• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 56
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 58
  • 27
  • 19
  • 15
  • 15
  • 15
  • 12
  • 9
  • 9
  • 9
  • 7
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

UM ESPECTROMETRO \"MINI-ORANGE\" PARA ELECTRONS / A mini-orange spectrometer for electrons

Nelson Canzian da Silva 04 May 1990 (has links)
Foi projetado e construído um espectrômetro Mini-Orange (MO) para eléctrons, utilizando imãs planos permanentes e um detector de barreira de superfície. Foram determinadas as funções de transmissão de diferentes configurações do sistema, para energias entre 200-1100 keV. Foi desenvolvido um modelo matemático do sistema, a partir de solução analítica para o campo de um imã plano e da integração numérica da equação de movimento dos eléctrons no campo de MO. As funções de transmissão assim obtidas foram comparadas aos resultados experimentais e mostraram um bom acordo para energias baixas e intermediárias. / A Mini-Orange spectrometer for electrons was designed and built, using plane permanent magnets and a surface barrier detector. Transmission functions were obtained for various system configurations and for energies between 200-1100 keV. A mathematical model of the system was developed, using the analytical solution for the field of a plane magnet and the numerical integration of the equation of motion of the electrons in the MO magnetic field. The calculated transmission functions were compared to the experimental data, showing a good agreement for low and intermediate energies.
42

Dosimetria de nêutrons / Neutron dosimetry

Luciano Fratin 20 September 1993 (has links)
Instalações para irradiação com nêutrons foram projetadas e construídas, visando o estabelecimento de procedimentos de calibração de monitores e dosímetros de nêutrons. Uma fonte calibrada de ANTPOT.241 AmBe com atividade de ANTPOT.185 GBq, garantiu rastreabilidade às medidas realizadas, e possibilitou irradiações com taxas de dose que variaram entre 9 nSv s POT.-1 e 0,5 muuSv s POT.-1. No arranjo elaborado para irradiações com nêutrons térmicos, com fluxo calibrado, a taxa de dose utilizada foi 50 nSv s POT.-1. A calibração de um espectrômetro de esferas de Bonner permitiu o estabelecimento dos procedimentos de calibração com base em três métodos propostos por normas internacionais, mostrando serem apropriadas às dimensões da sala de irradiação projetada para essa finalidade. A decoração do espectro de nêutrons, a partir da determinação dos parâmetros de calibração para o detector de esferas de Bonner, permitiu determinar o espectro da fonte de ANTPOT.241 AmBe calibrada, com valores de taxa de fluência, taxa de dose equivalente e energia media, que corresponderam satisfatoriamente aos valores calculados esperados, possibilitando o uso de tal detector na dosimetria de área. Para a dosimetria pessoal, foi elaborado um sistema dosimétrico baseado no uso do polímero CR-39 e no ataque eletroquímico do mesmo. Para isso, foram projetadas e construídas uma câmara para o processamento do detector e uma fonte de alta tensão e alta frequência que mostraram-se adequadas às finalidades propostas. O dosímetro pessoal elaborado utiliza também material conversor (n, alfa) e seu principio de detecção possibilitou determinar um fator de calibração relacionando a resposta do detector com a dose recebida para nêutrons térmicos, epitérmicos e rápidos. Os parâmetros utilizados para o ataque eletroquímico foram: solução de KOH 6N, temperatura de 59°C, campo elétrico alternado de 20 kv IND.ppcm POT.-1, frequência de 2,0 kHz; para a detecção de nêutrons térmicos e epitérmicos o tempo de revelação empregado foi de 3 horas e para nêutrons rápidos de 6 horas. O sistema dosimétrico desenvolvido apresentou sensibilidades a nêutrons térmicos, epitérmicos e rápidos dadas pelos valores (1,46 +/- 0,09) 10 POT.4 traços cm POT.-2 mSv POT.-1, (9 +/- 3) 10² traços cm POT.-2 mSv POT.-1 e (26 +/- 4) traços cm POT.-2 mSv POT.-1 respectivamente. As doses mínimas e máximas detectáveis foram respectivamente 0,002 mSv e 0,6 mSv para nêutrons térmicos, 0,04 mSv e 8 mSv para nêutrons epitérmicos e 1 mSv e 12 mSv para nêutrons rápidos. Tendo em vista as implicações das recomendações do ICRP-60, pode-se concluir que o dosímetro pessoal elaborado neste trabalho apresenta a sensibilidade necessária no caso da monitoração de nêutrons térmicos e epitérmicos, mas que exigiria tempos de integração de doses superiores à mensal no caso da monitoração de nêutrons rápidos.O procedimento proposto para ser realizar a dosimetria de nêutrons é baseado no uso conjugado do dosímetro pessoal elaborado e do espectrômetro de esferas de Bonner enquanto dosímetro de área. / A neutron irradiation facility was designed and built in order to establish a procedure for calibrating neutron monitors and dosimeters. A 185 GBq ANTPOT.241 AmBe source in the air provides neutron doses rates between 9 nSv s POT.-1 and 0,5 muuSv s POT.-1. A calibrated 50 nSv s POT.-1 thermal neutron field is obtained by using a specially designed paraffin block in conjunction with the ANTPOT.241 AmBe source. A Bonner multisphere spectrometer was calibrated, using a procedure based on three methods proposed by international standards. The unfolded ANTPOT.241 AmBe neutron spectrum was determined from Bonner spheres data and resulted in a good agreement with expected values for fluence rate, dose rate and mean energy. A dosimetric system based on the electrochemical etching of CR-39 was developed for personal dosimetry. The dosimeter badge using a (n, alfa) converter, the etching chamber and high frequency power supply were designed and built specially for this project. The electrochemical etching (ECE) parameters used were: a 6N KOH solution, 59°C, 20 kV IND.ppcm POT.-1, 2,0 kHz, 3 hours of ECE for thermal and intermediate neutrons and 6 hours for fast neutrons. The calibration factors for thermal, intermediate and fast neutrons were determined for this personal dosimeter. The sensitivies determined for the developed dosimetric system were (1,46 +/- 0,09)10 POT.4 tracks cm POT.-2 mSv POT.-1 for thermal neutrons, (9 +/- 3)10² tracks cm POT.-2 mSv POT.-1 for intermediate neutrons and (26 +/- 4) tracks cm POT.-2 mSv POT.-1 for fast neutrons. The lower and upper limits of detection were respectively 0,002 mSv and 0,6 mSv for thermal neutrons, 0,04 mSv and 8 mSv for intermediate neutrons and 1 mSv and 12 mSv for fast neutrons. In view of the 1990s ICRP recommendations, it is possible to conclude that the personal dosimeter described in this work is sufficiently sensitive to thermal and intermediate neutrons but fast neutron monitoring at radiological protection level would require an integration period of over a month. The proposed dosimetric procedure is based on the conjugated use of the developed personal dosimeter and the Bonner multisphere spectrometer.
43

