• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 440
  • 83
  • 80
  • 42
  • 41
  • 31
  • 25
  • 25
  • 21
  • 14
  • 12
  • 6
  • 5
  • 4
  • 4
  • Tagged with
  • 998
  • 175
  • 142
  • 96
  • 95
  • 90
  • 90
  • 88
  • 77
  • 72
  • 71
  • 69
  • 69
  • 69
  • 66
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
281

Attract and retain Generation Z in the white-collar business sector. : How to attract and retain Generation Z in the white-collar business sector?

Descos, Lucie, Gospic, Anna-Maria January 2019 (has links)
Problem  Following the expanded competition when it comes to attraction and retention of skilled workers, hence white-collar workers, organizations need to better adapt to the rapid changes in the labor market. Due to the lack of knowledge about the recent Generation Z and their perceptions and values regarding work, the Person-Organization (P-O) fit has been applied in order to gain a deeper knowledge of what attracts and retains individuals of Generation Z, in order for companies to better meet their needs.   Purpose Due to the lack of research done on Generation Z, the purpose of this study is to gain a greater understanding of the values and perceptions of Generation Z and how they operate in the white-collar business sector. Moreover, this creates a greater insight for organizations in order to help them better target the right talent pool and gain a greater understanding of Generation Z that has come to change the labor market.   Method In order to gain a greater knowledge and insight about Generation Z, a qualitative study has been performed to better understand the perception of this Generation. In-depth interviews have been conducted with Generation Z that have or are currently operating in the white-collar business sector in order to meet the purpose of this study. Semi-structured interviews were conducted in order to allow for a fruitful discussion of their values and perceptions and the likely impacts they consider when joining an organization.   Conclusion Generation Z indicated that certain aspects are to consider in the decision-making process of applying or taking a job. Indeed, their own values, beliefs and work-personal life matter to a great extent and is to be matched with the company. This study comes to the result of six determined factors influencing this decision-making process: small enterprises, flexibility trust and freedom, work/private life environmental factors, organizations values/ethics, do what they love, digital natives.
282

Estudo do recozimento simulado e do polígono de obstrução aplicados ao problema de empacotamento rotacional de polígonos irregulares não-convexos em recipientes fechados. / Study of simulated annealing and no-fit polygon applied to the rotational packing problem of irregular non-convex polygons in closed containers.

Martins, Thiago de Castro 03 April 2007 (has links)
Este trabalho trata da proposta de um processo de otimização para o problema do posicionamento rotacional e translacional de formas irregulares em recipientes de dimensões fixas baseado em heurísticas probabilísticas sem o uso de penalização externa. Para tanto, é empregado o polígono de obstrução, acoplado a uma heurística baseada no Recozimento Simulado. O comportamento discreto da função custo em problemas com recipientes de dimensões limitadas foi mitigado através de uma heurística de \"desempate\", que busca diferenciar soluções com valores idênticos através de uma estimativa de quão próxima está uma determinada solução de conseguir encaixar uma forma não-encaixada em seu leiaute. A comparação de resultados deste trabalho com resultados publicados na literatura comprova a validade da abordagem aqui adotada. / This work deals with the proposal of an optimization process for the packing problem with free translations and rotations of irregular shapes on containers with limited dimensions based on probabilistic heuristics without use of extern penalty techniques. For such, the no-fit polygon is used, coupled with an heuristic based on Simulated Annealing. The discrete behavior of the objective function in problems with limited containers is mitigated by a \"tie breaker\" heuristic that sorts solutions with identical values by estimating how close a given solution is of fitting an unplaced shape on its layout. The comparison of these work\'s results with results published on the literature validates the approach here adopted.
283

