• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 86
  • 7
  • 1
  • 1
  • Tagged with
  • 95
  • 45
  • 30
  • 23
  • 15
  • 12
  • 10
  • 10
  • 10
  • 9
  • 9
  • 9
  • 9
  • 9
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

A Contribution to Video Streaming Quality and Energy Efficiency in Optical and Ethernet Networks

Vargas Hernández, Tito Raúl 18 April 2023 (has links)
[ES] La distribución de contenidos multimedia, tanto a través de Internet como de redes gestionadas dedicadas exclusivamente a este fin, está teniendo una mayor cuota del tráfico total y crece cada día, especialmente el servicio de vídeo streaming. Por ello, ha surgido el interés de investigar para mantener y mejorar la Calidad de Servicio (QoS) en redes de acceso y backbone, y ofrecer Calidad de Experiencia (QoE) a los usuarios finales; mediante el ajuste de parámetros, configuraciones, protocolos y algoritmos a los requerimientos de la red en cuanto a la alta demanda de tráfico de vídeo. Lo anterior aprovechando al máximo los recursos de la red, tanto en el núcleo y las redes de acceso, como el ancho de banda y la capacidad total instalada, y al mismo tiempo, proponiendo alternativas de transporte eficientes para el tráfico de vídeo agregado sin incrementar los costos de los servicios; y alternativas para reducir los costos operativos y gastos de mantenimiento de manera eficiente, como por ejemplo la reducción del consumo de energía. En primer lugar, esta tesis aborda el estudio de propuestas de conmutación óptica en redes troncales y la distribución de contenidos multimedia, particularmente la propuesta de Red de Conmutación Óptica de Ráfagas (OBS) desde el punto de vista de la Ingeniería Telemática. Por lo tanto, se estudia la arquitectura, protocolos y algoritmos de estas redes para hacer aportes a la evaluación del tráfico de vídeo y alternativas para ofrecer QoS y QoE para el tráfico multimedia. En este sentido, este trabajo contribuye con propuestas para la evaluación de la calidad mediante simulación utilizando trazas de transmisiones de vídeo reales, y propuestas de algoritmos de scheduling y ensamblaje de ráfagas ópticas para ofrecer QoS y QoE al tráfico de vídeo en las redes OBS. En segundo lugar, se estudian los patrones de tráfico de vídeo a nivel de aplicación y de red para caracterizarlos y realizar estudios de eficiencia energética y ahorro de consumo energético en las tarjetas de red utilizadas por servidores de vídeo en streaming y clientes que implementan el estándar IEEE 802.3az Energy Efficient Ethernet (EEE), tanto en redes gestionadas, como IPTV que implementa transmisión de vídeo RTP, como en redes no gestionadas, como Internet, que implementa el estándar Dynamic Adaptive Streaming over HTTP (DASH) para servicios Over The Top (OTT). Para alcanzar este objetivo, se implementan testbeds y se llevan a cabo experimentos para concluir cómo el tráfico de vídeo podría beneficiarse de la eficiencia energética y lograr una reducción a gran escala en el consumo de energía si el estándar EEE se implementa a nivel mundial en las tarjetas Ethernet de los dispositivos involucrados en la distribución de vídeo. El tema integrador que se aborda en esta tesis es la distribución de vídeo digital. Por lo tanto, este trabajo también presenta un estudio sobre la codificación y adaptación de transmisión de vídeo en redes IP, presentando aspectos relacionados con la evaluación de la calidad de vídeo y la evaluación de la calidad de transmisión de la red. Por ello, se proponen e implementan metodologías y bancos de pruebas que involucran la programación y ejecución de simuladores, scripts, algoritmos, software y, en general, frameworks para realizar estudios de transmisiones de vídeo en redes de telecomunicaciones, cubriendo el amplio espectro de las Comunicaciones Multimedia. Este estudio podría ser de utilidad para emprender otros estudios necesarios ante la rápida evolución tanto de la demanda de servicios multimedia como de las propuestas de nuevas técnicas de distribución de contenidos. / [CAT] La distribució de continguts multimèdia, a través d'Internet i a través de xarxes gestionades dedicades exclusivament a aquesta finalitat, està tenint una part més gran del trànsit total i augmenta cada dia, especialment el servei de streaming de vídeo. Per tant, ha sorgit l'interés de la recerca per mantenir i millorar la Qualitat de Servei (QoS) en les xarxes d'accés i troncals, i per oferir Qualitat d'Experiència (QoE) als usuaris finals, ajustant paràmetres, configuracions, protocols i algoritmes als requeriments de la xarxa pel que fa a l'alta demanda de trànsit de vídeo. Aquest últim, aprofitant al màxim els recursos de xarxa al nucli i a les xarxes d'accés, com ara l'amplada de banda i la capacitat instal·lada total, i alhora, proposant alternatives de transport eficients per al trànsit agregat de vídeo sense augmentar els costos dels serveis i alternatives per reduir les despeses operatives i de manteniment d'una manera eficient, com ara reduir el consum d'energia. En primer lloc, aquesta tesi tracta l'estudi de les propostes de commutació òptica en xarxes troncals pel que fa a la distribució de continguts multimèdia, especialment l'estudi de la proposta de xarxes de commutació de ràfegues òptiques (OBS) des del punt de vista de l'Enginyeria Telemàtica. Per tant, s'estudia l'arquitectura, els protocols i els algoritmes d'aquestes xarxes per fer contribucions a l'avaluació del