Caracterização de bio-óleo da pirólise da palha de cana de açúcar usando fracionamento em sistema pressurizado e cromatografia gasosa mono e bidimensional com detector de espectrometria de massas com analisador quadrupolar

Cunha, Michele Espinosa da January 2013 (has links)
Este trabalho descreve a utilização de GC×GC/qMS para a caracterização de bio-óleo obtido a partir da pirólise de palha de cana-de-açúcar e de suas frações resultantes do fracionamento usando solventes pressurizados. É o primeiro uso desta técnica com analisador quadrupolar para a caracterização de bio-óleo. A GC×GC/qMS aliada a algumas ferramentas computacionais, permitiu a identificação e classificação dos compostos de acordo com diversos fatores como a classe química, o número de átomos de carbono, o número de substituintes na cadeia carbônica, o massa molecular e os picos principais no espectro de massas. Utilizou-se também o sistema de LTPRI (índice de retenção linear com temperatura programada) para a confirmação da identificação de alguns dos compostos no bio-óleo e nas frações. Verificou-se um número total de 331 compostos tentativamente identificados no bio-óleo bruto e destes 166 foram confirmados por identificação LTPRI, em sua maioria compostos polares. A análise quantitativa comprovou que o bio-óleo de palha de cana-de-açúcar estudado é composto majoritariamente por fenóis (2-metilfenol, 3,4-dimetilfenol e 4-metilcatecol), além de aldeidos (4-hidróxibenzaldeído e siringaldeído), os quais após o fracionamento puderam ter suas concentrações determinadas na amostra de forma inequívoca pela técnica de cromatografia gasosa. O passo de fracionamento promoveu uma melhor seletividade dos compostos nas frações, permitindo a identificação de um maior número de compostos, assim como suas quantificações. / This work describes the use of GC×GC/qMS for the characterization of bio-oil from the pyrolysis of sugar cane straw and its fractions using pressurized solvent fractionation. This is the first use of this technique for a bio-oil characterization. The GC×GC/qMS allied to some computational tools, allowed the identification and classification of the compounds according manyfactors as chemical class, number of carbons, number of substituents in the carbonic side chain, molecular weight and main peaks in the mass fragmentation spectra. It was used also the LTPRI (linear-temperature-programmed retention index) system for the confirmation of identification of some of the compounds in the bio-oil and fractions. It was found a total number of 331 compounds tentatively identified in the crude bio-oil and 166 were confirmed by LTPRI identification, mostly polar compounds. The quantitative analysis showed that the bio-oil of sugar cane straw is composed mainly by phenols (Phenol, 2-methyl, Phenol, 3,4-dimethyl and Catechol, 4-methyl) and also by the aldehydes Benzaldehyde (4-hydroxy and Syringaldehyde), which after fractionation might have their concentrations determined in the sample so unequivocal by gas chromatography. The step of fractionation stimulated a better selectivity of the compounds in the fractions, permitting the identification of a larger number of compounds, as well as their concentrations.
44

Fabricação e modelagem de uma nova geometria para espectrometria de mobilidade iônica de tolueno, propanol e água com elevada relação sinal-ruído. / Fabrication and modeling of a new geometry for ion mobility spectrometry of toluene propanol and water with high signal-to-noise ratio.

