• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 135
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 135
  • 43
  • 34
  • 34
  • 32
  • 29
  • 28
  • 27
  • 25
  • 23
  • 20
  • 20
  • 20
  • 20
  • 20
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Verificação do estado limite de serviço de abertura das fissuras em seções de concreto armado submetidas à flexão simples

Leggerini, Maria Regina Costa January 2004 (has links)
Este trabalho apresenta um programa que tem por finalidade automatizar os procedimentos de verificação do estado limite de serviço de abertura das fissuras em seções retangulares e T de concreto armado, submetidas à flexão simples, conforme as recomendações da norma NBR 6118/2003 – Projeto de Estruturas de Concreto. O programa foi implementado na linguagem de programação Microsoft Visual Basic, aproveitando os recursos fornecidos por esta linguagem, que propiciam o desenvolvimento de uma entrada de dados amigável, típica do ambiente Windows. A fissuração, em elementos de concreto armado, ocorre quando as tensões de tração no concreto excedem a sua capacidade resistente. Nos elementos fissurados, as aberturas das fissuras devem ser controladas. Segundo as recomendações da norma, o valor característico da abertura das fissuras não deve ultrapassar determinados valores admissíveis. No procedimento implementado, são determinadas as aberturas das fissuras considerando-se o conjunto de barras da armadura tracionada e a camada mais tracionada da armadura, com o propósito de estabelecer a situação mais desfavorável. O programa tem também a pretensão de auxiliar estudantes de engenharia na compreensão do fenômeno da fissuração, fornecendo valores de elementos que caracterizam o funcionamento da peça fletida.
2

Caracterização de selantes resinosos contendo micropartículas poliméricas carregadas com clorexidina / Characterization of resin sealants containing polymer microparticles loaded with chlorhexidine

