• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 119
  • 1
  • 1
  • Tagged with
  • 121
  • 120
  • 117
  • 115
  • 107
  • 99
  • 75
  • 73
  • 69
  • 62
  • 60
  • 56
  • 42
  • 28
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Efeito do tipo de revestimento estetico e da eletroerosão sobre a desadaptação de infra-estruturas implanto-suportadas fundidas em titanio c.p. / The influence of the veneering application and Spark erosion on the misfit level of implant-supported frameworks

Nakaoka, Marcia Mika 22 June 2007 (has links)
Orientador: Marcelo Ferraz Mesquita / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T19:46:50Z (GMT). No. of bitstreams: 1 Nakaoka_MarciaMika_D.pdf: 1091285 bytes, checksum: 76d1bd5bef1fb0bee757a9f929be3f3a (MD5) Previous issue date: 2007 / Resumo: As distorções oriundas das técnicas de aplicação de revestimentos estéticos sobre infra-estruturas metálicas de próteses fixas podem resultar em margens cervicais desadaptadas. Dessa forma, este trabalho propôs-se a avaliar o efeito do tipo de revestimento estético, da simulação dos ciclos de cocção da cerâmica, e da aplicação da eletroerosão, sobre o desajuste de infra-estruturas implanto-suportadas fundidas em titânio comercialmente puro (Ti c.p.). Foi utilizada uma matriz metálica contendo 5 pilares intermediários do tipo Microunit. Sobre ela, foram enceradas 40 infra-estruturas, posteriormente fundidas em Ti c.p. (Tritan, Dentaurum, Alemanha). Para cada infraestrutura foi confeccionado um index, com 5 análogos parafusados em cada infra-estrutura. Esse conjunto foi posicionado em microscópio para a mensuração dos desajustes antes da aplicação dos revestimentos estéticos, com a finalidade de avaliar apenas desajuste provocado pela aplicação dos revestimentos estéticos e pelo ciclo de cocção da cerâmica. As infra-estruturas foram separadas, aleatoriamente: G1: resina acrílica ativada termicamente (Clássico, Clássico Artigos Odontológicos Ltda., São Paulo, Brasil); G2: resina fotopolimerizável (Versyo.com, Heraeus Kulzer, Brasil); G3: cerâmica (Triceram, Dentaurum J. P. Winkelstroeter KG ¿ Pforzheim - Alemanha); G4: simulação dos ciclos de cocção da cerâmica. Novamente, após a aplicação dos revestimentos estéticos, foi realizada a avaliação do desajuste marginal sobre o index. Procedeu-se o processo de eletroerosão (Tel Med Technologies, Port Huron, Michigan, EUA). As leituras de desajuste foram realizadas após o aperto com 10 Ncm em um único parafuso, correspondente ao implante A. Através desse procedimento, verificou-se a adaptação dos componentes C e E. O procedimento foi repetido com o outro implante mais distal (E), para mensuração nos implantes A e C. As leituras foram realizadas utilizando microscópio mensurador, com aumento de 120X e precisão de 0,5µm (Micro Vision ¿ Leika, Wetzlar, Alemanha), antes e após aplicação dos revestimentos estéticos, e após o processo de eletroerosão. Os resultados obtidos foram submetidos à Análise de Variância e ao teste de Tukey (p<0,05). Os valores de desajuste marginal das infra-estruturas antes da aplicação dos revestimentos estéticos não apresentaram diferença estatística significante entre si: G1: 29,81 'mu' (+ 10,66); G2: 35,30 'mu' (+ 12,15); G3: 44,75 'mu'(+ 13,73); G4: 38,57 'mu' (+ 16,94). A aplicação dos revestimentos estéticos e a simulação dos ciclos de cocção da cerâmica aumentaram significantemente os valores médios de desajuste marginal para todos os grupos: G1: 221,70 'mu' (+14,11); G2: 81,91 'mu' (+15,71); G3: 233,99 'mu' (+39,18); e G4: 119,75 'mu' (+38,08). Os grupos G1 e G3 não apresentaram diferença estatisticamente significante entre si, mas apresentaram diferença quando comparados aos G2 e G4. Após o processo de eletroerosão, apenas para o grupo G3: 161,16 µm (+36,59 ) a média de desajuste marginal apresentou-se com valor significamente menor. As médias de desajuste marginal para os grupos G1: 198,68 mu' (+34,19); G2: 62,03 'mu' (+17,73) e G4: 87,98 'mu' (+39,32) foram numericamente menores, porém, sem diferença estatística. Como ocorrido anteriormente, os grupos G1 e G3 não apresentaram diferença estatística significante, mas ambos apresentaram diferença quando comparados aos grupos G2 e G4. A partir dos resultados obtidos no presente estudo, conclui-se que os revestimentos estéticos em resina acrílica ativada termicamente e em cerâmica produziram os maiores valores de desajuste marginal para próteses implanto-retidas, enquanto a resina fotopolimerizável, os menores. A aplicação de cerâmica nas infra-estruturas produziu maiores valores de desajuste marginal quando comparado à simples simulação dos ciclos de cocção. O processo de eletroerosão mostrou-se eficaz na redução dos desajustes marginais apenas para o grupo com aplicação da cerâmica / Abstract: The demand for a passive fit of frameworks for osseointegrated endousseous implants abutments is well known, because the tightening of an inaccurate framework to the abutments can transmit stress to the bone-metal interface. The purpose of the present study was to evaluate the influence of the veneering application and porcelain firing cycle on the misfit level of implant-supported frameworks. Forty Ti c.p. (Tritan, Dentaurum, Germany) alloy frameworks were fabricated from a metallic index containing 5 Branemark type multi unit abutments. Analogs of the abutments were positioned to the framework, to construct an index for each framework. This index allowed the observation of the marginal gaps caused by the application of the veneering material. The frameworks were grouped (n=10): 1) heat acrylic resin (Clássico, Clássico, São Paulo, Brazil); 2) light polymerized resin (Versyo.com, Heraeus Kulzer, Brazil); 3) porcelain application (Triceram, Dentaurum - Germany); 4) simulation of porcelain firing cycle. Marginal refinement with spark erosion was conducted on specific equipment (Tel Med Technologies, U.S.A.). The marginal gap was obtained before and after the veneering materials and the spark erosion procedure, following the single screw test protocol (using a tightening force of 10 Ncm). A traveling microscope (STN ¿ Olympus Optical Co. Ltd Japan (120X) was used, tightening 10N in the titanium screw of the extremity distal implant, measuring the gaps at the central and distal implants. Data were subject Analysis of Variance followed by Tukey test (5%). Marginal gap mean values of the frameworks before the veneering application were not significantly different: G1: 29.81 'mu' (+ 10.66); G2: 35.30 'mu' (+ 12.15); G3: 44.75 'mu' (+13.73); G4: 38.57 'mu' (+ 16.94). The application veneering materials and the simulation of porcelain firing cycle increased significantly the misfit mean values of all groups: G1: 221.70 'mu' (+14.11); G2: 81.91 'mu' (+15.71); G3: 233.99 'mu' (+39.18); e G4: 119.75 'mu' (+38.08). There were no significant differences between G1 and G3, but they were significantly different from both G2 and G3. After the spark erosion process, marginal gap mean value decreased significantly only G3 group: 161.16 µm (+36.59). G1: 198.68 'mu' (+34.19); G2: 62.03 'mu' (+17.73) and G4: 87.98 'mu' (+39.32) groups decreased the marginal gap mean values, but not significantly after the spark erosion procedure. As occurred after the application of veneering materials, G1 and G3 groups did not show significant difference, but they both were significantly different from G2 and G4 groups. It can be concluded that heat cured acrylic resin and porcelain produced the highest mean values of marginal gaps, while light cured acrylic resin, the lowest. The application of porcelain produced higher misfit values than the simulation of porcelain firing cycles. After the spark erosion process, marginal gap mean value decreased significantly only porcelain application grou / Doutorado / Protese Dental / Mestre em Clínica Odontológica
62

