• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 3
  • Tagged with
  • 9
  • 6
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Utvärdering av Vissberga lakvattenbehandling / Evaluation of a leachate water treatment plant in Vissberga

Sohlman, Linda January 2010 (has links)
In connection with the admittance of the EC-directive (99/31/EC) in Swedish politic, through the constitution of waste depositing (2001:512) at year 2001, the rules about management the landfills and leachates tightened. At the landfill Vissberga in the municipality of Hallsberg, a leachate treatment plant was constructed just a year thereafter. This treatment plant consisted of an aerated pond with a following land treatment and a willow cultivation to replace the land treatment during the summer. In this case the parameters, which were estimated as the most important to reduce, were iron and nitrogen. The iron would react with the oxygen-rich water in the aerated pond and precipitate to ferric-hydroxide and than settle in a calm zone of the pond. The rest of it would be reduced by filtration in the land treatment. The elimination of nitrogen would happened by two biological processes. The first one was intended to be in the aerated pond, where ammonium ions would oxidise to nitrate by the process called nitrification. The established nitrate would then be transformed to nitrogen gas by a denitrification in the land treatment and be emitted to the air. Unfortunately the reduction has not been desirable, why the main objective of this thesis is to quantify the problem and identify the limitations of the plant by describing the processes involved and find out which factors that affects them, in particular the impact of the temperature. This was executed by a literature study about the processes and by studying results from analysis that were obtained both from earlier samples and from samples which were done during this thesis. At the end it appears that the plant was overloaded and that this probably depends on incorrect estimates of the leachate water flow, done during the dimensioning of the plant. Due to the high flow the ferric-hydroxide can’t be settled and the nitrifyers don’t have enough time to reduce the nitrate. One part of the objective was to found out in which degradation phase the landfill are for the moment, to see what changes is to expect in the combination of the leachate water in the future. However, it was difficult to say with certainty, due to the circumstances that the landfill currently is in the methane phase and the knowledge of the next phase, the humic phase, is very limited because very few landfills has now days reached this phase. The phase determination was made by comparisons between composition of the leachate water of Vissberga and leachate water from the literature. An interview study was also done during this thesis, where people from the Counties Agency in the county of Örebro and Västmanland, the municipality of Uppsala and the Environmental Protection Agency were attended. The question was: Which new requirements that might be claimed at leachate water treatment in a foreseeable future?
2

Metoder för aktivitetstest av anammox och ammoniakoxiderande bakterier på bärarmaterial / Methods for Activity Tests of Anammox and Ammonia Oxidizing Bacteria on Carrier Material

