• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 4
  • 1
  • Tagged with
  • 10
  • 10
  • 6
  • 6
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Etude expérimentale des transferts de chaleur dans un outillage : refroidissement par un écoulement diphasique / Experimental study of heat transfers in an industrial tool : two-phase flow cooling

Tymen, Gwenc'hlan 13 December 2017 (has links)
Les presses hydrauliques à compression sont utilisées afin de mettre en oeuvre des thermoplastiques. La maîtrise des champs thermiques à la surface des plateaux de presse est essentielle pour garantir une transformation de qualité des matériaux. La mise en forme des composites dits « haute performance » met en jeu d’importants transferts thermiques au niveau du plateau : montée en température jusqu’à 450 °C par résistances électriques, puis refroidissement par écoulement d’eau au sein de canaux cylindriques. L’apparition de phénomènes d’ébullition convective liés aux niveaux de température mis en jeu rend délicate la maîtrise des vitesses de refroidissement lors du procédé. L’objectif des travaux présentés dans ce manuscrit est d’étudier la phase de refroidissement à l’eau de plateaux de presse, dans des conditions représentatives du procédé industriel. Deux configurations expérimentales sont retenues. Dans un premier temps, l’étude se concentre sur l’analyse de l’écoulement diphasique eau-vapeur dans un canal horizontal. Une caméra rapide permet d’observer les régimes d’écoulements apparaissant dans un canal en quartz. Puis, l’évolution des champs thermiques le long d’un canal en acier inoxydable est menée, à l’aide d’une instrumentation thermique fine, dont notamment un capteur intrusif mobile spécialement conçu pour mesurer la température au coeur de l’écoulement. Dans un deuxième temps, l’étude est menée sur un élément de plateau de presse, système plus représentatif de la réalité industrielle. Plusieurs essais expérimentaux sont menés afin de quantifier l’influence du débit d’eau et de la température initiale sur la vitesse de refroidissement. Un modèle numérique vient en appui de l’analyse des résultats expérimentaux pour aider à la compréhension des phénomènes. Enfin, le montage expérimental est modifié, afin d’optimiser le refroidissement du plateau et respecter une vitesse de descente en surface de 25 °C.min-1 et ouvrir des perspectives en terme de régulation du procédé. / Hydraulic press are used to develop thermoplastic materials. The control of the thermal fields at the surface of the press platens are essential to ensure a good-quality transformation. The forming of “high performance” composites is realized within high temperature levels : heating to 450°C, with electrical cartridge ; cooling, with a water flow inside cylindrical channels. The incipience of flow boiling, due to high temperature, makes the control of cooling rate difficult during the process. The goal of the works presented here is to study the cooling process of the platen, in industrial conditions. Two experimental setups are tested. On the one hand, the study focuses on the analysis of the two-phase flow boiling. A high-speed camera enables the different flow regimes to be observed in a quartz channel. Then, the evolution of the thermal fields along a stainless steel channel is led, thanks to a fine thermal instrumentation, including an intrusive mobile sensor which has been especially made to measure the flow temperature. On the other hand, the study focuses on a single part of a platen, which is more representative of the industrial conditions. Several tests are led in order to quantify the influence of the water flowrate and the initial temperature level on the cooling rate. In parallel, a numerical model is developed to comprehensively understand the phenomenon. Finally, the experimental test bench is modified to improve the cooling of the platen and to control a 25°C.min-1 cooling rate, in the purpose of finding some perspectives concerning the process regulation.
2

Contribution à l'étude phénoménologique de l'ébullition convective en mini-canal / Contribution to phenomenological study of flow boiling in mini-channel