Modelos de regressão quantílica / Quantile Regression Models

Santos, Bruno Ramos dos 02 March 2012 (has links)
Este trabalho trata de modelos de regressão quantílica. Foi feita uma introdução a essa classe de modelos para motivar a discussão. Em seguida, conceitos inferenciais, como estimação, intervalos de confiança, testes de hipóteses para os parâmetros são discutidos, acompanhados de alguns estudos de simulação. Para analisar a qualidade do ajuste, são apresentados o coeficiente de determinação e um teste de falta de ajuste para modelos de regressão quantílica. Também é proposta a utilização de gráficos para análise da qualidade do ajuste considerando a distribuição Laplace Assimétrica. Uma aplicação utilizando um banco de dados com informação sobre renda no Brasil foi utilizado para exemplificar os tópicos discutidos durante o texto. / This work is about quantile regression models. An introduction was made to this class of models to motivate the discussion. Then, inferential concepts, like estimation, confidence intervals, tests of hypothesis for the parameters are discussed, followed by some simulation studies. To analyse goodness of fit, a coefficient of determination and a lack-of-fit test for quantile regression models are presented. Its also proposed the use of graphs for the goodness of fit analysis considering the Asymmetric Laplace Distribution. An application using a data base with information about income in Brazil was used to exemplify the topics discussed during the text.
284

Estudos de XRD e SAXS aplicados à Polianilina e à Poli(o-metoxianilina) / XRD and SAXS studies applied to Polyaniline and Poly(o-methoxyaniline)

Sanches, Edgar Aparecido 14 March 2011 (has links)
A Polianilina (PANI) e os polímeros derivados da anilina têm recebido grande atenção devido às suas aplicações tecnológicas. A introdução de grupos funcionais polares e de grupos alquila à cadeia principal da PANI é um artifício para se obter polímeros solúveis em uma maior variedade de solventes orgânicos. A Poli(o-metoxianilina) (POMA) é um dos derivados da PANI e sua diferença estrutural está na presença do grupo (-OCH3) na posição orto dos anéis de carbono, sendo bastante estudada na forma de pó ou de filmes para as mais diversas aplicações. Apesar do grande número de trabalhos realizados com a PANI e seus derivados, são poucos os que focam um estudo estrutural desses materiais nas formas dopada (ES) e desdopada (EB). PANI e POMA foram sintetizadas quimicamente utilizando-se 0,5 e 1,0M \'H\'CL\' e tempos de síntese compreendidos entre 0,5 e 96 h. As amostras foram caracterizadas por XRD, SAXS e SEM. Através dos dados de XRD, utilizou-se o ajuste LeBail para obter informações microestruturais através do programa FULLPROF. A análise de XRD mostrou que o tempo de síntese não interferiu significativamente na cristalinidade da PANI, porém, é um parâmetro importante na síntese da POMA, a qual se tornou mais cristalina. Através do SAXS foi possível obter os valores dos raios de giro (Rg) e a dimensão máxima das partículas (Dmáx) a partir da função de distribuição de distâncias entre pares (p(r)) e, através das curvas de Kratky, foi possível analisar qualitativamente a organização das partículas. Através do ajuste LeBail foi possível verificar que o tamanho médio dos cristalitos da PANI-ES e PANI-EB são, respectivamente, 34 e 27 Å. Para a POMA-ES, os cristalitos aumentam com o aumento do tempo de síntese, ficando num intervalo de 26 - 57 Å, enquanto a POMA-EB apresentou cristalitos com 19 Å. As imagens de SEM permitiram a visualização de diferentes morfologias para PANI e POMA: enquanto a PANI-ES apresentou morfologia de fibras formadas por nanoesferas interligadas, a POMA-ES apresentou morfologia globular vesicular, a qual sofreu mudanças significativas com o aumento do tempo de síntese. As morfologias da PANI-EB e POMA-EB mostraram-se bastante diferentes daquelas observadas em suas respectivas formas dopadas. As medidas de condutividade não foram alteradas drasticamente para a PANI, enquanto que para a POMA, a condutividade aumentou durante a síntese. Analisar coerentemente os resultados obtidos através de cada uma das técnicas utilizadas e compreender um pouco mais a estrutura dos materiais poliméricos é essencial para relatar suas propriedades e contribuir com informações para esta misteriosa classe de materiais. / Polyaniline (PANI) and derivatives of aniline have received great attention due to their technological applications. The introduction of polar functional groups and alkyl groups to the main chain of PANI is a practice to obtain soluble polymers in a wider variety of organic solvents. Poly (o-methoxyaniline) (POMA) is a derivative of PANI and its structural difference is the presence of the group (-OCH3) in the ortho position of the carbon rings, been extensively studied in the form of powder or films for the most various applications. Despite the large number of studies performed with PANI and its derivatives, there are few that focus on a structural study of these materials in doped (ES) and undoped (EB) forms. PANI and POMA were chemically synthesized using 0.5 and 1.0 M \'H\'CL\' and synthesis times between 0.5 and 96 h. The samples were characterized by XRD, SAXS and SEM. XRD analysis showed that the synthesis time was not significant in the crystallinity of PANI, however, is an important parameter in the synthesis of POMA, which became more crystalline. Through the data of XRD, we applied the LeBail Fit using the program FullProf, showing that the average size of crystallites of PANI-ES and PANI-EB are respectively 34 and 27 Å. As for the POMA-ES, the crystallites increases with increasing synthesis time, staying in a range from 26 to 57 Å, while the POMA-EB showed crystallites with 19 Å. By SAXS was possible to obtain values of Radius of Giration (Rg) and the maximum particle size (Dmax) from the Pair-distance distribution Function (p(r)) and, through the Kratky curves, was possible to qualitatively analyze the particles organization. The images of SEM allowed the visualization of different morphologies for PANI and POMA: while the PANI-ES showed fibers morphology formed by interconnected nanospheres, the POMA-ES had a globular vesicular morphology, which changed with increasing synthesis time. Morphologies of PANI-EB and POMA-EB were quite different from those observed in their doped forms. The conductivity measurements were not changed drastically for the PANI, whereas for the POMA, the conductivity increased during the synthesis. Consistently analyze the results obtained by each of the techniques and understand the structure of polymeric materials is essential to relate their properties and contribute to this mysterious class of materials.
285

