• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeitos do alcoolismo na percepção visual de contraste

CRUZ, Ellen Dias Nicácio da 31 January 2010 (has links)
Made available in DSpace on 2014-06-12T23:00:37Z (GMT). No. of bitstreams: 2 arquivo737_1.pdf: 1257104 bytes, checksum: 9722b502b35842743379a4cc2a4fc9d3 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2010 / O objetivo desta pesquisa foi investigar os efeitos do alcoolismo na percepção visual de contraste, utilizando a função de sensibilidade ao contraste (FSC), como indicador. Oito voluntários foram inclusos no grupo experimental (GE) e nove, no grupo controle (GC). O GE foi caracterizado por apresentar a síndrome de depêndencia ao álcool, média de 46,7 anos de idade, 63% do sexo masculino, média de tempo de consumo de álcool e abstinência de 18 anos e 13,3 anos, respectivamente. Com exceção de um, todos os participantes do GE eram exfumantes e freqüentavam os Alcoólicos Anônimos. Nenhum voluntário apresentou escore no Inventário de Depressão Beck (BDI) acima do ponto de corte (BDI > 20). O GC não apresentou histórico de consumo de álcool ou de outras substâncias, com 56% dos participantes do sexo feminino e média 42,78 anos de idade. Ambos os grupos tinham a acuidade normal ou corrigida e não possuiam outras patologias diagnósticadas que afetassem as funções ópticas. Todos os voluntários foram submetidos ao método psicofísico da escolha forçada com duas alternativas temporais. Neste paradigma, os voluntários tiveram que decidir qual de dois padrões continha o estímulo teste. O outro estímulo era sempre cinza, com a luminância média (42 cd/m²). A escolha correta era selecionar a frequência grade senoidal cartesiana (0,25; 1; 2; 8 cpg), radial (0,25; 1; 2; 8 cpg) ou angular (3; 24; 48 e 96 ciclos/ 360º). Os padrões tinham um diâmetro de 7,25 graus de ângulo visual, a 150 cm de distância da tela. Os resultados mostraram diferenças significantes entre os GE e GC para as frequências espaciais grades cartesianas de 1 e 2 cpg; para as grades radiais de 0,25; 1 e 2 cpg; e para as grades angulares de 48 e 96 ciclos/ 360º (p < 0,05). Em geral, isto indica que o alcoolismo altera a FSC principalmente nas médias frequências espaciais, mesmo depois de um longo período de abstinência
2