Gustafsson, Ida January 2013 (has links)
I och med övergödningsproblematiken i Östersjön och Sveriges åtaganden i samband med Baltic Sea Action Plan kommer det i framtiden ställas högre krav på rening av kväve från de större avloppsreningsverken i Sverige. Anammox är processen där ammonium oxideras till kvävgas med nitrit som elektonacceptor. Anammox har under den senare tiden implementerats för rejektvattenbehandling i avloppsreningsverk runt om i världen.  När anammox används för att rena ammonium krävs att ca hälften av inkommande ammonium oxideras till nitrit genom nitritation. Detta steg utförs av ammoniakoxiderande bakterier (AOB) vilka kräver en aerob miljö. Den kombinerade processen med anammox och nitritation kallas deammonifikation. På Sjölunda avloppsreningsverk i Malmö har en pilotstudie, i sammarbete med VA-teknik på Lunds Tekniska Högskola, startats för att undersöka potentialen i att implementera deammonifikation i huvudströmmen på reningsverket. Detta examensarbete har syftat till att utarbeta metoder för aktivitetstest av anammox och AOB på bärarmaterial från pilotanläggningen. Med de utarbetade metoderna studerades sedan anammoxbakteriernas aktivitet vid förändrad temperatur. Eftersom anammox producerar kvävgas kunde en metod som baseras på tryckmätning utarbetas för att bestämma anammoxaktiviteten. Metoden visade sig vara tidseffektiv och enkel att utföra. I examensarbetet framkom resultat som visar på att anammox­aktiviteten är beroende av startkoncentrationen av nitrit vid startkoncentrationer under 75 milligram kväve per liter (mg N/l). Beroendet följer av diffusionsbegränsningar i biofilmen vid lägre koncentrationer. Vid startkoncentrationer i intervallet 75-150 mg N/l var aktiviteten oberoende av startkoncentrationen. Vid koncentrationer över 150 mg N/l konstaterades en aktivitetsminskning som troligtvis beror på nitritinhibering. Metoden som arbetades fram för aktivitetstest av AOB baserades på att mäta syrerespirationen innan och efter tillsats av ammonium i en alternerande syresatt reaktor. I metoden skulle en inhibitor för nitritoxiderande bakterier, NaClO3, tillsättas vid slutet av försöket för att säkerställa att dessa bakterier inte konsumerar syre och därmed påverkar resultatet. Vid tillsats av inhibitorn uppstod en orimligt stor aktivitetsförlust som tyder på att denna även inhiberar AOB.  Anammoxaktivitetens temperaturberoende analyserades genom aktivitetsmätning vid fyra temperaturer, i intervallet 11,1-24,9 °C. Försöken visade att förhållandet var exponentiellt och att vid en temperatursänkning från 24,9 °C till 11,1 °C förloras 93 % av aktiviteten. / Given the problem with eutrophication in the Baltic Sea and Sweden's obligations in the Baltic Sea Action Plan, a higher requirement on the removal of nitrogen from the major wastewater treatment plants is expected to be set in the future. Anammox is the process where ammonium is oxidized to nitrogen gas with nitrite as electron acceptor. Anammox has been implemented for treatment of the sludge liquor in wastewater treatment plants around the world. When anammox is used to reduce ammonium, the process requires about half the incoming ammonium to be oxidized into nitrite. This is conducted by ammonia oxidizing bacteria (AOB) that require an aerobic environment. The combined process with anammox and nitritation is called deammonification. A pilot study is taking place at Sjölunda Wastewater Treatment Plant in Malmö in collaboration with Water and Environmental Engineering, Department of Chemical Engineering, Lund University. The aim of the pilot study is to explore the potential of implementing deammonification in the main stream at the wastewater treatment plant. The aim of this Master Theisis is to develop methods for activity tests of Anammox and AOB on carrier material. The elaborated methods were then supposed to be used to study the change in activity with decreasing temperature.  Since anammox produces nitrogen gas a method based on pressure measurements was developed to determine the anammox activity. The results in this thesis showed that the anammox activity was dependent of the initial concentration of nitrite at concentrations below 75 mg N / L. This dependence is a result of the limitations of the diffusion in the biofilm at low concentrations. When the initial concentration of nitrite was within the range of 75 to 150 mg N / L the activity was independent of the initial concentration. At concentrations above 150 mg N / L there was a decrease in activity which probably occurred as a result of nitrite inhibition. To determine the activity of AOB a method based on the oxygen consumption rate was developed. The aeration switched between being turned on and off every five minutes and after some rounds of aereation, ammonium was added. The AOB activity was determined by calculating the difference between the oxygen consumption before and after the addition of ammonium. To ensure that nitrite-oxidizing bacteria (NOB) were not consuming any oxygen, NaClO3 was added at the end of the experiment. The resulting decrease in activity was too excessive to only represent the activity loss from only NOB which may suggest that NaClO3 also inhibits AOB. The temperature dependence of anammox activity was analyzed in activity tests at four temperatures in the range of 11.1 to 24.0°C. The experiments concluded that the relationship was exponential and by a drop in temperature from 24.9 ° C to 11.1 °C 93% of the activity was lost.
3

Elnätets temperaturkänslighet : En undersökning av hur utomhustemperaturens variationerpåverkar effektbehovet i Umeå Energi Elnäts elnät.

