• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 41
  • 1
  • 1
  • Tagged with
  • 44
  • 44
  • 30
  • 21
  • 18
  • 17
  • 17
  • 16
  • 15
  • 15
  • 14
  • 12
  • 12
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Influência da aplicação de um inibidor de metaloproteinases na resistência da união adesiva à dentina radicular

Leitune, Vicente Castelo Branco January 2010 (has links)
O objetivo do presente estudo foi avaliar o efeito da aplicação de clorexidina após o condicionamento ácido na preservação da camada híbrida, avaliando a resistência de união imediata e a longo prazo de pinos de fibra de vidro cimentados à dentina radicular. Setenta e dois dentes unirradiculares superiores humanos foram selecionados. Os canais radiculares foram alargados para receberem os pinos de fibra de vidro e aleatoriamente divididos em três grupos (n=24). No Grupo Controle (Gcontrol), o pino de fibra de vidro foi cimentado de acordo com as instruções do fabricante, utilizando um sistema adesivo convencional de três passos e um cimento resinoso dual. Os grupos tratados com digluconato clorexidina GCHX0.2 e GCHX2 receberam a aplicação de solução de clorexidina 0,2% e 2%, respectivamente, após o condicionamento com ácido fosfórico e os pinos foram cimentados utilizando o mesmo sistema adesivo e cimento utilizados no Gcontrol. As raízes foram seccionadas transversalmente ao longo eixo do dente, em fatias de 0,68 (± 0,09) mm. Metade dos dentes foi submetida ao ensaio de push-out após 24 horas e a outra metade, após seis meses de armazenamento em água destilada, a 37°C. Os valores foram analisados com ANOVA de duas vias e teste de comparações múltiplas de Tukey, com nível de significância de 5%. A aplicação de clorexidina não influenciou a resistência de união quando os dentes foram avaliados no mesmo período de armazenagem (p>0,05). O tempo de armazenamento diminuiu significativamente a resistência de união de 24 horas para 6 meses, em todos os grupos (p<0,05). A aplicação de clorexidina não preveniu significativamente a degradação da resistência de união de pinos de fibra cimentados em raízes de dentes humanos, após seis meses de armazenamento. / Introduction: This study evaluated the effect of chlorhexidine applied after dentin phosphoric acid etching on hybrid layer preservation, analyzing the immediate and long-term bond strength of a fiber post cemented to root dentin. Methods: Seventy-two single-rooted, human upper teeth were selected for analysis. Root canals were enlarged for fiber post cementation and were randomly divided into three groups (n= 24). After phosphoric acid etching, each group received a different dentin treatment. In the Control Group (Gcontrol), the fiber post was cemented according to the manufacture’s instruction, using a three-step etch-and-rinse adhesive and a dual-cured resin cement. The Chlorhexidine 0.2% Group (GCHX 0.2) and the Chlorhexidine 2% Group (GCHX 2) received an application of a chlorexidine digluconate solution of 0.2% and 2%, respectively, after phosphoric acid etching, and the post was cemented using the same adhesive and cement that was used in the Gcontrol. Teeth were sectioned transversally in slices of 0.68 (± 0.09) mm. Half of the teeth were submitted to push-out bond strength after 24 hours and the other half were submitted after six months of distilled water storage at 37°C. Data were analyzed by using the two-way analysis of variance (ANOVA) and a post hoc tests using the Tukey multiple comparison test at α = 0.05. Results: Chlorhexidine application had no influence on bond strength when teeth were stored for the same period of time (p>0.05). The storage time significantly decreased the bond strength values of 24 hours to six months, in all groups (p<0.05). Conclusion: After six months, chlorhexidine application did not effectively arrest bond strength degradation of fiber post cemented in human roots.
12

Influência de três sistemas adesivos na resistência à extrusão de pinos de fibras de vidro fixados com um cimento resinoso / Influence of three adhesives systems on the extrusion strength of glass fiber posts fixed by resin cements