Layssac, Thibault 09 February 2018 (has links)
Les écoulements diphasiques liquide-gaz et liquide-vapeur sont présents dans de nombreuses problématiques industrielles. De fait, ils sont rencontrés dans des configurations diverses, tant en termes de dimensions que d’orientation et présentent des caractéristiques variées. Pour autant, il peut être distingué dans la littérature deux cas limites de modélisation de l’écoulement diphasique liées à son confinement : l’échelle micro et l’échelle macro. Cependant, la caractérisation de la transition entre ces deux échelles reste un enjeu majeur de compréhension de l’écoulement diphasique. De plus, les comportements thermiques en ébullition convective sont impactés par le phénomène de nucléation, fortement influencé par la géométrie de l’application et les conditions de saturations. De ce fait, l’objectif principal de la thèse est de contribuer à la compréhension des écoulements diphasiques adiabatiques et non adiabatiques à une échelle intermédiaire entre les échelles micro et macro, où les comportements tant dynamiques que thermiques sont mal définis. Pour ce faire, dans le travail présent, les effets du confinement et de l’inclinaison de l’écoulement diphasique sur les régimes d’écoulement, les chutes de pression et les échanges thermiques sont étudiés et comparés avec les observations et modèles de la littérature. Une section test inclinable de 1,6 mm de diamètre intérieur a été installée sur le banc d’essais de Charnay (2014), permettant l’étude de l’ébullition convective du R-245fa. Celle-ci permet de visualiser l’écoulement à l’intérieur de l’évaporateur ainsi que d’acquérir simultanément les chutes de pression et le champ de température de paroi extérieure. Pour ce faire, un tube en saphir chauffé par un dépôt d’ITO a été employé. Le champ de température a été obtenu par une procédure d’acquisition et de post-traitement infrarouge. Au préalable, une campagne d’essais a été menée en conditions adiabatiques sur la section de Charnay (2014). La section test présente, quant à elle, a permis deux campagnes d’essais en conditions adiabatiques et en ébullition convective. Des études menées en conditions adiabatiques est apparu un fort effet de l’inclinaison et du confinement sur les régimes d’écoulement ainsi que sur les chutes de pression. L’effet de l’inclinaison s’apparente à ce qui a pu être observé en macro-canal dans la littérature. De plus, l’inclinaison n’affecte que peu les échanges thermiques au regard des incertitudes inhérentes au dispositif infrarouge. Enfin, il est observé un effet de l’inclinaison sur le régime d’assèchement. Dans cette configuration, l’évolution temporelle du champ de température de paroi extérieure apparaît synchrone avec l’évolution dynamique de l’écoulement diphasique. / Liquid-gas and liquid-vapour two-phase flows are encountered in a large range of industrial applications. They are observed in multiple configurations, in terms of dimension and orientation and then have various characteristics. In the literature, it can be distinguished two limit cases of the two-phase flow linked to its confinement: micro and macro-scale. Nonetheless, characterisation of the micro-to-macro scale transition is still a main issue for the comprehension of two-phase flow. In addition, thermal behaviours of flow boiling are affected by the nucleation phenomenon, which is strongly influenced by the geometry of the application and the saturation conditions. The main objective of the thesis is to contribute to the comprehension of adiabatic and diabatic two-phase flows in mini-scale, where the general behaviours are not well definite. In the present study, the effects of confinement and orientation of two-phase flows on flow patterns, pressure drops and heat exchanges are studied and compared with observations and models of the literature. An 1.6 mm inner diameter inclinable test section was installed on the test bench of Charnay (2014), which enabled to study R-245fa flow boiling. This test section enables to visualize the flow directly in the evaporator and the simultaneous acquisition of the pressure drops and the outside wall temperature field. A sapphire tube, heated by a transparent ITO coating, is unemployed to insure the transparency. The temperature field is obtained by an IR image processing. Previously, tests were led on the section of Charnay (2014) in adiabatic conditions. The present test section was used for two series of tests, led in both adiabatic and diabatic conditions. It appeared a strong effect of confinement and orientation on the flow patterns and pressure drops. The effect of the orientation is likely the same that one observed in macro-scale. In addition, the orientation slightly affects heat exchanges in comparison with the uncertainties of the IR dispositive. Finally, it is observed an effect of orientation on dryout flow pattern. In this configuration, the temperature field evolution with time is synchronized with the dynamic evolution of the two-phase flow.
3

Dynamics and Transfers in two phase flows with phase change in normal and microgravity conditions / Dynamiques et Transferts dans les écoulements diphasiques avec changements de phase en gravité normal et microgravité