Processamento visual de contraste em pacientes com depressão maior

Lacerda, Aline Mendes 26 June 2012 (has links)
O presente estudo teve como objetivo investigar possíveis alterações na percepção visual relacionadas à depressão maior. Para tanto, realizou-se medidas de sensibilidade ao contraste (SC), uma das ferramentas mais utilizadas na avaliação teórica e clínica do sistema visual humano. A SC tem se estabelecido como uma técnica que permite estudar e identificar a forma como determinadas patologias acometem a visão e o sistema nervoso central. Participaram deste estudo 33 voluntários, com idades entre 19 e 37 anos e acuidade visual normal ou corrigida. Dentre eles, 11 foram diagnosticados com transtorno depressivo maior, segundo os critérios do DSM-IV e se encontravam devidamente medicados (Grupo Depressão - GD). Os outros 22 eram isentos de patologia neuropsiquiátrica e gozavam de boa saúde (Grupo Controle - GC). A SC foi mensurada através do método psicofísico da escolha forçada entre duas alternativas temporais (2AF). Foram testadas as frequências espaciais lineares de 0,5; 2,5; 10 e 20 ciclos por grau de ângulo visual (cpg) e as angulares de 2, 4, 24, 48 e 96 ciclos/360º. Os estímulos eram circulares e foram apresentados em um monitor de vídeo LG, RGB de 19 polegadas (resolução de tela de 1024 x 768 pixels a 75 Hz) conectado a um microcomputador e um BITS ++ (Cambridge Research Systems). A luminância média da tela foi de 41,05 cd/m² mensurada por um fotômetro ColorCAL (Cambridge Research Systems). As medidas foram realizadas a uma distância de 300 cm da tela do monitor. Os estímulos foram exibidos em pares sucessivos, um com a frequência testada (espaciais lineares ou angulares) e o outro era um círculo cinza com luminância homogênea. Os participantes foram orientados a pressionar o botão do lado esquerdo do mouse, quando o estímulo teste fosse apresentado primeiro, e o botão do lado direito, quando fosse apresentado depois do estímulo com luminância homogênea. Os resultados mostraram um efeito de interação para as frequências espaciais lineares [F(3, 93) = 6,0814, p = 0,0008], o test post-hoc Newmann Kels mostrou diferença significante na frequência de 0,5 cpg. Os resultados para as frequências angulares mostraram um efeito de interação marginalmente significante. As análises com post-hoc mostraram uma diferença marginalmente significante para frequência de 2 ciclos/360º. Esses resultados sugerem alterações na SC de pacientes com depressão maior medicados / The present study aimed to investigate potential changes in visual perception related to major depression. Then, we measure of contrast sensitivity (CS), one of the most used tools to study the humans visual system. The CS has established itself as one tool that allows to study and identify how certain diseases affect the vision and the central nervous system. The study included 33 volunteers aged between 19 and 37 years and they are normal or corrected visual acuity. 11 were diagnosed with major depressive disorder according to DSM-IV and were treated with antidepressants (Depression Group - DG). The other 22 were free of neuropsychiatric disease and were in good health (Control Group - CG). The CS was measured using the psychophysical method of forced choice between two temporal alternatives (2AF). Were tested linear spatial frequencies of 0.5, 2.5, 10 and 20 cycles per degree of visual angle (cpd) and the angular frequencies of 2, 4, 24, 48 and 96 cycles/360º. The stimuli were circular and were presented on a video monitor LG 19-inch RGB (screen resolution of 1024 x 768 pixels at 75 Hz) connected to a microcomputer and a BITS + + (Cambridge Research Systems). The average luminance of the display was 41.05 cd / m² measured by a photometer ColorCal (Cambridge Research Systems). The measurements were performed at a distance of 300 cm from the monitor screen. The stimuli were displayed in successive pairs, with a frequency tested (linear or angular) and the other was a gray circle with uniform luminance. Participants were instructed to press the left mouses button when the test stimulus was presented first, and the right button when the stimulus was presented second. The results showed an interaction effect for the linear spatial frequency [F (3, 93) = 6.0814, p = 0.0008], the test post-hoc Newmann Kels showed significant difference in frequency of 0.5 cpd. The results for the angular frequencies showed a marginally significant effect of interaction. The analyzes with post-hoc showed a marginally significant difference for frequency of 2 cycles/360º. These results suggest changes in the CS of patients with major depression medicated
3

Reconhecimento de faces com filtragens de frequências espaciais altas e baixas nos hemicampos visuais direito e esquerdo / Facial recognition in high and low spatial frequency filtering in the right and in the left hemifields

