• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Abordagem por ressonância magnética do mecanismo de ação da pressão expiratória positiva nasal como forma de tratamento da apneia do sono

Braga, Carla Winei January 2012 (has links)
Esta tese de doutorado aborda o assunto apneia do sono, especialmente a síndrome de apneia e hipopneia obstrutiva do sono (SAHOS) como principal motivo de investigação. Nosso estudo teve como objetivo estudar o mecanismo fisiológico de funcionamento da válvula expiratória nasal (nEPAP) denominada Provent. Trata-se de um dispositivo descartável utilizado em ambas as narinas e que permite a inspiração normal, porém oferece resistência à expiração, fazendo com que o próprio paciente gere uma determinada pressão expiratória nasal. Este mecanismo de atuação da válvula determina algum grau de modificação na via aérea superior e no pulmão. Embora já se saiba que este dispositivo é efetivo no tratamento de pacientes com SAHOS leve e moderada3 o seu mecanismo fisiológico de funcionamento ainda não está completamente entendido. Utilizamos um método de ressonância magnética para avaliar a via aérea superior e o pulmão de pacientes em utilização do Provent nasal. Estudamos dez pacientes, 7 homens e 3 mulheres, entre 30 e 62 anos, com diagnóstico clínico de SAHOS e confirmado pela polissonografia (IAH>5 ev/h). Realizamos então, em diferentes momentos, polissonografia diagnóstica, polissonografia em uso da válvula nasal e exame de imagem (ressonância magnética). A faringe e o pulmão foram inspecionados e medidos durante alguns ciclos respiratórios, com e sem a válvula nasal. Neste estudo, validamos o exame de Ressonância Magnética para a avaliação da área transversal da via aérea superior e da capacidade residual funcional durante a respiração através da válvula nasal. Com os nossos resultados reforçamos os achados anteriores da literatura referentes aos três possíveis mecanismos de funcionamento desta válvula nasal: hiperinflação pulmonar importante aumentando a tração na traqueia, uma tendência à dilatação da faringe durante a expiração que se mantém no início da inspiração reduzindo a colapsabilidade da faringe e, finalmente, hipoventilação e aumento de PCO2. Considerando estes resultados, podemos dizer que a pressão expiratória positiva nasal pode ser uma alternativa de tratamento da SAHOS. Os resultados deste estudo são apresentados sob a forma de artigo já publicado em revista internacional de alto impacto científico (Journal of Applied Physiology). Adicionalmente, na forma de apêndice, realizamos outro estudo objetivando estudar o comportamento da SAHOS na Doença de Parkinson e as alterações ocasionadas em marcadores periféricos de lesão neuronal, especificamente a proteína S100B e a Enolase. Os transtornos do sono, incluindo os distúrbios respiratórios, são frequentes nos pacientes com Doença de Parkinson (DP), e, estudos já realizados mostram que a proteína S100B pode estar aumentada tanto em pacientes com SAHOS1 como naqueles com Doença de Parkinson2, sugerindo a possibilidade de algum grau de dano neuronal nestes pacientes quando comparados com indivíduos normais. Estes achados serviram de motivação para o estudo das variáveis neurofisiológicas do sono e do comportamento de biomarcadores em pacientes com Parkinson e, supostamente, SAHOS concomitantemente. / The issue of this doctoral thesis is Obstructive Sleep Apnea (OSA). Our study intended to clarify the mechanism of action of nEPAP (Nasal Expiratory Positive Airway Pressure), delivered with a disposable device (Provent, Ventus Medical). It has been shown to improve sleep disordered breathing (SDB) in some subjects3, but how it works is still not completely understood. We studied 10 patients, 7 males and 3 females, age between 30 and 62 years old, with clinic OSA and confirmed by sleep study (IHA>5). Sleep studies were performed in different nights, a night for diagnostic of OSA and other night under nasal valve. We did use MRI (Magnetic Resonance Imaging) to see upper airway and lung in patients wearing Provent. The present study demonstrate that significant hyperinflation (an increase in end expiratory lung volume) occurs during breathing through the device. In addition, there may be some trend to dilate the UA during expiration, and this may carry over into inspiration, providing a second mechanism to reduce the tendency of the UA to collapse in patients with SDB. Finally, we were able to show significant hypoventilation and a rise in PCO2 during breathing through the nEPAP during wakefulness, which may persist into sleep. Results are presented in the format of a paper published in a international journal with high scientific impact (Journal of Applied Physiology). In addition, as appendix, we did perform other protocol intended to study OSA in the Parkinson Disease (PD) and correlation with detectable levels of S100B and NSE, biochemical markers of neuronal damage. Sleep breathing disorders are frequent in Parkinson Disease and there are some studies showing that S100B, a known biochemical marker of astrocyte damage, is increased in both SAOS and PD1 2, suggesting a possible neuronal damage while compared to controls. These findings were motivation to investigate biochemical markers and sleep in patients with Parkinson. Our results suggest that sleep disturbance in PD causes a worse sleep quality and leads to S100B elevation during the night. Probably PD patients are suffering some degree of brain damage during the night that trigger a S100B response.