Juliana Cefaly Raineri 03 May 2006 (has links)
Com o intuito de elevar os valores de resistência à fratura dos dentes que sofreram tratamento endodôntico, várias técnicas restauradoras têm sido desenvolvidas. Atualmente os sistemas de pinos de fibras de carbono e de vidro são os dispositivos mais utilizados, devido às suas vantagens de possuírem módulo de elasticidade próximo ao da dentina, o que causa menor estresse e conseqüentemente menor quantidade de fraturas radiculares, além de não necessitarem da fase laboratorial. A escolha do cimento utilizado para a cimentação desses pinos, tem grande importância e o advento dos cimentos resinosos e dos sistemas adesivos que com eles podem ser empregados, representam uma grande evolução em razão das possibilidades de se obter retenções micromecânicas no interior dos condutos. Assim, o objetivo deste estudo foi avaliar a resistência à extrusão de pinos de fibras de vidro cimentados com cimento resinoso Rely X ARC com a aplicação de três diferentes sistemas adesivos: Scotchbond, Single bond e Adper Prompt LPop. Após a cimentação os espécimes foram seccionados em duas regiões, apical e cervical, que constituía cada uma um corpo de prova. Para possibilitar a realização do teste de extrusão, utilizou-se um dispositivo de aço inoxidável que estabilizava o corpo de prova. Este dispositivo tinha um orifício central que permitia o deslocamento do pino ou do cimento, durante o teste de extrusão. Para o teste de extrusão o corpo de prova foi adaptado no dispositivo com a face cervical voltada para baixo e uma ponta ativa com extremidade plana (1mm de diâmetro) foi adaptada à máquina de ensaios universal que exercia uma força de extrusão o mais próximo possível do centro do pino. O teste foi realizado com um deslocamento de 0,5mm por minuto, onde a carga máxima de falha foi registrada em kgf. No que diz respeito ao cimento resinoso Rely X ARC, em combinação com os adesivos utilizados, os melhores resultados na região cervical da raiz foram obtidos com o cimento Rely X com o sistema adesivo Scotchbond, seguido pelos sistemas Adper Prompt e Single bond. Na região apical o Scotchbond foi melhor que o Adper Prompt e o Single bond, mas não houve diferença estatisticamente significante entre o Adper Prompt e Single bond. / In order to increase strength to fracture of endodontically treated teeth, a number of restorative techniques were developed. Nowadays, carbon and glass fiber post systems are the most used due to their advantages of modulus of lasticity similar to dentin, which lead to lower stress and consequently lower number of root fractures, besides no laboratorial work is needed. The choice of the best cement for luting these posts is an important step and the development of resin cements and adhesive systems that can be use with posts are a great evolution due to the possibility of micromechanical retention in roots. Therefore, the aim of this study was to evaluate extrusion strength of glass fiber posts cemented with resin luting cement Rely X ARC using three different adhesive systems: Scothbond, Single bond and Adper Prompt L Pop. After luting, samples were seccionated in two regions, apical and cervical, each one representing one sample. A stainless steel device was used to perform extrusion test, stabilizing samples. This device had a central orifice that allowed movement of post or cement, during extrusion test. For extrusion test, sample was adapted in the device with cervical face directed to down and a plane surface active point (1 mm diameter) was adapted to the universal test machine which exerted an extrusion force in the center of post. Test was performed with 0.05 mm per minute and the maximum load at failure was registered in kgf. Regarding resin luting cement Rely X ARC combining with adhesive systems, the best results at cervical were obtained with Rely X and Scotchbond adhesive, followed by Adper Prompt and Single bond systems. At apical region Scotchbond was better than Adper Prompt and Single bond, but there was no statistically significant difference between Adper Prompt and Single bond.
13

Efeito de diferentes tratamentos de superfície de pinos de fibra de vidro na resistência adesiva de um cimento resinoso autoadesivo / Effect of different surface treatment of glass fiber post in bond strength between dentin intraradicular and selfadhesive resin cement

Borges, Marciano de Freitas 15 July 2016 (has links)
The objective of the present study was to evaluate the bond bond strength of intraradicular glass fiber post submitted to different surface treatments and cemented on the root dentin with resin cement adhesive. 40 straight roots of upper incisors extracted for clinical purposes were used in this research (without treatment, silane, 35% hydrogen peroxide, sodium bicarbonate). The post were cemented with resin cement adhesive relyx U200. Twenty four hours after cementing the post, the root were cut crosswise so then producing 1,0 mm inch specimens. The specimens in the format of hourglass were submitted to microtensile tests in order to obtain the amounts of adhesive strength and also to verify the fracture pattern. Two samples of the control group were prepared for analysis using scanning electron microscopy in order to map the adhesive interface. After data collecting, the samples were submitted to ANOVA and test of Tukey statistical analysis. Therefore, these tests were verify differences in the bond strength and allow descriptive analysis of adhesive interface. There was a statistically significant different between the different glass fiber post surface treatments C, Sil, Per and Bic (p = 0.0018 <0.05). There was a statistically significant different between the regions of root dentin (p = 0.0034 <0.05), respectively, coronal region - (19.1 (± 3.71), 25.6 (± 4.3), 24.4 (± 3.16); 30.2 (± 13.0) - showed the highest bond strength values that the root middle third (14.6 (± 4.6), 12.5 (± 5.0), 10.6 (± 3.3), 10.87 (± 2:48). Within the limits of experimental procedures, it can be concluded that treating the surface of the fiber post with chemical and physical agents increases the bond strength of glass fiber post for independent of root dentin canal. / Este estudo avaliou a resistência de união de pinos intraradiculares submetidos a diferentes tratamentos de superfície e cimentados com cimento resinoso autoadesivo à dentina radicular. Foram utilizados na pesquisa 40 raízes retas de caninos superiores, extraídos por motivos clínicos. Os dentes foram divididos aleatoriamente em 4 grupos, de acordo com o tratamento de superfície do pino (Sem tratamento (C), Silano (Sil), Peróxido de Hidrogênio 35% (Per), Bicarbonato de Sódio (Bic). Os pinos foram cimentados com o cimento resinoso autoadesivo RelyX U200. Vinte e quatro horas após a cimentação dos pinos, as raízes foram cortadas transversalmente de forma a produzir espécimes de espessura de 1,0 mm. Os espécimes em forma de ampulheta foram submetidos ao teste de micro-tração para obtenção de valores de resistência adesiva e verificação do padrão de fratura. Duas amostras do grupo controle foram preparadas para análise em microscopia eletrônica de varredura para mapeamento da interface adesiva. Após a coleta dos dados, os mesmos foram submetidos a análise estatística ANOVA e teste de Tukey para verificação de diferenças de resistência adesiva e análise descritiva para interface adesiva. A análise de variância acusou diferença estatisticamente significante entre os diferentes tratamentos de superfície do pino de fibra de vidro - C, Sil, Per e Bic (p= 0.002 ). Houve diferença estatisticamente significativa entre as regiões da dentina radicular, (p=0.003), sendo que a região cervical (19.1 (±3.71); 25,6 (±4.03); 24.4 (±3.16); 30.2 (±13.0)) mostrou os maiores valores que no terço médio radicular (14.6 (±4.6); 12.5 (±5.0); 10.6 (±3.3); 10.87(±2.48)). Dentro das limitações dos procedimentos experimentais, pode ser concluído que o tratamento da superfície dos pinos de fibra com agentes químicos e físicos, aumenta a resistência de união de pinos de fibra de vidro à dentina radicular no terço cervical.
14

