• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 411
  • 10
  • 6
  • 6
  • 6
  • 6
  • 5
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 431
  • 202
  • 103
  • 98
  • 90
  • 79
  • 78
  • 71
  • 66
  • 63
  • 51
  • 51
  • 48
  • 47
  • 43
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
291

Modelagem simplificada de reatores anaeróbios do tipo UASB.

CEZANO, Martina Tamires Lins 16 February 2016 (has links)
Submitted by Irene Nascimento (irene.kessia@ufpe.br) on 2016-09-14T18:05:23Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertacao_Martina_Cezano_Corrigida.pdf: 1969919 bytes, checksum: 1fd1af7e30056d2160f46bf6bcc78e1e (MD5) / Made available in DSpace on 2016-09-14T18:05:23Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertacao_Martina_Cezano_Corrigida.pdf: 1969919 bytes, checksum: 1fd1af7e30056d2160f46bf6bcc78e1e (MD5) Previous issue date: 2016-02-16 / O Arranjo Produtivo Local (APL) do agreste pernambucano é um polo de confecção, especializado em jeans, que conta com aproximadamente 12 mil empresas distribuídas principalmente nos municípios de Toritama, Caruaru e Santa Cruz do Capibaribe. Em Caruaru, a principal atividade têxtil é a de lavagem de jeans, em que se utiliza grande volume de água, que é acompanhado do lançamento dos efluentes nos corpos d’água da região, sem tratamento adequado. Os efluentes despejados apresentam altas concentrações de corante, provenientes da não fixação no processo de tingimento. Com a finalidade de tratar estes efluentes de forma ambientalmente mais aceitável, do que os processos físico-químicos utilizados nas lavanderias de jeans, o tratamento biológico apresenta boa capacidade de remoção de cor e matéria orgânica (em torno de 80%). Nos processos biológicos, o uso de reatores anaeróbios de fluxo ascendente e manta de lodo (UASB) têm resultado em eficiências de remoção de cor e matéria orgânica (MO) em torno de 50% e 75%, respectivamente. Com intuito de prever o comportamento da remoção de cor e matéria orgânica em reatores do tipo UASB, neste projeto foi adaptado um modelo matemático simplificado para representar o comportamento de remoção de MO. O modelo matemático foi baseado no balanço de massa considerando o reator tipo UASB formado por 4 compartimentos de mistura completa em série, com fluxo contínuo. Tanto a remoção de MO como de cor foram representadas por cinética de 1ª ordem. O método numérico utilizado foi o de Runge-Kutta de 4ª ordem, utilizando a ferramenta Matlab®. Para calibração do modelo foram utilizados dados experimentais de operação de reator tipo UASB em escala piloto, alimentado com efluente têxtil real, apresentados por Ferraz Junior (2010) e Amaral (2011). Os resultados obtidos indicaram que o modelo matemático simplificado que foi ajustado representou o comportamento do reator tipo UASB para tratamento de efluente têxtil para ambos os parâmetros, cor e de MO. / The Local Productive Arrangement (LPA) from agrest of Pernambuco is a pole of cloth confections, specialized in jeans. There are approximately 12 thousand companies distributed in the municipalities of Toritama, Caruaru, and Santa Cruz do Capibaribe in this LPA. In the city of Caruaru the main textile activity is washing jeans. This activity demands huge amount of water, which is followed by wastewater discharges in water bodies, usually without the correct treatment. The textile effluent contains high concentration of dyes, not fixed during the dyeing process at the companies. Aiming to treat these effluents in a more environmental friendly way, in comparison with the physical-chemical process used by the jean companies, the biological treatment usually presents good performance for color and organic matter removal (around 80%). For biological processes the use of anaerobic reactors like Upflow Anaerobic Sludge Blanket (UASB) has been resulting in color and organic matter (OM) removal efficiencies around 50% and 75%, respectively. Aiming to estimate the behavior for color and organic matter removal in UASB reactors, in this project we made adjustments in a simplified mathematical model to represent the behavior of organic matter. The mathematical model was based in the mass balance considering the UASB reactor composed of 4 completely mixed compartments, in continuous flux. Both OM and color removal were well represented by the first order kinetic model. The 4th order Runge-Kutta numerical model was used through Matlab® tools. The adjusted simplified model was calibrated using the experimental data from UASB reactor operation in pilot scale, fed with real textile wastewater, presented by Ferraz Junior (2010) and Amaral (2011). The results indicated that the adjusted simplified mathematical model adequately represented the behavior of the UASB reactor treating textile wastewater for both, color and OM.
292

Águas de processo da REPLAN = qualidade e aplicação de processos oxidativos avançados / Process water from a Petroleum Refinery (REPLAN) : quality and application of advanced oxidation process