Trejo Peimbert, Esli 22 November 2018 (has links)
Les écoulements diphasiques avec ou sans changement de phase sont présents dans les applications terrestres et spatiales avec notamment le contrôle thermique des satellites par boucle diphasique, l’alimentation en propergol des moteurs de fusée et le traitement des eaux usées pour les missions d’exploration spatiale. Des expériences d’ébullition convective dans un tube chauffé avec du HFE7000 ont été menées en écoulement vertical ascendant au sol et en microgravité conditions afin de caractériser les régimes d’écoulements et de mesurer les transferts de chaleur, le taux de vide et les pertes de pression. Les mesures de taux de vide ont permis de caractériser la vitesse moyenne de la phase vapeur et l’épaisseur du film liquide en écoulement annulaire. En microgravité, l’épaisseur du film liquide et le frottement interfacial sont inférieurs aux conditions de gravité terrestre. La structure du film liquide a été caractérisée par des visualisation rapides. L’impact de la gravité, des vitesses superficielles du liquide et de la vapeur sur la célérité et la fréquence des ondes perturbatrices a été mis en évidence. Deux techniques de mesure ont été implémentées et comparées pour la mesure du coefficient d’échange de chaleur. En ébullition convective saturée pour des titres massiques supérieurs à 0.2, le transfert de chaleur est peu sensible à la gravité et en bon accord avec des corrélations de la littérature. En ébullition nucléée sous refroidie pour des titres inférieurs à 0.1, le transfert de chaleur est significativement plus faible en microgravité. / Two-phase flows with or without phase change are present in terrestrial and space applications like thermal control of satellites, propellant supply for launchers, and waste water treatment for space exploration missions. Flow boiling experiment with HFE7000 were conducted in a heated tube in vertical upward flow on ground and in microgravity conditions to collect data on flow patterns, pressure drops, heat transfers, void fraction. Void fraction measurements allowed to measure mean gas velocity and the liquid film thickness in annular flow. In microgravity condition, the liquid film thickness and the interfacial shear stress are significantly lower than in normal gravity. A detail analysis of the film structure was performed by image processing. The impact of gravity and liquid and vapour superficial velocities on the disturbance waves velocities and frequencies was investigated. Two different measurement techniques were used and compared to determine the heat transfer coefficient. For quality values greater than 0.2, HTC is not sensitive to gravity and is in good agreement with classical correlations of the literature. For qualities smaller than 0.1, in the subcooled nucleate boiling regime HTC is significantly smaller in microgravityconditions.
4

Influence de la pesanteur lors des transferts de chaleur et de masse par ébullition et évaporation

Brutin, David 08 December 2009 (has links) (PDF)
Les travaux présentés dans ce mémoire de HDR sont la synthèse de six années de recherche sur l'influence de la pesanteur lors des transferts de chaleur et de masse par ébullition et évaporation. Dans le premier chapitre de ce mémoire, je présente une synthèse de la littérature depuis 2003 sur mes activités de recherche. Je mets l'accent sur les techniques employées et les approches choisies pour comprendre les phénomènes physiques rencontrés que ce soit en évaporation ou en ébullition. A la fin de chaque section de ce chapitre, je fais le point sur notre positionnement par rapport à ces activités, je retrace le cheminement qui nous amenes à développer les méthodes inverses en conduction de la chaleur appliquées à l'ébullition convective, ou à développer l'imagerie infrarouge aux gouttes en évaporation. Dans le second chapitre de ce mémoire, je détaille les travaux effectués en présentant de manière synthétique les méthodes et outils ainsi que les résultats obtenus. Il ne s'agit pas dans ce chapitre de s'appesantir sur les détails techniques de construction des expériences qui ont déjà été publiés dans les articles en annexe. Dans le troisième chapitre de ce mémoire qui est divisé en deux sections distinctes, je présente dans un premier temps les projets acceptés qui vont démarrer dans les mois à venir. Dans un second temps, je présente des perspectives de recherche au travers de proposition de recherche qui déjà fait l'objet de demande de financement.
5

Ecoulements liquides en microtubes et ébullition convective en minicanaux : étude expérimentale et modélisation

