pós cura com luz ultravioleta (7 tempos: 0, 5, 10, 15, 30, 60 e 120 minutos). Foram realizados os testes de microdureza Vickers, tração diametral e flexão três pontos. Os dados obtidos foram submetidos a uma ANOVA de dois níveis e ao pós teste de Tukey. Para a avaliação das alterações dimensionais de modelos odontológicos foram realizados dois experimentos distintos. No primeiro, 56 modelos odontológicos do arco maxilar em formato de ferradura foram impressos na impressora MoonRay S100 (SprintRay) com a resina Gray (SprintRay), variando a orientação de impressão, a presença de barra e o processo de pós cura. Depois de impressos foram escaneados em escâner de mesa... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: OBJECTIVE: To identify and quantify differences in the mechanical properties of four resins for stereolithography printing varying time of exposure to ultraviolet light and to quantify dimensional differences in dental models produced by stereolithography regarding the insertion of a transverse stabilizer bar in the posterior region, the printing orientation, vertical or horizontal, model type, hollow or solid, and post-cure with ultraviolet light or not, by means of linear measurements. METHODS: 140 specimens were printed by SLA (laser stereolithography) and DLP (digital light processing stereolithography) printers for each mechanical test performed and were divided into 28 groups, according to the resin (4 types: Blue, Gray, Surgical Guide, Standard) and the post-cure time with ultraviolet light (7 times: 0, 5, 10, 15, 30, 60 and 120 minutes). Vickers microhardness tests, diametrical traction and three point flexion were performed. The data obtained were submitted to a two-way ANOVA and the Tukey post-test. To evaluate the dimensional changes of dental models, two different experiments were carried out. In the first, 56 horseshoe-shaped dental models of a maxillary arch were printed on the MoonRay S100 (SprintRay) with Gray resin (SprintRay), varying the printing orientation, the presence of a bar and the post-curing process. After printing, they were scanned on a R700 table scanner (3Shape) and then measurements between canines, first and second premolars and molars and ar... (Complete abstract click electronic access below) / Doutor
7

Análise comparativa da acurácia de modelos impressos, obtidos a partir de escaneamento intra-oral / Comparative analysis of the accuracy of printed casts, obtained from intraoral scanning

Igai, Fernando 28 November 2018 (has links)
A confecção de trabalhos protéticos em um fluxo digital é possível a partir do escaneamento intra-oral e confecção da Prótese via CAD/CAM. A tecnologia atual de impressão 3D permite a obtenção de um modelo impresso, para a realização de determinados procedimentos. Entretanto, é necessário analisar e comparar estes modelos com os modelos de gesso, uma vez que existe uma diferença significativa na forma de obtenção, assim como, nos custos de cada tipo de modelo. O presente estudo teve como objetivo realizar uma análise da acurácia entre modelos impressos, obtidos por meio de escaneamento intra-oral e impressão 3D, e modelos