• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4606
  • 50
  • 38
  • 38
  • 38
  • 35
  • 24
  • 14
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 4658
  • 3982
  • 2564
  • 2465
  • 1445
  • 1279
  • 729
  • 543
  • 528
  • 524
  • 492
  • 478
  • 415
  • 384
  • 382
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
231

Aplicação da metodologia de planejamento integrado de recursos na expansão da distribuição :

Soares, Cinara Ribeiro January 2000 (has links)
Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. / Made available in DSpace on 2012-10-17T11:04:05Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-25T19:03:59Z : No. of bitstreams: 1 152844.pdf: 5267056 bytes, checksum: c4bd355943840eb81bf04b87abaef414 (MD5) / A presente dissertação aborda os seguintes enfoques: a problemática contribuição do setor elétrico aos desgastes ambientais e os efeitos da reestruturação deste setor sobre a Conservação de Energia. Baseado nesta discussão e com o intento de atender as necessidades impostas por estas duas perspectivas, este trabalho sugere o Planejamento Integrado de Recursos - PIR como alternativa adequada, onde o setor elétrico e principalmente a concessionária procuram delinear suas estratégias considerando objetivos sociais, ambientais, econômicos e de qualidade. Com base num Estudo de Caso, em um sistema de distribuição, procurou-se avaliar os efeitos da inclusão de programas de Gerenciamento pelo Lado da Demanda - GLD no processo tradicional de planejamento da expansão dos sistemas elétricos, realizando assim uma análise detalhada de PIR. Os resultados indicaram que o GLD constitui-se numa boa oportunidade da concessionária postergar investimentos na expansão do sistema, concluindo-se que esta estratégia caracteriza-se como uma interessante alternativa a ser acrescida no planejamento dos sistemas elétricos.
232

Um modelo para a programação da operação de sistemas hidrotérmicos baseado em relaxação lagrangeana

Rodrigues, Rafael Nilson 24 October 2012 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2009 / Made available in DSpace on 2012-10-24T20:54:05Z (GMT). No. of bitstreams: 1 271856.pdf: 4759615 bytes, checksum: a55c7147f3f06f74758a645d8a1c486d (MD5) / A Programação da Operação do Sistema Elétrico pode ser formulada por um problema de otimização cujo objetivo é a minimização do custo de operação e atendendo a um conjunto de restrições associadas ao sistema e às unidades de produção. Em sistemas hidrotérmicos, a fim de se assegurar o uso eficiente dos recursos disponíveis e a obtenção de soluções viáveis, torna-se necessária usar uma modelagem detalhada tanto das fontes hidrelétricas como das termelétricas. Conseqüentemente, tem-se um problema de grande porte e não convexo, cuja solução não é trivial. Particularmente, neste projeto consideram se as não linearidades das funções de produção das fontes termelétricas e hidrelétricas, bem como todas as restrições relevantes para cada tipo de fonte, tais como restrições de rampa e zonas proibidas de operação, entre outras. Adicionalmente, modelam-se as restrições dos intercâmbios de transmissão e a função de custo futuro para as hidrelétricas. Como solução desse problema tem-se um programa de geração horário para um horizonte de dois dias. Dada a dificuldade de se resolver o problema em referência, propõe-se o uso da técnica de Relaxação Lagrangeana a qual tem sido usada com êxito em problemas semelhantes. Nesse contexto, decompõe-se o problema original nos subproblemas de atendimento à demanda, hidráulico, de alocação de unidades hidrelétricas e de alocação de unidades termelétricas. Uma vez que a solução dual é infactível, este trabalho utiliza a técnica do Lagrangeano Aumentado Inexato para realizar a Recuperação Primal, utilizando o mesmo esquema de decomposição proposto. Assim é possível obter uma solução viável para o problema da programação da operação eletroenergética. Os algoritmos implementados são testados com uma configuração do sistema baseado no caso brasileiro. Nos resultados obtidos, são analisados os esforços computacionais, inviabilidade da solução dual, perfis de geração hidrelétrica e termelétrica, recuperação primal e o uso da função de custo futuro. / The short-term hydrothermal scheduling of a power system can be formulated as anoptimization problem that aims to minimize the operating cost and meet a set of constraints associated with the system and the generating units. Particularly, in hydrothermal systems, in order to ensure the efficient use of the available resources, it is necessary to use a detailed modeling for hydro and thermal plants and, as a consequence, it is obtained a huge and nonconvex problem, whose solution is not trivial. In this work, we consider the nonlinearities associated with the production functions of hydro and thermal plants, as well as all the relevant constraints associated with each type of technology, such as ramping constraint for thermal plants and forbidden operating zones for hydro plants. Additionally, the transmission capacity between subsystems and the value of the water in the future for hydro plants are modeled. The solution for this problem is calculated for a two day horizon with hourly steps . Given the difficulty to solve the problem aforementioned the Lagrangian Relaxation technique is proposed, which has been successfully applied in similar problems. By this technique, the original problem is decomposed into smaller subproblems easier to solve. Given that the dual solution is unfeasible, this work makes use of the Inexact Aumented Lagrangian to perform the primal recovery in order to ensure a feasible solution. Based on these principles, a set of algorithms were developed and implemented resulting in a computational model that was tested for the Brazilian system. By means of this application, a detailed analysis with respect to the computational burden and solution quality is presented. The results allow us to conclude that the proposed model is useful to be applied in real life problems.
233