Moreira, Raphael Garcia 13 April 2018 (has links)
Neste trabalho é apresentada uma nova geometria e os critérios de projeto para dispositivos de espectrometria de mobilidade iônica, com objetivo de aumentar a relação entre sinal e ruído detectados pelos eletrômetros que compõem a região de detecção, quando associado à ionização baseada em descargas elétricas que tipicamente emitem maior interferência eletromagnética em relação a outros tipos de ionização. A geometria e os critérios de projeto foram estabelecidos com o auxílio do simulador de trajetórias iônicas SIMION versão 8.1 e comparada com espectrômetros de mobilidade iônica do estado-da-arte. Os resultados das simulações dos dispositivos foram avaliados por meio dos testes estatísticos não-paramétricos de Iman-Davenport e Holm. O resultado indicou que a geometria proposta apresentou compatibilidade com as melhores características dos espectrômetros atuais com confiança estatística a 95 %. Na sequência a geometria proposta foi simulada, fabricada e testada para detecção dos íons de: tolueno - C7H8 (C5H5+, C6H5+, C7H7+), propanol - C3H8O (CH3+, CH3O+, C2H3+, C2H4O+, C2H5O+, C3H6+, C3H7+, C3H7O+) e água - H2O (H+, HO+, H2+, O+). Os picos de corrente iônica detectada nos eletrômetros indicaram coerência com as trajetórias simuladas para estes conjuntos de íons. Além disso, os resultados experimentais apresentaram um aumento na relação entre sinal e ruído para a nova geometria proposta que foi validada pelo teste de comparação pareada não-paramétrico de Wilcoxon a 95 % de confiança estatística. / In this work, a new geometry and a design criteria for ion mobility spectrometry devices was presented, aiming to increase the signal-to-noise ratio detected by electrodes of the detection region, when associated with ionization based on electrical discharges. The new geometry and the design criteria were established in the SIMION version 8.1 (an ionic trajectory simulator) and compared with the state-of-art ion mobility spectrometers. The results from device simulations were evaluated using the non-parametric statistical test of Iman-Davenport and Holm. The result indicated that the proposed design criteria presented compatibility with the best characteristics of current spectrometers with statistical evidence at 95%. The proposed geometry was simulated, fabricated and tested for the following solvents: toluene - C7H8 (C5H5+, C6H5+, C7H7+), propanol - C3H8O (CH3+, CH3O+, C2H3+, C2H4O+, C2H5O+, C3H6+, C3H7+, C3H7O+) and water - H2O (H+, HO+, H2+, O+). The peaks of ion current detected in the electrometers occurred at approximate positions of the simulated trajectories for these sets of ions. In addition, the experimental data showed an increase in the signal-to-noise ratio for the proposed new geometry that was validated by the test statistic of Wilcoxon signed rank at 95% statistical confidence.
45

Fabricação e modelagem de uma nova geometria para espectrometria de mobilidade iônica de tolueno, propanol e água com elevada relação sinal-ruído. / Fabrication and modeling of a new geometry for ion mobility spectrometry of toluene propanol and water with high signal-to-noise ratio.

