• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 488
  • 7
  • 6
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 510
  • 370
  • 362
  • 357
  • 353
  • 292
  • 287
  • 273
  • 122
  • 68
  • 58
  • 53
  • 53
  • 52
  • 45
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

"Espalhamento Compton e medida absoluta da energia de fótons marcados - Uma simulação Monte Carlo" / Compton scattering and absolute measurement of tagged photon energies.

Carvalho Junior, Washington Rodrigues de 08 March 2005 (has links)
Uma simulação baseada em métodos Monte Carlo foi criada com o intuito de avaliar a potencialidade da utilização do espalhamento Compton em altas energias para a obtenção de medidas absolutas e de alta precisão da energia de fótons marcados. Esse método se baseia em medidas angulares dos produtos desse espalhamento para reconstruir a energia dos fótons incidentes, utilizando a cinemática do espalhamento Compton em aproximação de impulso. A simulação inclui vários efeitos relevantes à medida, como espalhamento múltiplo de elétrons, momento interno dos elétrons nos átomos do alvo, resolução do detetor e vários parâmetros geométricos do arranjo experimental. Através da simulação de um experimento que utiliza esse método para a calibração em energia de um feixe de fótons marcados, foi possível identificar duas fontes de erros sistemáticos. Métodos de análise que minimiza um desse erros sistemáticos foram desenvolvidos, bem como métodos para a criação de correções para as medidas de energia. Verificou-se que, pelo menos no arranjo experimental estudado, é possível obter medidas da energia dos fótons incidentes com precisão da ordem de 0.07%. / A simulation based on Monte Carlo methods was created in order to evaluate the potentiality of using Compton scattering at high energies to obtain high precision absolute measurements of tagged photon energies. This method is based on angular measurements of the scattering products to reconstruct the incident photon energy using the kinematics of Compton scattering in impulse approximation. The simulation includes several effects that are relevant to the measurement, such as electron multiple scattering, internal momentum of the electrons in the atoms of the target, detector resolution and several geometrical parameters of the experimental setup. Through simulation of an experiment that uses this method for energy calibration of a tagged photon beam, it was possible to identify two sources of systematic errors. Analysis methods that minimize one of these systematic errors were developed, as well as methods for the creation of corrections to the energy measurements. Our results show that, at least in the studied experimental setup, it is possible to obtain energy measurements with a precision in the order of 0.07%.
72

Análise tridimensional das vias aéreas superiores de pacientes com fissura labiopalatina e discrepância maxilomandibular / Three-dimensional analysis of the upper airways of patients with cleft palate and maxillomandibular discrepancy