trànsit de vídeo i alternatives per oferir QoS i QoE per al trànsit multimèdia. En aquest sentit, aquest treball contribueix amb propostes per a l'avaluació de la qualitat mitjançant la simulació utilitzant traces de transmissions de vídeo reals, i propostes d'algoritmes de programació i muntatge de ràfegues òptiques per oferir QoS i QoE al trànsit de vídeo a les xarxes OBS. En segon lloc, s'estudien els patrons de trànsit de vídeo a nivell d'aplicació i xarxa per caracteritzar-los i realitzar estudis sobre eficiència energètica i estalvi energètic en les targetes de xarxa utilitzades pels servidors i clients de vídeo en streaming que implementen l'IEEE 802.3az Energy Efficient Ethernet (EEE) estàndard, tant en xarxes gestionades com IPTV, que implementa la transmissió de vídeo RTP, com en xarxes no gestionades com Internet, que implementa l'estàndard Dynamic Adaptive Streaming sobre HTTP (DASH) per als serveis Over The Top (OTT). Per assolir aquest objectiu, s'implementen bancs de proves i es realitzen experiments per concloure com el trànsit de vídeo podria beneficiar l'eficiència energètica i aconseguir una reducció a gran escala del consum d'energia si s'implementa l'estàndard EEE a les targetes Ethernet dels dispositius implicats en la distribución de vídeo. El tema integrador que s'aborda en aquesta tesi és la distribució de vídeo digital, per tant, aquest treball també presenta un estudi sobre la codificació i adaptació de la transmissió de vídeo a les xarxes IP, presentant aspectes relacionats amb l'avaluació de la qualitat del vídeo i l'avaluació de la qualitat de la transmissió de la xarxa. Per això, es proposen i s'implementen metodologies i bancs de proves que impliquen la programació i execució de simuladors, scripts, algoritmes, programari i, en general, frameworks per a la realització d'estudis de transmissions de vídeo en xarxes de telecomunicacions, abastant l'ampli espectre de les Comunicacions Multimèdia. Aquest estudi podria ser útil per emprendre altres estudis necessaris en la ràpida evolució tant de la demanda de serveis multimèdia com de les noves propostes de tècniques de distribució de continguts. / [EN] Multimedia content distribution, both over the Internet and over managed networks dedicated exclusively for this purpose, is having a greater share of total traffic and it is raising every day, especially the video streaming service. Therefore, research interest has arisen to maintain and improve the Quality of Service (QoS) in access and backbone networks, and to offer Quality of Experience (QoE) to end users, by adjusting parameters, configurations, protocols and algorithms to the network requirements regarding the video traffic high demand. The latter is carried out taking full advantage of the network resources at core and access networks such as bandwidth and total installed capacity, and at the same time, proposing efficient transportation alternatives for the aggregated video traffic without increasing services costs and alternatives to reduce operational and maintenance expenditures in an efficient manner, such as reducing the energy consumption. In the first place, this thesis deals with the study of optical switching proposals in backbone networks regarding multimedia content distribution, particularly studying the Optical Bursts Switching (OBS) Networks proposal from the Telematics Engineering point of view. Therefore, architecture, protocols and algorithms of these networks are studied to make contributions to the video traffic evaluation and alternatives to offer QoS and QoE for multimedia traffic. In this sense, this work contributes with proposals for the evaluation of quality through simulation using traces of real video transmissions, and optical burst assembly and scheduling algorithms proposals to offer QoS and QoE to video traffic in the OBS networks. Secondly, video traffic patterns at the application and network level are studied to characterize them and carry out studies on energy efficiency and energy consumption savings in the network cards used by streaming video servers and clients that implement the IEEE 802.3az Energy Efficient Ethernet (EEE) standard, both in managed networks, such as IPTV that implements RTP video streaming, and unmanaged networks, such as Internet which implements Dynamic Adaptive Streaming over HTTP (DASH) standard for Over The Top (OTT) services. To reach this goal, testbeds are implemented, and experiments are carried out to conclude how video traffic could benefit from the energy efficiency and achieve a large-scale reduction in energy consumption if the EEE standard is implemented word wide in the Ethernet cards of devices involved in video distribution. The integrating subject that is addressed in this thesis is the distribution of digital video. Therefore, this work also presents a study on the IP networks video transmission encoding and adaptation, presenting aspects regard the video quality evaluation and the network transmission quality assessment. Therefore, methodologies and testbeds are proposed and implemented that involves programming and execution of simulators, scripts, algorithms, software and, in general, frameworks to carry out studies for video transmissions in telecommunications networks, covering the broad spectrum of Multimedia Communications. This study could be useful to undertake other necessary studies in the rapid evolution of both, multimedia services demand and new content distribution techniques proposals. / Vargas Hernández, TR. (2023). A Contribution to Video Streaming Quality and Energy Efficiency in Optical and Ethernet Networks [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/192760