Raphael Garcia Moreira 13 April 2018 (has links)
Neste trabalho é apresentada uma nova geometria e os critérios de projeto para dispositivos de espectrometria de mobilidade iônica, com objetivo de aumentar a relação entre sinal e ruído detectados pelos eletrômetros que compõem a região de detecção, quando associado à ionização baseada em descargas elétricas que tipicamente emitem maior interferência eletromagnética em relação a outros tipos de ionização. A geometria e os critérios de projeto foram estabelecidos com o auxílio do simulador de trajetórias iônicas SIMION versão 8.1 e comparada com espectrômetros de mobilidade iônica do estado-da-arte. Os resultados das simulações dos dispositivos foram avaliados por meio dos testes estatísticos não-paramétricos de Iman-Davenport e Holm. O resultado indicou que a geometria proposta apresentou compatibilidade com as melhores características dos espectrômetros atuais com confiança estatística a 95 %. Na sequência a geometria proposta foi simulada, fabricada e testada para detecção dos íons de: tolueno - C7H8 (C5H5+, C6H5+, C7H7+), propanol - C3H8O (CH3+, CH3O+, C2H3+, C2H4O+, C2H5O+, C3H6+, C3H7+, C3H7O+) e água - H2O (H+, HO+, H2+, O+). Os picos de corrente iônica detectada nos eletrômetros indicaram coerência com as trajetórias simuladas para estes conjuntos de íons. Além disso, os resultados experimentais apresentaram um aumento na relação entre sinal e ruído para a nova geometria proposta que foi validada pelo teste de comparação pareada não-paramétrico de Wilcoxon a 95 % de confiança estatística. / In this work, a new geometry and a design criteria for ion mobility spectrometry devices was presented, aiming to increase the signal-to-noise ratio detected by electrodes of the detection region, when associated with ionization based on electrical discharges. The new geometry and the design criteria were established in the SIMION version 8.1 (an ionic trajectory simulator) and compared with the state-of-art ion mobility spectrometers. The results from device simulations were evaluated using the non-parametric statistical test of Iman-Davenport and Holm. The result indicated that the proposed design criteria presented compatibility with the best characteristics of current spectrometers with statistical evidence at 95%. The proposed geometry was simulated, fabricated and tested for the following solvents: toluene - C7H8 (C5H5+, C6H5+, C7H7+), propanol - C3H8O (CH3+, CH3O+, C2H3+, C2H4O+, C2H5O+, C3H6+, C3H7+, C3H7O+) and water - H2O (H+, HO+, H2+, O+). The peaks of ion current detected in the electrometers occurred at approximate positions of the simulated trajectories for these sets of ions. In addition, the experimental data showed an increase in the signal-to-noise ratio for the proposed new geometry that was validated by the test statistic of Wilcoxon signed rank at 95% statistical confidence.
46

Desenvolvimento de um espectrômetro de correlação angular gama-gama perturbada com seis detectores de BaF2 e estudo de interações hiperfinas em composto intermetálico LaMnSi2 / Development of a perturbed gama-gama angular correlation spectrometer with six BaF2 detectors and study of hiperfine interaction in the intermetallic compound LaMnSi2

Domienikan, Claudio 17 November 2016 (has links)
Neste trabalho foi desenvolvido um Espectrômetro de Correlação Angular Gama- Gama Perturbada Diferencial em Tempo (CAP) constituído por seis detectores cintiladores de BaF2, para realização de medidas de interações hiperfinas (campo hiperfino magnético e gradiente de campo elétrico) em diversos materiais e propiciar estudos na área da física da matéria condensada. O espectrômetro desenvolvido possui um sistema de aquisição não convencional em comparação aos demais equipamentos destinados a medidas de CAP. Ao invés do tradicional Analisador Multicanal (MCA), este espectrômetro utiliza um sistema de aquisição de dados constituído, basicamente, por um Conversor Analógico Digital (ADC) rápido, uma placa digital (I/O) convencional e um roteador construído no laboratório de Interações Hiperfinas (LIH) do IPEN. Este versátil e eficiente sistema, controlado por um software também criado no LIH em LabVIEW, permite a geração simultânea de 30 espectros de coincidências γ - γ atrasadas, número superior em comparação aos 12 espectros do antigo espectrômetro de quatro detectores. Além de medidas de linearidade, resolução em tempo e tempo morto, o funcionamento e o desempenho do espectrômetro foram comprovados através de medidas de CAP utilizando os núcleos de prova 111In -> 111Cd e 181Hf -> 181Ta, cujos resultados são bem conhecidos da literatura. Foram feitas medidas de interação quadrupolar do 181Ta em háfnio metálico e do 111Cd em cádmio metálico, e de campo hiperfino magnético do 111Cd e do 181Ta em níquel. Os resultados destas medidas se mostraram em concordância com a literatura. Adicionalmente foram realizadas medidas inéditas de interações hiperfinas magnéticas no composto intermetálico LaMnSi2 utilizando os núcleos de prova 111Cd e 140Ce. As medidas foram realizadas na faixa de temperatura de 10 K a 400K. No caso das medidas utilizando a sonda 111In -> 111Cd, os resultados mostram uma variação do campo magnético com a temperatura que segue a função de Brillouin. Já no caso das medidas com o núcleo de prova 140La -> 140Ce, o resultado apresentou um comportamento anômalo do campo hiperfino em função de temperatura. Os resultados evidenciam uma forte hibridização da banda 4f do Ce com a banda 3d do Mn, fato verificado e estudado em trabalhos anteriores com compostos semelhantes. / In this work a Perturbed gama-gama Angular Correlation (PAC) spectrometer was constructed consisting of six BaF2 scintillator detectors to perform measurements of hyperfine interactions (magnetic hyperfine field and electric field gradient) in different materials to study condensed matter physics. The spectrometer developed has an unconventional acquisition system compared to other equipment for PAC measurements. Instead of a traditional multichannel analyzer (MCA), the spectrometer utilizes a data acquisition system consisting of basically a fast analog to digital converter (ADC), a conventional digital card (I/O) and a router constructed in the hyperfine interactions laboratory (LIH) of IPEN. This versatile and efficient system, controlled by software, also developed in the LIH using LabVIEW, allows simultaneous generation of 30 delayed γ - γ coincidence spectra compared to 12 spectra in the old 4 detector spectrometer in our laboratory. In addition to the tests of system linearity, time resolution and dead time, the operational performance of this spectrometer was demonstrated by PAC measurements using 111In -> 111Cd and 181Hf -> 181Ta nuclear probes, for which the results are well known from the literature. The quadrupole interaction of 181Ta in metallic hafnium, and 111Cd in metallic cadmium, and magnetic hyperfine field of 111Cd in nickel, were measured and the results are in agreement with the literature. Additionally the measurements were carried out, with the new spectrometer, to study the hyperfine field in the intermetallic compound LaMnSi2 using 111Cd and 140Ce nuclear probes. The measurements were carried out in the temperature range from 10 K to 400 K. While the temperature dependence of hyperfine field measured with 111In -> 111Cd probe, follows the Brillouin function the behaviour of the hyperfine field measured with 140La -> 140Ce is anomalous. This behavior has been explained in terms of a strong hybridization of 4f band of Ce with the 3d band of Mn, a fact verified in previous studies with similar compounds.
47