Nojosa, Jacqueline de Santiago January 2014 (has links)
NOJOSA, Jacqueline de Santiago. Caracterização de selantes resinosos contendo micropartículas poliméricas carregadas com clorexidina. 2014. 75 f. Dissertação (Mestrado em Odontologia) - Universidade Federal do Ceará. Faculdade de Farmácia, Odontologia e Enfermagem, Fortaleza, 2014. / Submitted by denise santos (denise.santos@ufc.br) on 2015-02-20T16:05:37Z No. of bitstreams: 1 2014_dis_jsnojosa.pdf: 1016330 bytes, checksum: 7e24f4b7901e5a6a6d997c7759de4938 (MD5) / Approved for entry into archive by denise santos(denise.santos@ufc.br) on 2015-02-20T16:09:29Z (GMT) No. of bitstreams: 1 2014_dis_jsnojosa.pdf: 1016330 bytes, checksum: 7e24f4b7901e5a6a6d997c7759de4938 (MD5) / Made available in DSpace on 2015-02-20T16:09:29Z (GMT). No. of bitstreams: 1 2014_dis_jsnojosa.pdf: 1016330 bytes, checksum: 7e24f4b7901e5a6a6d997c7759de4938 (MD5) Previous issue date: 2014 / Sealants represent a highly used measure in the prevention of caries and are indicated for patients at high risk for dental caries, especially when there is presence of teeth with deep, narrow and retentive fissures. Chlorhexidine (CHX) is a broad-spectrum antimicrobial agent that can bring benefits to sealants. This study will be presented in two chapters, whose objectives were: Chapter 1) To develop and characterize polymeric microparticles loaded with CHX; and Chapter 2) To evaluate the effect of incorporation of CHX, in free and microencapsulated forms, in the physicochemical properties of resin sealants. Material and methods: 1) Polymer microparticles of Poly(lactide-co-glycolide acid) (PLGA) loaded with diacetate (DA) and CHX digluconate (DG) were prepared using the spray drying technique and characterized in terms of stability, production yield, particle size, morphology, efficiency encapsulation (EE), drug loading (DL), cumulative release and antimicrobial response. 2) Two types of CHX (DA or DG), in respective free form 1 and 2%, or microencapsulated form 5 and 10% were added to the resin sealant with fluoride, Bioseal® (BI), or to the experimental sealant (EX) without fluoride. After obtaining the sealants formulations, tests were conducted to evaluate degree of conversion of the monomers, CHX release in dissolution media and fluoride release. Statistical analysis was performed by analysis of variance (ANOVA) Two-way, followed by Bonferroni post-hoc test. In all tests the level of confidence was 95% (p <0.05). Results: 1) The stability of drug in solution was detected for 50 days. The highest yield of production was observed with DA (over 71.56%). The particle size ranged from 1.01 to 3.07 µm, presenting homogeneous, spherical and non-aggregated microparticles. The microencapsulation process showed EE in the range of 4.42 to 36.67%, and DL between 0.26 and 4.07% amoung the formulations. It was observed a controlled release pattern. After the microbiological analysis, in vitro, DA and DG microparticles inhibited Streptococcus mutans. 2) In degree of conversion test, the mean values varied from the lowest DC for BI-PDG10 (69.74%) to the highest DC for EX-DG2 (77.69%). In the sealants containing free CHX (either DG or DA), the release was discrete from the first 6 h, except for EX-DG1 and EX-DA2 groups. In the experimental sealant, the highest release was detected in EX-PDA5 (22.91%), while EX-PDG5 (8.00%) and EX-PDG10 (8.99%) presented the lowest releases (p<0.001). In the fluoride release test, BI-DA1 showed the highest release when compared to the other sealants that contained free CHX (p<0.01). In the sealants containing CHX loaded PLGA-microparticles, the highest fluoride release was detected from BI-PDA5 (p<0.01). Conclusion: The characterization of microparticles loaded with CHX resulted in different release profiles. Addition of free or microencapsulated CHX into sealants affected the DC, depending on the type of CHX and sealant. Resin sealants containing free CHX released a large amount at the beginning of the study. Sealants containing microparticles showed a slow and gradual release. The fluoride release was higher in sealants that contained microparticles compared to the control. / Os selantes representam uma medida muito utilizada na prevenção de cárie e são indicados para pacientes de alto risco à cárie, especialmente, quando há presença de dentes com fissuras profundas, estreitas e retentivas. A clorexidina (CLX) é um agente antimicrobiano de amplo espectro, que poderia trazer benefícios aos selantes. Este estudo será apresentado em dois capítulos, cujos objetivos foram: Capítulo 1) Desenvolver e caracterizar micropartículas poliméricas carregadas com CLX; e Capítulo 2) Avaliar o efeito da incorporação de CLX, em suas formas livre e microencapsulada, nas propriedades físico-químicas de selantes resinosos. Material e métodos: 1) Micropartículas poliméricas de Poli(ácido láctico-co-glicólico) (PLGA) contendo diacetato (DA) ou digluconato de CLX (DG) foram preparadas, utilizando a técnica de secagem por pulverização, e caracterizadas em termos de estabilidade, rendimento de produção, tamanho da partícula, morfologia, eficácia de encapsulação (EE), carga do fármaco (CF), liberação cumulativa e resposta antimicrobiana. 2) Dois tipos de CLX (DA ou DG), nas respectivas formas livre a 1 e 2%, ou microencapsulada (PDA OU PDG) a 5 e 10%, foram incorporados ao selante resinoso com flúor, Bioseal® (BI), e ao selante experimental (EX) sem flúor. Após a obtenção das formulações dos selantes, realizaram-se testes de grau de conversão dos monômeros, avaliação da liberação de CLX em meios de dissolução e liberação de fluoreto. A análise estatística foi realizada por meio da análise de variância a dois critérios, seguida pelo teste de Bonferroni. Em todos os testes, utilizou-se o nível de confiança de 95% (p<0,05). Resultados: 1) A estabilidade do fármaco em solução ocorreu por 50 dias. O maior rendimento de produção ocorreu nas partículas contendo DA (mais de 71,56%). O tamanho das partículas variou de 1,01 a 3,07 µm, apresentando micropartículas homogêneas, esféricas e sem agregação. O processo de microencapsulação demonstrou EE de 4,42 a 36,67% e CF de 0,26 a 4,07% entre as formulações. Observou-se um padrão de liberação controlada e, após a análise microbiológica, in vitro, as micropartículas com DA e DG inibiram Streptococcus mutans. 2) No grau de conversão, a média dos valores obtidos variaram de 69,74% no grupo BI-PDG10 a 77,69% no EX-DG2. Nos selantes contendo DG e DA livre, a liberação de CLX foi discreta a partir de 6 h, exceto para os grupos EX-DG1 e EX-DA2. No selante experimental, a maior liberação ocorreu no grupo EX-PDA5 (22,91%), enquanto EX-PDG5 (8,00%) e EX-PDG10 (8,99%) apresentaram as menores liberações (p<0,001). No teste de liberação de fluoreto, BI-DA1 apresentou a maior liberação quando comparado aos outros grupos com CLX livre (p<0,01). Nos selantes contendo micropartículas carregadas com CLX, BI-PDA5 apresentou a maior liberação de fluoreto (p<0,01). Conclusão: A caracterização de micropartículas carregadas com CLX resultou em diferentes perfis de liberação. A adição de CLX livre ou microencapsulada nos selantes afetou o grau de conversão, dependendo do tipo de CLX incorporada e do selante. Grupos com CLX livre liberaram maior quantidade de fármaco no início do estudo. Selantes contendo micropartículas apresentaram liberação lenta e gradual. A liberação de fluoreto foi maior nos grupos com micropartículas comparado ao controle.
3

