• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 8
  • 8
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Digital optically coupled transient recorder

Olyabek, Zuhair January 1993 (has links)
No description available.
2

Electrical signaling, gas exchange and turgor pressure in ABA-deficient tomato (cv. Micro-Tom) under drought / Sinalização elétrica, trocas gasosas e pressão de turgor em plantas deficientes na produção de ABA (cv. Micro-Tom) sob seca

Macedo, Francynês da Conceição Oliveira 13 November 2015 (has links)
This document refers to research whose main objective was to investigate the relationship among hydraulic, chemical and electrical signals in poor tomato plants ABA production. The document is organized into three chapters: The first chapter presents a detailed extracellular measurement protocol of electrical signals in plants and how to associate these measurements to determine gas exchange using the Infrared gas analyzer (IRGA) and turgor pressure using the patch clamp pressure probe (ZIM-probe). The second chapter refers to recording of the action potential generated spontaneously and evoked by electrical stimulation in ABA-deficient tomato, mutant sitiens. The final chapter presents the results for turgor pressure, gas exchange and electrical signals measurements in mutants notabilis and sitiens in the re-irrigated after a period of drought. The possible role of electrical signals in the plant signalling under stress conditions is discussed. The main conclusions related to chapters 1, 2 and 3 were: Measurement of extracellular electrical signals can be performed with gas exchange and turgor pressure measurements using IRGA ZIM-probe equipment; Electrical signals generated spontaneously in sitiens mutants propagate with amplitude and speed higher than in wild plants. Mutant is less responsive to electrical stimulation showing higher excitation threshold and longer refractory period than wild plants; The mutant plants are more responsive electrically to re-irrigation after drought than wild plants. The electrical signals precede changes in gas exchange in all genotypes, post irrigation. The ZIM-probe was not efficient to evaluate the turgor pressure in mutant plants under stress conditions, but is a promising tool for studies involving hydraulic and electrical signalling in wild plants. / O presente documento refere-se a pesquisa cujo principal objetivo foi investigar a relação entre sinais hidráulicos, químicos e elétricos em plantas de tomate deficientes da produção de ABA. O documento foi organizado em três capítulos: O primeiro capítulo apresenta um detalhado protocolo de medição extracelular de sinais elétricos em plantas e como associar estas medições a determinação de trocas gasosas usando o Analisador de gás por infravermelho (IRGA) e pressão de turgor usando a sonda de pressão (ZIM-probe). O segundo capítulo refere-se ao registro de potenciais de ação gerados espontaneamente e evocados por estímulo elétrico em tomateiro deficiente na produção de ABA, mutante sitiens. O último capítulo apresenta os resultados referentes a medições de pressão de turgor, trocas gasosas e sinais elétricos nos mutantes notabilis e sitiens, deficientes na produção de ABA reirrigadas após um período de déficit hídrico. O possível papel dos sinais elétricos na sinalização em plantas em condições de estresse é discutido. As principais conclusões referentes aos capítulos 1, 2 e 3 foram, respectivamente: As plantas mutantes são mais responsivas eletricamente a re-irrigação, após déficit hídrico com que as plantas selvagens. Medições extracelulares de sinais elétricos podem ser realizadas com medidas de trocas gasosas e pressão de turgor utilizando os equipamentos IRGA e ZIM-probe; Sinais elétricos gerados espontaneamente nos mutantes sitiens se propagam com amplitude e velocidade maiores do que nas plantas selvagens. sitiens é menos responsivo a estímulo elétrico do que plantas selvagens apresentando maior limiar de excitação e período refratário; Os sinais elétricos precedem as alterações nas trocas gasosas pós irrigação em todos os genótipos estudados. A sonda ZIM-probe não se mostrou eficiente para avaliar a pressão de turgor em plantas mutantes sob condições de estresse, mas para as plantas selvagens é uma ferramenta promissora para estudos envolvendo sinalização hidráulica e elétrica.
3

Electrical signaling, gas exchange and turgor pressure in ABA-deficient tomato (cv. Micro-Tom) under drought / Sinalização elétrica, trocas gasosas e pressão de turgor em plantas deficientes na produção de ABA (cv. Micro-Tom) sob seca

