• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 983
  • 10
  • 7
  • 7
  • 1
  • Tagged with
  • 1015
  • 646
  • 219
  • 217
  • 186
  • 168
  • 163
  • 135
  • 127
  • 118
  • 118
  • 104
  • 100
  • 83
  • 77
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
311

Avaliação respirométrica de reatores biológicos associados à membranas no tratamento de efluentes hospitalares sob condições de choque de fármacos

Della Giustina, Saulo Varela January 2014 (has links)
A presença de fármacos em geral em corpos hídricos superficiais e em águas subterrâneas tem chamado a atenção para os riscos potenciais para a saúde do homem e do ambiente, já que estes compostos são facilmente encontrados em águas residuárias oriundas de hospitais e efluentes domésticos. As tecnologias convencionais de tratamento, tanto por via aeróbia como por via anaeróbia não promovem remoções significativas de produtos farmacêuticos. Reatores Biológicos Associados a Membranas (MBRs) tem obtido significante aceitação como uma tecnologia avançada de tratamento de águas residuárias, podendo ser efetivo na remoção destes micropoluentes orgânicos. No entanto, informações referentes ao desempenho dos MBRs referentes à remoção de micro-poluentes ainda é escassa. A partir da problemática levantada e da relevância do sistema, a presente pesquisa teve como objetivo principal a avaliação do desempenho de MBRs sob condições de choque de fármacos, através do monitoramento respirométrico do lodo baseado na Taxa de Consumo de Oxigênio (TCO), bem como a presença de Substâncias Poliméricas Extracelulares (EPS), Resistência à Filtração, nitrificação e desnitrificação, a fim de avaliar o processo diante de condições críticas de operação. Os choques foram realizados nas concentrações de 0,5; 1,0 e 2,0 mg.L-1 para os fármacos Paracetamol, Tetraciclina, Metformina e Enalapril, sendo dosados de duas formas: (1) na forma de pulso de concentração; (2) dosagem contínua na alimentação do sistema. A dosagem na forma de pulso ocasionou maiores efeitos sobre a desnitrificação do sistema, com destaque para as concentrações de 2,0mg.L-1 para Paracetamol e Tetraciclina. Os efeitos, no entanto, foram temporários. A remoção de DQO não foi afetada para nenhum fármaco e dosagem testada, ou mesmo a forma de dosagem. A forma de dosagem em pulso resultou em interferências mais perceptíveis na TCO, Resistência à filtração e EPS, apesar de que esta interferência não ocorreu simultaneamente para todos os parâmetros de monitoramento ou não foi detectado por algum destes, o que reforça a necessidade de um monitoramento conjunto. O EPS mostrou resultados estáveis para o monitoramento de eventos curtos, tais como os choques na forma de pulso. / The presence of pharmaceuticals in surface water bodies and groundwater has drawn attention to the potential risks to human health and the environment, as these compounds are easily found in wastewaters originated from hospitals and domestic effluents. Conventional wastewater treatment technologies, both aerobically and anaerobically do not promote significant removal of pharmaceuticals. Membrane Bio Reactors (MBRs) have obtained significant acceptance as an advanced technology for wastewater treatment and may be effective in removing this organic micropollutants. However, information regarding the performance of MBRs referring to the removal of micropollutants is still scarce. From the issues raised this study aimed to e evaluate the performance of MBR under shock loads conditions applying respirometric monitoring of sludge through the Oxygen Uptake Rate (OUR), Extracelular Polimeric Substances (EPS), Filtration Resistance, nitrification and denitrification in order to evaluate the process under critical operating conditions. The shocks were performed at concentrations of 0.5, 1.0 and 2.0 mg.L -1 for paracetamol, tetracycline, Metformin and Enalapril drugs being measured in two ways: (1) in the form of a slug dosage; (2) the continuous dosing with the raw wastewater. The slug dosage strategy caused greater effects on denitrification system, though few effects were observed upon nitrification, especially for concentrations of 2.0mg.L-1 for Paracetamol and Tetracycline. Nevertheless the effects were temporary. The COD removal was not affected by any drug and dosage tested, or even the dosage form. The dosage form pulse resulted in more noticeable interference in OUR, Resistance filtration and EPS, although this interference did not occur simultaneously for all monitored parameters or was not detected for some of these, which reinforces the need for a more detailed monitoring set. EPS presented stable results for monitoring short events such as the slug dosage shock loads.
312

Aproveitamento de subprodutos do beneficiamento de carvão mineral na remoção de poluentes por sorção-flotação FAD