Lima, Thiago Freire 02 March 2015 (has links)
Objetivos: As fissuras labiopalatinas constituem a malformação congênita de maior prevalência na espécie humana. O fechamento cirúrgico do lábio e do palato, que visa restaurar a forma e a função, paradoxalmente impacta negativamente sobre o crescimento maxilar e, consequentemente, sobre a morfofisiologia nasal, levando à deformidades como desvio de septo e hipertrofia das conchas nasais. Estas alterações reduzem as dimensões internas da cavidade nasal e aumentam a resistência ao fluxo aéreo respiratório. Assim, foi objetivo do presente estudo avaliar tridimensionalmente o espaço aéreo faríngeo dos pacientes com fissura labiopalatina unilateral completa por meio de tomografia computadorizada de feixe cônico. Material e Métodos: Foram avaliados exames tomográficos de dois grupos de pacientes: 1) Grupo Controle (GC): 30 tomografias de pacientes sem FLP + discrepância maxilomandibular do tipo classe III de Angle, e, 2) Grupo Fissura (GF): 30 tomografias de pacientes com FLP unilateral completa + discrepância maxilomandibular do tipo classe III de Angle. Dois avaliadores treinados e calibrados avaliaram, em dois tempos distintos, as imagens por meio do software Dolphin Imaging 11.0, no qual foram obtidos valores de volume (V) faríngeo e da área seccional mínima faríngea (ASM). Os valores médios da ASM e do V, obtidos nas duas medições do avaliador 1, foram considerados para análise. A reprodutibilidade intra e interexaminador foram calculadas pelo oeficiente de Correlação Intraclasse. A significância das diferenças entre os grupos foram avaliadas pelo teste t de Student para amostras independentes. A correlação entre as variáveis foi aferida pelo Coeficiente de correlação de Pearson. Valores de p<0.05 foram considerados significantes. Resultados: Os valores médios de V (mm3) do GF (20,9±5,0) foram significantemente menores que os do GC (26,9±9,6) (p=0,004). Apesar de estatisticamente não significante, os indivíduos do GF apresentam as ASMs dimensionalmente menores (158,6±99,1) que as do GC (188,8±110,2). Constatou-se forte correlação positiva entre as variáveis ASM e V, nos grupos GC e GF (p<0.001) e forte correlação negativa entre as variáveis ASM e idade, apenas no grupo GF (p=0.017). Conclusão: A faringe do paciente com fissura labiopalatina unilateral completa com discrepância dento-esquelética classe III de Angle é volumetricamente menor que a de indivíduos sem fissura labiopalatina com o mesmo tipo de discrepância dento-esquelética. Este resultado sugere maior chance de colapsabilidade da faringe, e, consequentemente, maior risco para apneia obstrutiva do sono nesta população. / Objective: Cleft lip and palate (CLP) is the most prevalent congenital malformation in humans. Primary plastic surgeries, which main objective is to repair the anatomy and the function of the lip and palate, paradoxically, impair maxillary growth and, consequently, impact negatively on the nasal morphophysiology, leading to deformities such as septal deviation and turbinate hypertrophy. These changes reduce the internal nasal dimensions and increase the resistance to respiratory airflow. The aim of the present study was to evaluate three-dimensionally the pharyngeal airway space of individuals with complete unilateral cleft lip and palate by means of cone beam computed tomography. Materials and Methods: Two groups were evaluated: 1) Control group (CoG): 30 CT scans of individuals without CLP + Angle class III malocclusion, and 2) Cleft group (ClG): 30 CT scans of individuals with CLP + Angle class III malocclusion. Two trained and calibrated examiners assessed the images, in two different moments, by means of Dolphin Imaging 11.0 software. Mean values of pharyngeal volumes (V) and minimal cross-sectional areas (CSA) obtained by examiner 1 were considered for analysis. Intra and inter-examiner reproducibility were assessed by Intraclass correlation coeficiente test. The significance of differences between groups was evaluated by Student \"t\" test for independent samples. The correlation between variables was assessed using Pearson\'s correlation coefficient. P values <0.05 were considered significant. Results: Mean values of V (mm3) for the ClG (20,9±5,0) were significantly lower than for the CoG (26,9±9,6) (p=0,004). Although not statistically significant, individuals from the ClG presented with lower ASMs (158,6±99,1) than the CG individuals (188.8±110,2). A strong positive correlation was observed between the ASM and V variables in both groups (p <0.001) and a strong negative correlation was observed between the variables ASM and age, only for the ClG (p = 0.017). Conclusion: The pharynx of the patients with complete unilateral cleft lip and palate and with Angle Class III malocclusion is volumetrically smaller than that of individuals without cleft lip and palate and with the same type of skeletal discrepancy. This result suggests a greater chance for pharyngeal collapsibility in individuals with cleft lip and palate and, consequently, a greater risk for obstructive sleep apnea in this population.
73

Interferência dos artefatos de imagem causados por acessórios ortodônticos metálicos em sobreposições de imagens de TCFC / Influence of streaking artifacts due to metallic orthodontic accessories in CBCT 3D model superimposition

