• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 441
  • 314
  • 124
  • 60
  • 30
  • 23
  • 22
  • 16
  • 15
  • 11
  • 6
  • 5
  • 4
  • 4
  • 4
  • Tagged with
  • 1425
  • 472
  • 228
  • 154
  • 138
  • 113
  • 113
  • 109
  • 105
  • 100
  • 99
  • 97
  • 96
  • 88
  • 87
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

Curvas de dose resposta e isobologramas como forma de descrever a associação dos inibidores da ALS (sulfometuron-methyl e chlorimuron-ethyl) em Digitaria insularis (L.) Fedde / Dose response curves and isobolograms as way of describing the association of the ALS inhibitors (sulfometuron-methyl e clorimuron-ethyl) in Digitaria insularis (L.) Fedde

Marco Antonio Paris Junior 15 June 2018 (has links)
O interesse em efeitos sinérgicos ou antagônicos através de experiências com associações cresceu imensamente nas últimas décadas. Com o objetivo de estudar a associação de dois herbicidas inibidores da ALS (sulfometuron-methyl e chlorimuron-ethyl) em Digitaria insularis, empregou-se dos métodos estatísticos fornecidos por meio das curvas dose-resposta e isobologramas. O conceito de curvas dose-resposta tem sido amplamente utilizado para avaliar os resultados das experiências com herbicidas. No entanto, a abordagem estatística em torno das curvas deve ser cuidadosa; cosiderar as curvas dose-resposta semelhantes quando elas não são pode influenciar muito na comparação entre as moléculas e afetar o cálculo da potência relativa. A potência relativa ajuda a entender qual é a relação de potência entre as moléculas, esse conhecimento é fundamental para os estudos com os herbicidas em associação. Sabendo-se disso foram conduzidos experimentos do tipo dose-resposta em dois tipos de substratos utilizando Digitaria insularis como planta daninha indicadora. Os experimentos foram conduzidos em casa de vegetação do Centro de Pesquisa e Desenvolvimento da DuPont em Paulínia (SP). Para cada molécula foram aplicadas, em pré-emergência, oito doses com quatro repetições cada e quatro plantas testemunha nos diferentes substratos. O substrato A é somente substrato comercial (marca Tropstrato HT®) puro; E o substrato B é uma mistura de solo arenoso, peneirado e livre de contaminação mais substrato comercial na proporção 3:1 v/v. Neste caso ficou evidente a maior capacidade do sulfometuronmethyl em reduzir a biomassa da espécie, as curvas dose-resposta foram descritas pelo modelo log-logístico com os valores de ED50 e as declividades de cada curva variando livremente, pois as hipóteses testadas nos diferentes substratos de curvas paralelas foram rejeitadas. O valor calculado da potência relativa para o nível de resposta de 50% entre os herbicidas CLASSIC® (chlorimuron-ethyl) e CURAVIAL® (sulfometuron-methyl) nas condições desse estudo foi de 8,596 e 44,047 nos Substrato A e B respectivamente. A partir dessa informação foram utilizadas as mesmas condições do experimento anterior para o experimento com as isoboles dos herbicidas em associação, cinco curvas dose-resposta, foram propostas, duas curvas para os produtos isolados e três curvas para as associações em diferentes proporções [(25% : 75%); (50% : 50%); (75% : 25%)] chlorimuron-ethyl / sulfometuron-methyl, totalizando 144 parcelas. Vários modelos isoboles foram testados, o modelo de Concentração Aditiva foi significativamente descartado, mas foi levado em consideração para testar teoricamente o grau de sinergia ou antagonismo que modelos mais complexos podiam fornecer. O modelo de isobole proposto por Hewlett e Plackett (1959) teve ajuste significativo e parâmetro de interação menor que um (λ=0,33). O modelo que mais se ajustou aos dados foi o proposto por Vølund e os resultados também mostraram que nessas condições a associação de sulfometuron-methyl com chlorimuron-ethyl foi antagônica; as isoboles são potentes ferramentas para capturar e descrever associações de herbicidas. Entretanto a literatura mostra que associar duas moléculas e testar em um sistema biológico complexo sofrendo variações das diferentes condições ambientais possíveis pode gerar respostas variáveis, portanto esses resultados devem ser repetidos em outras condições para validar as conclusões ou então serem executados em condições controladas de laboratório e usar organismos vivos de menor complexidade como bioindicador. / The interest in synergistic or antagonistic effects through experiences with associations has immensely grown in recent decades. In order to study the association of two ALS inhibitor herbicides (sulfometuron-methyl and chlorimuronethyl) in Digitaria insularis, the statistical methods provided by the dose-response curves and isobolograms were used. The concept of dose-response curves has been widely used to evaluate the results of herbicide experiments. However, the statistical approach around curves must be careful; considering the dose-response curves when they are not can greatly influence the comparison between molecules and affect the calculation of relative potency. Relative potency helps to understand what the power ratio is between molecules, this knowledge is fundamental for studies with herbicides in association. Knowing this, dose-response experiments were conducted on two types of substrates using Digitaria insularis as an indicator weed. The experiments were conducted in a greenhouse of the DuPont Research and Development Center in Paulínia (SP). For each molecule were applied, in pre-emergence, eight doses with four replicates each and four control plants on different substrates. Substrate A is pure commercial substrate (brand Tropstrato HT®); and substrate B is a mixture of sandy soil, sifted and contamination-free plus commercial substrate in the ratio 3:1 v/v. In this case it was evident the greater capacity of the sulfometuron-methyl to reduce the biomass of the species, the dose-response curves were described by the log-logistic model with the values of ED50 and the slopes of each curve varying freely, since the hypotheses tested in the different substrates of parallel curves were rejected. The calculated value of relative potency for the 50% response level between CLASSIC® (chlorimuron-ethyl) and CURAVIAL® (sulfometuron-methyl) herbicides under the conditions of this study was 8.596 and 44.047 on Substrate A and B respectively. From this information the same conditions of the previous experiment for the isoboles of the herbicides in association were used, five doseresponse curves were proposed, two curves for the isolated products and three curves for the associations in different ratios [25% : 75%); (50% : 50%); (75% : 25%)] chlorimuron-ethyl / sulfometuron-methyl, totaling 144 plots. Isoboles models were tested, the Concentration Additive model was significantly discarded, but was taken into account to theoretically test the degree of synergy or antagonism that more complex models could provide. The isobole model proposed by Hewlett and Plackett (1959) had a significant adjustment and interaction parameter smaller than 1 (λ = 0.33). The model that best fit the data was the one proposed by Vølund and the results also showed that under these conditions the association of sulfometuronmethyl with chlorimuron-ethyl was antagonistic; isoboles are potent tools for capturing and describing herbicide associations. So these results must be repeated in other conditions to validate the conclusions or to be executed in controlled laboratory conditions and to use living organisms of lesser complexity as a bioindicator.
152