Resistencia ao cisalhamento por extrusão - "push out" - de pinos de fibra de vidro a dentina intra-radicular

Cordeiro, Nara Pereira d'Abreu 03 December 2003 (has links)
Orientadores: Mario Fernando de Goes, Luis Roberto Marcondes Martins / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T15:59:52Z (GMT). No. of bitstreams: 1 Cordeiro_NaraPereirad'Abreu_D.pdf: 3561839 bytes, checksum: 125cbc91719d6a902ce59502debf7873 (MD5) Previous issue date: 2003 / Resumo: o objetivo deste estudo foi avaliar a resistência ao cisalhamento por extrusão (push out) entre a dentina intra-radicular e pinos de fibra de vidro nas regiões cervical, média e apical de raízes utilizando dois sistemas de cimentação adesiva. Foram selecionados vinte pré-molares inferiores unirradiculares recém extraídos por motivos ortodônticos, hígidos e livres de trincas. As coroas dos dentes foram removidas na altura da junção cemento esmalte. As polpas dentais foram removidas através de limas endodônticas e os condutos radiculares foram preparados com brocas de largo nO 5, com 8,Omm de penetração. As raízes foram divididas em dois grupos de 10: Grupo 1- pino fixados com o sistema adesivo autocondicionante ED Primer e cimento resinoso Panavia F; Grupo 2- pinos fixados com o sistema adesivo de frasco único Single Bond e cimento resinoso Rely X. Após a fixação dos pinos, as raízes foram mantidas em estufa a 37°C, por 24 h. A porção mais apical das raízes foi seccionada até a altura em que a raiz apresentasse 8,Omm de comprimento. Em seguida, as raízes foram seccionadas transversalmente e 3 discos de 2,7mm de altura foram obtidas e classificadas segundo a região cervical, média e apical do pino. O ensaio de resistência de união por extrusão foi realizado em máquina de ensaio universal Instron 4411 onde uma haste metálica com ponta ativa de 1,Omm de diâmetro produziu a carga para efetuar o deslocamento do pino do conduto radicular. Os valores médios de resistência de união por extrusão não apresentaram diferenças estatísticas significantes no terço cervical da raiz entre os dois materiais de fixação avaliados. Nas regiões média e apical do conduto, os valores de resistência de união apresentados pelo Sing/e Bond + Re/y X foram superiores e estatisticamente diferentes em relação aos valores apresentados pelo sistema ED Primer + Panavia F (p< 0,05). Para os dois materiais em estudo, não houve diferença estatística quando comparadas as regiões média e cervical do pino, porém apresentaram diferença estatística em relação à região apical (p< 0,05). Após o ensaio de cisalhamento por extrusão, os espécimes foram seccionados no sentido longitudinal para análise em microscopia eletrônica de varredura. A zona de interdifusão adesivo/dentina produzida pelo adesivo de frasco único Sing/e Bond apresentou-se mais espessa do que a zona de interdifusão apresentada pelo adesivo autocondicionante ED Primer. Houve áreas desmineralizadas com presença de túbulos dentinários abertos porém parcialmente preenchidos pela resina em ambos os grupos. Também foram observadas bolhas que variaram de tamanho e forma na camada de cimento junto à área da interface de união e mais constantes no terço apical das raízes. Palavras-chave: pino de fibra de vidro; cimento resinoso; sistema adesivo; resistência de união; "push out / Abstract: The purpose of this study was to evaluate the bond strength between fiber posts cemented in root dentin considering different depths of the roots (cervical, median and apical) and two luting materiais, through push out tests and to examine the integration among these components through scanning electron microscopy. Twenty sound bicuspids, tree trom cracks, extracted for orthodontic reasons, were selected. The crowns were removed at the cement enamel junction. The pulps were removed with endodontic reamers and the first 8,Omm of the canais were shaped with number 5 largo burs. The roots were divided into two groups of 10 each. The roots trom group 1 received fiber posts cemented with the self etching primer ED Primer and the composite resin Panavia F., while the roots of Group 2 received fiber posts cemented with the one bottle adhesive Single Bond and the composite resin Rely X. After the posts cementation, the roots were kept in humidity at 3-,0 C for 24 hours. The most apical part of the roots were sectioned until they were 8.0mm long. After that, the roots were sectioned transversally and three 2.7mm thick sections were obtained: cervical, median and apical. The push out test that evaluated bond strength between luting material and root dentin was carried out on an Instron (4411) testing machine. The specimens were positioned on a steel support platform with the post centered over a 2.0mm hole in the platform. A steel probe 1.0mm in diameter was centered over the post and used to apply force to the test specimens. Data from the push out test revealed no statistically significant differences at the cervical portion of the root between the two cementation systems tested. At the median and apical portion of the root, the bond strength values presented by the Sing/e Bond and Re/y X were superior and statistically different from those presented by ED Primer and Panavia F (P<O,05). After the push out test, the specimens were sectioned longitudinally for observation in scanning electron microscope. Afterwards, the specimens were gold sputtered to have their failure mode evaluated. The adhesive/dentin hybrid layer formed by the one bottle adhesive Sing/e Bond was thicker than the one formed by the self etching ED primer. There were zones of demineralization in the root dentin not filled with the adhesive for both groups. Many voids could be observed at the cernent layer close to the bonding area and they seemed to be more frequent at the apical portion of the roots / Doutorado / Dentística / Doutor em Clínica Odontológica
15

