• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 519
  • 193
  • 67
  • 65
  • 59
  • 45
  • 14
  • 9
  • 8
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • Tagged with
  • 1287
  • 1287
  • 208
  • 203
  • 188
  • 185
  • 130
  • 128
  • 124
  • 120
  • 109
  • 104
  • 99
  • 97
  • 82
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
421

Grön IT -Vad krävs av Scania InfoMate för att bli en Grön IT leverantör? / Green IT -What does it take for Scania InfoMate to become a Green IT solution provider?

Kristiansson, Emelie January 2009 (has links)
This master thesis was performed at InfoMate which is the IT organisation within Scania CVAB. Scania is a global company with operations in Europe, Latin America, Asia, Africa andAustralia. Scania is the world’s third largest manufacturer of heavy trucks and heavy bussegment. InfoMate’s mission is to provide the global business activities with IT solutions thatsupport the core activity. Scania InfoMate is represented in Sweden, France, Holland andLatin America with totally 650 employees.The objective for this thesis is to evaluate the environmental work within InfoMate andpropose improvements. The thesis explains how a green approach of IT can increaseprofitability of the company. Green IT doesn’t only consist of taking responsibility of theenvironmental change; it is as much about decreased cost, increased efficiency and anenhanced image.Green IT is much about reducing energy consumption. The thesis makes it clear that it alreadyexist an ongoing work with this within InfoMate but with the economical approach as thedriving force. Mainly is it the increment in the number of virtualized servers that hasdecreased the energy consumption per server. However, there is a great potential to dosubstantial improvements. An important part of the environmental work is to engage theemployees by education, as well as connect the environmental policy of Scania to InfoMate,and make it visible to one and all within the IT organisation. Last but not the least, it isimportant to do measurements and follow up how the environmental work proceeds and whatit results in, in a motivation purpose. It is also important to visualise what needs to focus on,to make the work more uniform and goal-oriented. / Uppsatsnivå: D
422

Energy, power, and office buildings : design and analysis of an off-peak cooling system using structural mass storage

Mathis, Rory Christopher January 1982 (has links)
Thesis (M.S.)--Massachusetts Institute of Technology, Dept. of Architecture, 1982. / MICROFICHE COPY AVAILABLE IN ARCHIVES AND ROTCH. / Includes bibliographical references. / As the electric utilities face ever increasing peak power production requirements, (mostly from the commercial sector) scheduled "time-of-day" pricing schemes have become imperative. At present, most conservation strategies for commercial buildings focus on the reduction of energy consumption orchestrated (justifiably) by t he expense of electrical energy for lighting and cooling which dominate their loads. However, these conservation schemes, such as higher efficiency lamps, various glazing techniques, etc., do not alter the time of consumption nor do they utilize the lower off-peak electrical rates. The results are as before; high energy costs due to peak (daytime) consumption, and projected savings from the various conservation strategies are overshadowed or not realized. This thesis investigates a decentralized off-peak cooling system for commercial office buildings utilizing the structural mass as the thermal storage medium. The system incorporates an exposed concrete ceiling slab cooled at night with imbedded chilled water pipes and taking full advantage of off-peak electrical rates. The ceiling/slab - waterpipe system is modeled via two-dimensional finite difference methods for transient analysis. The sensitivity of the system to pipe size and spacing, internal loads, water temperatures, and surface geometry is assessed. The analytical results suggest the potential for application, however, additional research must be undertaken to investigate the economic implications of fabrication and to more adequately determine the effects of non-planar surface geometry. / by Rory Christopher Mathis. / M.S.
423

Modelling the effects of alternatives in natural energy systems in small agriculturally oriented communities

Heeschen, Conrad Richard January 1977 (has links)
Thesis. 1977. M.Arch.A.S.--Massachusetts Institute of Technology. Dept. of Architecture. / MICROFICHE COPY AVAILABLE IN ARCHIVES AND ROTCH. / Bibliography : leaves 174-178. / by Conrad Heeschen. / M.Arch.A.S.
424