Torstensson, Martin January 2021 (has links)
För att vara väl förberedd inför eventuella framtida kapacitetsutmaningar i elnätet ville Umeå Energi Elnät fåen bättre bild på vad variationerna hos energiförbrukningen beror på. I detta examensarbete var målet att undersöka sambandet mellan elnätets effektbehov och utomhustemperaturen samt att ta fram en modell av elnätets effektbehov. För att få en tillräckligt bra modell behövdes fler faktorer som påverkar effektbehovet användas. I modellen som arbetet resulterade i användes förutom utomhustemperaturen även månad, veckodag och tid på dygnet som variabler för att bättre kunna förutsede variationer som finns hos energiförbrukningen. Under arbetets gång upptäcktes ytterligare två faktorer som senare blev en del av modellen på grund av att de hadeen stor påverkan på resultatet. Dessa faktorer var dels ettantal större energiförbrukare, dels en del elproduktioninom Umeå Energi Elnäts elnät.Metoden som användes för att utföra analyserna somkrävdes var linjär regressionsanalys. Det är en statistiskanalysmetod som använder förhållanden mellan olika variabler för att skapa den räta linje som bäst visar sambandet. Detta görs genom att hitta den linje där kvadraten av mätvärdenas avvikelse från regressionslinjen ärminsta möjliga. Till prediktionsmodellen användes multipel linjär regressionsanalys som har samma tillvägagångsätt men med fler variabler.Då utomhustemperaturens påverkan på effektbehovetinte är helt linjärt utan varierar beroende på hur kallt eller varmt det är samt att även de andra faktorernas påverkan varierade gav den multipla regressionsanalysendet bästa resultatet i form av en prediktionsmodell somförklarade ungefär 80% av variationerna hos effektbehovet. / To be well prepared for the future challenges with the capacity in power grid, Umeå Energi Elnät would like to have a better understanding of the variations in energyconsumption and the reasons why it appears. In this thesis, the aim was to investigate the relations between the outside temperature and the energy demands and createa model to explain the power requirements in the grid.To achieve an appropriate model several variables thathave an impact on the energy consumption need to beused. In the end version of the model, the main variableswere outdoor temperature, month, weekday, and time ofday to predict the variations in energy consumption.Along the work two more factors were discovered thathad a large effect on the results. To make the model evenmore accurate these factors, several energy producers,and some larger consumers in Umeå Energi Elnät powergrid need to be included.To accomplish the investigations liner regression analysis was used, which is a statistical analysis method usingthe relationship between different variables creating astraight line. This is done by finding by finding the straight line there the square of the of the deviation of themeasured values from the regression line is the smallestpossible. To make the prediction model multiple regression analysis was used. It has the same approach butwith more than one variable.Since the outdoor temperature did not impact the energyconsumption completely linear but vary, and becausethere are some other factors that have large impact, multiple regression analysis gave the best prediction model.It explained 80% of the variation in power demand
4

Paleomagnetic and Thermomagnetic Studies on Rock Samples from COSC - 1 Drilling Project / Paleomagnetiska och termomagnetiska studier av stenprover från COSC - 1   djupborrningen

Li, Wanyi January 2022 (has links)
The COSC-1 borehole located in the Lower Seve nappe of the Central Scandinavian Caledonides is intended to study the tectonic evolution of the Paleozoic orogen. The drilling project reached a depth of 2495.8m and obtained samples from different lithologal units of mica schist, amphibolite, gneiss, and mylonitic gneisses.     To test if the samples are suitable for paleomagnetism, laboratory measurements of natural remanent magnetism are performed on sub-samples of the COSC-1 drill core in the paleomagnetic laboratory with alternating field demagnetization, IRM acquisition as well as the temperature dependence of susceptibility measurements. Important properties of the samples such as coercivity, Curie temperature, inclination, and declination are determined with the measurements.     Most of the samples carry a remanent magnetization that can be readily demagnetized with alternating field demagnetization up to 100 mT. Some of the samples may be suitable for paleomagnetism, with the major ferromagnetic mineral compositions of magnetite, hematite, and FeTi oxides. However, low coercivities and median destructive fields suggest that the magnetite-bearing samples will be prone to remagnetization, making them more challenging to use in terms of retrieving a primary magnetization originating from the Caledonian orogeny. The thermomagnetic results of some samples reflect the metamorphic conditions experienced by the rocks and the mineral assemblage changed irreversibly during step-wise heating experiments. These results can possibly be used as an indicator for the metamorphic temperature experienced by the different lithologal units. Although further measurements are needed to get a clearer understanding of the suitability of the COSC-1 sample for paleomagnetic reconstructions (including thermal demagnetization experiments), this thesis indicates that the COSC-1 rocks contain interesting paleo- and rock magnetic features that are worth further study.
5

