1 |
Proposição e avaliação de um sistema experimental de processos físicos e químicos para tratamento de lixiviadoLINS, Eduardo Antonio Maia 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T17:37:01Z (GMT). No. of bitstreams: 2
arquivo2411_1.pdf: 5312881 bytes, checksum: c64ce8cf019e06d5c86303daf17de7b4 (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2011 / Faculdade de Amparo à Ciência e Tecnologia do Estado de Pernambuco / O tratamento de lixiviado proveniente de aterros de resíduos sólidos urbanos, tornou-se
um grande desafio para a comunidade científica uma vez que nem sempre um sistema
de tratamento adotado para uma determinada região torna-se adequado para outra, em
função da grande variabilidade da composição do lixiviado. Os sistemas de tratamento a
serem adotados devem levar em consideração as particularidades da região a fim de
tornar o sistema economicamente viável. De um modo geral, a concepção adotada como
escopo desta pesquisa consistiu em um sistema de baixo custo, fácil implantação,
simples operação e com boa remoção de poluentes. Durante as análises realizadas em
escala piloto, adotou-se uma vazão em fluxo contínuo de 0,1 L/s , que equivale a cerca
de 10% da vazão real do Aterro da Muribeca, onde as características físico-químicas
deste lixiviado serviram de base para o dimensionamento da estação piloto. A estação
piloto projetada é composta por três etapas: precipitação química, stripping da amônia e
barreira reativa com carvão ativado. Os resultados deste estudo apresentaram um
desempenho médio de remoção de DBO (>80%) e DQO (>85%) superior a eficiência
de 60% de remoção exigida pela legislação estadual mineira para tratamento de
lixiviado, tornando-se suficiente ao lançamento em rios classe 3. A concentração de
amônia, para todos os ensaios realizados, encontrou-se acima do permitido pela
legislação federal, em função do baixo tempo de detenção adotado para a etapa do
stripping da amônia. Quanto à cor do lixiviado, de um modo geral, não conferiu
mudança de coloração acentuada ao corpo receptor após seu lançamento, estando em
concordância com a legislação federal. Estimando-se o custo final do tratamento em
escala real, obteve-se um valor médio abaixo do praticado no Brasil
|
2 |
Remoção de matérias orgânica e nitrogenada de esgoto sanitário em reator de leito estruturado, em escala piloto / Removal of organic and nitrogen matters from sewage in a structured-bed reactor on a pilot scaleMurata, Kiemi de Brito 25 September 2015 (has links)
O processo de nitrificação e desnitrificação simultâneas (NDS) permite alcançar a remoção combinada de matérias carbonácea e nitrogenada em uma única unidade. O reator de leito estruturado, com biomassa imobilizada e recirculação interna, apresenta características positivas para que estes processos envolvidos ocorram, tais como propiciar a formação de biofilme e evitar a colmatação do leito. Esta configuração tem sido estudada com êxito em reatores em escala de bancada para tratamento de esgoto. Nesta pesquisa foi utilizado um reator de leito estruturado em escala piloto com a finalidade de avaliar sua implantação, eficiência e estabilidade tratando esgoto doméstico em condições reais para futura aplicação em pequenas comunidades, condomínios residenciais entre outros como sistema descentralizado. O reator foi construído em fibra de vidro, de formato cilíndrico, com diâmetro interno de aproximadamente 0,80 m e 2,0 m de altura. O volume total foi de aproximadamente 0,905 m3 e o volume útil de 0,642 m3. A operação foi realizada sob condições de aeração contínua e intermitente e os tempos de detenção hidráulica (TDH) testados foram de 48, 36 e 24 horas. A remoção de DQO manteve-se acima de 90% com TDH de 48 e 36 horas. A melhor eficiência de remoção de nitrogênio total foi de 72,4 ± 6,4%, sob TDH de 48 horas e a aeração intermitente, com 2 horas de aeração e 1 hora não aerada. A concentração de oxigênio dissolvido (OD) média de 2,8 ± 0,5 mg.L-1 na fase aerada e temperatura média de 24,7 ± 1,0 °C. Nesse mesmo período, a eficiência média de remoção de DQO foi de 94 ± 4 %. Apesar das dificuldades apresentadas no controle da aeração, as eficiências das remoções obtidas indicaram que o reator de leito estruturado e aeração intermitente (LEAI) se apresenta como uma alternativa promissora em escala plena, requerendo ajustes para construção e incremento da estabilidade da NDS. / The simultaneous nitrification and denitrification (SND) process allow achieving a combined nitrogen and carbon removal in a single unit. The structured-bed reactor, with immobilized biomass and internal recirculation, presents positive characteristics for occurrence of these involved processes, such as providing biofilm formation and prevent clogging. This configuration have been study successfully in a bench scale for sewage treatment. In this research was used a structured-bed reactor in a pilot scale in order to evaluate its implantation, efficiency and