• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 4
  • Tagged with
  • 15
  • 8
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estimation of global radon exhalation rate distribution

Goto, Masayoshi, Moriizumi, Jun, Yamazawa, Hiromi, lida, Takao, Zhuo, Weihai 08 1900 (has links)
No description available.
2

Humming, nitric oxide and paranasal sinus ventilation /

Maniscalco, Mauro, January 2006 (has links)
Diss. (sammanfattning) Stockholm : Karol. inst., 2006. / Härtill 5 uppsatser.
3

Avaliação da radioatividade natural em algumas rochas graníticas do Estado do Paraná e sua utilização na construção civil / Evaluation of natural radioactivity in some granitic rocks in the state of Paraná and its use in civil construction

Ademar de Oliveira Ferreira 25 March 2013 (has links)
Os radionuclídeos naturais de origem primordial, ou terrestres, são encontrados em quantidades variadas em todo meio ambiente. Nas residências, um importante incremento de dose (INDOOR), é devido aos materiais de construção, que contribuem tanto com a dose externa gama, proveniente das séries do 238U, 235U e 232Th e do radionuclídeo isolado 40K, quanto com a dose interna que é devida principalmente à inalação do 222Rn. Uma vez que rochas graníticas são amplamente utilizadas como materiais de construção, tanto estruturais como de revestimento, estas podem tornar-se uma importante fonte de dose, dependendo das concentrações de radioatividade que apresentem, e da forma e quantidade que são aplicadas nas construções. Neste trabalho foi gerado um banco de dados para rochas graníticas do escudo cristalino paranaense (principalmente da Região Metropolitana de Curitiba, RMC), que são utilizadas na construção civil avaliando em termos de proteção radiológica o incremento da dose, externa e interna, causada pela utilização destes materiais. Também foram estudadas as possíveis correlações entre a concentração de atividade de 226Ra, taxa de exalação de 222Rn, densidade, porosidade e composição química (teor de óxidos constituintes) nestas amostras. A dose externa foi avaliada por meio da técnica de espectrometria gama com detector de germânio hiperpuro, onde as concentrações de atividade dos radionuclídeos 226Ra, 232Th e 40K são os parâmetros utilizados em modelos dosimétricos (Índices Dosimétricos), os quais estabelecem limites máximos permitidos de acordo com forma, quantidade e aplicação do material de construção. Para o cálculo da dose efetiva anual externa foi adotado o modelo de sala com dimensões 4 m x 5 m x 2,8 m e todas as paredes são revestidas internamente com granitos de espessura de 2 cm e considerando o tempo de exposição anual de 7000 h, conforme sugerido pela Comissão Européia de Proteção Radiológica para materiais de revestimento interno supercial. A exposição interna foi avaliada a partir da concentração de radônio no ar da sala modelo, simulada a partir do valor da taxa de exalação supercial de 222Rn. A taxa de exalação foi determinada pela técnica de detecção passiva utilizando detectores sólidos de traços nucleares (CR-39) por meio da técnica do recipiente selado, considerando taxa de ventilação de 0,5 h-1 e tempo de exposição anual de 7000 h . Os resultados destes estudos mostram que o incremento da dose efetiva anual externa variou de (62 ± 3) μSv.a-1 a (138 ± 1) μSv.a-1 e o incremento da dose efetiva anual interna variou de (0,39 ± 0,04) μSv.a-1 a (70 ± 4) μSv.a-1. Estes valores estão abaixo do limite máximo de 1 mSv.a-1 sugerido pela Comissão Européia de Proteção Radiológica, portanto os granitos avaliados neste trabalho podem ser utilizados sem implicações radiológicas desde que obedecido o cenário descrito. Os valores obtidos para a contribuição devida à