Brutin, David 22 October 2003 (has links) (PDF)
L'étude ici développée traite de deux aspects de la microfluidique : l'hydrodynamique d'écoulements liquides en microtubes et l'ébullition convective en minicanaux. Le dispositif et la méthode de traitement développés dans la première partie du mémoire permettent d'obtenir le nombre de Poiseuille d'écoulements laminaires liquides avec une précision inférieure à 4%. L'étude met en évidence une croissance du nombre de Poiseuille pour les écoulements d'eau distillée, d'eau de ville et des solutions de KCl au sein de microtubes en silice de diamètres allant de 540 à 52 µm. L'origine des écarts à la théorie classique en macroconduites a été recherchée. Une des hypothèses vraisemblable est l'effet de la Double Couche Electrique due aux ions contenus dans le fluide et à la surface interne du microtube chargée électrostatiquement. Dans la seconde partie du manuscrit, nous mettons en évidence l'influence du confinement pariétal sur un écoulement avec changement de phase liquide-vapeur au sein d'un minicanal vertical. Deux régimes d'ébullition sont observés : stationnaire avec des structures d'écoulements classiques et instationnaires dues à une production importante de vapeur. Dans ce dernier cas, nous distinguons les fluctuations de couplage et les fluctuations intrinsèques à l'écoulement confiné. Un critère de déclenchement des instationarités permet d'accéder à une grandeur adimensionnelle. Une loi d'échelle est alors proposée pour les écoulements diphasiques dans les minicanaux. Il en est de même pour les transferts thermiques.
6

Bubble dynamics and boiling heat transfer : a study in the absence and in the presence of electric fields / Dynamique de bulles et transfert thermiques par ébullition : étude en absence et en présence de champs électriques

Siedel, Samuel 13 April 2012 (has links)
L’ébullition est un mode de transfert de chaleur très efficace utilisé dans de nombreux systèmes technologiques comme les centrales nucléaires ou refroidissement de micro-électronique. La prédiction des échanges thermiques par ébullition reste actuellement très délicate, en raison de la complexité du phénomène, malgré des décennies de recherche sur le sujet. Le coefficient de transfert thermique est intimement lié à la dynamique de bulles (nucléation des bulles, croissance et détachement) ainsi qu’à des facteurs tels la densité de sites de nucléation ou les interactions entre bulles voisines et successives. La présente étude porte sur l’ébullition saturée sur un site de nucléation artificiel unique (ou deux sites voisins) sur une paroi en cuivre poli. La dynamique de croissance des bulles a été caractérisée pour différentes surchauffes de paroi et une loi expérimentale de croissance a été établie. Les interactions entre bulles successives issues du même site ont été étudiées, montrant qu’elles peuvent provoquer des oscillations de la bulle en croissance. Les forces agissant sur une bulle en croissance ont été clairement définies, et un bilan de quantité de mouvement a été réalisé à tous les stades de la croissance d’une bulle. La courbure le long de l’interface a été mesurée, ce qui a permis de mieux saisir le mécanisme de détachement de la bulle. L’ascension d’une bulle après son détachement a été analysée, et la vitesse maximale atteinte avant un changement de direction a été estimée et comparée aux modèles existants dans la littérature. L’interaction entre bulles croissant côte à côte a été étudiée. La génération et la propagation d’une onde lors de la coalescence a été mise en évidence. Dans le contexte de travaux de recherche sur des techniques d’intensification des échanges thermiques, cette étude se penche particulièrement sur l’intensification par électrohydrodynamique. Des expériences d’ébullition ont été réalisées en présence de champs électriques, et leurs effets sur les transferts thermiques et sur la dynamique des bulles ont été analysés. Bien que le volume au détachement des bulles et la relation entre la fréquence et la surchauffe reste inchangées, la courbe de croissance des bulles est modifiée. Les bulles sont allongées dans la direction du champ électrique, et cette élongation a été estimée et comparée à d’autres résultats de la littérature. La vitesse d’ascension des bulles est réduite en présence de champs électriques, et les interactions de bulles voisines sont modifiées: il s’avère qu’en présence de champs électriques les bulles ont tendance à se repousser. Ces résultats, obtenus dans un environnement parfaitement contrôlé apportent la preuve que la présence de champs électriques modifie la dynamique des bulles et par conséquents les transferts thermiques associés. / Since boiling heat transfer affords a very effective means to transfer heat, it is implemented in numerous technologies and industries ranging from large power generation plants to micro-electronic thermal management. Although having been a subject of research for several decades, an accurate prediction of boiling heat transfer is still challenging due to the complexity of the coupled mechanisms involved. It appears that the boiling heat transfer coefficient is intimately related to bubble dynamics (i.e. bubble nucleation, growth and detachment) as well as factors such as nucleation site density and interaction between neighbouring and successive bubbles. In order to contribute to the understanding of the boiling phenomenon, an experimental investigation of saturated pool boiling from a single or two neighbouring artificial nucleation sites on a polished copper surface has been performed. The bubble growth dynamics has been characterized for different wall superheats and a experimental growth law has been established. The interaction between successive bubbles from the same nucleation site has been studied, showing the bubble shape oscillations that can be caused by these interactions. The forces acting on a growing bubble has been reviewed, and a complete momentum balance has been made for all stages of bubble growth. The curvature along the interface has been measured, and indications concerning the mechanism of bubble detachment have been suggested. The rise of bubble after detachment has been investigated, and the maximum velocity reached before a change of direction has been estimated and compared to existing models from the literature. The interaction between bubbles growing side by side has been studied: the generation and propagation of a wave front during the coalescence of two bubbles has been highlighted. As boiling heat transfer enhancement techniques are being imagined and developed, this study also focuses on the electrohydrodynamic enhancement technique. Boiling experiments have been performed in the presence of electric fields, and their effects on heat transfer and bubble dynamics have been characterized. Although the volume of the bubbles at detachment and the relationship between the bubble frequency and the wall superheat were not affected, the bubble growth curve was modified. The bubbles were elongated in the direction of the electric field, and this elongation was estimated and compared to other studies from the literature. The rising velocity of the bubble was reduced in the presence of electric field, and the behaviour of bubbles growing side by side was modified, the electric field causing the bubbles to repeal each other. These results, obtained in a fully controlled environment, provide compelling evidence that electric fields can be implemented to alter the bubble dynamics and subsequently heat transfer rates during boiling of dielectric fluids.
7