SLAGGBETONG OCH DESS HÅLLFASTHETUTVECKLING VID OLIKA HÄRDNINGSTEMPERATURER . / SLAG-CONCRETE AND THE INFLUENCE ON STRENGHT DEVELOPMENT AT VARIOUS CURING TEMPERATURE .

Andersson, Oscar, Stenberg, Johan January 2022 (has links)
Bygg- och infrastruktursektorn präglas av betongkonstruktioner av diverse utformning där koldioxidutsläpp är ett känt problem hos betongindustrin. Bindemedlet cement utgör den största delen av koldioxidutsläppen, därav forskas det på alternativa material till cement där ett av de materialen är slagg. Att använda betong med höga ersättningsandelar av slagg är något som är möjligt under förutsättningar att forskning bedrivs, för att kunna säkerställa god funktion enligt standarder. Examensarbetet ämnar undersöka temperaturens inverkan vid härdningsprocessen. Examensarbetet möjliggjordes med hjälp av en litteraturstudie, dialog med Oskar Linderoth på Swerock samt via gjutning av betongkuber med vattenhärdning i laborationsmiljö. Hållfasthet testades med hydraulikpress på Örebro Universitet. De betongsammansättningar som gjöts hade 40% respektive 60% slagginblandning. Betongkuberna härdades i vattenbad i 20°C i inomhusklimat samt i 40°C i ett värmeskåp. Slutligen tryckprovades respektive betongsammansättning efter 3, 7 och 28 dygn. Totalt omfattade härdning och provtryckning 12 kuber.  Resultaten visar att en högre härdningstemperatur medför en högre tryckhållfasthet mellan 3 och 28 dygn både vid 40% respektive 60% slagginblandning. I betongen med 40% slagginblandning ger den högre härdningstemperaturen initialt en högre hållfasthet, men den betongen med lägre härdningstemperatur sammanfaller med den högre efter 28 dygn. Den betongen med 60% slagginblandning har en mer parallell hållfasthetsutveckling mellan den lägre respektive högre härdningstemperaturen efter 3 och 28 dygn. Den högre härdningstemperaturen medför som tidigare en högre hållfasthet än den lägre härdningstemperaturen. Slutligen tyder resultaten på att en högre slagginblandning generellt medför en något lägre initial hållfasthet tidigt i härdningsprocessen, men att den kring 28 dygn har liknande eller högre hållfasthet än den betongen med mindre slagg. Slutsatsen är att Swerocks produkter visar tendenser till att varierande härdningstemperatur har en påverkan på betong med varierande andelar slagg. Det skulle dock behövas mer gjutningar för att få ett säkrare resultat och bredare spridning för att säkerställa att liknande resultat uppnås med fler kuber. / The construction and infrastructure sector consists of a lot of concrete structures where carbon dioxide emissions are a known problem in the concrete industry. The binder cement makes up the largest part of the carbon dioxide emissions, hence research is being done on alternative materials to cement and one of those materials is slag. Using concrete with high replacement proportions of slag is something that is possible under conditions that research is conducted, to ensure good function according to requirements. The thesis intends to investigate the effect of temperature in the curing process. The degree project was made possible with the help of a literature study, dialogue with Oskar Linderoth at Swerock and via casting of concrete cubes with water curing in a laboratory environment. Strength development was tested at Örebro University with a hydraulic press. The concrete compositions that were cast had 40% and 60% slag mixture, respectively. The concrete cubes were hardened in a water bath at 20°C in an indoor climate and at 40°C in a heating cabinet. Finally, the respective concrete composition was tested for strenght after 3, 7 and 28 days. In total, curing and casting comprised 12 cubes.  The results show that a higher curing temperature results in a higher compressive strength between 3 and 28 days both at 40% and 60% slag mixture, respectively. In the concrete with 40% slag mixture, the higher curing temperature initially gives a higher strength, but the concrete with a lower curing temperature coincides with the higher one after 28 days. The concrete with 60% slag mixture has a more parallel strength development between the lower and higher curing temperature, respectively, after 3 and 28 days. As before, the higher curing temperature results in a higher strength than the lower curing temperature. Finally, the results indicate that a higher slag mixture generally results in a slightly lower initial strength early in the hardening process, but that it is around 28 days higher than the concrete with less slag with the help of a higher curing temperature. The conclusion is that Swerock's products show tendencies that varying curing temperature influences concrete with varying proportions of slag. However, more castings would be needed to obtain a safer result and a wider spread to ensure that similar results are achieved with more cubes.
6

