• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 2
  • 2
  • Tagged with
  • 7
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Värme från gruvvatten : En undersökning av olika metoder för att kunna hämta värme ur vattnet som pumpas upp ur gruvorna / HEAT FROM MINE WATER : An investigation of different methods to be able to retrieve heat from the water that is pumped up from the mines

Mathilda, Glas January 2023 (has links)
Boliden Mineral AB - Boliden Mines is a company that carries out continuous improvement work in the energy and environmental area. During this degree project, the possibility of making use of waste heat from the mine water that is pumped out of the Renström mine was evaluated. The possibility of making use of the heat from the mine water is interesting as the water that is pumped up maintains a stable temperature between +8 degrees to +20 degrees. This provides a suitable heat source for heat pumps by extracting the heat using heat exchangers or collectors. The purpose of this thesis has been to investigate which type of solution between collectors and heat exchangers is technically and economically most advantageous. The cases reviewed are to either invest in components for the existing heat pump, which is located next to the collection basin, in the old treatment plant, or to invest in a new facility in connection with the fire dam. Reviews to determine alternative collectors and heat exchangers were carried out on a theoretical basis. The review was based on the fact that collectors and heat exchangers must be durable, easy to disassemble and easy to maintain. Through economic analyzes and discussion with various companies and suppliers, three different collectors and three different heat exchangers respectively were determined as possible solutions. Conclusions were extracted from these components for the various cases. The conclusion that can be drawn for the existing case of the existing heat pump located adjacent to the collection pond, the old treatment plant, is that an installation of two Geek kooil collectors is the most economically beneficial investment. The company also chose to invest in this option.For the case of a new facility in connection with the fire dam, the result is presented depending on the investment in the number of heat pumps, where the payback times vary between the different investment options. The payback time of the collectors and heat exchangers varies between 3 to 8 years depending on the number of heat pumps or collectors.Conclusion given from both the existing case and the case of a new plant gave that from the point of view of the collectors, the Geek kooil collector was the better option, both for the existing heat pump and for a new installation of one, two or three heat pumps. A Geek kooil collector gave an investment cost per kW between SEK 3813 and 2647/kW. For the heat exchangers, the plate heat exchanger from Alfa laval was determined to be the better option for a new installation of both one, two or three heat pumps. The plate heat exchanger from Alfa laval gave an investment per kW of SEK 360/kW, which is lower than the comparative alternatives.
2

Entwicklung von GaAs-basierten Heterostruktur-Bipolartransistoren (HBTs) für Mikrowellen-Leistungszellen

Maassdorf, Andre January 2007 (has links)
Zugl.: Berlin, Techn. Univ., Diss., 2007
3

High Area Capacity Lithium-Sulfur Full-cell Battery with Prelitiathed Silicon Nanowire-Carbon Anodes for Long Cycling Stability

Krause, Andreas, Dörfler, Susanne, Piwko, Markus, Wisser, Florian M., Jaumann, Tony, Ahrens, Eike, Giebeler, Lars, Althues, Holger, Schädlich, Stefan, Grothe, Julia, Jeffery, Andrea, Grube, Matthias, Brückner, Jan, Martin, Jan, Eckert, Jürgen, Kaskel, Stefan, Mikolajick, Thomas, Weber, Walter M. 25 January 2017 (has links) (PDF)
We show full Li/S cells with the use of balanced and high capacity electrodes to address high power electro-mobile applications. The anode is made of an assembly comprising of silicon nanowires as active material densely and conformally grown on a 3D carbon mesh as a light-weight current collector, offering extremely high areal capacity for reversible Li storage of up to 9 mAh/cm(2). The dense growth is guaranteed by a versatile Au precursor developed for homogenous Au layer deposition on 3D substrates. In contrast to metallic Li, the presented system exhibits superior characteristics as an anode in Li/S batteries such as safe operation, long cycle life and easy handling. These anodes are combined with high area density S/C composite cathodes into a Li/S full-cell with an ether- and lithium triflate-based electrolyte for high ionic conductivity. The result is a highly cyclable full-cell with an areal capacity of 2.3 mAh/cm(2), a cyclability surpassing 450 cycles and capacity retention of 80% after 150 cycles (capacity loss <0.4% per cycle). A detailed physical and electrochemical investigation of the SiNW Li/S full-cell including in-operando synchrotron X-ray diffraction measurements reveals that the lower degradation is due to a lower self-reduction of polysulfides after continuous charging/discharging.
4

