• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 94
  • 5
  • 5
  • 3
  • 3
  • 1
  • Tagged with
  • 113
  • 91
  • 51
  • 33
  • 33
  • 33
  • 33
  • 33
  • 33
  • 32
  • 31
  • 28
  • 26
  • 25
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Study of heat transfer and flow pattern in a multiphase fuel oil circular tank

Sancet, Aitor January 2009 (has links)
<p>This is a thesis work proposed by Sweco System in order to carry out a study related to the heating system of a circular fuel oil storage tank or cistern. The study tank is a 23m diameter and 18m height with a storage capacity of around 7500m3 of Eo5 heavy fuel oil. The content ought to be at a minimum storage temperature of 50ºC so that the fuel oil is fluid enough and operation labors can be adequately performed. In fact, these types of heavy fuel oils have fairly high viscosities at lower temperatures and the heating and pumping system can be compromised at temperatures below the pour point. For this purpose a heating system is installed to maintain the fluid warm. So far the system was operated by an oil burner but there are plans to its replacement by a District Heating-heat exchanger combo. Thereby, tank heating needs, flow and thermal patterns and heat transfer within it are principally studied.</p><p> </p><p>Tank boundaries are studied and their thermal resistances are calculated in order to dimension heat supply capacity. The study implies Finite Elements (Comsol Multiphysics) and Finite Volume (Fluent) analysis to work out some stationary heat transfer by conduction cases on some parts and thermal bridges present on these boundaries. Afterwards both cooling and heating processes of the fuel oil are studied using several strategies: basic models and Computational Fluid Dynamics (CFD). CFD work with Fluent is focused on optimizing inlet and outlet topologies. Understanding the cooling process is sought as well; Fluent CFD transient models are simulated in this way as well. Additionally the effect of filling levels is taken into account leading to a multiphase (fuel oil and air) flow cases where especially heating coupling of both phases is analyzed.</p><p> </p><p>Results show that maximum heat supply needs are around 80kW when the tank temperature is around 60ºC and 70kW when it is around 50ºC. Expectedly the main characteristic of the flow turns out to be the buoyancy driven convective pattern. K-ε turbulence viscous models are applied to both heating and cooling processes showing thermal stratification, especially at the bottom of the tank. Hotter fluid above follows very complex flow patterns. During the heating processes models used predict fairly well mixed and homogenous temperature distribution regardless small stratification at the bottom of the tank. In this way no concrete inlet-outlet configuration shows clear advantages over the rest. Due to the insulation of the tank, low thermal conductivity of the fluid and vast amount of mass present in the tank, the cooling process is slow (fluid average temperature drops around 5.7 ºC from 60ºC in 15 days when the tank is full and ambient temperature is considered to be at -20ºC) and lies somewhere in the middle between the solid rigid and perfect mixture cooling processes. However, due to stratification some parts of the fluid reach minimum admissible temperatures much faster than average temperature does. On the other hand, as expected, air phase acts as an additional thermal resistance; anyhow the cooling process is still faster for lower filling levels than the full one.</p> / <p>El presente proyecto fue propuesto por Sweco Systems para llevar a cabo un estudio relacionado con el sistema de calefacción de una cisterna o tanque de almacenamiento de fuel oil circular. Dicho tanque tiene 23 m de diámetro  y 18 m de altura con una capacidad de almacenamiento de alrededor de 7500 m<sup>3</sup> de Eo5 fuel oil pesado. El contenido mantenerse a una temperatura mínima de 50 ºC de manera que el fuel oil es suficientemente fluido para que las labores de operación puedan ser ejecutadas adecuadamente. De hecho, estos tipos de fuel oil pesado tienen altas viscosidades a bajas temperaturas y, por tanto, tanto los sistemas de calefacción y como el de bombeo pueden verse comprometidosr a temperaturas por debajo del pour point. Con este fin un sistema de calefacción es instalado para mantener el fluido suficientemente caliente. Hasta el momento, el sistema era operado por un quemador de fuel, sin embargo, hay planes que éste sea sustituido por un combo intercambiador de calor-District Heating. Por lo tanto, principalmente son estudiadas las necesidades de calefacción así como los flujos térmicos y fluidos.