Feris, Liliana Amaral January 2001 (has links)
O presente trabalho analisou a sorção (absorção e adsorção) de íons metálicos (principalmente Cu, Zn, Ni) e poluentes orgânicos por subprodutos do beneficiamento do carvão (SBC) do Rio Grande do Sul e sua separação da solução por flotação por ar dissolvido (FAD). Esse conjunto de técnicas, denominado flotação de partículas sorventes (FPS), foi estudado em escala de bancada e piloto como alternativa para a remoção-separação desses metais pesados dissolvidos em soluções sintéticas diluídas e efluentes industriais. O sólido sorvente utilizado foi devidamente selecionado entre os diversos produtos existentes (rejeitos de jigagem de várias camadas) e caracterizado desde o ponto de vista químico, morfológico, mineralógico, petrográfico e interfacial (sólido/líquido). A sorção foi estudada em função do pH do meio, granulometria, curvas de acumulação e parâmetros cinéticos. O mecanismo de sorção dos íons metálicos foi estudado em detalhe através de isotermas de sorção, microscopia eletrônica de varredura, força atômica e potencial zeta. A complexação interfacial entre as espécies hidrolisadas Me(OH)+ e a superfície negativamente carregada dos silicatos (principalmente caulinita) e vitrinita mostrou ser o principal mecanismo envolvido. A sorção dos íons Cu, Zn e Ni em função do pH e da formação das espécies hidrolisadas ocorre em valores de pH superiores a 5 para Cu e Zn e acima de pH 9 para Ni. Em relação à cinética de sorção, tempos de contato em torno de 7 min foram suficientes para alcançar uma elevada eficiência de remoção de íons metálicos. Isotermas de sorção apresentaram valores de saturação da ordem de 70 mg.g-1 para soluções contendo Cu, Zn e Ni simultaneamente e pH 9,5; 16 mg.g-1 para soluções contendo somente Cr-+3; 650 mg.g-1 para óleos e 46 mg.g-1 para corantes (azul de metileno). Estudos microscópicos permitiram caracterizar a estruturas das diferentes espécies que compõem o sólido e as variações na superfície do SBC antes e após sorção. Foram realizados estudos de otimização do sistema FAD considerando fatores físicoquímicos e operacionais. Foi descoberta uma forma de geração de microbolhas em baixas pressões de saturação (< 3 atm.) pela redução da tensão superficial da água no saturador. A redução da tensão superficial do líquido diminui a fricção no constritor de fluxo permitindo a cavitação a baixas pressões. Essa técnica diminui o consumo energético do processo de saturação, um dos maiores custos operacionais da FAD. A zona de separação da célula de flotação foi modificada introduzindo um segundo difusor de ar tipo “cogumelo”. Esse artifício possibilitou a captura de agregados de partículas que normalmente sedimentam em função do peso ou de unidades bolha-partícula que se rompem. O processo FPS-FAD (piloto) foi aplicado à remoção de íons Cu, Zn, Ni e Cr+3 em soluções sintéticas diluídas e efluentes de galvanoplastia. Valores superiores a 90% foram obtidos com soluções sintéticas. Por outro lado, o nível de remoção observado nos ensaios de sorção em efluentes sintéticos não foi atingido na operação do sistema com efluente industrial. Nesse caso, a presença de metais complexos, óleos e colóides diminuiu a eficiência do processo FPS-FAD. Conclui-se que a alternativa tecnológica estudada demonstrou eficiência no tratamento de efluentes líquidos contendo baixas concentrações de poluentes (melhor, na ausência de complexos e quelatos). A alta área superficial do SBC ICA, capacidade de sorção de poluentes (metais pesados, óleos e corantes), o baixo custo envolvido (basicamente moagem e transporte) sua abundância (6000 t/mês) conferem ao sólido um grande potencial de aplicação e vantagens econômicas. Por último, as modificações no “design” da unidade FAD deverão produzir significativos benefícios operacionais e no custo global do processo pré-avaliado em 0,69 US$/m3 para uma unidade com geração diária de 100 m3 de efluente. / The present work studied the removal of heavy metal ions (mainly Cu, Zn and Ni) organic compounds by sorption (absorption and adsorption) onto a coal beneficiation tailing from the coal industry of Rio Grande do Sul and its separation by dissolved air flotation (DAF). This technique, named adsorptive particulate flotation (APF), was studied in laboratorial and pilot scale as an alternative for pollutants removal and separation from synthetic solutions and industrial wastewaters. The sorbent material used in this work was selected from different byproducts (jigging refuses) and its morphological, mineralogical, chemical, physical and interfacial (solid/liquid) characteristics were studied in detail. Sorption studies were carried out as function of pH, particle size, isotherm curves and kinetics. Mechanisms involved in sorption were investigated through sorption isotherms, zeta potential, scanning electron and atomic force microscopy. The most important sorption mechanism is considered to be the interfacial complexation between the hydrolyzed species Me(OH)+ and the negatively charged silicates and vitrinite surfaces. The sorption of Cu, Zn and Ni as a function of pH and hydrolyzed species formation was found to occur at pH values higher than 5 for Cu and Zn, while Ni sorption was found to occur at pH values higher than 9. Concerning kinetics, residence time of 7 min allowed the process to achieve high ions removal efficiency. Sorption isotherms showed saturation values of the order of 70 mg.g-1for heavy metal ions (Cu, Zn and Ni at pH=9.5), 16 mg.g-1 Cr-3, 650 mg.g-1 for oils and 46 mg.g-1 for dyes (methylene blue). Microscopic techniques were used to study the different SBC ICA compounds mineralogical structures and the surface variations before and after sorption. The dissolved air flotation process was improved considering physical, chemical and operational parameters. The bubble generation system was optimized using an innovative procedure of decreasing the liquid interfacial tension in the saturation vessel. This technique allows the DAF system to operate with low saturation pressures (<3atm), which decreases de energy operational costs. Further, studies were conducted changing the flotation cell design. A “mushroom” type diffuser was installed in the separation zone and better performance was obtained. This modification enhances the collection of fragile coagula by bubbles, avoiding aggregate rupture and settling. The APF process was applied for the removal of Cu, Zn, Ni and Cr+3 ions from synthetic and industrial wastewaters. In general, the removal efficiency achieved in batch sorption experiments with synthetic solutions was also found in the pilot operation with industrial effluents. However, it was observed that heavy metal complexes and oils interfere in the sorption. It is concluded that the process alternative studied in this work demonstrated high efficiency for the removal of low concentration pollutants in wastewaters treatment. Because of the high SBC ICA surface area, the pollutants affinity and high sorption values (heavy metal ions, oils and dyes) and the solid availability (6000 t/month), these tailings present high potential as sorbing material at a low cost. Finally, the modifications in the DAF cell design lead the process to operational advantages and cost reduction. The global cost was pre-evaluated in 0.69 US$/m3 for a wastewater plant with an effluent generation of 100 m3/day.
313