Ebullition nucléée sur des surfaces ultra-polies : Influence de la topographie et du revêtement sur le phénomène de nucléation / Nucleate boiling on ultra-smooth surfaces : Influence of topography and coating on the nucleation phenomenon

Al Masri, Mostafa 07 July 2017 (has links)
Une étude expérimentale est menée afin de comprendre le phénomène de nucléation lors de l'ébullition. Cette étude est menée sur des surfaces polies miroir ou ultra-polies en aluminium, l’acétone étant le fluide de travail. L'analyse est réalisée en fonction de la topographie de la surface liée au degré de polissage et en fonction du revêtement de la surface dans le but de modifier sa mouillabilité. L’étude a mis en avant trois catégories de comportement, fonctions de l’état de surface : les surfaces nano lisses, les surfaces nano lisses avec défauts et les surfaces rugueuses. Les bonnes caractéristiques obtenues avec des échantillons nano lisses comportant des défauts aléatoirement répartis ont conduit à la réalisation d’échantillons nano lisses avec des défauts de position et de taille contrôlés. Les résultats obtenus avec ces derniers échantillons présentent les meilleures performances. Une amélioration supérieure à un facteur deux par rapport aux surfaces rugueuses est observée, ce qui représente un gain substantiel. Bien qu’il soit le fondement de la plupart des modèles théoriques, le nucléus à l’origine de la formation d’une bulle n’a jamais été observé expérimentalement car sa taille dépasse la capacité des moyens de mesure traditionnels. Dans ce mémoire, une méthode optique - basée sur la résonnance de plasmons sur des surfaces comportant un réseau de diffraction - est utilisée dans le but d’étudier ce phénomène. Les expériences mettent en évidence la capacité de cette méthode à mesurer la variation de la température pariétale de l’échantillon avant le déclenchement de l’ébullition. Les mesures de résonance plasmon montrent qu’il n’y a pas de modification de la densité du fluide au voisinage de la paroi pour des surchauffes proches du déclenchement de l’ébullition. La nucléation est trop rapide pour être mesurée. Cependant, des premiers nuclei de condensation ont été détectés par cette méthode, ce qui constitue un résultat très prometteur. / An experimental study was conducted in order to understand the phenomenon of nucleation in boiling. This study was done on smooth surface or ultra-smooth surface made of aluminum, the working fluid is acetone. The analysis was realized as a function of the topography of the sample, roughness level, and as a function of nanocoating of the surface in order to modify the wettability. The study classed the sample in three categories, depending on the surface condition: the ultra-smooth surface, the ultra-smooth surface with defect and the rough surface. The good characteristics were obtained for the ultra-smooth sample with randomly distributed defects led to the fabrication of ultra-smooth sample with controlled artificial cavity. The results obtained with these latter samples present the best performances. A two-fold improvement over rough surfaces is observed, representing a substantial gain. Although it is the foundation of most theoretical models, the nucleus at the origin of the formation of a bubble has never been observed experimentally because its size exceeds the capacity of the traditional means of measurement. In this memory, an optical method - based on the resonance of plasmons on surfaces with a diffraction grating - is used to study this phenomenon. The experiments demonstrate the ability of this method to measure the temperature variation in the wall of the sample before boiling. Plasmon resonance measurements show that there is no change in the density of the fluid near the wall for overheating close to the boiling point. The nucleation is too fast to be measured. However, first nuclei of condensation were detected by this method, which is a very promising result.
8