Effect of resin cement, aging process and root level on the bond strength of the resin-fiber posts

Almulhim, Khalid 01 January 2014 (has links)
Background . Little is known about the long-term clinical bonding effectiveness of the Fiber-reinforced composite (FRC) posts cemented with self-etch adhesive systems. Bond stability and longevity of the cemented post are adversely affected by physical and chemical factors over time, such as expansion and contraction stresses caused by thermal changes and occlusal load. This clinical condition can be simulated in vitro by thermocyclic loading; and bonding effectiveness can be evaluated by applying the micropush out test. Therefore, more in vitro studies are needed to evaluate the bond strength of the fiber posts cemented with different resin cement systems after simulating the artificial aging induced by thermocycling. The aim of this study was to compare the microtensile bond strength of two different resin cement systems (total etch, and self-etch resin cement system) used for cementation of fiber reinforced composite posts in three different aging periods using thermocycling. Methods . Following IRB approval, sixty freshly extracted bicuspid single rooted natural teeth were endodontically treated, and the post-spaces were prepared to receive a fiber-post cemented with either a total etch resin cement (Rely-X Ultimate) or with a self-etch resin cement (Rely-X Unicem). No thermocycling, 20,000 and 40,000 cycles was used to age the specimens. Teeth were randomly allocated into six different groups: G1 - Control: Rely-X Ultimate cement with no thermocycling. G2: Rely-X Ultimate cement with 20,000 thermocycling. G3: Rely-X Ultimate cement with 40,000 thermocycling. G4: Rely-X Unicem cement. G5: Rely-X Unicem cement. G6: Rely-X Unicem cement. Microtensile bond strength determined using a micropush out test on a universal testing machine (MTS). Additionally, the failure mode of each specimen was observed under a stereomicroscope (Olympus) at 40x magnification. Finally, one representative sample was randomly selected from each of the five failure modes for scanning electron microscope (SEM) examination of the surface morphology in order to obtain SEM images of the failure patterns at 29-70x magnifications. Statistical analysis: Nested general linear and generalized linear model was created to look for statistical significance. Level of significance was set at P < 0.05. Results . No significant differences were found on the bond strength between the two types of resin cement systems (total etch and self-etch). Regarding the thermocycling effect, the bond strengths of the group of 40,000 cycles was significantly lower than the 20,000 cycle group. In addition, the bond strengths of the specimens collected from the coronal third of the root were significantly lower than the specimens from the apical third. A Fisher's Exact test was applied to evaluate the failure mode differences, and showed statistically significant differences between the groups. Conclusions . The bond strength to the root canal dentin did not vary with the type of resin cement systems (total-etch vs self-etch). The microtensile bond strength values of FRC posts were significantly affected by increasing the thermocycling, and were significantly different among the different longitudinal levels of the root canal.
16