Silva, Fernando Penteado Lopes da 06 July 2012 (has links)
O objetivo deste estudo foi avaliar, de forma quantitativa e qualitativa, se artefatos de imagem causados por acessórios ortodônticos metálicos interferem em sobreposições tridimensionais (3D) de imagens de Tomografia Computadorizada de Feixe Cônico (TCFC). Dez crânios secos humanos foram submetidos a três aquisições tomográficas: sem acessórios ortodônticos (T1), com braquetes e tubos ortodônticos de aço inoxidável colados às superfícies vestibulares dos dentes superiores e inferiores (T2), e com fios ortodônticos de aço inoxidável inseridos nas canaletas dos referidos acessórios (T3). Os arquivos DICOM originais foram convertidos em arquivos de imagem Analyze, por meio do software Medsquare. O passo seguinte constituiu-se no registro rígido entre os pares de imagens T2-T1 e T3-T1, por meio do software Bioimage. Após o registro, foram então realizadas as sobreposições 3D entre os referidos pares de imagens, utilizando-se o software MeshValmet. Este software realiza uma codificação por mapas de cores, a partir das distâncias obtidas durante o processo de sobreposição. Distâncias positivas são codificadas com tonalidades de vermelho, enquanto que as negativas recebem tonalidades de azul. A ausência de deslocamento entre estruturas sobrepostas recebem o valor 0,0mmm sendo codificadas com a cor verde. As imagens referentes a T2 e T3 foram sobrepostas em relação à T1 no mesmo plano de espaço, para cada crânio da amostra. A partir das referidas sobreposições, foram calculadas as seguintes medidas: Distâncias Máxima, Mínima e Média, Distância Mean Square (MSD), Distância Root Mean Square (RMS) e Mediana. Estas quatro últimas caracterizaram-se como medidas de tendência central, e representaram a faixa de valores de maior concentração de dados. Os acessórios metálicos causaram artefatos de imagem principalmente nas imagens T2 e T3, porém os mesmos não comprometeram o processo de sobreposição das mesmas em relação à T1. As Distâncias Máximas foram comparadas à medida Diagonal (D), calculada a partir das dimensões dos acessórios ortodônticos e representativa dos mesmos (D=7,5mm). Nesta comparação, o teste t de Student não mostrou diferença significativa (p 0,05) indicando, de forma numérica, que os artefatos não se mostraram estatisticamente importantes em relação às dimensões dos corpos metálicos que os causaram. As medidas de tendência central foram então comparadas ao valor 0,0mm, o qual representa ausência total de deslocamento entre as imagens sobrepostas. Neste caso, o teste t também não evidenciou diferença significativa (p 0,05), indicando que a maior concentração de distâncias entre pontos em T2-T1 e T3-T1 localizou-se próxima ao referido valor. Somado a isso, a avaliação qualitativa propiciada pelas imagens corroborou tal constatação. Na comparação entre as medidas em T2-T1 e T3-T1, os coeficientes de Pearson mostraram alta correlação em relação às medidas de tendência central, como Distância Média (r=0.86), MSD (r=0.87), RMS (r=0.97) e Mediana (r=0.74). Mediante a avaliação quantitativa, complementada pela interpretação qualitativa dos dados, concluiu-se que os artefatos de imagem não comprometeram o procedimento de sobreposição de modelos 3D no presente estudo. / The aim of this study was to determine whether the artifacts caused by orthodontic metallic accessories interfere with the accuracy of three-dimensional (3D) Cone Beam Computed Tomography (CBCT) model superimposition. Ten dry human skulls were subjected to 3 CBCT scans: without orthodontic brackets (T1), with stainless steel brackets bonded (T2) and with orthodontic arch wires inserted into the bracket slots (T3). Individual 3D surface models were generated for the T1, T2 and T3 images, and the within-surface distances between T2-T1 and T3-T1 were computed. Superimposition error was calculated assuming CBCT image registration of T2 and T3 with respect to T1 using plain superimposition. The following measures were evaluated: Maximum, Mean and Mean Square Distance (MSD), Root MSD (RMS) and Median. The metallic accessories caused image artifacts primarily in T2 and T3 images which, however, did not compromise the 3D model superimposition. The maximum distances of artifacts image points were compared to the representative measure of orthodontic accessories (7.5mm), and Student t test showed no significant differences (p0.05) between both measures. When measures of T2-T1 and T3-T1 were compared, the Pearson coefficients showed a high correlation regarding the central tendency measures, as follows: Mean Distance (r=0.86), MSD (r=0.87), RMS (0.97) and Median (r=0.74). The statistical findings, which were complemented by qualitative image data obtained from this study, depicted that streaking artifacts did not affect the accuracy of CBCT 3D model superimposition of dry human skulls.
74

Foraminas acessórias mandibulares em tomografia computadorizada de feixe cônico / Accessory mandibular foramina in cone-beam computed tomography