92

Implementation of New Algorithms for an Accurate Gamma-Ray Impact Determination in Scintillation Monolithic Blocks for PET Applications

Freire López-Fando, Marta 07 September 2023 (has links)
Tesis por compendio / [ES] La Tomografía por Emisión de Positrones (PET) es una potente técnica de imagen que proporciona mediante el uso de radiofármacos específicos medidas cuantitativas de los procesos biológicos y fisiológicos que tienen lugar en el organismo a nivel molecular. Las imágenes PET proporcionan información funcional que permite el diagnóstico precoz y el seguimiento personalizado del tratamiento terapéutico. La PET tiene aplicaciones en diversas áreas clínicas y de investigación, como la oncología, la neurología o la cardiología, entre otras. Los esfuerzos por mejorar las prestaciones de los sistemas PET se centran en aumentar su sensibilidad y calidad de imagen, lo que permite una evaluación clínica más precisa. En las imágenes PET, se inyecta al paciente un radiotrazador marcado con un radionúclido emisor de positrones que se distribuye por todo el cuerpo. Durante la desintegración radiactiva del trazador, el isótopo emite un positrón que se aniquila con un electrón del tejido circundante, generando dos rayos gamma de 511 keV emitidos a aproximadamente 180º. La técnica PET se basa por tanto en la detección simultánea de estos dos rayos gamma, denominados fotones de aniquilación, empleando habitualmente un anillo de detectores alrededor del paciente. Mejorando el diseño y el rendimiento de estos detectores, se mejoran las capacidades diagnósticas que ofrece la imagen PET. Para aumentar el rendimiento, se ha sugerido utilizar detectores basados en diseños de cristales monolíticos, debido a sus ventajas en comparación con los detectores pixelados. Sin embargo, su implementación en escáneres comerciales requiere superar algunos retos relacionados principalmente con los métodos de posicionamiento y los procedimientos de calibración necesarios para proporcionar las coordenadas de impacto del fotón de aniquilación y el tiempo de llegada de los fotones. Esta tesis doctoral se centra en el desarrollo y validación experimental de metodologías para la determinación precisa de esta información en detectores monolíticos, haciendo hincapié en su aplicación práctica también a sistemas PET completos. Durante esta tesis se han estudiado los principios fundamentales de los detectores PET monolíticos para comprender su comportamiento y limitaciones. En primer lugar, se han considerado las configuraciones típicas de detectores monolíticos basadas en bloques de centelleo continuo acoplados a matrices de SiPMs planas; además, también se han evaluado y validado otros enfoques novedosos. Se han desarrollado dos metodologías principales, una basada en técnicas analíticas y otra en algoritmos de Aprendizaje Profundo, para el posicionamiento 3D de la interacción del fotón con el fin de aumentar el rendimiento global del detector. Finalmente, los métodos propuestos han sido validados a nivel de detector, pero también en diferentes escáneres PET desarrollados en i3M. La presente tesis se basa en un compendio de los artículos más relevantes publicados en revistas revisadas por pares por el doctorando y está organizada de la siguiente manera. El Capítulo I presenta una introducción al trabajo de la tesis, compuesto por tres secciones: Imagen Médica, principios de la Tomografía por Emisión de Positrones y, Estimación de posición y calibración en detectores monolíticos. El Capítulo II contiene los objetivos específicos de esta tesis y las principales contribuciones del candidato a este campo. Este capítulo también incluye algunas metodologías y resultados recientes que aún no han sido publicados. El Capítulo III colecciona una copia de los cuatro artículos publicados seleccionados para el compendio, en los que el candidato es el primer autor [1]-[4]. En el Capítulo IV se discuten los principales resultados y conclusiones alcanzados durante la tesis. Por último, el Capítulo V presenta la discusión de esta tesis, resumiendo las principales contribuciones y destacando los logros científicos. / [CAT] La Tomografia per Emissió de Positrons (PET) és una potent tècnica d'imatge que proporciona mitjançant l'ús de radiofàrmacs específics mesures quantitatives dels processos biològics i fisiològics que tenen lloc en l'organisme a nivell molecular. Les imatges PET proporcionen informació funcional que permet el diagnòstic precoç i el seguiment personalitzat del tractament terapèutic. La PET té aplicacions en diverses àrees cliniques y d¿investigació, com l'oncologia, la neurologia o la cardiologia, entre altres. Els esforços per millorar les prestacions dels sistemes PET se centren en millorar la seua sensibilitat i qualitat d'imatge, la qual cosa permet una avaluació clínica més precisa més precís. En les imatges PET, s'injecta al pacient un radiotraçador marcat amb un radionúclid emissor de positrons que es distribueix per tot el cos. Durant la desintegració radioactiva del traçador, l'isòtop emet un positró que s'aniquila amb un electró del teixit circumdant, generant dos raigs gamma de 511 keV emesos a aproximadament 180º. La tècnica PET es basa per tant en la detecció