Performance evaluation of ground source heat pump heating systems in Stockholm

BÖRJESSON, MARCUS January 2020 (has links)
GSHP systems are common in Sweden but there are few evaluations quantifying the performance of the systems and highlighting problem that occurs during operations. The research project Annex 52 Long-term performance measurement of GSHP systems serving commercial, institutional and multifamily building part of IEA HPT TCP proves the need to systematically be able to evaluate GSHP systems. This thesis aims to expand the knowledge of how to evaluate GSHP systems and provide case studies for Annex 52. Three residential ground source heating systems used for heating has been evaluated and analyzed in this study. The evaluation has consisted of three parts. The first part analyzes the operation and stability of the GSHP systems. The second part consist of a detailed study of the performance of the GSHP systems. The seasonal performance factor has been calculated for different system boundaries based on the work done by SEPEMO. In addition, a method on how to evaluate the efficiency of the heat pumps based on the two temperature levels, source side temperature and the heat sink temperature, that the heat pump is operating at throughout a year has been developed within this thesis. This has included a method on how to normalize the temperatures based on the operation of the heat pump in order to quantify one temperature for each the two temperature levels. The third part consist of a comparison of the mean secondary fluid temperature between the calculated temperature using the software EED and the measured temperatures. This includes a comparison evaluation and sensitivity analysis on input parameters during the design of the borehole heat exchanger fields. This study has expanded the available reference cases of GSHP systems in Sweden. It also can be used as a guideline for those who will evaluate future GSHP systems. Designers of GSHP system will also benefit from the recommendations listed in this thesis regarding instrumentation and possible problems that may occur. The results show that the evaluation successfully managed to quantify the performance and operational issues that have occurred for each system. The method developed in this study was able to quantify the operation of the different systems based on the temperature levels and can be used for future GSHP evaluations of similar system type. / Bergvärmesystem är vanligt förekommande i Sverige men trots detta finns det få studier där prestandan har utvärderats och de vanligt förekommande problemen under drift har belysts. Forskningsprojektet Annex 52 Annex 52 Long-term performance measurement of GSHP systems serving commercial, institutional and multi-family building som är en del av IEA HPT TCP visar på behovet av att systematisk utvärdera bergvärmesystem. Detta examensarbete syftar till att utveckla och bidra till kunskap om hur bergvärmesystem kan utvärderas och att bidra med exempelstudier till Annex 52. Inom detta examensarbete har tre bergvärmesystem som betjänar flerbostadshus utvärderats och analyserats. Utvärderingen bestod av tre analyser. I den första analyserades driften av bergvärmesystemen och hur stabilt systemet har varit historiskt. Detta följdes av en detaljerad analys av olika nyckeltal för bergvärmesystemen. Årsverkningsgraden har beräknats för olika gränsdragningar vilka baseras på det tidigare arbetet utfört av SEPEMO. Inom detta examensarbete har även en metod tagits fram för att utvärdera verkningsgraderna för en värmepump baserat på de två temperaturnivåerna, köldbärarsidan och värmebärarsidan, som värmepumpen arbetar med under ett år. Till detta har en metod tagits fram om hur temperaturen kan normaliserats baserat på driften av värmepumparna för att kvantifiera en temperatur vardera för de två temperaturnivåerna. I den tredje utvärderingen jämfördes den beräknade medelfluidtemperaturen av köldbäraren i borrhålen med den uppmätta temperaturen. Till detta utfördes en känslighetsanalys av hur indata av dessa beräkningar påverkar resultaten.
7