stability treating sewage in real conditions to future application in small communities, residential condominium among others, as decentralized treatment. The reactor was constructed with cylindrical glass fiber modules, with internal diameter of 0.8 m and 2.0 m height. The total volume was about 0.905 m3 and 0.642 m3 working volume. It was worked under continuous and intermittent aeration conditions and the tested hydraulic retention times (HRT) were 48, 36 e 24 hours. The maximum total nitrogen removal was 72.4 ± 6.4% ; the HRT was 48 hours with intermittent aeration, in which 2 hours in aeration and 1-hour nonaeration. An average dissolved oxygen (DO) concentration of 2.8 ± 0.5 mg.L-1 in the aerated time and an average temperature of 24.7 ± 1.0°C. In the same period, the average COD removal was 94 ± 4%. Despite of the difficulties presented in aeration control, the obtained removals indicated the structured-bed reactor subjected to recirculation and intermittent aeration (SBRRIA) can be a promising alternative in full scale, demanding adjustments to improve the reactor construction and the SND stability.
|
3 |
Remoção de matérias orgânica e nitrogenada de esgoto sanitário em reator de leito estruturado, em escala piloto / Removal of organic and nitrogen matters from sewage in a structured-bed reactor on a pilot scaleKiemi de Brito Murata 25 September 2015 (has links)
O processo de nitrificação e desnitrificação simultâneas (NDS) permite alcançar a remoção combinada de matérias carbonácea e nitrogenada em uma única unidade. O reator de leito estruturado, com biomassa imobilizada e recirculação interna, apresenta características positivas para que estes processos envolvidos ocorram, tais como propiciar a formação de biofilme e evitar a colmatação do leito. Esta configuração tem sido estudada com êxito em reatores em escala de bancada para tratamento de esgoto. Nesta pesquisa foi utilizado um reator de leito estruturado em escala piloto com a finalidade de avaliar sua implantação, eficiência e estabilidade tratando esgoto doméstico em condições reais para futura aplicação em pequenas comunidades, condomínios residenciais entre outros como sistema descentralizado. O reator foi construído em fibra de vidro, de formato cilíndrico, com diâmetro interno de aproximadamente 0,80 m e 2,0 m de altura. O volume total foi de aproximadamente 0,905 m3 e o volume útil de 0,642 m3. A operação foi realizada sob condições de aeração contínua e intermitente e os tempos de detenção hidráulica (TDH) testados foram de 48, 36 e 24 horas. A remoção de DQO manteve-se acima de 90% com TDH de 48 e 36 horas. A melhor eficiência de remoção de nitrogênio total foi de 72,4 ± 6,4%, sob TDH de 48 horas e a aeração intermitente, com 2 horas de aeração e 1 hora não aerada. A concentração de oxigênio dissolvido (OD) média de 2,8 ± 0,5 mg.L-1 na fase aerada e temperatura média de 24,7 ± 1,0 °C. Nesse mesmo período, a eficiência média de remoção de DQO foi de 94 ± 4 %. Apesar das dificuldades apresentadas no controle da aeração, as eficiências das remoções obtidas indicaram que o reator de leito estruturado e aeração intermitente (LEAI) se apresenta como uma alternativa promissora em escala plena, requerendo ajustes para construção e incremento da estabilidade da NDS. / The simultaneous nitrification and denitrification (SND) process allow achieving a combined nitrogen and carbon removal in a single unit. The structured-bed reactor, with immobilized biomass and internal recirculation, presents positive characteristics for occurrence of these involved processes, such as providing biofilm formation and prevent clogging. This configuration have been study successfully in a bench scale for sewage treatment. In this research was used a structured-bed reactor in a pilot scale in order to evaluate its implantation, efficiency and stability treating sewage in real conditions to future application in small communities, residential condominium among others, as decentralized treatment. The reactor was constructed with cylindrical glass fiber modules, with internal diameter of 0.8 m and 2.0 m height. The total volume was about 0.905 m3 and 0.642 m3 working volume. It was worked under continuous and intermittent aeration conditions and the tested hydraulic retention times (HRT) were 48, 36 e 24 hours. The maximum total nitrogen removal was 72.4 ± 6.4% ; the HRT was 48 hours with intermittent aeration, in which 2 hours in aeration and 1-hour nonaeration. An average dissolved oxygen (DO) concentration of 2.8 ± 0.5 mg.L-1 in the aerated time and an average temperature of 24.7 ± 1.0°C. In the same period, the average COD removal was 94 ± 4%. Despite of the difficulties presented in aeration control, the obtained removals indicated the structured-bed reactor subjected to recirculation and intermittent aeration (SBRRIA) can be a promising alternative in full scale, demanding adjustments to improve the reactor construction and the SND stability.