Experimental study of third (HFC) and fourth generation (HFO) refrigerants during flow boiling in singularities / Etude expérimentale de la troisième (HFC) et quatrième génération (HFO) frigorigènes lors de l'écoulement bouillant dans les singularités

Padilla Gomez, Miguel David 18 November 2011 (has links)
La réduction de charge de fluides frigorigènes dans les systèmes de production de froid est un enjeu important s'inscrivant dans les politiques environnementales sur la contribution de ces fluides à l'effet de serre. Une des voies menant à la réduction de charge est l'augmentation de la compacité des échangeurs de chaleur, conduisant inévitablement à la conception d'évaporateurs plus complexes. Néanmoins, si de nombreuses études ont été publiées sur l'analyse thermo-hydraulique de l'ébullition convective de frigorigènes dans les tubes horizontaux, très peu ont été menées sur des écoulements diphasiques dans des géométries non conventionnelles. Cette thèse vise à étudier les caractéristiques des écoulements diphasiques avec changement de phase des frigorigènes de troisième (HFC) et de quatrième génération tels que le HFO-1234yf dans des singularités (coudes de retour, contractions). Ainsi, un banc d'essais expérimental a été spécifiquement conçu et construit pour mener des expériences sur l'ebullition convective. Ce banc d'essais a permis de visualiser les régimes d'écoulement et de mesurer les chutes de pression dans les singularités. Des visualisations de régimes d'écoulement ont été réalisées pour les frigorigènes HFO-1234yf, R-134a et R-410A dans des tubes droits et dans des singularités. Les résultats ont été confrontés avec diverses méthodes de prédiction de la litérature. Les perturbations sur l'écoulement causées par ces singularités et leurs effets sur le comportement hydrodynamique des fluides frigorigènes ont également été etudiés. Une serie d'éxperience a été menée pour déterminer le longueur de perturbation en amont et en aval des singularités. Finalement, les valeurs expérimentales des chutes de pression ont été confrontées à différentes corrélations de la littérature. Des nouvelles méthodes de prédiction de la chute de pression pour des écoulements diphasiques dans des singularités sont présentées. / The refrigerant charge reduction in HVAC\R systems is an important issue because it falls within environmental policies regarding refrigerants contributions to the greenhouse effect. A way to move toward charge reduction is to increase the compactness of heat exchangers, which means more complex designs of the evaporators. Nevertheless, while a large amount of studies have has been published on the thermal and hydraulic analysis of flow boiling of refrigerants in horizontal tubes, very little attention has been given to flow boiling in geometries different from straight tubes. This PhD thesis aims at studying the flow boiling characteristics of third generation (HFC) and fourth generation fluids such as HFO-1234yf in geometries which modify the fluid dynamics and two-phase flow with respect to horizontal straight tubes. To achieve this goal, an experimental test facility was specifically designed and built to conduct refrigerant evaporation experiments. This test facility allowed to perform flow regimes visualizations and pressure drop measurements in singularities (such as sudden contractions and return bends). First, two-phase flow regimes visualizations have been carried out using HFO-1234yf, R-134a and R-410A either in straight tubes or in singularities. A qualitative analysis of the flow behavior and also several comparisons to flow pattern prediction methods from the literature were conducted. The second objective of this work was to characterize the flow disturbances caused by singularities such as sudden contractions and return bends, and to study their effects on the hydrodynamic performance (e.g. pressure drop) of refrigerants.Lastly, pressure drop databases for third and fourth generation refrigerants are presented.
9

Ebuliçao Convectiva do R-134a em microcanais paralelos e analise da distribuicao do escoamento bifasico ar-agua en um distribuidor acoplado a microcanais.