Outcomes of mandibular Kennedy class I and II prosthetic rehabilitation

Chamoko, Joanna Yeukai January 2018 (has links)
Magister Scientiae Dentium - MSc(Dent) (Restorative Dentistry) / Loss of teeth has a negative impact on appearance, nutrition, function and diet. Rehabilitation of tooth loss is an important function of oral health care. Rehabilitation with removable prosthesis of mandibular terminal edentulous areas has been associated with more negative outcomes than of tooth-bounded regions.
286

An intergrated model of the role of authentic leadership, psychological capital, psychological climate and intention to quit on employee work engagement: A comparative analysis

Balogun, Tolulope Victoria January 2017 (has links)
Philosophiae Doctor - PhD (Industrial Psychology) / Organizations exist for the primary aim of meeting particular objectives: innovation and advancement, customer satisfaction, profit making and delivery of quality goods and services. These goals are mostly channelled with the intent of demonstrating high performance crucial for the continued existence of the organization especially in these rapidly changing global economies. This target, however, cannot be achieved without the aid of employees in the organization. A plethora of previous studies have proven that efficiency, productivity, high performance and stability on the job can be better achieved when the employees are dedicated, committed to their work roles and experience work engagement. The experience of work engagement on the part of the employees is not a random event; it depends on a myriad of factors that include authentic leadership. Leaders have a cumulative change effect on their followers; hence, leaders in an organization can be termed as core drivers of employee engagement. Hence, it becomes imperative to seek to understand what authentic leadership as a construct has to offer to the workplace.
287

Análise do desajuste vertical e do afrouxamento de parafusos de próteses sobre implante confeccionadas pelas técnicas do cilindro cimentado ou soldado a laser / Analysis of vertical misfit and screw loosening of implant-supported prosthesis obtained by cemented cylinder or laser welding technique