Influência dos canais de instrumentação na exatidão da medição fasorial sincronizada

Lira, Ricardo 25 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2010 / Made available in DSpace on 2012-10-25T10:54:04Z (GMT). No. of bitstreams: 1 277711.pdf: 3172490 bytes, checksum: 257ff5e0772fcf405a506bbf719191a6 (MD5) / Neste trabalho, investiga-se a influência exercida pelos Canais de Instrumentação (CIs) na exatidão da medição fasorial sincronizada. São abordados estudos relacionados aos aspectos de exatidão dos CIs, em regime permanente, e à modelagem de seus elementos: Transformadores de Potencial Capacitivos (TPCs); Transformadores de Corrente (TCs); e cabos de controle. Destaca-se o problema do erro na medição de corrente em condições de baixo carregamento de Linhas de Transmissão (LTs), bem como a influência da carga imposta ao secundário dos TIs Transformadores de Instrumentos) sobre a exatidão de medições fasoriais. Foi também investigada a aplicação de diferentes metodologias para o cálculo do fluxo de potência em LTs, bem como o cálculo de seus parâmetros. Esses estudos são complementados por meio da análise de sensibilidade destes cálculos frente a erros fasoriais. Por fim, são apresentadas análises de desempenho envolvendo o protótipo de SPMS MedFasee Eletrosul, visando à detecção e à compensação de erros fasoriais introduzidos pelos CIs envolvidos. Constata-se a possibilidade de ocorrência de erros significativos de módulo e ângulo nos fasores, dependendo do nível de carregamento da LT e das peculiaridades dos CIs. Tais características foram comprovadas por estudos de sensibilidade aplicados a casos reais. / This work investigates the influence of the Instrumentation Channels (ICs) in the synchronized phasor measurement accuracy. Studies are addressed to accuracy of ICs, in steady state, and modeling of its elements: Coupled Capacitive Voltage Transformers (CCVTs) Current Transformers (CTs), and control cables. The problem of error in current measurement under conditions of low loading of Transmission Lines (TL) is highlighted, as well as the importance of the burden on the accuracy of phasor measurements. The application of different methodologies for power flow calculation in TL and its parameters calculation are also investigated. Those studies are complemented by sensitivity analysis of these methodologies against phasor errors. Finally, a performance analysis involving the SPMS MedFasee Eletrosul prototype is presented, focusing on the detection and compensation of errors introduced by the phasor ICs involved. The presence of significant errors in the module and phasor angle is verified, depending on the loading level of the TL and the peculiarities of ICs. These characteristics are confirmed by sensitivity analysis applied to real cases.
234