Desajuste marginal e influencia na pre-carga de parafusos e nas tensões induzidas as fixações de pilares metaloplasticos sobre-fundidos / Marginal misfit and influence in the pre-load and the stress-induced setting of the metaloplastic abutments

Luthi, Leonardo Flores, 1984- 15 August 2018 (has links)
Orientador: Guilherme Elias Pessanha Henriques / Dissertação (mestrado) - Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-15T12:37:57Z (GMT). No. of bitstreams: 1 Luthi_LeonardoFlores_M.pdf: 40460066 bytes, checksum: 7100a1650e58ebfc4a879fff3da50814 (MD5) Previous issue date: 2010 / Resumo: Pilares tipo UCLA calcináveis são de ampla aplicabilidade na Implantodontia, pois permitem a manipulação em laboratório a custo reduzido e a individualização das próteses em função de cada paciente. Entretanto, apresentam piores resultados de adaptação marginal que os pilares pré-fabricados, embora estes agreguem custos significativamente superiores. Pilares UCLA metaloplásticos para sobre-fundição surgiram neste interstício, com prerrogativas de menores custos que os pré-fabricados e melhor adaptação que os calcináveis. Atualmente encontram-se, predominantemente, com base em liga de Ni-Cr-Ti ou Co-Cr. Todavia, não há dados relativos ao seu desempenho após a sobre-fundição, tão pouco, diante das ofertas, qual seria a melhor escolha. O objetivo neste estudo foi avaliar os desajustes marginais e a influência na indução de tensão e no destorque de parafusos protéticos de próteses confeccionadas com pilares UCLA metaloplásticos confrontando seus resultados com pilares UCLA calcináveis. Foram confeccionadas quarenta infraestruturas metálicas simulando próteses parciais fixas de três elementos retidas por dois implantes osseointegrados, obtidas por fundição a partir de transferências realizadas no modelo mestre. As estruturas foram separadas em quatro grupos (n=10) : G1, cilíndros protéticos tipo UCLA metaloplásticos com base em Co-Cr; G2, cilíndros protéticos tipo do UCLA calcináveis e fundidos em liga de Co-Cr; G3, por cilíndros protéticos tipo UCLA metaloplásticos com base em Ni-Cr-Ti; e G4, por cilíndros protéticos tipo do UCLA calcináveis e fundidos em liga de Ni-Cr-Ti. Para mensuração dos valores de desajuste marginal foi utilizada a técnica do parafuso único, o método de extensometria foi usado para análise das tensões, e os valores de pré-carga dos parafusos, após a ciclagem mecânica, foram obtidos por meio de torquímetro eletrônico digital. Os dados de desajuste marginal e tensão foram verificados antes e após a ciclagem mecânica, já os valores de pré-carga foram obtidos em intervalos de 100 mil ciclos. Os dados foram submetidos à análise variância (Três Fatores), seguidos de teste de Tukey (p=0,05) e a presença de correlação foi verificada por meio do teste de Pearson. Não foi encontrada diferença significativa entre os tipos de pilares para o desajuste, tensão e pré-carga. Os valores médios para desajuste (µm) foram G1 (3608,7 ± 1429,6) G2 (7918,3 ± 5055,9) G3 (4577,3 4017,2) G4 (9824,2 ± 1100,6). Os valores médios para tensão (gf) foram G1 (7918,3 ± 5208,8) G2 (3608,8 ± 2335,9) G3 (9824,3 ± 4125,5) G4 (4577,3 ± 15510,3). Os valores médios de pré-carga (Ncm) dentre os ciclos 0 (11,7 ± 3,8), 100 mil (9,7 ± 3,4), 200 mil (8,9 ± 3,7), 300 mil (9,3 ± 3,2), 400 mil (9,7 ± 3,4), 500 mil (10,6 ± 4). O uso de pilares metáloplasticos não reduziu os valores de desajuste marginal e tensão quando comparados aos calcináveis. A liga de Co-Cr apresentou os menores valores de desajuste marginal. O tipo de pilar e a liga utilizada influenciaram negativamente na perda de pré-carga. Não existe correlação entre tensão, desajuste marginal e pré-carga. / Abstract: Castable UCLA abutments are of wide applicability in dental implants, because they allow the manipulation in the laboratory at low cost and individualization of abutments for each patient. However, they show the worse results of marginal adaptation then the fabricated, although these aggregate costs significantly higher. UCLA premachined abutments for casting came in this interstice, with those of a lower cost than pre-made and better adaptation of the abutment. Nowadays, they are manufactured predominantly based on Ni-Cr-Ti or Co-Cr alloys. However, there is no data on its performance after the overcasting, and little is known about which one would be the best choice. Thus, the aim of this study was to analyze the marginal misfit and its influence on tension induction and in preload values of prosthetic screws in prostheses made with premachined UCLA abutmens. Forty frameworks were prepared simulating three-element metal fixed partial dentures retained by two osseointegrated implants, which were obtained through casting of acrylic resin frameworks waxed in a master model. The structures were distributed into four groups (n = 10): Group 1- premachined Co-Cr UCLA abutment; Group 2- casted Co-Cr UCLA abtument (control group 1); Group 3- premachined Ni-Cr-Ti UCLA abutment and Group 4- casted Ni-Cr-Ti UCLA abutment (control group 2). To measure the values of marginal misfit the single screw technique was used. The method of strain gage was used to analyze the stresses; and the values of preload of the bolts after cycling mechanics, were obtained by means of digital electronic torque meter. The data of marginal misfit and strain were obtained before and after of the mechanical cycling, but the values of pre-load were obtained at intervals of 100 thousand cycles. The data were submitted to variance analysis (Three-Way), followed by Tukey test (p=0.05) and the presence of correlation was verified by means of the Pearson correlation. The average values for marginal misfit (µm) were, G1 (3608.7 ± 1429.6), G2 (7918.3 ± 5055.9), G3( 4577.3 ± 4017.2), G4 (9824,2 ± 1100.6). The average values for tension (gf) were: G1 (7918,3 ± 5208.8), G2 (3608.8 ± 2335.9), G3 (9824.3 ± 4125.5) and G4 (4577.3 ± 15510.3). The averages values of preload (Ncm) among the phases: 0 (11.7 ± 3.8), 100 thousand (9.7 ± 3.4), 200 thousand (8.9 ± 3.7) 300 thousand (9.3 ± 3.2), 400 thousand (9.7 ± 3.4), 500 thousand (10.6 ± 4). The use of premachined UCLA abutment did not reduce the values of marginal misfit and strain when compared with the plastic UCLA abutments. The alloy of Co-Cr showed the lowest values of marginal misfit. The kind of abutmetns and alloy used influenced the values of preload. There was no correlation between strain, marginal misfit and preload. / Mestrado / Protese Dental / Mestre em Clínica Odontológica
63