Gasparini, Mirthys Cozzett 18 August 2018 (has links)
Orientadores: José Roberto Guimarães, Carlos Gomes da Nave Mendes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-18T03:12:06Z (GMT). No. of bitstreams: 1 Gasparini_MirthysCozzett_M.pdf: 1574617 bytes, checksum: 879f212f74e005fca5974d6f943a790e (MD5) Previous issue date: 2011 / Resumo: No presente trabalho foi realizada a caracterização de várias correntes de águas de processo da REPLAN (Refinaria de Paulínia), bem como a avaliação dos processos de fotólise (UV), peroxidação (H2O2), peroxidação assistida por radiação ultravioleta (H2O2/UV), reagente de Fenton (H2O2/Fe2+) e foto-Fenton (H2O2/Fe2+/UV) no tratamento de um dos efluentes, principalmente na degradação dos compostos orgânicos. Analisando-se os dados de caracterização dos diferentes efluentes foi possível sugerir alternativas de reuso no processo de refino, como também selecionar a corrente de água ácida retificada para aplicação dos processos físico-químicos de tratamento. A eficiência dos ensaios de tratabilidade foi baseada na redução da concentração do carbono orgânico dissolvido (COD). Dentre os processos estudados, os processos oxidativos avançados (POA) H2O2/UV e foto-Fenton apresentaram 95 % de eficiência após 150 minutos de ensaio. As condições ótimas foram obtidas na relação mássica COD: H2O2 de 1:7 para o processo peroxidação assistida por radiação UV, e de 1:5 e concentração de Fe2+ de 31 mg/L para o processo foto-Fenton. O efluente tratado pelo processo H2O2/UV poderia ser reutilizado como água de reposição no sistema de resfriamento, já que esta é responsável por 49 % do total de água utilizada na refinaria / Abstract: In the present study was performed the characterization of various process water from REPLAN (Paulínia Refinery) as well as an assessment of 5 processes to treat one of the effluents: photolysis (UV), peroxidation (H2O2), peroxidation assisted by ultraviolet radiation (H2O2/UV), Fenton reagent (H2O2/Fe2+) and photo-Fenton (H2O2/Fe2+/UV), in order to degrade the organic compounds. Effluents characterization results provided reuse possibilities in the process refining and also selected the stripped sour water stream for application of physical-chemical treatments. The processes efficiency was evaluated by the dissolved organic carbon (DOC) reduction. Among the processes studied, the advanced oxidation processes (AOPs) H2O2/UV and photo-Fenton reached 95 % efficiency after 150 minutes of reaction. The optimum conditions were obtained in a mass ratio COD: H2O2 of 1:7 for peroxidation assisted by UV radiation, and of 1:5 with 31 mg/L of Fe2+ for photo-Fenton. The effluent treated by AOP H2O2/UV could be reused as make-up water in cooling systems, since it is responsible for 49 % of the total water used in the refinery / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
293

Avaliação e identificação de toxicidade em efluente da fabricação de resinas de poliester / Toxicity identification evaluation of polyester resin manufacturing wastewater

Caffaro Filho, Roberto Augusto 06 May 2008 (has links)
Orientador: Lucia Regina Durrant / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-10T19:47:18Z (GMT). No. of bitstreams: 1 CaffaroFilho_RobertoAugusto_D.pdf: 3860538 bytes, checksum: 5e0a12a4a24fb8f37e470a346d8bc95a (MD5) Previous issue date: 2008 / Resumo: Os processos industriais são geradores de uma ampla variedade de contaminantes que estão presentes nas águas residuarias. A seleção de processos de tratamento baseia-se nas características do efluente a ser tratado. Neste trabalho investigou-se um efluente tóxico da fabricação de resinas de poliéster. Existem poucas informações na literatura sobre este tipo de água residuaria. Procedeu-se a caracterização do efluente, efetuando-se a avaliação e identificação de constituintes tóxicos presentes no mesmo por meio de uma abordagem orientada por toxicidade. Foi utilizado bioensaio respirometrico em lodo ativado para avaliar a toxicidade do efluente bruto. Então, foram efetuados tratamentos físicos e químicos para fracionamento do efluente, e apos cada um deles, realizou-se o mesmo bioensaio. Dessa maneira, avaliou-se qual técnica de fracionamento foi a mais efetiva na redução da toxicidade. A maior redução de toxicidade foi observada apos o fracionamento do efluente por arraste com ar em pH 11 (62,5 %). Este resultado demonstrou que uma fração significativa da toxicidade do efluente para lodos ativados era causada por compostos orgânicos volatilizados em pH 11. Isso indica que o tratamento do efluente por arraste com ar em pH básico pode ter impacto positivo em um tratamento biológico aeróbio subseqüente. Uma vez determinado o tipo de compostos no efluente que provocam efeitos tóxicos (Compostos Organicos Volateis - COVs), procedeu-se a esforços analíticos visando a identificação dos mesmos. Analises por headspace do efluente por cromatografia gasosa e espectrometria de massa identificaram a presença de aldeidos insaturados (congeneres de acroleina). Tais compostos tinham relacao direta com o efeito tóxico observado. Foram também realizados bioensaios utilizando microrganismos anaerobios. Para tanto, mediu-se o volume de gas produzido por uma biomassa anaerobia em contato com o efluente bruto e com o efluente fracionado por arraste com ar em pH 11. Não se observou redução na toxicidade do efluente mesmo com este fracionamento. Comparando-se esses resultados aos obtidos com lodo ativados, foi verificado que os compostos removidos por arraste com ar em pH 11 não apresentaram o mesmo grau de toxicidade para esta biomassa anaerobia. Tais resultados indicam que a utilização de processo de tratamento biológico anaerobio seria uma opção adequada para a condução de futuros estudos de tratabilidade deste efluente. Os resultados obtidos neste trabalho de avaliação e identificação de toxicidade em efluente da fabricação de resinas de poliéster ratificam a abordagem utilizada como uma valorosa ferramenta na caracterização de efluentes industriais tóxicos, principalmente nos casos onde não se encontram disponíveis informações especificas relacionadas ao efluente estudado / Abstract: Industrial processes generate a vast range of contaminants that are present in wastewaters. Treatment process selection is based on wastewater characteristics. In this work a toxic polyester resin manufacturing wastewater was investigated. Specific literature on this kind of wastewater is rare. The characterization of this wastewater was conducted, evaluating and identifying toxicity by applying a toxicity-oriented approach. An activated sludge respirometric bioassay was used to assess effluent toxicity. Then, physical and chemical treatments were performed for effluent fractionation. After each fractionation, the same bioassay was conducted. In this way, it was assessed which fractionation technique was the most effective in reducing effluent toxicity. The greater toxicity reduction was observed after effluent fractionation with air stripping in pH 11 (62.5 %). This result showed that a significant fraction of wastewater toxicity for activated sludge was caused by organic compounds volatilized in pH 11. This indicates that effluent treatment by air stripping in basic pH could have a positive impact in a conjugated aerobic biological treatment. Once the type of compounds causing wastewater toxicity has been determined (Volatile Organic Compounds ¿ VOCs), analytical efforts aiming the identification of these compounds were made. Wastewater headspace gas chromatographic analyses coupled with mass spectrometry identificated the presence of a,ß-unsaturated aldehydes (acrolein congeners). These compounds were directly related to the observed toxic effect. Bioassays using anaerobic microorganisms were also conducted. To that purpose, the volume of gas produced by an anaerobic biomass in contact with the baseline effluent and with the fractionated effluent by air stripping in pH 11 was measured. No toxicity reduction was observed with this fractionation. By comparing this result with the one obtained with the respirometric bioassay, it was found that the compounds removed by air stripping in pH 11 did not inhibit this kind of biomass in the same degree which they inhibited activated sludge. This indicates that the use of an anaerobic treatment process would be an adequate option for conducting future treatability studies in this wastewater. The results obtained in this research of toxicity identification evaluation of a polyester resin manufacturing effluent confirm that the toxicity-oriented approach is a valuable tool for the characterization of toxic industrial wastewaters, especially in cases when specific information related to the studied wastewater is lacking / Doutorado / Doutor em Ciência de Alimentos
294

