• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5783
  • 109
  • 97
  • 84
  • 84
  • 83
  • 55
  • 37
  • 29
  • 21
  • 21
  • 18
  • 3
  • 3
  • 1
  • Tagged with
  • 6029
  • 3373
  • 2538
  • 1559
  • 1414
  • 1184
  • 959
  • 777
  • 749
  • 729
  • 672
  • 662
  • 615
  • 611
  • 525
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
721

Estudo de qualidade da energia: dimensionamento de um restaurador dinâmico de tensão

FONSECA, Luiz Carlos de Alcântara January 2003 (has links)
Made available in DSpace on 2014-06-12T17:40:34Z (GMT). No. of bitstreams: 2 arquivo7028_1.pdf: 1207436 bytes, checksum: 2289a93287ee8e2dc072a0d2464000ee (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2003 / Com o desenvolvimento da microeletrônica e da eletrônica de potência, as cargas dos sistemas de potência estão se tornando cada vez mais sensíveis a variações momentâneas de tensão. Essas variações, mesmo que momentâneas, podem provocar paradas ou mau funcionamento em processos industriais, causando prejuízos consideráveis. Desta forma, é natural o crescente interesse em estudar alternativas para melhorar a qualidade da energia elétrica ofertada, com a redução dos afundamentos momentâneos de tensão, seja através da adição de reforços nas redes de transmissão e distribuição, seja pela introdução de equipamentos próximos à carga desenvolvidos especificamente para mitigar afundamentos de tensão. Esta dissertação apresenta um estudo das alternativas para a mitigação de afundamentos momentâneos de tensão, descrevendo detalhadamente o Restaurador Dinâmico de Tensão e apresentando um programa computacional para seu dimensionamento. Realiza-se também um estudo de caso para avaliar a viabilidade econômica da aplicação de um restaurador dinâmico de tensão junto a um consumidor específico
722

Avaliação da efetividade do Laser Terapêutico e TENS na diminuição da dor em pacientes com lombalgia / Evaluation of the effectiveness of Therapeutic Laser and TENS in the reduction of pain in patients with low back pain

Chagas Júnior, Rainier Antonio Queiroz [UNESP] 17 December 2016 (has links)
Submitted by RAINIER ANTONIO QUEIROZ CHAGAS JUNIOR (DINTER) null (rainierqueiroz@hotmail.com) on 2017-02-13T13:41:32Z No. of bitstreams: 1 Tese Rainier Final 2017.pdf: 540510 bytes, checksum: e059773a2d31721deaeccfff339b16b8 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2017-02-13T18:49:53Z (GMT) No. of bitstreams: 1 chagasjunior_raq_dr_araca.pdf: 540510 bytes, checksum: e059773a2d31721deaeccfff339b16b8 (MD5) / Made available in DSpace on 2017-02-13T18:49:53Z (GMT). No. of bitstreams: 1 chagasjunior_raq_dr_araca.pdf: 540510 bytes, checksum: e059773a2d31721deaeccfff339b16b8 (MD5) Previous issue date: 2016-12-17 / Chagas Júnior, RAQ. Avaliação da efetividade do Laser Terapêutico e TENS na diminuição da dor em pacientes com lombalgia. [Tese]. Araçatuba: Universidade Estadual Paulista (Unesp), Faculdade de Odontologia; 2016. Introdução: A lombalgia é frequentemente acompanhada por exacerbação da dor e diminuição da capacidade funcional. Muitas terapias não farmacológicas como laser e TENS são indicadas para o seu tratamento, mas seus efeitos não estão completamente esclarecidos. Objetivo: analisar o efeito de diferentes modalidades terapêuticas (laser e TENS) no alívio da dor crônica lombar não-específica observando-se o número de sessões clínicas. Método: A amostra foi composta por 30 pacientes randomicamente selecionados e divididos em 2 grupos tratados por duas modalidades terapêuticas: G1 – laser (n=15), G2 – TENS (n=15). Todos os pacientes foram avaliados antes e após tratamento, pelo Questionário McGill de dor (MPQ), e Capacidade Funcional pelo Questionário de Roland Morris. E avaliados diariamente pela Escala Visual Analógica (EAV). Por esta metodologia foi possível concluir que as intervenções propostas diminuem de forma estatisticamente significante a intensidade da dor a curto prazo em pacientes com dor lombar, alteram a percepção dos descritores de dor apenas no Grupo Laser pré e pós-tratamento; Assim como alteram os relatos de incapacidade física. / Chagas Júnior, RAQ. Evaluation of the effectiveness of Therapeutic Laser and TENS in the reduction of pain in patients with low back pain. [Thesis]. Araçatuba: São Paulo State University (Unesp), School of Dentistry; 2016. Introduction: Low back pain is often accompanied by exacerbation of pain and decreased functional capacity. Many non-pharmacological therapies such as laser and TENS are indicated for its treatment, but their effects are not fully understood, nor is the minimum number of sessions for therapeutic effect. Objective: To analyze the effect of different therapeutic modalities (laser and TENS) non-relief of chronic non-specific chronic pain by varying the number of clinical sessions. Methods: The sample consisted of 30 patients randomly selected and divided into 2 groups treated by two therapeutic modalities: G1 - laser (n = 15), G2 - TENS (n = 15). All patients were assessed before and after treatment, by the McGill Pain Questionnaire (MPQ), and Functional Capacity by the Roland Morris Questionnaire. And evaluated daily by Visual Analog Scale (EAV). By this methodology it was possible to conclude that the proposed interventions statistically reduce the short-term pain intensity in patients with low back pain, alter the perception of the pain descriptors only in the Laser Group before and after treatment; Just as they alter the reports of physical incapacity
723