Francynês da Conceição Oliveira Macedo 13 November 2015 (has links)
This document refers to research whose main objective was to investigate the relationship among hydraulic, chemical and electrical signals in poor tomato plants ABA production. The document is organized into three chapters: The first chapter presents a detailed extracellular measurement protocol of electrical signals in plants and how to associate these measurements to determine gas exchange using the Infrared gas analyzer (IRGA) and turgor pressure using the patch clamp pressure probe (ZIM-probe). The second chapter refers to recording of the action potential generated spontaneously and evoked by electrical stimulation in ABA-deficient tomato, mutant sitiens. The final chapter presents the results for turgor pressure, gas exchange and electrical signals measurements in mutants notabilis and sitiens in the re-irrigated after a period of drought. The possible role of electrical signals in the plant signalling under stress conditions is discussed. The main conclusions related to chapters 1, 2 and 3 were: Measurement of extracellular electrical signals can be performed with gas exchange and turgor pressure measurements using IRGA ZIM-probe equipment; Electrical signals generated spontaneously in sitiens mutants propagate with amplitude and speed higher than in wild plants. Mutant is less responsive to electrical stimulation showing higher excitation threshold and longer refractory period than wild plants; The mutant plants are more responsive electrically to re-irrigation after drought than wild plants. The electrical signals precede changes in gas exchange in all genotypes, post irrigation. The ZIM-probe was not efficient to evaluate the turgor pressure in mutant plants under stress conditions, but is a promising tool for studies involving hydraulic and electrical signalling in wild plants. / O presente documento refere-se a pesquisa cujo principal objetivo foi investigar a relação entre sinais hidráulicos, químicos e elétricos em plantas de tomate deficientes da produção de ABA. O documento foi organizado em três capítulos: O primeiro capítulo apresenta um detalhado protocolo de medição extracelular de sinais elétricos em plantas e como associar estas medições a determinação de trocas gasosas usando o Analisador de gás por infravermelho (IRGA) e pressão de turgor usando a sonda de pressão (ZIM-probe). O segundo capítulo refere-se ao registro de potenciais de ação gerados espontaneamente e evocados por estímulo elétrico em tomateiro deficiente na produção de ABA, mutante sitiens. O último capítulo apresenta os resultados referentes a medições de pressão de turgor, trocas gasosas e sinais elétricos nos mutantes notabilis e sitiens, deficientes na produção de ABA reirrigadas após um período de déficit hídrico. O possível papel dos sinais elétricos na sinalização em plantas em condições de estresse é discutido. As principais conclusões referentes aos capítulos 1, 2 e 3 foram, respectivamente: As plantas mutantes são mais responsivas eletricamente a re-irrigação, após déficit hídrico com que as plantas selvagens. Medições extracelulares de sinais elétricos podem ser realizadas com medidas de trocas gasosas e pressão de turgor utilizando os equipamentos IRGA e ZIM-probe; Sinais elétricos gerados espontaneamente nos mutantes sitiens se propagam com amplitude e velocidade maiores do que nas plantas selvagens. sitiens é menos responsivo a estímulo elétrico do que plantas selvagens apresentando maior limiar de excitação e período refratário; Os sinais elétricos precedem as alterações nas trocas gasosas pós irrigação em todos os genótipos estudados. A sonda ZIM-probe não se mostrou eficiente para avaliar a pressão de turgor em plantas mutantes sob condições de estresse, mas para as plantas selvagens é uma ferramenta promissora para estudos envolvendo sinalização hidráulica e elétrica.
4

Algoritmos evolutivos como estimadores de frequência e fase de sinais elétricos: métodos multiobjetivos e paralelização em FPGAs / Evolutionary algorithm as estimators of frequency and phase of electrical signal: multi objective methods and FPGA parallelization