Dario, Evandro rodrigo 06 December 2013 (has links)
Les échangeurs de chaleur constitués de microcanaux parallèles sont considérés une bonne solution technologique pour dissiper de grands flux de chaleur dans les composants et les systèmes miniaturisés. D’une manière générale cette réduction de taille permet une diminution des coûts des matériaux et l'utilisation de plus faible quantité de fluides frigorigènes pour les systèmes de refroidissement. Cette étude est divisée en deux parties complémentaires A et B. Elles visent à étudier le comportement thermo-hydraulique dans les échangeurs de chaleur constitués de microcanaux pour une meilleure compréhension des transferts de chaleur et des écoulements diphasiques dans les évaporateurs miniatures. Dans la partie A, nous étudions l'ébullition convective du réfrigérant R134a dans un mini échangeur composé de neuf microcanaux parallèles de section transversale circulaire, placés horizontalement, avec un diamètre interne de 0,77 mm et longueur et 150 mm. Les résultats expérimentaux montrent que la configuration d'écoulement a une forte influence sur le coefficient de transfert de chaleur, et que différents mécanismes de transfert de chaleur ont lieu dans chacune de ces configurations d'écoulement. En revanche la perte de pression est une fonction directe de la vitesse massique, du titre de vapeur et de la pression du système. La partie B, porte sur l’analyse de la distribution de l'écoulement diphasique en l’absence de transferts de chaleur et de changement de phase liquide-vapeur. A partir de ces résultats nous montrons que les effets du titre de gaz sur la répartition du liquide change considérablement selon la position de l'ensemble (tube d'alimentation, distributeur-canaux). / Heat exchangers consisting of parallel micro-channels are considered a good technological solution in response to the increasing demand for compact systems, which require high heat flux dissipation, ensuring a decrease in the material costs and the use of a lower quantity of refrigerants. The aim of this study was to investigate the thermo-hydraulic behavior inside these components provided by microchannels. This study is divided into two experimental studies (A and B) which are complementary. In part A, the convective boiling of the refrigerant R134a is analyzed within nine parallel microchannels of circular cross section, positioned horizontally, with internal diameter and length of 0.77 mm and 150 mm, respectively. The experimental results show that the flow pattern has a strong influence on the heat transfer coefficient, and that different heat transfer mechanisms are associated with each of the flow patterns observed, whereas the frictional pressure drop is a direct function of the mass velocity, vapor quality and pressure of the system. In part B, the two-phase flow distribution, using as the working fluid a mixture of air and water, is analyzed inside a circular header coupled to nine branched parallel microchannels of circular cross-section with internal diameter and length of 0.8 mm and 150 mm, respectively. The results show that the effect of the gas quality on the liquid distribution changes considerably depending on the configuration (feeder tube-header-channels).
10

Experimental study of flow boiling in horizontal minichannels at high saturation temperature / Etude expérimentale de l'ébullition convective dans des mini-canaux horizontaux à hautes températures de saturation