Fotodecomposição e remoção de efluente textil usando fotocatalise com polipirrol / Photodecomposition and removal textille effluent by photocatalysis with polypyrrole

Lima, Claudinei Sousa 06 April 2015 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2015-11-30T08:24:16Z No. of bitstreams: 2 Tese - Claudinei Sousa Lima - 2015.pdf: 4697944 bytes, checksum: 7602b1a52d5ff89353f1980ba35380a6 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2015-11-30T08:26:27Z (GMT) No. of bitstreams: 2 Tese - Claudinei Sousa Lima - 2015.pdf: 4697944 bytes, checksum: 7602b1a52d5ff89353f1980ba35380a6 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-11-30T08:26:27Z (GMT). No. of bitstreams: 2 Tese - Claudinei Sousa Lima - 2015.pdf: 4697944 bytes, checksum: 7602b1a52d5ff89353f1980ba35380a6 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2015-04-06 / Fundação de Amparo à Pesquisa do Estado de Goiás - FAPEG / A real sample of textile wastewater was successfully decolorized through a simple, fast and efficient photocatalytic treatment using polypyrrole as catalyst. In the optimized operational conditions, the photocatalytic treatment resulted in 95.8% decrease in the units of color and 91.2% photodecomposition. Photocatalysis reduced the COD values from 1111.04 mg L1 to 71.43 mg L1, evidencing 93.6% reduction in the organic matter to be discharged. TOC was also efficiently reduced from 156.75 to 51.74. The efficiency of the photocatalytic process was maintained during repeated use when cycles of photocatalysis were followed by redoping of polypyrrole with 0.1 mol L1 HCl solution. The same photodecomposition efficiency was achieved using sunlight irradiation for 30 min, with values of photodecomposition up to 98%. Tests of toxicity using Artemia saline resulted in 96.7% survival, indicating that the products generated in the photodecomposition are non-toxic. Tests made with an artificial effluent showed the same efficiency in wastewater color removal indicating that the process may be suitable for treating effluents with different colors with same efficiency. In this way, photocatalytic treatment may be applied on photodecomposition of textile effluent, independent of the predominant color present in the effluent. / Uma amostra real de efluente têxtil foi descorada com sucesso através de um tratamento fotocatalítico simples, rápido e eficiente usando polipirrol como catalisador. Nas condições operacionais optimizadas, o tratamento fotocatalítico resultou em 95,8% de diminuição nas unidades de cor e 91,2% fotodecomposição. A fotocatálise reduziu os valores de Demanda Química de Oxigênio (DQO) de 1111,04 mg.L-1 para 71,43 mg.L-1, evidenciando redução de 93,6% da matéria orgânica a ser descartada nos corpos receptores. O Carbono Orgânico Total (COT) também foi reduzido de forma eficiente 156,75 - 51,74 ppm . A eficiência do processo fotocatalítico foi mantida durante o uso repetido, quando os ciclos de fotocatálise foram seguidos por redopagem do polipirrol com uma solução de HCl 0,1 mol.l-1. A mesma eficiência de fotodecomposição foi conseguida utilizando irradiação solar durante 30 minutos, com valores de fotodecomposição até 98%. Os testes de toxicidade usando Artemia salina, resultaram em 96,7% de sobrevivência, o que indica que os produtos gerados na fotodecomposição não são tóxicos. Testes feitos com o um efluente artificial mostraram a mesma eficiência na remoção da cor do efluente indicando que o processo pode ser adequado a tratar efluentes artificias que permitiriam realização de experimentos sem a interferência de variações da cor do efluente em função cor predominante produzida no dia da coleta.
295

Efeitos da AdubaÃÃo Nitrogenada sobre a produÃÃo da Mamona irrigada com Ãgua e Efluentes de Esgoto domÃstico tratado / Effect of the nitrogenada fertilization on the production of the Mamona irrigated with water and effluent of treated domestic sewer