Ikuta, Carla Renata Sanomiya 29 May 2014 (has links)
Com o surgimento da Tomografia Computadorizada de Feixe Cônico (TCFC) foi possível observar estruturas anatômicas que antes não eram visualizadas em radiografias convencionais, como a foramina lingual lateral (FLL). A FLL é um orifício localizado na região posterior lingual da mandíbula que se comunica com o canal mandibular (CM). O objetivo do estudo foi avaliar a presença da FLL em 100 exames de TCFC obtidas pelo aparelho i-CAT Classic®. A presença da FLL foi comparada entre gênero e idade. As FLL foram localizadas em pacientes dentados através de 5 áreas: primeiro pré-molar inferior (A), segundo pré-molar inferior (B), primeiro molar inferior (C), segundo molar inferior (D) e terceiro molar inferior (E). Foram realizadas as medidas de diâmetro axial (DA), diâmetro coronal (DC) e a distância de FLL ao forame mentual (FLL-FM), e FLL à borda inferior da mandíbula (FLL-BI). A FLL estava presente em 39% (39/100) dos exames e foram encontradas 52 FLL (26 exames unilaterais e 13, bilaterais). O lado direito apresentou 29 FLL, enquanto o lado esquerdo 23. A região onde mais foi encontrada FLL foi a região B. 21 foraminas foram encontradas na posição lingual ao FM. O valor médio do DA foi de 1,26±0,57 mm e do DC de 1,82±1,12 mm. Os valores médios da distância de FLLFM e FLL-BI foram 12,74±7,7 e 5,82±2,78 mm, respectivamente. Não houve diferença estatisticamente significante da presença da FLL entre a idade ou o sexo. A medida FLL-FM foi maior em homens tanto do lado direito como do lado esquerdo, mostrando uma diferença estatisticamente significante (p=0,032). / Cone-beam Computed Tomography (CBCT) allowed viewing some anatomical structures that were not noted in bi-dimensional images, such as lateral lingual foramina (LLF). LLF is an aperture located in posterior lingual mandible area, linked with mandibular canal (MC). The present study evaluated the LLF presence through 100 CBCT images, obtained by i-CAT Classic®. Presence or absence of LLF was compared between sex and age. The LLF was located in dentate patients through 5 areas: first lower pre-molar (A), second lower pre-molar (B), first lower molar (C), second lower molar (D) and third lower molar (E). Was measured axial diameter (AD) and coronal diameter (DC), and, the distance from LLF to mentual foramen (LLF-MF) and from LLF to lower mandible border (LLF-LMB). These measures were also compared between gender. LLF was observed in 39% of the exams (39/100). Fiftytwo LLF were found (26 unilateral and 26 bilateral). Right and left sides presented 29 LLF and 23 LLF respectively. The most prevalent area of LLF occurrence was B area. 21 LLF was located in lingual position of MF. The mean average of AD was 1,26±0,57 mm, and CD was 1,82±1,12 mm. The mean average values of LLF-MF and LLF-BI distances were 12,74±7,7 and 5.82±2,78 mm, respectively. There was no statistical difference of gender or age correlated with LLF presence. Men have LLFMF distance greater than woman, showing no statistically significant difference (p=0,032).
75

Estudos anatômicos, ultra-estruturais e bioquímicos da síndrome Kranz em folhas de duas espécies de Gomphrena L. (Amaranthaceae) / Anatomical, ultrastructural and biochemical surveys in leaves to two Gomphrena L. species (Amaranthaceae)

Antonucci, Natalia Paganotti 10 March 2010 (has links)
A síndrome Kranz é um conjunto de características anatômicas, ultra-estruturais e bioquímicas que culminam na realização da fotossíntese C4. Tal síndrome apresenta grande diversidade dentre as Angiospermas, tornando-se conveniente seu estudo em todos os níveis acima citados para a completa caracterização da mesma. No presente trabalho foi investigada a síndrome Kranz de Gomphrena arborescens e G. scapigera (Amaranthaceae) com ênfase na origem ontogenética da bainha Kranz, na descrição ultra-estrutural e na confirmação bioquímica sobre o tipo de fotossíntese C4. O desenvolvimento foliar dessas espécies indica que a bainha Kranz é originada da camada mais interna do mesofilo, a endoderme foliar. Uma discussão sobre os termos presentes na literatura para a descrição dessa bainha, todos eles focados em sua função na fotossíntese C4, demonstra a importância de se utilizar termos que informem a origem ontogenética dessa bainha, como endoderme e periciclo. Na análise ultra-estrutural, foram identificados possíveis fatores que interferem na fotossíntese de ambas as espécies, como o espessamento e a composição da parede da bainha Kranz, o posicionamento centrípeto dos cloroplastos e a presença de retículo periférico nos mesmos. Embora a análise bioquímica tenha resultado em informações ainda não conclusivas, o dimorfismo dos cloroplastos sugere a realização da fotossíntese C4 do tipo NADP-ME. O presente trabalho, de uma forma geral, contribui ao conhecimento da síndrome Kranz dentre as Amaranthaceae s.s., um grupo em que a ultra-estrutura e a bioquímica ainda são pouco conhecidas, e ressalta a importância dos estudos anatômicos, principalmente com enfoque ontogenético, para o melhor conhecimento da diversidade da síndrome Kranz dentre as Angiospermas. / The Kranz syndrome is a set of anatomical, ultrastructural and biochemical features that culminate in the C4 photosynthesis. This syndrome has a huge diversity among Angiosperms, so it became suitable to survey all the levels above cited for its complete characterization. In the present work the Kranz syndrome of Gomphrena arborescens and G. scapigera (Amaranthaceae) is studied, with emphasis on the ontogenetic origin of the Kranz sheath, on the ultrastructural description, and on the biochemical confirmation about the C4 photosynthesis kind. The foliar development of these species shows that the Kranz sheath is originated from the inner layer of the mesophyll, the foliar endodermis. A discussion about the literature terms used to describe the Kranz sheath, all of them referring to the function of this layer in C4 photosynthesis, demonstrates the importance of using terms that inform the ontogenetic origin of this layer, such as endodermis and perycicle. The ultrastructural analysis identified possible factors that interfere on the C4 photosynthesis of both species, such as wall thickening and composition of Kranz sheath cells, the centripetal position of chloroplasts and the peripheral reticulum in chloroplasts. Although biochemical analysis has resulted in no conclusive information, the chloroplast dimorphism suggests the NADP-ME C4 photosynthesis. This work, in a general way, contributes to the knowledge of the Kranz syndrome among Amaranthaceae s.s., a group that has the ultrastructure and the biochemistry of C4 photosynthesis poorly known. It also draws attention to the importance of anatomical surveys concerning the ontogenetic origin of Kranz sheath for a better understanding on the diversity of Kranz syndrome among Angiosperms.
76