Avaliação da deformação gerada nos componentes intermediários de prótese fixa implanto-suportada com diferentes alturas, com a utilização de extensômetros lineares elétricos / Assessment of the deformation of the generated in different heights of abutments of mandibular implant-supported prosthesis, with the use of strain Gauges

Valdey Suedam 10 June 2005 (has links)
Em prótese total fixa implanto-suportada as diferentes alturas dos intermediários traduzem-se em diferentes braços de alavanca aos quais os implantes são submetidos levando a um efeito de deformação dos componentes que até o momento é desconhecido. O objetivo deste trabalho foi verificar a deformação gerada em diferentes alturas de componentes intermediários de prótese total fixa mandibular implanto-suportada. Para isto foi utilizado um modelo mestre de forma circular confeccionado em aço comum (Aço 1010/20) com cinco perfurações onde foram adaptadas as réplicas de fixação de 3,75mm de diâmetro, nas quais foram fixados os intermediários. O trabalho apresentou dois grupos de três corpos de prova cada, divididos de acordo com o tipo de liga das infra-estruturas(CoCr ou PdAg) e altura dos intermediários (4,0 mm, 5,5 mm e 7,0 mm), respectivamente. Foi aplicada uma força de 100N, em um ponto de referência pré-determinado na extremidade livre, a uma distância de 15mm do centro da réplica de fixação terminal e realizadas leituras das deformações geradas na mesial e na distal de cada intermediário, com o uso de extensômetros lineares elétricos. Os resultados do estudo demonstraram que o aumento da deformação captada no intermediário adjacente ao cantilever é promovido pelo aumento da altura dos intermediários e também pela utilização de uma liga de alto módulo de elasticidade. / In implant-supported prosthesis the different heights of abutments represent different lever arms to which the implants are submitted, leading to a deformation of the components that is not completely understood. The objective of this study was to assess the deformation ocurring in different heights of abutments of mandibular implant-supported fixed prosthesis. A circular master cast made of steel (Steel 1010/20) was used with five perforations containing implant replicas of 3,75mm of diameter in which the abutments were seated. The specimens were divided in two groups of three specimens each, according to the type of alloy of the framework (CoCr or PdAg) and the abutment's height (4,0 mm, 5,5 mm and 7,0 mm), respectively. A force of 100N was applied at a point 15mm distal to the center of the terminal abutment. Readings of the deformations generated on the mesial and distal aspects of the abutment were obtained with the use of strain gauges. The results of this study demonstrated that the deformation observed in the abutments adjacent to the cantilever arm is proportional to the increase of the abutment's height and elastic modulous of the alloy.
64

Avaliação da deformação gerada na região peri-implantar de prótese fixa implantossuportada, com a utilização de extensômetros lineares elétricos / Evaluation of peri-implant bone deformation of a mandibular cantilevered implant-supported prosthesis, with the use of strain gages