Moraes Júnior, Rui de 06 March 2012 (has links)
O presente estudo teve por objetivo investigar se o reconhecimento de faces ocorre prioritariamente por processamento analítico ou holístico nos hemisférios cerebrais em homens e mulheres por meio do estudo do espectro de frequência espacial. Para isso, no Experimento I, 40 voluntários (20 mulheres) realizaram duas sessões. Em cada uma delas foram memorizadas 14 faces para uma tarefa de reconhecimento. Nesta, cada face foi apresentada por 300 ms, e em uma das sessões as imagens foram apresentadas somente no hemicampo visual direito, e noutra só no hemicampo visual esquerdo por meio de uma adaptação do método do campo visual dividido. A tarefa dos participantes foi assinalar o grau de confiabilidade de sua resposta (confidence rating method) ao discriminar as faces memorizadas de outras inéditas. Os estímulos da tarefa de reconhecimento foram apresentados em três condições: (1) em frequências espaciais altas, FEAs, (2) em frequências espaciais baixas, FEBs, e (3) sem filtragem, SFE. As frequências de respostas aos graus de confiabilidade permitiram calcular as curvas ROC e os parâmetros Az e da da Teoria de Deteção de Sinal. Por meio destes, foi comparado o desempenho do reconhecimento facial nas diferentes faixas do espectro espacial. De maneira complementar, foi realizado uma ANOVA para testar a diferença dos tempos de resposta no reconhecimento entre as filtragens. Não foi evidenciada especialização hemisférica no reconhecimento de faces com filtragem espacial. Mas homens, de modo tênue, perceberam melhor faces em FEBs e mulheres em FEAs. Para verificar se este resultado não se deu em função da apresentação lateralizada, foi realizado o Experimento II, nos moldes de uma sessão experimental do Experimento I, mas com apresentação central. Vinte voluntários (10 mulheres) participaram do experimento. Novamente, homens e mulheres foram mais sensíveis às faces em FEBs e FEAs, respectivamente. Deste modo, conclui-se que homens utilizam mais recursos holísticos e mulheres, por sua vez, operações analíticas. Os resultados dão bases para a não ocorrência de especialização hemisférica de frequencias espaciais no reconhecimento de faces em longos tempos de exposições. A diferença de sexo observada e nos atenta para a necessidade de controle amostral por sexo em pesquisas da área. / This study aimed to investigate whether face recognition occurs primarily by analytic or holistic processing in the cerebral hemispheres of men and women through the study of the spatial frequency spectrum. Therefore, in Experiment I, 40 volunteers (20 women) performed two sessions. In each of, 14 faces were memorized for a recognition task and each face was presented for 300 ms. Images were presented only in the right visual hemifield in a session, and in another only in the left visual hemifield by means of an adaptation of the method of divided visual field. The participants task was to assign the reliability of their response (confidence rating method) to discriminate the study faces from distractors. The recognition task stimuli were presented in three conditions: (1) at high spatial frequencies, FEAs, (2) at low spatial frequencies, FEBs, and (3) unfiltered, SFE. The frequencies of responses to the degree of reliability used to calculate ROC curves and parameters Az and da of the Signal Detection Theory compared the performance of face recognition in different bands of the spectrum. In a complementary way, an ANOVA was conducted to test response times differences in the recognition between filtering. There was no evidence of hemispheric specialization in face recognition with spatial filtering. But men had better performance in recognizing faces in FEBs and women faces in FEAs. To verify that this result was not in function of lateralized presentation, Experiment II was conducted, along the lines of an experimental session of Experiment I, but with central presentation. Twenty volunteers (10 women) participated in the experiment. Again, men and women were more sensitive to faces in FEBs and FEAs, respectively. Thus it follows that men use holistic resources and women analytical operations. The results provide no basis for the occurrence of hemispheric specialization of spatial frequencies in face recognition over long exposure times. The sex difference observed brings us to the need for control sample by sex in spatial frequency research.
4

Reconhecimento de faces com filtragens de frequências espaciais altas e baixas nos hemicampos visuais direito e esquerdo / Facial recognition in high and low spatial frequency filtering in the right and in the left hemifields