Desenvolvimento de um espectrômetro de correlação angular gama-gama perturbada com seis detectores de BaF2 e estudo de interações hiperfinas em composto intermetálico LaMnSi2 / Development of a perturbed gama-gama angular correlation spectrometer with six BaF2 detectors and study of hiperfine interaction in the intermetallic compound LaMnSi2

Claudio Domienikan 17 November 2016 (has links)
Neste trabalho foi desenvolvido um Espectrômetro de Correlação Angular Gama- Gama Perturbada Diferencial em Tempo (CAP) constituído por seis detectores cintiladores de BaF2, para realização de medidas de interações hiperfinas (campo hiperfino magnético e gradiente de campo elétrico) em diversos materiais e propiciar estudos na área da física da matéria condensada. O espectrômetro desenvolvido possui um sistema de aquisição não convencional em comparação aos demais equipamentos destinados a medidas de CAP. Ao invés do tradicional Analisador Multicanal (MCA), este espectrômetro utiliza um sistema de aquisição de dados constituído, basicamente, por um Conversor Analógico Digital (ADC) rápido, uma placa digital (I/O) convencional e um roteador construído no laboratório de Interações Hiperfinas (LIH) do IPEN. Este versátil e eficiente sistema, controlado por um software também criado no LIH em LabVIEW, permite a geração simultânea de 30 espectros de coincidências γ - γ atrasadas, número superior em comparação aos 12 espectros do antigo espectrômetro de quatro detectores. Além de medidas de linearidade, resolução em tempo e tempo morto, o funcionamento e o desempenho do espectrômetro foram comprovados através de medidas de CAP utilizando os núcleos de prova 111In -> 111Cd e 181Hf -> 181Ta, cujos resultados são bem conhecidos da literatura. Foram feitas medidas de interação quadrupolar do 181Ta em háfnio metálico e do 111Cd em cádmio metálico, e de campo hiperfino magnético do 111Cd e do 181Ta em níquel. Os resultados destas medidas se mostraram em concordância com a literatura. Adicionalmente foram realizadas medidas inéditas de interações hiperfinas magnéticas no composto intermetálico LaMnSi2 utilizando os núcleos de prova 111Cd e 140Ce. As medidas foram realizadas na faixa de temperatura de 10 K a 400K. No caso das medidas utilizando a sonda 111In -> 111Cd, os resultados mostram uma variação do campo magnético com a temperatura que segue a função de Brillouin. Já no caso das medidas com o núcleo de prova 140La -> 140Ce, o resultado apresentou um comportamento anômalo do campo hiperfino em função de temperatura. Os resultados evidenciam uma forte hibridização da banda 4f do Ce com a banda 3d do Mn, fato verificado e estudado em trabalhos anteriores com compostos semelhantes. / In this work a Perturbed gama-gama Angular Correlation (PAC) spectrometer was constructed consisting of six BaF2 scintillator detectors to perform measurements of hyperfine interactions (magnetic hyperfine field and electric field gradient) in different materials to study condensed matter physics. The spectrometer developed has an unconventional acquisition system compared to other equipment for PAC measurements. Instead of a traditional multichannel analyzer (MCA), the spectrometer utilizes a data acquisition system consisting of basically a fast analog to digital converter (ADC), a conventional digital card (I/O) and a router constructed in the hyperfine interactions laboratory (LIH) of IPEN. This versatile and efficient system, controlled by software, also developed in the LIH using LabVIEW, allows simultaneous generation of 30 delayed γ - γ coincidence spectra compared to 12 spectra in the old 4 detector spectrometer in our laboratory. In addition to the tests of system linearity, time resolution and dead time, the operational performance of this spectrometer was demonstrated by PAC measurements using 111In -> 111Cd and 181Hf -> 181Ta nuclear probes, for which the results are well known from the literature. The quadrupole interaction of 181Ta in metallic hafnium, and 111Cd in metallic cadmium, and magnetic hyperfine field of 111Cd in nickel, were measured and the results are in agreement with the literature. Additionally the measurements were carried out, with the new spectrometer, to study the hyperfine field in the intermetallic compound LaMnSi2 using 111Cd and 140Ce nuclear probes. The measurements were carried out in the temperature range from 10 K to 400 K. While the temperature dependence of hyperfine field measured with 111In -> 111Cd probe, follows the Brillouin function the behaviour of the hyperfine field measured with 140La -> 140Ce is anomalous. This behavior has been explained in terms of a strong hybridization of 4f band of Ce with the 3d band of Mn, a fact verified in previous studies with similar compounds.
48