Aplicação da teoria de potência conservativa para monitoramento do comportamento do motor de indução trifásico sob distúrbios de qualidade de energia /

Abreu Junior, Breno Antonio Ribas de. January 2015 (has links)
Orientador: Flávio Alessandro Serrão Gonçalves / Banca: Moacyr Aureliano Gomes de Brito / Banca: Paulo Amaral Serni / Resumo: Essa dissertação tem por objetivo investigar o comportamento dos parâmetros do motor de indução trifásico (MIT) com rotor tipo gaiola de esquilo, potência mecânica nominal de 3 HP, 220 V, 4 pólos, 60 Hz através das variáveis propostas pela Teoria de Potência Conservativa (CPT), operando sob condições de distúrbios de qualidade de energia. Inicialmente foram determinadas algumas condições de distúrbios, baseadas no Módulo 8 do PRODIST da ANEEL, envolvendo distorções harmônicas de tensão (harmônicas de 3º, 5º e 7º ordem com aplitudes de 6,5%, 7,5% e 6,5% da fundamental respectividade), desequilíbrio de tensão (fator de desequilíbrio de 2% na amplitude, assimetria e ambos), afundamento de tensão (50% da amplitude nas três fases para 5 e 30 ciclos da frequencia da rede) e elevação de tensão (incremento de 50% na amplitude das tensões para 5 e 30 ciclos). Esses distúrbios foram aplicados na alimentação de um motor de indução trifásico em condição de regime permanente com conjugado nominal de carga. O modelo do MTI é representado através da transformação das variáveis de estator e rotor para os eixos d-q num plano de referência síncrono, sendo possível assim verificar o comportamento dinâmico dessa máquina nessas condições. Toda estrutura de simulação e aquisição de dados foi desenvolvida no software PSIM. Através das simulações foi possível avaliar o comportamento dos índices da CPT e a relação existente entre alguns índices e os parâmetros do motor / Abstract: This dissertation aims to investigate the behavior of three-phase induction motor parameters (MIT) with squirrel cage rotor, mechanical nominal power of 3 HP, 220 V, 4poles, 60 Hz using the variables proposed by the Conservative Power Theory (CPT), operating under conditions of power quality disturbances. initially some disturbance conditions were determined, based in Module 8 of PRODIST ANEEL, involving voltage harmonic distortion (harmonic 3rd, 5th and 7 th order with amplitudes of 6,5% 7.5% and 6.5% of the fundamental respectively), voltage imbalance (2% amplitude imbalance factor, asymmetry, and both), sag (50% of the amplitude in the three phases for 5 and 30 cycles of the mains frequency), and voltage increase (increment 50% in the amplitude of the voltages for 5 and 30 cycles). These disorders were applied to a three-phase induction motor in steady condition with rated torque lead. The MIT model is represented by the transformation of the stator and rotor variables for the dq axes in an synchronous reference frame, permiting the check of the dynamic behavior of this machine in these conditions. Every simulation structure and data aquisition was developed in PSIM software. Through simulations it was possible to evaluate the behavior of the indices of CPT and relationship between some indices and machine parameters / Mestre
724