Distribuições de limiar de dose e suas causas e consequências em Terapia Fotodinâmica / Threshold dose distributions and its causes and consequences in photodynamic therapy

Clara Maria Gonçalves de Faria 22 February 2017 (has links)
O princípio de terapia fotodinâmica (TFD) foi introduzido por volta de 1900 mas posteriormente investgado como candidato para tratamento de cancer na década de 1970. Desde então, existem diversos trabalhos a respeito do assunto in vitro, in vivo e em estudos clínicos e grandes avanços foram alcançados. Entretanto, alguns desafios ainda não foram superados, como a variabilidade dos resultados. Este trabalho consiste na investigação de suas causas, em que o principal objetivo é avançar o estado da arte em TFD. Para isso foi usado um modelo de distribuição de limiar de dose para avaliar resistência em TFD in vitro. As distribuições de limiar de dose são obtidas pela derivação a curva de dose resposta experimental. Elas são caracterizadas pela sua largura e pela dose que corresponde ao pico, que se relaciona a homogeneidade e resistência intrínseca da população, respectivamente. Na seção 1, é apresentada a avaliação e comparação de dados obtidos de resultados publicados na literatura e, na seção 2, de experimentos realizados pela autora em diferentes linhagens celulares. Da análise da primeira etapa, foi observado que a largura da distribuição é proporcional a dose do pico e foi possível investigar a dependência do resultado da TFD com a linhagem celular, dado um fotossensibilizador (FS). Foi interessante, também, notar que as distribuições de limiar de dose correspondem a curvas de atividade de marcadores celulares de apoptose, como função da dose de luz, para a maior parte das condições analisadas. Dos experimentos realizados pela autora, foi visto que as células normais são as mais resistentes ao dano, seguida das células de câncer resistentes e sua linhagem parental, e que sua resposta foi a mais homogênea. Essas observações foram corroboradas pelas imagens obtidas de microscopia de fluorescência para avaliação da captação de FS, que mostraram que as células tumorais acumulam mais FS que as outras. Portanto, foi mostrado o potencial de se aplicar distribuições de limiar de dose na análise de resultados de TFD in vitro, ela é uma poderosa ferramenta que fornece mais informações que as curvas de dose resposta padrão. / The principle of photodynamic therapy (PDT) was introduced around 1900 but further investigated as a candidate to cancer treatment in the 1970´s. Since then, there are several papers regarding the subject in vitro, in vivo and clinical trials and great advances were achieved. However, some challenges were not yet overcome, such as results variability. This work consists in the investigation of its causes, where the main goal is to advance the state of art of PDT. For that it is being used a threshold dose distribution model to evaluate cell resistance to PDT in vitro. The threshold distributions are obtained by differentiating the experimental dose response curve. They are characterized by its width and the dose that corresponds to the peak which relates to the homogeneity and intrinsic resistance of the population, respectively. In section 1, it is presented the evaluation and comparison of data obtained from published results in literature and, in section 2, of experiments performed by the author in different cell lines. From the analysis in the first part, it was observed that the width of the distribution is proportional to its dose of the peak and it was possible to investigate the dependence of the PDT result with the cell line, given a fixed photosensitizer (PS). It was also interesting to note that the threshold distribution corresponded to the activity curves for apoptotic cell markers as a function of light dose, for most of the conditions analyzed. From the experiments performed by the author, it was seen that the normal cell line was the most resistant one, followed by the resistant cancer cells and its parental cell line, and that its response was more homogeneous. Those finding were supported by the fluorescence microscopy images obtained to evaluate PS uptake, which shown that the tumor cells accumulated more PS than the other ones. Therefore, it was shown the potential of applying the threshold distribution to analyze PDT results in vitro, it is a powerful tool that provides more information than the standard dose response curves.
153

