• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 274
  • 6
  • 6
  • 6
  • 6
  • 5
  • 4
  • 2
  • Tagged with
  • 283
  • 151
  • 150
  • 98
  • 82
  • 70
  • 69
  • 48
  • 45
  • 42
  • 39
  • 37
  • 33
  • 33
  • 32
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Multiplicidade global de soluções positivas de um sistema elíptico semilinear via métodos topológicos

Alves, Ricardo Lima 21 March 2014 (has links)
Dissertação (mestrado)—Universidade de Brasília, Instituto de Ciências Exatas, Departamento de Matemática, 2014. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2014-06-03T14:52:24Z No. of bitstreams: 1 2014_RicardoLimaAlves.pdf: 788566 bytes, checksum: 5c890ae865c0d1000f7b682e6325eafc (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2014-07-02T14:11:07Z (GMT) No. of bitstreams: 1 2014_RicardoLimaAlves.pdf: 788566 bytes, checksum: 5c890ae865c0d1000f7b682e6325eafc (MD5) / Made available in DSpace on 2014-07-02T14:11:07Z (GMT). No. of bitstreams: 1 2014_RicardoLimaAlves.pdf: 788566 bytes, checksum: 5c890ae865c0d1000f7b682e6325eafc (MD5) / Neste trabalho, utilizaremos o Grau Topológico de Leray-Schauder, um Teorema de Índice de Ponto Fixo em cone, um Teorema de sub-supersolução e o método de blow-up para provar um resultado de Multiplicidade Global de Soluções Positivas para uma classe de sistemas elípticos semilineares de equações diferenciais parciais. ______________________________________________________________________________ ABSTRACT / In this work we use the Leray-Schauder Topological degree, a Fixed Point Index theorem in cones, a sub-supersolution theorem and the blow-up method to prove a global result of Multiplicity of Positive Solutions for a class of semilinear elliptic systems of partial di erential equations.
32

Sêmen refrigerado bovino reduz os danos espermáticos e aumenta a taxa de prenhez na IATF? / Does the bovine cooled semen reduces sperm damage and increases the pregnancy rate in the FTAI?