Utilização do ácido ascórbico como tentativa de reverter o efeito da desproteinização com hipoclorito de sódio na dentina radicular, utilizando diferentes sistemas de cimentação / Redox potencial of ascorbic acid after sodium hypochlorite deproteinization to root dentine with different adhesive systems

Cunha, Leonardo Fernandes da 06 April 2009 (has links)
O objetivo deste trabalho foi avaliar o efeito da aplicação de ácido ascórbico após a desproteinização da dentina radicular, utilizando um cimento auto-adesivo e comparando-o a outros dois sistemas adesivos. Possíveis diferenças de união adesiva entre os terços radiculares também foram avaliadas. Quarenta e cinco raízes de incisivos bovinos foram divididas em três grupos, conforme o tratamento da raiz: irrigação com soro fisiológico; desproteinização com NaOCl (5%) por 10 minutos; irrigação com NaOCl por 10 min seguida da aplicação de ácido ascórbico por 10 min. O cimento autoadesivo Rely X U100 foi utilizado para cada um dos grupos citados. O cimento Rely X ARC foi utilizado com outros dois adesivos, para efeito de comparação: Single Bond e Clearfil SE Bond. Os espécimes foram armazenados em água destilada por 24 horas e testados quanto à resistência à extrusão (push-out). Os resultados foram submetidos ao teste ANOVA a três critérios e Dunnet T3 (=0.05). Não foram encontradas diferenças estatisticas entre os materiais utilizados. A desproteinização resultou em resistência adesiva diminuída, enquanto o tratamento subsequente com ácido ascórbico foi capaz de devolver a resistência adesiva em valores semelhantes aos do grupo controle. Diferenças entre os terços radiculares foram encontradas na seguinte sequência: coronal>médio>apical. O cimento auto-adesivo utilizado se comportou da mesma forma que os demais sistemas adesivos. O ácido ascórbico foi capaz de reverter o efeito de oxidação causado pela desproteinização. / The aim of this study was to evaluate the effect of ascorbic acid after root dentin treatment with sodium hypochlorite. A self-adhesive cement was compared with other two adhesive systems. The bond strength was also evaluated at different depths (coronal, middle, apical). Forty five single-rooted standard bovine teeth were divided in three groups. Specimens in each group were treated as follows: irrigation with physiologic serum; with NaOCl (5%) for 10 min; with NaOCl for 10 min and ascorbic acid for 10 min. The self-adhesive cement Rely X U100 was used for each one of the mentioned groups. The cement Rely X ARC was used with other two adhesives (Single Bond and Clearfil SE Bond). Specimens were stored in distilled water for 24 hours. Push-out tests were performed by using a universal testing machine, and the data was statistically analyzed (analysis of variance [ANOVA] and Dunnet T3; P < .05) A significant difference was not found among the materials tested. The deproteinization resulted in reduced bond strengths; though the subsequent treatment with ascorbic acid was capable to return the bond strengths. Differences among the region of post space were found: coronal>middle>apical. The ascorbic acid was capable to reverse the oxidation effect of the dentin deproteinization; the self-adhesive cement was similar to the other systems tested.
17

Avaliação in vitro da resistência de união à tração de três tipos de pinos de fibra cimentados a raízes bovinas com diferentes cimentos resinosos / In vitro evaluation of tensile bond strength of three types of fiber posts luted in bovine roots with different resin cements