Analys av elbasnivå för Vålbergsskolan, Karlstads Kommun : Kartläggning av elanvändning nattetid samt undersökning av energieffektiviserande åtgärder. / Analysis of the electricity base level for Vålbergsskolan, Karlstads Kommun : Identification of electricity usage during the night and investigation of energy-efficiency measures

Andersson, Erik January 2011 (has links)
Examensarbetet har gått ut på att ta reda på varför en del skolor i Karlstads kommun, använder olika mycket el under kvällar, helger och nätter. Skillnaderna är stora och på grund av det har ett nytt begrepp, kallat elbasnivå, definierats. I princip är elbasnivån den effekt som används under de tider som lokalerna inte nyttjas. Efter genomförd rangordning av elbasnivån med hjälp av en egenutvecklad excelkalkyl, för ett urval på 15 skolor i Karlstads kommun, valdes två av dessa ut för vidare utredning. En skola med låg elbasnivå och en skola med hög elbasnivå valdes. Frödingskolan är den skola som har lägst elbasnivå och valdes att fungera som en referensbyggnad. Den andra skolan är Vålbergsskolan och den valdes då den hade en av de högsta elbasnivåerna i rangordningen. Gemensamt för båda skolorna är att det inte förekommer någon elvärme i fastigheterna. Dessutom finns ingen större årstidsvariation i skolornas elförbrukning. För Frödingskolan uppmättes en elbasnivå på 2,0 W/m2 och för Vålbergskolan 4,6 W/m2, alltså mer än dubbelt så hög för den sistnämnda. Genom studiebesök och omfattande mätningar har elanvändningen i de båda skolorna kunnat kartläggas. Av de resultat som fåtts har olika åtgärder för att sänka elbasnivån tagits fram. Detta har gjorts för båda skolorna även om Frödingskolan hade en låg elbasnivå från början. Det visade sig att även där fanns det åtgärder som kan sänka elbasnivån. Förslag på åtgärder för Frödingskolan:• Policy för avstängning av datorer efter arbetstid ca 1 kW• Avstängning av korridorbelysning på nätter ca 1 kW Förslag på åtgärder för Vålbergsskolan:• Konvertering från golvvärme till radiatorsystem ca 5 kW• Avstängning av frekvensstyrning då ventilationen inte är igång 7,5 kW Om föreslagna åtgärder genomförs kan elbasnivån sänkas till 1,2 W/m2 för Frödingskolan och till 2,0 W/m2 för Vålbergsskolan. För den sistnämnda är detta nästan en halvering av den ursprungliga elbasnivån. / The intention of this final thesis has been to find out why some schools in the municipality of Karlstad (Karlstads Kommun), uses different levels of electric power during evenings, weekends and nights. The differences can vary significantly. Because of this, a new concept, called the electricity base level has been defined. The electric base level is the power used during periods of time when there is no activity in the building. After a ranking of the electricity base level made with a self developed excel-model, for an assortment of 15 schools in Karlstads kommun, two of them were selected for further investigation. One school with low electricity base level and one with high electricity base level were selected. Frödingskolan was the school with the lowest electricity base level and was therefore chosen to serve as a reference-building. The other school is Vålbergsskolan and was chosen though it had one of the highest electricity base levels in the ranking. Common for both schools is that there is no electric heating in either building. Furthermore, no major seasonal variation in the school’s electricity consumptions was found. For Frödingskolan an electricity base level at 2.0 W/m2 (0.19 W/ft2) was measured. For Vålbergsskolan the electricity base level was 4.55 W/m2 (0.42 W/ft2). That is almost twice as high as for the first school. Through field studies and extensive measurements, the electricity usage in the two schools was identified. From the obtained results, several measures to reduce the electricity baseline have been developed. This has been done for both of the schools even though Frödingskolan had a low electricity base level from the beginning. It was to be found that even there a lowering of the electricity base level was possible. Proposed measures for Frödingskolan:• Policy to turn off computers after working-hours, approx. 1 kW.• Turning the corridor lights of at night, approx. 1 kW. Proposed measures for Vålbergsskolan:• Conversion from a radiant floor to a radiator system, approx. 5 kW.• Turn the frequency drivers off when no ventilation are running, approx 7.5 kW If the proposed measures are implemented, the electricity base level can be lowered to 1.2 W/m2 (0.12 W/ft2) for Frödingskolan, and 2.0 W/m2 (0.19 W/ft2) for Vålbergsskolan. For the latter, this is almost the half off the current electricity base level
8