Oliveira, Danilo Flamini 16 December 2013 (has links)
Este estudo avaliou próteses implantossuportadas obtidas por 2 técnicas (cilindro cimentado ou soldado a laser) e seus comportamentos no que tange à passividade e afrouxamento de parafusos. Foram confeccionadas PPFs de 3 elementos sobre 2 implantes: G1, técnica do cilindro cimentado; G2, técnica do cilindro soldado a laser (n=10). Avaliados níveis de desajuste vertical e passividade antes e após aplicação de cerâmica prensada e após ciclagem mecânica, e a perda de torque inicial dos parafusos de retenção protética antes e após fadiga. Ciclagem mecânica simulando 1 ano de função mastigatória normal (50N, 300.000 ciclos). Análises de desajuste vertical e passividade realizadas pelo método de Sheffield. Calculada % de perda de torque de inserção. Os dados de desajuste e perda de torque foram comparados estatisticamente pelo Modelo Linear de Efeitos Mistos. De modo geral, G1 apresentou níveis de desajuste vertical estatisticamente inferiores a G2 (p<0,05) nas três condições analisadas pelo teste de Sheffield, tanto antes quanto após ciclagem mecânica, atingindo valores máximos de desajuste correspondentes a: 11,94 ± 3,17&mu;m (G1) e 48,63 ± 39,68 &mu;m (G2), antes da ciclagem, 12,42 ± 6,19&mu;m (G1) e 47,62 ± 35,16&mu;m (G2), após a ciclagem, estando os parafusos parafusados. Adicionalmente, em todas as condições experimentais, a ciclagem mecânica não influenciou no desajuste de ambos os grupos (p<0,05), com exceção do molar em G1 quando analisado apertado (p<0,0001). Quando analisado G2, verificamos aumento estatisticamente significante do desajuste vertical após prensagem cerâmica para todos os elementos (p<0,0001) nos diferentes momentos avaliados, com exceção do molar quando avaliado solto, o qual apresentou desajustes semelhantes antes e após prensagem (p=0,052). Na análise de perda de torque, valores expressos em % de perda são apresentados: Pré-molar - G1- antes ciclagem: 31,04 ± 13,22%; G2- antes ciclagem: 33,97 ± 13,41% (G1 x G2 antes ciclagem: p=0,662); G1- após ciclagem: 42,36 ± 14,99%; G2- após ciclagem: 37,92 ± 9,32% (G1 x G2 após ciclagem: p=0,461). Quando analisado o pré-molar, não foram verificadas diferenças estatísticas antes e após ciclagem mecânica para ambos os grupos (G1: p=0,067; G2: p=0,423); Molar - G1- antes ciclagem: 30,77 ± 12,37%; G2- antes ciclagem: 44,37 ± 11,14% (G1 x G2 antes ciclagem: p=0,032); G1- após ciclagem: 39,28 ± 13,96%; G2- após ciclagem: 54,40 ± 26,39% (G1 x G2 após ciclagem: p=0,189). Quando analisado o molar, diferenças estatísticas também não foram identificadas antes e após ciclagem, para ambos os grupos (G1: p=0,392; G2: p=0,233). Diante dos resultados, é possível concluir que: G1 apresentou índices de desajuste vertical e passividade menores que G2, porém para ambos os grupos os desajustes estão dentro dos padrões aceitáveis pela literatura; ciclagem mecânica não promoveu alterações nos níveis de desajuste vertical e perda de torque (%) para ambos os grupos; ambas as técnicas não foram capazes de promover passividade absoluta, tendo em vista os maiores valores de desadaptação do lado solto quando comparados ao lado parafusado. / This study evaluated implant supported prostheses obtained by two techniques (cemented cylinder or laser welded cylinder) and their behavior regarding passivity and screw loosening. Three-element FPPs were made over 2 implants: G1, cemented cylinder technique, G2, laser welded cylinder technique (n=10). The levels of vertical misfit and passivity were evaluated before and after ceramic pressing, and after mechanical cycling; while loss of initial torque of prosthetic retaining screws, before and after mechanical cycling. The mechanical cycling simulated one year of normal masticatory function (50N, 300,000 cycles). Vertical misfit and passivity were analyzed by Sheffield\'s test. The percentage of torque loss was calculated. The misfit and torque loss data were statistically compared by Mixed Linear Model . Overall, G1 showed vertical misfit statistically lower than G2 (p<0.05) in the three conditions analyzed by Sheffield\'s test, before and after mechanical cycling, reaching maximum values of misfit corresponding to: 11.94 ± 3.17&mu;m (G1) and 48.63 ± 39.68 &mu;m (G2) before cycling; 12.42 ± 6.19&mu;m (G1) and 47.62 ± 35.16&mu;m (G2), after cycling, when screws were tightened. Additionally, in all experimental conditions, the mechanical cycling did not influence the misfit in both groups (p<0.05), except for the molar G1 when analyzed in the tightened condition (p<0.0001). When was analyzed G2, statistically significant increase in the vertical misfit was found after ceramic pressing for all elements (p<0.0001) for different moments, except when the molar was not tightened, which showed similar misfit before and after pressing (p=0.052). In the analysis of torque loss, values expressed as percentage of loss are presented: Pre-molar - G1- before cycling: 31.04 ± 13.22%, G2- before cycling: 33.97 ± 13.41% (G1 x G2 before cycling: p=0.662), G1- after cycling: 42.36 ± 14.99%, G2- after cycling: 37.92 ± 9.32% (G1 x G2 after cycling: p=0.461). When the pre-molar was analyzed, statistical differences before and after cycling were not found for both groups (G1: p=0.067; G2: p=0.423); Molar - G1- before cycling: 30.77 ± 12.37%; G2- before cycling: 44.37 ± 11.14% (G1 x G2 before cycling: p=0.032); G1- after cycling: 39.28 ± 13.96%; G2- after cycling: 54.40 ± 26 , 39% (G1 x G2 after cycling: p=0.189). When the molar was analyzed, statistical differences were not found before and after cycling for both groups (G1: p=0.392; G2: p=0.233). Based on these results, it is possible to conclude that: G1 showed vertical misfit and passivity smaller than G2, but for both groups, the misfits are within acceptable standards for the literature; mechanical cycling did not change the vertical misfit and torque loss (%) for both groups; both techniques were not able to promote absolute passivity, in view of the higher values of misfit when compared to the side no tightened.
288