Tarragó, Octavio Fabián Bao 22 February 2017 (has links)
O objetivo do presente estudo foi avaliar a viabilidade da refrigeração do sêmen bovino comparada com a criopreservação. Este estudo foi realizado em dois experimentos. No primeiro experimento foram comparados os efeitos in vitro do sêmen refrigerado em três meios diluidores comerciais a 5° C por até 48 horas, e criopreservado em dois meios. Para este experimento foram utilizados ejaculados de 10 touros da raça Nelore. Cada ejaculado foi dividido em três alíquotas, sendo diluídas nos meios Botubov®, Steridyl® e Bovidyl®. Após a diluição o sêmen foi envasado em palhetas e refrigerado nos três diluidores e criopreservado utilizando somente os meios Botubov® e Steridyl®. A refrigeração do sêmen foi realizada a 5° C por até 48 horas em sistema passivo de refrigeração BotuFlex® e a criopreservação realizada em sistema automatizado TK 4.000®. O sêmen foi avaliado nos tempos 0, 24, 36 e 48 horas após a refrigeração e após a descongelação, para cada diluidor. Foram realizadas análises dos padrões de cinética espermática pelo sistema computadorizado de análise espermática (CASA, programa SCA - Sperm Class Analyser), integridade das membranas plasmática e acrossomal, potencial de membrana mitocondrial e estresse oxidativo por sondas fluorescentes, sob microscopia de epifluorescência e morfologia espermática por microspcopia de contraste de interferência diferencial (DIC). Notou-se efeito de tempo de refrigeração para os três diluidores para de 0 para 24h, se mantendo semelhante até 48 h. Os diluiores Botubov® e Steridyl® preservaram as características espermáticas de forma semelhante até 48 horas de refrigeração diferindo apenas na variável de velocidade curvilianear; no entanto, ambos foram superiores ao diluidor Bovidyl®, para as variáveis, motilidade total, motilidade progressiva, células rápidas, velocidade curvilinear, velocidade progressiva, velocidade do trajeto, retilinearidade, integridade da membrana plasmática, alto potencial de mitocondrial e espermatozoides com membranas plasmática e acrossomal íntegras e alto potencial mitocondrial. O segundo experimento foi realizado, baseado nos resultados do primeiro experimento, para avaliar os efeitos da refrigeração e da criopreservação do sêmen sobre a fertilidade in vivo. Foram utilizados ejaculados de três touros das raças Brangus, Braford e Angus, com idade entre 5 e 7 anos. O sêmen foi colhido por meio de vagina artificial, o ejaculado foi dividido em três alíquotas, sendo duas alíquotas para refrigeração e uma para criopreservação. Para a refrigeração o sêmen foi diluído nas concentrações de 15x106 (R15) e 30x106 (R30) espermatozoides/palheta e para a criopreservação diluído na concentração de 30x106 espermatozoides/palheta (CRIO). Para todas as diluições foi utilizado o meio Botubov® e o sêmen armazenado em palhetas de 0,5 mL. A refrigeração foi realizada a temperatura de 5° C por 48 horas em sistema passivo de refrigeração BotuFlex® e a criopreservação em sistema automatizado TK®. Foram sincronizadas 552 vacas da raça Brangus em programas de inseminação artificial em tempo fixo. Os resultados da taxa de prenhez para os grupos de vacas inseminadas foram de 49,4% para R15, 43,38% para R30 e 47,59% para o sêmen criopreservado. Pode-se concluir que a refrigeração do sêmen a 5° C por 48 horas resulta em taxa de prenhez semelhante às obtidas com o sêmen criopreservado, sendo que esses resultados indicam que a refrigeração por até 48 horas pode ser uma opção de uso para IATF. / The objective of the present study was to evaluate the viability of cooling bovine semen compared to cryopreservation. This study was carried out in two experiments. In the first experiment, the in vitro effects of cooled semen were compared in three commercial extenders at 5° C for up to 48 hours, and cryopreserved in two extender. For this experiment were used ejaculates of 10 Nellore bulls. Each ejaculate was divided into three aliquots, being diluted in the Botubov®, Steridyl® and Bovidyl® extenders. After dilution, the semen was cooled into three extenders and cryopreserved using the Botubov® and Steridyl®. Semen refrigeration was performed at 5° C for up to 48 hours in BotuFlex® passive refrigeration system and cryopreservation performed in TK 3.000® automated system. Semen was evaluated at 0, 24, 36 and 48 hours after refrigeration and after thawing, for each diluent. The sperm kinetics of the spermatic kinetics (CASA, SCA - Sperm Class Analyzer), plasma and acrosomal membrane integrity, mitochondrial membrane potential and oxidative stress by fluorescent probes were analyzed under epifluorescence microscopy and sperm morphology By Differential Interference Contrast Microscopy (DIC). The Botubov® and Steridyl® diluents were very similar after 48 hours of cooling differing significantly only in the Curvilianear Velocity (VCL) 106.04 m/s and 124.56 m/s. The Bovidyl® diluent yielded results significantly lower than the 48 hours of refrigeration for the variables: total motility (MT), progressive motility (MPRO), fast cells (RAP), curvilinear velocity (VCL), progressive velocity (AP), plasma membrane integrity (PI), high mitochondrial potential (AP), and spermatozoa with intact plasma and acrosomal membranes and high mitochondrial potential (PIAIA). The second experiment was carried out, based on the results of the first experiment I, to evaluate the effects of cooled and cryopreservation of semen on in vivo fertility. We used ejaculates of three bulls of the Brangus, Braford and Angus breeds of a IA center, aged between 5 and 7 years. The semen was collected by artificial vagina, the ejaculate was divided into three aliquots, two aliquots for refrigeration and one for cryopreservation. For cooling, the semen was diluted in the concentrations of 15x106 (R15) and 30x106 (R30) spermatozoa/straw, for cryopreservation diluted in the concentration of 30x106 spermatozoa / vane (CRIO). For all dilutions, the Botubov® medium and the semen stored in 0.5 mL vial were used. Refrigeration was carried out at a temperature of 5° C for 48 hours in BotuFlex® passive refrigeration system and cryopreservation in an automated TK® system. 552 Brangus cows were synchronized in fixed-time artificial insemination programs. The results of the pregnancy rate for the groups of inseminated cows were 49.4% for R15, 43.38% for R30 and 47.59% for cryopreserved semen. It can be concluded that the cooling of the semen at 5° C for 48 hours results in pregnancy rate similar to those obtained with cryopreserved semen, and these results indicate that refrigeration for up to 48 hours may be an option of use for FTAI.
33

Sincronização da ovulação para a inseminação artificial em tempo fixo (IATF) durante a estação reprodutiva desfavorável em fêmeas bubalinas / Synchronization of ovulation for fixed-time artificial insemination (FTAI) during the off breeding season in buffalo.