dose interna variaram de 1 % a 78 % dos valores obtidos para a respectiva dose externa, mostrando que a contribuição do radônio varia fortemente com o tipo da rocha. Os resultados das correlações entre taxa de exalação supercial de 222Rn, concentração de atividade de 226Ra, densidade, porosidade e principais óxidos componentes das amostras, mostraram que, em termos de inuência na fração de emanação do radônio, o parâmetro mais importante é a densidade, devido a baixa porosidade e a semelhança em termos de composição química entre as amostras. / Primordial, or terrestrial natural radionuclides, are found in dierent amounts in the environment. In dwellings, an important dose increment is due to building materials, which contribute for both the external gamma dose from the radionuclides of the 238U, 235U and 232Th series and the natural 40K and the internal dose, due mainly to 222Rn inhalation. Once granitic rocks are widely used both as construction materials or structural flooring, those rocks can become an important dose source, depending on the content of concentrations of radioactivity, and the construction application. In this work, a database for granitic rocks of the crystalline shield of Paraná (mainly in the Metropolitan Region of Curitiba, RMC), used in civil construction, was generated, evaluating in terms of radiological protection the external and internal dose increments, caused by the use of these materials. Also, possible correlations between the 226Ra activity concentration, the 222Rn exhalation rate, density, porosity and chemical composition (oxide content) in these samples had been studied. The external dose was assessed by gamma-ray spectrometry with High-Purity Germanium detectors, where the activity concentration of the radionuclides 232Th, 226Ra and 40K are the parameters used in dosimetric models (Dosimetric Indexes), which established limits in accordance with the form, amount and application of material of construction. For the calculation of the annual eective external dose it was assumed a room model with dimensions of 4 m x 5 m x 2.8 m and all walls internally covered with 2 cm thickness of granite and an annual exposure time of 7000 h as suggested by the European Commission of Radiological Protection for internal supercial coating materials. The internal exposure was assessed from the radon concentration in the air of the room model, simulated from the supercial exhalation rate of 222Rn. The exhalation rate was determined by the passive detection technique with the Solid State Nuclear Track Detectors (CR-39) and the sealed can technique, assuming a ventilation rate of 0.5 h-1 and an annual exposure time of 7000 h. The results for this studies show that the annual eective dose ranged from (62 ± 3) μSv.y1 to (138 ± 1) μSv.y-1 and the internal annual eective dose ranged from (0,39 ± 0,04) μSv.y-1 to (70 ± 4) μSv.y-1. These values are below the maximum limit of 1 mSv.y-1 suggested by the European Commission of Radiological Protection, meaning that the granitic rocks evaluated can be used without radiological implications since the considered scenario is obeyed. The values obtained for the contribution due to the internal dose ranged from 1 % to 78 % of the values obtained for the respective external dose showing the radon contribution varies strongly with the rock type. The results of the correlations between 222Rn supercial exhalation rate, 226Ra activity concentration, density, porosity and major oxides of the samples, showed that, in terms of inuence in the emanation fraction of radon, the most important parameter is the density, due to low porosity and similarity in terms of chemical composition amid the studied samples.
4