Avaliação da adaptação marginal e rugosidade de superfície de copings confeccionados de Níquel-Cromo e Cobalto-Cromo injetados em moldes de revestimento a temperatura reduzida / Evaluation of the marginal fit and surface roughness of Nickel Cromium and Cobalt Cromium copings injected in refractory molds under reduced temperature

Dias, Ana Paula 30 June 2017 (has links)
A adaptação marginal e a rugosidade de superfície são parâmetros fundamentais para o sucesso clinico e longevidade das coroas metalocerâmicas. O primeiro permite o selamento das bordas do preparo, prevenindo contra problemas relacionados a exposição do preparo aos fluidos orais e a placa bacteriana e o segundo, remete ao auxilio de uma boa adaptação a fatores mecânicos e biológicos importantes a qualidade da restauração final. Visto que ambos os aspectos são diretamente relacionados a temperatura em que as ligas são submetidas, o objetivo deste trabalho foi avaliar o desajuste marginal, por meio de microscopia óptica, e rugosidade de superfície, por meio de microscopia confocal, de copings metálicos obtidos com as ligas metalicas de Ni-Cr [Verabond II e experimental (SR)] e Co-Cr (Keragen) injetadas no molde de revestimento a duas diferentes temperaturas de estufagem (900°C e 700°C), de forma a avaliar se a redução da temperatura de estufagem possa causar o melhoramento do resultado das fundições, minimizando os efeitos das altas temperaturas. As leituras foram realizadas em copings confeccionados a partir da fundição de casquetes de munhão calcináveis. Cada coping foi cimentado a uma matriz (munhão) por meio de um padronizador da pressão de assentamento e levado aos respectivos microscópios para leitura de desajuste marginal e rugosidade de superfície. Para a avaliação do desajuste marginal foi calculada a media das distancias da borda da restauração a borda do preparo a partir de um ponto inicial aleatório selecionado sobre a margem cervical do coping. Duas leituras eram realizadas a cada &frac14; de volta, totalizando 8 leituras por coping. Para os dados obtidos, que tiveram distribuição não normal, foi utilizado o teste não paramétrico de Kruskal Wallis e foi observado que a liga VB apresentou menor desajuste marginal (56,92&micro;m) quando comparado a liga Keragen (66,75 &micro;m) com p<0,05 e a liga SR apresentou resultado intermediário (49,87&micro;m), sem diferença estatística entre as demais. Para comparação das temperaturas foi utilizado o teste Mann-Whitney e a fundição a 700 °C resultou em melhor adaptação marginal que a 900 °C (50,75 &micro;m e 66,75 &micro;m, respectivamente) com p=0,045. Para a avaliação da rugosidade foi selecionada uma área do coping distante 100 m da borda cervical da peca e realizada a leitura. Os dados de rugosidade de superfície seguiram distribuição normal, sendo utilizado um teste paramétrico (ANOVA), seguindo pelo teste de Bonferroni. Ao se compararem as Ligas, SR apresentou menor rugosidade que Keragen (p=0,002) e que Vera Bond (p=0,001); ao se compararem as temperaturas a fundição a 700 °C resultou em menor rugosidade que a 900 °C (p=0,045). O que se concluiu com a presente metodologia apresentada foi que o comportamento das ligas as diferentes temperaturas varia de acordo com a sua composição tanto em relação a superfície quanto a adaptação marginal e que a fundição a 700 °C proporcionou obtenção dos melhores resultados em ambas as variáveis, sendo possível a otimização da superfície da peca fundida sem o comprometimento da adaptação marginal por meio da redução da temperatura de injeção da liga no molde, favorecendo o resultado final das