Ãtalo Reges Neco Capistrano 16 March 2007 (has links)
FundaÃÃo Cearense de Apoio ao Desenvolvimento Cientifico e TecnolÃgico / A mamona (Ricinus communis L.), pode ser considerada uma cultura com muitas utilidades, dentre elas a de utilizar o seu Ãleo para produÃÃo de um biodiesel, combustÃvel considerado ecologicamente limpo, ou seja, pouco ou nÃo poluidor do ambiente. AlÃm de trazer benefÃcios ambientais, a exploraÃÃo da mamona possibilita, tambÃm, a geraÃÃo de emprego. No presente estudo, conduzido em um Argissolo Acinzentado eutrÃfico, no municÃpio de Aquiraz (CE), foram investigadas as respostas da mamona (variedade BRS-149, Nordestina) a crescentes doses de nitrogÃnio (0, 30, 50, 70 e 90 kg N ha-1), usando-se duas diferentes fontes de Ãgua para irrigaÃÃo: Ãgua tratada e Ãgua de poÃo oriunda de estaÃÃo de tratamento de esgoto domÃstico (efluente). O experimento foi instalado e conduzido em condiÃÃes de campo na estaÃÃo experimental da CAGECE/PROSAB/CT-UFC no municÃpio de Aquiraz-CE. A Ãrea foi dividida em duas parcelas, sendo uma irrigada com Efluente de Esgoto Tratado e a outra irrigada com Ãgua de PoÃo. O espaÃamento utilizado foi de 1m entre plantas e 3 m entre filas. O delineamento experimental utilizado foi o de parcelas subdivididas com 3 repetiÃÃes. Foram avaliados componentes de produÃÃo e de crescimento. Foram obtidas produtividades de sementes de atà 2250 kg N ha-1 na parcela com Efluente de Esgoto e 2240 kg N ha-1 na parcela irrigada com Ãgua de PoÃo. As doses que promoveram maior produtividades de sementes foram: 70 e 90kg N ha-1, para o Efluente de Esgoto Tratado e 50kg N ha-1, para a parcela irrigada com Ãgua de PoÃo. Doses crescentes de nitrogÃnio (UrÃia), provocaram efeitos diferentes nas parcelas irrigadas com Efluente de Esgoto DomÃstico e Ãgua de PoÃo. / The castor bean (Ricinus communis L.) can be considered as a commercial crop with multiple utilities, among them, the use of its seed oil for biodiesel production, a motor fuel considered ecologically clean. The present study was conducted under field conditions, in an Argissolo Acinzentado eutrophic soil, and had the objective to evaluate the castor bean yield (cultivar Nordestina BRS-149) response to nitrogen fertilization. The experimental design consisted of a split-plot model. One plot was irrigated with treated sewage effluent and the other with well water. Each plot was fertilized with five N rates in a form of Urea (T1=0, T2=30, T3=50, T4=70, T5=90 kgha-1 N), control treatment and three replications. The following parameters were evaluated: number of racemes/plant, first raceme length, 100 seed weight, kg of seed per hectare, first raceme height and stem diameter. The number of racemes/plant was significantly higher in the plot irrigated with treated sewage effluent than in the plot irrigated with well water. The type of irrigation did not cause differences in the first racemes lengths; however, differences occurred inside each plot as function of the N rate. The seed highest productivity was 2250 kgha-1 (rate of 90 kg Nha-1) for the plot irrigated with treated effluent, while was 2240 kgha-1 (rate of 50 kg Nha-1) for the plot irrigated with well water. The higher pH of the effluent may caused higher N volatilization, what may explain the higher N rate to reach maximum productivity in the effluent irrigated plot. The nitrogen fertilization caused significant increases in all parameters evaluated, except for 100 seed weight.
296

Pós-tratamento de efluentes de filtro anaeróbio precedido de tanque séptico por filtros aeróbios intermitentes de areia

Santos, Leonardo Rodrigues dos 06 November 2012 (has links)
Made available in DSpace on 2015-09-25T12:20:08Z (GMT). No. of bitstreams: 1 Leonardo Rodrigues dos Santos.pdf: 1589161 bytes, checksum: 70a093bacbb900a6535a34862626d355 (MD5) Previous issue date: 2012-11-06 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The discharging effluents in natura in soil or fresh water resources, directly or indirectly, this results beyond several problems socio environmental, in significant impacts about terrestrial and aquatic life. The absence of treatment in the efluents and your incorrect destination contribute to worsen the environment and the public health. This study aimed to evaluate the application the intermittent aerobic sand filters, as alternative system of post-treatment of effluents preceded of the septic tank and anaerobic filter, aiming the removal of nutrients, organic matter sewage from the science and technology center (STC). The university of Paraiba (UEPB) the system of pos-treatment built in the study is formed intermittent aerobic sand filters composed by three boxes of polyethylene fiber (one that acts like equalization tank and the other two act like aerobic filters.) the two aerobic sand filters (FA1 and FA2) were filed and with gravel and sand in the following proportion: 15 cm of gravel nº 3 in the base, 15 cm of gravel in the superior portion: 15 cm of gravel nº3 in the base, 30 cm of sand in the middle portion immediately above the gravel layer of the base 15 cm of gravel in the superior portion, immediately above the sand layer. The sand was the same, for both FA1 and FA2. The sand filters were fed by down stream. FA1 received effluents of equalization tank during 2 minutes and 45 seconds marked by stop watch, that and corresponds of a flow of 100 L of effluents. FA2 received effluents of the equalization tank during 5 minutes and 30 seconds, corresponding to 200 L of effluents. The average flow a minute was 22.84 l/m. it was verified low removal of organic natter through of total and filtered DQO, in the intermitted aerobic sand filters, with removal efficient bellow the minimum probable by NBR 13969/97 that is 40% may be associated to a short period of time of hydraulic detention in the septic tank due to the lack of periodic cleaning in the septic tank, passing to work like a single passage box. There were great efficiencies in the removal of nutrients, showing a good capacity of nitrification revealed in the nitrate concentration (28 mg/l and 29 mg/l) in FA1 and FA2 respectively and the different rates of application in the two intermitted aerobic sand filters influenced in the process of nitrification. / O lançamento de efluentes in natura nos solos ou nos recursos hídricos, seja de forma direta ou indireta, resulta, além de vários problemas socioambientais, em impactos significativos sobre a vida terrestre e aquática. A ausência de tratamento dos esgotos e sua destinação incorreta contribuem para agravar os problemas ambientais e particularmente de saúde pública. Este estudo tem como objetivo geral avaliar a aplicação de filtros aeróbios intermitentes de areia, como sistema alternativo de pós-tratamento de efluentes de filtro anaeróbio precedido de tanque séptico, visando à remoção de nutrientes e matéria orgânica de esgotos provenientes do Centro de Ciências e Tecnologia (CCT) da Universidade Estadual da Paraíba (UEPB). O sistema de pós-tratamento construído nesse estudo é formado por filtros aeróbios intermitentes de areia composto de caixas de fibra em polietileno (uma que atua como tanque de equalização e as outras duas como filtros aeróbios). Os dois filtros aeróbios de areia (FA 1 e FA 2) foram preenchidos com brita e areia na seguinte proporção: 15 cm de brita n⁰ 3 na base; 30 cm de areia na porção mediana, logo acima da camada de britas da base; 15 cm de brita na porção superior, logo acima da camada de areia. A areia utilizada foi a mesma, tanto para o FA 1 como para o FA 2.Os filtros de areia foram alimentados por meio de fluxo descendente. O FA1 recebeu efluente do tanque de equalização por 2 minutos e 45 segundos, marcado por cronômetro, o que corresponde a uma vazão de 100 L/dia de efluente. Já o FA2 recebeu efluente do tanque de equalização por 5 minutos e 30 segundos, correspondendo a 200 L/dia de efluente. A vazão média do sistema anaeróbio por minuto foi de 22.84 L/min. Verificou-se baixa remoção de matéria orgânica medida através da DQO total e filtrada, nos filtros aeróbios intermitentes de areia, com eficiências de remoção abaixo do mínimo previsto pela NBR 13969/97 que é de 40%, podendo estar associada ao curto tempo de detenção hidráulica no tanque séptico decorrente da falta de limpeza periódica no tanque séptico, passando a funcionar como uma simples caixa de passagem. Houve ótimas eficiências na remoção de sólidos suspensos no efluente dos filtros aeróbios. Os filtros de areia foram eficientes na transformação dos nutrientes, mostrando boa capacidade de nitrificação, revelada nas concentrações de nitratos (28,31 mg/L e 19,41 mg/L) em FA1 e FA2 respectivamente e as diferentes taxas de aplicação nos dois filtros aeróbios intermitentes de areia influenciaram no processo de nitrificação.
297

