Spelling suggestions: "subject:"citômetro LED"" "subject:"difratômetro LED""
1 |
Estimativa da irradiância solar ultravioleta horária no semi-árido PernambucanoCesar de Andrade, Ricardo January 2007 (has links)
Made available in DSpace on 2014-06-12T23:17:16Z (GMT). No. of bitstreams: 2
arquivo9152_1.pdf: 3779997 bytes, checksum: a5c404337e5df1d4e13198cbe6dcf0d9 (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2007 / Dois códigos computacionais, SPCTRAL2 e SMARTS2, foram utilizados para
estimar a irradiância solar ultravioleta e o índice de irradiação ultravioleta em uma
localidade do semi-árido do Nordeste do Brasil. Os softwares apresentam simplicidade de
uso, precisão e relativa facilidade na obtenção das variáveis de entrada: ângulo zenital,
pressão atmosférica em relação ao nível do mar, umidade relativa do ar, temperatura do ar,
quantidade de água precipitável, ozônio total e a profundidade ótica de aerossóis (AOD).
Todas essas variáveis são medidas em estações meteorológicas convencionais, exceto a
profundidade óptica dos aerossóis. A profundidade óptica de aerossóis foi medida com um
aparelho construído com um sensor LED (Light-Emitting Diode) de banda estreita,
centrada em 555nm que mede a transmitância da radiação monocromática através da
atmosfera terrestre, a qual pode ser descrita pela lei de Beer.
Para as simulações realizadas a partir da utilização do AOD diário, os resultados das
simulações da irradiância solar ultravioleta mostrou um erro máximo de 6,4% para o meio
dia solar, e um erro máximo entre 10 e 12% para 09:00h da manhã e 15:00h,
respectivamente, quando comparados com os valores medidos com o piranômetro TUVR
|
2 |
Um fotômetro LED-NIR duplo feixe microcontrolado e portátil para análise screening e quantitativa de medicamentos injetáveis de forma não invasiva / A micro-processor controlled and portable dual-beam LED-NIR photometer for noninvasive quantitative and screen analyses of injectable drugsSanches, Fatima Aparecida Castriani 27 September 2013 (has links)
Made available in DSpace on 2015-05-14T13:21:31Z (GMT). No. of bitstreams: 1
arquivototal.pdf: 4300715 bytes, checksum: 6618808ff4fc3b330190a5a4b7fe14f3 (MD5)
Previous issue date: 2013-09-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / In this work, a portable LED - NIR double beam micro-processor controlled photometer
for non-destructive/non-invasive screening and quantitative analysis of injectable medicines
was developed to assess conformity with values established by the Brazilian Pharmacopoeia.
The product analyzed was injectable dipyrone (1g/2 mL) sold in amber colored vials of 1.1 cm
outer diameter, and 6 cm in height. Initially, spectroscopic studies were carried out employing
a commercial spectrophotometer to assess the best NIR spectrum regions that might be used.
The instrument developed used two twin LEDs with NIR radiation emissions rated at 1050 ±
50 nm. Two InGaAs photodiodes (also identical), and a PIC18F455 microcontroller were used
as well. The output of the instrument used a PIC microcontroller coupled to a 20x2 liquid
crystal display which communicated with a PC by USB 2.0 for communication. The instrument
evaluated commercial dipyrone injection samples using absorbance measurements made
directly from ampoules of the injectable medicines. The photometer was calibrated with
standard solutions of dipyrone, and its performance was evaluated by an analysis of 620 of the
commercial dipyrone injection samples, where 320 were expired. The instrument had a high
success rate for screening analysis (91%). For quantitative determination of the active
dipyrone, a linear response was obtained [R2 = 0.9964, A = 0.0068 + 0.0043 C (% w/v)] in the
concentration range of 5 to 60% m/v. We also obtained a low relative error of 0.40%, and good
accuracy in the analyses with a relative standard deviation of 2.13%. / Neste trabalho foi desenvolvido um fotômetro LED-NIR duplo feixe
microcontrolado e portátil para análise screening e quantitativa de medicamentos
injetáveis de forma não destrutiva/não invasiva, visando investigar a conformidade
desses com os valores estabelecidos na Farmacopéia Brasileira. O medicamento
analisado foi a dipirona sódica injetável 1g/2mL, comercializados em ampolas de
coloração âmbar. Foram realizados inicialmente estudos espectroscópicos empregando
um espectrofotômetro comercial para avaliar quais as melhores regiões do espectro NIR
que poderiam ser empregadas para a determinação da espécie de interesse. O
instrumento desenvolvido utiliza dois LEDs-NIR com emissão de radiação nominal em
1050 ± 50 nm gêmeos (de mesmas especificações técnicas), dois fotodiodos de InGaAs
também idênticos e um microcontrolador PIC18F455. Como dispositivos de saída do
instrumento foram empregados o microcontrolador PIC acoplado a um display de cristal
líquido 20x2, o qual também se comunica com um microcomputador portátil por
comunicação USB 2.0. O instrumento foi avaliado com amostras comerciais de dipirona
sódica injetável por medidas de absorbância efetuadas diretamente nas ampolas dos
medicamentos injetáveis. O fotômetro foi calibrado com soluções padrão de dipirona e
seu desempenho foi avaliado na análise de 620 amostras comerciais de dipirona
injetável, das quais 320 apresentavam prazo de validade expirado. O instrumento obteve
elevado índice de acerto para a análise screening (91%). Para determinação quantitativa
do princípio ativo dipirona, uma resposta linear foi obtida [R2 = 0,9964, A = 0,0068 +
0,0043 C (% m/v)] na faixa de concentração de: 5 a 60 % m/v. Também foi obtido um
baixo erro relativo conjunto (0,40 %) e boa precisão nas análises (desvio padrão relativo
conjunto = 2,13%).
|