Temperatur- och flödesberoende beteende i anslutning till lek hos harr (Thymallus thymallus) i Indalsälven / Temperature- and flow dependent behaviour of grayling (Thymallus thymallus) in Indalsälven during spawning season

Sjöström, Daniel January 2023 (has links)
Vattenkraftens påverkan på rinnande vatten är välbeskriven i litteraturen. Med ökat intresse för vindkraft och andra energislag med begränsad klimatpåverkan, ökar även behovet av reglerkraft. Effekten av korttidsreglerad vattenkraft på ekosystem är ett aktuellt ämne med kunskapsluckor i stort behov av fler studier. Indalsälven passerar Järkvissle kraftverk några mil norr om Sundsvall. Den lokala harrpopulationen har minskat kraftigt och misstankar finns om kopplingar till korttidsregleringen i Järkvissle kraftverk. Vid förvaltning av ekosystem och djuren i dem är kunskapen om interaktioner och beteenden bland det viktigaste att etablera. Detta för att kunna avgöra om artens beteende påverkas av korttidsreglering. Bristande kunskap om lokala lekbeteenden innebar således att harren nedan Järkvissle kraftverk studerades inför förväntad lekperiod. Studien baserades på två antaganden 1) harr förflyttar sig uppströms mot grundområden, lämpade för lek, när vattentemperaturen ökar. 2) harr är mer aktiv när flödesvariationen är hög, eftersom lekplatsernas beskaffenhet påverkas av flödesförhållanden. Harr (n = 20) från sträckan nedan Järkvissle kraftverk märktes med radiosändare, för att studera rörelsemönster och beteenden i anslutning till lek under perioden 28 april till 29 maj 2022. Vid 24 handpejlingstillfällen registrerades de märkta individernas position och djup. En Multipel linjär regression med bakåtvänd eliminering gav tre signifikanta resultat. Det observerades en ökad aktivitet i form av euklidisk förflyttning vid höga flöden motsvarande en förflyttning om 1,0 m (± 1 m) för varje 1,0 m3 s-1 ökat flöde. Det observerades även ett temperaturberoende val av ståndplats där en ökning om 1,0 ºC resulterade i en förflyttning till en ståndplats som var 0,21 ± 0,03 m grundare, på ett avstånd som var 65,2 ± 12,5 m längre bort från dammen. Studien bör kompletteras med kartläggning av optimala värden för flödesförändring som gynnar harr, samt om det finns andra variabler som bättre kan förutse tidpunkt och plats för lek. Om avsikten är att stoppa minskandet av harrbeståndet i Järkvissle, bör Järkvissle kraftstation övervaka vattentemperatur och anpassa sin flödesregim. Detta för mjukare övergångar mellan högt och lågt flöde samt att flödet hålls stabilt under lek med fyra extra veckors utrymme för inkubering. / The effect of hydroelectric powerplants (HEP) on waterways is extensive and has been well documented in the literature. But with an increased interest in wind power and other green alternatives, a higher demand for regulated hydroelectric power has emerged, so as not to put stress on the electric grid. Hydropeaking and its effect on ecosystems are a hot topic with gaps in knowledge calling for more research. Indalsälven runs through Järkvissle HEP a few miles north of Sundsvall. The local grayling population has seen a large decline and there are suspicions of a connection to the hydropeaking at Järkvissle HEP. When managing ecosystems and the animals within them it is vital to establish a firm understanding of interactions and behaviour. This can be used to determine the effect of hydropeaking on the behaviours of grayling. A lack in knowledge of local spawning behaviour thus led to a study of the grayling2population below Järkvissle HEP leading up to the expected spawning period. The study was based around two assumptions: 1) grayling move upstream towards shallower areas suitable for spawning as the temperature in the water rises, and 2) grayling are more active when the variation in flow is high, because the number of suitable spawning grounds are limited by flow. Graylings (n = 20) in the area below the Järkvissle HEP were tagged with radio transmitters, to study the movement and behaviour exhibited before the expected spawning period between April 28th and May 29th, 2022. On 24 occasions hand tracking was performed and position and depth of the marked individuals were recorded. Through a multiple linear regression with backwards stepwise elimination three significant results were found. There was an observed increase in activity in the form of Euclidean movement represented by a 1,0 m (± 1 m) movement for every 1,0 m3 s-1 of increased flow. We also observed a temperature dependency when it came to habitat choice, where an increase of 1,0 ºC in water temperature resulted in a movement to an area 0,21 ± 0,03 m shallower, at a distance that was 65,2 ± 12,5 m further from the dam. The findings of this study should be expanded upon with further research into optimal values for flow variation that best suit grayling, and additionally explore whether there are other variables to better predict time and place for spawning. If the intention is to stop the decline of the grayling population, Järkvissle HEP should monitor the water temperature and adapt their flow regime to make softer transitions between high and low flow and keeping the flow at a stable interval during spawning and an additional four weeks to leave room for incubation.
9