Proteção adaptativa de alimentadores de distribuição de energia elétrica considerando geração distribuída

Bittencourt, Annelise Anderson January 2011 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2011 / Made available in DSpace on 2012-10-25T17:47:02Z (GMT). No. of bitstreams: 1 292120.pdf: 1661631 bytes, checksum: 8eb3e8c762965731e5865a74ca40366f (MD5) / A instalação de unidades de Geração Distribuída (GD) nas redes de distribuição de energia elétrica pode gerar vantagens e desvantagens para a operação dos sistemas de potência, dependendo de vários fatores técnicos que envolvem a conexão destas unidades. Falhas nos sistemas de proteção podem ocorrer quando não são efetuados estudos de revisão sobre a coordenação da proteção levando em conta a inserção da unidade de GD em um alimentador pré-existente. Este trabalho apresenta uma proposta para proteção adaptativa de alimentadores de distribuição de energia elétrica considerando geração distribuída, como forma de contornar as dificuldades de coordenação da proteção neste contexto. A implementação da proteção adaptativa visa tornar mais eficaz o sistema de proteção, independentemente da topologia do sistema. Através de simulações em um sistema teste, são demonstradas algumas das alterações que a inserção de unidades de GD causa nos sistemas de distribuição, principalmente no que diz respeito à proteção dos alimentadores, uma vez que o foco deste estudo é a influência da inserção da GD nos tempos de atuação da função proteção de sobrecorrente. Através da análise dos resultados das simulações, verificou-se a necessidade de aprimorar as estratégias de proteção tradicionalmente empregadas, especialmente nos ajustes da função de sobrecorrente do alimentador. A proteção adaptativa implementada neste trabalho tem como objetivo alterar automaticamente os grupos de ajustes de um relé digital em função das condições do sistema de distribuição. O relé digital do alimentador monitora as correntes demandadas e recebe a informação do estado do disjuntor de interconexão da geração distribuída. A proposta foi avaliada através de simulações (software ATPDraw) envolvendo um sistema teste de distribuição do IEEE de 34 nós e de sua implementação em relés digitais comerciais. Os resultados obtidos, descritos e discutidos neste trabalho, atestam a capacidade e a eficiência da proposta de proteção adaptativa de alimentadores de distribuição de energia elétrica. / The installation of distributed generation (DG) units in electrical energy distribution networks has advantages and disadvantages for the power system operation, depending on several technical factors that involve the connection of these units. In order to avoid failures of protection systems, the coordination of protection devices should be reviewed when DG units are installed in a pre-existing feeder. This work proposes the application of adaptive protection to electricity distribution feeders considering distributed generation.Through simulations on a test system, the alterations caused by DG units installed in distribution systems are demonstrated, especially with regard to the protection of feeders. The object of this work is to analyze the negative influence of the insertion of DG on the operation times of the overcurrent function and thus propose an adaptive approach to solve the problem of the increase in the operation times. The analysis of the simulation results demonstrates the necessity of improving the protection strategies traditionally employed in distribution feeders, especially when setting the overcurrent function. The implementation of adaptive protection system aims to make the protection more effective, regardless the system topology. The adaptive protection implemented in this work aims to automatically change the group of settings that is active in a digital relay according to the conditions of the distribution system. The digital relay which protects the feeder monitors the current flowing and receives information about the status of the breaker at the interconnection of distributed generation. The proposal was evaluated through simulations (software ATPDraw) involving the IEEE 34-node test system and through its implementation in commercial digital relays. The results described and discussed in this work validate the capacity and efficiency of the proposed adaptive protection of feeders in distribution systems.
235