Microextração em fase sólida no modo headspace aplicada ao estudo de substâncias voláteis de plantas infestadas por galhas foliares entomógenas

Damasceno, Flaviana Cardoso January 2007 (has links)
Neste trabalho foi verificada a eficiência da HS-SPME associada à GC/qMS como ferramenta capaz de detectar alterações no perfil de compostos voláteis de Schinus polygamus e Baccharis spicata. Estas alterações são provocadas por insetos herbívoros (cecidógenos) que utilizam as folhas destas plantas como local para se alimentarem e se reproduzirem e, como conseqüência, produzem alterações no tecido vegetal (galhas). Para este propósito foi usado, como fase extratora, o filme polimérico DVB-CAR-PDMS, que apresenta alta capacidade de extração. Na S. polygamus, tanto folhas sadias, como galhas apresentaram grande quantidade de n-heptano (> 38,2 %) e n-nonano (> 24,4 %), sendo que este não foi detectado no óleo hidrodestilado de folhas da mesma amostra. Nas galhas também foi constatada a presença de alguns mono- e sesquiterpenos não detectados nas folhas, sendo o a-pineno (17,6 %), um dos compostos majoritários. Foi também observado um acréscimo significativo na concentração do limoneno. Os compostos majoritários no headspace das folhas de B. spicata foram: 1-undeceno (17,8 %), limoneno (15,3 %), b-pineno (13,5 %), (E)-cariofileno (12,8 %) e g-muroleno (11,4 %), enquanto que nas galhas, os compostos majoritários foram o a-pineno (40,9 %) e o limoneno (19,1 %). O 1-undeceno não foi detectado no óleo hidrodestilado de folhas desta planta, enquanto que o espatulenol foi o composto majoritário deste óleo (34,3%), encontrando-se em baixas concentrações nos voláteis extraídos por HS-SPME. As diferenças constatadas na composição dos VOC de folhas e galhas nas espécies S. polygamus e B. spicata podem ser um fator indicativo de que a presença do cecidógeno estimula a biossíntese de alguns compostos, que podem apresentar algum tipo de função infoquímica. Evidências de diferenças qualitativas entre o óleo hidrodestilado das folhas sadias e o perfil dos compostos voláteis do headspace das mesmas também são um indicativo de que o emprego de temperaturas amenas na HS-SPME propicia a obtenção de um perfil de compostos voláteis mais próximo daquele da planta in vivo. O acesso a estas diferenças (qualitativas e quantitativas) só foi possível através do emprego da HS-SPME, o que evidencia o potencial desta técnica como ferramenta investigativa para compostos infoquímicos, abrindo horizontes para futuras pesquisas. / HS-SPME coupled to GC/qMS was employed in this work as an efficient tool to verify differences in the volatile compounds composition of Schinus polygamus and Baccharis spicata leaves and galls. Plant volatile composition may be changed when herbivore insects (cecidógenos) use leaves as a site for reproduction and for feeding purposes. The action of those insects may resulting changes in plant tissue, which are called galls. The triple layer DVB-CAR-PDMS fiber was employed as sorbing phase, in order to achieve high efficiency in the extraction process. Galled and ungalled S. polygamus leaves presented high amount of n-heptane (> 38,2 %) and n-nonane (> 24,4 %), while n-heptane was not detected in the hydrodistilled oil of leaves of the same sample. The presence of a-pinene was observed only in galls, along with some other mono- and sesquiterpenes. Also, the amount of limonene was higher in galls than in ungalled leaves. Major compounds in the headspace of B. spicata leaves were: 1-undecene (17,8 %), limonene (15,3 %), b-pinene (13,5 %), (E)-caryophyllene (12,8 %) e g-muurolene (11,4 %), while in galls a-pinene (40,9 %) and limonene (19,1 %) were present in higher concentrations. One-undecene was not detected in the hydrodistilled oil of the leaves of this plant and spathulenol was the major compound of this oil (34,3%), being present in low concentrations in the chromatographic profile of HS-SPME. Differences found in the VOC composition of galls and ungalled leaves of S. polygamus e B. spicata may be an evidence of the cecidogene presence, which might stimulate the biosynthesis of some infochemical compounds. Qualitative differences between hydrodistilled oil and headspace chromatographic profile of the same sample indicates that HS-SPME mild temperatures provide a volatile compounds profile closer to that of in vivo plant. Approaching qualitative and quantitative differences in plant volatile compounds profile was made possible only through the use of HS-SPME. This fact highlights the potential of this technique as a research tool for infochemical compounds studies, and opens new horizons for future investigations of distinct plants.
49