|
4 |
Reator híbrido associando reator UASB e reator radial de leito fixo (RRLF), em escala piloto, no tratamento de esgoto sanitário / not availableLopes, Alexandre Colzi 10 June 2005 (has links)
Os sistemas combinados anaeróbio/aeróbio para tratamento de esgotos sanitários têm sido considerados alternativas viáveis do ponto de vista técnico-econômico em relação aos sistemas tradicionais. Este trabalho apresenta os resultados obtidos com uma nova configuração de reator, composto por uma unidade central - um reator anaeróbio de manta de lodo (UASB) modificado de 286 L, associado a um reator radial aerado de leito fixo (RRLF) de 215 L, disposto de maneira a circundar a zona de separação sólido/líquido/gás do reator UASB. A principal modificação no reator UASB foi, portanto, a incorporação, junto à sua parede externa, do RRLF. A alimentação do RRLF com o efluente do UASB dá-se através de aberturas laterais na parede do UASB, o que permitiu eliminar as calhas de coleta e sistemas de alimentação do segundo reator. Esse sistema foi alimentado com esgoto sanitário obtido da rede coletora de esgotos do campus da USP de São Carlos. Esperava-se obter remoção considerável de matéria orgânica solúvel e particulada, bem como a remoção parcial de nitrogênio. Foram obtidas eficiências médias de remoção de matéria orgânica (expressa como demanda química de oxigênio - DQO) e de sólidos suspensos voláteis (SSV), de 80% e 89%, respectivamente. Em condições de operação estável, os valores de DQO e SSV no efluente atingiram 110 mg/L e 16 mg/L, respectivamente. Observou-se, também, que o sistema apresentou grande estabilidade operacional, tendo a taxa de carregamento orgânico volumétrica atingido valores da ordem de 4,0 Kg DQO.m-3d-1. Nessas condições, o sistema atingiu eficiências de remoção de DQO e SSV da ordem de 90%. O sistema misto ensaiado mostrou ser uma configuração promissora, pois promoveu a remoção eficiente de matéria orgânica e de sólidos suspensos. Considera-se, no entanto, a necessidade de se introduzirem modificações no projeto RRLF que permitam o estabelecimento dos processos de nitrificação e desnitrificação nesse reator, uma vez que foi obtida baixa eficiência de nitrificação e, conseqüentemente, a remoção de nitrogênio foi prejudicada. / Integrated anaerobic/aerobic systems have been considered feasible alternatives concerning technical and economic aspects for treating domestic wastewaters. This paper presents the results obtained from the operation of this new reactor configuration, made up of a central unit - an upflow anaerobic sludge blanket reactor (UASB), with a working volume of 286 L, associated to a radial-flow aerobic immobilized-biomass (RAIB), with a working volume of 215 L. The RAIB reactor circles the solid/liquid/gas separation zone. The main modification in the UASB reactor concerns this association with the RAIB. The UASB effluent was distributed through openings along its side walls to the RAIB, allowing the elimination of collecting channels and feeding devices from the latter reactor. The objective of this work was to promote organic matter (raw and soluble) and nitrogen removal from domestic sewage. Organic matter (as COD) and volatile suspended solids removal achieved efficiencies of 80% and 89%, respectively. Under stable operational conditions, the system effluent presented COD and volatile suspended solids values of 110 mg/L and 16 mg/L, respectively. Efficiencies of 90% for COD and volatile suspended solids removal were achieved with a organic loading rate of 4,0 Kg COD.m-3.d-1. This integrated system has shown to be a valid configuration, efficiently removing organic matter and suspended solids from the domestic wastewater. However, contrarily to expectations based on the previous studies with RAIB, nitrification was poor. Therefore, modifications to the RAIB design must be considered for the establishment of nitrogen removing processes.