Morfologia e hidrodinâmica em rios multicanais ("anabranching") : exemplo do alto rio Paraná /

Gon, Priscila Panzarini. January 2012 (has links)
Orientador: José Candido Stevaux / Banca: Maximiliano Bayer / Banca: Fabiano Tomazini da Conceição / Resumo: A dinâmica do escoamento fluvial é importante para a compreensão das forças atuantes no funcionamento dos processos morfogenéticos fluviais, seja na fase de erosão, de transporte ou de sedimentação. Os rios classificados como multicanais (anabranching) apresentam um diversificado grupo de rios aluviais abrangendo canais múltiplos e interconectados separados por ilhas aluviais grandes e estáveis, que dividem o fluxo. O estudo de parâmetros hidráulicos assim como o transporte e deposição de sedimentos em rios classificados como multicanais torna-se importante uma vez que esse tipo de padrão é o mais frequente nos sistemas fluviais de grande porte. O presente trabalho visa estudar a distribuição de energia, e da carga de fundo bem como a morfologia em um trecho multicanal do alto rio Paraná. A bacia do rio Paraná é a segunda maior bacia hidrográfica da América do Sul, com uma área 3,1milhões de km², cuja drenagem principal (rio Paraná e o seu formador rio Grande) tem cerca de 3.965 km. O trecho de estudo compreende uma extensão de 53 km delimitada por dois pontos em que o rio escoa através de um único canal: a montante Porto São José e a jusante Porto 18, que possuem uma vazão de margens plenas em torno de 17780 m³/s. O estudo foi feito com a medição de parâmetros hidráulicos e coleta de material de fundo, no trecho multicanal e nos pontos nodais para efeito de comparação, os dados foram tratados por meio de estatísticas, gerando tabelas, gráficos e mapas, que demonstram como a energia está sendo distribuída neste sistema. No trecho de estudo foram encontrados até 6 canais secundários que o fluxo pode se dividir. A relação alta de largura/profundidade desses canais tende a diminuir quando o número de canais aumenta, ao contrário do que acontece com a potência específica de... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The dynamics of river flow is important for understanding the forces acting on the functioning of river morphogenetic processes in the erosion, transport and sedimentation phases. Rivers classified as anabranching constitutes a diverse group of alluvial rivers with multiple channels separated by large and stable alluvial islands that divide the flow. The study of hydraulic parameters as well as the transport and deposition of sediments in rivers classified as anabranching since this type of pattern is most common in large river systems. The present work aims to study the morfology, energy distribution, and bed load distribution in a multichanneled reach of the upper Paraná River. The Paraná basin is the second largest river basin in South America, with an area of 3.1 million square kilometers, whose main drain (Paraná River and its former Rio Grande) is about 3965 km. The study includes a anabranching stretch of 53 km extension defined by two node-points, from Porto de São José to Porto 18, State of Paraná, Brazil. The bankfull discharge at this reach is 17 780 m³/s. The study measured the hydraulic parameters and collected bed load in all chanels of the multichanelled stretch. Data were analyzed and compared statistics generating tables, graphs and maps. It was possible to observe, how-energy is being distributed in this system. Were found up to six secondary channels that flow can be divided. The high ratio width / depth of these channels tend to decrease when the number of channels increases unlike what happens with the stream power specific. So it's possible to conclude that the division of the channel by the formation of islands produces... (Complete abstract click electronic access below) / Mestre
725

Estudo da viabilidade do uso do pó de aciaria elétrica a arco na confecção de blocos de concreto para pavimentação