2

Abordagem por ressonância magnética do mecanismo de ação da pressão expiratória positiva nasal como forma de tratamento da apneia do sono

Braga, Carla Winei January 2012 (has links)
Esta tese de doutorado aborda o assunto apneia do sono, especialmente a síndrome de apneia e hipopneia obstrutiva do sono (SAHOS) como principal motivo de investigação. Nosso estudo teve como objetivo estudar o mecanismo fisiológico de funcionamento da válvula expiratória nasal (nEPAP) denominada Provent. Trata-se de um dispositivo descartável utilizado em ambas as narinas e que permite a inspiração normal, porém oferece resistência à expiração, fazendo com que o próprio paciente gere uma determinada pressão expiratória nasal. Este mecanismo de atuação da válvula determina algum grau de modificação na via aérea superior e no pulmão. Embora já se saiba que este dispositivo é efetivo no tratamento de pacientes com SAHOS leve e moderada3 o seu mecanismo fisiológico de funcionamento ainda não está completamente entendido. Utilizamos um método de ressonância magnética para avaliar a via aérea superior e o pulmão de pacientes em utilização do Provent nasal. Estudamos dez pacientes, 7 homens e 3 mulheres, entre 30 e 62 anos, com diagnóstico clínico de SAHOS e confirmado pela polissonografia (IAH>5 ev/h). Realizamos então, em diferentes momentos, polissonografia diagnóstica, polissonografia em uso da válvula nasal e exame de imagem (ressonância magnética). A faringe e o pulmão foram inspecionados e medidos durante alguns ciclos respiratórios, com e sem a válvula nasal. Neste estudo, validamos o exame de Ressonância Magnética para a avaliação da área transversal da via aérea superior e da capacidade residual funcional durante a respiração através da válvula nasal. Com os nossos resultados reforçamos os achados anteriores da literatura referentes aos três possíveis mecanismos de funcionamento desta válvula nasal: hiperinflação pulmonar importante aumentando a tração na traqueia, uma tendência à dilatação da faringe durante a expiração que se mantém no início da inspiração reduzindo a colapsabilidade da faringe e, finalmente, hipoventilação e aumento de PCO2. Considerando estes resultados, podemos dizer que a pressão expiratória positiva nasal pode ser uma alternativa de tratamento da SAHOS. Os resultados deste estudo são apresentados sob a forma de artigo já publicado em revista internacional de alto impacto científico (Journal of Applied Physiology). Adicionalmente, na forma de apêndice, realizamos outro estudo objetivando estudar o comportamento da SAHOS na Doença de Parkinson e as alterações ocasionadas em marcadores periféricos de lesão neuronal, especificamente a proteína S100B e a Enolase. Os transtornos do sono, incluindo os distúrbios respiratórios, são frequentes nos pacientes com Doença de Parkinson (DP), e, estudos já realizados mostram que a proteína S100B pode estar aumentada tanto em pacientes com SAHOS1 como naqueles com Doença de Parkinson2, sugerindo a possibilidade de algum grau de dano neuronal nestes pacientes quando comparados com indivíduos normais. Estes achados serviram de motivação para o estudo das variáveis neurofisiológicas do sono e do comportamento de biomarcadores em pacientes com Parkinson e, supostamente, SAHOS concomitantemente. / The issue of this doctoral thesis is Obstructive Sleep Apnea (OSA). Our study intended