Microextração em fase sólida no modo headspace aplicada ao estudo de substâncias voláteis de plantas infestadas por galhas foliares entomógenas

Damasceno, Flaviana Cardoso January 2007 (has links)
Neste trabalho foi verificada a eficiência da HS-SPME associada à GC/qMS como ferramenta capaz de detectar alterações no perfil de compostos voláteis de Schinus polygamus e Baccharis spicata. Estas alterações são provocadas por insetos herbívoros (cecidógenos) que utilizam as folhas destas plantas como local para se alimentarem e se reproduzirem e, como conseqüência, produzem alterações no tecido vegetal (galhas). Para este propósito foi usado, como fase extratora, o filme polimérico DVB-CAR-PDMS, que apresenta alta capacidade de extração. Na S. polygamus, tanto folhas sadias, como galhas apresentaram grande quantidade de n-heptano (> 38,2 %) e n-nonano (> 24,4 %), sendo que este não foi detectado no óleo hidrodestilado de folhas da mesma amostra. Nas galhas também foi constatada a presença de alguns mono- e sesquiterpenos não detectados nas folhas, sendo o a-pineno (17,6 %), um dos compostos majoritários. Foi também observado um acréscimo significativo na concentração do limoneno. Os compostos majoritários no headspace das folhas de B. spicata foram: 1-undeceno (17,8 %), limoneno (15,3 %), b-pineno (13,5 %), (E)-cariofileno (12,8 %) e g-muroleno (11,4 %), enquanto que nas galhas, os compostos majoritários foram o a-pineno (40,9 %) e o limoneno (19,1 %). O 1-undeceno não foi detectado no óleo hidrodestilado de folhas desta planta, enquanto que o espatulenol foi o composto majoritário deste óleo (34,3%), encontrando-se em baixas concentrações nos voláteis extraídos por HS-SPME. As diferenças constatadas na composição dos VOC de folhas e galhas nas espécies S. polygamus e B. spicata podem ser um fator indicativo de que a presença do cecidógeno estimula a biossíntese de alguns compostos, que podem apresentar algum tipo de função infoquímica. Evidências de diferenças qualitativas entre o óleo hidrodestilado das folhas sadias e o perfil dos compostos voláteis do headspace das mesmas também são um indicativo de que o emprego de temperaturas amenas na HS-SPME propicia a obtenção de um perfil de compostos voláteis mais próximo daquele da planta in vivo. O acesso a estas diferenças (qualitativas e quantitativas) só foi possível através do emprego da HS-SPME, o que evidencia o potencial desta técnica como ferramenta investigativa para compostos infoquímicos, abrindo horizontes para futuras pesquisas. / HS-SPME coupled to GC/qMS was employed in this work as an efficient tool to verify differences in the volatile compounds composition of Schinus polygamus and Baccharis spicata leaves and galls. Plant volatile composition may be changed when herbivore insects (cecidógenos) use leaves as a site for reproduction and for feeding purposes. The action of those insects may resulting changes in plant tissue, which are called galls. The triple layer DVB-CAR-PDMS fiber was employed as sorbing phase, in order to achieve high efficiency in the extraction process. Galled and ungalled S. polygamus leaves presented high amount of n-heptane (> 38,2 %) and n-nonane (> 24,4 %), while n-heptane was not detected in the hydrodistilled oil of leaves of the same sample. The presence of a-pinene was observed only in galls, along with some other mono- and sesquiterpenes. Also, the amount of limonene was higher in galls than in ungalled leaves. Major compounds in the headspace of B. spicata leaves were: 1-undecene (17,8 %), limonene (15,3 %), b-pinene (13,5 %), (E)-caryophyllene (12,8 %) e g-muurolene (11,4 %), while in galls a-pinene (40,9 %) and limonene (19,1 %) were present in higher concentrations. One-undecene was not detected in the hydrodistilled oil of the leaves of this plant and spathulenol was the major compound of this oil (34,3%), being present in low concentrations in the chromatographic profile of HS-SPME. Differences found in the VOC composition of galls and ungalled leaves of S. polygamus e B. spicata may be an evidence of the cecidogene presence, which might stimulate the biosynthesis of some infochemical compounds. Qualitative differences between hydrodistilled oil and headspace chromatographic profile of the same sample indicates that HS-SPME mild temperatures provide a volatile compounds profile closer to that of in vivo plant. Approaching qualitative and quantitative differences in plant volatile compounds profile was made possible only through the use of HS-SPME. This fact highlights the potential of this technique as a research tool for infochemical compounds studies, and opens new horizons for future investigations of distinct plants.
50