Rui de Moraes Júnior 06 March 2012 (has links)
O presente estudo teve por objetivo investigar se o reconhecimento de faces ocorre prioritariamente por processamento analítico ou holístico nos hemisférios cerebrais em homens e mulheres por meio do estudo do espectro de frequência espacial. Para isso, no Experimento I, 40 voluntários (20 mulheres) realizaram duas sessões. Em cada uma delas foram memorizadas 14 faces para uma tarefa de reconhecimento. Nesta, cada face foi apresentada por 300 ms, e em uma das sessões as imagens foram apresentadas somente no hemicampo visual direito, e noutra só no hemicampo visual esquerdo por meio de uma adaptação do método do campo visual dividido. A tarefa dos participantes foi assinalar o grau de confiabilidade de sua resposta (confidence rating method) ao discriminar as faces memorizadas de outras inéditas. Os estímulos da tarefa de reconhecimento foram apresentados em três condições: (1) em frequências espaciais altas, FEAs, (2) em frequências espaciais baixas, FEBs, e (3) sem filtragem, SFE. As frequências de respostas aos graus de confiabilidade permitiram calcular as curvas ROC e os parâmetros Az e da da Teoria de Deteção de Sinal. Por meio destes, foi comparado o desempenho do reconhecimento facial nas diferentes faixas do espectro espacial. De maneira complementar, foi realizado uma ANOVA para testar a diferença dos tempos de resposta no reconhecimento entre as filtragens. Não foi evidenciada especialização hemisférica no reconhecimento de faces com filtragem espacial. Mas homens, de modo tênue, perceberam melhor faces em FEBs e mulheres em FEAs. Para verificar se este resultado não se deu em função da apresentação lateralizada, foi realizado o Experimento II, nos moldes de uma sessão experimental do Experimento I, mas com apresentação central. Vinte voluntários (10 mulheres) participaram do experimento. Novamente, homens e mulheres foram mais sensíveis às faces em FEBs e FEAs, respectivamente. Deste modo, conclui-se que homens utilizam mais recursos holísticos e mulheres, por sua vez, operações analíticas. Os resultados dão bases para a não ocorrência de especialização hemisférica de frequencias espaciais no reconhecimento de faces em longos tempos de exposições. A diferença de sexo observada e nos atenta para a necessidade de controle amostral por sexo em pesquisas da área. / This study aimed to investigate whether face recognition occurs primarily by analytic or holistic processing in the cerebral hemispheres of men and women through the study of the spatial frequency spectrum. Therefore, in Experiment I, 40 volunteers (20 women) performed two sessions. In each of, 14 faces were memorized for a recognition task and each face was presented for 300 ms. Images were presented only in the right visual hemifield in a session, and in another only in the left visual hemifield by means of an adaptation of the method of divided visual field. The participants task was to assign the reliability of their response (confidence rating method) to discriminate the study faces from distractors. The recognition task stimuli were presented in three conditions: (1) at high spatial frequencies, FEAs, (2) at low spatial frequencies, FEBs, and (3) unfiltered, SFE. The frequencies of responses to the degree of reliability used to calculate ROC curves and parameters Az and da of the Signal Detection Theory compared the performance of face recognition in different bands of the spectrum. In a complementary way, an ANOVA was conducted to test response times differences in the recognition between filtering. There was no evidence of hemispheric specialization in face recognition with spatial filtering. But men had better performance in recognizing faces in FEBs and women faces in FEAs. To verify that this result was not in function of lateralized presentation, Experiment II was conducted, along the lines of an experimental session of Experiment I, but with central presentation. Twenty volunteers (10 women) participated in the experiment. Again, men and women were more sensitive to faces in FEBs and FEAs, respectively. Thus it follows that men use holistic resources and women analytical operations. The results provide no basis for the occurrence of hemispheric specialization of spatial frequencies in face recognition over long exposure times. The sex difference observed brings us to the need for control sample by sex in spatial frequency research.
5