to clarify the mechanism of action of nEPAP (Nasal Expiratory Positive Airway Pressure), delivered with a disposable device (Provent, Ventus Medical). It has been shown to improve sleep disordered breathing (SDB) in some subjects3, but how it works is still not completely understood. We studied 10 patients, 7 males and 3 females, age between 30 and 62 years old, with clinic OSA and confirmed by sleep study (IHA>5). Sleep studies were performed in different nights, a night for diagnostic of OSA and other night under nasal valve. We did use MRI (Magnetic Resonance Imaging) to see upper airway and lung in patients wearing Provent. The present study demonstrate that significant hyperinflation (an increase in end expiratory lung volume) occurs during breathing through the device. In addition, there may be some trend to dilate the UA during expiration, and this may carry over into inspiration, providing a second mechanism to reduce the tendency of the UA to collapse in patients with SDB. Finally, we were able to show significant hypoventilation and a rise in PCO2 during breathing through the nEPAP during wakefulness, which may persist into sleep. Results are presented in the format of a paper published in a international journal with high scientific impact (Journal of Applied Physiology). In addition, as appendix, we did perform other protocol intended to study OSA in the Parkinson Disease (PD) and correlation with detectable levels of S100B and NSE, biochemical markers of neuronal damage. Sleep breathing disorders are frequent in Parkinson Disease and there are some studies showing that S100B, a known biochemical marker of astrocyte damage, is increased in both SAOS and PD1 2, suggesting a possible neuronal damage while compared to controls. These findings were motivation to investigate biochemical markers and sleep in patients with Parkinson. Our results suggest that sleep disturbance in PD causes a worse sleep quality and leads to S100B elevation during the night. Probably PD patients are suffering some degree of brain damage during the night that trigger a S100B response.
3

Efeitos da aplicação da EPAP sobre a tolerância ao esforço em indivíduos portadores de insuficiência cardíaca / Effects of application of EPAP on exercise tolerance in individuals with heart failure

Thofehrn, Claudia 02 March 2012 (has links)
Made available in DSpace on 2016-12-06T17:06:54Z (GMT). No. of bitstreams: 1 Claudia Thofehrn.pdf: 804135 bytes, checksum: 1c917a778904272b382a9452df5cb3e7 (MD5) Previous issue date: 2012-03-02 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Patients with heart failure (HF) are often limited by dyspnea and fatigue, often aggravated by pulmonary congestion present in this syndrome. Efficacy of Positive Expiratory Pressure Airway (EPAP) has been tested in diverse populations, as in the postoperative period of CABG surgery, stable chronic obstructive pulmonary disease and obstructive sleep apnea, providing effects such as variation in intraocular pressure alveolar, increased functional residual capacity, redistribution of extravascular fluid and decreased intrapulmonary shunt. In an attempt to reduce dyspnea and respiratory work in patients with HF using the EPAP is a therapeutic alternative in view of its beneficial effects and considering the changes in lung function are related to pulmonary edema. The aim of