Possibilidades de produção de feixes atômicos monoenergéticos / Prospects for producing monoenergetic atomic beams

Colussi, Valdir Carlos 07 July 1992 (has links)
Neste trabalho, apresentamos um estudo detalhado da técnica de desaceleração e aceleração de átomos pelo ajuste Zeeman, possibilitando a produção de um feixe atômico monoenergético. Usando esta técnica, realizamos estudos sobre efeito de bombeameto óptico e condições de seguimento adiabático dos átomos no campo magnético. Através do entendimento destes efeitos, pudemos propor modificações que permitirão a produção de um fluxo intenso de átomos monoenergéticos, que deverão permitir experimentos, com este tipo de feixe atômico, fora do sistema / We have carefully studied the Zeeman-tuned technique to decelerate and also accelerate sodium atoms atomic beam, creating ways of producing monoenergetic atomic beams. A systematic study of the optical pumping effects on these beams, as well as its adiabatic following conditions along the magnetic field were also investigated. A single laser beam, together with minor changes on the the magnetic field profile and on the optical setup, was used to decelerate and/or to accelerate atoms running outside of the Zeeman solenoid, simplifying and speeding up the experimental runs
77

Construção de um acelerador de elétrons de 20KeV: aplicação ao estudo dos polímeros. / Development of a 20KeV electron gun for the study pf polymers.

Sandonato, Gilberto Marrega 05 August 1983 (has links)
Construiu-se um acelerador de elétrons de baixa energia (Máximo de 20 KeV). Como fonte de elétrons utilizou-se um canhão de elétrons de cinescópio preto e branco, ou seja, com um único emissor termiônico. A energia do feixe eletrônico pode ser continuamente variada desde 0 a 20 KeV. A corrente eletrônica pode ser variada desde um valor mínimo de 10-12A a 3&#956A, permanecendo constante no tempo uma vez fixado o seu valor. Através da focalização ou desfocalização da imagem do feixe de elétrons, é possível variar-se a área irradiada desde um diâmetro mínimo de 1 milímetro a um máximo de 6 cm. A pressão final atingida nas câmaras de vácuo foi da ordem de 10-7Torr. Durante o funcionamento do canhão de elétrons, o cátodo do mesmo é danificado devido ao bombardeamento de íons em sua superfície. Para examinarmos o grau de danificação causado por este bombardeamento iônico, basta focalizarmos e examinarmos a imagem de feixe eletrônico sobre uma tela luminescente. Deve-se ressaltar que todo o acelerador de elétrons foi construído a partir de materiais e componentes totalmente nacionais. O acelerador de elétrons foi aplicado para estudar efeitos de irradiação de elétrons em Teflon usando-se o método do Split Faraday Cup. Foram medidas correntes transitórias de carga e descarga e determinaram-se o alcance médio dos elétrons e o valor da condutividade induzida pela radiação. / We have constructed a low energy electron accelerator (maximum energy 20 KeV). A black and white kinescope electron gun, with a single thermionic emitter was used as an electron source. The energy of electron beam can be changed continuously from 0 to 20 KeV. The intensity of the current can be changed from a minimum of 10-12A to a maximum of 3&#956A, and can be maintained constant in time after its value has been fixed. The irradiated area can be changed from a diameter of 1 millimeter to a maximum of 6 centimeter, by focalizing or defocalizing the image of electron beam. The final pressure reached in vacuum chambers was 10-7Torr. During operation the surface of cathode of electron gun is damaged by ion bombardment. The degree of damage can be checked if the cathode image is focalized and examined on a luminescent screen. The accelerator was used to study electron irradiation effects in Teflon, employing the method of the Split Faraday Cup. Transient charging and discharging currents were measured. The average range of electrons of the electrons and induced conductivity were determined.
78