Estudo da exalação de radônio em placas e tijolos de fosfogesso de diferentes procedências / Study of radon exhalation from phosphogypsum plates and blocks from different origins

Lucas José Pereira da Costa 13 December 2011 (has links)
O fosfogesso é um resíduo da indústria de fertilizantes fosfatados que concentra radionuclídeos naturais. Neste trabalho foi estudada a taxa de exalação de 222Rn em placas e tijolos de fosfogesso, visando sua utilização na construção de residências. Para tanto, foram determinadas a taxa de exalação de 222Rn por meio da técnica da câmara de acumulação com detectores sólidos de traços nucleares (SSNTD) inseridos em uma câmara de difusão e a dose efetiva para um indivíduo habitando uma residência construída com esses materiais. A título de comparação foi também determinada a taxa de exalação teórica, por meio do modelo proposto pela UNSCEAR, a partir da concentração de 226Ra nas placas e tijolos de fosfogesso. A contribuição do revestimento na superfície dos materiais para a diminuição da taxa de exalação de radônio foi também avaliada. Foram estudados placas e tijolos fabricados com fosfogesso das empresas Bunge Fertilizantes, Ultrafertil e Fosfertil e tijolos fabricados com gesso comum. Os valores médios obtidos foram 0,19 0,06 Bq m-2 h-1, 1,3 0,3 Bq m-2 h-1 e 0,41 0,07 Bq m-2 h-1 para as placas fabricadas com fosfogesso proveniente das empresas Bunge, Ultrafertil e Fosfertil, respectivamente. Já para os tijolos de fosfogesso, os valores foram 0,11 0,01 Bq m-2 h-1, 1,2 0,6 Bq m-2 h-1, 0,47 0,15 Bq m-2 h-1, para o fosfogesso da Bunge, Ultrafertil e Fosfertil. O tijolo fabricado com gesso comum apresentou valor médio de 0,18 0,08 Bq m-2 h-1. As doses efetivas anuais para um indivíduo habitando uma residência construída como os tijolos ou placas de fosfogesso de qualquer uma das procedências ficaram abaixo do limite de dose efetiva para indivíduos do público de 1 mSva-1 estabelecido pela Comissão Internacional de Proteção Radiológica. / Phosphogypsum is a waste of the fertilizer industry that concentrates radionuclides. In this work, the 222Rn exhalation rate from phosphogypsum paltes and blocks from different origins used at dwellings construction was studied. The 222Rn exhalation rate was determined through the accumulation chamber technique with solid state nuclear track detectors (SSNTD). The effective dose for an individual living in a residence built with phosphogypsum based materials was evaluated. It also was calculated the 222Rn exhalation rate through the UNSCEAR model, from the 226Ra concentration in the materials, in order to compare the experimental results. It was evaluated the contribution of building component (paint) to the reduction of 222Rn exhalation rate. The plates and blocks were manufactured with phosphogypsum from Bunge Fertilizantes, Ultrafertil and Fosfertil. Blocks manufactured with ordinary gypsum was also evaluated. The average results obtained were 0.19 ± 0.06 Bq m-2 h-1, 1.3 ± 0.3 Bq m-2 h-1 and 0.41 ± 0.07 Bq m-2 h-1for plates manufactured with phosphogypsum from Bunge Fertilizer, Ultrafertil and Fosfertil, respectively. For the phosphogypsum blocks the values were 0.11 ± 0.01 Bq m-2 h-1, 1.2 ± 0.6 Bq m-2 h-1, 0.47 ± 0.15 Bq m-2 h-1, for Bunge, Ultrafertil and Fosfertil. The blocks manufactured with ordinary gypsum presented average value of 0.18 ± 0.08 Bq m-2 h-1. All phosphogypsum plates and blocks evaluated in this study presented effective dose for radon inhalation lower than the recommended value of 1mSv y1, the annual effective dose limit for public exposure by International Commission on Radiological Protection.
154

