Spelling suggestions: "subject:"frödingskolan"" "subject:"träningsskolan""
1 |
Analys av elbasnivå för Vålbergsskolan, Karlstads Kommun : Kartläggning av elanvändning nattetid samt undersökning av energieffektiviserande åtgärder. / Analysis of the electricity base level for Vålbergsskolan, Karlstads Kommun : Identification of electricity usage during the night and investigation of energy-efficiency measuresAndersson, Erik January 2011 (has links)
Examensarbetet har gått ut på att ta reda på varför en del skolor i Karlstads kommun, använder olika mycket el under kvällar, helger och nätter. Skillnaderna är stora och på grund av det har ett nytt begrepp, kallat elbasnivå, definierats. I princip är elbasnivån den effekt som används under de tider som lokalerna inte nyttjas. Efter genomförd rangordning av elbasnivån med hjälp av en egenutvecklad excelkalkyl, för ett urval på 15 skolor i Karlstads kommun, valdes två av dessa ut för vidare utredning. En skola med låg elbasnivå och en skola med hög elbasnivå valdes. Frödingskolan är den skola som har lägst elbasnivå och valdes att fungera som en referensbyggnad. Den andra skolan är Vålbergsskolan och den valdes då den hade en av de högsta elbasnivåerna i rangordningen. Gemensamt för båda skolorna är att det inte förekommer någon elvärme i fastigheterna. Dessutom finns ingen större årstidsvariation i skolornas elförbrukning. För Frödingskolan uppmättes en elbasnivå på 2,0 W/m2 och för Vålbergskolan 4,6 W/m2, alltså mer än dubbelt så hög för den sistnämnda. Genom studiebesök och omfattande mätningar har elanvändningen i de båda skolorna kunnat kartläggas. Av de resultat som fåtts har olika åtgärder för att sänka elbasnivån tagits fram. Detta har gjorts för båda skolorna även om Frödingskolan hade en låg elbasnivå från början. Det visade sig att även där fanns det åtgärder som kan sänka elbasnivån. Förslag på åtgärder för Frödingskolan:• Policy för avstängning av datorer efter arbetstid ca 1 kW• Avstängning av korridorbelysning på nätter ca 1 kW Förslag på åtgärder för Vålbergsskolan:• Konvertering från golvvärme till radiatorsystem ca 5 kW• Avstängning av frekvensstyrning då ventilationen inte är igång 7,5 kW Om föreslagna åtgärder genomförs kan elbasnivån sänkas till 1,2 W/m2 för Frödingskolan och till 2,0 W/m2 för Vålbergsskolan. För den sistnämnda är detta nästan en halvering av den ursprungliga elbasnivån. / The intention of this final thesis has been to find out why some schools in the municipality of Karlstad (Karlstads Kommun), uses different levels of electric power during evenings, weekends and nights. The differences can vary significantly. Because of this, a new concept, called the electricity base level has been defined. The electric base level is the power used during periods of time when there is no activity in the building. After a ranking of the electricity base level made with a self developed excel-model, for an assortment of 15 schools in Karlstads kommun, two of them were selected for further investigation. One school with low electricity base level and one with high electricity base level were selected. Frödingskolan was the school with the lowest electricity base level and was therefore chosen to serve as a reference-building. The other school is Vålbergsskolan and was chosen though it had one of the highest electricity base levels in the ranking. Common for both schools is that there is no electric heating in either building. Furthermore, no major seasonal variation in the school’s electricity consumptions was found. For Frödingskolan an electricity base level at 2.0 W/m2 (0.19 W/ft2) was measured. For Vålbergsskolan the electricity base level was 4.55 W/m2 (0.42 W/ft2). That is almost twice as high as for the first school. Through field studies and extensive measurements, the electricity usage in the two schools was identified. From the obtained results, several measures to reduce the electricity baseline have been developed. This has been done for both of the schools even though Frödingskolan had a low electricity base level from the beginning. It was to be found that even there a lowering of the electricity base level was possible. Proposed measures for Frödingskolan:• Policy to turn off computers after working-hours, approx. 1 kW.• Turning the corridor lights of at night, approx. 1 kW. Proposed measures for Vålbergsskolan:• Conversion from a radiant floor to a radiator system, approx. 5 kW.• Turn the frequency drivers off when no ventilation are running, approx 7.5 kW If the proposed measures are implemented, the electricity base level can be lowered to 1.2 W/m2 (0.12 W/ft2) for Frödingskolan, and 2.0 W/m2 (0.19 W/ft2) for Vålbergsskolan. For the latter, this is almost the half off the current electricity base level
|
Page generated in 0.0431 seconds