Avaliação da radioatividade natural em algumas rochas graníticas do Estado do Paraná e sua utilização na construção civil / Evaluation of natural radioactivity in some granitic rocks in the state of Paraná and its use in civil construction

Ferreira, Ademar de Oliveira 25 March 2013 (has links)
Os radionuclídeos naturais de origem primordial, ou terrestres, são encontrados em quantidades variadas em todo meio ambiente. Nas residências, um importante incremento de dose (INDOOR), é devido aos materiais de construção, que contribuem tanto com a dose externa gama, proveniente das séries do 238U, 235U e 232Th e do radionuclídeo isolado 40K, quanto com a dose interna que é devida principalmente à inalação do 222Rn. Uma vez que rochas graníticas são amplamente utilizadas como materiais de construção, tanto estruturais como de revestimento, estas podem tornar-se uma importante fonte de dose, dependendo das concentrações de radioatividade que apresentem, e da forma e quantidade que são aplicadas nas construções. Neste trabalho foi gerado um banco de dados para rochas graníticas do escudo cristalino paranaense (principalmente da Região Metropolitana de Curitiba, RMC), que são utilizadas na construção civil avaliando em termos de proteção radiológica o incremento da dose, externa e interna, causada pela utilização destes materiais. Também foram estudadas as possíveis correlações entre a concentração de atividade de 226Ra, taxa de exalação de 222Rn, densidade, porosidade e composição química (teor de óxidos constituintes) nestas amostras. A dose externa foi avaliada por meio da técnica de espectrometria gama com detector de germânio hiperpuro, onde as concentrações de atividade dos radionuclídeos 226Ra, 232Th e 40K são os parâmetros utilizados em modelos dosimétricos (Índices Dosimétricos), os quais estabelecem limites máximos permitidos de acordo com forma, quantidade e aplicação do material de construção. Para o cálculo da dose efetiva anual externa foi adotado o modelo de sala com dimensões 4 m x 5 m x 2,8 m e todas as paredes são revestidas internamente com granitos de espessura de 2 cm e considerando o tempo de exposição anual de 7000 h, conforme sugerido pela Comissão Européia de Proteção Radiológica para materiais de revestimento interno supercial. A exposição interna foi avaliada a partir da concentração de radônio no ar da sala modelo, simulada a partir do valor da taxa de exalação supercial de 222Rn. A taxa de exalação foi determinada pela técnica de detecção passiva utilizando detectores sólidos de traços nucleares (CR-39) por meio da técnica do recipiente selado, considerando taxa de ventilação de 0,5 h-1 e tempo de exposição anual de 7000 h . Os resultados destes estudos mostram que o incremento da dose efetiva anual externa variou de (62 ± 3) μSv.a-1 a (138 ± 1) μSv.a-1 e o incremento da dose efetiva anual interna variou de (0,39 ± 0,04) μSv.a-1 a (70 ± 4) μSv.a-1. Estes valores estão abaixo do limite máximo de 1 mSv.a-1 sugerido pela Comissão Européia de Proteção Radiológica, portanto os granitos avaliados neste trabalho podem ser utilizados sem implicações radiológicas desde que obedecido o cenário descrito. Os valores obtidos para a contribuição devida à dose interna variaram de 1 % a 78 % dos valores obtidos para a respectiva dose externa, mostrando que a contribuição do radônio varia fortemente com o tipo da rocha. Os resultados das correlações entre taxa de exalação supercial de 222Rn, concentração de atividade de 226Ra, densidade, porosidade e principais óxidos componentes das amostras, mostraram que, em termos de inuência na fração de emanação do radônio, o parâmetro mais importante é a densidade, devido a baixa porosidade e a semelhança em termos de composição química entre as amostras. / Primordial, or terrestrial natural radionuclides, are found in dierent amounts in the environment. In dwellings, an important dose increment is due to building materials, which contribute for both the external gamma dose from the radionuclides of the 238U, 235U and 232Th series and the natural 40K and the internal dose, due mainly to 222Rn inhalation. Once granitic rocks are widely used both as construction materials or structural flooring, those rocks can become an important dose source, depending on the content of concentrations of radioactivity, and the construction application. In this work, a database for granitic rocks of the crystalline shield of Paraná (mainly in the Metropolitan Region of Curitiba, RMC), used in civil construction, was generated, evaluating in terms of radiological protection the external and internal dose increments, caused by the use of these materials. Also, possible correlations between the 226Ra activity concentration, the 222Rn exhalation rate, density, porosity and chemical composition (oxide content) in these samples had been studied. The external dose was assessed by gamma-ray spectrometry with High-Purity Germanium detectors, where the activity concentration of the radionuclides 232Th, 226Ra and 40K are the parameters used in dosimetric models (Dosimetric Indexes), which established limits in accordance with the form, amount and application of material of construction. For the calculation of the annual eective external dose it was assumed a room model with dimensions of 4 m x 5 m x 2.8 m and all walls internally covered with 2 cm thickness of granite and an annual exposure time of 7000 h as suggested by the European Commission of Radiological Protection for internal supercial coating materials. The internal exposure was assessed from the radon concentration in the air of the room model, simulated from the supercial exhalation rate of 222Rn. The exhalation rate was determined by the passive detection technique with the Solid State Nuclear Track Detectors (CR-39) and the sealed can technique, assuming a ventilation rate of 0.5 h-1 and an annual exposure time of 7000 h. The results for this studies show that the annual eective dose ranged from (62 ± 3) μSv.y1 to (138 ± 1) μSv.y-1 and the internal annual eective dose ranged from (0,39 ± 0,04) μSv.y-1 to (70 ± 4) μSv.y-1. These values are below the maximum limit of 1 mSv.y-1 suggested by the European Commission of Radiological Protection, meaning that the granitic rocks evaluated can be used without radiological implications since the considered scenario is obeyed. The values obtained for the contribution due to the internal dose ranged from 1 % to 78 % of the values obtained for the respective external dose showing the radon contribution varies strongly with the rock type. The results of the correlations between 222Rn supercial exhalation rate, 226Ra activity concentration, density, porosity and major oxides of the samples, showed that, in terms of inuence in the emanation fraction of radon, the most important parameter is the density, due to low porosity and similarity in terms of chemical composition amid the studied samples.
5

Role of the dorsal periaqueductal gray activation in the neural control of breathing

Zhang, Weirong, January 2004 (has links)
Thesis (Ph.D.)--University of Florida, 2004. / Typescript. Title from title page of source document. Document formatted into pages; contains 127 pages. Includes Vita. Includes bibliographical references.
6