simultània d'aquests dos raigs gamma, denominats fotons d'anihilació, emprant habitualment un anell de detectors al voltant del pacient. Millorant el disseny i el rendiment d'aquests detectors, es millora les capacitats diagnòstiques que ofereix la imatge PET. Per a augmentar el rendiment, s'ha suggerit utilitzar detectors basats en dissenys de cristalls monolítics, a causa dels seus avantatges en comparació amb els detectors pixelats. No obstant això, la seua implementació en escàners comercials requereix superar alguns reptes relacionats principalment amb els mètodes de posicionament i els procediments de calibració necessaris per a proporcionar les coordenades d'impacte del fotó d'anihilació i el temps d'arribada dels fotons. Aquesta tesi doctoral se centra en el desenvolupament i validació experimental de metodologies per a la determinació precisa d'aquesta informació en detectors monolítics, posant l'accent en la seua aplicació pràctica també a sistemes PET complets. Durant aquesta tesi s'han estudiat els principis fonamentals dels detectors PET monolítics per a comprendre el seu comportament i limitacions. En primer lloc, s'han considerat les configuracions típiques de detectors monolítics basats en blocs de centellege continu acoblats a matrius SiPM planes; a més, també s'han evaluat i validat altres enfocaments nous. S'han desenvolupat dues metodologies principals, una basada en tècniques analítiques i una altra en algoritmes d'Aprenentatge Profund, pel posicionament 3D de la interacció del fotó amb la finalitat d'augmentar el rendiment global del detector. Finalment, els mètodes proposats han sigut validats a nivell de detector però també en diferents escàners PET desenvolupats en i3M. La present tesi es basa en un compendi dels articles més rellevants publicats en revistes revisades per parells pel doctorand i està organitzada de la següent manera. El Capítol I presenta una introducció al treball de tesi, compost per tres seccions: Imatge Mèdica, principis de la Tomografia per Emissió de Positrons i, Estimació de posició i calibració en detectors monolítics. El Capítol II conté els objectius específics d'aquesta tesi i les principals contribucions del candidat a aquest camp. Aquest capítol també inclou algunes metodologies i resultats recents que encara no han sigut publicats. El Capítol III col·lecciona una còpia dels quatre articles publicats seleccionats pel compendi, en els quals el candidat és el primer autor [1]-[4]. En el Capítol IV es discuteixen els principals resultats i conclusions aconseguits durant la tesi. Finalment, el Capítol V presenta la discussió d'aquesta tesi, resumint les principals contribucions i destacant els assoliments científics. / [EN] Positron Emission Tomography (PET) is a powerful imaging technique that provides quantitative measurements of biological and physiological processes occurring within the body at the molecular level by using specific radiopharmaceuticals. PET imaging returns functional information that allows for early diagnosis and personalized therapy treatment follow up. It has applications in several research and clinical areas, such as oncology, neurology or cardiology, among others. Efforts to improve PET systems performance are focused on increasing their sensitivity and image quality, allowing for more accurate clinical assessments. In PET imaging, a radiotracer labeled with a positron-emitting radionuclide is injected to the patient and consequently, distributed throughout the body. During the radiotracer decay, the isotope emits a positron that annihilates with an electron of the surrounding tissues, generating two 511 keV gamma-rays emitted at approximately 180º. The PET technique is based therefore on the simultaneous detection of these two gamma-rays, called annihilation photons, by usually employing a ring of detectors around the patient. Improving the design and performance of these detectors, increases the diagnostic capabilities of PET imaging. To boost PET performance, it has been suggested to use detectors based on monolithic crystals designs, due to their advantages compared to pixelated detectors. However, their implementation in commercial scanners requires overcoming some challenges mostly related to photon impact positioning methods and calibration procedures to provide the impact coordinates and time of arrival of the annihilation photons. This PhD thesis focuses on the development and experimental validation of methodologies for an accurate determination of this information in monolithic detectors, emphasizing in their practical application to full PET systems. During this thesis, the main principles of monolithic-based PET detectors have been studied to understand their behavior and limitations. Typical monolithic detector configurations based on continuous scintillation blocks coupled to flat SiPM arrays have been first considered; additionally, other novel approaches have been also validated. Two main methodologies for 3D photon interaction positioning, one based on analytical methods and another based on Deep Learning algorithms, have been developed to increase the overall detector performance. The proposed methods have been validated at the detector level but also in different PET scanners developed by our group. The present thesis is based on a compendium of the most relevant papers published in peer-reviewed journals by the PhD candidate and is organized as follows. Chapter I presents