Desenvolvimento de uma metodologia de calibração e testes de medidores de produto Kerma-Área / Development of a calibration methodology and tests of kerma area product meters

Nathalia Almeida Costa 20 June 2013 (has links)
A grandeza produto kerma-área (PKA) é importante para estabelecer níveis de referência em exames de radiologia diagnóstica. Essa grandeza pode ser obtida por meio de medidores do PKA. O uso desses medidores é fundamental para avaliar a dose de radiação em procedimentos radiológicos, além de ser um bom indicador para que os limites de dose na pele do paciente não sejam excedidos. Algumas vezes, esses medidores vêm acoplados a equipamentos de radiação X, o que dificulta sua calibração. Neste trabalho foi desenvolvida uma metodologia de calibração de medidores do PKA. O instrumento utilizado para este fim foi o Patient Dose Calibrator (PDC). Ele foi desenvolvido para ser utilizado como referência na verificação da calibração de medidores do PKA e kerma no ar usados na dosimetria de pacientes e para verificação da consistência e do comportamento de sistemas de controle de exposição automáticos. Por se tratar de um equipamento novo, que, no Brasil, ainda não é utilizado como equipamento de referência para calibração, foi realizado, também o controle de qualidade deste equipamento, com testes de caracterização, a calibração e a avaliação da dependência energética. Após os testes, ficou provado que o PDC pode ser utilizado como instrumento de referência para a calibração a ser realizada in situ, de forma que as características de cada equipamento de radiação X onde os medidores do PKA são utilizados sejam consideradas. A calibração foi, então, realizada com medidores do PKA portáteis e em um equipamento de radiologia intervencionista que possui um medidor do PKA acoplado. Os resultados foram bons e ficou provada a necessidade de calibração desses medidores e a importância da calibração in situ com um medidor de referência. / The quantity kerma area product (PKA) is important to establish reference levels in diagnostic radiology exams. This quantity can be obtained using a PKA meter. The use of such meters is essential to evaluate the radiation dose in radiological procedures and is a good indicator to make sure that the dose limit to the patient\'s skin doesnt exceed. Sometimes, these meters come fixed to X radiation equipment, which makes its calibration difficult. In this work, it was developed a methodology for calibration of PKA meters. The instrument used for this purpose was the Patient Dose Calibrator (PDC). It was developed to be used as a reference to check the calibration of PKA and air kerma meters that are used for dosimetry in patients and to verify the consistency and behavior of systems of automatic exposure control. Because it is a new equipment, which, in Brazil, is not yet used as reference equipment for calibration, it was also performed the quality control of this equipment with characterization tests, the calibration and an evaluation of the energy dependence. After the tests, it was proved that the PDC can be used as a reference instrument and that the calibration must be performed in situ, so that the characteristics of each X-ray equipment, where the PKA meters are used, are considered. The calibration was then performed with portable PKA meters and in an interventional radiology equipment that has a PKA meter fixed. The results were good and it was proved the need for calibration of these meters and the importance of in situ calibration with a reference meter.
155

Estudo da influência de partículas de ouro na dose absorvida em tecido mole utilizando dosimetria com gel polimérico / Study of the influence of gold particles on the absorbed dose in soft tissue using polymer gel dosimetry