Efeito da exposição ao efluente de curtume em diferentes modelos animais

Moysés, Felipe dos Santos January 2014 (has links)
Atualmente, o aumento da produção industrial, assim como várias ações humanas, resultam no lançamento de substâncias químicas no meio ambiente. Entre os diversos poluentes, o efluente proveniente da indústria do couro é considerado um dos maiores contaminantes dos recursos hídricos. Neste contexto, o estresse oxidativo é sugerido como um dos mecanismos bioquímicos da toxicidade de vários contaminantes ambientais, e alterações nas atividades de enzimas responsáveis pela detoxificação de xenobióticos podem ser utilizadas no monitoramento dos efeitos nocivos destas substâncias. Assim, este trabalho teve como objetivo central avaliar o efeito da exposição ao efluente de curtume sobre parâmetros oxidativos, principalmente por meio da avaliação das atividades de enzimas antioxidantes em diferentes modelos animais, roedores e insetos. Na primeira etapa, avaliou-se os efeitos da exposição in vitro ao efluente de curtume sobre o estado oxidativo e as atividades da superóxido dismutase, glutationa peroxidase e glutationa S-transferase em estruturas cerebrais (córtex, estriado e hipocampo) e fígado de ratos e camundongos. No fígado, observou-se que a exposição ao efluente de curtume induziu um aumento nas atividades das glutationa peroxidase e glutationa S-transferase nos ratos, enquanto que, em camundongos não houve alterações nas atividades destas enzimas. Em relação à formação das espécies reativas, observou-se um aumento no fígado dos camundongos, e o mesmo não foi detectado em ratos. Este resultado pode estar relacionado com o aumento nas atividades da glutationa peroxidase e glutationa S-transferase, já que estas enzimas são relacionadas com detoxificação de xenobióticos. Nas estruturas cerebrais, a exposição ao efluente de curtume induziu efeitos similares em ratos e camundongos, uma vez que houve um aumento nos níveis de espécies reativas no cerebelo, hipocampo e córtex, assim como um perfil semelhante na atividade das enzimas avaliadas nestas estruturas. Estes resultados sugerem que camundongos são mais suscetíveis já que a exposição não ocasionou um aumento nas atividades das enzimas do sistema glutationa no fígado, indicando que a biodisponibilidade central dos compostos presentes no efluente de curtume pode ser maior em camundongos. Na segunda etapa, avaliou-se os efeitos da exposição de Drosophila melanogaster adultas por 72 horas ao efluente de curtume. Após a exposição, foi quantificada a mortalidade e as atividades da superóxido dismutase, glutationa peroxidase e glutationa S-transferase. Neste estudo, observou-se um aumento da letalidade. Foi detectado também, um aumento na atividade da glutationa peroxidase. No entanto, observou-se decréscimo na atividade de glutationa S-transferase nas moscas expostas ao contaminante. Considerando estes resultados, é possível sugerir que a exposição ao efluente proveniente do curtume pode alterar o sistema antioxidante enzimático, e que Drosophila melanogaster parece ser um bom modelo para avaliar a toxicidade induzida pelo efluente de curtume. Os resultados desta Tese apoiam a ideia de que alterações no sistema antioxidante enzimático podem estar relacionadas com efeitos tóxicos da exposição ao efluente de curtume, e que, em parte, estas alterações podem elucidar o mecanismo pelo qual o contaminante causa resposta divergente em roedores, além de que os compostos deste efluente podem impactar na sobrevivência e no sistema antioxidante de insetos adultos. / Actually, chemicals have been widely released to the environment. Among the many pollutants emitted into the environment, the effluent from the leather industry is considered one of the greatest contamination of water resources. In this context, the oxidative stress has been suggested as a central biochemical mechanism of toxicity from several environmental toxicants, and changes in the enzymes activities responsible for the detoxification of xenobiotics can be used in monitoring the harmful effects of these substances. Thus, this study aimed to evaluate the effect of exposure to tannery wastewater on oxidative parameters, and mainly studying the enzymatic activities in different animal models. In the first step of this study, it was evaluated the effects of in vitro exposure to tannery wastewater on oxidative status, and activities of superoxide dismutase, glutathione peroxidase and glutathione S-transferase in brain structures (cortex, striatum and hippocampus) and liver of the rats and mice. It was observed that exposure to tannery wastewater induced an increase in the activity of glutathione peroxidase and glutathione S-transferase in the rats liver, whereas no changes were detected in the hepatic enzymes in mice. Regarding the formation of reactive species, there was an increase in the mice liver, and it was not detected any effect in rat liver This result may be related to the increase in the activity of glutathione peroxidase and glutathione S-transferase since these enzymes have been related to detoxification of xenobiotics. Exposure to effluent induced similar effects in brain structures from rats and mice, since there was an increased in the free radical levels in the cerebellum, hippocampus and cortex, as well as a similar profile in the activity of the enzymes evaluated in these brain structures from both species. These results suggest that mice are more susceptible since the exposure did not cause an increase in the activity of the enzymes glutathione system in the liver, indicating that the central bioavailability of the compounds in tannery wastewater may be higher in mice. In the second section, it was evaluated the effects of exposure of adult Drosophila melanogaster placed for 72 hours with tannery effluent. After exposure, mortality was quantified, and it was evaluated the activities of superoxide dismutase, glutathione peroxidase and glutathione S-transferase. In this work, exposure to tannery effluent induced lethality in flies. We also detected an increase in glutathione peroxidase activity. However, there was a decrease in the glutathione S-transferase activity in flies exposed to contaminant. Considering these results, it is possible to suggest that exposure to tannery effluent can modify the enzymatic antioxidant system in insects, and Drosophila melanogaster is a reliable model to evaluate the toxicity induced by tannery wastewater. The results of this study support the idea that alterations in enzymatic antioxidant system may be associated with toxic effects of exposure to tannery wastewater and, in part, these changes can clarify the mechanism by which the contaminant causes a divergent response in rodents and insects.
314

Interações de íons sulfato com sais de alumínio em soluções ácidas. Estudos básicos e aplicações ambientais