Ultrassom de alta frequência para avaliação da tábua óssea vestibular de implantes dentais / High frequency ultrasound for evaluation of buccal bone surrounding dental implants

Bohner, Lauren Oliveira Lima 25 July 2017 (has links)
Objetivo: Avaliar a exatidão do ultrassom de alta frequência na mensuração das dimensões lineares tanto da tábua óssea vestibular como de defeitos periimplantares circundando implantes dentais. Materiais e Métodos: Em uma primeira etapa, implantes dentais (n=10) foram instalados na maxila de 3 crânios secos e escaneados com ultrassom de alta frequência (UAF) e tomografia computadorizada de feixe cônico (TCFC). As seguintes medidas lineares foram determinadas para avaliação: A) espessura óssea; B) nível ósseo. As medições foram comparadas com valores de referência determinados pela microscopia óptica. A segunda etapa do experimento envolveu amostras de osso porcino contendo defeitos ósseos ao redor dos implantes dentais (n=10), as quais foram escaneadas com ultrassom de alta frequência e tomografia computadorizada de feixe cônico. As seguintes medidas foram realizadas nos defeitos periimplantares: A) componente supra-alveolar, B) componente intra-ósseo e C) espessura do defeito. Os valores de referência foram determinado pela microtomografia computadorizada e o erro de medição (diferença entre grupo teste e controle) foi determinado. Os dados foram analisados estatisticamente considerando um nível de significância de p<=0.05. Resultados: Não houve diferença estatisticamente significante entre os grupos para as medições da espessura óssea e nível ósseo (p>0.05). Em relação à espessura óssea, a discrepância foi de 0.17mm para o UAF e 0.02mm para a TCFC. Para o nível ósseo, a discrepância foi de 0.55mm para o UAF e 0.12mm para a TCFC. Ao considerar o erro de medição dos equipamentos na mensuração de defeitos periimplantares, não houve diferença estatisticamente significante entre o UAF e TCFC (UAF= 0.54±0.69mm; TCFC= 0.62±0.55mm). Conclusão: O ultrassom de alta frequência apresentou exatidão para a mensuração das dimensões lineares da tábua óssea vestibular e de defeitos periimplantares circundando implantes dentais. / Purpose: To evaluate the accuracy of a high frequency ultrasound scanner (HFU) to the measurement of buccal bone and periimplant defects surrounding dental implants. Materials and Methods: The first phase of this study comprised the installation of dental implants (n=10) in the maxillary of 3 dry skulls. The dental implants were scanned with a high frequency ultrasound scanner and a cone-beam computed tomography (CBCT). The following measurements were determined for evaluation: A) bone thickness, and B) bone level. The measurements were compared with reference values determined by an optical microscopy. The second phase comprised the installation of dental implants (n=10) in porcine bone samples containing bone defects surrounding dental implants. The bone samples were scanned with a high frequency ultrasound and cone-beam computed tomography and the following measurements were performed: A) supra-alveolar component, B) intra-bony component and C) thickness. The reference values were determined by a micro-computed tomography and the measurement error (difference between experimental and control group) was determined for each group. All measurements were statistically analyzed with a significance level of p<=0.05. Results: There was no statistically significant difference between ultrasound and cone-beam computed tomography for the measurement of buccal bone (p>0.05). With regard to the bone thickness, the discrepancy to the reference values was 0.17mm for HFU and 0.02mm for CBCT. For bone level, the discrepancy was 0.55mm for HFU and 0.12mm for CBCT. The measurement error from both the devices not differed statistically (HFU= 0.54±0.69mm; CBCT= 0.62±0.55mm). Conclusion: The high frequency ultrasound presented accuracy for the measurement of buccal bone and periimplant defects surrounding dental implants.
79

Estudo dos canais alveolares superiores e do canal infra-orbital por meio da tomografia computadorizada de feixe cônico / Study of the superior alveolar canals and infraorbital canal using cone beam computed tomography