an introduction to the thesis work, composed by three sections: Medical Imaging, principles of Positron Emission Tomography and, Position estimation and calibration in monolithic-based detectors. Chapter II contains the specific objectives of this thesis and the main contributions of the candidate to the field. This chapter also includes some recent methodologies and results that have not yet been published. Chapter III collects an author copy of the four published articles selected for the compendium, in which the candidate is the first author [1]-[4]. In Chapter IV the main results and conclusion achieved during the thesis are discussed. Finally, Chapter V presents the discussion of this thesis, summarizing the main contributions and highlighting the scientific achievements. / Freire López-Fando, M. (2023). Implementation of New Algorithms for an Accurate Gamma-Ray Impact Determination in Scintillation Monolithic Blocks for PET Applications [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/196084 / Compendio
93

Characterization of Dedicated PET Equipment with Non-Conventional Geometry

Cañizares Ledo, Gabriel 28 July 2022 (has links)
[ES] Desde su creación en la década de 1950, las imágenes tomográficas han resultado muy valiosas en el ámbito médico ayudando tanto en el diagnóstico como en el tratamiento de múltiples enfermedades. Dentro de la imagen molecular, los escáneres PET (Tomografía por Emisión de Positrones) generan información detallada de la interacción de los radio-trazadores con el tejido de estudio, pudiendo combinar dicha información con imagen anatómica de escáneres TC (Tomografía Computarizada) o RM (Resonancia Magnética). Con el fin de aumentar las prestaciones de estos equipos, como la sensibilidad y la resolución espacial, los PET de cuerpo completo recientemente aumentan su cobertura axial. Sin embargo, el precio de estos dispositivos se multiplica, dificultando su compra en muchos hospitales y centros de investigación. Como alternativa, los escáneres PET específicos de órganos manejan un menor número de detectores haciéndolos más económicos. El objetivo de este tipo de escáneres es mejorar el rendimiento de los dispositivos acercando los detectores al paciente lo máximo posible, optimizando su diseño para un órgano en específico. Otra ventaja es la posible portabilidad de los aparatos. En esta tesis introducimos dos posibles diseños de PET específicos orientados a distintos órganos y con diferente tecnología y geometría y además un escáner preclínico con una geometría novedosa. El primer escáner fue construido de un proyecto nacional llamado PROSPET, fue diseñado y optimizado para hacer imagen de la próstata, debido a la conocida elevada tasa de cáncer de próstata en hombres. El 17% de la población masculina sufrirá cáncer de próstata. El detector escogido para este diseño está compuesto por cristales centelladores monolíticos acoplados a una matriz de fotomultiplicadores de silicio. Inicialmente se pensó en crear un escáner compuesto por dos palas. Sin embargo, los resultados con pacientes no fueron satisfactorios debido a la falta de información angular y la ausencia de información temporal precisa en los detectores. Por tanto, se construyó una configuración de anillo con un diámetro reducido en comparación con escáneres de cuerpo completo. Se apreció un aumento en la sensibilidad y la resolución espacial, así como una buena calidad de imagen utilizando fantomas. El segundo escáner, llamado proyecto CardioPET, está orientado a visualizar el corazón cuando el paciente está sometido a condiciones de estrés farmacológico. Para este dispositivo se utilizó el diseño de dos palas, pero usando cristales pixelados, mejorando la resolución temporal, permitiendo implantar algoritmos de tiempo de vuelo. Se han montado y testeado dos palas tanto con simulaciones como experimentalmente con buenas prestaciones. Además, se procedió a registrar el movimiento de las fuentes de radiación con el fin de aplicar correcciones de movimiento con la ayuda de una cámara externa y unos marcadores ARUCO. Los algoritmos de corrección de movimiento fueron testeados, demostrando un buen funcionamiento. El último dispositivo fue diseñado para optimizar la configuración PET de anillo lo máximo posible. Para ello, se eliminaron los espaciados entre detectores en un escáner pequeño de animales, creando un único detector centellador de forma cilíndrica. Con esto se busca aumentar la sensibilidad, pues ya no se pierden interacciones en los huecos, y también la resolución espacial. Dos prototipos fueron testeados con simulaciones, y validados experimentalmente. El primero con caras de salida planas y el segundo totalmente cilíndrico. En ambos diseños se observaron efectos debidos a la curvatura del detector que necesariamente han de ser compensados con una calibración. / [CA] Des de la seua creació en la dècada de 1950, les imatges tomogràfiques hi han resultat molt valuoses en àmbit mèdic ajudant tant en el diagnòstic com en el tractament de moltes malalties. Dins de la imatge molecular, els escàners PET (Tomografia per Emissió de Positrons) generen informació detallada de la interacció dels traçadors amb el teixit del pacient, podent combinar aquesta informació amb imatge anatòmica d'escàners TC (Tomografia Axial Automatitzada) o RM (Ressonancia Magnètica). Amb el fi d'augmentar les prestacions d’aquests equips, els PET de cos complet augmenten la seua cobertura