Alocação ótima de chaves telecomandadas em redes de distribuição com multi-objetivo via algoritmos genéticos de Pareto

Tenfen, Daniel January 2011 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica. / Made available in DSpace on 2012-10-25T20:14:09Z (GMT). No. of bitstreams: 1 298799.pdf: 2711957 bytes, checksum: 66b025fe8150aa50f6953a4628210eea (MD5) / O presente trabalho tem como objetivo a elaboração de uma metodologia para a alocação ótima de chaves de manobras telecomandadas, em alimentadores do sistema de distribuição, com e sem geração distribuída, com múltiplos objetivos sendo avaliados, visando a melhoria dos índices de continuidade coletivos e dos consumidores especiais. Inicialmente é feita uma redução no número de nós dos alimentadores, sendo mantidas suas características, visando a melhoria do desempenho do cálculo dos índices de continuidade e o fluxo de carga. Os dados das taxas de falhas e tempos de reparos dos trechos dos alimentadores, utilizados para calcular os índices de continuidade, são adquiridos via histórico de falhas do sistema de distribuição em estudo. Através da construção de uma matriz de alcance, juntamente com os tempos de reparos, as taxas de falhas, o número de consumidores e a carga, é possível verificar a influência dos equipamentos de proteção e manobras dentro do alimentador, e por conseqüência nos índices de continuidade. Este procedimento é realizado por meio da matriz lógico estrutural. Para cada chave de interligação entre alimentadores (chaves com posição normalmente aberta) é verificado, no esquema de operação em anel aberto, quais nós podem ser socorridos pelo alimentador que faz o socorro, através da alocação de uma chave telecomandada normalmente fechada, não violando os limites de corrente e tensão estabelecidos. Estes são os chamados pontos candidatos à transferência de carga. Esta avaliação também é feita caso uma geração distribuída possa operar ilhada ou com a possibilidade de operar em paralelo com o alimentador de socorro. O método de fluxo de carga utilizado é o método de soma de potências modificado, utilizado também quando da existência de geração distribuída no sistema de distribuição. Por fim, busca-se a otimização das posições das chaves telecomandadas normalmente abertas via um algoritmo genético muti-objetivos de Pareto, objetivando a melhoria dos índices de continuidade coletivos e individuais dos consumidores especiais, sendo validado por busca heurística exploratória / The present dissertation aims to develop a methodology for optimal allocation of telecontrolled switches in the distribution system feeders, with or without distribution generation, with multiple objectives being assessed, in order to improve collective and special consumers continuity index. It begins with a reduction of number of nodes in the feeders, keeping their characteristics, to improve the calculation of the reliability indexes and load flow. The data of the failure rates and repair times of the branches of feeders, which are used to calculate the reliability index, are acquired through building historical data of failures of the distribution system in study. By making a range matrix, along with the repair times, failure rates, the number of consumers and the load, it is possible to verify the influence of protective and switching equipment within the feeder, on the indices of continuity with a logical structural matrix. For each tie between feeders (switch with normally open position) in the scheme of operation in open loop, is checked which nodes can be rescued by a rescuing feeder, by allocating a remotely controlled normally closed switch, without violating voltage and current limits. These points are the candidates for load transfer. This assessment can also be made if the distributed generation is to operate islanded or with the ability to operate in parallel with the interconnecting feeder. The load flow method used is a modified sum of powers, also used when distributed generation is present in distribution system. In order to solve the optimization of the positions of normally open telecontrolled switches, a Pareto multi-objective genetic algorithm is used, with the objective of improve reliability of a set of consumers and individual priority consumers, being validated by heuristic search exploration
236

Determinação do nível ótimo de contratação de energia elétrica para grandes consumidores baseado em técnicas de gerenciamento do risco