Silva, Renato Dantas Rocha da January 2011 (has links)
O presente trabalho teve o objetivo de estudar os aspectos químicos básicos envolvidos nas interações (co-precipitação e adsorção) entre íons sulfato e espécies de alumínio em soluções aquosas em meio ácido e aplicar esta técnica de imobilização do ânion, no tratamento de efluentes da indústria do carvão. Os estudos foram desenvolvidos com o uso de cloreto de polialumínio comercial (CPA) e soluções de cloreto de alumínio (AlCl3.6H2O - reagente de pureza analítica) em diferentes valores de pH e sob diferentes razões molares entre os íons de alumínio e íons sulfato (α). Os mecanismos dessas interações físicas e químicas (adsorção e co-precipitação) foram investigados a partir da distribuição das espécies monoméricas, poliméricas e hidróxidos de alumínio em solução (especiação de Ala, Alb e Alc, respectivamente) realizada pelo método Ferron e da caracterização dos precipitados gerados por técnicas de espalhamento dinâmico de luz, difração a laser, microscopia eletrônica de varredura (MEV), energy dispersive X-ray (EDS), difração de raio-X e fluorescência de raio-X. Os resultados mostraram que elevados teores de espécies Alb e Alc foram gerados em soluções moderadamente ácidas, pH entre 4,5 e 5,0. Essas espécies apresentaram potencial eletrocinético, no plano zeta, fortemente positivo (superior a +35 mV), reduzido para +24 mV na presença de íons sulfato, e essa característica dos precipitados resultou em forte imobilização de íons sulfato em pH 4,5, superior a 85% quando a concentração inicial foi de 1800 mg de SO4-2.L-1. Essa interação mostrou-se de natureza química em função da alteração do ponto isoelétrico do precipitado de alumínio do pH 9,3 para o pH 8,5, ou seja, foi comprovado que o ânion foi incorporado no plano interno de Helmholtz, dos precipitados Al-Sulfato. Entretanto, o aumento do pH da solução resultou na lixiviação parcial do ânion do precipitado Al-Sulfato, fenômeno que se explica pelo mecanismo de adsorção física. Análises granulométricas mostraram que espécies de alumínio em água pura apresentaram distribuição de tamanho de até 50 μm, incluindo espécies Alb e Alc. Entretanto, as espécies mais finas, menores que 6 μm, foram agregadas na presença de íons sulfato, exclusivamente no pH 4,5, em função do mecanismo de co-precipitação desses ânions. Os sólidos gerados da co-precipitação dos íons sulfato com espécies de alumínio apresentaram característica amorfa e a formação desse precipitado resultou em incremento de até 30% na imobilização de espécies de alumínio. Outro importante aspecto na interação Al-Sulfato foi a basicidade (razão OH/Al) dos sais de alumínio devido ao grau de polimerização das espécies do cátion metálico. Os melhores resultados de imobilização de íons sulfato foram obtidos a uma basicidade igual a 2,2. Similarmente, o uso de CPA comercial, em função da presença de espécies de alumínio pré-polimerizadas, resultou em maior imobilização dos íons sulfato comparado ao uso de cloreto de alumínio. Entretanto, a concentração final dos íons cloreto em solução foi superior a 1000 mg.L-1, indicando a necessidade de estudar outras fontes de alumínio isentas de cloro em sua composição, substituindo o CPA e o cloreto de alumínio. Outros ânions como os fosfatos, molibdatos e cromatos apresentaram afinidade similar com espécies de alumínio em pH 4,5. A aplicação da técnica de co-precipitação de íons sulfato em conjunto com os precipitados de alumínio, seguida por etapas de floculação e sedimentação lamelar (processo PF-SL) foi estudada no tratamento de drenagens ácidas e neutras de minas de carvão (DAM e DNM, respectivamente). Os estudos foram conduzidos por um período de 24 meses e os resultados obtidos em regime contínuo indicaram que a remoção de SO4-2 foi inferior aos dados obtidos em laboratório via filtração devido à competição entre os íons em condições naturais (efeito matriz). A concentração final de íons sulfato foi de 410 e 520 mg.L-1 (remoção de 72% e 68%) no tratamento de DAM e DNM, respectivamente, quando a concentração inicial de SO4-2 nesses efluentes foi em torno de 1600 mg.L-1. O volume de lodo gerado na aplicação do processo PF-SL em estudos contínuos representa um aspecto importante a ser estudado, embora a massa seja em pouca quantidade. Entretanto, em função dos elevados teores de alumínio no lodo, a utilização desse material como fonte de matéria-prima para indústrias química e da construção civil pode ser considerada. A remoção de íons metálicos como o manganês e alumínio foi possível via um segundo estágio de tratamento a pH 9,0 e filtração em bancada, em função da solubilidade dos hidróxidos dos respectivos metais em valores de pH moderadamente ácido. De acordo com o procedimento de projeto elaborado para implementação da técnica para o tratamento de DNM da indústria de carvão, os custos envolvidos na aplicação da técnica foram de aproximadamente R$ 2,50.m-3, valores inferiores aos aplicados em tecnologias atuais para remoção de íons sulfato de efluentes. Os resultados obtidos neste trabalho permitiram estabelecer que a técnica de co-precipitação dos íons sulfato com sais de alumínio, em pH 4,5, e posterior separação dos sólidos suspensos da solução via filtração ou floculação-sedimentação lamelar apresenta um elevado potencial como futuro processo de controle de águas com elevadas concentrações de sulfato. / This work aimed to study the basic aspects involved in chemical interactions (co-precipitation and adsorption) between aluminium species and sulphate ions in acid aqueous solutions and to apply this technique to immobilize the anion in wastewater treatment models. The studies were developed using commercial polyaluminium chloride (CPA) and aluminium chloride solutions (AlCl3.6H2O - analytical reagent purity) at different pH values and under different molar ratios between aluminum ions and sulphate ions (α). The mechanisms of these physical and chemical interactions (adsorption and co-precipitation) were investigated from the distribution of species monomeric, polymeric and aluminum hydroxide in solution (speciation of Ala, Alb and Alc, respectively) held by Ferron method and characterization of precipitates generated through the techniques of dynamic light scattering, laser diffraction, scanning electron microscopy (SEM), energy dispersive X-ray (EDS), X-ray diffraction and fluorescence X-ray. The results showed that high levels of Alb and Alc species were generated in moderately acidic solutions, pH between 4.5 and 5.0. These species presented electrokinetic potential, in the zeta plan, strongly positive at pH 4.5 (greater than +35 mV), reduced to +24 mV in the presence of sulphate ions, and this feature of the precipitates resulted in a strong immobilization of sulphate ions at pH 4.5, higher than 85% when the initial concentration was 1800 mg SO4-2.L-1. This interaction proved to be chemical in nature due to the change in the isoelectric point of the precipitated aluminum, pH 9.3 to pH 8.5, i.e., it was found that the anion was incorporated into the inner Helmholtz plane of the precipitated Al-sulphate. However, increasing the pH of the solution resulted in partial leaching of the anion of the precipitate Al-sulphate, a phenomenon that is explained by the physical adsorption mechanism. Size analysis showed that species of aluminum in water shows size distribution of up to 50 micron, visibly separated into two groups: Alb (less than 5 mm) and Alc (greater than 8 and less than 50 micron). However, Alb species were aggregated in the presence of sulphate ions, exclusively at pH 4.5, due to the mechanism of co-precipitation of these anions. The solids generated from the co-precipitation of sulphate ions with aluminium species showed characteristic amorphous and the formation of this precipitate resulted in an increase of 30% in the immobilization of aluminium species. Another important aspect of interaction in Al-sulphate was the basicity (molar ratio OH / Al) of aluminum salts due to the degree of polymerization of the species of metal cation. The best results of immobilization of sulphate ions were obtained at a basicity equal to 2.2. Similarly, the use of CPA, due to the presence of aluminum species pre-polymerized resulted in greater immobilization of sulphate ions compared to the use of aluminium chloride. However, the final concentration of chloride ions in solution was greater than 1000 mg.L-1, indicating the need to explore other sources of aluminum-free chlorine in its composition, replacing the CPA and aluminium chloride. Other anions such as phosphates, chromates and molybdates showed a similar affinity with species of aluminium at pH 4.5. The application of the technique of co-precipitation of sulphate ions onto aluminium precipitates, followed by flocculation and lamella settling (PF-LS process) was studied in the treatment of acid and neutral acid drainage from coal mines (AMD and NMD, respectively). The studies were conducted for a period of 24 months and the results indicated that in continuous removal of SO4-2 was lower than the laboratory data obtained via filtration due to competition between ions in natural conditions. The final concentration of sulphate ions was 410 and 520 mg.L-1 (removal of 72% and 68%) in the treatment of AMD and NMD, respectively, when the initial concentration of SO4-2 in these effluents was around 1600 mg.L-1. The amount of sludge generated by the application of PF-LS process represents a environmental aspect that must be investigated in the future. However, due to the high content of aluminium in the sludge, the use of this material as a source of raw material for chemical and building industries can be considered. The removal of metal ions such as manganese and aluminum was possible via a second stage of treatment at pH 9.0 and filtration bench, due to the high solubility of hydroxides of the respective metals in moderately acid pH values. According to the operating procedure developed to implement the technique for the treatment of NMD in a site of the coal industry, the costs involved in application of the technique were approximately R$ 2.50.m-3, this value is lower than those applied to current technologies to removal of sulphate ions from effluents. The results of this study indicated that the technique of co-precipitation of sulphate ions with aluminum salts, at pH 4.5 and further separation of suspended solids from solution via filtration or flocculation-lamella settling appears to have a high potential in a future process waste water with high sulphate ions concentration.
315