Porto Filho, Roberto Mendes 29 September 2004 (has links)
Foram comparadas diferentes doses de eCG e hCG associadas a dispositivos intravaginais de progesterona (DIV), para avaliar o crescimento folicular e a ovulação, bem como a taxa de prenhez após a IATF e a funcionalidade do CL 12 dias após a sincronização em búfalas, durante a estação reprodutiva desfavorável. Para tanto, foram realizados cinco experimentos. Nos experimentos 1, 2 e 4, os grupos foram estabelecidos em função da ciclicidade dos animais, avaliada pelas concentrações plasmáticas de progesterona mediante colheita de sangue por punção da veia jugular no D-10 e no D0. Nos experimentos 3 e 5, os grupos foram estabelecidos em função da condição corporal e da ordem de parto. Em todos os experimentos as búfalas receberam um DIV associado a 2mg de Benzoato de Estradiol (BE) no D0. No D9 o DIV foi retirado, e procedeu-se à administração de 0,150mg de prostaglandina (PGF). No experimento 1, as búfalas do G1 (Controle, n=9) e do G2 (eCG, n=10) receberam 1500UI de hCG no D11; o G2 recebeu também 500UI de eCG no D-9; a IATF foi realizada no D12. Nesse experimento, o diâmetro máximo do folículo dominante (DMFD) foi de 12,6 ± 3,0 e 13,4 ± 1,7mm para o G1 e o G2, respectivamente (P>0,05); o diâmetro do folículo ovulatório (DFO) foi de 14,9 ± 2,9 (G1) e de 14,0 ± 1,6mm (G2; P>0,05); o intervalo entre a retirada do DIV e a ovulação (IROV) foi de 78,0 ± 12 (G1) e 68,0 ± 9,0h (G2; P>0,05); a taxa de ovulação (TO) foi de 44,4 (G1) e 70,0% (G2; P> 0,05). A área do CL (ACL) foi de 31,6 ± 19,9 (G1) e de 29,9 ± 9,7mm2 (G2; P>0,05); a concentração plasmática de P4 (P4) foi de 1,3 ± 1,4 (G1) e 2,0 ± 1,6ng/ml (G2; P>0,05); a taxa de prenhez (TP) foi de 22,2 (G1) e 60% (G2; P=0,11). No experimento 2, as búfalas do G1 (1500 UI de hCG; n=21) e do G2 (1000UI de hCG; n=21) receberam 500UI de eCG no D9; no D11, o G1 recebeu 1500UI de hCG e o G2 1000UI de hCG. Os resultados desse experimento são relatados a seguir: DMFD de 12,4 ± 2,3 (G1) e 12,2 ± 2,5mm (G2; P>0,05); DFO de 12,6 ± 2,3 (G1) e 12,5 ± 2,7mm (G2; P>0,05); IROV de 67,7 ± 18,1 (G1) e 72,8 ± 16,7h (G2; P>0,05); TO de 67,7 (G1) e 67,7% (G2; P>0,05); ACL de 24,8 ± 9,2 (G1) e 28,3 ± 17,2mm2 (G2; P>0,05); P4 de 2,3 ± 1,4 (G1) e 2,4 ± 1,3ng/ml (G2; P>0,05). No experimento 3, os animais foram tratados de forma idêntica àqueles do experimento 2, porém as búfalas do G1 (n=83) e do G2 (n=91) receberam a IATF no D12. Nesse experimento, foi obtida TP de 53 (G1) e de 53,8% (G2; P>0,05). No Experimento 4, as búfalas do G1 (n=10) receberam 500UI e as do G2 (n=11) 400UI de eCG; os dois grupos receberam 1000UI de hCG no D11. Esse experimento teve como resultados: DMFD de 13,2 ± 1,4 (G1) e 13,8 ± 1,8mm (G2; P>0,05); DFO de 13,7 ± 1,1 (G1) e 14,2 ± 1,5mm (G2; P>0,05); IROV de 71,1 ± 11,7 (G1) e 75,0 ± 5,5h (G2; P>0,05); TO de 70,0 (G1) e 72,7% (G2; P>0,05); ACL de 28,4 ± 8,6 (G1) e 31,6 ± 10,3mm2 (G2; P>0,05); P4 de 2,7 ± 1,2 (G1) e 3,3 ± 2,9ng/ml (G2; P>0,05). No experimento 5 (G1/n=54; G2/n=51) foi adotado o mesmo protocolo do experimento 4, porém as búfalas receberam a IATF no D12. Esse experimento resultou em TP de 42,6 (G1) e 43,1% (G2; P>0,05). Assim, foi possível concluir que as concentrações de 400UI de eCG e de 1000UI de hCG, associadas ao DIV, foram suficientes para induzir o crescimento folicular, a ovulação e a prenhez em búfalas durante o período reprodutivo desfavorável. / Different dosage of eCG and hCG were compared in association to progesterone intravaginal device (IVD) in female buffalo during the off breeding season with the purpose of evaluating the follicular growing and ovulation as well as the pregnancy rate after FTAI and functionality of the CL, twelve days after the synchronization. For this, 5 experiments were done. For the establishments of the groups in the experiments 1,2 and 4 blood samples were collected for the analysis of plasmatic concentrations of P4 on D -10 and D0 to verify the cyclicity. In the experiments 3 and 5 the groups were established due body condition score and number of calving. In all the experiments the buffaloes received a IVD associated with 2mg of estradiol benzoate (EB) on D0. On D9 the IVD was extracted and it was followed by the administration of 0,150mg of prostaglandin (PGF). In the exp. 1 the buffaloes of G1 (control, n=9) and G2 (eCG, n=10) received 1500IU of hCG on D11. On G2 was administrated 500IU of eCG on D9. The FTAI was done on D12. The maximun diameter of dominant follicle (MDDF) was 12.6 ± 3.0 and 13.4 ± 1.7mm to the G1 and G2, respectively (P>0,05). The diameter of the ovulatory follicle (DOF) was 14.9 ± 2.9 (G1) and 14.0 ± 1.6mm (G2; P>0,05). The interval between the device withdrawn and ovulation (DWO) was 78.0 ± 12.0 (G1) and 68.0 ± 9.0h (G2; P>0,05). The ovulation rate (OR) was 44.4 (G1) and 70.0% (G2; P>0,05). The CL area (CLA) was 31.6 ± 19.9 (G1) and 29.9 ± 9.7mm2 (G2; P>0,05). The plasmatic concentration of P4 (P4) was 1.3 ± 1.4 (G1) and 2.0 ± 1.6ng/ml (G2; P>0,05). The pregnancy rate (PR) was 22.2 (G1) and 60% (G2; P=0,11). In the exp. 2 the buffalo females of G1 (1500IU of hCG; n=21) and G2 (1000IU of hCG; n=21) received 500IU of eCG on D9. On D11, G1 received 1500IU of hCG and G2 1000IU of hCG. The MDDF was 12.4 ± 2.3 (G1) and 12.2 ± 2.5mm (G2; P>0,05), the DOF was 12.6 ± 2.3 (G1) and 12.5 ± 2.7mm (G2; P>0,05), DWO was 67.7 ± 18.1 (G1) and 72.8 ± 16.7h (G2; P>0,05), the OR was 67.7 (G1) and 67.7% (G2; P>0,05), the CLA was 24.8 ± 9.2 (G1) and 28.3 ± 17.2mm2 (G2; P>0,05) and the P4 was 2.3 ± 1.4 (G1) and 2.4 ± 1.3ng/ml (G2; P>0,05). The exp. 3 was identical to exp.2, although the animals of G1 (n=83) and G2 (n=91) received the FTAI on D12. The PR was 53.0 (G1) and 53,8% (G2; P>0,05). In exp. 4, the animals of G1 (n=10) received 500IU and G2 (n=11) 400IU of eCG. Both groups received 1000IU of hCG on D11. The MDDF was 13.2 ± 1.4 (G1) and 13.8 ± 1.8mm (G2; P>0,05), the DOF was 13.7 ± 1.1 (G1) and 14.2 ± 1.5mm (G2; P>0,05), the DWO was 71.1 ± 11.7 (G1) and 75.0 ± 5.5h (G2; P>0,05), the OR was 70.0 (G1) and 72.7% (G2; P>0,05), the CLA was 28.4 ± 8.6 (G1) and 31.6 ± 10.3mm2 (G2; P>0,05) and the P4 was 2.7 ± 1.2 (G1) and 3.3 ± 2.9ng/ml (G2; P>0,05). In exp. 5 (G1/n=54; G2/n=51) was done the same protocol in the exp. 4, although the animals received the FTAI on D12. The PR was 42.6 (G1) and 43.1% (G2; P>0,05). Dosage of 400IU of eCG and 1000IU of hCG, associated to IVD for FTAI were enough to induce follicular growing, ovulation and pregnancy in buffalo females during the off breeding season.
34