Nicolielo, Laura Ferreira Pinheiro 23 August 2013 (has links)
Para oferecer mais informações aos cirurgiões no planejamento de intervenções cirúrgicas maxilofaciais, o presente estudo teve como objetivo avaliar a presença, localização e tamanho dos canais alveolares superiores (CAS), anterior (CASA) e posterior (CASP), canal infra-orbital (CI) e forame infra-orbital (FI) em imagens de tomografia computadorizada de feixe cônico (TCFC) de 100 pacientes adultos (&#x2265; 20 anos), obtidas pelo aparelho i-CAT Classic®. Um examinador calibrado observou a presença dos CAS, CI e FI bilateralmente. Quando presentes, eram medidos comprimento (parte descendente, parte do assoalho da órbita e total), largura e altura do CI; altura, largura e distância ao rebordo inferior da órbita (RIO) do FI; distância da borda inferior dos CAS a crista do rebordo alveolar em 5 regiões: canino (CAN), primeiro pré-molar (1PM), segundo pré-molar (2PM), primeiro molar (1M) e segundo molar (2M); e os diâmetros dos CAS. Foram também observados a localização dos CAS em relação ao seio maxilar e a presença de reparos anatômicos como canal duplo/múltiplo, anastomose intra-óssea e extensão do CASA para a abertura piriforme. Associações entre homens e mulheres, lados direito e esquerdo e regiões foram investigadas para todas as medidas e visibilidade, utilizando separadamente os métodos estatísticos. A presença do CI e FI foi de 100%. A visibilidade do CASA/CASP foi de: 99%/0% (CAN), 99%/21% (1PM), 89%/41% (2PM), 46%/44% (1M) e 7%/61% (2M). As médias dos comprimentos da parte descendente, da parte do assoalho da órbita e total do CI foram de 8,82mm, 19,44mm e 28,35mm, respectivamente. Altura e largura médias do CI foram, respectivamente, 2,08mm e 3,91mm. As médias da altura, largura e distância ao RIO do FI foram: 4,43mm, 5,18mm e 7,52mm, respectivamente. As distâncias médias do CASA ao rebordo alveolar foram: 18,54mm (CAN), 25,47mm (1PM), 28,43mm (2PM), 30,78mm (1M) e 33,21mm (2M); e do CASP: 22,3mm (1PM), 17,65mm (2PM), 15,34mm (1M) e 16,87mm (2M). As médias dos diâmetros do CASA e do CASP foram 0,90mm e 0,83mm, respectivamente, sendo que 77,5% dos CASA e 82% dos CASP eram &#x2264; 1mm e 22,5% dos CASA e 18% dos CASP eram entre 1-2 mm. Em relação ao seio maxilar, 53% e 44% dos CASA foram encontrados no terço superior e médio, respectivamente, e 64% e 36% dos CASP foram encontrados no terço inferior e médio, respectivamente. Houve diferença estatisticamente significativa (p<0,05) entre homens e mulheres para o comprimento, altura e largura do CI; para a altura, largura e distância ao RIO do FI; e para as distâncias dos CAS ao rebordo alveolar. CASA duplo, anastomose intra-óssea e extensão do CASA para a abertura piriforme foram detectados em 24,5%, 38,5% e 84% dos casos, respectivamente. A localização da anastomose foi teve maior ocorrência entre o CAN e 1PM (43%). Os resultados sugerem que a TCFC seja uma ferramenta adequada para examinar os CAS, CI e FI no planejamento de procedimentos cirúrgicos do terço médio da face, a fim de evitar danos a estruturas neurovasculares importantes. / To provide more information to clinicians in planning maxillofacial surgical interventions, the present study evaluated the presence, location and size of the superior alveolar canals (SAC), anterior (ASAC) and posterior (PSAC), infraorbital canal (IC) and infra-orbital foramen (IF) in cone beam computed tomography (CBCT) of 100 adult patients (&#x2265; 20 years old), obtained by i-CAT Classic®. One calibrated examiner observed SAC, IC and IF presence, bilaterally. When present, were measured: length (descending part, orbital floor part and total), width and height of the IC, height, width and distance from the IF to the inferior orbital rim (IOR), distance from the lower border of SAC to the alveolar crest in 5 regions: canine (CAN), first premolar (1PM), second premolar (2PM), first molar (1M) and second molar (2M); and the diameters of SAC. It was also observed the location of SAC in relation to the maxillary sinus floor and the presence of anatomical landmarks such as doble/multiple canal, intraosseous anastomosis and ASAC extension to the piriform aperture. Associations between men and women, right and left sides and regions were investigated for all measurements and presence using statistical methods separately. The presence of the IC and IF was 100%. The presence of ASAC/PSAC was: 99%/0% (CAN), 99%/21% (1PM), 89%/41% (2PM), 46%/44% (1M) e 7%/61% (2M). The mean lengths of the IC descending part, IC orbital floor part and total lenght of the IC were 8.82mm, 19.44mm and 28.35mm, respectively. The mean height and width of the IC were, respectively, 2.08mm and 3.91mm. The mean height, width and distance to the IOR of IF were: 4.43mm, 5.18mm and 7.52mm, respectively. The mean distances of ASAC to the alveolar crest were: 18.54mm (CAN), 25.47mm (1PM), 28.43mm (2PM), 30.78mm (1M) and 33.21mm (2M); and of PSAC: 22.3mm (1PM), 17.65mm (2PM) 15.34mm (1M) and 16.87mm (2M). The mean diameters of ASAC and PSAC were 0.90mm and 0.83mm, respectively, and that, 77.5% of ASAC and 82% of PSAC were &#x2264; 1mm and 22.5% of ASAC and 18% of PSAC were between 1-2 mm. In relation to the maxillary sinus, 53% e 44% of the ASAC were found in the upper and middle third of maxillary sinuses, respectively, and 64% and 36% of the PSAC were found in lower and middle third, respectively. There was a statistically significant difference (p<0.05) between men and women for the length, height and width of the IC, for the height, width and distance to the IOR of IF, and for distances of SAC to the alveolar crest. Double ASAC, intraosseous anastomosis and ASAC extension to the piriform aperture were present in: 24.5%, 38.5% and 84% of the cases, respectively. The location of the anastomosis had more incidence between the CAN and 1PM (43%). The results suggest that CBCT is a suitable tool to evaluate the SAC, IC and IF, assisting surgeons in planning surgical procedures of the midface, in order to avoid damage to important neurovascular structures.
80