Silva, Tiago Vieira da 19 September 2013 (has links)
Este trabalho propõe o desenvolvimento de Algoritmos Evolutivos (AEs) para estimação dos parâmetros que modelam sinais elétricos (frequência, fase e amplitude) em tempo-real. A abordagem proposta deve ser robusta a ruídos e harmônicos em sinais distorcidos, por exemplo devido à presença de faltas na rede elétrica. AEs mostram vantagens para lidar com tais tipos de sinais. Por outro lado, esses algoritmos quando implementados em software não possibilitam respostas em tempo-real para uso da estimação como relé de frequência ou Unidade de Medição Fasorial. O desenvolvimento em FPGA apresentado nesse trabalho torna possível paralelizar o cálculo da estimação em hardware, viabilizando AEs para análise de sinal elétrico em tempo real. Além disso, mostra-se que AEs multiobjetivos podem extrair informações não evidentes das três fases do sistema e estimar os parâmetros adequadamente mesmo em casos em que as estimativas por fase divirjam entre si. Em outras palavras, as duas principais contribuições computacionais são: a paralelização do AE em hardware por meio de seu desenvolvimento em um circuito de FPGA otimizado a nível de operações lógicas básicas e a modelagem multiobjetiva do problema possibilitando análises dos sinais de cada fase, tanto independentemente quanto de forma agregada. Resultados experimentais mostram superioridade do método proposto em relação ao estimador baseado em transformada de Fourier para determinação de frequência e fase / This work proposes the development of Evolutionary Algorithms (EAs) for the estimation of the basic parameters from electrical signals (frequency, phase and amplitude) in real time. The proposed approach must be robust to noise and harmonics in signals distorted, for example, due to the presence of faults in the electrical network. EAs show advantages for dealing with these types of signals. On the other hand, these algorithms when implemented in software cant produce real-time responses in order to use their estimations as frequency relay or Phasor Measurement Unit. The approach developed on FPGA proposed in this work parallelizes in hardware the process of estimation, enabling analyses of electrical signals in real time. Furthermore, it is shown that multi-objective EAs can extract non-evident information from the three phases of the system and properly estimate parameters even when the phase estimates diverge from each other. This research proposes: the parallelization of an EA in hardware through its design on FPGA circuit optimized at level of basic logic operations and the modeling of the problem enabling multi-objective analyses of the signals from each phase in both independent and aggregate ways. Experimental results show the superiority of the proposed method compared to an estimator based on Fourier transform for determining frequency and phase
5

Algoritmos evolutivos como estimadores de frequência e fase de sinais elétricos: métodos multiobjetivos e paralelização em FPGAs / Evolutionary algorithm as estimators of frequency and phase of electrical signal: multi objective methods and FPGA parallelization

Tiago Vieira da Silva 19 September 2013 (has links)
Este trabalho propõe o desenvolvimento de Algoritmos Evolutivos (AEs) para estimação dos parâmetros que modelam sinais elétricos (frequência, fase e amplitude) em tempo-real. A abordagem proposta deve ser robusta a ruídos e harmônicos em sinais distorcidos, por exemplo devido à presença de faltas na rede elétrica. AEs mostram vantagens para lidar com tais tipos de sinais. Por outro lado, esses algoritmos quando implementados em software não possibilitam respostas em tempo-real para uso da estimação como relé de frequência ou Unidade de Medição Fasorial. O desenvolvimento em FPGA apresentado nesse trabalho torna possível paralelizar o cálculo da estimação em hardware, viabilizando AEs para análise de sinal elétrico em tempo real. Além disso, mostra-se que AEs multiobjetivos podem extrair informações não evidentes das três fases do sistema e estimar os parâmetros adequadamente mesmo em casos em que as estimativas por fase divirjam entre si. Em outras palavras, as duas principais contribuições computacionais são: a paralelização do AE em hardware por meio de seu desenvolvimento em um circuito de FPGA otimizado a nível de operações lógicas básicas e a modelagem multiobjetiva do problema possibilitando análises dos sinais de cada fase, tanto independentemente quanto de forma agregada. Resultados experimentais mostram superioridade do método proposto em relação ao estimador baseado em transformada de Fourier para determinação de frequência e fase / This work proposes the development of Evolutionary Algorithms (EAs) for the estimation of the basic parameters from electrical signals (frequency, phase and amplitude) in real time. The proposed approach must be robust to noise and harmonics in signals distorted, for example, due to the presence of faults in the electrical network. EAs show advantages for dealing with these types of signals. On the other hand, these algorithms when implemented in software cant produce real-time responses in order to use their estimations as frequency relay or Phasor Measurement Unit. The approach developed on FPGA proposed in this work parallelizes in hardware the process of estimation, enabling analyses of electrical signals in real time. Furthermore, it is shown that multi-objective EAs can extract non-evident information from the three phases of the system and properly estimate parameters even when the phase estimates diverge from each other. This research proposes: the parallelization of an EA in hardware through its design on FPGA circuit optimized at level of basic logic operations and the modeling of the problem enabling multi-objective analyses of the signals from each phase in both independent and aggregate ways. Experimental results show the superiority of the proposed method compared to an estimator based on Fourier transform for determining frequency and phase
6