axial, multiplicant el preu dels dispositius i dificultant la seua compra en hospitals i centres d’investigació. Com a alternativa, els escàners PET específics d'òrgans utilitzen un menor nombre de detectors resultant així un preu més econòmic. Un altre avantatge és la possible portabilitat dels aparells. En aquesta tesi abordem tres possibles dissenys de PET específics orientats a diferents òrgans i amb diferent tecnologia i geometria. El primer de tots, un projecte nacional denominat PROSPET, ha sigut dissenyat i optimitzat per a fer imatge de la pròstata, ja que és molt coneguda l'elevada taxa de càncer de pròstata en homes. El 17% de población masculina patirà càncer de pròstata. El detector escollit per a aquest disseny està format per cristals centellejadors monolítics acoblats a una matriu de fotomultiplicadors de silici. De primeres es va pensar a crear un escàner compost per dues pales, ja que permetria disposar els detectors molt a prop del pacient. El resultat no va ser molt satisfactori a causa de la falta d'informació angular i l'absència d'informació temporal precisa. Per tant, l'última iteració va consistir en una configuració d'anell amb un diàmetre reduït en comparació amb els escàners de cos complet. Es va observar una millora en la sensibilitat i la resolució espacial, així com una qualitat d'imatge acceptable. El segon dispositiu va ser dissenyat per a optimitzar la configuració d'anell el màxim possible. Per això es van llevar els espaiats entre detectors, creant un únic detector de forma cilíndrica. Amb aquest disseny es busca augmentar la sensibilitat, ja que no es perden interaccions en els espaiats, i també la resolució espacial. Dos prototips van ser testejats amb simulacions i validats experimentalment. El primer amb cares d'eixida planars i el segon totalment cilíndric. En els dos dissenys es va observar efectes deguts a la curvatura del detector que necessàriament ha de ser compensat amb una calibració. L’últim escàner, denominat projecte CardioPET, està orientat a visualitzar el cor durant el pacient quan és sotmés a condicions d'estrés farmacologic. escàner, denominat projecte CardioPET, està orientat a visualitzar el cor durant el pacient quan és sotmés a condicions d'estrés. Es va recuperar el disseny de les pales per aquest dispositiu, però utilitzant cristals pixelats, millorant la resolució temporal. Dues pales van ser muntades i testejades tant amb simulacions com experimentalment amb bones prestacions. A més, es va registrar el moviment de les fonts de radiació amb la fi d'aplicar correcció de moviment amb l'ajuda d'una càmera externa i uns marcadors ARUCO. Els algoritmes de correcció de moviment també van ser testejats, demostrant un bon funcionament. L'últim dispositiu va ser dissenyat per a optimitzar la configuració d'anell el màxim possible. Per això es van llevar els espaiats entre detectors, creant un únic detector de forma cilíndrica. Amb aquest disseny es busca augmentar la sensibilitat, ja que no es perden interaccions en els espaiats, i també la resolució espacial. Dos prototips van ser testejats amb simulacions i validats experimentalment. El primer amb cares d'eixida planars i el segon totalment cilíndric. En els dos dissenys es va observar efectes deguts a la curvatura del detector que necessàriament ha de ser compensat amb una calibració. / [EN] Since their introduction in the 1950-decade, tomographic images have become very valuable in the medical field helping both in diagnostics and in a variety of illnesses treatment. In the molecular imaging field, Positron Emission Tomography (PET) provides accurate information of the radio-tracers interactions with the patient tissue. Moreover, it is possible to combine this information with anatomical images provided by CT (Computed Tomography) or MR (Magnetic Resonance) scanners. With the aim to improve PET systems performance, such as the spatial resolution and the sensitivity, whole body (WB) PET scanners with large axial coverage are recently proposed. However, the system cost increases and, thus, makes difficult their installation in many hospitals or research centers. Organ-dedicated PET scanners, as an alternative to such large systems, use a lower number of detectors, so their price is considerably more economical. The goal of this kind of systems is to boost PET performance by placing the detectors as close as possible to the patient, optimizing the design for a specific organ instead of a large volume. Other advantage of these scanners is their portability. In this thesis we have worked in the design and validation of two organ-dedicated PET scanners with different geometries and technologies, as well as in a novel pre-clinical PET. The first scanner was the result from a national project called PROSPET. A PET system was designed and optimized to image the prostate area. Notice there is a high incidence rate of prostate cancer in the male population. 