Bittencourt, Diego January 2011 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica / Made available in DSpace on 2012-10-26T00:26:02Z (GMT). No. of bitstreams: 1 301152.pdf: 709239 bytes, checksum: 9c0e3eebf91c489312e5aa1a838a23d0 (MD5) / Este trabalho apresenta uma metodologia para determinação do nível ótimo de contratação de energia elétrica, tendo como objetivo a minimização do valor esperado do risco ao mercado spot, para grandes consumidores. Para aplicação da metodologia, são avaliados três consumidores com diferentes perfis de consumo, e são criadas curvas empíricas de distribuição de probabilidade normal e log-normal com intuito de representar os dados utilizados de consumo mensal de energia elétrica e da média mensal do preço de liquidações de diferenças, respectivamente. Na continuidade, é utilizada a simulação Monte Carlo, na busca por estabelecer, aleatoriamente, cenários futuros de consumo e preço de energia elétrica. Posteriormente, são simulados possíveis cenários de contratação de energia elétrica, e a convolução destas curvas empíricas faz com que sejam obtidos os valores de exposição ao mercado spot. O risco à não contratação de energia elétrica, é quantificado por ferramentas de análise de decisão sob risco utilizadas na indústria financeira. Tendo em vista a redução do valor esperado do risco, são propostas a gestão integrada do risco e o uso da geração de energia elétrica com o óleo diesel. Neste trabalho, propõe-se um modelo computacional baseado na técnica de simulação Monte Carlo, que auxilie o tomador de decisões na definição do quanto de energia elétrica deve ser contratada. O modelo proposto é aplicado ao Setor Elétrico Brasileiro, com o intuito de demonstrar sua viabilidade prática e conceitual. / This work presents a methodology for determining the optimal level for purchasing electricity, with the purpose of minimizing the risk to the expected value of spot market, for large consumers. For application of the methodology are assessed three consumers with different consumption characteristic, and are created empirical probability distribution of normal and log-normal curves with the aim of representing the data used for monthly consumption of electricity and the monthly average settlement price differences, respectively. Continuing, it uses a Monte Carlo simulation, in seeking to establish, at random, future scenarios of consumption and price of electricity. Subsequently, possible scenarios are simulated of electricity hiring, and convolution of these empirical curves makes them obtained the values of exposure to the spot market. The risk of non-contracting electricity is quantified by analysis tool used for decision making under risk in the financial industry. In order to reduce the expected value of risk, are proposed integrated management of risk and use of electric power generation with diesel oil. In this works, we propose a computational model based on Monte Carlo simulation technique, which helps the decision maker in defining how much power should be hired. The proposed model is applied to the Brazilian Electricity Sector, in order to demonstrate its practical and conceptual feasibility.
237

Desenvolvimento de modelos de programação estocástica aplicados à programação mensal da operação energética

Gonçalves, Raphael Eduardo Chagas January 2011 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica / Made available in DSpace on 2012-10-26T01:17:59Z (GMT). No. of bitstreams: 1 299886.pdf: 3025664 bytes, checksum: bcaf35ce625460fd11b52a0069bc1727 (MD5) / O planejamento da operação energética de sistemas hidrotérmicos é usualmente divido em etapas as quais apresentam diferentes horizontes de estudo e priorizam distintos aspectos da modelagem física do problema. A Programação Mensal da Operação Energética - PMO, que corresponde a uma das etapas de estudo do problema do planejamento da operação no caso brasileiro sob a ótica do Operador Nacional do Sistema - ONS, apresenta importantes resultados e, assim, suas particularidades são o objeto de estudo deste trabalho. Em particular, os modelos matemáticos utilizados nessa etapa tem o intuito de definir as estratégias semanais de geração das usinas integrantes do sistema com o menor custo esperado de operação, considerando as incertezas associadas às vazões afluentes aos reservatórios do sistema. Solucionar problemas com essas características requer o uso de métodos avançados de Programação Estocástica - PE. Neste trabalho tem-se o objetivo de avaliar as políticas resultantes e o desempenho computacional de dois algoritmos de PE quando aplicados ao problema relacionado à etapa do PMO. Inicialmente, destaca-se o estudo de diferentes estratégias de decomposição do problema via o método Progressive Hedging - PH no sentido de prover benefícios ao desempenho computacional do mesmo, além da avaliação de técnicas de partida quente e alternativas associadas à atualização de parâmetros internos para acelerar a convergência do método. Em seguida, uma análise comparativa entre o método de PH e a Decomposição Aninhada - DA, método atualmente vigente no Brasil, é apresentada sob o ponto de vista computacional e também no que diz respeito às políticas resultantes de ambos. Para tanto, o Sistema Interligado Nacional - SIN é utilizado
238