Técnicas aplicadas ao tratamento e redução dos efluentes líquidos de uma empresa de saneantes domissanitários

Peres, Silvana Drago January 2005 (has links)
A empresa estudada está sediada em Porto Alegre, RS, Brasil, e fabrica produtos de limpeza. Os efluentes provêm das águas de lavagens dos tanques e misturadores de produção, recipientes utilizados na separação de matérias-primas e da lavagem do próprio piso da fábrica, onde ocorrem derramamentos de produtos. Foi implantada uma estação de tratamento de efluentes que opera por processos físico-químicos de coagulação/floculação e adsorção. Entretanto, observou-se que era ineficiente para atender aos parâmetros de qualidade de água exigidos pela legislação. Assim, o objeto deste estudo foi minimizar a geração de efluentes e aperfeiçoar a operação da estação de tratamento dos efluentes líquidos da empresa. A metodologia de trabalho consistiu na caracterização do efluente industrial; monitoramento do desempenho da estação de tratamento de efluentes, implantação de mudanças no processo produtivo para verificar a possibilidade de minimização da geração de efluentes bem como da carga poluidora, e estudo de alternativas de tratamento para melhorar a qualidade da água. Os parâmetros avaliados foram pH, DQO, DBO, fósforo total, nitrogênio total, óleos e graxas, surfactantes, sólidos sedimentáveis e sólidos suspensos. Os resultados demonstram que o efluente apresenta pH alcalino, uma elevada carga orgânica, é rico em nitrogênio e fósforo e possui uma alta concentração de surfactantes. Entretanto, a implantação de um sistema de produção mais limpo, através da programação prévia do processo produtivo, e aplicação de novos procedimentos durante as operações de envase, permitiu que o volume de efluentes gerados diminuísse de 8 m3/dia para 6 m3/dia. A carga de poluente na ETE baixou significativamente, resultando em maior eficiência da estação de tratamento de efluentes. Assim, foi possível atingir, exata ou aproximadamente, todos os parâmetros de emissão padrão. O estudo das alternativas de tratamento também comprovou que o tratamento físicoquímico de coagulação/floculação é mais eficiente quando seguido de um tratamento de adsorção por carvão ativado. A fotocatálise heterogênea, com aplicação de luz UV como forma de polimento ao efluente, reduz substancialmente a quantidade de matéria orgânica e surfactantes presentes no efluente. Os valores da relação DBO/DQO, para o efluente tratado, que variam de 0,29 a 0,34, demonstram a possibilidade de degradação biológica, desde que haja aclimatação ou indução dos microrganismos. Esse fato abre a possibilidade de realizar o tratamento biológico do efluente industrial, misturado ou não ao esgoto cloacal gerado na empresa. / The company studied produces cleaning reagents and is located in Porto Alegre, RS, Brazil. The effluent comes from many washing operations, including equipment and ground cleaning. A physical-chemical treatment plant was installed. It is based on coagulation/flocculation and activated carbon adsorption. However, the treatment operation did not reach the water quality emission standards established by the legislation. Thus, the aim of this work was to minimize the effluent generation and to improve the effluent treatment plant efficiency. The methodology consisted of characterization of the industrial effluent, evaluation of effluent treatment plant, implantation of clean technology procedures and the study of new alternatives for water quality improvement. The parameters analyzed were pH, DQO, DBO, total phosphorous, total nitrogen, oils and greases, surfactants, settable solids, and suspended solids. The results showed that the effluent presents an alkaline pH, a high organic load, is rich in nitrogen and phosphorous, and presents a high concentration of surfactants. However, the implantation of clean technology procedures, by process programming and employees training, allowed a volume reduction from 8 m3/day to 6 m3/day. The load of pollutants was significantly reduced, allowing a better performance of the effluent treatment plant. The emission treatment reached, or became very near the standard. The study of new alternatives also proved that the physical-chemical treatment of coagulation/flocculation is more efficient when followed by an activated carbon adsorption treatment. The use of the TiO2 – photocatalysis process – reduced surfactants concentration in effluent. The BOD/COD relationship, ranged from 0,29 to 0,34, showed that biological degradation is possible, provided that there is microorganism acclimatizing. This fact allows the possibility for the biological treatment of the industrial effluent to be either dumped into the general sewage generated in the company or not.
316

Reúso de água em indústria metalúrgica rolamenteira - estudo de caso da SKF do Brasil Ltda. / Reuse of water in bearing industry - case study of SKF of Brazil Ltda.