this study was to evaluate the effects of the use of EPAP on exercise tolerance in patients with HF, functional class II and III (NYHA). For the sample, we selected 28 patients with LVEF <40%, which conducted three tests of 6-minute walk (6MWT): learning with and without use of EPAP use of it. To generate a positive expiratory pressure, adapted to the mask expiratory resistor by a spring loaded set to offer a pressure of 8 cmH2O. The comparison between the data obtained was performed by paired t test or Wilcoxon test, depending on the normality of the data. As a result, it was found that the use of EPAP increased without significant minute volume and the perception of effort was increased after 6MWT that the associated use of positive pressure. With regard to oxygen saturation, the use of EPAP in 6MWT increased significantly the same, despite the finding baseline saturations were within normal parameters before testing. It was concluded that the use of EPAP did not increase exercise tolerance in patients with HF in the 6MWT, but there is a need for additional studies to test different levels of the same long-term training and / or analyze patients with degrees of clinic more pronounced. / Pacientes portadores de Insuficiência Cardíaca (IC) frequentemente são limitados pela dispnéia e fadiga, muitas vezes agravadas pela congestão pulmonar presentes nesta síndrome. A eficácia da Pressão Positiva Expiratória nas Vias Aéreas (EPAP) já foi testada em diversas populações, como em pós-operatório de cirurgia de revascularização miocárdica, doença pulmonar obstrutiva crônica estável e apneia obstrutiva do sono, proporcionando efeitos como a variação na pressão intra-alveolar, aumento da capacidade residual funcional, redistribuição do líquido extravascular e diminuição do shunt intrapulmonar. Na tentativa de reduzir a dispnéia e o trabalho ventilatório em portadores de IC o uso da EPAP é uma alternativa terapêutica, tendo em vista seus efeitos benéficos e considerando que as alterações na função pulmonar estão relacionadas à edema pulmonar. O objetivo desta pesquisa foi avaliar os efeitos da utilização da EPAP sobre a tolerância ao esforço em indivíduos portadores de IC, classe funcional II e III (NYHA). Para a amostra, foram selecionados 28 pacientes com FEVE < 40%, os quais realizaram três testes de caminhada de 6 minutos (TC6 ): aprendizado, com uso da EPAP e sem uso da mesma. Para gerar a pressão positiva expiratória, adaptou-se à uma máscara um resistor expiratório por carga de mola ajustado para oferecer uma pressão de 8 cmH2O. A comparação entre os dados obtidos foi realizada por meio de teste t pareado ou teste de Wilcoxon, conforme a normalidade dos dados. Como resultado, verificou-se que o uso da EPAP aumentou sem significância o volume minuto, porém a percepção de esforço foi maior após o TC6 que associou o uso da pressão positiva. Com relação à saturação de oxigênio, o uso da EPAP no TC6 elevou a mesma significativamente, apesar das saturações basais encontrarem-se dentro de parâmetros normais antes da realização do teste. Concluiu-se que o uso da EPAP não promoveu aumento na tolerância ao esforço em indivíduos portadores de IC no TC6 , porém, há a necessidade de estudos adicionais que testem níveis diferentes da mesma no treinamento a longo prazo e/ou analisem pacientes com graus de descompensação clínica mais acentuada.