Vargas, Alexandre Silva de January 2002 (has links)
o Pó de Aciaria Elétrica (PAE) é um resíduo gerado em indústrias siderúrgicas que utilizam o Forno Elétrico a Arco (FEA) e a sucata como principal matéria-prima para a produção do aço. O PAE é composto por diferentes óxidos metálicos, entre eles o Zn, Cr, Pb e Cd. Devido às concentrações de Pb e Cdultrapassarem as pennitidas pela NBR 10004(1987), no ensaio de lixiviação, o PAE é classificado como resíduo perigoso Classe I. Este trabalho tem como objetivo o estudo da influência do PAEno desempenhomecânico e durabilidade de blocos de concreto para pavimentação. O programa experimental foi desenvolvido em duas etapas: a primeira. na qual foi fixada a relação água/cimento e a segunda, na qual foi fixado o índice de umidade, fator este relacionado com a capacidade de moldar os corpos-de-prova. Em ambas as etapas, o teor de adição do PAE empregado foi de 5%, 15% e 25% em relação à massa de cimento. Também foram moldados corpos-de-prova sem adição do resíduo (0%), utilizados como referência. Como ensaios complementares, foram detenninados o calor de hidratação, assim como a caracterização mineralógica e microestrutural de pastas de cimento com teores do PAE. Verificou-se que, nas duas etapas, os blocos contendo 15% de adição do PAE obtiveram melhor desempenho quanto à resistência à compressão axial. Para os ensaios de durabilidade, os blocos com o PAE mostraram-se com desempenho igual ou superior aos blocos que não o possuíam O PAE utilizado nos blocos de concreto, bem como em pastas de cimento, retardou os tempos de início e fim de pega. O cimento também pode agir como formador de uma matriz para encapsular os metais pesados contidos no pó de aciaria. Nos ensaios de caracterização ambiental, obselVou-seeste encapsulamento através da análise dos extratos lixiviados e solubilizados, onde as concentrações dos metais pesados, ao longo do tempo, diminuíram. Isto fez com que os blocos, contendo o resíduo em sua composição, fossem classificados neste trabalho como Classe II - não-inerte. Desta forma, a partir de um resíduo perigoso Classe L foi possível desenvolver, através do encapsulamento na matriz cimentante, um produto Classe 11.
726

A comercialização de energia no novo setor elétrico brasileiro

Dalmolin, Bruno January 2001 (has links)
O mundo passa por profundas mudanças no que se refere ao papel do Estado. As economias apresentam um crescente aumento da participação privada em setores originalmente estatais com a abertura comercial e a desregulamentação de algumas atividades econômicas contribuindo para a diminuição da participação do Estado como empresário. Neste novo ambiente econômico, as políticas públicas de estímulo à concorrência passam a ter um papel fundamental, garantindo que o mercado possa alocar eficientemente os recursos dentro da economia. É neste contexto que os debates em torno da reorganização da indústria de energia elétrica ganharam forte impulso, com diversos países passando por processos de reforma na estrutura de suas respectivas indústrias, bem como as instituições e regulamentos que controlam o funcionamento das mesmas. A reestruturação do setor elétrico brasileiro objetiva, em tese, promover a competição em alguns mercados, transformando alguns segmentos de regime monopolista em competitivo. Isto vem acarretando a formação de um novo paradigma, influenciado pela mudança da gestão das empresas, de pública para privada, e pela inserção da regulamentação que vise a promover a eficiência das companhias naqueles segmentos onde o mercado é cativo. Assim, este trabalho propõe-se a contribuir com o debate acerca da reforma da indústria de energia elétrica (IEE) do Brasil, discutindo, entre outros pontos, a introdução da comercialização e o conflito existente entre reestruturação industrial e seu processo regulatório. Procurou-se identificar as possíveis fontes de ineficiência, decorrentes da proposta da consultoria britânica Coopers & Lybrand, do novo modelo para o setor elétrico brasileiro. Analisaram-se as teorias de Mercados Contestáveis, de Custos de Transação e de Estrutura-Conduta- Desempenho, procurando a que melhor interpreta e/ou avalia os possíveis efeitos, vantagens e desvantagens da proposta de mudança estrutural e regulamentar da IEE do Brasil. Neste contexto, o trabalho conclui que a Economia dos Custos de Transação é a mais adequada para essa finalidade, pois apresenta condições que permitem avaliar o problema tanto sob a ótica da adequabilidade da nova estrutura de governança quanto do ponto de vista das relações comerciais, o que é de fundamental importância para o entendimento do processo, não sendo possível atender, em sua totalidade, aos questionamentos inerentes à situação com base nas teorias de Mercados Contestáveis e Estrutura-Conduta-Desempenho. O trabalho inclui, também, uma análise sobre a comercialização da energia elétrica, sujeita às incertezas do setor, que combina as teorias matemáticas e econômicas de última geração para obter uma representação realista do sistema e oferecer ao agente de decisão um auxílio preciso e confiável.
727

Estratégias para minimizar o consumo de energia elétrica no apoio a sistemas solares de aquecimento de água