</p><p>Se estudian las fronteras del tanque, y sus respectivas resistencias térmicas son calculadas con el fin de dimensionar la capacidad necesaria de suministro de calor. El estudio implica Elementos Finitos (Comsol Multiphysics) y Volúmenes Finitos (Fluent) para elaborar análisis estacionarios de transferencia de calor por conducción en algunos casos. Existen puentes térmicos en las paredes y su importancia es también anallizada. Posteriormente se estudian tanto los procesos de calentamiento y enfriamiento del fuel oil utilizando diversas estrategias: modelos básicos y Dinámica de Fluidos Computacional (CFD). El trabajo con CFD se centra en la optimización de topologías de entradas y salidas del sistema. También es solicitado entender el proceso de enfriamiento; En este sentido, se simulan modelos CFD transitorios de Fluent. Además, el efecto de los niveles de llenado se tiene en cuenta dando lugar a estudios de flujo multifase (fuel oil y aire), haciendo hincapié en el análisis de acoplamiento de transferencia de calor entre las dos fases.</p><p>Los resultados muestran que las necesidades de calefacción máximas son de alrededor de 80kW cuando la temperatura del tanque es de alrededor de 60 º C y 70kW cuando está alrededor de 50 ºC. Como era de esperar, la principal característica de este tipo de flujos es la convección natural resultante de las fuerzas de flotabilidad. Se aplican modelos turbulentos k-ε a los procesos de calentamiento y enfriamiento, mostrando estratificación térmica, sobre todo en la parte inferior de la cisterna. El líquido más caliente que se sitúa encima muestra complejos patrones de flujo. Durante los procesos de calentamiento, los modelos utilizados predicen un buen mezclado y distribución homogénea de la temperatura independientemente de esta pequeña estratificación en la parte inferior de la cisterna. De esta manera, ninguna concreta configuración de entradas-salidas simuladas muestra claras ventajas sobre el resto. Debido al aislamiento de la cisterna, la baja conductividad térmica del fluido y la gran cantidad de masa presente en el tanque el proceso de enfriamiento es lento (la temperatura media del fluido desciende 5.7 º C desde 60 º C en 15 días cuando el tanque está lleno y la temperatura ambiente es de -20 º C) y se encuentra en algún lugar en medio de los procesos de enfriamiento del sólido rígido y perfecta mezcla. Sin embargo, debido a la estratificación, algunas partes el líquido alcanzan la temperatura mínima admisible mucho más rápido que la media de temperatura. Por otra parte, como se esperaba, la fase de aire actúa como una resistencia térmica adicional, de todos modos, el proceso de enfriamiento es aún más rápido para niveles de llenado más bajos que el lleno.</p>
112

Study of heat transfer and flow pattern in a multiphase fuel oil circular tank

Sancet, Aitor January 2009 (has links)
This is a thesis work proposed by Sweco System in order to carry out a study related to the heating system of a circular fuel oil storage tank or cistern. The study tank is a 23m diameter and 18m height with a storage capacity of around 7500m3 of Eo5 heavy fuel oil. The content ought to be at a minimum storage temperature of 50ºC so that the fuel oil is fluid enough and operation labors can be adequately performed. In fact, these types of heavy fuel oils have fairly high viscosities at lower temperatures and the heating and pumping system can be compromised at temperatures below the pour point. For this purpose a heating system is installed to maintain the fluid warm. So far the system was operated by an oil burner but there are plans to its replacement by a District Heating-heat exchanger combo. Thereby, tank heating needs, flow and thermal patterns and heat transfer within it are principally studied.   Tank boundaries are studied and their thermal resistances are calculated in order to dimension heat supply capacity. The study implies Finite Elements (Comsol Multiphysics) and Finite Volume (Fluent) analysis to work out some stationary heat transfer by conduction cases on some parts and thermal bridges present on these boundaries. Afterwards both cooling and heating processes of the fuel oil are studied using several strategies: basic models and Computational Fluid Dynamics (CFD). CFD work with Fluent is focused on optimizing inlet and outlet topologies. Understanding the cooling process is sought as well; Fluent CFD transient models are simulated in this way as well. Additionally the effect of filling levels is taken into account leading to a multiphase (fuel oil and air) flow cases where especially heating coupling of both phases is analyzed.   