Effect of control parameters on energy consumption of a room heating system

Desai, Nainan Vijay January 2011 (has links)
Photocopy of typescript. / Digitized by Kansas Correctional Industries
425

Incorporation of energy performance data in the design process : heating and cooling load estimation and analysis in a computerized space allocation procedure

Andersson, Brandt Charles January 1977 (has links)
Thesis. 1977. M.Arch.--Massachusetts Institute of Technology. Dept. of Architecture. / MICROFICHE COPY AVAILABLE IN ARCHIVES AND ROTCH. / Includes bibliographical references. / by Brandt Andersson. / M.Arch.
426

Energy consumption prediction in software-defined wirelwss sensor networks. / Previsão de consumo de energia em redes de sensores sem fio definidas por software.

Nuñez Segura, Gustavo Alonso 20 February 2018 (has links)
Energy conservation is a main concern in Wireless Sensor Networks (WSN). To reduce energy consumption it is important to know how it is spent and how much is available during the node and network operation. Several previous works have proposed energy consumption models focused on the communication module, while neglecting the processing and sensing activities. Other works presented more complex and complete models, but lacked experiments to demonstrate their accuracy in real deployments. The main objective of this work is to design and to evaluate an accurate energy consumption model for WSN, which considers the sensing, processing, and communication modules usage. This model was used to implement two energy consumption prediction mechanism. One mechanism is based in Markov chains and the other one is based in time series analysis. The metrics to evaluate the model and prediction mechanisms performance were: energy consumption estimation accuracy, energy consumption prediction accuracy, and node\'s communication and processing resources usage. The energy consumption prediction mechanisms performance was compared using two implementation schemes: running the prediction algorithm in the sensor node and running the prediction algorithm in a Software-Defined Networking controller. The implementation was conducted using IT-SDN, a Software-Defined Wireless Sensor Network framework. For the evaluation, simulation and emulation used COOJA, while testbed experiments used TelosB devices. Results showed that considering the sensing, processing, and communication energy consumption into the model, it is possible to obtain an accurate energy consumption estimation for Wireless Sensor Networks. Also, the use of a Software-Defined Networking controller for processing complex prediction algorithms can improve the prediction accuracy. / A conservação da energia é uma das principais preocupações nas Redes de Sensores Sem Fio (WSN, do inglês Wireless Sensor Networks). Para reduzir o consumo de energia, é importante saber como a energia é gasta e quanta energia há disponível durante o funcionamento da rede. Diversos trabalhos anteriores propuseram modelos de consumo de energia focados no módulo de comunicação, ignorando o consumo por tarefas de processamento e sensoriamento. Outros trabalhos apresentam modelos mais completos e complexos, mas carecem de experimentos que demonstrem a exatidão em dispositivos reais. O objetivo principal deste trabalho é projetar e avaliar um modelo de consumo de energia para WSN que considere o consumo por sensoriamento, processamento e comunicação. Este modelo foi utilizado para implementar dois mecanismos de previsão de consumo de energia, um deles baseado em cadeias de Markov e o outro baseado em séries temporais. As métricas para avaliar o desempenho do modelo e dos mecanismos de previsão de consumo de energia foram: exatidão da estimativa de consumo de energia, exatidão da previsão de consumo de energia e uso dos recursos de comunicação e processamento do nó. O desempenho dos mecanismos de previsão de consumo de energia foram comparados utilizando dois esquemas de implementação: rodando o algoritmo de previsão no nó sensor e rodando o algoritmo de previsão em um controlador de rede definida por software. A implementação foi conduzida utilizando IT-SDN, um arcabouço de desenvolvimento de redes de sensores sem fio definidas por software. A avaliação foi feita com simulações e emulações utilizando o simulador COOJA e ensaios com dispositivos reais utilizando o TelosB. Os resultados mostraram que considerando o consumo de energia por sensoriamento, processamento e communicação, é possivel fazer uma estimativa de consumo de energia em redes de sensores sem fio com uma boa exatidão. Ainda, o uso de um controlador de rede definida por software para processamento de algoritmos de previsão complexos pode aumentar a exatidão da previsão.
427

Leitura automatizada de medidores de consumo de energia elétrica eletromecânicos. / Automated reading of eletromechanical electric energy consumption meter.