Luciana Caminha Afonso 04 October 2011 (has links)
A presença de material de alto número atômico adjacente ao tecido mole aumenta localmente a dose absorvida pelo tecido quando submetido à radiação. Este efeito ocorre devido aos fotoelétrons ejetados do material de alto número atômico. Dosímetros de gel polimérico com partículas de ouro foram utilizados para investigar este efeito. Foram realizados cálculos analíticos para estimar o aumento de dose e simulações com o método de Monte Carlo. A irradiação de amostras de gel polimérico (GP) puro e com 0,005 gAu/gGP utilizando um feixe de raios X produzido por um potencial de 150 kV filtrado com 4 mmAl e 5 mmCu resultou em uma dose absorvida pelas amostras com ouro aproximadamente 20% maior que a dose absorvida pelas amostras de gel polimérico puro. Os cálculos analíticos e a simulação com o método de Monte Carlo resultaram em um aumento de aproximadamente 30% na dose absorvida. / The presence of high-Z material adjacent to soft tissue, when submitted to irradiation, enhances locally the absorbed dose in these soft tissues. Such effect occurs due to the outscattering of photoelectrons from the high-Z material. Polymer gel dosimeters have been used to investigate this effect. Analytic calculations to estimate the dose enhancement and Monte Carlo simulations have been performed. Samples containing polymer gel (PG) with 0.005 gAu/gPG and pure polymer gel have been irradiated using an X-rays beam produced by 150 kV, filtered with 4 mm Al and 5 mm Cu, which resulted in an approximately 20% higher absorbed dose in the samples with gold in comparison to those with pure polymer gel. The analytic calculations and the Monte Carlo simulation resulted in a dose enhancement factor of approximately 30%.
156

Desenvolvimento de uma metodologia para calibração de câmaras de ionização de placas paralelas em feixes de raios X de energia baixa em termos de dose absorvida em água / Development of a methodology for calibration of parallel plate ionization chambers for X-ray beams of low energy in terms of absorbed dose to water

Camila Trindade de Oliveira 10 December 2015 (has links)
O objetivo deste trabalho foi estabelecer uma metodologia de calibração em termos de dose absorvida na água para câmaras de ionização de placas paralelas a serem utilizadas em feixes de radiação X de energia baixa (10 kV a 100 kV) para fins terapêuticos. Atualmente, no Brasil nenhum laboratório de calibração está oferecendo este tipo de serviço. Para o estabelecimento desta metodologia de calibração foram utilizadas duas câmaras de ionização PTW modelos 23344. Ambas as câmaras foram caracterizadas e testadas qualitativamente segundo recomendações de normas internacionais. Os testes de caracterização realizados foram: a medição da taxa de dose mínima efetiva, a curva de saturação, a eficiência da coleção de íons, a resposta quanto ao efeito da polaridade e a linearidade da câmara com a resposta. Os testes de controle de qualidade aplicados foram: estabilidade em curto e longo prazos, fuga de corrente sem irradiação, fuga de corrente após-irradiação e tempo de estabilização. Para a implantação da metodologia, foram estabelecidas as qualidades de radiação de T-10 a T-100, seguindo as recomendações do código de prática da AIEA. Desta forma, foi possível determinar a grandeza de referência, dose absorvida na água, utilizando-se as duas câmaras de ionizações e em todas as qualidades estabelecidas. / The objective of this study was to establish a calibration methodology in terms of absorbed dose to water for parallel plate ionization chambers to be used in low energy X rays beams (10kV to 100kV) for therapy purposes. Currently, in Brazil no calibration laboratory is offering this type of service. In order to establish this calibration methodology was used two ionization chambers PTW models 23344. Both chambers were characterized and tested qualitatively according to recommendations of international standards. The characterization tests performed were: measuring the effective minimum dose rate, the saturation curve, the efficiency of ions collection, polarity effect and the linearity of the ionization chamber with the response. The quality control tests applied were: stability in the short and long term, leakage current without irradiation, leakage current after irradiation and settling time. For the implementation of the methodology, the radiation qualities the T- 10 to T-100 were established, following the recommendations of the IAEA code of practice. Thus, it was possible to determine the magnitude of reference absorbed dose in water, using the two ionization chambers in the all established qualities.
157

Desenvolvimento de um sistema de referência para determinação do equivalente de dose pessoal e da constância de feixes de radiação X / Development of a reference system for the determination of the personal dose equivalent and the constancy of X-ray beams