Results show that maximum heat supply needs are around 80kW when the tank temperature is around 60ºC and 70kW when it is around 50ºC. Expectedly the main characteristic of the flow turns out to be the buoyancy driven convective pattern. K-ε turbulence viscous models are applied to both heating and cooling processes showing thermal stratification, especially at the bottom of the tank. Hotter fluid above follows very complex flow patterns. During the heating processes models used predict fairly well mixed and homogenous temperature distribution regardless small stratification at the bottom of the tank. In this way no concrete inlet-outlet configuration shows clear advantages over the rest. Due to the insulation of the tank, low thermal conductivity of the fluid and vast amount of mass present in the tank, the cooling process is slow (fluid average temperature drops around 5.7 ºC from 60ºC in 15 days when the tank is full and ambient temperature is considered to be at -20ºC) and lies somewhere in the middle between the solid rigid and perfect mixture cooling processes. However, due to stratification some parts of the fluid reach minimum admissible temperatures much faster than average temperature does. On the other hand, as expected, air phase acts as an additional thermal resistance; anyhow the cooling process is still faster for lower filling levels than the full one. / El presente proyecto fue propuesto por Sweco Systems para llevar a cabo un estudio relacionado con el sistema de calefacción de una cisterna o tanque de almacenamiento de fuel oil circular. Dicho tanque tiene 23 m de diámetro  y 18 m de altura con una capacidad de almacenamiento de alrededor de 7500 m3 de Eo5 fuel oil pesado. El contenido mantenerse a una temperatura mínima de 50 ºC de manera que el fuel oil es suficientemente fluido para que las labores de operación puedan ser ejecutadas adecuadamente. De hecho, estos tipos de fuel oil pesado tienen altas viscosidades a bajas temperaturas y, por tanto, tanto los sistemas de calefacción y como el de bombeo pueden verse comprometidosr a temperaturas por debajo del pour point. Con este fin un sistema de calefacción es instalado para mantener el fluido suficientemente caliente. Hasta el momento, el sistema era operado por un quemador de fuel, sin embargo, hay planes que éste sea sustituido por un combo intercambiador de calor-District Heating. Por lo tanto, principalmente son estudiadas las necesidades de calefacción así como los flujos térmicos y fluidos. Se estudian las fronteras del tanque, y sus respectivas resistencias térmicas son calculadas con el fin de dimensionar la capacidad necesaria de suministro de calor. El estudio implica Elementos Finitos (Comsol Multiphysics) y Volúmenes Finitos (Fluent) para elaborar análisis estacionarios de transferencia de calor por conducción en algunos casos. Existen puentes térmicos en las paredes y su importancia es también anallizada. Posteriormente se estudian tanto los procesos de calentamiento y enfriamiento del fuel oil utilizando diversas estrategias: modelos básicos y Dinámica de Fluidos Computacional (CFD). El trabajo con CFD se centra en la optimización de topologías de entradas y salidas del sistema. También es solicitado entender el proceso de enfriamiento; En este sentido, se simulan modelos CFD transitorios de Fluent. Además, el efecto de los niveles de llenado se tiene en cuenta dando lugar a estudios de flujo multifase (fuel oil y aire), haciendo hincapié en el análisis de acoplamiento de transferencia de calor entre las dos fases. Los resultados muestran que las necesidades de calefacción máximas son de alrededor de 80kW cuando la temperatura del tanque es de alrededor de 60 º C y 70kW cuando está alrededor de 50 ºC. Como era de esperar, la principal característica de este tipo de flujos es la convección natural resultante de las fuerzas de flotabilidad. Se aplican modelos turbulentos k-ε a los procesos de calentamiento y enfriamiento, mostrando estratificación térmica, sobre todo en la parte inferior de la cisterna. El líquido más caliente que se sitúa encima muestra complejos patrones de flujo. Durante los procesos de calentamiento, los modelos utilizados predicen un buen mezclado y distribución homogénea de la temperatura independientemente de esta pequeña estratificación en la parte inferior de la cisterna. De esta manera, ninguna concreta configuración de entradas-salidas simuladas muestra claras ventajas sobre el resto. Debido al aislamiento de la cisterna, la baja conductividad térmica del fluido y la gran cantidad de masa presente en el tanque el proceso de enfriamiento es lento (la temperatura media del fluido desciende 5.7 º C desde 60 º C en 15 días cuando el tanque está lleno y la temperatura ambiente es de -20 º C) y se encuentra en algún lugar en medio de los procesos de enfriamiento del sólido rígido y perfecta mezcla. Sin embargo, debido a la estratificación, algunas partes el líquido alcanzan la temperatura mínima admisible mucho más rápido que la media de temperatura. Por otra parte, como se esperaba, la fase de aire actúa como una resistencia térmica adicional, de todos modos, el proceso de enfriamiento es aún más rápido para niveles de llenado más bajos que el lleno.