Valdey Suedam 07 August 2009 (has links)
O comportamento mecânico das próteses parciais fixas implanto-suportadas são foco de vários estudos, onde o entendimento do processo de transmissão de forças mastigatórias e suas reações na estrutura óssea peri-implantar ainda não são totalmente compreendidos. Por isso, o objetivo deste trabalho foi verificar a deformação gerada na região peri-implantar de prótese parcial fixa mandibular. Para isto foi utilizado um modelo de poliuretano em forma de U simulando o osso mandibular com dois implantes hexágono externo de 3,75mm de diâmetro por 13mm de comprimento, nos quais foram fixados intermediários multi-unit. O trabalho apresentou dois grupos divididos de acordo com o tipo de liga das infraestruturas (CoCr ou PdAg) os quais foram submetidos a quatro situações de aplicação de carga. Foram aplicadas forças de 300N, nos pontos de referência pré-determinados na barra entre os implantes e na extremidade livre (5mm, 10mm e 15mm de cantilever). Foram realizadas leituras das deformações geradas na distal, lingual, mesial e vestibular de cada implante, com o uso de extensômetros lineares elétricos, as quais foram correlacionadas com a teoria de remodelação óssea proposta por Frost. Os resultados do estudo demonstraram que a deformação é influenciada pelo ponto de aplicação de carga e pelo módulo de elasticidade da liga da barra. A deformação é diretamente proporcional ao comprimento do cantilever, onde comprimentos maiores do que 10mm provocam tensões que superam a tensão máxima fisiológica proposta pela teoria de Frost. / The mechanical behavior of implant-supported prosthesis is focus of some studies, with the process of bite forces transmissions and its peri-implant bone reactions is not completely understood yet. Therefore, the aim of this study was to verify the deformation in peri-implant region of mandibular fixed partial prosthesis. A U shaped polyurethane model was used to simulated the mandibular bone with two external hexagon implants with 3.75mm of diameter an 13mm of length, provided with multi-unit abutments. Two groups were formed according to the type of alloy of the framework (CoCr or PdAg), which were submitted to four load conditions. Loads of 300N were applied, in the predetermined points on the framework between the implants and the cantilever (5mm, 10mm and 15mm distal to the terminal implant). Readings of the deformations generated on the distal, lingual, mesial and bucal aspects of each implant were obtained with the use of strain gages, which were correlated to the theory proposed by Frost on bone remodeling. The results of the study demonstrated that deformation is influenced by the point of load application and by the elastic modulus of the alloy of the framework. The deformation is directly proportional to the cantilever length. Lengths bigger than 10mm generate tensions that exceed the maximum effective strain proposed by Frost.
65

Resistência à fratura de coroas metalocerâmicas implanto-suportadas cimentadas e parafusadas / Fracture resistance of metal-ceramic cement- and screw-retained implant-suport single crowns

José Luiz Góes de Oliveira 30 March 2009 (has links)
Nas próteses sobre implante, a escolha do sistema de retenção (cimentada ou parafusada) muitas vezes está relacionada com a preferência pessoal de cada profissional. Porém alguns aspectos que diferem esses tipos de prótese devem ser levados em consideração no momento desta seleção. A passividade de assentamento, a reversibilidade, a estética, a oclusão e a presença do orifício de acesso ao parafuso. A ausência de orifícios de acesso ao parafuso é uma grande vantagem quando se utilizam próteses cimentadas principalmente quando se trata de casos onde a estética é uma prioridade. Além disto, a descontinuidade da cerâmica nas próteses parafusadas pode se apresentar como um fator de fragilização para a cerâmica. Isto se torna ainda mais grave quando o orifício de acesso ao parafuso constituído apenas por cerâmica com o objetivo de minimizar sua deficiência estética. É neste sentido que o presente trabalho se propõe a avaliar a resistência à fratura da cerâmica em próteses metalo-cerâmicas implantosuportadas cimentadas e parafusadas com dois diferentes desenhos de infraestruturas. Além disto, observar se a simulação de envelhecimento da cerâmica através da ciclagem mecânica influencia na sua resistência à fratura sob carga compressiva. Para isto, 10 coroas metalo-cerâmicas cimento-retidas (Grupo controle), 10 coroas metalo-cerâmicas parafusadas diretamente sobre o implante e orifício de acesso ao parafuso em metal medindo 2mm de altura (Próteses parafusadas com \"chaminé\") e 10 coroas metalo-cerâmicas parafusadas diretamente sobre o implante com orifício de acesso ao parafuso em porcelana medindo 2mm de altura (Próteses parafusadas sem \"chaminé\") foram confeccionadas de forma padronizadas. Metade dos corpos-de-prova de cada grupo (n=5) foram submetidas ao teste de ciclagem mecânica com auxílio de uma máquina eletro-mecânica de fadiga que continha um dispositivo de aço inoxidável com a ponta da forma esférica (6mm de diâmetro) que promovia uma carga simultânea em 4 vertentes triturantes (2 vestibulares e 2 linguais), simulando um contato com o dente antagonista por 1.200.000 ciclos, com uma freqüência de contato de 2Hz e carregamento de 100N, em água a uma temperatura de 37ºC. Todos os corpos-de-prova foram submetidos ao teste de compressão axial realizado em uma máquina de testes a uma velocidade de 0,5mm/min para que um dispositivo de extremidade arredondada(6mm de diâmetro) entrasse em contato com a coroa. Os valores médios da força requerida para a fratura dos corpos-de-prova foram calculados e comparados pela análise de variância a 2 critérios (1= tipo de infra-estrutura; 2= ciclagem prévia) e teste de Tukey. Pode-se concluir que a ciclagem mecânica não influenciou na resistência final dos corpos-de-prova quando submetidos à carga compressiva. Além disto, verificou-se que as próteses cimentadas apresentaram maior resistência à fratura da cerâmica que as duas variações de infra-estrutura para próteses parafusadas com níveis de significância estatística (p\' < OR =\'0,5). Entre as próteses parafusadas não foram observadas diferenças estatisticamente significantes (p\' > OR = \'0,5). / In implant prosthodontics, the choice of retention system (cemented or screwed) is often related to personal preferences of each professional. However, some aspects that differenciate these 2 types of prosthesis must be considered at the time of selection: the passivity of the fit, the reversibility, the aesthetics, the occlusion and the presence of the occlusal opening of the screw-access hole. The absence of access hole is a great advantage when using cemented prosthesis especially when it comes to cases where aesthetic is a priority. In addition, the discontinuing of the ceramic in the screwed prosthesis may be a factor of weakening. This becomes even more serious when the screw-access hole is totally ceramic in order to minimize its aesthetic deficiency. The aim of this study was to evaluate the resistance to fracture of cemented and screw-retained implant-supported metalloceramic crowns with two different frameworks designs. Moreover, the influence of the aging of ceramics by mechanical cycling on the resistance to fracture under compressive load was also observed. Ten cement-retained, ten screw-retained with the screw-access hole in metal measuring 2mm height (\"chimney\") and ten screw-retained with screw-access hole in ceramic measuring 2mm height (without \"chimney\") single crowns were manufactured. All screw-retained crowns were screwed directly over the implant. Half of the specimens from each group (n=5) were subjected to Mechanical cycling. The load (100N, 1.200.000 cycles, 2 Hz) was applied by a spherical stainless steel tip (6mm in diameter) simultaneously on 4 cusps (2 buccal and 2 lingual), simulating the contact with the antagonist tooth, under water at 37oC. All specimens were subjected to axial compression with a spherical tip (6mm in diameter) in a universal testing machine at 0.5mm/min. Mean values of maximum force required to fracture were analyzed using 2-way ANOVA (1=framework, 2=mechanical cycling) and Tukey\'s test for multiple comparisons (p\' < OR =\'0,5). Mechanical cycling did not affect the strength of the specimens when subjected to compressive load. Cemented prosthesis had greater resistance to fracture than the two variations of screwed frameworks with statistically significantdifferences. Between the 2 types of screwed prosthesis no statistically significant differences were observed.
66