Untersuchungen zur Energiegewinnung mit einem Solardach-Luft-Kollektor / Investigations into the production of energy with a solar roof air heater

Baum, Matthias 15 July 2010 (has links)
No description available.
5

High Area Capacity Lithium-Sulfur Full-cell Battery with Prelitiathed Silicon Nanowire-Carbon Anodes for Long Cycling Stability

Krause, Andreas, Dörfler, Susanne, Piwko, Markus, Wisser, Florian M., Jaumann, Tony, Ahrens, Eike, Giebeler, Lars, Althues, Holger, Schädlich, Stefan, Grothe, Julia, Jeffery, Andrea, Grube, Matthias, Brückner, Jan, Martin, Jan, Eckert, Jürgen, Kaskel, Stefan, Mikolajick, Thomas, Weber, Walter M. 25 January 2017 (has links)
We show full Li/S cells with the use of balanced and high capacity electrodes to address high power electro-mobile applications. The anode is made of an assembly comprising of silicon nanowires as active material densely and conformally grown on a 3D carbon mesh as a light-weight current collector, offering extremely high areal capacity for reversible Li storage of up to 9 mAh/cm(2). The dense growth is guaranteed by a versatile Au precursor developed for homogenous Au layer deposition on 3D substrates. In contrast to metallic Li, the presented system exhibits superior characteristics as an anode in Li/S batteries such as safe operation, long cycle life and easy handling. These anodes are combined with high area density S/C composite cathodes into a Li/S full-cell with an ether- and lithium triflate-based electrolyte for high ionic conductivity. The result is a highly cyclable full-cell with an areal capacity of 2.3 mAh/cm(2), a cyclability surpassing 450 cycles and capacity retention of 80% after 150 cycles (capacity loss <0.4% per cycle). A detailed physical and electrochemical investigation of the SiNW Li/S full-cell including in-operando synchrotron X-ray diffraction measurements reveals that the lower degradation is due to a lower self-reduction of polysulfides after continuous charging/discharging.
6