Vieira, Luiz Rosa January 2001 (has links)
É muito difícil falar sobre aquecimento de água usando energia solar, sem falar em energia de apoio, ou auxiliar. Essa indispensável energia auxiliar, que pode ser eletricidade, gás ou um outro combustível qualquer, tem por objetivo substituir a energia solar nos dias nublados, ou complementá-la nos períodos de baixa radiação solar. Sua finalidade é manter um certo volume de água quente dentro das condições mínimas de temperatura para uso imediato. Essa energia, tão importante para a eficácia do sistema, tem sempre um custo agregado que deve ser considerado no projeto. A escolha do tipo de energia auxiliar recai justamente sobre a eletricidade por sua facilidade de controle e baixo investimento inicial. O custo da energia elétrica, contudo, é hoje alto o suficiente para que a fração elétrica no consumo de energia do sistema seja importante e passe a merecer mais atenção. Esta dissertação visa a estudar estratégias para minimizar o consumo de energia elétrica auxiliar. O trabalho foi desenvolvido através da simulação do atendimento de uma residência unifamiliar, habitada por cinco pessoas, com um consumo de água quente variável ao longo do dia e igual para todos os dias do ano. Empregou-se para as simulações de todos os casos estudados, o software TRNSYS em sua versão 14.2, (KLEIN, 1997) que demonstrou eficácia e coerência nos resultados obtidos Ao longo do trabalho foram simulados mais de setecentos casos, variando-se parâmetros como área de coletores, volume do reservatório, potência elétrica, dentre outros. Com os resultados obtidos nas simulações foram elaboradas tabelas e gráficos dos quais foi possível retirar algumas conclusões relevantes tais como a dependência do consumo de energia auxiliar com o volume do reservatório, número de coletores, potência da resistência de aquecimento e sua altura, bem como a altura do termostato. A partir dos resultados deste trabalho foi possível a elaboração de uma série de recomendações relativas a estudo e a projeto de sistemas de aquecimento solar de água quente para uso doméstico, visando à otimização na utilização do sistema de energia auxiliar.
728

Proposta para implantação de microcentrais hidrelétricas automatizadas com o emprego de geradores assíncronos

Santos, Sérgio Roberto dos January 2003 (has links)
Este trabalho insere em seu conteúdo dois propósitos: o primeiro é o de apresentar uma microusina experimental, uma planta piloto de uma microcentral hidrelétrica automatizada, que foi montada para ser utilizada como laboratório de pesquisas do desempenho de máquinas assíncronas de até 5CV operando como geradores de energia elétrica. Para isso, apresentamos todos os equipamentos com as suas respectivas especificações, a descrição do funcionamento e documentos gerais do projeto. O segundo é fazer uma revisão do uso da máquina assíncrona, funcionando como gerador de energia elétrica ligada à rede de distribuição local. Estudamos e apresentamos algumas conclusões sobre o comportamento deste tipo de gerador, no contexto de uma microcentral hidrelétrica automatizada, em situações operacionais onde se pode contemplar máxima potência ou máximo fator de potência ou, então, máximo rendimento. Realizamos análises teóricas considerando o circuito equivalente do gerador instalado na microcentral; foram geradas curvas das grandezas envolvidas no processo de geração de energia elétrica, e estes resultados foram comparados com as medidas fornecidas pelas leituras dos instrumentos, enquanto a máquina no ambiente da microusina experimental, era submetida à situação de carga zero até a máxima. Com os resultados colhidos procuramos estabelecer uma relação entre a potência mecânica nominal de motores assíncronos com a potência ativa nominal deste tipo de máquina operando como gerador.
729

Uma contribuição ao estudo de filtros passivos sintonizados em sistemas elétricos industriais /

Bortoluzzi, Adilson Pacheco, 1970-, Carvalho, Ricardo José de Oliveira, Universidade Regional de Blumenau. Programa de Pós-Graduação em Engenharia Elétrica. January 2012 (has links) (PDF)
Orientador: Ricardo José de Oliveira Carvalho. / Dissertação (mestrado) - Universidade Regional de Blumenau, Centro de Ciências Tecnológicas, Programa de Pós-Graduação em Engenharia Elétrica.
730

Análise de eficiência energética em sistemas de produção por meio da utilização de ferramentas de manufatura digital/

Antoniol, R. L. January 2016 (has links)
Dissertação (Mestrado em Engenharia Mecânica) - Centro Universitário FEI, São Bernardo do Campo, 2016.

Page generated in 0.0689 seconds