Correlação da tensão no intermediário e as medidas de comprimento, altura e angulação de infraestruturas de próteses sobre implantes / Correlation of abutment tension and measures of length, height and angle of implant-supported prostheses framework

Fernanda Furtado Piras 28 May 2015 (has links)
A adaptação passiva e estabilidade têm sido descritos como pré-requisitos importantes na escolha dos materiais e técnicas de confecção em prótese implantossuportada. A proposta deste trabalho foi estudar, com auxílio dos strain gauges, a deformação média gerada nos intermediários após a aplicação de carga axial em infraestruturas confeccionadas por três diferentes materiais. Além disso, através da microscopia confocal a laser, avaliar as medidas de comprimento, altura e angulação desses espécimes e mini pilares. Esses dados foram submetidos à análise estatística, a fim de encontrar possível correlação entre a deformação gerada e as medidas internas das infraestruturas com as externas dos intermediários em que foram parafusadas. Para essa investigação foi utilizado um modelo em poliuretano com dois implantes, hexágono externo, posicionados nas áreas dos dentes 43 e 45. A partir deste modelo, 12 infraestruturas de três elementos foram fabricadas e divididas em 3 grupos (n=4) de acordo com a técnica utilizada: (C) fundição convencional em Ni-Cr; (U) usinada em zircônia por CAD/CAM e (S) sinterizada a laser em Co-Cr pelo CAD/CAM. Durante a aplicação de carga axial, as tensões geradas foram registradas por extensômetros unidos aos intermediários, e avaliadas quantitativamente e qualitativamente. De maneira geral, houve um predomínio de áreas de compressão, sendo que as poucas áreas de tração apresentaram baixos valores. O grupo sinterizado a laser foi o único que apresentou forças compressivas para todos os sensores. Os grupos usinado e convencional apresentaram comportamento semelhante, diferindo apenas em uma região. Posteriormente, as infraestruturas e os intermediários foram submetidos à microscopia confocal para avaliação de ângulo, comprimento e altura de suas paredes internas (infraestruturas) e externas (intermediários), nas regiões correspondentes à localização dos strain gauges. Para a angulação, todos os grupos mostraram valores semelhantes entre si e maiores que os dos mini pilares. Quanto ao comprimento e altura, todos valores foram diferentes entre si. Em relação aos mini pilares, os valores foram maiores na altura e menores no comprimento. Estes resultados foram analisados pelo método estatístico de Pearson o que levou à conclusão que, para algumas regiões dos medidores de tensão, há correlação entre deformação e comprimento, e também, deformação e ângulo. Quanto maior o ângulo, e quanto menor for o comprimento, maior a deformação mostrada. / The passive adaptation and stability have been described as important prerequisites in the choice of materials and manufacturing techniques in implant-supported prosthesis. The aim of this work was to study, with the aid of strain gauges, the average deformation generated in the abutment, after application of axial load on frameworks made up of three different materials. Besides, through confocal laser microscopy, assess the length, height, and angle of these specimens, and abutment. These data were statistically analyzed in order to find possible correlation between the deformation generated, and the internal measures of the framework and the external measure of the abutments they were screwed on. For this research, a model made of polyurethane with two external hexagon implants, positioned in the areas of teeth 43 and 45 was used. From this model, 12 three-element frameworks were fabricated and divided into 3 groups (n = 4), according to the technique used: (C) conventional Ni-Cr casting; (U) machined zirconia CAD / CAM and (S) laser sintered Co-Cr by CAD / CAM. During application of axial load, the tensions generated were recorded by strain gauges attached to the abutments, and evaluated quantitatively and qualitatively. In general, there was a predominance of compression areas, and the few areas of traction showed low values. The laser sintered group was the only one with compressive forces for all sensors. The milled and conventional groups behaved similarly, differing only in a region. Subsequently, the framework and the abutment were analyzed by confocal microscopy for evaluation of angle, length and height of the inner (framework) and outer (abutment) walls in regions corresponding to the location of strain gauges. For the variable angle, all groups showed similar values among themselves and greater than the abutments. As for the variables length and height, all values were different. Regarding the abutments, the values were higher in height and smaller in length. These results were analyzed by Pearson statistical method, leading to the conclusion that, for some regions, there was correlation between deformation and length, and also deformation and angle. The higher the angle and the smaller the length, the greater the deformation shown.
67