Bizarria, José Walter Parquet 02 June 2006 (has links)
BIZARRIA, J. W. P. Leitura automatizada de medidores de consumo de energia elétrica eletromecânicos. 2006. 255 f. Tese (Doutorado) - Escola Politécnica, Universidade de São Paulo, São Paulo, 2006. Este trabalho aborda o projeto conceitual de um sistema voltado para a leitura automatizada de medidores de consumo de energia elétrica eletromecânicos, residenciais, com transdutores por indução acoplados a registradores mecânicos ciclométricos, sendo esse sistema denominado de Sistema Automatizado para Leitura de Medidores Eletromecânicos (SALME). Nessa abordagem, são explorados conceitos que visam contribuir para a evolução desse tipo de medidor e de outros, aos quais esses conceitos possam ser estendidos. Os elementos desse sistema oferecem contribuição voltada para a busca de soluções dos atuais problemas existentes, principalmente no que se refere à automatização dos processos de aquisição de dados do consumo de energia elétrica, e no combate às fraudes. O SALME está fundamentado numa arquitetura de sistema distribuído que separa o medidor em duas unidades: uma destinada para a medição do consumo; outra para a visualização dos dados referentes à leitura do medidor. O modelo de aplicação dessa arquitetura prevê a instalação da unidade de medição no âmbito da via pública, sendo a unidade de visualização instalada no âmbito da unidade consumidora. A instalação da unidade de medição no âmbito da via pública dificulta a implementação e utilização de circuitos não autorizados, que impeçam ou interfiram na medição dos corretos valores de consumo de energia elétrica, a serem utilizados para a cobrança desse insumo. A instalação da unidade de visualização no âmbito da unidade consumidora proporciona ao consumidor a leitura do medidor, prevista para esse tipo de aplicação. Nesse sistema, a leitura do medidor é automatizada, de forma que a aquisição dos dados de leitura dos consumos pode ser realizada no âmbito da via pública, por meio do uso de coletores de dados ou por interligação a sistemas de comunicação que utilizam redes de longa distância. Para a comunicação com os coletores de dados, é prevista a utilização da radiação infravermelha como meio de comunicação sem fio. A automatização da leitura dos medidores é fundamentada no conceito de leitura eletrônica do registrador mecânico ciclométrico, sendo exploradas abordagens que envolvem: a conversão optoeletrônica analógica; a aquisição e o processamento de imagens, e a conversão optoeletrônica digital. Os resultados obtidos nos ensaios práticos efetuados com os protótipos dos elementos do SALME foram satisfatórios, sendo validados os princípios de funcionamento desses elementos, ratificando os conceitos propostos, mostrando que os objetivos previstos neste trabalho foram alcançados em toda a sua plenitude. / BIZARRIA, J. W. P. Automated reading of electromechanical electric energy consumption meter. 2006. 255 f. Thesis (Doctoral) - Escola Politécnica, Universidade de São Paulo, São Paulo, 2006. This work embodies a conceptual design of a system focalized in automatic reading of electromechanical electric energy consumption meter, residential, with inductive transducers coupled together with cyclic mechanical registers, being that system called by Automated System for Reading of Electromechanical Meter (ASREM). On that approach are explored concepts that aim to contribute for evolution of that type of meter and others of which those concepts can be extended. The elements of that system offer contribution dedicated for the search of solutions of the current problems, mainly referring to automation of data acquisition processes of electric power consumption, and against to swindle. ASREM is based on architecture of distributed system that splits the meter into two units, being one destined to consumption measurement and other for visualization of the data related to the meter reading. The model of application of that architecture, foresees the installation of a measurement unit in the ambit of public electrical network, being the unit of visualization installed in the ambit of consumer demand. The installation of measurement unit in the ambit of public electrical network, obstructs the implementation and use of non authorized circuits that prevent or interfere in the measurement of correct values of electric power consumption to be utilized for the collection of that tariff. The installation of unit for visualization in the ambit of consumer demand, provides to the consumer the reading of the meter foreseen for that type of application. On that system the reading of the meter is automated, so that the acquisition of the reading data of the consumptions it can be accomplished in the ambit of public electrical network, by means of usage either by data collectors or by interconnection to communication systems that use long distance networks. For the communication with the data collectors that is forecasted the utilization of infrared radiation as a mean of wireless communication. The automation of meters reading is based on concept of electronic reading of the cyclic mechanical register, being explored approaches that involve: the analogical optoelectronic conversion, acquisition and image processing, and digital optoelectronic conversion. The results obtained in the practical tests performed with the prototypes of ASREM elements, were satisfactory, being validated the principles of operation of those elements, ratifying the proposed concepts, showing that the objectives foreseen in this work were fully reached.
428