Verificação do estado limite de serviço de abertura das fissuras em seções de concreto armado submetidas à flexão simples

Leggerini, Maria Regina Costa January 2004 (has links)
Este trabalho apresenta um programa que tem por finalidade automatizar os procedimentos de verificação do estado limite de serviço de abertura das fissuras em seções retangulares e T de concreto armado, submetidas à flexão simples, conforme as recomendações da norma NBR 6118/2003 – Projeto de Estruturas de Concreto. O programa foi implementado na linguagem de programação Microsoft Visual Basic, aproveitando os recursos fornecidos por esta linguagem, que propiciam o desenvolvimento de uma entrada de dados amigável, típica do ambiente Windows. A fissuração, em elementos de concreto armado, ocorre quando as tensões de tração no concreto excedem a sua capacidade resistente. Nos elementos fissurados, as aberturas das fissuras devem ser controladas. Segundo as recomendações da norma, o valor característico da abertura das fissuras não deve ultrapassar determinados valores admissíveis. No procedimento implementado, são determinadas as aberturas das fissuras considerando-se o conjunto de barras da armadura tracionada e a camada mais tracionada da armadura, com o propósito de estabelecer a situação mais desfavorável. O programa tem também a pretensão de auxiliar estudantes de engenharia na compreensão do fenômeno da fissuração, fornecendo valores de elementos que caracterizam o funcionamento da peça fletida.
4

Verificação do estado limite de serviço de abertura das fissuras em seções de concreto armado submetidas à flexão simples

Leggerini, Maria Regina Costa January 2004 (has links)
Este trabalho apresenta um programa que tem por finalidade automatizar os procedimentos de verificação do estado limite de serviço de abertura das fissuras em seções retangulares e T de concreto armado, submetidas à flexão simples, conforme as recomendações da norma NBR 6118/2003 – Projeto de Estruturas de Concreto. O programa foi implementado na linguagem de programação Microsoft Visual Basic, aproveitando os recursos fornecidos por esta linguagem, que propiciam o desenvolvimento de uma entrada de dados amigável, típica do ambiente Windows. A fissuração, em elementos de concreto armado, ocorre quando as tensões de tração no concreto excedem a sua capacidade resistente. Nos elementos fissurados, as aberturas das fissuras devem ser controladas. Segundo as recomendações da norma, o valor característico da abertura das fissuras não deve ultrapassar determinados valores admissíveis. No procedimento implementado, são determinadas as aberturas das fissuras considerando-se o conjunto de barras da armadura tracionada e a camada mais tracionada da armadura, com o propósito de estabelecer a situação mais desfavorável. O programa tem também a pretensão de auxiliar estudantes de engenharia na compreensão do fenômeno da fissuração, fornecendo valores de elementos que caracterizam o funcionamento da peça fletida.
5

Avaliação clínica do tempo de permanência de um selante de fossas, cicatrículas e fissuras oclusais, sem ou com posterior aplicação tópica de flúor. / Clinical evaluation of the evaluation of the retention of sealant depending of sealant on the posterior application or non-application of fluoride after sealing.