|
5 |
Reator híbrido associando reator UASB e reator radial de leito fixo (RRLF), em escala piloto, no tratamento de esgoto sanitário / not availableAlexandre Colzi Lopes 10 June 2005 (has links)
Os sistemas combinados anaeróbio/aeróbio para tratamento de esgotos sanitários têm sido considerados alternativas viáveis do ponto de vista técnico-econômico em relação aos sistemas tradicionais. Este trabalho apresenta os resultados obtidos com uma nova configuração de reator, composto por uma unidade central - um reator anaeróbio de manta de lodo (UASB) modificado de 286 L, associado a um reator radial aerado de leito fixo (RRLF) de 215 L, disposto de maneira a circundar a zona de separação sólido/líquido/gás do reator UASB. A principal modificação no reator UASB foi, portanto, a incorporação, junto à sua parede externa, do RRLF. A alimentação do RRLF com o efluente do UASB dá-se através de aberturas laterais na parede do UASB, o que permitiu eliminar as calhas de coleta e sistemas de alimentação do segundo reator. Esse sistema foi alimentado com esgoto sanitário obtido da rede coletora de esgotos do campus da USP de São Carlos. Esperava-se obter remoção considerável de matéria orgânica solúvel e particulada, bem como a remoção parcial de nitrogênio. Foram obtidas eficiências médias de remoção de matéria orgânica (expressa como demanda química de oxigênio - DQO) e de sólidos suspensos voláteis (SSV), de 80% e 89%, respectivamente. Em condições de operação estável, os valores de DQO e SSV no efluente atingiram 110 mg/L e 16 mg/L, respectivamente. Observou-se, também, que o sistema apresentou grande estabilidade operacional, tendo a taxa de carregamento orgânico volumétrica atingido valores da ordem de 4,0 Kg DQO.m-3d-1. Nessas condições, o sistema atingiu eficiências de remoção de DQO e SSV da ordem de 90%. O sistema misto ensaiado mostrou ser uma configuração promissora, pois promoveu a remoção eficiente de matéria orgânica e de sólidos suspensos. Considera-se, no entanto, a necessidade de se introduzirem modificações no projeto RRLF que permitam o estabelecimento dos processos de nitrificação e desnitrificação nesse reator, uma vez que foi obtida baixa eficiência de nitrificação e, conseqüentemente, a remoção de nitrogênio foi prejudicada. / Integrated anaerobic/aerobic systems have been considered feasible alternatives concerning technical and economic aspects for treating domestic wastewaters. This paper presents the results obtained from the operation of this new reactor configuration, made up of a central unit - an upflow anaerobic sludge blanket reactor (UASB), with a working volume of 286 L, associated to a radial-flow aerobic immobilized-biomass (RAIB), with a working volume of 215 L. The RAIB reactor circles the solid/liquid/gas separation zone. The main modification in the UASB reactor concerns this association with the RAIB. The UASB effluent was distributed through openings along its side walls to the RAIB, allowing the elimination of collecting channels and feeding devices from the latter reactor. The objective of this work was to promote organic matter (raw and soluble) and nitrogen removal from domestic sewage. Organic matter (as COD) and volatile suspended solids removal achieved efficiencies of 80% and 89%, respectively. Under stable operational conditions, the system effluent presented COD and volatile suspended solids values of 110 mg/L and 16 mg/L, respectively. Efficiencies of 90% for COD and volatile suspended solids removal were achieved with a organic loading rate of 4,0 Kg COD.m-3.d-1. This integrated system has shown to be a valid configuration, efficiently removing organic matter and suspended solids from the domestic wastewater. However, contrarily to expectations based on the previous studies with RAIB, nitrification was poor. Therefore, modifications to the RAIB design must be considered for the establishment of nitrogen removing processes.