Estudo comparativo da absorção e dessorção de dióxido de carbono em colunas para solução de aminas: monoetileno amina e monodietil amina/piperazina. / Comparative study of absorption and dessorption of carbon dioxide in columns for solution of amines: monoethylene amine and monodietyl amine / piperazine.

Bianchini, Roberto Hasson Levi 07 December 2017 (has links)
Este trabalho tem por objetivo avaliar o desempenho econômico - custo operacional energético e custo de investimento - do processo de absorção químicaseguida de dessorção de dióxido de carbono (CO2),comparando-se os seguintes solventes da classe das aminas: monoetanolamina (MEA) e a mistura metildietanolamina/piperazina (MDEA/PZ), utilizando-se o simulador de processo Aspen Plus®. Para a avaliação da operação de absorção, recorreu-se primeiramente à implementação de um modelo matemático de absorção desenvolvido em planilha eletrônica,para comparar e validar o comportamento dos perfis de temperaturas resultantes das simulações com o Aspen Plus. Este modelo foi desenvolvido a partir dos parâmetros de transferência de massa e variáveis de processo pré especificadas. Tanto no modelo em planilha como no modelo do AspenPlus®, o dimensionamento das colunas de absorção e dessorção foram definidos a partir das variáveis de processo, considerando-se aspectos hidrodinâmicos e de transferência de massa. As simulações foram realizadas inicialmente em ciclo aberto, com as concentrações iniciais de aminas, e em seguida em ciclo fechado, com acorrente de fundo da coluna de dessorção reciclada para a alimentação da coluna de absorção, com coeficientes de carga praticamente iguais, emulando-se, assim o o ciclo fechado. Com base na literatura, estabeleceram-se as seguintes condições: a razão de 1:4 (em massa) entre a vazão de gás da mistura ar/CO2 e a vazão de solução de amina; faixas de pressões de operação de 1,0 bar(abs) a 1,3 bar(abs), na absorção, e 2,2 bar(abs.), na dessorção; eficiência de 94% de recuperação de CO2. Os dados apresentados, comparando-se MEA e a mistura MDEA/PZ revelaram uma redução no fator de consumo energético no refervedor na ordem de 15 % no sistema de dessorção empregando-se MDEA/PZ. Estimativas de custo operacionais e custo de investimento foram computados e também incluídos para a análise econômica. O crédito obtido pela diferença no custo operacional anual, entre as duas alternativas avaliadas, variou entre US$ 50.000,00/ano e US$ 140.000,00, em função da volatilidade do preço do insumo energético. / The aim of this work is to evaluate the economic performance - energy operational cost and investment cost - of the chemical absorption process using carbon dioxide desorption (CO2), comparing the following solvents of the amine class: monoethanolamine (MEA) and (MDEA / PZ), using the Aspen Plus® process simulator. For primary evaluation purpose of the absorption operation, a mathematical absorption model was developed in a spreadsheet, to compare and validate the behavior of the temperature profiles resulting from simulations with Aspen Plus. This model was developed from the pre-specified mass transfer parameters and process variables. Both in the spreadsheet model and in the AspenPlus® model, the dimensioning of the absorption and desorption columns were defined from the process variables, considering hydrodynamic and mass transfer aspects. The simulations were performed initially in the open cycle, with the initial concentrations of amines, and then in closed cycle, with the bottom stream of the desorption column recycled to feed the absorption column, with almost equal load coefficients, emulating the closed loop. Based on the literature, the following conditions were established: the ratio of 1: 4 (by mass) between the gas flow of the air / CO2 mixture and the flow rate of the amine solution; operating pressure ranges of 1.0 bar (abs) at 1.3 bar (abs) at absorption, and 2.2 bar (abs.) at desorption; efficiency of 94% CO2 recovery. The data presented, comparing MEA and the MDEA / PZ mixture revealed a reduction in the energy consumption factor in the order of 15% in what concerns the desorption system using MDEA / PZ. Estimates of operating costs and investment costs were computed for economic analysis. The credit obtained by the difference in the annual operating cost between the two alternatives ranged from US $ 50,000.00 / year to US $ 140,000.00, due to the volatility of the energy price.
429