Vitor Vivolo 09 February 2006 (has links)
Um sistema de referência para determinação do equivalente de dose pessoal, HP (10), e um programa de controle da qualidade de sistemas geradores de raios X utilizados em radioproteção inclui a verificação periódica da constância dos feixes de raios X empregados na calibração de instrumentos medidores de radiação em laboratórios de calibração de instrumentos. Neste trabalho foram desenvolvidas duas câmaras de ionização de placas paralelas inseridas em objetos simuladores de tronco humano. Uma das câmaras de ionização possui eletrodo coletor de grafite, para a medida do equivalente de dose pessoal; a segunda câmara de ionização foi confeccionada com eletrodo coletor de alumínio para, juntamente com a primeira câmara de ionização, formarem um sistema Tandem. A dependência energética diferente da resposta das duas câmaras de ionização é que permite a formação do sistema Tandem, que apresenta grande utilidade na verificação da constância de feixes de radiação X. Foram ainda implantados feixes padronizados de radiação X de energias médias (48 keV a 118 keV), nível radioproteção, por meio do desenvolvimento de uma metodologia dosimétrica e da análise dos parâmetros físicos destes feixes. As câmaras desenvolvidas foram testadas em relação às suas características operacionais e foram calibradas em feixes de radiação X, níveis radioproteção, radiodiagnóstico, mamografia e radioterapia, e ainda em campos de radiação gama, seguindo as recomendações internacionais. Apresentaram bom desempenho. Foi estabelecido o procedimento da determinação do equivalente de dose pessoal, Hp (10). / A reference system for the determination of the personal dose equivalent, HP (10), and a quality control program of X-ray equipments used in radioprotection require the periodic verification of the X-ray beams constancy. In this work, two parallel-plate ionization chambers were developed with inner electrodes of different materials, and inserted into PMMA slab phantoms. One ionization chamber was developed with inner carbon electrodes and the other with inner aluminium electrodes. The two ionization chambers can be used as a Tandem system. The different energy response of the two ionization chambers allowed the development of the Tandem system that is very useful for the checking of the constancy of beam qualities. Standard intermediary energy X-ray beams (from 48 keV to 118 keV), radioprotection level, were established through the development of a dosimetric methodology and the analysis of their physical parameters. The ionization chambers were studied in relation to their operational characteristics, and they were calibrated in X-ray beams (radioprotection, diagnostic radiology, mammography and radiotherapy levels) in accordance to international recommendations. They presented good performance. The determination procedure of personal dose equivalent, HP (10), was established.
158

Estudo da resposta alérgica à tuberculina em ovinos (Ovis aries) experimentalmente sensibilizados, conforme a região corpórea e a dose de PPD utilizada / Study of the allergic response to tuberculin in sheep (Ovis aries) experimentally sensitized, according to body region and PPD\'s dose used.

Silva, Danielle Yuri Massukado Rodrigues da 20 August 2010 (has links)
Diante da importância do tema, a pobreza de dados nacionais sobre a tuberculose em ovinos e a necessidade de aprofundamento de conhecimento sobre a aplicação das técnicas de diagnóstico pertinentes ao combate e erradicação da tuberculose animal, foi delineado o presente estudo. Esta pesquisa visou avaliar a melhor região corpórea e dose de derivado protéico purificado (PPD) bovino a ser aplicada em ovinos (Ovis aries) experimentalmente sensibilizados comMycobacterium bovis AN5 para diagnóstico de tuberculose. Utilizou-se 15 ovinos clinicamente sadios e negativos à prova de Tuberculina Cervical Comparativa (TCC), segundo os padrões estabelecidos por Cyrillo et al. (2007), em duas fases: primeira etapa avaliação do melhor local de aplicação do PPD bovino em ovinos; segunda etapa a partir do melhor local de aplicação, a dose de PPD bovino a ser aplicada. Imediatamente após a leitura do TCC de triagem inicial, os ovinos foram sensibilizados com o inóculo inativado de M. bovis estirpe AN5, e após um período de dessensibilização de 60 dias entre aplicações, realizou-se a avaliação de cinco regiões corpóreas, com a mensuração da espessura da dobra de pele efetuada nos momentos antes (0h) e após aplicação (12h, 24h, 48h, 72h e 96 horas). As análises estatísticas mostraram uma significância para os melhores locais de aplicação, a saber: regiões torácica dorsal, seguida da cervical média e abdominal dorsal em 48 e 72 horas após aplicação de PPD bovino. Eleita a região torácica dorsal (p=0,94) como o melhor local de aplicação, os resultados da reação frente às diferentes doses (0,05 mL; 0,1 mL e 0,2 mL), expressos em espessura da dobra de pele, indicaram que não houve diferenças significantes entre as doses e momentos de leitura, sendo recomendada a aplicação de 0,1 mL de PPD bovino e leitura com 72 horas após aplicação. / Given the importance of the topic, the paucity by National data of tuberculosis in sheep, and the need to deepen knowledge about diagnostic techniques application relevant to combat and eradication of animal tuberculosis, the present study was designed. This study aimed to evaluate the best body region and dose of bovine purified protein derivative (PPD b) to be used in sheep (Ovis aries) experimentally sensitized to Mycobacterium bovis AN5 to tuberculosis diagnoses. It was used 15 clinically healthy sheep and negative to the Comparative Cervical skin Test (CCT), according to standards established by Cyrillo et al. (2007), in two phases: first part - assessment of the best application area of bovine PPD in sheep; second part - from the best sites for the application, the best dose of bovine PPD to be applied. Immediately after reading the initial screening CCT, the animals were sensitized with the inoculation of inactivated M. bovis strain AN5, and after a 60 days period of desensitization between applications, was carried out an assessment of five body regions, the skin fold thickness was measured before (0h) and after injection (12h, 24h, 48h, 72h and 96 hours). Statistical analysis showed significance to the best site of application: dorsal thoracic region, followed by middle cervical and dorsal abdominal, according to 48 and 72 hours after injection of bovine PPD. Chosen the thoracic region (p = 0.94) as the best site for the application, results of reaction from different doses (0.05 mL, 0.1 mL, and 0.2 mL), expressed as skin fold thickness showed no significant differences between doses and times of measurement, it was recommended the application of 0.1 mL of bovine PPD and measure at time 72 hours after injection.
159