de gesso obtidos pelo método de moldagem convencional. Foi utilizado um manequim odontológico como modelo mestre e foram confeccionados dez modelos de gesso (n= 10), pela técnica de moldagem da dupla impressão com silicone de adição. Foram utilizados dois tipos de escâneres intra-orais e dois tipos de impressoras 3D, que formaram quatro grupos experimentais com dez modelos por grupo (n= 10). Os modelos físicos de gesso e impressos foram comparados com o modelo mestre por meio de análises de medições lineares em seis sítios de medições, com o uso de uma máquina de medição por imagem (Quick Scope, Mitutoyo®). A análise dos modelos impressos incluiu as possíveis interações entre os fatores principais tipo de impressora, tipo de escâner e sítios de medições. Os resultados mostraram que em relação ao modelo mestre, no geral, as discrepâncias dos modelos de gesso foram menores que as discrepâncias dos modelos impressos. A análise das interações dos fatores principais indicou que o tipo de impressora exerceu a maior influência na acurácia dos modelos impressos, seguido do fator sítio de medição e tipo de escâner. Pôde-se concluir que os modelos de gesso apresentaram uma acurácia superior quando comparados com os modelos impressos. O acabamento superficial dos modelos impressos exerceu influência na sua acurácia. / The preparation of prosthetic restoration in a digital flow is possible using intraoral scanning and confection of the prosthesis via CAD/CAM. The current 3D printing technology allows the making of a printed cast, for performing certain laboratory procedures. However, it is necessary to analyze and compare these casts with the gypsum casts, since there is a significant difference in the form of obtaining, as well as, in the costs of each type of cast. The objective of the present study was to perform a comparative study of the accuracy of printed casts, obtained through intraoral scanning and 3D printing, and gypsum casts, obtained through the conventional impression. A dental mannequin was used as the master model and ten gypsum casts (n=10) were obtained, using double impression technique with polyvinyl siloxane. Two types of intraoral scanners and two types of 3D printers were used, which formed four experimental groups with ten models per group (n=10). The real gypsum and printed casts were compared to the master model by linear measurements in six sites, using an image-measuring machine (Quick Scope, Mitutoyo®). The analysis of the printed models included possible interactions between the factors type of printer, type of scanner and measurement sites. The results showed that, in relation to the master model, in general, the discrepancies of the gypsum casts were smaller than the discrepancies of the printed casts. The interactions of the factors analysis indicated that the type of printer exerted the greatest influence on the accuracy of the printed casts, followed by the site measurement and type of scanner. It was conclude that the gypsum casts presented superior accuracy when compared to the printed casts. The surface finish of the printed casts exerted influence in its accuracy.
8