O impacto de uma lagoa receptora de efluentes industriais contendo boro em um aqüífero raso / Groundwater impact caused by an industrial effluente lagoon with boron

Tatiana Luiz dos Santos Tavares 18 September 2006 (has links)
O boro ocorre normalmente em baixas concentrações nas águas naturais destinadas ao abastecimento humano e agrícola, variando amplamente nas águas superficiais e subterrâneas. Embora apresente importância à saúde e ao ambiente, estudos detalhados sobre suas concentrações e seu comportamento em aquíferos ainda são restritos no Brasil. Este trabalho tem como objetivos, estudar e avaliar o impacto causado por uma lagoa receptora de efluentes industriais tratados no Aquífero Taubaté, em uma planta automotiva localizada no Município de Taubaté (SP). O estudo abrange um aquífero raso do tipo livre, heterogêneo, com valores de condutividade hidráulica variando de 1,08x10-5m/s a 1,7x10-7m/s. A recarga ocorre em toda a área fabril não impermeabilizada, bem como pela lagoa, sendo as zonas de descarga locais compostas por dois córregos. Os mapas potenciométricos referentes às campanhas de amostragem de julho de 2004 e março e outubro de 2005 apresentam fluxo radial da água subterrânea do lago para o aquífero e deste para as zonas de descarga locais. Os métodos utilizados consistiram na caracterização química e físico-química das águas de 26 poços de monitoramento instalados no entorno do lago, bem como da água superficial do lago, do solo do aquífero, do sedimento de fundo da lagoa e do solo subjacente aos sedimentos, todos amostrados em março e outubro de 2005. As análises dos parâmetros químicos e físico-químicos das águas subterrâneas e superficiais indicaram contaminação da água subterrânea ocasionada pela lagoa receptora de efluentes, com concentrações de boro superiores àquelas permitidas por lei (0,5mg/L). A pluma caracterizada tem maior comprimento de 120m e profundidade de até 10m. O monitoramento ao longo de um ano hidrológico permitiu identificar três ambientes hidroquímicos distintos no aquífero: bicarbonatadas sódicas, cloretadas sódicas e mistas sódicas, com teores variáveis de sulfato. A presença de altas concentrações de sódio, cloreto e sulfato são decorrentes dos lançamentos de efluente na lagoa e à influência desta em relação ao aquífero. Verificou-se que os sedimentos de fundo do lago formam uma barreira hidroquímica retendo as maiores concentrações de boro (211,6 - 257,6mg/L), tornando-se consequentemente uma fonte secundária desse elemento, cujo comportamento está diretamente relacionado com o pH da água do lago. O sistema lago/aquífero quanto ao boro encontra-se em equilíbrio após dois anos e meio do cessar da fonte primária, constituída por óleos solúveis contendo boro, porém, a pluma de boro ainda encontra-se em movimento no sentido do fluxo. / The boron (B) occurs naturally at low concentrations in surface and ground waters used to human supply and irrigation. Although concentration >1mg/L can cause health and environmental problems, detailed studies on transport and fate of B in aquifers are restricted in Brazil. This study investigated the impacts on groundwater quality caused by an industrial (automobile plant) effluent lagoon into a shallow, unconfined sandy clay aquifer (Taubaté Aquifer) in Taubaté (São Paulo, Brazil). This aquifer is heterogeneous with a hydraulic conductivity varying from 1,08x10-5m/s to 1,7x10-7m/s. The recharge occurs in the whole area (except where the surface is impermeable), and associated to the lagoon. The potentiometric maps indicate radial direction flow from the lagoon to the aquifer and then toward the two streams located in the east and west sides of industrial plant. The present study is based on chemical analyses of groundwater (26 shallow monitoring wells - 3 to 15m deep), surface water (effluent lagoon), and soil and sediments from the bottom of the lagoon, aquifer and surface surround the lagoon in different period of the year. Analyses performed for major elements, B, pH, Eh, and electric conductivity showed the existence of a B plume surrounding the lagoon with maximum length of 120m and deep of 10m. The three different hydrochemical environments were identified: sodium bicarbonate, sodium chloride and sodium mixed waters, with variable concentrations of sulfate. The sediment of the bottom of the lagoon acts as a hydrochemical barrier adsorbing the B. This sediment is a secondary source of this contaminant. The adsorption mechanism is controlled by the pH of lagoon water. The lagoon/aquifer system is in relative equilibrium after 2 ½ years since the interruption of the release of B into the lagoon, however, the plume in low concentration is still moving through the aquifer.
298