Quintero, Mayra Zamboni 20 September 2012 (has links)
Este estudo teve como objetivo avaliar, através de testes de tração, a resistência de união de pinos pré-fabricados, com diferentes graus de translucidez, à dentina bovina, utilizando três tipos de cimentos resinosos. Noventa incisivos bovinos tiveram suas coroas anatômicas separadas das raízes através de uma secção perpendicular ao longo eixo dos dentes na junção amelocementária, de modo que as raízes apresentassem 14 mm de comprimento. Os condutos radiculares foram tratados endodonticamente e os espécimes, mantidos em água destilada a 37°C por 7 dias. Após esse período, foi realizada a desobturação de 7 mm de profundidade de cada conduto para a cimentação dos três tipos de pino: Exacto (Angelus), translúcido; Reforpost fibra de vidro (Angelus), branco; e Reforpost fibra de carbono (Angelus), negro e opaco. Três tipos de cimentos resinosos foram utilizados de acordo com as recomendações dos fabricantes: o cimento dual auto-adesivo Rely X U100 (3M ESPE); o cimento dual Rely X ARC (3M ESPE), associado ao sistema adesivo autopolimerizável Scotchbond Multi-Uso Plus (3M ESPE); e o cimento de ação exclusivamente química Cement Post (Angelus), associado ao sistema adesivo Fusion Duralink (Angelus), constituindo 9 grupos experimentais (n=10). Após a armazenagem dos corpos de prova em água destilada a 37º C por 7 dias, foi realizado o teste de tração no aparelho de ensaio mecânico da marca Kratos Equipamentos, a uma velocidade de 0,5mm/min até a ruptura dos mesmos. Para determinar a tensão de tração, foi calculada a área de adesão de cada espécime. Os dados foram analisados estatisticamente através da Análise de Variância e do teste de Kruskal-Wallis, com grau de significância de 5%. Os espécimes foram examinados através de um microscópio óptico Olympus (Tokyo, Japão), com 20x de aumento, para avaliação do modo de fratura. Em relação às variáveis estudadas, verificou-se que: o pino Exacto, com maior translucidez e maior conicidade, apresentou valores de resistência à tração significativamente inferiores do que os pinos Reforpost Fibra de Vidro e Reforpost Fibra de Carbono, quando utilizado o cimento Rely X ARC; o cimento dual auto-adesivo Rely X U100 apresentou menores valores de resistência à tração do que cimento dual Rely X ARC quando utilizados os pinos Reforpost Fibra de Vidro e Reforpost Fibra de Carbono; e o cimento de polimerização química Cement Post apresentou menores valores de resistência à tração em relação aos cimentos duais, independente do tipo de pino testado. Quanto à análise microscópica, observou-se que os cimentos resinosos aderiram mais aos pinos do que à dentina radicular. Portanto, a translucidez dos pinos não contribuiu para aumentar a resistência à tração dos cimentos resinosos duais em nenhum dos grupos testados. / This study aimed to evaluate, through tensile test, the bond strength of prefabricated posts with different degrees of translucency, using three types of resin cements. Ninety bovine incisors were selected and sectioned at the cemento-enamel junction. The root canals were endodontically treated and the specimens were stored in distilled water at 37°C for 7 days. After this period, a 7-mm-deep post space was prepared for the cementation of three types of posts: Exacto (Angelus), translucent; Fiberglass Reforpost (Angelus), white; and Carbon Fiber Reforpost (Angelus), black and opaque. Three types of resin cements were used according to manufacturers\' instructions: the self-adhesive dual cement Rely X U100 (3M ESPE); the dual cement Rely X ARC (3M ESPE), associated with autopolymerized adhesive system Scotchbond Multi-Uso Plus (3M ESPE), and the self-cured cement Cement Post (Angelus), associated with the autopolymerized adhesive system Fusion Duralink (Angelus), constituting nine experimental groups (n = 10). After the storage of the specimens in distilled water at 37°C for 7 days, the tensile test was performed with a universal test machine at a crosshead speed of 0.5 mm/min. To determine the bond strength, the bonding area of each specimen was calculated. The data were statistically analyzed by ANOVA followed by Kruskal-Wallis test, with a significance level of 5%. The dislodged posts were examined microscopically (Olympus; Tokyo, Japan) at x20 magnification to determine the type of failure. Regarding the variables studied, it was found that: the Exacto post, more translucent and tapered, had significantly lower tensile bond strength than Fiberglass Reforpost and Carbon Fiber Reforpost when used the dual cement Rely X ARC; the dual self-adhesive cement Rely X U100 showed lower tensile bond strength than the dual cement Rely X ARC, when used Fiberglass Reforpost and Carbon Fiber Reforpost; regardless of the type of post tested, the self-cured cement Cement Post had lower tensile strength compared to dual cements. It was observed microscopically that resin cements adhered more to the posts than to the root dentin. Therefore, the translucency of the posts had not contributed to increase the tensile strength of dual-curing resin cements in all groups tested.
18