Avaliação da acurácia entre o planejamento assistido por computador e resultados obtidos em cirurgia ortognática: estudo retrospectivo

Marlière, Daniel Amaral Alves 12 January 2018 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2018-03-26T17:47:46Z No. of bitstreams: 1 danielamaralalvesmarliere.pdf: 4530634 bytes, checksum: 35c631563d509dbd177ef9d06c96497b (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2018-04-09T19:15:15Z (GMT) No. of bitstreams: 1 danielamaralalvesmarliere.pdf: 4530634 bytes, checksum: 35c631563d509dbd177ef9d06c96497b (MD5) / Made available in DSpace on 2018-04-09T19:15:15Z (GMT). No. of bitstreams: 1 danielamaralalvesmarliere.pdf: 4530634 bytes, checksum: 35c631563d509dbd177ef9d06c96497b (MD5) Previous issue date: 2018-01-12 / Objetivo: este estudo retrospectivo avaliou a acurácia entre os resultados obtidos e o planejamento assistido por computador (PAC) em cirurgia ortognática por meio do uso de modelos de superfície tridimensionais (3D) para aplicação em algoritmo de proximidade iterativa de pontos (PIP) e produção de mapas de cores por meio de programa computacional de engenharia reversa. Material e Métodos: a partir de arquivos de tomografia computadorizada cone-beam (TCFC) de 25 pacientes submetidos à cirurgia ortognática bimaxilar, foram gerados modelos 3D do PAC e pós-operatório em formato de arquivos STL (M0 e M1, respectivamente). Os M0 e M1 foram importados para programa computacional Geomagic Wrap, sendo aplicada a função de registro por meio do algoritmo PIP para alinhamento automático e cálculos dos desvios médios (MD, MD +, MD -, SD) e quadrado médio da raiz (RMS). Os mapas de cores foram gerados para avaliar a congruência qualitativa entre M0 e M1. A partir da análise dos desvios, os RMS(s) foram definidos como ‘3D Error’ que foi utilizado como indicador de mensuração de acurácia. As características da amostra foram apresentadas por análises de estatística descritiva. Para avaliar a reprodutibilidade do método, o fluxo de trabalho foi realizado por dois avaliadores independentes. Os testes t foram utilizados para avaliar as médias de MD, MD +, MD-, SD e ‘3D Error’, segundo a hipótese de todos os valores fossem menores ou igual a - 2 mm e maiores ou igual a 2 mm. Resultados: foram encontradas altas correlações intra e inter-avaliadores, favorecendo a reprodutibilidade do fluxo de trabalho no Geomagic Wrap. Testes t rejeitaram a hipótese de que os valores MDs e ‘3D Error’ eram menores que - 2 mm e maiores que 2 mm. Conclusão: este estudo apresentou a média de ‘3D Error’ (1,27 mm) estava dentro dos padrões de sucesso clínico inferior a 2 mm. O algoritmo PIP no Geomagic Wrap forneceu um método reprodutível para relacionar as malhas de superfície dos modelos 3D, e mapas de cores foram gerados para avaliar a congruência 3D. No entanto, não há respostas para todos os parâmetros metodológicos em relação à avaliação da acurácia em cirurgia ortognática. / Purpose: The aim of this retrospective study was to evaluate the accuracy between actual outcomes and virtual surgical planning (VSP) in orthognathic surgery regarding the use of three-dimensional (3D) surface models for registration using ICP algorithm and color maps by reverse engineering software. Materials and Methods: Construction of planning and postoperative 3D models in STL files format (M0 and M1, respectively) from CBCTs of 25 subjects who had been submitted to bimaxillary orthognathic surgery was performed. The M0 and M1 were sent to Geomagic Wrap Software in automatic alignment surface meshes order of M0 and M1 for registration using the ICP algorithm to calculate mean deviation (MD, MD+, MD-, SD) and root mean square (RMS). Color maps were generated to assess qualitative congruence between M0 and M1. From deviation analysis, the RMS(s) were defined as 3D Error which behaved as a measurement indicator of accuracy. The sample characteristics were shown by descriptive statistics. To evaluate the reproducibility of this method, the workflow was performed by two independent evaluators multiple times. t tests were used to assess whether all means of MD, MD+, MD-, SD and 3D Error values would be lower than - 2 mm and greater than 2 mm. Results: high intra and inter evaluators correlation were found, supporting the reproducibility of the workflow in Geomagic Wrap software. t tests proved that all MD(s) and 3D Error values were greater than - 2 mm and lower than 2 mm. Conclusion: This study showed 3D error mean (1,27 mm) within the standards of clinical success lower than 2 mm. ICP algorithm in Geomagic Wrap software provided a reproducible method of alignment between 3D models (surface meshes) and generated color maps to evaluate 3D congruence, but did not answer all methodological parameters regarding the assessment of accuracy in orthognathic surgery.
9

Avaliação da alteração dimensional de quatro siliconas por condensação através da medição tridimensional por coordenadas / Evaluation of dimensional change of four condensation silicones by three dimensional coordinate measuring