Measurement of nerve growth factor in induced sputum and exhaled breath condensate

Nwiloh, Victor Maduabuchi. January 2006 (has links)
Thesis (M.A.)--University of South Florida, 2006. / Title from PDF of title page. Document formatted into pages; contains 68 pages. Includes bibliographical references.
7

Radônio em área de extração de carvão mineral no município de Figueira (PR) / Radon in coal mining area in the county of Figueira (PR)

Salim, Leonardo Alfredo [UNESP] 02 May 2018 (has links)
Submitted by LEONARDO ALFREDO SALIM null (leonardosalim_las@hotmail.com) on 2018-06-27T16:08:53Z No. of bitstreams: 1 Tese Leonardo Alfredo Salim.pdf: 12084411 bytes, checksum: 4e4df6683eab7d6125b71ecc8e629d94 (MD5) / Approved for entry into archive by Adriana Aparecida Puerta null (dripuerta@rc.unesp.br) on 2018-06-28T12:11:24Z (GMT) No. of bitstreams: 1 salim_la_me_rcla.pdf: 11907717 bytes, checksum: 326a51071a02d7874baae0361ba36f01 (MD5) / Made available in DSpace on 2018-06-28T12:11:24Z (GMT). No. of bitstreams: 1 salim_la_me_rcla.pdf: 11907717 bytes, checksum: 326a51071a02d7874baae0361ba36f01 (MD5) Previous issue date: 2018-05-02 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O gás radônio, resultado do decaimento radioativo do 238U e 232Th, é motivo de grande preocupação para o homem. Ele é uma das mais importantes fontes de radiação ionizante de origem natural que as pessoas estão expostas, sendo considerado pela OMS (Organização Mundial da Saúde) como o segundo maior causador de câncer de pulmão. O carvão mineral como qualquer outro combustível fóssil está associado a materiais radioativos naturais, devido principalmente ao seu conteúdo de 238U e 232Th. Para a compreensão do comportamento do gás radônio em área de mineração de carvão e determinar o grau de exposição das pessoas ao gás nesta área, foram determinadas a taxa de exalação de radônio de amostras de carvão, cinza, siltito e tufo vulcânico coletadas na mina Amado Simões PI-08 (Companhia Carbonífera do Cambuí), em Figueira (PR), a concentração de radônio no ar do interior da mina e a concentração de radônio, parâmetros físicos e químicos dos solos próximos à mina. As taxas de exalações foram obtidas por curvas experimentais da concentração de radônio em função do tempo, e variaram de 0,064 a 0,717 Bq/kg.h. Observou-se que o gás radônio entrou em equilíbrio radioativo após 180 horas de análise. A concentrações de radônio dissolvido no ar do interior da mina variaram de 7,2 a 770,5 Bq/m³, observou-se que o radônio tem maior escape das rochas por fraturas presentes nas frentes de lavra e que maior taxa de exalação vem das rochas encaixantes, remetendo em um problema radiológico à área de descarte. A concentrações de radônio nas amostras de solo variaram de 0,04 a 276,48 (kBq/m³), a qual obteve correlação com a concentração de U, que variou de 0,43 a 8,46 ppm. Observou-se a tendência do radônio se acumular em ambientes com maior concentração de urânio, úmidos, aluminosos, argilosos e com presença de matéria orgânica. / Radon gas, the result of the radioactive decay of 238U and 232Th, is a matter of great concern to man. It is one of the most important sources of naturally occurring ionizing radiation that people are exposed to and is considered by the World Health Organization (WHO) to be the second largest cause of lung cancer. Mineral coal like any other fossil fuel is associated with natural radioactive materials, mainly due to its content of 238U and 232Th. In order to understand the behavior of the radon gas in the coal mining area and determine the degree of exposure of the people to the gas in this area, the radon exhalation rate of samples of coal, ash, silt, and volcanic tuff collected at the Amado mine Simões PI-08 (Companhia Carbonífera do Cambuí), in Figueira (PR), the radon concentration in the air inside the mine and the radon concentration, physical and chemical parameters of the soils near the mine. The exhalation rates were obtained by experimental curves of the radon concentration as a function of time, and ranged from 0.064 to 0.717 Bq / kg.h. It was observed that the radon gas entered into radioactive equilibrium after 180 hours of analysis. The concentrations of radon dissolved in the air inside the mine varied from 7.2 to 770.5 Bq / m³, it was observed that the radon has greater escape of the rocks by fractures present in the mining fronts and that higher exhalation rate comes from encasing rocks, sending in a radiological problem to the area of discard. The concentrations of radon in the soil samples ranged from 0.04 to 276.48 (kBq / m³), which correlated with the U concentration, which ranged from 0.43 to 8.46 ppm. It was observed the tendency of radon to accumulate in environments with higher concentration of uranium, humid, aluminous, clayey and with presence of organic matter. / CNPq: 142378/2017-8.
8