Charnay, Romain 18 February 2014 (has links)
La valorisation de l'énergie thermique contenue dans des gaz chauds pour produire de l'électricité est possible grâce à l'utilisation de cycles thermodynamiques, parmi lesquels le cycle de Rankine mérite d'être considéré. Cependant, l'industrialisation d'un tel système passe par une connaissance approfondie du comportement thermohydraulique du fluide actif. Ceci permettra d'améliorer le design des principaux composants du système, spécialement les échangeurs de chaleur. Dans le cas du cycle organique de Rankine, les conditions thermodynamiques du fluide sont éloignées des conditions usuelles rencontrées dans les domaines de la climatisation ou de la réfrigération. En effet, le fluide est mis en œuvre dans des conditions proches de son point critique. La température des gaz d'échappement varie entre 400°C et 900°C et l'évaporation se produit à une température de saturation supérieure à 100°C. En ce qui concerne les caractéristiques des écoulements diphasiques (chute de pression, coefficient de transferts thermiques, régimes d'écoulement), la quasi-totalité des méthodes de prédiction a été développée pour des températures comprises entre -20°C et 40°C correspondantes aux domaines de la climatisation ou de la réfrigération. C'est pourquoi la fiabilité de ces modèles reste incertaine dans les conditions d'évaporation du cycle de Rankine, car leur utilisation est limitée par la base de données à partir de laquelle ils ont été établis et ne peuvent être extrapolés avec précision. Cette thèse vise à étudier les caractéristiques thermohydrauliques du R-245fa en ébullition convective dans les conditions du cycle de Rankine. Dans un premier temps, un banc expérimental a été conçu et construit afin de réaliser des tests en ébullition convective dans un minicanal de 3.00 mm de diamètre. Ce banc expérimental permet de faire des mesures sur les régimes d'écoulement, les coefficients de transfert de chaleur et les pertes de charge par frottement. Dans un second temps, une méthode de traitement d'image a été développée afin de caractériser différents régimes d'écoulement. Cette méthode couplée à une analyse des transferts thermiques a permis d'identifier quatre principaux régimes d'écoulement. L'influence de la température de saturation sur les régimes d'écoulement et leurs transitions a été soulignée et discutée. Les caractéristiques des bulles ont également été étudiées à l'aide de cette méthode. Dans un troisième temps, une base de données expérimentale sur les coefficients de transfert de chaleur a été créée. L'influence de la température de saturation sur les mécanismes de transfert thermique a été étudiée dans ces conditions originales. Afin de tester la fiabilité des méthodes de prédiction, les résultats expérimentaux ont été confrontés à différentes méthodes. Finalement, les chutes de pressions ont été mesurées et une analyse paramétrique a été menée. Les mesures ont été confrontées aux principales méthodes disponibles dans la littérature. / Because of current environmental issues, some technologies are being developed to reduce the fuel consumption and to reduce the emissions of CO2. Energy recovery by means of Organic Rankine Cycles or Hirn Cycles recovery is one investigated track to answer these issues. At present, some systems based on Organic Rankine Cycle (ORC) are available in industry but advanced studies are needed to allow their application in the road transport industry. A better understanding of the two-phase fluid behaviour is necessary to optimize the design models of the components containing a two-phase refrigerant. For the Organic Rankine Cycle system, the thermodynamic conditions are different to standards relevant to refrigeration or air-conditioning systems. Indeed, the key characteristic of the ORC system is the evaporation saturation temperature. Exhaust gases temperature ranges from 400°C to 900°C and the refrigerant evaporation occurs at temperatures higher than 100°C. Almost all the flow boiling heat transfer models or correlations have been obtained for saturation temperatures ranging from -20°C to 40°C which correspond to standards relevant to refrigeration or air conditioning systems. The empirical models for boiling in such conditions are limited by the experimental data on which they are based, whereas analytical and theoretical approaches are needed to advanced knowledge on the behaviour of thermohydraulic two-phase refrigerant. This PhD thesis aims at studying the flow boiling characteristics of R-245fa in a 3.00 inner diameter channel in the thermodynamic conditions of the ORC system. Therefore, the saturation temperature ranged from 60°C to 120°C. To achieve this goal, an experimental test facility was designed and built to conduct refrigerant evaporation experiments. This test facility allowed to perform flow regime visualizations, pressure drop and heat transfer measurements in minichannel. First, an image processing method for two phase flow pattern characterization was developed. Based on this method and with the help of an adequate analysis of the heat transfer coefficient, the main flow regimes have been identified. The influence of saturation temperature on the flow patterns and their transitions has been highlighted. The second objective was to provide new experimental data concerning flow boiling heat transfer in minichannel. Flow boiling heat transfer coefficients at such high temperature have, so to say, almost never been reported in the open literature so far. The influence of saturation temperature on the heat transfer mechanisms has been discussed. In order to evaluate the capability of the current flow boiling prediction methods to predict the heat transfer coefficient, the comparison between experimental results and theoretical results predicted with the commonly used correlations and models were made. Lastly, pressure drop databases are presented. Experimental values of pressure drops were compared against several methods.

Page generated in 0.104 seconds