17% of male population will suffer prostate cancer. For this scanner, the detector modules were composed by a monolithic LYSO scintillation block coupled to a photosensor array based on silicon photomultipliers (SiPM). The first design configuration was made by two panels. However, patient results were not satisfactory due to the lack of angular information and the poor detector time resolution. Therefore, it was rebuilt in a ring configuration with a reduced diameter in comparison with WB-PET scanners. A high sensitivity and spatial resolution were found, as well as a good image quality using phantoms. The second PET scanner, called CardioPET, also arose from a national grant, and it was implemented to visualize the heart area when the patient is under stress condition. The two panels geometry was also implemented for this system, but using pixelated crystals, therefore improving the detector time resolution and allowing to use time of flight (TOF) reconstruction algorithms. Two panels were mounted and tested with both simulation and experimental data with good results. Furthermore, the patient motion was registered applying movement correction techniques with the help of an external optical camera device and ARUCO markers. These algorithms were tested showing a good performance. The last device that we worked within this PhD thesis was designed to optimize the classical ring PET configuration as much as possible. To do so, the gaps between the detector modules in a small animal PET were eliminated by building a single detector with a cylindrical scintillator shape. The goal is to improve the sensitivity, given that there are no event losses in the gaps and to also boost the spatial resolution since there are not edges. Two prototypes were tested with simulations, and experimentally validated as well. The first of them was built with planar outer faces whereas the second was fully cylindrical. In both designs some effects originated from the detector curvature were observed and successfully corrected during the calibration. / This thesis was supported by a FPI grant under 2017-08582 reference in the PhD program: “Programa de Doctorado en Tecnologías para la Salud y el Bienestar” belonging to the Polytechnic University of Valencia. The grant was supported by the “Consejo Superior de Investigaciones Científicas” together with the “Agencia Estatal de Investigación” and the “Fondo Social Europeo”. / Cañizares Ledo, G. (2022). Characterization of Dedicated PET Equipment with Non-Conventional Geometry [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/184977 / TESIS
94

Caracterización multimodal de filtros de red y equipos electrónicos

Pérez Jiménez, Antonio 18 July 2008 (has links)
Un dels problemes més importants en la Compatibilitat Electromagnètica és el control de les interferències emeses i/o rebudes per un equip electrònic a través dels seus terminals d'alimentació monofàsica. Aquestes interferències es classifiquen en mode comú i mode diferencial. La manera més usual de mitigar-les és mitjançant la utilització de filtres de xarxa. Els mètodes actuals de disseny de filtres de xarxa tracten la mitigació d'aquest tipus d'interferències per separat: no tenen en compte que ambdós tipus de senyals (mode comú i diferencial) interaccionen entre sí i es transfereixen energia en qualsevol tipus d'asimetria originada pels equips electrònics o pels mateixos filtres. Aquest fet produeix freqüentment situacions inesperades: inefectivitat dels filtres de xarxa, aparició d'interferències en mode comú o diferencial inexplicables per la topologia dels circuits, selectivitat en freqüència del filtratge de les interferències, processos de radiació, etc. Aquest tipus de situacions poden ser analitzades i corregides a partir d'un anàlisi multimodal, que tingui en compte simultàniament el mode comú i el diferencial, i la seva interacció. El treball exposat aquí pretén:- Desenvolupar sistemes de mesura multimodal per a equips electrònics i filtres de xarxa. Aquests sistemes han de tenir en compte tant el mode comú, com el diferencial, com la seva interacció, i han de millorar les prestacions dels sistemes de mesura normatius actuals.- Trobar models equivalents des d'un punt de vista multimodal (tenint en compte simultàniament el mode comú, el diferencial i la seva interacció) tant d'equips electrònics com de filtres de xarxa.- Desenvolupar una metodologia de predicció de les interferències conduïdes que l'equip electrònic subministra a la xarxa elèctrica a través del filtre de xarxa al qual es troba connectat a partir dels models multimodals equivalents proposats per a ambdós dispositius.PARAULES CLAU: Compatibilitat electromagnètica, filtre de xarxa, equip electrònic, circuit equivalent, emissió conduïda, mode comú, mode diferencial, impedància d'entrada, paràmetres S. / Uno de los problemas más importantes en Compatibilidad Electromagnética es el control de las interferencias emitidas y/o recibidas por un equipo electrónico a través de sus terminales de alimentación monofásica. Estas interferencias se clasifican en modo común y modo diferencial. La manera más usual de mitigarlas es mediante el empleo de filtros de red. Los métodos actuales de diseño de filtros de red abordan la mitigación de este tipo de interferencias por separado: no tienen en cuenta que ambos tipos de señales (modo común y diferencial) interaccionan entre sí y se transfieren energía en cualquier tipo de asimetría originada por los equipos electrónicos o por los mismos filtros. Este hecho produce frecuentemente situaciones inesperadas: inefectividad de los filtros de red, aparición de interferencias en modo común o diferencial inexplicables por la topología de los circuitos, selectividad en frecuencia del filtrado de las interferencias, procesos de radiación, etc. Este tipo de situaciones pueden ser analizadas y corregidas a partir de un análisis multimodal, que tenga en cuenta simultáneamente el modo común y el diferencial, y su interacción. El trabajo aquí expuesto pretende:- Desarrollar sistemas de medida multimodal para equipos electrónicos y filtros de red. Dichos sistemas deben tener en cuenta tanto el modo común, como el diferencial, como su interacción, y deben mejorar las prestaciones de los sistemas de medida normativos actuales.