Inversor multiníveis híbrido trifásico baseado em módulos meia-ponte

Batschauer, Alessandro Luiz January 2011 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica / Made available in DSpace on 2012-10-26T03:33:57Z (GMT). No. of bitstreams: 1 298390.pdf: 10373042 bytes, checksum: 8f4333c73671d8af9ef6af3a043c1398 (MD5) / O presente trabalho aborda o desenvolvimento e a implementação de novas estruturas de conversores multiníveis para inversores de tensão trifásico multiníveis. Estes inversores são híbridos, empregando duas topologias diferentes conectadas em cascata para sintetizar uma tensão de saída com maior quantidade de níveis de tensão e baixa distorção harmônica. A associação proposta é baseada na conexão série de um inversor de tensão trifásico com pares de células monofásicas de conversores meia-ponte. Os conversores meia-ponte são conectados aos pares no intuito de se obter uma tensão sem nível contínuo na saída. Obtêm-se assim conversores modulares e com capacidade de expansão. As etapas de operação, as equações que definem as correntes médias e eficazes nos semicondutores e uma análise teórica da tensão de saída são apresentadas em detalhe. Também é proposta uma estratégia de modulação com a comutação em baixa frequência do inversor trifásico. Esta estratégia permite a alteração da lógica de comutação dos interruptores de forma a manter o fluxo unidirecional de energia nos retificadores de entrada, possibilitando a redução de custos associados a estes. É realizado um estudo detalhado das perdas de condução e comutação nos interruptores, o dimensionamento dos capacitores de barramento e uma comparação do conversor proposto com conversores existentes na literatura. Apresenta-se ainda uma proposta de retificador multipulsos de entrada para realizar a conversão ca-cc, necessária à alimentação com fontes isoladas e garantir correntes drenadas de alta qualidade.O presente trabalho aborda o desenvolvimento e a implementação de novas estruturas de conversores multiníveis para inversores de tensão trifásico multiníveis. Estes inversores são híbridos, empregando duas topologias diferentes conectadas em cascata para sintetizar uma tensão de saída com maior quantidade de níveis de tensão e baixa distorção harmônica. A associação proposta é baseada na conexão série de um inversor de tensão trifásico com pares de células monofásicas de conversores meia-ponte. Os conversores meia-ponte são conectados aos pares no intuito de se obter uma tensão sem nível contínuo na saída. Obtêm-se assim conversores modulares e com capacidade de expansão. As etapas de operação, as equações que definem as correntes médias e eficazes nos semicondutores e uma análise teórica da tensão de saída são apresentadas em detalhe. Também é proposta uma estratégia de modulação com a comutação em baixa frequência do inversor trifásico. Esta estratégia permite a alteração da lógica de comutação dos interruptores de forma a manter o fluxo unidirecional de energia nos retificadores de entrada, possibilitando a redução de custos associados a estes. É realizado um estudo detalhado das perdas de condução e comutação nos interruptores, o dimensionamento dos capacitores de barramento e uma comparação do conversor proposto com conversores existentes na literatura. Apresenta-se ainda uma proposta de retificador multipulsos de entrada para realizar a conversão ca-cc, necessária à alimentação com fontes isoladas e garantir correntes drenadas de alta qualidade. / This work presents the proposal, analysis, development and implementation of novel three-phase voltage source multilevel inverter structures. The structures form hybrid inverters employing two different cascaded connected topologies used to synthesize a multilevel output voltage with low harmonic distortion. Specifically, the proposed converter is based on a series connection of a three-phase voltage source inverter with pairs of single-phase halfbridge converters. Thus, a modular converter structure is achieved and the topologies become easily expandable to a high number of levels. The half-bridge converters are connected in pairs to eliminate the dc level at the output voltage. The operation stages, the equations that describes the average and the RMS current values at the semiconductors and a theoretical analysis of the output voltage are presented in detail. An appropriated modulation strategy is also proposed in this work. The proposed modulation switches the three-phase voltage source inverter at the fundamental frequency, while the half-bridge converters are driven at high switching frequency. The modulation scheme features changes in the switching signals to achieve a unidirectional power flow in the input rectifiers. Detailed studies are done regarding conduction and switching losses, design of the retictifier#s dc-link capacitors and a comparison between the proposed converter and converters presented in the literature. A multipulse rectifier is also presented to feed the proposed inverter with low harmonics in the input current.
239