Estimativa de dose efetiva de radiação recebida por pacientes submetidos a exames de tomografia computadorizada e proposta para registro de dose por paciente em sistema de informação de radiologia / Effective dose estimate received by patients undergoing computed tomography scans and proposal to dose record per patient in a radiology information system

Correia, Paula Duarte 21 November 2016 (has links)
A necessidade de estimar a dose efetiva de radiação recebida pelos pacientes em exames de tomografia computadorizada (TC) é muito discutida atualmente devido ao fato de que este exame está entre aqueles que mais depositam dose em pacientes submetidos a exames radiológicos. O objetivo deste trabalho foi implementar um método de estimativa de dose efetiva em exames de TC baseado em evidências bem estabelecidas e em informações contidas nas imagens. Após dosimetria realizada no equipamento de TC, mapeamento dos protocolos e definição dos fatores de correção a serem utilizados, uma rotina de processamento dos dados foi criada para conversão da informação do cabeçalho DICOM da imagem radiológica em dose efetiva estimada, de modo que as informações levantadas poderão ser disponibilizadas, em registro no sistema de informação de radiologia do Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo - HCFMRP/USP, aos médicos e profissionais de saúde envolvidos. / Computed tomography scan is the procedure that most deposits radiation dose in patients undergoing radiologic examinations. That is the reason why the need to record the dose received is currently discussed. The aim of this study was to implement an method to estimate effective dose received in CT scans based on well-established evidences and information contained in images. After performing dosimetry in CT equipment, mapped protocols and define correction factors, a data processing routine was created for conversion of DICOM header information in estimated effective dose, so that the information raised could be avalable in Hospital\'s radiology information system for doctors and health professionals involved.
160

Avaliação da radioatividade natural em algumas rochas graníticas do Estado do Paraná e sua utilização na construção civil / Evaluation of natural radioactivity in some granitic rocks in the state of Paraná and its use in civil construction