Efeito do parafuso cônico na simulação da mastigação sobre a interface implante/pilar em diferentes relações coroa/implante / Effect of the conical head screw in the mechanical loading on implant/abutment interface in different crown/implant ratio

Isabela Rodrigues Teixeira da Silva 17 May 2016 (has links)
Este estudo tem como objetivo avaliar 2 diferentes desenhos de parafusos de pilares, o parafuso de cabeça quadrada (PCQ) e o parafuso de cabeça cônica (PCC), verificando se em diferentes relações coroa/implante (RCI) haverá mudança no contra-torque após a ciclagem mecânica. Inicialmente a área superficial do PCQ e do PCC foi mensurada através da análise digital das imagens dos parafusos no software de projeto 3D SolidWorks. Foram utilizados 40 conjuntos Implante/Parafuso/Pilar, os conjuntos foram divididos em 4 grupos: GRUPO A: 10 conjuntos com pilares medindo 9,8mm de altura, simulando uma RCI>1, fixados com PCQ; GRUPO B: 10 conjuntos com pilares medindo 6,0mm de altura, simulando uma RCI<1, fixados com PCQ; GRUPO C: 10 conjuntos com pilares medindo 9,8mm de altura, simulando uma RCI>1, fixados com PCC e GRUPO D: 10 conjuntos com pilares medindo 6,0mm de altura, simulando uma RCI<1, fixados com PCC. Os 40 conjuntos foram fixados em resina acrílica a uma angulação de 30º em relação ao longo eixo. Os pilares foram fixados aos implantes aplicando um torque de aperto de 35Ncm. Os conjuntos foram posicionados na máquina de ensaios de simulação de mastigação que opera com cargas de 100Ncm e cada grupo foi ciclado até atingir 1.0x106 ciclos. Os contra-torques dos parafusos foram aferidos em torquímetro digital para todos os grupos em 2 momentos (pré-ciclagem mecânica e pós-ciclagem mecânica). Para analisar os resultados a metodologia estatística de ANOVA (nível de significância de p <= 0,05) foi utilizada, seguida de comparações múltiplas de Tukey. Na mensuração da área superficial dos parafusos verificou-se que o PCC apresenta maior área de contato entre a interface pilar/parafuso (4,16 mm²) do que o PCQ (1,76 mm²). Avaliando os fatores testados e os p-valores observou-se que o PCQ é diferente estatisticamente do PCC (p-valor <0,0001), independente do momento de avaliação, sendo que a porcentagem de contra-torque é maior para PCC (90,6%) do que para PCQ (80,9%); a RCI>1 não difere estatisticamente da RCI<1 (p-valor 0,1203), apesar da porcentagem de contra-torque ser menor para RCI>1 (84,6%) do que para RCI<1 (86,8%) e o momento pré-ciclagem mecânica diferente estatisticamente do momento pós-ciclagem mecânica (p-valor <0,0001), sendo que na pré-ciclagem a média de porcentagem do contra-torque é maior (92,5%) do que na pós-ciclagem (78,9%). Baseado nos resultados e dentro das limitações do presente estudo, podemos concluir que o PCC apresenta desempenho superior ao PCQ, no que se diz respeito a afrouxamento, o que caracteriza o PCC como uma possibilidade de melhoria em sistemas de implantes de conexão hexagonal externa. Foi possível concluir também que o desenho cônico do PCC influencia no contra-torque após a ciclagem mecânica, sendo indicado sobretudo em uma situação de RCI>1, onde o parafuso é mais requisitado. / The aims of this study is to evaluate two different abutment screws designs, a flat head screw (FHS) and a conical head screw (CHS), making sure if different crown/implant ratio (CIR) result changes in the removal torque after mechanical cycling. Initially, the surface area of the FHS and a CHS was measured by digital image analysis of the screws in 3D SolidWorks Software. Forty sets implant/screw/abutment were used, the sets were divided into 4 groups: GROUP A: 10 sets with abutments 9,8mm height, simulating a CIR>1, fixed with FHS; GROUP B: 10 sets with abutments 6,0mm height, simulating a CIR<1, fixed with FHS; GROUP C: 10 sets with abutments 9,8mm height, simulating a CIR>1, fixed with CHS and GROUP D: 10 sets with abutments 6,0mm height, simulating a CIR<1, fixed with CHS. The sets were fixed in acrylic resin angled 30 ° to the long axis. The abutments were fixed to the implants by applying a torque of 35Ncm. The sets were mechanically loaded. The peak load was 100Ncm vertical force and each group was performed for 1,0x106 cycles. The preload and the postload reverse toque was measured with the digital torque meter and recorded. To analyze the results the methodology of ANOVA (significance level of p <= 0, 05) was used followed by Tukey multiple comparisons. In measuring the surface area of the screws, we found that CHS has greater contact area in the abutment/screw interface (4,16mm²) compared to FHS (1,76mm²). Evaluating the factors tested and p-values we have statistically difference between FHS and CHS (p- value < 0,0001), regardless the time of evaluation, the percentage of CHS reverse torque (90,6 %) is higher than FHS reverse torque (80,9%); CIR>1 and CIR<1 does not differ statistically (p-value 0,1203), although the percentage of reverse torque CIR>1 (84,6 %) is smaller than the percentage of reverse torque CIR<1 (86,8%) and the mechanical preload time differ statistically mechanical postloading time (p-value<0,0001 ), whereas the reversal torque in preload time (92,5%) is largest than reversal torque in postloading time (78,9 %). Based on the results and within the limitations of this study, we can conclude that the CHS outperform the FHS, as regards loosening, which features the CHS as a possible improvement in external-hex implants connections. It was also possible to conclude that the CHS design influences the reverse torque after the mechanical loading, being particularly suitable in a situation CIR>1, where the screw is most required.
68