Alocação de chaves automatizadas em redes de distribuição utilizando múltiplos critérios

Aranha Neto, Edison Antonio Cardoso January 2006 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica. / Made available in DSpace on 2012-10-22T21:02:07Z (GMT). No. of bitstreams: 1 232412.pdf: 1228846 bytes, checksum: dfa041049da0f796d3114de699219c50 (MD5) / O presente trabalho tem como objetivo o desenvolvimento de uma metodologia para a alocação de chaves automatizadas em redes de distribuição, utilizando ferramentas de otimização multicritério para atender a diferentes políticas de desempenho. Devido à complexidade do problema, a metodologia foi divida em três partes, denominadas de módulos. O primeiro módulo a ser executado é o Modulo de Reconfiguração, cuja função principal é estabelecer os pontos candidatos à alocação de uma chave automatizada. A seguir, o Módulo de Confiabilidade calcula para estes pontos o impacto nos índices de confiabilidade causados pela alocação de uma chave. O terceiro e último módulo, o Módulo Multicritério, é responsável pelo cálculo da ordem de mérito (hierarquização) das posições candidatas a receberem uma chave, de acordo com as preferências do decisor. A metodologia para alocação de chaves automatizadas foi aplicada em um sistema teste composto por três alimentadores obtidos na literatura internacional e em um sistema composto por dois alimentadores baseados em dados de consumidores e cargas reais e também nas configurações e registros de falhas, manobras e manutenção de uma concessionária brasileira. Os resultados obtidos demonstram a viabilidade da metodologia desenvolvida e mostram os ganhos introduzidos ao sistema com a alocação de chaves automatizadas.
240

Máximo carregamento em sistemas de potência com restrições de reserva de geração

Fernandes, Carlos Eduardo Monteiro January 2006 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica. / Made available in DSpace on 2012-10-22T21:24:09Z (GMT). No. of bitstreams: 1 233950.pdf: 611140 bytes, checksum: eebc809d6cc879dc22bbf033f7c9d2cf (MD5) / A melhoria da qualidade do suprimento de energia depende da manutenção de uma margem de geração de potência que garanta a segurança da operação da rede de energia elétrica. O presente trabalho propõe a aplicação de um método de otimização estática para a determinação de soluções operativas no limite de carregamento, com restrições na margem de potência gerada. Mostra-se como o carregamento crítico, os recursos do controle de tensão e a disponibilidade de potência reativa são modificados em função da especificação de margens de potência. O problema de maximização do carregamento é formulado com a inclusão de duas restrições de desigualdade, relacionadas diretamente aos desvios de uma distribuição de potência pré-especificada. Na solução obtida através desta formulação, a demanda é maximizada e simultaneamente as margens de potência são ajustadas.

Page generated in 0.0731 seconds