4

Abordagem por ressonância magnética do mecanismo de ação da pressão expiratória positiva nasal como forma de tratamento da apneia do sono

Braga, Carla Winei January 2012 (has links)
Esta tese de doutorado aborda o assunto apneia do sono, especialmente a síndrome de apneia e hipopneia obstrutiva do sono (SAHOS) como principal motivo de investigação. Nosso estudo teve como objetivo estudar o mecanismo fisiológico de funcionamento da válvula expiratória nasal (nEPAP) denominada Provent. Trata-se de um dispositivo descartável utilizado em ambas as narinas e que permite a inspiração normal, porém oferece resistência à expiração, fazendo com que o próprio paciente gere uma determinada pressão expiratória nasal. Este mecanismo de atuação da válvula determina algum grau de modificação na via aérea superior e no pulmão. Embora já se saiba que este dispositivo é efetivo no tratamento de pacientes com SAHOS leve e moderada3 o seu mecanismo fisiológico de funcionamento ainda não está completamente entendido. Utilizamos um método de ressonância magnética para avaliar a via aérea superior e o pulmão de pacientes em utilização do Provent nasal. Estudamos dez pacientes, 7 homens e 3 mulheres, entre 30 e 62 anos, com diagnóstico clínico de SAHOS e confirmado pela polissonografia (IAH>5 ev/h). Realizamos então, em diferentes momentos, polissonografia diagnóstica, polissonografia em uso da válvula nasal e exame de imagem (ressonância magnética). A faringe e o pulmão foram inspecionados e medidos durante alguns ciclos respiratórios, com e sem a válvula nasal. Neste estudo, validamos o exame de Ressonância Magnética para a avaliação da área transversal da via aérea superior e da capacidade residual funcional durante a respiração através da válvula nasal. Com os nossos resultados reforçamos os achados anteriores da literatura referentes aos três possíveis mecanismos de funcionamento desta válvula nasal: hiperinflação pulmonar importante aumentando a tração na traqueia, uma tendência à dilatação da faringe durante a expiração que se mantém no início da inspiração reduzindo a colapsabilidade da faringe e, finalmente, hipoventilação e aumento de PCO2. Considerando estes resultados, podemos dizer que a pressão expiratória positiva nasal pode ser uma alternativa de tratamento da SAHOS. Os resultados deste estudo são apresentados sob a forma de artigo já publicado em revista internacional de alto impacto científico (Journal of Applied Physiology). Adicionalmente, na forma de apêndice, realizamos outro estudo objetivando estudar o comportamento da SAHOS na Doença de Parkinson e as alterações ocasionadas em marcadores periféricos de lesão neuronal, especificamente a proteína S100B e a Enolase. Os transtornos do sono, incluindo os distúrbios respiratórios, são frequentes nos pacientes com Doença de Parkinson (DP), e, estudos já realizados mostram que a proteína S100B pode estar aumentada tanto em pacientes com SAHOS1 como naqueles com Doença de Parkinson2, sugerindo a possibilidade de algum grau de dano neuronal nestes pacientes quando comparados com indivíduos normais. Estes achados serviram de motivação para o estudo das variáveis neurofisiológicas do sono e do comportamento de biomarcadores em pacientes com Parkinson e, supostamente, SAHOS concomitantemente. / The issue of this doctoral thesis is Obstructive Sleep Apnea (OSA). Our study intended to clarify the mechanism of action of nEPAP (Nasal Expiratory Positive Airway Pressure), delivered with a disposable device (Provent, Ventus Medical). It has been shown to improve sleep disordered breathing (SDB) in some subjects3, but how it works is still not completely understood. We studied 10 patients, 7 males and 3 females, age between 30 and 62 years old, with clinic OSA and confirmed by sleep study (IHA>5). Sleep studies were performed in different nights, a night for diagnostic of OSA and other night under nasal valve. We did use MRI (Magnetic Resonance Imaging) to see upper airway and lung in patients wearing Provent. The present study demonstrate that significant hyperinflation (an increase in end expiratory lung volume) occurs during breathing through the device. In addition, there may be some trend to dilate the UA during expiration, and this may carry over into inspiration, providing a second mechanism to reduce the tendency of the UA to collapse in patients with SDB. Finally, we were able to show significant hypoventilation and a rise in PCO2 during breathing through the nEPAP during wakefulness, which may persist into sleep. Results are presented in the format of a paper published in a international journal with high scientific impact (Journal of Applied Physiology). In addition, as appendix, we did perform other protocol intended to study OSA in the Parkinson Disease (PD) and correlation with detectable levels of S100B and NSE, biochemical markers of neuronal damage. Sleep breathing disorders are frequent in Parkinson Disease and there are some studies showing that S100B, a known biochemical marker of astrocyte damage, is increased in both SAOS and PD1 2, suggesting a possible neuronal damage while compared to controls. These findings were motivation to investigate biochemical markers and sleep in patients with Parkinson. Our results suggest that sleep disturbance in PD causes a worse sleep quality and leads to S100B elevation during the night. Probably PD patients are suffering some degree of brain damage during the night that trigger a S100B response.

Page generated in 0.0929 seconds