restaurações. / A proper marginal fit and surface roughness are fundamental aspects for the clinical success of metal-ceramic crowns. The first parameter allows to preserve the margins adaptation accuracy of the restaurations, thus preventing issues related to an improper exposition of the dental tissues into the oral fluids and biofilm. The second parameter is related to mechanical and biological important aspects for the restoration quality and is also able to optimize the piece final adaptation. Both parameters are associated to temperature levels and the understanding of their behavior is convenient for the improvement of the Fixed Prostheses, therefore the aim of this study was to mensure the maginal gap by using the optical microscopy and evaluate the surface roughness by confocal microscopy of metallic copings fused with Nickel-Chromium alloys [Verabond II e experimental (SR)] and Cobalt- Chromium (Keragen) under two distinct mold temperature for the alloy injection: 700°C and 900°C. Performing those analysis represents a way to find out if the temperature reduction of the mold can be convenient to increase the quality of the casting patterns`s surface without affect the marginal fidelity, thus minimizing the overheat casting problems. The mensurements were performed in copings fused from resin cylinders for casting and each one, after fused, was cimented in a abutment cylinder analogue with standardized pression and placed under the respective microscopes for marginal fit and surface analyses. For the marginal fit mensurement were selected two equidistant points in a metal coping that representing &frac14; turn on the measurement device, in a total of 8 measurements for coping in each step that results in a misfit average. Once it was found a non-normal distribution, the non-parametric Kruskal Wallis test was performed for the data and was observed that the allow VBII conferred lower values of marginal fit (56,92 &micro;m) when compared to Keragen alloy (66,75 &micro;m), p<0,05, and SR conferred average values between the others (49,87 &micro;m),with no statistic difference. In the comparison between the mold temperatures the Mann-Whitney test was implemented and the temperature at 700°C reveled better results of marginal fit than the 900 °C temperature (50,75 &micro;m e 66,75 &micro;m, respectively) with p=0,045.For the surface analysis was selected an anatomic reference line in each coping and was set up a distance of 100 &micro;m from this point to make the quantification. For the surface roughness data, with normal distribution, comparisons were performed using a parametric test for independent data (ANOVA), followed by Bonferroni test. The level of significance was set at 5%. At the comparison of alloys, the SR granted lower values of roughness in its patterns than Keragen (p=0.002) and Verabond II (p=0,001). Comparing the temperatures, the values of roughness of the patterns fused under 700° were lower than those fused under 900° (p=0,045). There was no significant difference for interaction between alloy X temperature (p=0,280). The conclusion of the present study was that the behavior of the alloys regarding the marginal fit and surface roughness vary depending of its composition and the Mold temperature and Pieces injected at 700°C in the mold conferred better results in both parameters, therefore being possible to optimize the fixed photesis casting patterns surfaces without marginal fit commitment by reducing the mold temperature for the alloy injection, thus Contributing to the quality of the metal ceramic restorations.
289