Processamento visual de contraste em pacientes com depressão maior

Aline Mendes Lacerda 26 June 2012 (has links)
O presente estudo teve como objetivo investigar possíveis alterações na percepção visual relacionadas à depressão maior. Para tanto, realizou-se medidas de sensibilidade ao contraste (SC), uma das ferramentas mais utilizadas na avaliação teórica e clínica do sistema visual humano. A SC tem se estabelecido como uma técnica que permite estudar e identificar a forma como determinadas patologias acometem a visão e o sistema nervoso central. Participaram deste estudo 33 voluntários, com idades entre 19 e 37 anos e acuidade visual normal ou corrigida. Dentre eles, 11 foram diagnosticados com transtorno depressivo maior, segundo os critérios do DSM-IV e se encontravam devidamente medicados (Grupo Depressão - GD). Os outros 22 eram isentos de patologia neuropsiquiátrica e gozavam de boa saúde (Grupo Controle - GC). A SC foi mensurada através do método psicofísico da escolha forçada entre duas alternativas temporais (2AF). Foram testadas as frequências espaciais lineares de 0,5; 2,5; 10 e 20 ciclos por grau de ângulo visual (cpg) e as angulares de 2, 4, 24, 48 e 96 ciclos/360º. Os estímulos eram circulares e foram apresentados em um monitor de vídeo LG, RGB de 19 polegadas (resolução de tela de 1024 x 768 pixels a 75 Hz) conectado a um microcomputador e um BITS ++ (Cambridge Research Systems). A luminância média da tela foi de 41,05 cd/m² mensurada por um fotômetro ColorCAL (Cambridge Research Systems). As medidas foram realizadas a uma distância de 300 cm da tela do monitor. Os estímulos foram exibidos em pares sucessivos, um com a frequência testada (espaciais lineares ou angulares) e o outro era um círculo cinza com luminância homogênea. Os participantes foram orientados a pressionar o botão do lado esquerdo do mouse, quando o estímulo teste fosse apresentado primeiro, e o botão do lado direito, quando fosse apresentado depois do estímulo com luminância homogênea. Os resultados mostraram um efeito de interação para as frequências espaciais lineares [F(3, 93) = 6,0814, p = 0,0008], o test post-hoc Newmann Kels mostrou diferença significante na frequência de 0,5 cpg. Os resultados para as frequências angulares mostraram um efeito de interação marginalmente significante. As análises com post-hoc mostraram uma diferença marginalmente significante para frequência de 2 ciclos/360º. Esses resultados sugerem alterações na SC de pacientes com depressão maior medicados / The present study aimed to investigate potential changes in visual perception related to major depression. Then, we measure of contrast sensitivity (CS), one of the most used tools to study the humans visual system. The CS has established itself as one tool that allows to study and identify how certain diseases affect the vision and the central nervous system. The study included 33 volunteers aged between 19 and 37 years and they are normal or corrected visual acuity. 11 were diagnosed with major depressive disorder according to DSM-IV and were treated with antidepressants (Depression Group - DG). The other 22 were free of neuropsychiatric disease and were in good health (Control Group - CG). The CS was measured using the psychophysical method of forced choice between two temporal alternatives (2AF). Were tested linear spatial frequencies of 0.5, 2.5, 10 and 20 cycles per degree of visual angle (cpd) and the angular frequencies of 2, 4, 24, 48 and 96 cycles/360º. The stimuli were circular and were presented on a video monitor LG 19-inch RGB (screen resolution of 1024 x 768 pixels at 75 Hz) connected to a microcomputer and a BITS + + (Cambridge Research Systems). The average luminance of the display was 41.05 cd / m² measured by a photometer ColorCal (Cambridge Research Systems). The measurements were performed at a distance of 300 cm from the monitor screen. The stimuli were displayed in successive pairs, with a frequency tested (linear or angular) and the other was a gray circle with uniform luminance. Participants were instructed to press the left mouses button when the test stimulus was presented first, and the right button when the stimulus was presented second. The results showed an interaction effect for the linear spatial frequency [F (3, 93) = 6.0814, p = 0.0008], the test post-hoc Newmann Kels showed significant difference in frequency of 0.5 cpd. The results for the angular frequencies showed a marginally significant effect of interaction. The analyzes with post-hoc showed a marginally significant difference for frequency of 2 cycles/360º. These results suggest changes in the CS of patients with major depression medicated

Page generated in 0.0507 seconds