Custo de energia elétrica no bombeamento de poços em áreas de intensa explotação: estudo de caso em São José do Rio Preto - SP / Eletric energy costs on pumping wells in an intensive explotation area: São José do Rio Preto - SP case study

Simonato, Mateus Delatim 04 April 2013 (has links)
Esta pesquisa objetivou a avaliação de custos de energia elétrica no bombeamento de poços, em área de intensa explotação das águas subterrâneas do Sistema Aquífero Bauru (SAB), em São José do Rio Preto - SP (SJRP) e foi conduzida em sinergia com uma abordagem multifocal de avaliação como ferramenta à gestão do uso das águas subterrâneas em áreas urbanas. A área de estudo, com 728 km2 , abrange quase totalmente o município, onde o modelo de uso das águas subterrâneas provocou rebaixamentos dos níveis potenciométricos do SAB na zona urbana, evidenciados em modelos numéricos de fluxo subterrâneo. O desenvolvimento desta pesquisa contemplou a seleção, análise e interpretação de dados do cadastro de poços do Departamento de Águas e Energia Elétrica e a geração de mapas de profundidade dos níveis de água, visando à caracterização do uso das águas subterrâneas em SJRP e aos cálculos do consumo de energia elétrica na explotação. As águas subterrâneas do SAB são responsáveis por 64% de todo o suprimento hídrico de SJRP, explotadas por 180 poços de abastecimento público e quase 1.800 poços particulares para usos diversos, segundo a base de dados de 2008. Os poços particulares, na grande maioria não outorgados, respondem por 60% de toda a captação do SAB, evidenciando forte dependência do suprimento às alternativas individuais de infraestrutura hídrica. A comparação entre diferentes cenários de explotação simulados por modelação numérica de fluxo subterrâneo constatou a ocorrência de incrementos no consumo e no custo de energia elétrica na explotação, caracterizando a externalidade decorrente do modelo de uso das águas subterrâneas do SAB em SJRP a todos os usuários; e também o aumento da despesa com energia na captação dos poços públicos provocado por influência da captação dos poços particulares, caracterizando a externalidade gerada pelo uso privado à coletividade. Avaliou-se também que os sistemas de bombeamento instalados nos poços possuem baixo rendimento, demandando maior consumo de energia na explotação de água. Esta pesquisa concluiu que ocorre a superexplotação do SAB na zona urbana de SJRP, porém, com a possibilidade de ser mitigada com o adequado manejo das disponibilidades hídricas subterrâneas adjacentes ao perímetro urbano. / This research aimed to evaluate the cost of electrical energy involving the pumping of wells in areas of intensive groundwater use in Bauru Aquifer System (BAS), in São José do Rio Preto - SP (SJRP) and it was conducted as a focusing contribute on management tool for the groundwater use in urban areas. The study area, 728 km2 , means almost the whole municipal total area, in which the pumping of groundwater has caused aquifer drawdown effects on BAS in the urban area, as it is evidenced by groundwater flow mathematical models. The development of this resource assembles the selection, analysis and data interpretation of the well registered with the Water Management State Agency besides designing of water table depth maps, in order to provide the characterization of the groundwater use in SJRP and the calculation of electrical energy consumption along the exploitation. BAS supplies 64% of groundwater to the whole water supply of SJRP, exploited by 180 municipal wells and almost 1.800 private wells dedicated for several uses, accordingly to the data from 2008. Water supply system is strongly dependable of the private wells that most of them are not licensed. The private wells are responsible for 60% of the total BAS explotation. The comparison between the different exploitation scenery simulated by groundwater flow mathematical models shows the occurrence of electrical energy consumption and cost increments along the exploitation, meaning an externality to all users due BAS groundwater development in SJRP; and also the increment of electrical energy spends for municipal wells caused by the influence of the exploitation of the private wells, meaning an externality caused by the private use to collectivity. It was also analyzed the pumping system installed in the well that has low performance, requiring a greater energy consumption during the water exploitation. This research concluded that occurs an overexploitation of BAS in the urban area of SJRP, however, there are possibilities to mitigate considering the appropriated management of the safe yield in the surroundings of the urban perimeter.
430