Microextração em fase sólida no modo headspace aplicada ao estudo de substâncias voláteis de plantas infestadas por galhas foliares entomógenas

Damasceno, Flaviana Cardoso January 2007 (has links)
Neste trabalho foi verificada a eficiência da HS-SPME associada à GC/qMS como ferramenta capaz de detectar alterações no perfil de compostos voláteis de Schinus polygamus e Baccharis spicata. Estas alterações são provocadas por insetos herbívoros (cecidógenos) que utilizam as folhas destas plantas como local para se alimentarem e se reproduzirem e, como conseqüência, produzem alterações no tecido vegetal (galhas). Para este propósito foi usado, como fase extratora, o filme polimérico DVB-CAR-PDMS, que apresenta alta capacidade de extração. Na S. polygamus, tanto folhas sadias, como galhas apresentaram grande quantidade de n-heptano (> 38,2 %) e n-nonano (> 24,4 %), sendo que este não foi detectado no óleo hidrodestilado de folhas da mesma amostra. Nas galhas também foi constatada a presença de alguns mono- e sesquiterpenos não detectados nas folhas, sendo o a-pineno (17,6 %), um dos compostos majoritários. Foi também observado um acréscimo significativo na concentração do limoneno. Os compostos majoritários no headspace das folhas de B. spicata foram: 1-undeceno (17,8 %), limoneno (15,3 %), b-pineno (13,5 %), (E)-cariofileno (12,8 %) e g-muroleno (11,4 %), enquanto que nas galhas, os compostos majoritários foram o a-pineno (40,9 %) e o limoneno (19,1 %). O 1-undeceno não foi detectado no óleo hidrodestilado de folhas desta planta, enquanto que o espatulenol foi o composto majoritário deste óleo (34,3%), encontrando-se em baixas concentrações nos voláteis extraídos por HS-SPME. As diferenças constatadas na composição dos VOC de folhas e galhas nas espécies S. polygamus e B. spicata podem ser um fator indicativo de que a presença do cecidógeno estimula a biossíntese de alguns compostos, que podem apresentar algum tipo de função infoquímica. Evidências de diferenças qualitativas entre o óleo hidrodestilado das folhas sadias e o perfil dos compostos voláteis do headspace das mesmas também são um indicativo de que o emprego de temperaturas amenas na HS-SPME propicia a obtenção de um perfil de compostos voláteis mais próximo daquele da planta in vivo. O acesso a estas diferenças (qualitativas e quantitativas) só foi possível através do emprego da HS-SPME, o que evidencia o potencial desta técnica como ferramenta investigativa para compostos infoquímicos, abrindo horizontes para futuras pesquisas. / HS-SPME coupled to GC/qMS was employed in this work as an efficient tool to verify differences in the volatile compounds composition of Schinus polygamus and Baccharis spicata leaves and galls. Plant volatile composition may be changed when herbivore insects (cecidógenos) use leaves as a site for reproduction and for feeding purposes. The action of those insects may resulting changes in plant tissue, which are called galls. The triple layer DVB-CAR-PDMS fiber was employed as sorbing phase, in order to achieve high efficiency in the extraction process. Galled and ungalled S. polygamus leaves presented high amount of n-heptane (> 38,2 %) and n-nonane (> 24,4 %), while n-heptane was not detected in the hydrodistilled oil of leaves of the same sample. The presence of a-pinene was observed only in galls, along with some other mono- and sesquiterpenes. Also, the amount of limonene was higher in galls than in ungalled leaves. Major compounds in the headspace of B. spicata leaves were: 1-undecene (17,8 %), limonene (15,3 %), b-pinene (13,5 %), (E)-caryophyllene (12,8 %) e g-muurolene (11,4 %), while in galls a-pinene (40,9 %) and limonene (19,1 %) were present in higher concentrations. One-undecene was not detected in the hydrodistilled oil of the leaves of this plant and spathulenol was the major compound of this oil (34,3%), being present in low concentrations in the chromatographic profile of HS-SPME. Differences found in the VOC composition of galls and ungalled leaves of S. polygamus e B. spicata may be an evidence of the cecidogene presence, which might stimulate the biosynthesis of some infochemical compounds. Qualitative differences between hydrodistilled oil and headspace chromatographic profile of the same sample indicates that HS-SPME mild temperatures provide a volatile compounds profile closer to that of in vivo plant. Approaching qualitative and quantitative differences in plant volatile compounds profile was made possible only through the use of HS-SPME. This fact highlights the potential of this technique as a research tool for infochemical compounds studies, and opens new horizons for future investigations of distinct plants.

Page generated in 0.0918 seconds