Estudo comparativo das alterações do tratamento da má oclusão de classe II com os aparelhos propulsores Jasper Jumper e Twin Force Bite Corrector, associados ao aparelho fixo / Comparative study of changes in the treatment of Class II malocclusion devices with propellants Jasper jumper and Twin Force Bite Corrector, associated with fixed appliance

Fontes, Fernanda Pinelli Henriques 09 May 2016 (has links)
O objetivo desta pesquisa foi comparar as alterações cefalométricas de pacientes com má oclusão de Classe II divisão 1, tratados com os aparelhos Jasper Jumper e Twin Force Bite Corrector, associados ao aparelho ortodôntico fixo. A amostra foi composta por 120 telerradiografias em norma lateral de 60 pacientes, os quais foram divididos em 3 grupos: Grupo Experimental 1, constituído por 20 pacientes com idade inicial média de 12,39 anos, tratados por meio do aparelho Jasper Jumper associado ao aparelho fixo, por um período médio de 2,42 anos; Grupo Experimental 2, contendo 20 pacientes com idade inicial média de 11,83 anos, tratados com o aparelho Twin Force associado ao aparelho fixo, com tempo médio de tratamento de 2,59 anos; Grupo Controle, composto por 20 jovens, com idade inicial média de 12,13 anos e observados por um período médio de 2,21 anos. As alterações foram comparadas entre os grupos, por meio da Análise de Variância e do teste de Tukey. Observou-se que ambos os tratamentos apresentaram um efeito restritivo na maxila, houve melhora significante da relação maxilomandibular nos dois protocolos de tratamento avaliados e promoveram rotação horária do plano oclusal. O grupo Jasper Jumper, promoveu uma significante limitação do desenvolvimento vertical dos molares superiores em relação aos outros grupos. Os incisivos inferiores exibiram maior protrusão e uma extrusão dos molares inferiores nos grupos 1 e 2. Ambos os aparelhos melhoraram significantemente a relação maxilomandibular, os trespasses horizontal, vertical e a relação molar. Os protocolos de tratamento promoveram retrusão dos lábios superiores. / The aim of this study was to compare the cephalometric changes in patients with Class II Division 1 malocclusion, treated with the Jasper Jumper and Twin Force Bite Corrector, associated with fixed orthodontic appliances. The sample consisted of 120 lateral cephalometric radiographs of 60 patients, divided into 3 groups: Experimental Group 1 comprised 20 patients with initial mean age of 12.39 years, treated with the Jasper Jumper appliance associated with device fixed for an average period of 2.42 years; Experimental group 2 with 20 patients with initial mean age of 11.83 years, treated with Twin Force unit associated with braces, with an average treatment time of 2.59 years; Control Group, composed of 20 individuals, average initial age of 12.13 years and observed for an average period of 2.21 years. The changes were compared between groups by ANOVA followed by Tukey test. It was observed that both treatments presented a restrictive effect on the maxilla; there was significant improvement in the maxillomandibular relationship in the two treatment protocols groups evaluated and clockwise rotation of the occlusal plane. The Jasper Jumper group, provided a significant limitation of the vertical development of the maxillary molars in relation to other groups. The lower incisors showed greater protrusion and extrusion of mandibular molars in groups 1 and 2. Both appliances provided significant improvement of maxillomandibular relationship, overjet, overbite and molar relationship. Groups 1 and 2 presented retrusion of the upper lip.
35

Avaliação cefalométrica do comportamento dos padrões extremos de crescimento facial no tratamento da Classe II, 1ª divisão com extração de primeiros pré-molares e aparelho fixo associado à ancoragem extrabucal