Sgavioli, Claudia de Almeida Prado e Piccino 28 June 2000 (has links)
O processo carioso nas superfícies oclusais se inicia muitas vezes pelo acúmulo de microrganismos e nutrientes dentro das fossas, fissuras e cicatrículas. Sabe-se que com a utilização de fluoretos topicamente a incidência de lesões cariosas está diminuindo, contudo a porcentagem de cáries nas superfícies oclusais continua alta. Foi realizado o estudo da po-ssibilidade da combinação dos efeitos do flúor e dos selantes de sulcos, fossas, cicatrículas e fissuras, verificando-se o grau de permanência do selante resinoso fotopolimerizável Fluroshield (Caulk/Dentsplay, Milford) em dois grupos experimentais após uma única aplicação; grupo A- aplicando selante e imediatamente após aplicação tópica de flúor gel, e grupo B- somente selante. A amostra foi composta por 60 crianças, com idade entre 8 e 15 anos, que possuíam primeiros ou segundos molares permanentes inferiores sem evidência radiográfica de cáries interproximal e/ou oclusal. Os dois grupos de dentes selados pertencentes ao estudo passaram por quatro avaliações: imediatamente e após uma semana, 6 e 12 meses. Através da análise estatística dos resultados, pelo teste de GOODMAN136, em nível de 5% de significância, foi verificado que nas avaliações de 1 semana e 6 meses não houve diferença entre os dois grupos, já na de 12 meses houve predominância significante (p<0,05) da presença total de selante no grupo A, com aplicação de tópica de flúor gel. Não houve presença de cárie oclusal e interproximal nos molares selados, durante os 12 meses de avaliação. A associação da aplicação tópica de fluoreto acidulado com o selante aumenta o grau de permanência deste último e determina uma diminuição na incidência de cáries proximais. O selante apresentou-se efetivo, com 100,0% de permanência total e prevenção de cárie, depois de 1 ano, quando associado à posterior aplicação tópica de flúor. / The purpose of this clinical study was to evaluate the retention of FLUROSHIELD sealant material (Caulk/ Dentsply, Milford) in first and second molars, depending on the posterior application or non-application of fluoride after sealing. Sixty molars without evidence of clinical or radiographic caries, respectively, were selected from 60 patients (age 8 -15 years) for this study. The molars were randomly divided into 2 experimental groups (n=30): Group A: the teeth were sealed, and afterwards received an application of topical fluoride gel. Group B: the teeth were only sealed. The retention of the sealant material was evaluated 4 times: baseline, 1-week, 6-months and 1-year. The differences in the retention between the groups were calculated for significance using a GOODMAN test. The results showed 100% retention for Groups A and B at the 1-week and 6-month evaluations. Only the 1-year evaluation showed a significant prevalence of retention for the group using fluoride gel. No occlusal/interproximal caries were found on the sealed teeth. It was concluded that the association of sealing and fluoride can increase the retention of the sealant FLUROSHIELD and also decrease the incidence of interproximal caries.
6

Terapia das construções de concreto : metodologia de avaliação de sistemas epoxi destinadas a injeção de fissuras passivas das estruturas de concreto

Figueiredo, Enio Jose Pazini January 1989 (has links)
A perda do desempenho de uma edificação está associada ao aparecimento de patologias. A escolha de uma adequada terapia para os problemas encantrados, depende de um diagnóstico preciso do caso. A fissuração do concreto é alvo deste trabalho, por ser ela uma das manifestacoes patológicas mais incidentes nas edificacões, tanto a nível nacional como mundial. Nesse trabaho os diversos tipos de fissuras verificadas no concreto são agrupadas em ativas e passivas. Apresenta-se,H ainda, os materiais e técnicas de recuperacão para corrigir as fissuras dos dois grupos. Entre as soluções mais adotadas para recuperar as problemas patológicos, as que utilizam sistemas de base epóxi possuem destaque. O trabalho faz uma discussão sobre os fatores que influenciam o desempenho de sistemas epóxi destinados à injeção de fiissuras passivas do concreto e apresenta ensaios que podem ser realizados para garantir o sucesso da técnica. Ao final, apresenta um exemplo de avaliação de sistemas epóxi, encontradas no mercado nacional, destinados à injecão de fissuras e uma análise dos resultados obtidos. / The low of the performance in a building is associate with the failure appearing. The selection of a proper therapy for the problems diccovered, depends on an accurate diagnosys of the case. The purpose of this study is the concrete cracking, for it is one the most incident failures in buildings, as much in Brasil as abroad. ln this study, the several types of cracks observed in the concrete are grouped in active and passive. It is also presented materials and techniques for correcting the cracks of both groups. Among the most adopted solutions for repair failures, these which use epoxy resins, are remarcable. This study presents a discussion on the facturs that affect the performance of epoxy resins destined to the injection of concrete passive cracks, as well as tests that may be carried out to guarantee the technique success. At last, it prrsents an example of evaluation of epoxy resins found in the domestic market destined to injection of cracks and an analyses of the obtained results.
7