|
6 |
Reator anaeróbio-aeróbio de leito fixo em escala piloto, com recirculação da fase líquida, aplicado ao tratamento de esgoto sanitário / Anaerobic-aerobic pilot-scale fixed-bed reactor, with recycle of the liquid phase, applied to the treatment of domestic sewageOliveira Netto, Antonio Pedro de 29 April 2011 (has links)
Este trabalho fundamentou-se na concepção, desenvolvimento tecnológico, ampliação de escala e avaliação do comportamento de sistema combinado anaeróbio-aeróbio de leito fixo e fluxo ascendente, com recirculação da fase líquida, para tratamento de esgoto sanitário. O reator, em escala piloto, foi construído em formato cilíndrico e confeccionado em fibra de vidro com volume total de aproximadamente 2,5 \'M POT.3\', com intuito de desenvolver um sistema capaz de operar como única unidade de tratamento para remoção de matéria orgânica e nitrogênio, reduzindo a geração de lodo e o consumo de energia pela combinação dos processos anaeróbio e aeróbio, possibilitando o aproveitamento das vantagens de cada um e minimizando seus aspectos negativos. Os melhores resultados operacionais foram encontrados para a etapa com tempo de detenção hidráulica total (TDH) de 12 horas e razão de recirculação (r) igual a 3,0, apresentando eficiências médias de remoção de DQO, \'N\'-NTK e SST de 92 ± 3%; 68 ± 11% e 75 ± 7%, respectivamente, com valores médios efluentes de 54 ± 22 mgDQO/L, 14 ± 10 mg \'N\'-NTK/L e 70 ± 42 mgSST/L. Os valores médios de carga orgânica volumétrica (COV) e carga volumétrica de nitrogênio (CVN) removidas foram de 1,08 ± 0,04 kgDQO/\'M POT.3\'.dia e 0,06 ± 0,02 kgNTK/\'M POT.3\'.dia para esta etapa. A estabilidade operacional durante a etapa com TDH de 12 h, a alta remoção de matéria orgânica e nitrogênio, sem a necessidade de adição de fonte exógena de carbono, para promover o processo de desnitrificação, e de suplementação de alcalinidade consumida durante a nitrificação, e a reduzida necessidade de manutenção devido à tecnologia de fabricação adotada, comprovam a viabilidade técnica de utilização do reator combinado de leito fixo como unidade compacta para pequenas comunidades ou vazões afluentes, para tratamento de esgoto sanitário. / This work was based on design, technology development, scale up and performance evaluation of an up-flow combined anaerobic-aerobic fixed bed system, with recycle of the liquid phase, for treatment of domestic sewage. The pilot scale reactor was built in a fiberglass cylindrical shape with a total volume of approximately 2.5 \'M POT.3\', aiming at the development of a system capable of operate as a single treatment unit for organic matter and nitrogen removal, with low sludge production and energy consumption by the advantages of combination of anaerobic and aerobic processes. The improved operating results were found for the condition with overall hydraulic retention time (HRT) of 12 hours and recycle ratio (r) equal to 3.0, with average removal efficiencies of COD, TKN and TSS of 92 ± 3%, 68 ± 11% and 75 ± 7%, respectively, with average effluent values of 54 ± 22 mgCOD/L, 14 ± 10 mgTKN/L and 70 ± 42 mgTSS/L. The average values of removed organic loading rate (OLR) and nitrogen volumetric loading (NVL) reached 1.06 ± 0.04 kgCOD/\'M POT.3.d and 0.06 ± 0.02 kgTKN/\'\'M POT.3\'.d for this phase. The operational stability during the stage with HRT of 12 h, the high organic matter and nitrogen removal, without addition of exogenous carbon source (electron donor) to promote the denitrification process, with no supplementation of alkalinity consumed during nitrification, and the reduced maintenance due to manufacturing technology adopted, proved the technical feasibility of the combined fixed-bed reactor as a compact unit for small communities or low inflow rates, for treatment of domestic sewage.