Hassunuma, Cristina Yuka 20 January 2003 (has links)
O objetivo deste estudo cefalométrico foi avaliar e comparar a influência dos padrões extremos de crescimento facial anterior no tratamento da má oclusão de ¼ à ¾ de Classe II, 1ª divisão. O tratamento ortodôntico compôs-se similar a toda amostra com a extração de quatro primeiros prémolares e o aparelho fixo; porém, diferenciou-se quanto à ancoragem extrabucal, sendo utilizada a tração cervical para jovens com padrão predominantemente horizontal e a tração cérvico-occipital para jovens com padrão predominantemente vertical. O grupo composto pelo aparelho cervical consistiu de 30 jovens (15 masculino e 15 feminino) e o grupo composto por aparelho cérvico-occipital de 30 jovens (15 masculino e 15 feminino). O tempo médio da mecanoterapia total equivaleu-se à 2,51 anos, sendo que a idade média inicial correspondeu-se a 13,02 anos e a final de 15,53 anos. Avaliou-se e comparou-se os resultados de acordo com o teste “t" de Student pareado e não-pareado. Os resultados demonstraram que a extração dos pré-molares não interferiu na dimensão vertical e as mudanças nos valores dos ângulos FMA e SN.GoGn não se apresentaram estatisticamente significantes; porém, as maiores alterações referentes às medidas NAP e a relação maxilomandibular apresentaram resultados estatisticamente significantes entre os grupos. / The aim of this cephalometric study was to evaluate and compare the influence of extreme anterior facial growth patterns on the treatment of patients presenting Class II, division 1 malocclusions. The orthodontic therapy was similar for the entire sample, with extraction of four first premolars and fixed appliance, yet presenting differences as to the type of headgear, namely low-pull headgear for horizontal growers and high-pull headgear for vertical growers. The low-pull headgear group comprised 30 young individuals (15 males and 15 females), as well as the high-pull headgear group (15 males and 15 females). The mean treatment time was 2.51 years, with a mean initial age of 13.02 years and a final mean age of 15.53 years. The intra-group and inter-group changes were evaluated and compared by means of dependent and independent t tests, respectively. Results demonstrated that extraction of premolars did not interfere with the vertical dimension, and the changes in the angles FMA and SN.GoGn did not present statistically significant changes within each group. However, changes in NAP and in the maxillomandibular relationship were statistically different between the groups.
36

Estudo comparativo das alterações do tratamento da má oclusão de classe II com os aparelhos propulsores Jasper Jumper e Twin Force Bite Corrector, associados ao aparelho fixo / Comparative study of changes in the treatment of Class II malocclusion devices with propellants Jasper jumper and Twin Force Bite Corrector, associated with fixed appliance

Fernanda Pinelli Henriques Fontes 09 May 2016 (has links)
O objetivo desta pesquisa foi comparar as alterações cefalométricas de pacientes com má oclusão de Classe II divisão 1, tratados com os aparelhos Jasper Jumper e Twin Force Bite Corrector, associados ao aparelho ortodôntico fixo. A amostra foi composta por 120 telerradiografias em norma lateral de 60 pacientes, os quais foram divididos em 3 grupos: Grupo Experimental 1, constituído por 20 pacientes com idade inicial média de 12,39 anos, tratados por meio do aparelho Jasper Jumper associado ao aparelho fixo, por um período médio de 2,42 anos; Grupo Experimental 2, contendo 20 pacientes com idade inicial média de 11,83 anos, tratados com o aparelho Twin Force associado ao aparelho fixo, com tempo médio de tratamento de 2,59 anos; Grupo Controle, composto por 20 jovens, com idade inicial média de 12,13 anos e observados por um período médio de 2,21 anos. As alterações foram comparadas entre os grupos, por meio da Análise de Variância e do teste de Tukey. Observou-se que ambos os tratamentos apresentaram um efeito restritivo na maxila, houve melhora significante da relação maxilomandibular nos dois protocolos de tratamento avaliados e promoveram rotação horária do plano oclusal. O grupo Jasper Jumper, promoveu uma significante limitação do desenvolvimento vertical dos molares superiores em relação aos outros grupos. Os incisivos inferiores exibiram maior protrusão e uma extrusão dos molares inferiores nos grupos 1 e 2. Ambos os aparelhos melhoraram significantemente a relação maxilomandibular, os trespasses horizontal, vertical e a relação molar. Os protocolos de tratamento promoveram retrusão dos lábios superiores. / The aim of this study was to compare the cephalometric changes in patients with Class II Division 1 malocclusion, treated with the Jasper Jumper and Twin Force Bite Corrector, associated with fixed orthodontic appliances. The sample consisted of 120 lateral cephalometric radiographs of 60 patients, divided into 3 groups: Experimental Group 1 comprised 20 patients with initial mean age of 12.39 years, treated with the Jasper Jumper appliance associated with device fixed for an average period of 2.42 years; Experimental group 2 with 20 patients with initial mean age of 11.83 years, treated with Twin Force unit associated with braces, with an average treatment time of 2.59 years; Control Group, composed of 20 individuals, average initial age of 12.13 years and observed for an average period of 2.21 years. The changes were compared between groups by ANOVA followed by Tukey test. It was observed that both treatments presented a restrictive effect on the maxilla; there was significant improvement in the maxillomandibular relationship in the two treatment protocols groups evaluated and clockwise rotation of the occlusal plane. The Jasper Jumper group, provided a significant limitation of the vertical development of the maxillary molars in relation to other groups. The lower incisors showed greater protrusion and extrusion of mandibular molars in groups 1 and 2. Both appliances provided significant improvement of maxillomandibular relationship, overjet, overbite and molar relationship. Groups 1 and 2 presented retrusion of the upper lip.
37