INFLUÊNCIA DA TÉCNICA DE INSERÇÃO DE CIMENTOS RESINOSOS NA RETENÇÃO DE PINOS DE FIBRA DE VIDRO À DENTINA RADICULAR

Dobrovolski, Max 28 February 2012 (has links)
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2018-09-26T20:23:10Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Max_Dobrovolski.pdf: 3607607 bytes, checksum: 331e5e608402c91f04ea1641d53747a5 (MD5) / Made available in DSpace on 2018-09-26T20:23:10Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Max_Dobrovolski.pdf: 3607607 bytes, checksum: 331e5e608402c91f04ea1641d53747a5 (MD5) Previous issue date: 2012-02-28 / Este estudo teve como objetivo avaliar quatro técnicas de inserção de cimento resinoso na retenção de pinos de fibra de vidro à dentina radicular nos diferentes terços radiculares, bem como a nanoinfiltração nestes diferentes terços. As raízes de cinqüenta e dois pré-molares inferiores humanos extraídos foram tratadas endodonticamente e padronizado o preparo dos condutos. Assim, elas foram divididas aleatoriamente em quatro grupos, de acordo com a técnica de inserção do cimento: GC - seringa Centrix® com ponta fina; GL - broca Lentulo 35, GP - cimento aplicado diretamente no pino e GI - seringa para aplicação de insulina. Os pinos intra-radiculares (White Post DC - FGM) tiveram suas superfícies tratadas de acordo com o fabricante e foram cimentados de acordo com cada técnica. Após o armazenamento em água a 37° C por uma semana, para cada grupo, dez raízes foram seccionadas transversalmente em seis discos com 1 mm de espessura cada, e os terços coronário (TC), médio (TM) e apical (TA) do canal radicular foram identificados. O teste de push-out foi realizado a uma velocidade de 0,5 mm/min. Para avaliação da nanoinfiltração três raízes de cada grupo, ou seja, 6 discos por raiz, foram submetidos a imersão em Nitrato de Prata 50% para posterior obtenção de imagens feitas em microscopia eletrônica de varredura. As imagens foram analisadas por meio de software apropriado para obtenção das médias dos valores de nanoinfiltração convertidas em porcentagem. Os dados, submetidos a análise estatística por ANOVA 1 fator e Pós-teste Tukey (0,5%), mostraram que GC apresentou os melhores valores para resistência adesiva (MPa) e nanoinfiltração (%): 18,57 ± 4,19 e 37,70 ± 18,95 respectivamente, tendo GP o pior desempenho: 13,71 ± 1,61 e 65,11 ± 13,58 respectivamente. A técnica de inserção do cimento resinoso teve influencia nos valores de resistência adesiva e nanoinfiltração encontrados no estudo. / The aim of this study was to evaluate four techniques for insertion of resin cement on retention of glass fiber posts to root dentin in different root thirds, as well as these different nanoleakage in adhesive interface. The roots of the fifty-two human extracted pre-molars were endodontically treated and standardized preparation of the canals. It were divided into four groups according to the technique of insertion of the cement: GC - Centrix ® syringe with fine tip, GL - # 35 drill Lentulo, GP - cement applied directly to the post and GI - syringe for insulin delivery. The posts (White Post DC - FGM) had their surfaces treated in accordance with the manufacturer and were cemented according to each technique. After storage in water at 37° C for one week, each group of ten roots were sectioned transversely into six discs with 1 mm thick each, and coronal thirds (CT), medium (TM) and apical (TA) of root canal were identified. The push-out test was conducted at a speed of 0.5 mm / min. To evaluate the nanoleakage in the adhesive interface, three roots of each group, ie, 6 slices per root were submitted to immersion in 50% silver nitrate for subsequent obtaining of images made using scanning electron microscopy. Images were analyzed using appropriate software to obtain the mean nanoleakage values converted into percentage. The data were subjected to statistical analysis by ANOVA (one factor) and Tukey post-test (0.5%), showed that GC had the best values for bond strength (MPa) and nanoleakage (%):18,57 ± 4,19 e 37,70 ± 18,95 repectively and GP had the worst values: 13,71 ± 1,61 e 65,11 ± 13,58 respectively. The insertion technique of resin cement influenced on the bond strength values and on the nanoleakage found in the study.
19

Efeito da técnica úmida simplificada de adesão com etanol na cimentação intraradicular de pinos de fibra / Push-out bond strength and SEM evaluation of new bonding approach into the root canal

Carvalho, Carlos Augusto Ramos de 28 June 2011 (has links)
Este estudo avaliou a resistência ao deslocamento vertical push-out de pinos de fibra de vidro cimentados à dentina intra-radicular utilizando uma resina fluida padrão como agente cimentante em combinação com um adesivo dentinário experimental e um adesivo disponível comercialmente. 20 pré-molares unirradiculares humanos foram previamente extraídos e tratados endodonticamente. Os espécimes foram divididos em quatro estratégias de união a dentina: Grupo 1 com adesivo experimental com etanol na proporção em volume 1:1 (resina/etanol) e Grupo 2 com adesivo experimental com etanol na proporção em volume 1:2(resina/etanol); adesivos experimentais aplicados de acordo com a técnica úmida de adesão simplificada com etanol, Grupo 3: One-Step Plus aplicado de acordo com a técnica úmida de adesão simplificada com etanol; Grupo 4: One-Step Plus aplicado seguindo as instruções do fabricante. Os espécimes foram seccionados em fatias de 1 mm de espessura e apos o teste push-out foi realizado. Espécimes representativos foram selecionados para exame ultra-estrutural. Não houve diferença estatística na resistência ao deslocamento push-out entre as estratégias testadas de adesão (p> 0,05). O padrão predominante de fratura foi entre os pinos de fibra e o agente cimentante. A partir deste estudo devemos considerar como promissora a técnica com etanol utilizada na cimentação de pinos no canal radicular devido aos possíveis benefícios das resinas altamente hidrófobas. Mais estudos são necessários para validar o uso da técnica úmida de adesão simplificada com etanol quando cimentados pinos de fibra. / This study evaluated the push-out bond strength of glass fiber posts adhesively bonded to intraradicular dentin using a standard unfilled resin as luting agent in combination with an experimental and a commercially available adhesive. Twenty extracted single-rooted human teeth were endodontically treated. Specimens were assigned to 4 dentin bonding strategies: Group 1 (co-monomers to ethanol on ratio 1:1) and Group 2 (co-monomers to ethanol on ratio 1:2): Experimental adhesives applied in accordance with the simplified ethanol-wet bonding technique; Group 3: One-Step Plus (OSP) applied in accordance with the simplified ethanol-wet bonding technique; Group 4: OSP applied following manufacturers instructions. Bonded specimens were sectioned in 1-mm-thick slices and the push-out test was performed. Representative specimens were selected for ultrastructural examination. No statistical differences in push-out bond strength were found among the tested bonding strategies (p>0.05). The major failure pattern was between the post and the luting cement. From this study the ethanol technique should be considered as a promising approach in the luting of fiber posts into the root canal due to the possible benefits of highly hydrophobic resins. Further studies are needed to validate the use of the ethanol-wet bonding technique when luting a fiber post.
20