Romário Maron Júnior 25 April 2006 (has links)
Com a globalização do mercado, muitas empresas procuraram se modernizar objetivando tornarem-se mais competitivas, com o crescimento industrial os recursos naturais apresentam-se mais escassos levando ao desenvolvimento de leis ambientais cada vez mais rígidas. Os custos envolvidos com o uso dos recursos naturais, têm levado as indústrias a buscarem alternativas a curto e médio prazos para minimizarem estes custos, procurando reduzir os seus impactos ambientais. A busca para um menor consumo de água através de técnicas de reúso e reciclagem nos processos industriais passam a fazer parte do planejamento estratégico de várias empresas, inclusive das rolamenteiras. O presente trabalho foi desenvolvido com o objetivo de avaliar o potencial de reúso da água da atividade de tamboreamento de rolos cônicos com espessura entre 5 a 8 mm e altura de 6 a 8 mm, sendo uma atividade de suma importância para garantir um padrão de qualidade satisfatório, de forma que as atividades subsequentes sejam efetuadas sem anomalias técnicas, conduzindo à obtenção de um produto final de qualidade. Por não requerer uma água com padrões elevados de qualidade, neste trabalho foi demonstrado o potencial de reúso de efluentes na atividade de tamboreamento, viabilizando-se sobre maneira o objeto deste estudo, onde é possível avaliar os aspectos físicos e químicos antes e após o tratamento da água para futura implantação contínua. / With the globalization of the market, many companies had looked for to be modernized for becoming more competitive. With the industrial growth, natural resources scarcity, and environmental pollution result in the development of more stringent laws. The costs associated with the use of the natural resources are taking the industries to search alternatives of short and long terms to minimize these costs looking for the reduction of its environmental impacts. The searching for reduced water consumption through techniques of reuse and recycling in its processes start to be integrated in the strategic planning of some companies including the bearing industry. The present work has been developed with the objective of evaluating the potential of water reuse in the activity of tumbling conical coils with thickness in the range of 5 to 8 mm, and height of 6 to 8 mm, being an activity of utmost importance to guarantee a satisfactory quality standard, in order that the subsequent activities are effected without anomalies, leading to the attainment of an end product of quality. By not requiring water with high standards of quality, in this work the potential of effluent reuse was demonstrated in the activity of tumbling, making possible to achieve the objective of this study, where it was possible to evaluate water physical and chemical aspects before and after the treatment for future implantation in continue way.
317

Síntese e caracterização de membrana condutiva para tratamento de água e efluentes. / Synthesis and characterization of conductive membrane for water and waste water treatment.

Alessandra Piaia 29 August 2017 (has links)
Neste trabalho, foram adicionadas diferentes concentrações de polianilina (PANI) a uma solução polimérica de poliétersulfona (PES) e N-metil-pirrolidona (NMP), com o intuito de sintetizar membranas de ultrafiltração a partir do método de inversão de fases. O desafio consistem em combinar alta condutividade elétrica, boas propriedades mecânicas e oxidação eletroquímica, permitindo assim que a oxidação de possíveis contaminantes ocorra ao mesmo tempo em que a membrana atua como uma barreira de filtração seletiva. O efeito da adição de PANI foi avaliado quanto à morfologia da membrana, capacidade de separação e desempenho, em termos de permeabilidade e condutividade. As membranas modificadas apresentaram uma morfologia muito singular quando analisadas pelo Microscópio Eletrônico de Varredura (MEV), poros maiores foram identificados, ausência da camada seletiva, diminuição da camada inferior e grandes fases aglomeradas ao longo da seção transversal. Devido ao aumento do tamanho dos poros, a seletividade das membranas modificadas foi comprometida. Os resultados de porosidade para as membranas modificadas variaram entre 53 e 66%. A permeabilidade e a condutividade das membranas modificadas aumentaram à medida que a concentração de PANI também aumentou. O fluxo mediano obtido para a membrana com concentração de 40% de PANI foi de 835 L.m-2.h-1, cerca de 5 vezes maior do que o fluxo mediano obtido para a membrana controle. Já a condutividade mediana obtida para a mesma membrana modificada foi de 1,7x10-6 S, cerca de 15 vezes maior do que a membrana controle. Durante o teste de voltametria cíclica não foram observadas reações de oxidação-redução, nem da solução de ferro-cianeto nem da própria polianilina, ao aplicar uma tensão variando entre -0,2 V e 0,8 V. Desta forma, a partir dos resultados, pode-se afirmar que a adição de Polianilina alterou a morfologia e o desempenho das membranas modificadas, destacando o incremento na permeabilidade, hidrofilicidade e condutividade, mantendo sua característica de ser uma barreira de filtração seletiva. / In this work, different concentrations of Polyaniline (PANI) were added to a polymer solution made of Polyethersulfone (PES) and N-methylpyrrolidone (NMP), in order to synthesize ultrafiltration membranes by the phase inversion method and the challenge of combine high electrical conductivity, good mechanical properties and electrochemical oxidation, thus allowing the oxidation of matter to occur at the same time that the membrane acts as a selective and reliable filtration barrier. The effect of PANI addition was evaluated regarding the membrane morphology, separation capacity and performance in terms of permeability and conductivity. The modified membranes presented a very unique morphology when analyzed by the Scanning Electron Microscope (SEM), larger pores were identified, absence of the selective layer, decrease of the lower layer and large agglomerated phases with phase contour characterization along the cross section. Due to the increase in pore size, the selectivity of the modified membranes was compromised. The porosity results for the modified membranes are only reflections of the morphology obtained, and the median porosities varied between 53 and 66%. The permeability and conductivity of the modified membranes increased as the PANI concentration also increased. The median flow obtained for the membrane with 40% PANI concentration was 835 L.m-2.h-1, about 5 times higher than the median flow obtained for the control membrane. The median conductivity obtained for the same modified membrane was 1.7x10-6 S, about 15 times higher than the control membrane. During the cyclic voltammetry test, no oxidation-reduction reactions were observed, neither the iron-cyanide solution nor the polyaniline itself, when applying a voltage ranging from -0.2 V to 0.8 V. From the results, it can be affirmed that the addition of polyaniline particles altered the morphology and performance of the modified membranes, highlighting the increase in permeability, hydrophilicity and conductivity, maintaining its characteristics of being a selective filtration barrier.
318

Tratamento de efluentes contendo fenol através de processos oxidativos avançados (POAs). / Treatment of wastewater containing phenol through advanced oxidation processes (AOPs).