Análise da secagem de cornichão (Lotus corniculatus L.) em leito fixo com escoamento de ar paralelo

Kanaan, Akel Ferreira 03 September 2014 (has links)
Submitted by Andrea Pereira (andrea.pereira@unipampa.edu.br) on 2017-03-10T16:36:46Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Análise da Secagem de Cornichão-Akel FKanaan.pdf: 1613401 bytes, checksum: 62cca34779fa01d06bb57914687636da (MD5) / Approved for entry into archive by Andrea Pereira (andrea.pereira@unipampa.edu.br) on 2017-03-10T16:37:11Z (GMT) No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Análise da Secagem de Cornichão-Akel FKanaan.pdf: 1613401 bytes, checksum: 62cca34779fa01d06bb57914687636da (MD5) / Made available in DSpace on 2017-03-10T16:37:11Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Análise da Secagem de Cornichão-Akel FKanaan.pdf: 1613401 bytes, checksum: 62cca34779fa01d06bb57914687636da (MD5) Previous issue date: 2014-09-03 / A crescente necessidade da utilização de espécies forrageiras de estação fria na região sul do país vem determinando uma grande demanda por sementes de qualidade. Entre as leguminosas se destaca o cornichão (Lotus corniculatus L.), que é uma leguminosa forrageira oriundo da Europa e da região mediterrânea. Esta leguminosa forrageira tem na versatilidade a sua maior vantagem, visto que apresenta produção de forragem na primavera, no verão e no outono, possui resistência à seca e ao encharcamento temporário do solo e apresenta boa persistência da massa verde. Além disso, as sementes deste tipo de espécie podem ser misturadas com espécies de inverno, o que aumenta o rendimento da matéria seca, dá uma melhor distribuição da forragem ao longo do ano e agrega uma melhora na qualidade das pastagens. Apesar dessas vantagens, as sementes de cornichão comercializadas possuem ainda uma baixa qualidade. Esse fato é decorrente de um sistema de fiscalização ineficiente, associado à dificuldade de produção e beneficiamento do produto. Outro problema que o produtor de sementes desta espécie enfrenta é a dormência tegumentar, isto é, o revestimento da semente (tegumento) é impermeável e não permite que a água necessária para a germinação chegue ao interior da semente. Na literatura, diversos trabalhos têm relatado que cada vez mais há um aumento na demanda de sementes forrageiras em função do melhoramento do campo nativo e das pastagens cultivadas. Diante de um mercado tão promissor, a obtenção de sementes de melhor qualidade ainda apresenta dificuldades que vão desde a fase de produção no campo, onde as sementes são colhidas precocemente em relação ao ponto de maturidade fisiológica devido ao processo de perda natural, até seu beneficiamento, onde o processo de secagem apresenta-se como uma etapa limitante que necessita de uma atenção muito especial para evitar perdas fisiológicas no produto final. De um modo geral, a secagem é definida como a remoção, voluntária ou não, total ou parcial, de uma fase líquida ou gasosa de qualquer material através da transferência de calor e de massa. A secagem tem em sua essência a finalidade de assegurar a conservação de um produto por meio da redução do seu teor de água. No caso de materiais orgânicos, como é o caso de sementes, a redução no teor de água deve ser efetuada até o ponto em que a concentração de açúcares, ácidos, sais e outros componentes, sejam suficientemente elevados para reduzir a atividade de água e inibir, portanto, o desenvolvimento de micro-organismos. Na tecnologia de produção de sementes de alta qualidade a secagem é tida com uma das etapas de maior importância, pois permite a redução do teor de água em níveis adequados para o armazenamento e comercialização (12 a 15 % de umidade), preserva as sementes de alterações físicas e químicas induzidas pelo excesso de umidade, torna possível a manutenção da qualidade inicial durante o armazenamento e possibilita colheitas próximas da maturação fisiológica. Entretanto, o processo de secagem, seja ele qual for, deve acontecer de forma controlada e de maneira uniforme a fim de evitar elevados gradientes de umidade e temperatura no interior do material que podem provocar a perda da qualidade do produto final. De acordo com o que foi exposto, o presente trabalho de mestrado teve como objetivo realizar um estudo sobre o processo de secagem de sementes de cornichão (Lotus corniculatus L.) em um secador de leito fixo com fluxo de ar paralelo. Para alcançar tal objetivo, este trabalho foi dividido nas seguintes etapas: caracterização física e fisiológica das sementes, análise do processo de reumidificação das sementes, estudo das isotermas de dessorção das sementes reumidificadas e avaliação dos efeitos da variação da temperatura, da velocidade do ar e da altura da bandeja sobre a cinética de secagem e qualidade fisiológica do produto final. Os dados experimentais mostraram que os resultados obtidos para a umidade em base úmida das sementes secas ficaram na faixa de 5 % para as secagens realizadas a 60 °C e em aproximadamente 8 % para as secagens realizadas a 40 °C. No que se refere à germinação, os valores encontrados estão na ordem de 44 a 59 % para as secagens realizadas neste estudo. Dentre as secagens, a que obteve o maior valor de germinação, com valor de 59 %, foi a realizada na condição de T = 40 °C, v = 1,0 m/s e h = 1,0 cm. / The growing necessity for the use of cool-season forage species in the southern region of the country has indicated a high demand for quality seeds. Among the legumes, the birdsfoot trefoil (Lotus corniculatus L.) is a forage legume which is originated in Europe and in the Mediterranean region. This versatility in the forage legume has its biggest advantage, since it presents forage production in the spring, summer and autumn, is resistant to drought and temporary waterlogging and shows good persistence of green mass. Furthermore, seeds of such kind can be mixed with winter species, which increases the yield of dry matter, gives a better distribution of the material throughout the year and adds an improvement in the quality of pastures. Despite these advantages, the seeds of birdsfoot marketed still have a poor quality. This fact is a result of an inefficient system of monitoring and difficulties associated to production and processing of the product. Another problem is that the seed producer of this species is facing cutaneous numbness, that is, the seed coat (tegument) is impermeable and does not allow the water, necessary for germination to reache the interior of the seed. In the literature, several studies have reported that there is an increasing demand for an increase in forage seed due to the improvement of native grassland and cultivated pastures. Faced with such a promising market, obtaining better quality seed still presents difficulties ranging from the production phase of the field, where the seeds are harvested early in relation to physiological maturation due to the natural loss process until its processing where the drying process is presented as a limiting step that requires particular attention to avoid losses in physiological final product. In general, drying is defined as the removal voluntary or not, full or partial, of a liquid or gaseous phase of any material by the transfer of heat and mass. Drying has its essence in order to ensure the preservation of a product through reduction of water content. In the case of organic materials, such as seeds, reduction in water content must be performed to the extent that the concentration of sugars, acids, salts and other components are sufficiently high to reduce the water activity and inhibit, therefore, the growth of microorganisms. In the production of high quality seeds the drying technology is seen with one of the most important steps, since it allows reducing the water content suitable for storage and marketing levels (12 to 15% moisture), preserves the seeds from physical changing and chemical induced excess moisture, makes it possible to maintain the initial quality during storage and enables the next harvest physiological maturity. However, the drying process, whatever it may be, should occurs in a controlled and uniform manner in order to avoid high temperature and humidity gradients within the material that could result in loss of quality of the final product. Towards to it, this paper aimed to conduct a study on the drying of seeds of birdsfoot trefoil (Lotus corniculatus L.) in a fixed bed dryer with parallel air flow. To accomplish this goal, this study was divided into the following steps: physical and physiological seed characterization, analysis of rewetting seed process, study of desorption isotherms of the rewetted seeds and evaluation the effects of temperature, air velocity and the height of the tray on the drying kinetics and physiological quality of the final product. The experimental data showed that the results for the dry seeds of UBU were in the range of 5 % to drying carried out at 60 ° C and about 8% to drying carried out at 40 ° C. With regard to seed germination, the values are found in a range of 44 to 59% for the drying carried out in this study. The drying condition whom presented the highest germination value about 59 % was performed on T = 40 ° C, v = 1,0 m/s and h = 1,0 cm.
38