Phonons in 1-D Graphene Nanoribbons Probed with Raman Spectroscopy : Unraveling Fundamental Properties in 9-atom-wide Graphene Nanoribbons

Victor Labordet Alvarez, Angel January 2023 (has links)
This report employs advanced Raman spectroscopy techniques to investigate the fundamental properties of 9-AGNRs comprehensively. It is divided into two main sections addressing distinct aspects of 9-AGNR behavior. In the first section, Polarization Raman spectroscopy (PRS) probes phonon mode symmetries in 9-AGNRs. Our analysis reveals deviations from predicted symmetries, suggesting the presence of lattice defects. We also investigate specific phonon modes (G, D, and RBLM), providing insights into lattice integrity. The second section employs temperature-dependent Raman spectroscopy to explore the thermal properties of 9-AGNRs. This dynamic analysis quantifies vibrational mode responsiveness to temperature variations using the Grüneisen parameter (χ). Comparisons across various carbon-based materials uncover distinct sensitivities and stabilities. This research advances our understanding of 9-AGNR properties, with implications for nanomaterial science and potential applications. / Denna rapport använder avancerade Raman spektroskopitekniker för att på ett omfattande sätt undersöka de grundläggande egenskaperna hos 9-AGNRs. Den är uppdelad i två huvudsektioner som tar upp distinkta aspekter av 9-AGNR beteende. I det första avsnittet sonderar Polarisation Raman spektroskopi (PRS) fononlägessymmetrier i 9-AGNRs. Vår analys avslöjar avvikelser från förutsagda symmetrier, vilket tyder på närvaron av gitterdefekter. Vi undersöker också specifika fononlägen (G, D och RBLM), vilket ger insikter om gitterintegritet. Den andra sektionen använder temperaturberoende Raman-spektroskopi för att utforska de termiska egenskaperna hos 9-AGNRs. Denna dynamiska analys kvantifierar vibrationslägets känslighet för temperaturvariationer med hjälp av Grüneisen-parametern (χ). Jämförelser mellan olika kolbaserade material avslöjar distinkta känsligheter och stabiliteter. Denna forskning främjar vår förståelse av 9-AGNR-egenskaper, med implikationer för nanomaterialvetenskap och potentiella tillämpningar.

Page generated in 0.4619 seconds