Uniformidade de irrigação por gotejamento usando efluente tratado de abatedouro de aves / Uniformity in drip irrigation for treated wastewater application from poultry slaughterhouse

Morais, James 07 July 2018 (has links)
Submitted by Neusa Fagundes (neusa.fagundes@unioeste.br) on 2018-02-05T18:26:08Z No. of bitstreams: 2 James_ Morais2018.pdf: 2489413 bytes, checksum: 8a6f574d868e585f5e6e2fef836e47fb (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-02-05T18:26:08Z (GMT). No. of bitstreams: 2 James_ Morais2018.pdf: 2489413 bytes, checksum: 8a6f574d868e585f5e6e2fef836e47fb (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-07-07 / The processes that take part of poultry slaughter are responsible for a great amount of water consumption and, consequently, a generation of large volumes of wastewater, which are usually disposed on soil without any control of uniformity regarding its distribution. Thus, this study aimed at evaluating a drip irrigation system, applied to dispose treated poultry slaughterhouse effluent on soil, using three effluent application rates of 100, 200 and 300 m³ ha-1 day-1. Besides the irrigation system, the effluent quality was also evaluated according to its physical-chemical characteristics. The evaluation of the results was given by the following coefficients: Christiansen Uniformity (CUC), Uniform Distribution (UDC), the Statistical Uniformity Coefficient (SUC) as well as quality control techniques. This trial was carried out in an eucalyptus reforestation area from the Industrial Poultry Slaughterhouse of Lar Agroindustrial Cooperative, in Matelândia city, PR. According to data obtained in this research, it was concluded that drip irrigation system, using the proposed rates, can be considered adequate, since it has shown uniformity in distribution of flows, pH and electrical conductivity. For pH and electrical conductivity, all the evaluated uniformity coefficients, CUC, UDC and SUC, were estimated in more than 90% and considered excellent. For the flow rates, all the coefficients were estimated as superior to 90% for 100 m³ ha-1 day-1 treatment and above 80% for treatments of 200 and 300 m³ ha-1 day-1. Usually, the distributions showed the highest coefficient of uniformity for the three parameters evaluated in the three studied treatments, for the highest tested rate of application. Regarding the effluent characterization, it was concluded that its main characteristics are the concentrations of nitrogen, phosphorus and carbon. And during the experiment, the industry kept the standards of disposal in the environment, which were determined by the environmental agencies. Finally, it was concluded that the statistical process control is adequate to evaluate the effluents as well as irrigation uniformity in tests area. / Os processos inerentes ao abate de aves respondem por um grande consumo de água e, consequentemente, a geração de grandes volumes de efluentes que, em geral, são dispostos no solo sem qualquer controle de uniformidade sobre a distribuição. Assim, o objetivo deste estudo foi avaliar um sistema de irrigação por gotejamento, aplicado à disposição de efluente tratado de abatedouro de aves no solo, utilizando três taxas de aplicação de efluente: 100, 200 e 300 m³ ha-1 dia-1. Além do sistema de irrigação, a qualidade do efluente também foi avaliada em função das características físico-químicas. A avaliação dos resultados foi dada pelos Coeficientes de Uniformidade de Christiansen (CUC), de Uniformidade de Distribuição (CUD), de Uniformidade Estatístico (CUE), bem como pelas técnicas de controle de qualidade. O experimento foi realizado na área de reflorestamento com eucalipto da Unidade Industrial de Aves da Lar Cooperativa Agroindustrial, em Matelândia, PR. De acordo com os dados obtidos neste trabalho, concluiu-se que o sistema de irrigação por gotejamento, utilizando-se as taxas propostas, pode ser considerado apropriado, pois apresentou uniformidade na distribuição das vazões, do pH e da condutividade elétrica. Para o pH e a condutividade elétrica, todos os coeficientes de uniformidade avaliados, CUC, CUD e CUE, foram estimados em mais de 90%, considerados excelentes. Para as vazões, todos os coeficientes foram estimados acima dos 90% para o tratamento de 100 m³ ha-1 dia-1 e acima dos 80% para os tratamentos de 200 e 300 m³ ha-1 dia-1. Em geral, as distribuições apresentaram maior coeficiente de uniformidade, para os três parâmetros avaliados, nos três tratamentos, para a maior taxa de aplicação testada. Em relação à caracterização do efluente, concluiu-se que suas principais características são as concentrações de nitrogênio, fósforo e carbono. E, durante o experimento, a indústria manteve os padrões de lançamento no ambiente, determinados pelos órgãos ambientais. Por fim, concluiu-se que o controle estatístico de processo é adequado à avaliação, tanto de efluentes quanto de uniformidade na irrigação, em testes a campo.
299