Performance evaluation of ground source heat pump heating systems in Stockholm

BÖRJESSON, MARCUS January 2020 (has links)
GSHP systems are common in Sweden but there are few evaluations quantifying the performance of the systems and highlighting problem that occurs during operations. The research project Annex 52 Long-term performance measurement of GSHP systems serving commercial, institutional and multifamily building part of IEA HPT TCP proves the need to systematically be able to evaluate GSHP systems. This thesis aims to expand the knowledge of how to evaluate GSHP systems and provide case studies for Annex 52. Three residential ground source heating systems used for heating has been evaluated and analyzed in this study. The evaluation has consisted of three parts. The first part analyzes the operation and stability of the GSHP systems. The second part consist of a detailed study of the performance of the GSHP systems. The seasonal performance factor has been calculated for different system boundaries based on the work done by SEPEMO. In addition, a method on how to evaluate the efficiency of the heat pumps based on the two temperature levels, source side temperature and the heat sink temperature, that the heat pump is operating at throughout a year has been developed within this thesis. This has included a method on how to normalize the temperatures based on the operation of the heat pump in order to quantify one temperature for each the two temperature levels. The third part consist of a comparison of the mean secondary fluid temperature between the calculated temperature using the software EED and the measured temperatures. This includes a comparison evaluation and sensitivity analysis on input parameters during the design of the borehole heat exchanger fields. This study has expanded the available reference cases of GSHP systems in Sweden. It also can be used as a guideline for those who will evaluate future GSHP systems. Designers of GSHP system will also benefit from the recommendations listed in this thesis regarding instrumentation and possible problems that may occur. The results show that the evaluation successfully managed to quantify the performance and operational issues that have occurred for each system. The method developed in this study was able to quantify the operation of the different systems based on the temperature levels and can be used for future GSHP evaluations of similar system type. / Bergvärmesystem är vanligt förekommande i Sverige men trots detta finns det få studier där prestandan har utvärderats och de vanligt förekommande problemen under drift har belysts. Forskningsprojektet Annex 52 Annex 52 Long-term performance measurement of GSHP systems serving commercial, institutional and multi-family building som är en del av IEA HPT TCP visar på behovet av att systematisk utvärdera bergvärmesystem. Detta examensarbete syftar till att utveckla och bidra till kunskap om hur bergvärmesystem kan utvärderas och att bidra med exempelstudier till Annex 52. Inom detta examensarbete har tre bergvärmesystem som betjänar flerbostadshus utvärderats och analyserats. Utvärderingen bestod av tre analyser. I den första analyserades driften av bergvärmesystemen och hur stabilt systemet har varit historiskt. Detta följdes av en detaljerad analys av olika nyckeltal för bergvärmesystemen. Årsverkningsgraden har beräknats för olika gränsdragningar vilka baseras på det tidigare arbetet utfört av SEPEMO. Inom detta examensarbete har även en metod tagits fram för att utvärdera verkningsgraderna för en värmepump baserat på de två temperaturnivåerna, köldbärarsidan och värmebärarsidan, som värmepumpen arbetar med under ett år. Till detta har en metod tagits fram om hur temperaturen kan normaliserats baserat på driften av värmepumparna för att kvantifiera en temperatur vardera för de två temperaturnivåerna. I den tredje utvärderingen jämfördes den beräknade medelfluidtemperaturen av köldbäraren i borrhålen med den uppmätta temperaturen. Till detta utfördes en känslighetsanalys av hur indata av dessa beräkningar påverkar resultaten.
7

Högtempererat borrhålslager för fjärrvärme / High Temperature Borehole Thermal Energy Storage for District Heating