Estudo da exalação de randônio em placas e tijolos de fosfogesso de diferentes procedências / Study of radon exhalation from phosphogypsum plates and blocks from different origins

COSTA, LUCAS J.P. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:31Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:57Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
9

Estudo da exalação de randônio em placas e tijolos de fosfogesso de diferentes procedências / Study of radon exhalation from phosphogypsum plates and blocks from different origins

COSTA, LUCAS J.P. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:31Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:57Z (GMT). No. of bitstreams: 0 / O fosfogesso é um resíduo da indústria de fertilizantes fosfatados que concentra radionuclídeos naturais. Neste trabalho foi estudada a taxa de exalação de 222Rn em placas e tijolos de fosfogesso, visando sua utilização na construção de residências. Para tanto, foram determinadas a taxa de exalação de 222Rn por meio da técnica da câmara de acumulação com detectores sólidos de traços nucleares (SSNTD) inseridos em uma câmara de difusão e a dose efetiva para um indivíduo habitando uma residência construída com esses materiais. A título de comparação foi também determinada a taxa de exalação teórica, por meio do modelo proposto pela UNSCEAR, a partir da concentração de 226Ra nas placas e tijolos de fosfogesso. A contribuição do revestimento na superfície dos materiais para a diminuição da taxa de exalação de radônio foi também avaliada. Foram estudados placas e tijolos fabricados com fosfogesso das empresas Bunge Fertilizantes, Ultrafertil e Fosfertil e tijolos fabricados com gesso comum. Os valores médios obtidos foram 0,19 0,06 Bq m-2 h-1, 1,3 0,3 Bq m-2 h-1 e 0,41 0,07 Bq m-2 h-1 para as placas fabricadas com fosfogesso proveniente das empresas Bunge, Ultrafertil e Fosfertil, respectivamente. Já para os tijolos de fosfogesso, os valores foram 0,11 0,01 Bq m-2 h-1, 1,2 0,6 Bq m-2 h-1, 0,47 0,15 Bq m-2 h-1, para o fosfogesso da Bunge, Ultrafertil e Fosfertil. O tijolo fabricado com gesso comum apresentou valor médio de 0,18 0,08 Bq m-2 h-1. As doses efetivas anuais para um indivíduo habitando uma residência construída como os tijolos ou placas de fosfogesso de qualquer uma das procedências ficaram abaixo do limite de dose efetiva para indivíduos do público de 1 mSva-1 estabelecido pela Comissão Internacional de Proteção Radiológica. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
10

Acetona exalada como novo biomarcador do diagnóstico de insuficiência cardíaca / Exhaled breath acetone as a new biomarker of heart failure diagnosis