MR-Guided Assessment and Management of Ventricular Tachycardia

Oduneye, Samuel 13 January 2014 (has links)
This thesis describes the electrical and physiological characterization of cardiac tissue with myocardial infarction (MI) responsible for abnormal cardiac rhythms such as ventricular tachycardia (VT), using a newly-developed magnetic resonance imaging (MRI) electrophysiology system. In electrophysiology (EP), radiofrequency (RF) catheter ablation combined with cardioverter-defibrillator implantation is a first-line action to manage ventricular VT. Unfortunately, this therapy is known to have sub-optimal success rates in a large number of patients because of difficulties to accurately identifying the arrhythmic target regions. Currently, characterization of post-MI scars is performed by using catheters to measure electrical signals of the endocardial tissue (electroanatomical mapping), under x-ray fluoroscopy guidance. Prolonged radiation exposure to both the cardiologist and the patient have made the use of MRI extremely attractive; further, unlike x-ray imaging, MRI provides post-MI scars with direct visualization, characterization in three dimensions and the ability to visualize ablation lesions. Although recent research has focused on registration between pre-acquired MR images and electroanatomical maps, a potentially more useful approach is to use real-time MRI to directly locate and characterize potential arrhythmogenic regions during the EP procedure. A real-time MR-guided EP system was developed and validated to perform EP diagnostic procedures, such as mapping and pacing. In a series of animal studies, the system demonstrated the ability to use active catheter tracking and intra-procedural MR imaging to navigate to specific regions in the left ventricle and record intracardiac electrical signals. A study correlating myocardial fibrotic scar detected by multicontrast late enhancement (MCLE) MRI and electroanatomical voltage mapping demonstrated that MRI information (transmurality, tissue classification, and relaxation rate) can accurately predict areas of myocardial fibrosis identified with bipolar voltage mapping. Finally, MCLE-derived gray zone was shown to have a high correspondence to regions with a high proportion of abnormal intracardiac signals. The methods described in this thesis help advance the understanding of infarcted tissue responsible for ventricular tachycardia. Further studies are proposed to perform RF ablation lesions and correlate pre- and post-ablation tissue electrophysiological properties with MRI.
7

MR-Guided Assessment and Management of Ventricular Tachycardia

Oduneye, Samuel 13 January 2014 (has links)
This thesis describes the electrical and physiological characterization of cardiac tissue with myocardial infarction (MI) responsible for abnormal cardiac rhythms such as ventricular tachycardia (VT), using a newly-developed magnetic resonance imaging (MRI) electrophysiology system. In electrophysiology (EP), radiofrequency (RF) catheter ablation combined with cardioverter-defibrillator implantation is a first-line action to manage ventricular VT. Unfortunately, this therapy is known to have sub-optimal success rates in a large number of patients because of difficulties to accurately identifying the arrhythmic target regions. Currently, characterization of post-MI scars is performed by using catheters to measure electrical signals of the endocardial tissue (electroanatomical mapping), under x-ray fluoroscopy guidance. Prolonged radiation exposure to both the cardiologist and the patient have made the use of MRI extremely attractive; further, unlike x-ray imaging, MRI provides post-MI scars with direct visualization, characterization in three dimensions and the ability to visualize ablation lesions. Although recent research has focused on registration between pre-acquired MR images and electroanatomical maps, a potentially more useful approach is to use real-time MRI to directly locate and characterize potential arrhythmogenic regions during the EP procedure. A real-time MR-guided EP system was developed and validated to perform EP diagnostic procedures, such as mapping and pacing. In a series of animal studies, the system demonstrated the ability to use active catheter tracking and intra-procedural MR imaging to navigate to specific regions in the left ventricle and record intracardiac electrical signals. A study correlating myocardial fibrotic scar detected by multicontrast late enhancement (MCLE) MRI and electroanatomical voltage mapping demonstrated that MRI information (transmurality, tissue classification, and relaxation rate) can accurately predict areas of myocardial fibrosis identified with bipolar voltage mapping. Finally, MCLE-derived gray zone was shown to have a high correspondence to regions with a high proportion of abnormal intracardiac signals. The methods described in this thesis help advance the understanding of infarcted tissue responsible for ventricular tachycardia. Further studies are proposed to perform RF ablation lesions and correlate pre- and post-ablation tissue electrophysiological properties with MRI.
8

Tester vlakového zabezpečovače / Automatic train protections system tester

Marek, Michal January 2017 (has links)
The Master´s thesis describes continuous automatic train protection system and its functional properties, principally the transmission of special encoded signal between stationary part and rail vehicle. There is also summarized some important information about the gear rotational speed sensors and its communication with other onboard peripherals. Depends by analysed parameters of electrical signals, the general suggestion of portable electronic device is outlined. Portable electronic device or TESTER will be used to in phase of testing mobile part of automatic train protection system mounted onboard of rail vehicle. Tester will generate equivalent electrical signals to signals in system automatic train protection and the real system response will be possible to evaluate. The generator block allows to model real electrical signals in automatic train protection technology type LS or type EVM and signals rail vehicle odometry.

Page generated in 0.0797 seconds