- Hallar modelos equivalentes desde un punto de vista multimodal (teniendo en cuenta simultáneamente el modo común, el diferencial y su interacción) tanto de equipos electrónicos como de filtros de red.- Desarrollar una metodología de predicción de las interferencias conducidas que el equipo electrónico suministra a la red eléctrica a través del filtro de red al cual está conectado a partir de los modelos multimodales equivalentes propuestos para ambos dispositivos.PALABRAS CLAVE: Compatibilidad electromagnética, filtro de red, equipo electrónico, circuito equivalente, emisión conducida, modo común, modo diferencial, impedancia de entrada, parámetros S. / One of the most important problems in EMC is the control of the common and differential mode interferences emitted or received by an electronic device through its single phase power-line cable. These interferences are mitigated using power-line filters. The present power-line filter methodologies treat separately the mitigation of this kind of interferences: they do not take into account that both modes interact and exchange energy at any kind of asymmetry originated by the devices connected to the power-line, or by the power-line filters themselves. This fact leads to unexpected situations: power-line filter infectivity, appearance of common and differential mode interferences not accountable by the circuit topology, frequency selectivity of the interferences, radiation processes, etc. This kind of situations can be analyzed and corrected using multimodal analysis, which takes into account at the same time the common mode, the differential mode and their interaction. This project aims to:- Develop accurate multimodal measurement systems for both electronic devices and power-line network filters. They have to consider the common and differential modes, and their interaction, and have to improve the features of present normative measurement systems. - Derive equivalent models from a multimodal point of view (taking into account simultaneously the common mode, the differential mode and their interaction) for both electronic devices and power-line filters.- Develop a methodology for predicting the level of conducted emissions that an electronic device supplies to the power-line network through the power-line filter to which it is connected, using the equivalent multimodal models proposed for both devices.KEYWORDS: Electromagnetic compatibility, power-line filter, electronic device, equivalent circuit, conducted emissions, common mode, differential mode, input impedance, S parameters.
95

Síntesis y estudio de derivados de 3H-fenoxazin-3-ona y Aminometilantraceno en disolución y soportados sobre sólidos mesoporosos tipo MCM-41 para su aplicación como sensores moleculares ópticos

Descalzo López, Ana Belén 06 May 2008 (has links)
En esta tesis se han desarrollado varias sondas fluorescentes y materiales híbridos para la detección óptica de diversas especies tanto catiónicas (Hg2+ y metales alcalinotérreos), aniónicas (ATP, carboxilatos de cadena larga y fluoruro) como neutras (vapores orgánicos). El núcleo cromofórico principal estudiado ha sido la 7-amino-3H-fenoxazin-3-ona, cuya estructura consiste en un grupo amino que actúa como electrón dador en el proceso de transferencia interna de carga fotoinducida, y un grupo carbonilo como aceptor conectados a través del sistema electrónico p. Este cromóforo posee propiedades ópticas óptimas como elevados coeficientes de absorción molar y rendimientos cuánticos de fluoresecencia, con longitudes de onda de absorción y emisión centradas por encima de los 500 nm. Estudios espectroscópicos de UV/Vis de una serie de sistemas modelo revelan que el aumento de la fuerza electrón dadora del sustituyente introducido a través del grupo amino genera un aumento del rendimiento cuántico de fluorescencia y desplazamientos batocrómicos de las bandas de absorción y emisión. En base a esto, la introducción de un grupo electrón dador débil (urea) como receptor ha permitido obtener un fluoroionóforo capaz de detectar la presencia de aniones (acetato y dihidrogenfosfato) en disolventes orgánicos con un aumento en la fluorescencia y un cambio de color de naranja a rosa inducidos por la coordinación del anión. En el caso del fluoruro, anión más básico, se pone de manifiesto mediante estudios espectroscópicos de UV/Vis y 1H-RMN la desprotonación del colorante. Otro aspecto interesante de este cromóforo es su capacidad para actuar como un receptor ditópico en ciertas situaciones. La protonación y coordinación de cationes metálicos tiene lugar a través del grupo carbonilo. Mediante la introducción de diversos receptores a través del nitrógeno (ligandos macrocíclicos tipo éter corona para la coordinación de cationes alcalinotérreos y tipo aza-tia-oxa para la coordinación d / Descalzo López, AB. (2004). Síntesis y estudio de derivados de 3H-fenoxazin-3-ona y Aminometilantraceno en disolución y soportados sobre sólidos mesoporosos tipo MCM-41 para su aplicación como sensores moleculares ópticos [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/1851 / Palancia

Page generated in 0.0303 seconds