Monteiro, Jaiane Bandoli 30 April 2015 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2015-12-03T16:47:38Z No. of bitstreams: 1 jaianebandolimonteiro.pdf: 2039791 bytes, checksum: c3f28c1a95fdef73d0cc0190a9dfa169 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2015-12-03T21:29:38Z (GMT) No. of bitstreams: 1 jaianebandolimonteiro.pdf: 2039791 bytes, checksum: c3f28c1a95fdef73d0cc0190a9dfa169 (MD5) / Made available in DSpace on 2015-12-03T21:29:38Z (GMT). No. of bitstreams: 1 jaianebandolimonteiro.pdf: 2039791 bytes, checksum: c3f28c1a95fdef73d0cc0190a9dfa169 (MD5) Previous issue date: 2015-04-30 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo foi avaliar a alteração dimensional dos moldes de silicona por condensação imediatamente, 30min, 1h e 7 dias após a moldagem, com o auxílio da máquina de medição tridimensional por coordenadas. Os grupos foram divididos em: G1: Speedex Putty/Speedex Light Body (Coltene/Vigodent AS Indústria e Comércio), G2: Optosil P Plus/Xantopren L Blue (Heraeus Kulzer GmbH), G3: Zetaplus Putty/Oranwash L (Zhermack SpA) e G4: Precise SX (Dentsply Indústria e Comércio Ltda). Para a obtenção das 80 medições dos 4 materiais (n=20), foi usado um dispositivo composto por uma moldeira perfurada e uma outra parte com 3 edentações pré-estabelecidas. Para a avaliação dimensional, a máquina Crysta-Plus M 574 (Mitutoyo) realizou cada medida 3 vezes nos tempos estabelecidos e obteve-se a média aritmética. A média final das 4 distâncias I, II, III e IV do dispositivo edentado foi novamente aplicada. A análise estatística foi realizada com o teste de Kolmogorov-Smirnov que rejeitou a hipótese nula de distribuição assimétrica. Posteriormente, foi feita a ANOVA para comparar os 4 materiais simultaneamente e o teste paramétrico t de Student para comparar os materiais 2 a 2. O nível de significância global foi de p≤0,05. A maior contração linear foi observada na Speedex, mas não foi significante (p=0,08). A Zetaplus Putty/Oranwash L parece ser a mais estável (p=0,99), mas não foi significante. Não houve diferença estatisticamente significante entre nenhuma silicona por condensação quando comparadas simultaneamente nos 4 tempos ou quando comparadas 2 a 2, à exceção, Precise SX e a Speedex (p=0,05) no tempo T3. Todas as siliconas por condensação testadas apresentam alteração dimensional clinicamente aceitável e podem ser vazadas imediatamente, 30min, 1h e 7 dias após a moldagem. / The purpose was to evaluate the dimensional changes of condensation silicone impressions by immediately, 30min, 1h and 7 days after impression, with the help of threedimensional measuring coordinate machine. The groups were divided in: G1: Speedex Putty/Speedex Light Body (Coltène/Vigodent S/A Ind and Com), G2: Optosil P Plus/Xantopren L Blue (Heraeus Kulzer GmbH), G3: Zetaplus Putty/Oranwash L (Zhermack SpA) and G4: Precise SX (Dentsply Ind and Com Ltda). To obtain 80 measurements of 4 material (n=20) was used a device consisting of a perforated tray and one another part with 3 pre-established indentations. For dimensional evaluation, the Crysta-Plus M574 machine (Mitutoyo) held each measurement 3 times at the established times and obtained the arithmetic mean. The final average of the 4 distances of I, II, III and IV the edentulous device was again applied. Statistical analysis was performed using the Kolmogorov-Smirnov test to reject the null hypothesis of asymmetric distribution. Subsequently, ANOVA was performed to compare the four materials simultaneously and Student's t parametric test to compare the 2 by 2 materials. The overall significance level of p≤0,05. The higher linear contraction was observed in Speedex, but was not significant (p=0,08). The Zetaplus Putty/Oranwash L seems to be more stable (p=0,99) but was not significant. There was no significant difference between any silicone condensation compared simultaneously in 4 times or compared 2 by 2, except, Precise SX and Speedex (p=0,05) in T3 time. All tested condensation silicones exhibit clinically acceptable dimensional change and can be leaked immediately, 30min, 1h and 7 days after impression.
10

Avaliação volumétrica da face: validação do sistema de captação de imagem facial tridimensional pela tecnologia de luz estruturada, estudo em cadáver / Volumetric evaluation of the face: validation of the three-dimensional facial image capture system by structured light technology, cadaver study