EXAMINING THE RELATION BETWEEN CONTEXTUAL FIT AND IMPLEMENTATION FIDELITY ON BEHAVIOR SUPPORT PLANS AND STUDENT OUTCOMES

Monzalve, Manuel 21 November 2016 (has links)
An extensive body of empirical evidence indicates that function-based behavior support plans are likely to be more effective and efficient in school settings than plans that are not function-based. Designing technically adequate behavior support plans, however, is not sufficient to ensure that these plans will be implemented with fidelity by school staff. The contextual “fit” of support plan procedures with the values, skills, resources and administrative support of implementing personnel also affects the likelihood of implementation. In this dissertation a single-subject concurrent multiple baseline design across participants was used to examine the efficacy of the Contextual Fit Enhancement Protocol (CF Intervention). The CF Intervention was designed to improve the contextual fit of support plans for four elementary school students with problem behaviors. This CF Intervention was designed based on the assumption that when procedures included in a plan match the values, skills, administrative support and resources of the people responsible for implementation the plans will be implemented with higher fidelity and will be more likely to produce desired student outcomes. Results from the study indicate that after implementation of the CF Intervention, support plans that were already technically adequate improved in contextual fit: instructional staff (a) had a better understanding of behavioral procedures being used, (b) received specific, systematic feedback about its implementation, (c) perceived high levels of administrative support, and (d) perceived a collective commitment to improve current plans. Following implementation of the CF Intervention, substantial increases in implementation fidelity and decreases in student problem behavior were observed. In addition, teacher participants rated the CF Intervention process as effective and efficient. Limitations and implications for future research, practice, and training are discussed.
290

Avaliação da deformação do intermediário e região perimplantar de próteses implanto-suportada unitárias parafusada: estudo através da extensometria / Evaluation of abutment and perimplantar region deformation of implant-supported screwed prostheses: an study using strain gauges

Moretti Neto, Rafael Tobias 05 August 2010 (has links)
O implante dental depende do osso de suporte para sua estabilidade e ongevidade funcional. O comportamento mecânico e a estrutura trabecular do osso afetam a interface com o implante. Tal conhecimento pode fornecer uma base para melhoramentos na função e desenho dos implantes atuais minimizando a reabsorção da crista óssea e falha na junção osso-implante. Desta forma a correta quantificação das forças que atuam sobre o sistema de implante e principalmente no osso de suporte ao qual ele está inserido é importante para o entendimento da biomecânica possibilitando que intervenções possam ser realizadas pelos profissionais visando assim à longevidade das próteses implanto-suportadas bem como dos implantes que as sustentam. Por essa razão, a proposta deste trabalho foi avaliar, com auxílio de extensômetros elétricos, se o processo laboratorial de confecção de coroas metalocerâmicas resulta em alterações das tensões no osso ao redor dos implantes. Para isto foi utilizado um modelo de poliuretano em forma de U simulando o osso mandibular com dois implantes de hexágono externo de 3,75mm de diâmetro por 13 mm de comprimento, nos quais foram fixados intermediários multi-unit. Os corpos de prova foram confeccionados com dois tipos de ligas odontológicas - Cobalto-Cromo e Paládio-Prata - e três tipos de cilindros protéticos calcinável, usinado de Cobalto-Cromo e usinado de Ouro. As leituras de deformação foram realizadas em dois momentos: 1- após a fundição das infra-estruturas e 2 após estas infra-estruturas terem recebido cobertura cerâmica. Os testes foram realizados parafusando os corpos de prova sobre os intermediários utilizando-se para isto um dispositivo eletrônico de torque com força máxima de 10 Ncm. Os resultados mostraram que, após a aplicação da cobertura cerâmica, ocorreu piora da condição de assentamento aos intermediários. O mesmo não foi detectado quando se avaliou a deformação do osso simulado, já que os valores de deformação não ndicaram diferenças antes e após a aplicação da cerâmica. / The dental implant depends on the supporting bone for its stability and functional longevity. Mechanical behavior and trabecular bone structure affect the interface with the implant. Such knowledge may provide a basis for improvements in the current implant function and design, decreasing bone crest resorption and failure at bone-implant junction. Adequate quantification of forces that act upon the implant system and mainly on the supporting bone is important for understanding the biomechanics, allowing the intervention by professionals with the purpose of achieving the longevity of implant-supported prostheses. Therefore, this work aims at evaluating, with the aid of strain gauges, whether the laboratorial process of metal ceramic crown fabrication results in changes of the tensions around the implants. A U-shaped polyurethane model simulating the mandibular bone with two 3.75-mm diameter and 13-mm length external hexagon implants were used with fixed multi-unit abutments. Specimens were prepared with two types of dental alloys - cobalt-chromium and silver-palladium - and three types of prosthetic cylinder castable plastic, prefabricated in cobalt-chromium or gold. The deformation readings were performed in two moments: 1- after framework casting and 2- after ceramic layering of the framework. The tests were performed with the framework screwed onto the abutments at 10Ncm using an electronic torque device. The results showed that the ceramic layering worsened the fit between the crowns and the abutments. The same was not detected when bone deformation was evaluated since the values were not statistically different.

Page generated in 0.0847 seconds