Estudo do desempenho hidrodinâmico de um leito fixo rígido com esferas de vidro sinterizadas para retenção de partículas / Experimental study of hidrodynamics performance of the rigid fix bed produced with spheres of grass for the retention of particles

Beck Junior, Ernesto 10 May 2006 (has links)
Nesta dissertação de mestrado é estudado o desempenho fluidodinâmico de um meio poroso fixo e compactado, construído por sinterização com esferas de vidro para a retenção de partículas. A análise experimental visou o processo de retenção de partículas a partir de pastilhas circulares de diâmetro de 29 mm confeccionadas com esferas de vidro variando de 1,0 a 3,3 mm de diâmetro e sinterizadas como um elemento rígido a partir de aquecimento contínuo até cerca de 750ºC. As pastilhas foram submetidas a diferentes pressões de coluna de água, e a vazão no meio poroso foi analisada para diferentes pressões. Os experimentos foram realizados com a adição em batelada de polpa de açaí, areia fina, areia grossa e esferas de vidro próprias da composição do meio poroso. As vazões mássicas adimensionais são apresentadas graficamente para diferentes pressões de coluna de água variando entre 0,1 e 0,5 atmosferas (atm), em regime permanente e estacionário. Os resultados experimentais foram comparados e apresentados na forma de parâmetros adimensionais que caracterizam o regime de escoamento num leito fixo. Os resultados experimentais foram modelados a partir da modificação dos modelos de Vortmeyer e Schuster (1983) e Subagyo et al. (1998) para estabelecer sobre os mesmos parâmetros adimensionais uma adequada aproximação com os resultados teóricos. / The present dissertation reports the performance of steady flow in circular fix bed which was created by sinterization of glass spheres. The experimental analysis aimed the process of retention of particles from circular packed bed of 29 mm of diameter. The circular fix bed was created with spheres of glass of diameter between 1.0 and 3.0 mm, and made by sintering one rigid body from continuous heating until 750ºC. The circular and rigid fix bed was subjected to different pressures of column of water varying between 0.1 and 0.5 atm for analysis of flux (kg/s). The experiments were carried out with the addition of one amount of açai pulp, sands fine, sands thick and spheres of glass own of composition of fix bed. The dimensionless flux was present for different pressures of column of water on the fix bed; the results were compared and presented in the form of dimensionless parameters of literature what characterize the flow in packed bed. The experimental results were modeled based on Vortmeyer e Schuster (1983) and Subagyo et al. (1998) models, establishing on the dimensionless parameters an appropriate approach with the theoretical flux of circular fix bed.
39