Estudo do efeito da radiação ionizante na utilização dos catalisadores desativados de craqueamento / Study of the effect of ionizing radiation for utilization of spent cracking catalysts

Kondo, Fernando Mantovani 09 December 2014 (has links)
Catalisador é uma substância que altera a velocidade de uma reação. Na indústria do petróleo os catalisadores mais utilizados são os catalisadores de Fluid Catalytic Cracking (FCC) e Hidrocatalytic Cracking (HCC) cada qual utilizado em uma determinada etapa do processo. Esses catalisadores são usados para facilitar a quebra das cadeias moleculares que darão origem a uma mistura de hidrocarbonetos. Contudo, o catalisador perde progressivamente sua atividade, seja pela mudança de sua estrutura molecular original ou pela sua contaminação provenientes de outras moléculas do petróleo. A aplicação das radiações ionizantes (feixe de elétrons e raios gama) nesses catalisadores desativados foi estudada para auxiliar na extração de metais ou terras-raras de alto valor agregado. Nos ensaios realizados com os catalisadores de FCC utilizaram-se das técnicas de irradiação por 60Co e por feixe de elétrons (EB) e tiveram como estudo a extração do lantânio (La2O3), a regeneração e utilização desses catalisadores. Entretanto, o uso da radiação ionizante não contribuiu nesses processos. Já nos catalisadores de HCC foi utilizado a irradiação por feixe de elétrons e como estudo a extração do molibdênio (MoO3). Na temperatura em torno de 750°C nesses catalisadores irradiados do leito inferior obteve-se um rendimento de extração duas vezes maior em comparação aos não irradiados, ou seja de 57,65% e 26,24% respectivamente. / Catalyst is a substance that changes the rate of a reaction. In the petroleum industry the commonly catalysts are used for Fluid Catalytic Cracking (FCC) and Hidrocatalytic Cracking (HCC), which one applied in a specific stage. These catalysts are used to facilitate the molecular chains cracking which will generate a mixture of hydrocarbons. However, the catalyst gradually loses its activity, either by changing its original molecular structure or by its contamination from other petroleum molecules. The application of ionizing radiation (electron beam and gamma rays) over these spent catalysts was studied to contribute with the extraction of metals or rare-earths of high added-value. Tests carried out with FCC catalysts were used the techniques of 60Co irradiation and electron beam (EB) and had as a subject the extraction of lanthanum (La2O3), regeneration and utilization of these catalysts. However, the use of ionizing radiation has not contributed in these processes. Meanwhile with HCC catalysts the irradiation used was electron beam and had as a subject the extraction of molybdenum (MoO3). In temperature around 750°C, these irradiated catalysts of the lower region have an extraction yield twice higher compared to non-irradiated ones, in other words 57.65% and 26.24% respectively.

Page generated in 0.0506 seconds