Cínthia Tiemi Muranaka 30 March 2006 (has links)
Os Processos Oxidativos Avançados (POAs) têm sido largamente empregados para o tratamento de efluentes contendo compostos orgânicos altamente tóxicos, que por sua vez, são dificilmente degradados pelos sistemas de tratamento biológico convencional. Além disso, os tratamentos físico-químicos, como filtração, adsorção e floculação, não destroem o composto tóxico, e sim, apenas transferem-no para outra fase, causando um subseqüente problema de descarte. A principal barreira para a aplicação do POA em escala industrial é o alto custo relacionado à utilização da radiação ultravioleta (UV). Desta maneira, torna-se interessante desenvolver um reator com uma fonte artificial de radiação UV de custo reduzido. Neste trabalho, foi projetado um reator tubular fotoquímico de aço inox 304 que apresenta um conjunto de 12 lâmpadas fluorescentes como fonte de radiação UV (40W/lâmpada), posicionadas verticalmente na superfície interna do mesmo. O processo estudado foi o processo foto-Fenton, que consiste em uma combinação de íons ferrosos, peróxido de hidrogênio e radiação UV, aplicado na degradação de um efluente aquoso contendo fenol como poluente modelo (100–500 mgC.L-1). Os resultados experimentais indicaram que a taxa de degradação aumenta com a radiação UV, até atingir a saturação de fótons da luz UV . Com o objetivo de verificar a influência das variáveis de processo, foi realizado um planejamento experimental, no qual possibilitou-se obter um modelo para o processo e a respectiva superfície de resposta. Neste processo foi utilizada uma combinação de Fe2+ (0,27–30 mM), H2O2 (0,2–6 moles) e radiação UV, chegando-se a uma mineralização de 82% para 100 mgC.L-1 de fenol e 81% para 500 mgC.L-1 de fenol. Devido à complexidade apresentada pelo processo foto-Fenton, foi aplicado outro tipo de modelagem matemática, baseado na técnica de redes neurais artificiais (RNA), chegando-se a um coeficiente de determinação de 99% entre os valores experimentais e os valores calculados pelo modelo. / Advanced Oxidation Processes (AOPs) have been largely used for the treatment of wastewaters containing highly toxic organic compounds, which are hardly degraded by the conventional biological systems. Besides, the physicalchemical treatments, such as filtration, adsorption and flocculation, do not destroy the target compounds, which are simply transferred to another phase, causing a subsequent problem of disposal. The main barrier for the application of the POA in industrial scale is the high cost related to the use of ultraviolet radiation (UV) sources. Therefore, it has been proposed a development of a reduced cost reactor with an artificial source of UV radiation. In the present work, a tubular photochemical reactor was developed, which is made in stainless steel and presents a row of 12 fluorescent lamps as the UV radiation source (40W/lamp), attached vertically onto the inner surface of the reactor. It has been studied the photo-Fenton process, that consists in a combination of ferrous ions, hydrogen peroxide and UV radiation, applied in the degradation of an aqueous solution containing phenol as pollutant model (100–500 mgC.L-1). The experimental results indicated that the degradation rate increases as the UV irradiance increases. In order to verify the influence of the process variables in phenol degradation, an experimental design was carried out by the response surface method and the corresponding polynomial model was determined. In this process, it was used a combination of Fe2+ (0,27–30 mM), H2O2 (0,2–6 moles) and UV radiation. The mineralisation efficiency was 82% for phenol 100 mgC.L-1 and 81% for phenol 500 mgC.L-1. Due to the complexity presented by the photo-Fenton process, another type of mathematical modelling was applied, based on the artificial neural network (ANN), obtaining 99% of coefficient of determination between the experimental values and the values calculated by the model.
319

Banhados construídos como sistema terciário para reúso da água industrial em uma empresa metal-mecânica

Curia, Ana Cristina January 2010 (has links)
Com a poluição dos recursos hídricos e o substancial aumento do custo com água, o reúso da água tornou-se uma alternativa a ser considerada nas operações industriais. Essa iniciativa pode auxiliar na busca de uma solução para problemas de escassez de recursos hídricos e na diminuição de custos operacionais das empresas. O problema a ser abordado neste estudo está relacionado com as dificuldades técnicas do tratamento de efluentes para atingir a qualidade necessária ao reúso da água e a necessidade de atender os padrões de lançamento de efluentes estabelecidos pela legislação ambiental tendo em vista a impossibilidade de reúso total do efluente tratado. O principal objetivo deste trabalho foi estudar a remoção de poluentes gerados em uma indústria metal-mecânica por meio de plantas aquáticas em escala piloto e industrial e avaliar o potencial de reúso do efluente como água industrial em diferentes aplicações (descarga de vaso sanitário, irrigação paisagística, torre de resfriamento, lavagem de equipamentos, usinagem de peças e água de incêndio). Para este estudo foram projetadas e construídas uma planta piloto e outra planta em escala industrial em uma empresa situada na região metropolitana de Porto Alegre. O sistema foi constituído por um banhado construído como sistema terciário para simular as condições de tratamento do efluente industrial. As macrófitas foram acondicionadas em tanques de polietileno com capacidade total de 1 m3 considerando o tratamento de efluente de 2 m3/dia. O efluente circulou com um fluxo sub-superficial horizontal através da matriz porosa de areia grossa e brita, na quais estavam presentes as raízes das macrófitas das espécies Junco (Scirpus sp.) e Taboa (Typha sp.). A planta em escala industrial foi executada seguindo os mesmos padrões da planta piloto, porém, com algumas modificações. A planta industrial é constituída de 4 lagoas de fluxo sub-superficial horizontal com dimensões idênticas de 11,50 m de largura, 7,0 m de comprimento e 0,8 m de profundidade útil; camada suporte composta de brita zero; construção das lagoas com argila compactada; uso das espécies Junco (Scirpus sp.) e Taboa (Typha sp.) nas quatros lagoas de forma intercalada; estação de bombeamento e rede para o reúso do efluente tratado. O estudo de tratabilidade da planta em escala piloto e industrial foi realizado por monitoramento dos parâmetros físico-químicos e biológicos. Mesmo com algumas variações de carga e problemas operacionais, o sistema apresentou um comportamento adequado para a remoção de poluentes na planta piloto/ industrial, cujos resultados médios de eficiência de remoção foram de 73%/49%, 61%/42%, 56%/46%, 54%/49%, 57%/46% e 66%/69% de fósforo total, NTK, NH4-N, DQO, DBO, SS, respectivamente. As análises da camada suporte em conjunto com o sistema radicular e parte aérea apontam um possível potencial de emprego destes resíduos no solo como adubo devido a sua composição. O sistema de tratamento com banhado construído para reúso da água mostrou ser efetivo para redução de custos cujo período de payback médio é de 4,5 anos. Durante o experimento foi possível verificar que o reúso de água consiste em uma estratégia de sustentabilidade para redução do consumo de água potável (economia de 18 % em média e 44% máxima do consumo total). / With the pollution of water resources and the substantial increase in the cost of water, water reuse has become an alternative to be considered in industrial operations. This initiative can support in finding a solution to problems of scarcity water resources and minimizing operating costs in the companies. The problem to be considering in this study is related to the technical difficulties of treating effluent to aiming the quality necessary for water reuse and the need to reach effluent discharge standards set by environmental legislation considering the impossibility of total effluent treated reuse. The objective of this work was to study the pollutants removal generated in a metalworking industry effluent by aquatic plants in pilot and industrial scales and evaluate the potential for effluent reuse as industrial water in different applications (flushing, landscape irrigation, cooling tower, vehicles washing, machining of parts and firefighting). A pilot plant was built in an industry consisting of a constructed wetland as a tertiary system to simulate the conditions of treatment of an industrial effluent. The macrophytes were conditioned in polyethylene tanks with a total capacity of 1 m3 foreseeing the treatment of 2 m3/day. The effluent circulated in a horizontal subsurface flow through a porous matrix of thick sand and gravel in which the roots of macrophytes of the species Reed (Scirpus sp.) and Cattail (Typha sp.) were developed. The industrial scale plant was executed following the same standards by the pilot plant with some modifications. The industrial plant was composed by four horizontal sub-surface flow lagoons with equal dimensions of 11m width, 7m length and 0.8m useful depth; a support layer composed by gravel; lagoons with compacted clay; Reed (Scirpus sp.) and Cattail (Typha sp.) aquatic plant were interchangeably introduced in the four lagoons; pump station and network of pipes for the reuse of the treated effluent. The study of the treatment was carried out by monitoring of the physical-chemical and biological parameters. Even though some operational load variations and operational problems, the system showed an adequate behavior for the removal of pollutants, in pilot and industrial scales whose the average removal efficiency results were 73%/49%, 61%/42%, 56%/46%, 54%/49%, 57%/46% e 66%/69%, respectively. The analyses of the support layer with the root system and aerial part of the plant pointed out a possible potential of use of these wastes in the ground as fertilizer due to its composition. The constructed wetland treatment system for reuse of water showed to be effective for reduction of costs and the payback is very attractive (4.5 years). During the experiment it was possible to verify that reuse of water is a useful sustainability strategy to reduction of utilization of drinking water in industrial operations (saving of 18 % in average and 44% maximum of total consumption).
320