Propriedades de escala e cascatas de bifurcações em mapas unidimensionais discretos /

Mendonça, Hans Muller Junho de. January 2018 (has links)
Orientador: Juliano Antonio de Oliveira / Banca: Edson Denis Leonel / Banca: Tiago Pereira da Silva / Resumo: Neste trabalho estudamos o decaimento das órbitas para os pontos fixos em bifurcações distintas em mapeamentos unidimensionais não lineares discretos. Consideramos o mapa Gauss, analisamos o diagrama de órbitas e estudamos o decaimento das trajetórias para o ponto de equilíbrio nas bifurcações tangente e de duplicação de período. Encontramos analítica e numericamente o conjunto de expoentes críticos que descrevem propriedades de escala nas bifurcações e próximos delas. Estes expoentes caracterizam o tipo de bifurcação do problema. Estudamos, também, eventos chamados crises de fronteiras, que ocorrem a partir de determinado valor do parâmetro de controle $\nu$. Estendemos nossos estudos considerando o mapa Hassell e introduzimos uma perturbação no problema. Assim como no mapa Gauss, analisamos nestes sistemas o diagrama de órbitas, os decaimentos das trajetórias para os pontos fixos nas bifurcações transcríticas e investigamos analítica e numericamente para determinar os expoentes críticos destas bifurcações. Com o intuito de investigar os efeitos da perturbação paramétrica introduzida ao mapa Hassell, construímos e analisamos as trajetórias no espaço de parâmetros. Utilizamos, como ferramentas, as órbitas superestáveis e extremas. Nas duas classes de mapas (Gauss e Hassell), caracterizamos o caos via expoentes de Lyapunov. Mostramos, também que, quando obtidos os expoentes críticos e utilizando transformações de escalas apropriadas nos eixos coordenados, todas as curvas de de... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In this work we study the decay of the orbits to the xed points in di erent bifurcations of nonlinear discrete one-dimensional mappings. We consider the Gauss map and analyze the orbit diagram to study the convergence of the trajectories to the equilibrium point at the fold and ip bifurcation. We nd numerically and analytically the set of critical exponents that describe some scaling properties at the bifurcations and near them. These critical exponents can also characterize which types of bifurcations that arises from the problem in question. We also study particular events called boundary crisis that occur from above a speci c value of the control parameter . We continue the studies considering the Hassell map and its perturbed version. Just like in the Gauss map, we analyze the orbit diagrams within these systems, as well as the convergence of the orbits to the xed points at the transcritical bifurcations, while also investigating numerically and analytically to determine the speci c critical exponents of those bifurcations. With parametric perturbation added to the Hassell map, we build and analyze the trajectories on the parameter space. We apply, as tools, the superstable and extreme orbits. In the two classes of the maps (Gauss and Hassell), we quantify the chaos by Lyapunov exponents. After the critical exponents are obtained, using convenient scale transformations in the coordinate axes we show that all the curves of decay to the xed points are collapsed into a univ... (Complete abstract click electronic access below) / Mestre
40

O índice dos pontos fixos /

Caritá, Lucas Antonio. January 2014 (has links)
Orientador: João Peres Vieira / Banca: Alice Kimie Miwa Libardi / Banca: Ermínia de Lourdes Campello Fanti / Resumo: Este trabalho é espelhado no livro "Teoria do Índice" [1] de Daciberg Lima Gonçalves e José Carlos de Souza Kiihl, publicado em 1983 no 14o Colóquio Brasileiro de Matemática pelo IMPA. Para a leitura deste trabalho é necessário uma familiaridade prévia com Topologia Algébrica, na qual indicamos [2] e [3] para consulta. Inicialmente apresentaremos alguns pré-requisitos algébricos e topológicos necessários para o desenvolvimento do trabalho e a seguir estudaremos: pontos fixos de aplicações contínuas de X em X, em que X é um espaço topológico; Grau de Brouwer de aplicações contínuas de Sn em Sn (ou respectivamente (Bn+1; Sn) em (Bn+1; Sn)); Grau Local de uma aplicação contínua f de V em Sn em torno de um ponto Q 2 Sn, em que V Sn é um aberto e f����1(Q) é um compacto e Índices dos Pontos Fixos de uma aplicação contínua de V em Sn, em que V Rn é um aberto / Abstract: This work is based on the book titled "Teoria do Índice" [1] by Daciberg Lima Gonçalves and José Carlos de Souza Kiihl , published in 1983 in the 14o Brazilian Math Colloquium held by IMPA . In order to perform the reading of this work, a basic acquaintance from the algebraic topology is needed, on which we can indicate the following [2] and [3] references. Firstly, for the development of the work, some previous necessary algebraic and topological requirements are shown and the next topics will be studied: fixed points of continuous maps from X to X, where X is a topological space, Brouwer's degree of continuous maps from Sn to Sn ( or respectively (Bn+1; Sn) to (Bn+1; Sn)), Local Degree of continuous maps from V to Sn around a point Q 2 Sn, where V Sn is an open set and f����1(Q) is a compact set and Fixed Points Index of continuous maps from V to Sn, where V Rn is an open set / Mestre

Page generated in 0.0426 seconds