Estudo sobre modelos de fissuração de peças de concreto armado via método dos elementos finitos

D'Avila, Virgínia Maria Rosito January 2003 (has links)
o objetivo desta tese é apresentar dois modelos distintos para representar as fissuras em peças de concreto armado: um do tipo distribuído e outro do tipo incorporado. Os modelos de fissura incorporada se baseiam no conceito de descontinuidades incorporadas dentro do campo de deslocamento do elemento finito padrão. Já nos modelos de fissura distribuída a descontinuidade do campo de deslocamentos causada pela fissura é espalhada ao longo do elemento. O modelo distribuído proposto apresenta um diagrama tensão-deformação multilinear e sua calibragem é feita, segundo o Código Modelo CEB-FIP 1990, através de ensaios de tirantes de concreto armado. O modelo incorporado implementado é baseado no modelo de Dvorlcin, CuiMo e Gioia, o qual não inclui a contribuição da armadura no equilíbrio interno de forças do elemento. A inclusão da parcela da armadura é feita através de um modelo de transferência de tensão por aderência, conforme Russo, Zingone e Romano, Russo e Romano e FIE - Bulletin 10. Para representar o comportamento do concreto intacto, utiliza-se o modelo constitutivo de Ottosen. Trata-se de um modelo elástico não-linear, tridimensional, que utiliza valores secantes dos parâmetros do material. Já para simular o comportamento das barras de aço da armadura, emprega-se o modelo incorporado desenvolvido por Elwi e Hrudey. Neste modelo, permite-se uma disposição arbitrária das barras de aço no interior dos elementos de concreto. O modelo constitutivo adotado para a armadura é do tipo elasto-plástico com endurecimento. Por fim, alguns exemplos numéricos são analisados com o objetivo de comprovar a eficácia dos dois modelos propostos.
8

Fissuras em estruturas de concreto armado : análise das manifestações típicas e levantamento de casos ocorridos no Estado do Rio Grande do Sul

Dal Molin, Denise Carpena Coitinho January 1988 (has links)
Neste trabalho, para cada manifestação típica de fissuras em concreto armado, são apresentadas as possíveis causas e origens, os fenômenos intervenientes e seus mecanismos de ocorrência. É feita uma abordagem a respeito das consequências e efeitos da fissuração nas estruturas de concreto quanto à durabilidade, deformabilidade, estética e perda de estanqueidade. Apresenta-se uma aplicação prática a casos reais atendidos pela Fundação de Ciência e Tecnologia - CIENTEC, obtendo-se dados, tanto quantitativos como qualitativos, a respeito da incidência dos diferentes tipos de problemas ocorridos no estado do Rio Grande do Sul, no período de 1977 a 1986. Por fim, propõem-se medidas preventivas e corretivas adequadas a cada caso anteriormente discutido. / For every typical kind of cracking in reinforced concrete, are presented the probable causes and origins, the related phenomena and their mechanisms of occurences. An approach is made about the consequences and effects of cracking in concrete structures regarding durability, deformability, aesthetics and loss of watertightness. It is presented an actual application to real cases upon which CIENTEC (Fundação de Ciência e Tecnologia) has worked, resulting in data, qualitative and quantitative, about the incidence of different kinds of problems that have occured in Rio Grande do Sul from 1977 to 1986. ln the end, preventive and corrective actions are proposed for each case formely discussed about.
9

Influência da exposição do Biodentine ao tampão fosfato-salino sobre o selamento apical e a resistência de união à dentina (push-out)