113

Ceux qui ont dit "Non": histoire du mouvement des marins chiliens opposés au coup d'Etat de 1973

Magasich-Airola, Jorge 30 November 2007 (has links)
L’opposition au coup d’État de 1973 au sein des forces armées chiliennes a été significative. En effet, un nombre symptomatique d’officiers, tout comme un nombre considérable des membres de la troupe, ont répondu « Non » à l’ordre de renverser le gouvernement légitime. Ces militaires légitimistes ont été particulièrement actifs dans la Marine, institution qui vit un conflit entre sa structure archaïque et le statut social de technicien acquis par les marins. Ce derniers perçoivent, avant d’autres secteurs de la société, le danger d’un coup d’État et vont tenter de s’organiser, tout d’abord pour informer les autorités et ensuite pour tenter de le faire avorter. <p>Notre objectif est de retracer l’histoire du mouvement des marins légitimistes et notre hypothèse de travail est que le coup d’État de 1973 n’est pas l’œuvre de l’armée mais d’une fraction de celle-ci.<p><p>Nous avons consulté quatre catégories de sources :<p>1) La presse :6 quotidiens et 2 hebdomadaires opposés au gouvernement d’Allende; 4 quotidiens, 2 hebdomadaires et un bimensuel proches du gouvernement ou de gauche. <p>2) Les essais, documents politiques, témoignages et mémoires, particulièrement les mémoires des quatre amiraux organisateurs du coup d’État. <p>3) Les procès entamés contre les marins dès la fin du gouvernement d’Allende, dont les 6.000 pages du célèbre procès 3926 contre les marins de la flotte.<p>4) Nous avons interviewé 30 marins, ce qui correspond à environ un tiers des marins condamnés par les tribunaux navals sous la dictature. En outre, nous avons interviewé, des militants, des avocats, un procureur, un général de l’aviation opposé au coup d’État, un officier de la Marine opposé au coup d’État et un officier de la Marine favorable au coup d’État. Au total 52 interviews qui totalisent un bon millier de pages.<p><p>L’introduction présente le sujet et explique sa pertinence :les réunions entre les marins et les dirigeants politiques restent un événement souvent cité dans l’historiographie qui justifie le coup d’État.<p>Le ch. I est un travail de compilation sur l’histoire des révoltes de marins au XXe siècle, pour identifier les éléments communs entre elles.<p>Le ch. II tente de situer la Marine chilienne dans son contexte historique et social, rappelant les conflits qui ont secoué la force navale et sa réorganisation lors du début de la Guerre froide et décrivant le contenu de l’enseignement donné à l’École navale des officiers. <p>Le ch. III décrit la vie sociale dans la Marine de 1970 –l’année de l’élection présidentielle– surtout les relations difficiles entre la troupe et les officiers. Celles-ci se manifestent à travers des réactions contradictoires au résultat de l’élection. Pendant les premiers mois du gouvernement d’Allende, un nombre croissant d’officiers manifeste son opposition, alors que des « hommes de mer » (la troupe) s’organisent pour le défendre.<p>Les ch. IV et V couvrent la période qui va de 1971 jusqu’à la première tentative de coup d’État le 29 juin 1973 (el Tanquetazo). Elle est marquée d’une part par l’adhésion de la plupart des officiers aux thèses putschistes, et d’autre part, par un notable développement des groupes de marins antiputschistes. Nous décrivons les relations structurelles entre les officiers et civils conjurés et l’établissement des relations entre des groupes de marins et certains partis politiques de gauche. Ce travail décrit la réunion secrète où plusieurs groupes de marins, tentent d’établir une coordination et discutent s’il faut agir avant que le coup d’État ne soit déclenché ou seulement en réaction à celui-ci.<p>Le chapitre VI couvre les cinq « semaines décisives » qui s’écoulent entre la tentative de putsch du 29 juin et l’arrestation des marins de la flotte, le 5 août 1973. Dans la Marine, la préparation du coup d’État arrive à sa phase finale, avec un affairement perceptible. Beaucoup de marins craignent d’être forcés à y participer. Dans ce contexte, le groupe de marins de la flotte formule une ébauche de plan d’occupation des navires et organise des réunions avec des dirigeants de gauche pour tenter une action qui ferait avorter le coup d’État imminent. Nous avons pu retracer ce plan ainsi que les célèbres réunions avec les dirigeants du PS, du MAPU et du MIR, grâce à plusieurs témoignages de marins et de « civils » présents dans ces réunions.<p>Le chapitre VII décrit la période entre l’arrestation des marins et les semaines qui suivent le coup d’État, décrivant les premières tortures, la difficile situation du gouvernement d’Allende, qui attaque en justice les marins « infiltrés », et le débat politique et juridique suscité par les arrestations et tortures, un des derniers débats démocratiques. <p>Le chapitre VIII expose la poursuite des procès sous la dictature. Parmi les avocats pro deo qui se contentent d’une timide défense pour la forme, nous avons trouvé une défense exceptionnelle des marins sur le plan politique :« le devoir de tout militaire est de défendre le gouvernement légitime », affirme l’avocate Lidia Hogtert, une dame de 75 ans, qui, en 1975, ose défier la justice militaire. En 1988, à la fin de la dictature, lorsque l’ancien secrétaire du MAPU Oscar Garretón se présente devant la justice navale, le cas connaît un nouveau retentissement :après plusieurs condamnations par des tribunaux militaires, Garreton obtient une victoire complète à la Cour Suprême. Il est acquitté de toute accusation pour « sédition et mutinerie ». / Doctorat en Histoire, art et archéologie / info:eu-repo/semantics/nonPublished

Page generated in 0.0457 seconds