Hallqvist, Karl January 2014 (has links)
The district heating load is seasonally dependent, with a low load during periods of high ambient temperature. Thermal energy storage (TES) has the potential to shift heating loads from winter to summer, thus reducing cost and environmental impact of District Heat production. In this study, a concept of high temperature borehole thermal energy storage (HT-BTES) together with a pellet heating plant for temperature boost, is presented and evaluated by its technical limitations, its ability to supply heat, its function within the district heating system, as well as its environmental impact and economic viability in Gothenburg, Sweden, a city with access to high quantities of waste heat. The concept has proven potentially environmentally friendly and potentially profitable if its design is balanced to achieve a good enough supply temperature from the HT-BTES. The size of the heat storage, the distance between boreholes and low borehole thermal resistance are key parameters to achieve high temperature. Profitability increases if a location with lower temperature demand, as well as risk of future shortage of supply, can be met. Feasibility also increases if existing pellet heating plant and district heating connection can be used and if lower rate of return on investment can be accepted. Access to HT-BTES in the district heating network enables greater flexibility and availability of production of District Heating, thereby facilitating readjustments to different strategies and policies. However, concerns for the durability of feasible borehole heat exchangers (BHE) exist in high temperature application. / Värmebehovet är starkt säsongsberoende, med låg last under perioder av högre omgivningstemperatur och hög last under perioder av lägre omgivningstemperaturer. I Göteborg finns en stor mängd spillvärme tillgängligt för fjärrvärmeproduktion sommartid när behovet av värme är lågt. Tillgång till säsongsvärmelager möjliggör att fjärrvärmeproduktion flyttas från vinterhalvår till sommarhalvår, vilket kan ge såväl lönsamhet som miljönytta. Borrhålsvärmelager är ett förhållandevis billigt sätt att lagra värme, och innebär att berggrunden värms upp under sommaren genom att varmt vatten flödar i borrhål, för att under vinterhalvåret användas genom att låta kallt vatten flöda i borrhålen och värmas upp. I traditionella borrhålsvärmelager används ofta värmepump för att höja värmelagrets urladdade temperatur, men på grund av höga temperaturkrav för fjärrvärme kan kostnaden för värmepump bli hög. I denna rapport föreslås ett system för att klara av att nå höga temperaturer till en lägre kostnad. Systemet består av ett borrhålsvärmelager anpassat för högre temperaturer (HT-BTES) samt pelletspannor för att spetsa lagrets utgående fluid för att nå hög temperatur. Syftet med rapporten är att undersöka potentialen för detta HT-BTES-system med avseende på dess tekniska begränsningar, förmåga till fjärrvärmeleverans, konsekvenser för fjärrvärmesystemet, samt lönsamhet och miljöpåverkan. För att garantera att inlagringen av värme inte är så stor att priset för inlagrad värme ökar väsentligt, utgår inlagringen från hur mycket värme som kyls bort i fjärrvärmenätet sommartid. I verkligheten finns betydligt mer värme tillgänglig till låg kostnad. När HT-BTES-systemet producerar fjärrvärme, ersätts fjärrvärmeproduktion från andra produktionsenheter, förutsatt att HT-BTES-systemets rörliga kostnader är lägre. I Göteborg ersätts främst naturgas från kraftvärme, men också en del flis. Kostnadsbesparingen beror på differensen för total fjärrvärmeproduktionskostnad med och utan HT-BTES-systemet. Undersökningen visar att besparingen är större om HT-BTES-systemet placeras i ett område där det är möjligt att mata ut fjärrvärme med lägre temperatur. Om urladdning från HT-BTES kan ske med hög temperatur ökar också besparingen. Detta sker om lagrets volym ökar, om avståndet mellan borrhål minskar eller om värmeöverföringen mellan det flödande vattnet i borrhålen och berggrunden ökar. Dessa egenskaper för lagret leder också till minskade koldioxidutsläpp. Storleken på besparingen beror dock i hög grad på hur bränslepriser utvecklas i framtiden. Strategiska fördelar med HT-BTES-systemet inkluderar; minskad miljöpåverkan, robust system med lång teknisk livslängd (för delar av HT-BTES-systemet), samt att inlagring av värme kan ske från många olika produktionsenheter. Dessutom kan positiva bieffekter identifieras. Undersökningen visar att HT-BTES-systemet har god potential att ge lönsamhet och minskad miljöpåverkan, och att anläggning och drift av lagret kan ske utan omfattande lokal miljöpåverkan. Det har också visats att de geologiska förutsättningarna för HT-BTES är goda på många platser i Göteborg, även om lokala förhållanden kan skilja sig åt. För att nå lönsamhet för HT-BTES-systemet krävs en avvägning på utformning av lagret för att nå hög urladdad temperatur utan att investeringskostnaden blir för stor. Undersökningen visar att om anslutning av HT-BTES-systemet kan ske mot befintlig anslutningspunkt eller till befintlig värmepanna kan investeringskostnaden minska och därmed lönsamheten öka. Placering av HT-BTES-systemet i områden med risk för överföringsbegränsningar kan också minska behovet av att förstärka fjärrvärmenätet, och således bidra till att minska de kostnader som förstärkning av nätet innebär. Betydelsefulla parametrar för att nå lönsamhet för HT-BTES-system inkluderar dessutom kostnaden för inlagrad värme liksom vilket vinstkrav som kan accepteras. Tillgång till HT-BTES möjliggör ökad nyttjandegrad och flexibilitet för fjärrvärmeproduktionsenheter, och därmed ökad anpassningsmöjlighet till förändrade förutsättningar på värmemarknaden. Dock återstår att visa att komponenter som klarar de höga temperaturkraven kan tillverkas till acceptabel kostnad.

Page generated in 0.0545 seconds