Fiber post-processing and atomic spectroscopy for the development of atomic-vapour photonic microcell / Post traitement de fibres creuses et spectroscopie atomique pour le développement de microcapsule photonique et atomique

Zheng, Ximeng 18 July 2017 (has links)
Cette thèse concerne la spectroscopie atomique pour le développement de microcellules photoniques à base de vapeur atomique alcaline (PMC). Le travail est motivé par reproduire les performances remarquables obtenues dans les domaines des références de fréquences et de l’optique cohérente en environnement laboratoire et à les transférer dans des dispositifs très compacts et autonomes accessibles à une communauté scientifique plus large ou à un marché commercial. Dans notre cas, ces futurs composants seront basés sur une fibre à cristal photonique à coeur creux (HC-PCF) remplie d'un matériau en phase gazeuse pour former la PMC et se distingue par une longueur d'interaction ultra longue associée à des dimensions modales transverses micrométriques. Cependant, cette échelle micrométrique du coeur creux de la fibre contenant les atomes soulève plusieurs défis techniques et scientifiques. Parmi les défis techniques, nous énumérons le développement d'un processus efficace pour le chargement d'atomes dans une telle fibre optique, la suppression ou l'atténuation de la réactivité physio-chimique des atomes (c'est-à-dire le rubidium) avec la surface interne silice entourant le coeur de la fibre, etc... En parallèle, le rapport large surface / volume du coeur de la fibre soulève des questions comme la dynamique de relaxation de la cohérence et la nature et l'effet de l'interaction atome-surface. Ainsi, les travaux de thèse reposent sur l’utilisation de revêtements spécifiques de la surface interne du coeur de la fibre avec différents matériaux pour atténuer ces réactions physico-chimiques, sur l'amincissement des larges coeurs creux des HC-PCF Kagomé à couplage inhibé et sur une technique de soudure qui garantit de faibles pertes d’insertion et l’absence de réactivité avec les atomes. Parallèlement, la thèse rapporte un ensemble d'expériences de spectroscopie pour évaluer la dynamique de relaxation des atomes à l'intérieur des HC-PCF et l’observation de nouvelles transparences sous-Doppler. / This thesis reported on atomic spectroscopy for the development of alkaline atomic vapor photonic microcell (PMC). The work is motivated by reproducing the outstanding laboratory environment based performances achieved in the fields of frequency standard and coherent optics in highly compact and stand-alone devices that can be accessible to a wider scientific community or to a commercial market. In our case these future devices will be based a Hollow-core photonic crystal fiber (HC-PCF) filled with a gas phase material to form a PMC, and outstands with an ultra-long long interaction length and micrometric modal area. However, the micrometric scale of the fiber core harboring the atoms raises several technical and scientific challenges. Among the technical challenges, we list the development of efficient process for atom loading inside long hollow fiber with small core diameter, the suppression or mitigation of physio-chemical reactivity of the atoms (i.e. Rubidium) with the fiber core inner-surface silica etc. In parallel, the large surface-to-volume ratio of the fiber-core raises questions like the coherence relaxation dynamics and the nature and effect of the atom-surface interaction. The thesis reports on fiber-core inner surface coating with different materials to mitigate the physio-chemical reactions of the confined atoms with the surface, on tapering large core inhibited coupling Kagome HC-PCF, and splicing technique that ensures low splice loss and no atomic reactivity during the splicing process. In parallel, the thesis reports on a set of spectroscopy experiments to assess the relaxation dynamics of atoms inside HC-PCF and to report on novel sub-Doppler transparencies.

Page generated in 0.0493 seconds