Dornelles, Rodrigo de Faria Valle 30 January 2019 (has links)
A avaliação volumétrica da face é uma medida dimensional importante na avaliação pré-operatória, no planejamento e acompanhamento pós-operatório. Os sistemas de imagem tridimensional (3D) têm sido considerados uma ótima alternativa na mensuração linear, angular e volumétrica da face em comparação com as imagens bidimensionais (2D). Especificamente na área de atuação da Cirurgia Crânio-Maxilo-Facial, o uso da imagem em 3D na avaliação das malformações congênitas, sequelas de traumas, sequelas tumorais, planejamento de cirurgias ortognáticas, simulação de mudanças volumétricas, assimetrias faciais e outros, pode tornar o tratamento mais objetivo, rápido e potencializar os resultados. O objetivo deste projeto foi a avaliação da acurácia do cálculo volumétrico das partes moles da face a partir de malhas 3D de superfície, estudo em cadáver. Foram avaliados 09 cadáveres oriundos do Sistema de Verificação de Óbito da Capital - Universidade de São Paulo (SVO-USP). Foi incluído um expansor tecidual na região do terço médio de cada hemiface, que foi expandido progressivamente e, por meio de captação seriada de imagens tridimensionais da face com escâner de luz estruturada, foram obtidas malhas de superfície 3D a cada momento de expansão. As malhas 3D foram avaliadas quanto a variação volumétrica da região de inclusão do expansor com o uso de um software livre. O cálculo amostral supôs que as correlações encontradas apresentariam valores acima de 0,80. Para testes com poder de 80% e nível de significância de 5% seriam necessários, então, 18 hemifaces no estudo. Uma forte correlação foi observada entre todas as medições. Os gráficos de correlação linear evidenciaram um aumento linear positivo uniforme para os diferentes volumes virtuais avaliados em todas as 18 hemifaces estudadas. Todas as hemifaces não expandidas tiveram um delta significativamente menor em seções externas do cubo virtual medidas em comparação com seções externas do cubo virtual dos lados da face com expansor (P = 0,008). O grau excelente de correlação entre o volume expandido e o volume aferido virtualmente, evidenciou que obtenção de 144 malhas 3D (9 faces, 18 hemifaces, cada uma utilizada 2 vezes, uma com expansor e outra sem, totalizando 36 hemifaces estudadas com 4 malhas 3D para cada) foi uma amostra adequada para o estudo. O protocolo apresentado para o cálculo volumétrico da face com o processamento de imagem 3D assistido por computador e com a utilização de software livre em um estudo em cadáver, demonstrou versatilidade e acessibilidade, tendo sido comprovada a sua acurácia / The face volumetric evaluation is an important dimensional measure in the preoperative evaluation in planning and postoperative follow-up. 3D imaging systems have been considered a good alternative in linear and angular measurement of face compared to 2D images. Specifically, in Cranio-Maxillofacial Surgery area, the 3D imaging use in the evaluation of congenital malformations, trauma sequelae, tumor sequelae, orthognathic surgery planning, volumetric changes simulation, facial imbalances and others could turn the treatment more objective, faster and potentiate the results. This project objective was calculation volumetric accuracy evaluation of the soft face parts from 3D surface meshes cadaver study. We evaluated 9 cadavers from the Sistema de Verificação de Óbito da Capital - Universidade de São Paulo (SVO-USP). A tissue expander was included in each middle third hemiface region which was progressively expanded and by means of serial three-dimensional face images acquisition with light scanners surface 3D meshes structured were obtained at expansion each moment. The 3D meshes were evaluated for the expander inclusion region volumetric variation with free software use. The sample calculation assumed that the correlations found would have values above 0.80. Eighteen hemifaces would be necessary in the study for tests with a power of 80% and a level of significance of 5%. A strong correlation was observed between all measurements. The linear correlation graphs showed a positive consistent linear increase for different virtual volumes evaluated in all 18 hemifaces studied. All unexpanded hemifaces had a significantly lower delta in outer virtual cube measured sections compared to virtual cube on face sides with expander (P = 0.008) external sections. The excellent degree of correlation between the expanded volume and the virtually verified volume showed that obtaining 144 3D meshes (9 faces, 18 hemifaces, each one used 2 times, one with expander and one without, totaling 36 hemifaces studied with 4 3D meshes for each) was an adequate sample for the study. The protocol presented for face volumetric calculation with computer assisted 3D image processing and the free software use in a cadaver study demonstrated versatility and accessibility and its accuracy was proven

Page generated in 0.1451 seconds