Polpa cítrica na restrição alimentar qualitativa para suínos em terminação /

Watanabe, Pedro Henrique. January 2007 (has links)
Orientadora: Maria Cristina Thomaz / Banca: Hirasilva Borba Alves de Souza / Banca: Jacinta Diva Ferrugem Gomes / Resumo: Foram conduzidos dois ensaios para avaliar a utilização da polpa cítrica como ingrediente em programas de restrição alimentar qualitativa para suínos em terminação. No primeiro ensaio foram utilizados 16 suínos machos castrados da linhagem Topigs, com peso inicial de 80,5l4,7 kg, para a avaliação biológica da polpa cítrica. Por apresentar 18,85% de fibra em detergente neutro e 41,18% de fibra solúvel em detergente neutro, a polpa cítrica mostrou-se como um ingrediente viável a ser utilizado em programas de restrição alimentar qualitativa. No segundo ensaio foram utilizados 36 suínos machos castrados com peso inicial de 83,7l5,1 kg, recebendo rações com níveis de 0, 10, 20 e 30% de polpa cítrica. Os animais foram abatidos com peso próximo de 130 kg, sendo avaliados quanto ao desempenho, pesos de órgãos do trato digestório, parâmetros séricos, características de carcaça, qualidade da carne e avaliação econômica do uso das dietas. Até 10% de inclusão, a polpa cítrica não piorou o desempenho, porém observou-se reduções no peso e rendimento das carcaças devido ao aumento dos pesos dos órgãos do trato digestório. A inclusão de polpa cítrica não piorou a qualidade da carne, podendo ser utilizada na alimentação de suínos em terminação, entretanto, sua inclusão não proporcionou retorno econômico que justificasse seu uso em programas de restrição alimentar. / Abstract: Two assays were conducted to evaluate citrus pulp as an ingredient in qualitative feed restriction programs for growing pigs. In the first assay, 16 barrows of Topigs lineage with 80.5l4.7 kg of body weight were used to determine the biological value of citrus pulp. The citrus pulp presented 18.85% of neutral detergent fiber and 41.18% of neutral detergent soluble fiber, and was considered as a viable ingredient to be used in qualitative feed restriction programs. In the second assay, 36 barrows initially weighing 83.7l5.1 kg were allotted into four diets with different levels (0, 10, 20 and 30%) of citrus pulp. Animals were fed until they reached 130 kg. At this moment, pigs were abated and the effects on performance, weight of gastrointestinal tract organs, serum parameters, carcass traits, meat quality and economical analysis were evaluated. Up to 10% of inclusion, citrus pulp did not act negatively on animal’s performance but body weight and total dressing were reduced due to higher weight of gastrointestinal tract organs. As citrus pulp did not cause any undesirable effects on meat quality, this ingredient was shown as an alternative in diets for finishing pigs. However, the economic analysis demonstrated that the inclusion of citrus pulp in diets was not profitably enough to justify its use in feed restriction programs, as no better reward indexes were observed. / Mestre

Page generated in 0.1533 seconds