Cechella, Bruna Casagrande January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2014. / Made available in DSpace on 2014-08-06T18:06:45Z (GMT). No. of bitstreams: 1 326186.pdf: 1067125 bytes, checksum: 23ea24549661f54c37be7e5a67aa2881 (MD5) Previous issue date: 2014 / Um novo material a base de silicato tricálcico (Ca3SiO5) - Biodentine foi lançado no mercado como alternativa ao MTA. Segundo o fabricante, é considerado um material reparador para diferentes situações clínicas. No entanto, não se tem conhecimento se, à semelhança do MTA, a capacidade de selamento e a resistência de união do Biodentine à dentina podem ser melhoradas após a interação com o tampão fosfato-salino (PBS). Assim, os objetivos deste estudo foram: i) avaliar e comparar, pelo método de infiltração de glicose, a capacidade de selamento proporcionada por plugs apicais de Biodentine e de MTA em um modelo ex vivo de apicificação, e ii) avaliar a influência da exposição e do tempo de contato ao tampão fosfato-salino (PBS) na resistência de união (RU) sob cisalhamento (push-out) do Biodentine à dentina. Para avaliação do selamento, o espaço do canal de 100 segmentos radiculares com 12 mm de comprimento foi alargado com brocas Gates-Glidden. Depois de realizada uma cavidade apical retrógrada e irrigação final com EDTA 17% seguido por NaOCl 1%, os segmentos radiculares foram aleatoriamente divididos em 4 grupos (n = 25) de acordo com o material utilizado na confecção do plug apical e o contato do plug com PBS: G1 - Biodentine; G2 - Biodentine + PBS intracanal; G3 - MTA e G4 - MTA + PBS intracanal. As aberturas cervicais foram seladas com Cimpat Rosa e os segmentos inseridos em uma esponja floral umedecida com PBS. Após 2 meses, os segmentos radiculares foram submetidos ao teste de infiltração de glicose sob pressão (103 KPa), durante 60 min. A concentração de glicose infiltrada foi determinada por um espectrofotômetro, e os dados analisados pelo teste qui-quadrado (p < 0,05). Para a avaliação da RU, 80 discos de dentina com 2 mm de espessura foram obtidos do seccionamento transversal de raízes de dentes humanos. O espaço do canal radicular foi alargado com brocas Gates-Glidden nos 2 a 5 para obter cavidades estandardizadas de 1,3 mm. As secções radiculares foram imersas em EDTA 17% seguido por NaOCl 1%, e secas. Após, o espaço do canal foi preenchido com Biodentine e os discos divididos em 2 grupos de acordo com o meio de armazenamento: G1 (n = 40): ambiente com algodão úmido; G2 (n = 40): PBS. Após 30 min, 1, 3 e 28 dias, 10 amostras de cada grupo foram submetidas ao teste push-out. Os dados foram analisados estatisticamente pelos testes ANOVA e Tukey (p < 0,05). Com relação ao teste de infiltração, traços de glicose foram observados em maior número de amostras que receberam o plug apical de Biodentine (p < 0,05). A exposição dos cimentos ao PBS intracanal não exerceu influência sobre o selamento. Em relação ao teste push-out, o contato com PBS proporcionou menores valores de RU (p < 0,05), exceto no período de 1 dia (p = 0,6017). Nas amostras do G1, a RU aumentou até 3 dias (p < 0,05). Nas amostras do G2, a RU aumentou no período de 30 min para 1 dia (p < 0,0001), e permaneceu estável até 3 dias (p = 0,9876). Aos 28 dias, foi observada uma queda significativa no valor de RU em ambos os grupos (p < 0,05). Foi possível concluir que o Biodentine apresentou uma capacidade de selamento inferior à do MTA; e, de maneira geral, sua RU aumentou gradativamente até 3 dias e diminuiu aos 28 dias. A exposição dos dois cimentos ao PBS não exerceu influência na sua capacidade de selamento e reduziu a RU do Biodentine à dentina.<br> / Abstract : A new material based on tricalcium silicate (Ca3SiO5) - Biodentine was launched in the market as an alternative to the MTA. According to the manufacturer, is considered a repair material for different clinical situations. However, it is not known if, like the MTA, the sealing ability and bond strength to dentin of Biodentine can be improved after interaction with phosphate-buffered saline (PBS). Then, the aim of this study were: i) to evaluate and compare, using a glucose leakage system, the sealing ability provided by apical plugs of MTA and Biodentine an ex vivo apexification model, and ii) to analyse the influence of exposure and time of contact of phosphate buffered saline (PBS) to Biodentine on the push-out bond strength (BS). To evaluate the sealing, the space of the canal of 100 root segments with about 12 mm long was shaped using Gates-Glidden. After created an apical retrograde cavity and final canal rinse with 17% EDTA followed by 1% NaOCl, the root segments were randomly divided into 4 groups (n = 25) according to the materials used to form the apical plug and the contact of the plug with PBS: G1 ? Biodentine; G2 - Biodentine + PBS intracanal dressing; G3 - MTA e G4 - MTA + PBS intracanal dressing. All access openings were filled with Cimpat Rosa and all root segments were introduced in floral foams moistened with PBS. After 2 months, all root segments were prepared to evaluate the glucose leakage under pressure (103 KPa) for 60 min. The amount of glucose leakage was quantified by a spectrophotometer and the data were analyzed using chi-square test (p < 0.05). To evaluate the BS, 80 dentine sections with 2-mm-thick were obtained from section transversal of human teeth roots. The space of the canal was enlarged using Gates-Glidden burs numbers 2?5 to obtain 1.3-mm-diameter standardized cavities. The sections were immersed in 17% EDTA followed by NaOCl 1%, and were dried. After, the space of the canal were filled with Biodentine and the discs were divided into two groups according to the storage: G1 (n = 40): storage with moistened cotton; G2 (n = 40): PBS. After 30 min, 1, 3 and 28 days, 10 samples of each group were submitted to the push-out test. Data were analyzed using the ANOVA and Tukey test (P < 0.05). With respect to the leakage test, traces of the glucose were observed in a higher number of samples that received Biodentine apical plug (p < 0.05). The exposure of both sealers to PBS intracanal dressing did not influence the sealing ability. With respect to the push-out test, the samples exposed to PBS had lower BS (P < 0.05), except at 1 day (p = 0.6017). The G1, the BS increased each time until 3 days (p < 0.05). The G2 samples, the BS increased within 30 min to 1 day (p < 0.0001), and maintained stable until 3 days (p = 0.9876). At 28 days, were observed a significant decrease of the BS in both groups (p < 0.05). It was concluded that the Biodentine had lower sealing ability than MTA, and generally, the BS increased progressively until 3 days and decreased at 28 days. The exposure of both sealers to PBS did not influence the sealing ability and promoted lower values of BS to Biodentine to dentine.<br>
10