Influência do material de infraestrutura e do desajuste vertical de próteses parciais fixas implantossuportadas nas tensões transmitidas às estruturas protéticas e ao tecido ósseo peri-implantar / Influence of framework material and vertical misfit of implant-suported partial prostheses on the stresses in prosthetic structures and peri-implant bone tissue

Bacchi, Ataís, 1986- 19 August 2018 (has links)
Orientador: Rafael Leonardo Xediek Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-19T19:18:16Z (GMT). No. of bitstreams: 1 Bacchi_Atais_M.pdf: 865962 bytes, checksum: 55e25bc8a48c9b1870a41c704082365a (MD5) Previous issue date: 2012 / Resumo: O objetivo neste estudo foi avaliar a influência do material de infraestrutura e diferentes níves de desajuste vertical na concentração de tensões em prótese parcial fixa implantossuportada (infraestrutura e porcelana de cobertura), parafuso de retenção e tecido ósseo peri-implantar durante o assentamento protético e frente à aplicação de carga oclusal. Um modelo tridimensional de elementos finitos de uma porção posterior de mandíbula contendo dois implantes osseointegrados nas posições de segundo pré-molar e segundo molar, suportando uma prótese parcial fixa foi construído utilizando software específico de modelagem (SolidWorks 2010). Modelos de elementos finitos foram obtidos pela importação do modelo sólido ao software de simulação mecânica (ANSYS Workbench 11). Os modelos foram separados em grupos de acordo com o material de infraestrutura (liga de ouro tipo IV, liga de prata-paládio, titânio comercialmente puro, liga de cobalto-cromo ou zircônia) e o nível de desajuste vertical (10 ?m, 50 ?m e 100 ?m) criado na interface prótese-implante do segundo pré-molar. A concentração de tensões foi avaliada nas seguintes condições: (1) assentamento protético; e (2) cargas oclusais simultâneas de 110 N vertical e 15 N horizontal em cada dente. Os resultados obtidos mostraram que as infraestruturas mais rígidas apresentam maior concentração de tensões internas; entretanto, promoveram menores concentrações de tensão sobre a porcelana de recobrimento, em ambas condições avaliadas. Na análise do assentamento protético, materiais mais rígidos para infraestruturas aumentaram os valores de tensão no parafuso de retenção e não causaram diferença relevante nas tensões no tecido ósseo peri-implantar. Quando a carga foi aplicada, o uso de infraestruturas mais rígidas promoveu redução de tensões no parafuso de retenção e no tecido ósseo peri-implantar. Em ambas condições avaliadas um considerável aumento na concentração de tensões foi obsevado em todas as estruturas com a amplificação do desajuste. Nas diferentes simulações, o material de infraestrutura exerceu considerável influência nas tensões transmitidas às estruturas avaliadas, exceto ao tecido ósseo peri-implantar em condições de assentamento. Aumento de tensões em todas as estruturas pode ser observado com o aumento do desajuste / Abstract: The aim in this study was to evaluate the influence of the framework material and vertical misfit on the stresses created in an implant-supported partial prosthesis (framework and porcelain veneer), retention screw and peri-implant bone tissue during the settlement of the prosthesis and under load conditions. A 3-D Finite Element model of a posterior part of a jaw with two osseointegrated implants at the place of the right second pre-molar and second molar supporting an implant-supported fixed partial prosthesis was constructed using specific modeling software (SolidWorks 2010). Finite element models were obtained by importing the solid model into mechanical simulation software (ANSYS Workbench 11). The models were divided into groups according to the framework material (type IV gold alloy, silver-palladium alloy, commercially pure titanium, cobalt-chromium alloy or zirconia) and vertical misfit level (10 ?m, 50 ?m and 100 ?m) created at the second pre-molar implant-prosthesis interface. The stress concentration was evaluated in the following conditions: (1) settlement of the prosthesis; and (2) simultaneous loads of 110 N vertical and 15 N horizontal in each tooth. The obtained results showed that stiffer frameworks presented higher stress concentrations in it and led to lower stresses in the porcelain veneer, in both conditions. In the analysis of settlement of the prosthesis, stiffer framework materials increased the stress values in the retention screw and did not cause a relevant difference in the stresses values in peri-implant bone tissue. When the load was applied, the use of more stiffness frameworks led to lower stresses in the retention screw, and peri-implant bone tissue. In both conditions evaluated, considerable raise of stress concentration was observed in all the structures within misfit amplification. Comparing the results of the different simulations, the framework materials presented a considerable influence on the stress concentration in the structures evaluated, except on the peri-implant bone tissue during the settlement of the prosthesis, while a considerable increase of the stress in all the structures was observed with the increase of the misfit / Mestrado / Protese Dental / Mestre em Clínica Odontológica
69

Avaliação da precisão de diferentes técnicas para obtenção de modelos de trabalho de próteses implantorretidas / Evaluation of different cast techniques accuracy for implant-retained prosthesis