Braga, Fabiana Goulart Marcondes 19 March 2012 (has links)
A insuficiência cardíaca é uma síndrome clínica de alta morbimortalidade e por este motivo é crescente o interesse em se estudar novos biomarcadores da doença visando buscar caminhos para novas estratégias terapêuticas. Neste contexto, a análise do ar exalado pode ser promissora. Baseado nestes dados e na observação de que pacientes com insuficiência cardíaca grave exalam odor peculiar, ainda em estudo piloto, nós identificamos acetona no ar exalado de pacientes com insuficiência cardíaca. Assim, nosso estudo teve por objetivo primário avaliar o papel da acetona exalada como biomarcador do diagnóstico de insuficiência cardíaca e de insuficiência cardíaca descompensada. Como objetivo secundário, avaliar sua relação com a classe funcional segundo a classificação da New York Heart Assocation (NYHA) e sua correlação com o peptídeo natriurético do tipo B (BNP). Entre maio de 2009 e setembro de 2010, pacientes consecutivos com disfunção sistólica (grupo IC) admitidos na emergência (insuficiência cardíaca descompensada grupo ICDESCOMP) e pacientes estáveis nos últimos três meses encaminhados para o teste cardiopulmonar (insuficiência cardíaca compensada grupo ICCOMP) foram submetidos à coleta de ar exalado (extração em água) para posterior análise qualitativa por cromatografia gasosa acoplado à espectrometria de massas e quantificação por espectrofotometria de absorção, através da reação com salicilaldeído. Entre os 235 pacientes avaliados, 89 foram incluídos (59 com insuficiência cardíaca descompensada e 30 com insuficiência cardíaca compensada), 61% do sexo masculino e com mediana de idade de 52 anos. Vinte indivíduos saudáveis (grupo controle) pareados por idade participaram do estudo. O valor mediano (intervalo interquartil) de acetona exalada foi maior no grupo IC em relação ao controle [3,70 g/L (1,69-10,45 g/L) versus 0,39 g/L (0,30-0,79 g/L), p < 0,001]. O valor mediano de acetona em pacientes com insuficiência cardíaca descompensada foi maior do que no grupo com insuficiência cardíaca compensada [7,80 g/L (3,60-15,20 g/L) versus 1,22 g/L (0,682,19 g/L), p < 0,001]. A acurácia do método tanto para o diagnóstico de insuficiência cardíaca (acetona > 1,16 g/L; área sob a curva = 0,94) quanto para o diagnóstico de insuficiência cardíaca descompensada (acetona > 2,50 g/L; área sob a curva = 0,93) foi aproximadamente 85 %, semelhante à acurácia do BNP (BNP > 42 pg/mL; área sob a curva = 0,97 e BNP > 424 pg/mL; área sob a curva = 0,94, respectivamente). Houve correlação positiva entre acetona exalada e BNP (r = 0,772, p < 0,001). Observamos aumento progressivo nas concentrações de acetona exalada de acordo com a piora da classe funcional segundo NYHA (p < 0,001). Assim, podemos concluir que nosso estudo revelou a acetona exalada como um novo biomarcador do diagnóstico de insuficiência cardíaca e de insuficiência cardíaca descompensada, que está associado à maior gravidade da doença e que apresenta correlação positiva com BNP. Sua dosagem é um novo método de diagnóstico não invasivo que pode ser realizado à beira leito, cuja acurácia é semelhante à do BNP / Heart failure (HF) is a condition associated with high mortality and frequent hospital admissions. In this context, multiple biomarkers of heart failure severity have emerged recently. However, the usefulness of most of these biomarkers has not been fully established. Exhaled breath has been considered a suitable tool (biomarker) to evaluate different diseases. Based on the clinical observation that patients with acute decompensated heart failure (ADHF) exhale a distinct odor, in a pilot study we have identified acetone in exhaled breath of heart failure patients and this study aimed to evaluate the role of acetone as a new biomarker of heart failure and ADHF disease. As secondary aims, we intended to analyze the relation to New York Heart Association (NYHA) class and the correlation with B-Type Natriuretic Peptide (BNP). Patients with systolic dysfunction (HF group) admitted consecutively at the emergency room (ADHF group) and stable patients referred to the cardiopulmonary test (chronic HF CHF group) between May 2009 and September 2010 were submitted to exhaled breath collection (extraction into water). Acetone identification was done by gas chromatography-mass spectrometry (GC-MS) and its determination by absorption spectrophotometry after reaction with salicylaldehyde. Twenty healthy subjects matched for age were enrolled (control group). Among 235 patients with HF, 89 were included in the study (59 ADHF and 30 CHF), 61% male, with median age of 52 years. Median exhaled breath acetone value (interquartile range) was higher in the HF group when compared to control group [3.7 g/L (1.69-10.45 g/L) versus 0.39 g/L (0.30-0.79 g/L), p < 0.001] and also higher in ADHF when compared to CHF group [7.80 g/L (3.60-15.20 g/L) versus 1.22 g/L (0.682.19 g/L), p < 0,001]. The accuracy of the method to diagnose CHF (Acetone > 1.16 g/L; AUC = 0.94) and ADHF (Acetone > 2.5 g/L; AUC = 0.93) was similar to the accuracy of BNP (BNP > 42 pg/mL; AUC = 0.97 and BNP > 424 pg/mL; AUC = 0.94, respectively). There was a positive correlation between exhaled breath acetone and plasmatic BNP (r = 0.772, p < 0.001). Levels of exhaled breath acetone were different among the four different NYHA classes (p<0.001). In summary, we can conclude that our study showed exhaled breath acetone as a new biomarker of heart failure and ADHF. It is associated with heart failure severity and has a good correlation with BNP. This is a promising non-invasive diagnostic method of heart failure, whose accuracy is equivalent to BNP

Page generated in 0.1219 seconds