Ferreira, Ademar de Oliveira 25 March 2013 (has links)
Os radionuclídeos naturais de origem primordial, ou terrestres, são encontrados em quantidades variadas em todo meio ambiente. Nas residências, um importante incremento de dose (INDOOR), é devido aos materiais de construção, que contribuem tanto com a dose externa gama, proveniente das séries do 238U, 235U e 232Th e do radionuclídeo isolado 40K, quanto com a dose interna que é devida principalmente à inalação do 222Rn. Uma vez que rochas graníticas são amplamente utilizadas como materiais de construção, tanto estruturais como de revestimento, estas podem tornar-se uma importante fonte de dose, dependendo das concentrações de radioatividade que apresentem, e da forma e quantidade que são aplicadas nas construções. Neste trabalho foi gerado um banco de dados para rochas graníticas do escudo cristalino paranaense (principalmente da Região Metropolitana de Curitiba, RMC), que são utilizadas na construção civil avaliando em termos de proteção radiológica o incremento da dose, externa e interna, causada pela utilização destes materiais. Também foram estudadas as possíveis correlações entre a concentração de atividade de 226Ra, taxa de exalação de 222Rn, densidade, porosidade e composição química (teor de óxidos constituintes) nestas amostras. A dose externa foi avaliada por meio da técnica de espectrometria gama com detector de germânio hiperpuro, onde as concentrações de atividade dos radionuclídeos 226Ra, 232Th e 40K são os parâmetros utilizados em modelos dosimétricos (Índices Dosimétricos), os quais estabelecem limites máximos permitidos de acordo com forma, quantidade e aplicação do material de construção. Para o cálculo da dose efetiva anual externa foi adotado o modelo de sala com dimensões 4 m x 5 m x 2,8 m e todas as paredes são revestidas internamente com granitos de espessura de 2 cm e considerando o tempo de exposição anual de 7000 h, conforme sugerido pela Comissão Européia de Proteção Radiológica para materiais de revestimento interno supercial. A exposição interna foi avaliada a partir da concentração de radônio no ar da sala modelo, simulada a partir do valor da taxa de exalação supercial de 222Rn. A taxa de exalação foi determinada pela técnica de detecção passiva utilizando detectores sólidos de traços nucleares (CR-39) por meio da técnica do recipiente selado, considerando taxa de ventilação de 0,5 h-1 e tempo de exposição anual de 7000 h . Os resultados destes estudos mostram que o incremento da dose efetiva anual externa variou de (62 ± 3) μSv.a-1 a (138 ± 1) μSv.a-1 e o incremento da dose efetiva anual interna variou de (0,39 ± 0,04) μSv.a-1 a (70 ± 4) μSv.a-1. Estes valores estão abaixo do limite máximo de 1 mSv.a-1 sugerido pela Comissão Européia de Proteção Radiológica, portanto os granitos avaliados neste trabalho podem ser utilizados sem implicações radiológicas desde que obedecido o cenário descrito. Os valores obtidos para a contribuição devida à dose interna variaram de 1 % a 78 % dos valores obtidos para a respectiva dose externa, mostrando que a contribuição do radônio varia fortemente com o tipo da rocha. Os resultados das correlações entre taxa de exalação supercial de 222Rn, concentração de atividade de 226Ra, densidade, porosidade e principais óxidos componentes das amostras, mostraram que, em termos de inuência na fração de emanação do radônio, o parâmetro mais importante é a densidade, devido a baixa porosidade e a semelhança em termos de composição química entre as amostras. / Primordial, or terrestrial natural radionuclides, are found in dierent amounts in the environment. In dwellings, an important dose increment is due to building materials, which contribute for both the external gamma dose from the radionuclides of the 238U, 235U and 232Th series and the natural 40K and the internal dose, due mainly to 222Rn inhalation. Once granitic rocks are widely used both as construction materials or structural flooring, those rocks can become an important dose source, depending on the content of concentrations of radioactivity, and the construction application. In this work, a database for granitic rocks of the crystalline shield of Paraná (mainly in the Metropolitan Region of Curitiba, RMC), used in civil construction, was generated, evaluating in terms of radiological protection the external and internal dose increments, caused by the use of these materials. Also, possible correlations between the 226Ra activity concentration, the 222Rn exhalation rate, density, porosity and chemical composition (oxide content) in these samples had been studied. The external dose was assessed by gamma-ray spectrometry with High-Purity Germanium detectors, where the activity concentration of the radionuclides 232Th, 226Ra and 40K are the parameters used in dosimetric models (Dosimetric Indexes), which established limits in accordance with the form, amount and application of material of construction. For the calculation of the annual eective external dose it was assumed a room model with dimensions of 4 m x 5 m x 2.8 m and all walls internally covered with 2 cm thickness of granite and an annual exposure time of 7000 h as suggested by the European Commission of Radiological Protection for internal supercial coating materials. The internal exposure was assessed from the radon concentration in the air of the room model, simulated from the supercial exhalation rate of 222Rn. The exhalation rate was determined by the passive detection technique with the Solid State Nuclear Track Detectors (CR-39) and the sealed can technique, assuming a ventilation rate of 0.5 h-1 and an annual exposure time of 7000 h. The results for this studies show that the annual eective dose ranged from (62 ± 3) μSv.y1 to (138 ± 1) μSv.y-1 and the internal annual eective dose ranged from (0,39 ± 0,04) μSv.y-1 to (70 ± 4) μSv.y-1. These values are below the maximum limit of 1 mSv.y-1 suggested by the European Commission of Radiological Protection, meaning that the granitic rocks evaluated can be used without radiological implications since the considered scenario is obeyed. The values obtained for the contribution due to the internal dose ranged from 1 % to 78 % of the values obtained for the respective external dose showing the radon contribution varies strongly with the rock type. The results of the correlations between 222Rn supercial exhalation rate, 226Ra activity concentration, density, porosity and major oxides of the samples, showed that, in terms of inuence in the emanation fraction of radon, the most important parameter is the density, due to low porosity and similarity in terms of chemical composition amid the studied samples.

Page generated in 0.0474 seconds