Rodrigues, Mariana Agustinho, 1987- 19 August 2018 (has links)
Orientador: Guilherme Elias Pessanha Henriques / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-19T22:04:29Z (GMT). No. of bitstreams: 1 Rodrigues_MarianaAgustinho_M.pdf: 1199483 bytes, checksum: a7e857503f4eeab6a93e110c0445bc98 (MD5) Previous issue date: 2012 / Resumo: O intuito deste trabalho foi comparar diferentes técnicas de preenchimento do molde com gesso e verificar uma metodologia que fosse precisa o bastante para o julgamento das técnicas. Foram obtidos 40 modelos de gesso a partir de uma matriz metálica simulando uma situação clinica de prótese fixa implantorretida de três elementos. Os 40 modelos foram confeccionados segundo quatro técnicas de preenchimento do molde com gesso tipo IV (n=10), sendo assim foram obtidos os seguintes grupos: Grupo 1- 10 modelos de trabalho a partir do preenchimento do molde com gesso em porção única; Grupo 2- 10 modelos de trabalho obtidos a partir do preenchimento do molde com gesso em duas porções; Grupo 3- 10 modelos de trabalho obtidos segundo a técnica do manguito; Grupo 4- 10 modelos de trabalho obtidos a partir do preenchimento do molde com gesso realizando-se a união prévia dos análogos com haste metálica. Foi confeccionada estrutura metálica em titânio utilizada para mensurar os dejasustes marginais e tensão. Os desajustes verticais foram avaliados por meio de observação de desajuste marginal em microscópio com aumento de 120X e 0,1?m de precisão segundo protocolo do parafuso único para teste de passividade em estruturas implantorretidas. A análise de tensão ocorrida sobre a barra metálica foi avaliada por extensometria pela adaptação de dois strain gauges. Os dados foram submetidos à análise variância (ANOVA-1 fator), seguidos de teste de Tukey (?=0,05) para comparação entre os grupos. Foi avaliado presença de correlação entre tensão e desajuste vertical utilizando-se teste de Pearson. Não houve diferença estatística entre as técnicas de preenchimento do molde avaliadas quando comparados os valores de desajuste marginal (p=0,979), entretanto, quando se compara os valores médios de tensão sobre a barra, foi observado diferença estatística significante entre as técnicas do manguito e da união rígida dos análogos de implante (p=0,027). Desta forma, a técnica de união rígida dos análogos previamente a moldagem apresentou resultados similares à técnica convencional e uma técnica adequada para obtenção de modelos de trabalho. A utilização de strain gauges mostrou-se adequada para a avaliação de tensões ocorridas sobre a barra e comparação entre as técnicas de obtenção de modelos de gesso. Não houve correlação entre desajuste marginal e tensão ocorrida na barra / Abstract: The aim of this study was to evaluate the precision of four different mold filling techniques and verify an accurate methodology to evaluate these techniques. It was obtained 40 casts using four from a metallic matrix simulating three unit implant retained prosthesis. The molds were filled using four different techniques (n=10) following the four groups (n=10): Group 1- casts obtained with a single portion filling technique; Group 2- by using a two-step filling technique; Group 3- by using the latex cylinder technique; Group 4- by joining the implant analogues previously to the mold filling. A titanium framework was obtained used as reference to evaluate the marginal misfit and tension forces in each cast. The vertical misfit was measured with an optical microscope with an increase of 120 times following the single screw test protocol. The strain was quantified using strain gauges. Data were analyzed by ANOVA- 1 way and Tukey test (?=0,05). The correlation presence between strain and vertical misfit was evaluated by Pearson test. The misfit values did not present statistic difference (p=0,979). The strain results showed statistic difference between groups 3 and 4 (p=0,027). The splinting technique was considered as efficient as the conventional technique. The strain gauges methodology was accurate on strain measurements and cast distortion evaluation. There was no correlation between strains and marginal misfit / Mestrado / Protese Dental / Mestre em Clínica Odontológica
70

Análise da força de retenção de cimentos resinosos em modelo representativo da técnica de cimentação passiva para implantes osseointegráveis / Analysis of resin cement retention strength in a representative model of passive cementation technique for osseointegration implants

Falcão Filho, Hilmo Barreto Leite 29 June 2009 (has links)
O objetivo deste estudo foi analisar a força de retenção de dois cimentos resinosos utilizados na técnica de cimentação passiva para implantes osseointegráveis, Panavia F e RelyX U100, avaliando essa propriedade na sua aplicação em espécimes de três tipos de diferentes metais, NiCr (Verabond 2, Aalba Dental), NiCrTi (Tilite Ômega, Talladium) e Titânio (Ti c.p., grau 2, Realum), submetidos ou não à termociclagem. Noventa e seis cilindros calcináveis (Conexão Sistemas de Próteses) foram encerados de forma padronizada, fundidos (32 cilindros em cada tipo de liga) e cimentados sobre cilindros de titânio (Conexão Sistemas de Próteses). Os corpos-de-prova foram distribuídos em 12 grupos (n = 8) de acordo com o tipo de liga, cimento e ciclagem térmica. Todos os espécimes foram submetidos a imersão em água destilada a 37º C por 24 horas, entretanto apenas metade deles a um ensaio de termociclagem em uma máquina de simulação de ciclos térmicos MSCT-3 por 5000 ciclos durante 30 dias. Todos os corpos-de-prova foram submetidos a ensaios de tração em uma máquina de ensaios mecânicos EMIC-DL2000 (velocidade = 5mm / min e célula de carga = 500 Kgf ). A análise estatística evidenciou resistência de união à tração do cimento RelyX U100 superior ao cimento Panavia F, independente do tipo de metal utilizado, com médias de até 71,18 Kgf e 55,08 Kgf respectivamente. O ensaio de termociclagem não exibiu interferência na resistência de união de ambos cimentos. / The aim of this study was to analyze the bond strength of two resin cements used in the passive cementation technique for osseointegrated implants, Panavia F and RelyX U100, evaluating this property on its application in specimens of three different metal types, NiCr (Verabond 2, Dental Aalba), NiCrTi (Tilite Omega, Talladium) and Titanium (Ti c.p., degree 2, Realum), submitted or not to termocycling assay. Ninety six calcined cylinders (Conexão Sistemas de Próteses) had been waxed of standardized form, casted (32 in each type of league) and cemented on titanium cylinders (Conexão Sistemas de Próteses). The specimens were distributed enter 12 groups (n = 8) in accordance with the type of metal, cement and thermocycling. All specimens were submitted to an immersion in distilled water at 37ºC for 24 hours, however only half of them to a termocycling assay in a simulation thermal cycles machine MSCT-3 for 5000 cycles during 30 days. All specimens were submitted to a tensile test in a mechanical test machine EMIC-DL2000 (speed = 5mm/min and cell load = 500Kgf). The statistics analysis evidenced tensile strength of the RelyX U100 cement greater than Panavia F cement independent of the metal league type used with averages until 71,18 Kgf and 55,08 Kgf respectively. The termocycling assay did not show interference in the tensile strength of both cements.

Page generated in 0.0266 seconds