Avaliação do processo de eletrodiálise reversa no tratamento de efluentes de refinaria de petróleo

Machado, Mara de Barros January 2008 (has links)
Este trabalho teve como objetivo avaliar a aplicação da eletrodiálise reversa no tratamento de efluente final de refinaria para reuso em sistema de resfriamento. O estudo foi conduzido nas instalações da Refinaria Gabriel Passos (REGAP)- MG, com efluente real, proveniente da saída da Estação de Tratamento de Despejos Industriais (E.T.D.I.), e utilizando para os testes uma unidade-piloto de eletrodiálise reversa com capacidade de tratamento de 2 m3/h. A utilização do processo de dessalinização por EDR teve o objetivo de reduzir sólidos totais dissolvidos no efluente de aproximadamente 1.240 mg/L para 310 mg/L, o que equivale a cloretos de 460 mg/L e 100 mg/L respectivamente, para atingir a qualidade requerida para água de make-up da torre de resfriamento da REGAP. Inicialmente foi feita uma avaliação comparativa com o processo de osmose inversa, no qual foi constatada, com o uso da EDR, a maior continuidade operacional, menores problemas de incrustação e menor exigência para o pré-tratamento do efluente. No estudo com a EDR foram realizados testes variando-se a vazão, de 600 a 2000 L/h de produto; voltagem de 200 a 370V e número de estágios. Durante os testes foi realizado o monitoramento operacional e analítico da água de alimentação da EDR, do produto (solução diluída) e do rejeito (concentrado salino), sendo os dados avaliados e correlacionados para determinação da densidade de corrente, taxa hidráulica, eficiência e taxa de remoção de sais. A análise da formação de incrustações e deposições na superfície das membranas levou ao estabelecimento de um procedimento de limpeza química. O estudo foi conduzido de forma a obter a otimização da operação com rendimento necessário na remoção de sólidos dissolvidos, menor custo energético e de manutenção. Após os testes foi selecionada a condição otimizada da unidade piloto: módulo em 2 estágios, vazão de 1,1 m3/h e voltagem de 275V. Para este condição o consumo energético foi de 1,95 KWh/m3 de efluente tratado. Os resultados mostraram a viabilidade técnica-econômica do uso da EDR para remoção de sais de efluente final de refinaria para aplicação em reposição de sistemas de resfriamento. / This study aimed the evaluation of the application of electrodialysis reversal in final effluent treatment targeting the reuse in cooling towers. The study was done in Gabriel Passos Refinery (REGAP) - MG, with real effluent, from the Industrial Effluent Treatment Station (ETDI), and was held in a pilot plant of electrodialysis reversal with a treatment capacity of 2 m3 / h. The use of the desalination process with EDR target the reduction of total dissolved solids in the effluent of about 1.240 mg / L to 310 mg / L, equivalent to chlorides of 460 mg / L and 100 mg / L respectively, to reach the required quality of make-up water in the REGAP cooling tower. It was originally done a comparative evaluation with reverse osmosis process, another method of membrane desalination. Electrodialysis was selected because of its operating stability, less problems with scaling and fouling, dispensing the use of conditioning chemicals, and the requirement of a simpler pre- treatment The tests with EDR were carried out ranging the product flux for 600 to 2.000 L/h, the voltage for 200 to 370V and the number of hydraulic stages. During the tests were analyzed operational and analytical data in the EDR feed, product (diluted solution) and reject (concentrated solution), being the parameters analyzed and correlated to determine the current density, hydraulic rate, efficiency and salts removal rate. The analysis of fouling and deposition formation on the membranes surface led to an establishment of a chemical cleaning procedure. This study was conducted in order to obtain the operational optimizing with the necessary income to remove dissolved solids, with lower energy cost and maintenance. After the tests was selected the optimum condition for the pilot plant: stack in 2 stages, flow rate of 1.1 m3/h and voltage of 275V. In this condition the power consumption was 1.95 KWh/m3 of treated effluent. The results showed the technical and economic feasibility for the EDR in removing salts from refinery effluents for reuse in make up of cooling systems.

Page generated in 0.1158 seconds