Avaliação da nitrificação de efluente de abatedouro de tilápia em reator em batelada seqüencial aerado com biomassa imobilizada / Evaluation of the nitrification of the tilapia slugtherhouse effluent in the sequential batch reactor with immobilized biomass

Zenatti, Dilcemara Cristina 25 January 2007 (has links)
Made available in DSpace on 2017-07-10T19:23:42Z (GMT). No. of bitstreams: 1 Dilcemara Cristina Zenatti.pdf: 3283328 bytes, checksum: 7aa4b120d287db79b605fc5010d7c5e6 (MD5) Previous issue date: 2007-01-25 / Universidade Federal do Paraná. Campus de Palotina / The agribusiness possesses a high potential of negative environmental impacts related to the generation of residues, overcoat of liquid effluents rich in organic matter and nutrients. The release of those no treated effluents has been the cause of serious damages to the environment. The biological treatment of the nitrogen compositions has been an alternative to improve the quality of the effluents. One of the biological processes is constituted of the nitrification follow by desnitrification, being the nitrification the limiting factor for good performance of the system. The objective of this work was to evaluate the influence of the aeration and of the time of reaction in the process of nitrification of the tilapia effluent in sequential batch reactor with immobilized biomass. The experiment was driven in laboratory scale where two levels of flow of air were tested (QAr = 3 and 6 L.min-1) and two levels of time of reaction (TR = 6 and 12 hours), configuring a factorial experimental planned with four treatments: T1 (QAr=3 L.min-1 and TR = 6:00); T2 (QAr=6 L.min-1 and TR = 6:00), T3 (QAr=3 L.min- 1 and TR = 12:00) and T1 (QAr=6 L.min-1 and TR = 12:00), and four repetitions. The efficiency of Conversion was evaluated (%) of the amoniacal nitrogen to nitrate, the efficiency of Removal (%) of amoniacal nitrogen and the kinetic profile of the nitrification, with the calculation of the apparent kinetic constants k1 and k2. The results showed that the increase in the reaction time (TR) and the increment in the air flow is favorable in the nitrification process. Being that the T4 treatment was what presented better resulted in all the factors analyzed with average values of efficiency for conversion and removal of 57,27± 27,05% and 81,90±3,80, respectively and 0,00300±0,00030 min-1 and 0,00298±0,00024 min-1 for the apparent constants k1 and k2. / A agroindústria possui um elevado potencial de impactos ambientais negativos relacionados à geração de resíduos, sobretudo de efluentes líquidos ricos em matéria orgânica e nutrientes. O tratamento biológico dos compostos nitrogenados tem sido uma alternativa para melhorar a qualidade dos efluentes. Um dos processos biológicos constitui-se da nitrificação seguida da desnitrificação, sendo a nitrificação fator limitante para o bom desempenho do sistema. O objetivo deste trabalho foi avaliar a influência da aeração e do tempo de reação no processo de nitrificação de efluente de abatedouro de tilápia em reator em batelada seqüencial com biomassa imobilizada. O experimento foi conduzido em escala de laboratório onde foram testados dois níveis de vazão de ar (QAr = 3 e 6 L.min-1) e dois níveis de tempo de reação (TR = 6 e 12 horas), configurando um planejamento experimental fatorial com quatro tratamentos: T1 (QAr=3 L.min-1 e TR= 6h); T2 (QAr=6 L.min-1 e TR= 6h), T3 (QAr=3 L.min-1 e TR= 12h) e T1 (QAr=6 L.min-1 e TR= 12h), e quatro repetições para cada tratamento. Avaliou-se a eficiência de Conversão(%) do nitrogênio amoniacal a nitrato, a eficiência de Remoção(%) de nitrogênio amoniacal e o perfil cinético da nitrificação, com o cálculo das constantes cinéticas aparentes k1 e k2. Os resultados mostraram que o aumento no tempo de reação (TR) e o incremento na vazão de ar foram favoráveis no processo de nitrificação, sendo que o tratamento T4 foi o que apresentou melhores resultados em todos os fatores analisados com valores médios de eficiência para conversão e remoção de 57,27 ± 27,05% e 81,90 ± 3,80, respectivamente e 0,00300 ± 0,00030 min-1 e 0,00298 ± 0,00024 min-1 para as constantes aparentes k1 e k2.
300

Produção de hidrogênio e metano em reatores anaeróbios de leito fixo em série a partir de efluente de fecularia de mandioca / Hydrogen and methane production in anaerobic reactors of fixed bed in serie from cassava starch wastewater