Análise clínico-epidemiológica das fissuras lábio-palatinas no Estado da Bahia

Maranhão, Samário Cintra 03 June 2014 (has links)
Submitted by Edileide Reis (leyde-landy@hotmail.com) on 2015-04-15T03:29:44Z No. of bitstreams: 1 SAMÁRIO CINTRA MARANHÃO.pdf: 2164880 bytes, checksum: 593fe0faf473e0b08b63b1b7d514b602 (MD5) / Made available in DSpace on 2015-04-15T03:29:44Z (GMT). No. of bitstreams: 1 SAMÁRIO CINTRA MARANHÃO.pdf: 2164880 bytes, checksum: 593fe0faf473e0b08b63b1b7d514b602 (MD5) Previous issue date: 2014-06-03 / O objetivo deste trabalho foi realizar uma revisão sistemática dos aspectos etiológicos relacionados ao desenvolvimento das fissuras labio-palatinas. A etiologia desta anomalia é considerada multifatorial, com fortes evidências da interferência de fatores genéticos e ambientais. O completo entendimento deste conjunto de fatores é fundamental para o desenvolvimento de novos estudos que objetivem relacionar o desenvolvimento das fissuras com as suas condicionantes. Foi feito um levantamento nas bases Bireme e Lilacs com as palavras-chave fenda labial, etiologia das fissuras e anormalidades congênitas nos anos de 2012 e 2013. Foram selecionados 59 artigos, que foram revisados e referenciados nos seus apsctos mais relevantes. A posse deste conhecimento permitirá, a posteriori, o entedimento de dados coletados e o desenvolvimento de estratégias de intervenção com finalidade preventiva.

Page generated in 0.0437 seconds