|
7 |
Reator anaeróbio-aeróbio de leito fixo em escala piloto, com recirculação da fase líquida, aplicado ao tratamento de esgoto sanitário / Anaerobic-aerobic pilot-scale fixed-bed reactor, with recycle of the liquid phase, applied to the treatment of domestic sewageAntonio Pedro de Oliveira Netto 29 April 2011 (has links)
Este trabalho fundamentou-se na concepção, desenvolvimento tecnológico, ampliação de escala e avaliação do comportamento de sistema combinado anaeróbio-aeróbio de leito fixo e fluxo ascendente, com recirculação da fase líquida, para tratamento de esgoto sanitário. O reator, em escala piloto, foi construído em formato cilíndrico e confeccionado em fibra de vidro com volume total de aproximadamente 2,5 \'M POT.3\', com intuito de desenvolver um sistema capaz de operar como única unidade de tratamento para remoção de matéria orgânica e nitrogênio, reduzindo a geração de lodo e o consumo de energia pela combinação dos processos anaeróbio e aeróbio, possibilitando o aproveitamento das vantagens de cada um e minimizando seus aspectos negativos. Os melhores resultados operacionais foram encontrados para a etapa com tempo de detenção hidráulica total (TDH) de 12 horas e razão de recirculação (r) igual a 3,0, apresentando eficiências médias de remoção de DQO, \'N\'-NTK e SST de 92 ± 3%; 68 ± 11% e 75 ± 7%, respectivamente, com valores médios efluentes de 54 ± 22 mgDQO/L, 14 ± 10 mg \'N\'-NTK/L e 70 ± 42 mgSST/L. Os valores médios de carga orgânica volumétrica (COV) e carga volumétrica de nitrogênio (CVN) removidas foram de 1,08 ± 0,04 kgDQO/\'M POT.3\'.dia e 0,06 ± 0,02 kgNTK/\'M POT.3\'.dia para esta etapa. A estabilidade operacional durante a etapa com TDH de 12 h, a alta remoção de matéria orgânica e nitrogênio, sem a necessidade de adição de fonte exógena de carbono, para promover o processo de desnitrificação, e de suplementação de alcalinidade consumida durante a nitrificação, e a reduzida necessidade de manutenção devido à tecnologia de fabricação adotada, comprovam a viabilidade técnica de utilização do reator combinado de leito fixo como unidade compacta para pequenas comunidades ou vazões afluentes, para tratamento de esgoto sanitário. / This work was based on design, technology development, scale up and performance evaluation of an up-flow combined anaerobic-aerobic fixed bed system, with recycle of the liquid phase, for treatment of domestic sewage. The pilot scale reactor was built in a fiberglass cylindrical shape with a total volume of approximately 2.5 \'M POT.3\', aiming at the development of a system capable of operate as a single treatment unit for organic matter and nitrogen removal, with low sludge production and energy consumption by the advantages of combination of anaerobic and aerobic processes. The improved operating results were found for the condition with overall hydraulic retention time (HRT) of 12 hours and recycle ratio (r) equal to 3.0, with average removal efficiencies of COD, TKN and TSS of 92 ± 3%, 68 ± 11% and 75 ± 7%, respectively, with average effluent values of 54 ± 22 mgCOD/L, 14 ± 10 mgTKN/L and 70 ± 42 mgTSS/L. The average values of removed organic loading rate (OLR) and nitrogen volumetric loading (NVL) reached 1.06 ± 0.04 kgCOD/\'M POT.3.d and 0.06 ± 0.02 kgTKN/\'\'M POT.3\'.d for this phase. The operational stability during the stage with HRT of 12 h, the high organic matter and nitrogen removal, without addition of exogenous carbon source (electron donor) to promote the denitrification process, with no supplementation of alkalinity consumed during nitrification, and the reduced maintenance due to manufacturing technology adopted, proved the technical feasibility of the combined fixed-bed reactor as a compact unit for small communities or low inflow rates, for treatment of domestic sewage.
|
Page generated in 0.0544 seconds