Lucas, Shaiane Dal' Maso 20 February 2015 (has links)
Made available in DSpace on 2017-07-10T19:24:02Z (GMT). No. of bitstreams: 1 Shaiane__Lucas.pdf: 2393290 bytes, checksum: 9e5c684ef130e9552f01b3191e3e8e1d (MD5) Previous issue date: 2015-02-20 / This study evaluated the hydrogen and methane production from cassava starch wastewater in reactors in series. The acidogenic and methanogenic reactors were operated in a continuous flow and trials were divided into three stages. In Stage 1, three essays for hydrogen production evaluated the effect of initial pH (6.0 and 4.5), substrate concentration (1.4, 1.1 and 2.2 g total carbohydrates.L-1) and strategies to control biomass (by disposal or change in the structure of such support material with low density polyethylene) in anaerobic reactors of fixed bed and upflow at 36 °C. The best operating condition among the evaluated ones was pH 6.0 and concentration of 1.4 g total carbohydrates.L-1, which resulted in Hydrogen Volumetric Productions (HVP) of 229 mL.L-1.d-1 and yield of 29.4 mL.g-1total carbohydrate. The best strategy to control biomass was the sort of bed with polyethylene cylinders, which provided the least changes in flow regime and excessive growth of biomass. In Stage 2, the effect of inoculum source was evaluated in two packed-bed reactors operating according to the following conditions: pH 6.0; 2 g.L-1concentration of substrate, 20 g.L-1.d-1organic loading rate (OLR) and hydraulic retention time (HRT) of 2-hour. In the inoculated reactor with autofermented effluent, the answers were: 550 mL.L-1.d-1and hydrogen yield of 38mL.g-1total carbohydrates. These values were higher than those observed for the reactor inoculated with anaerobic heat-treated sludge, which indicated that the use of simple inoculums is a viable strategy for hydrogen production under the tested conditions. In addition to these essays, the influence of ORL and HRT were also evaluated. The increase of ORL (10 to 20 g-total carbohydrates.L-1.d-1) and decrease of HRT (4 to 2 hour) resulted in a higherhydrogen production (467 mL.L-1.d-1), hydrogen percentage in the studied biogas (40%) and molar flow rate (2.16 mmol.h-1). Therefore, the average yield of 30 mL H2.g-1 total carbohydrate was the same for both conditions tested. In general, butyric acid was associated with higherhydrogen production, followed by acetic and propionic acids, besides ethanol, in the five analyzed essays. In Stage 3, methane production from the acidified effluent was evaluated in a horizontal anaerobic reactor of fixed bed and continuous flow, operated at mesophilic temperature. The operating conditions were divided into four stages, whose variations were: initial pH (5.0 and 7.0), OLR (1.54; 3.54 and 6 g-COD.L-1.d-1) and HRT (5; 1.5 and 1.1 d). The results of effluent pH greater than 7.0, volatile acidity/total alkalinity of 0.2 and 98% removal of organic matter showed that the reactor performance was not impaired by the separation of acidogenic and methanogenic stages. The highest production of methane was observed in Phase IV, with pH 5.0, 6 g.L-1.d-1 OLR and 1.1 d HRT, resulting in average values of 0.82 L.L-1.d-1 for volumetric methane production, 0.85 L.g-1CODremoved yield and 80% methane in biogas composition. The energy efficiency in the combined system was 17% higher than the one observed in the single system for the treatment of cassava starch wastewater. / Este trabalho avaliou a produção de hidrogênio e metano a partir de efluente de fecularia de mandioca em sistema combinado. Os reatores acidogênico e metanogênico foram operados em fluxo contínuo, e os ensaios divididos em três etapas. Na Etapa 1, três ensaios para produção de hidrogênio avaliaram o efeito do pH inicial (6,0 e 4,5), concentração de substrato (1,4, 1,1 e 2,2 g carboidratos totais.L-1) e estratégias de controle da biomassa (por descarte ou mudança na estruturação do material suporte de polietileno de baixa densidade) em reatores anaeróbios de leito fixo e fluxo ascendente, à temperatura de 36 C. A melhor condição operacional dentre as avaliadas foi pH 6,0 e concentração de 1,4 g carboidratos totais.L-1, que resultou em Produções Volumétricas de Hidrogênio (PVH) de 229 mL.L-1.d-1 e rendimento de 29,4 mL.g-1 carboidrato total. A melhor estratégia de controle de biomassa foi a ordenação do leito com cilindros de polietileno, a qual proporcionou menores alterações no regime de escoamento e crescimento excessivo da biomassa. Na Etapa 2, o efeito da fonte de inóculo foi avaliado em dois reatores de leito empacotado nas condições operacionais pH 6,0; concentração de substrato de 2 g.L-1, Carga Orgânica Volumétrica aplicada (COV) de 20 g.L-1.d-1 e Tempo de Detenção Hidráulica (TDH) de 2 horas. No reator inoculado com efluente autofermentado verificou-se PVH de 550 mL.L-1.d-1 e rendimento de hidrogênio de 38 mL.g-1 carboidratos totais. Esses valores foram maiores que os observados para o reator inoculado com lodo anaeróbio tratado termicamente, os quais indicaram que a utilização de inóculos simples representa uma estratégia viável para produção de hidrogênio nas condições testadas. Além desses ensaios, a influência da COV e do TDH também foi avaliada. O aumento COV (de 10 para 20 g.L-1.d-1) e a redução do TDH (de 4 para 2 h) resultaram em maior produção de hidrogênio (467 mL.L-1.d-1), percentual de hidrogênio no biogás (40%) e vazão molar (2,16 mmol.h-1). Entretanto, o rendimento médio de 30 mL H2.g-1 carboidrato total foi igual para as duas condições testadas. De modo geral, o ácido butírico foi associado à maior produção de gás hidrogênio, seguido dos ácidos acético e propiônico, além de etanol, nos cinco ensaios realizados. Na Etapa 3, a produção de metano a partir do efluente acidificado foi avaliada em reator anaeróbio horizontal de leito fixo e fluxo contínuo, operado em condição mesofílica de temperatura. As condições operacionais foram divididas em quatro fases, com variação do pH inicial (5,0 e 7,0), da COV (1,54; 3,54 e 6 g DQO.L-1.d-1) e do TDH (5; 1,5 e 1,1 d). Os resultados de pH efluente superior a 7,0, relação acidez volátil/alcalinidade total de 0,2 e remoção de 98% da matéria orgânica evidenciam que o desempenho do reator não foi prejudicado pela separação das fases acidogênica e metanogênica. A maior produção de metano foi observada na Fase IV, com pH 5,0, COV de 6 g.L-1.d-1e TDH de 1,1 d, que resultou em valores médios de produção volumétrica de metano de 0,82 L.L-1.d-1, rendimento de 0,85 L.g-1DQOremovida e 80% de metano na composição do biogás. O rendimento energético no sistema combinado foi 17% superior ao observado em sistema único no tratamento de efluente de fecularia.

Page generated in 0.3362 seconds