Spelling suggestions: "subject:"fullskala""
1 |
Utveckling av en beräkningsmodell för biogasproduktion / Development of a model for calculating biogasproductionMellbin, Marcus January 2010 (has links)
<p>A growing interest for the climate and the environment has led to an increased interest forenvironmentally friendly and renewable energy sources, such as biogas. Planning new biogasplants requires a decision basis including facts about approximate amounts of biogas possibleto produce at the plant. The purpose of this thesis is to develop a model that calculates theapproximate biogas and digestate production from a planned or existing biogas plant.Developing the model required a literature review and studies of calculations concerningbiogas and digestate production performed by WSP Sweden AB. As a complement to themodel development, facts about substrates for biogas production were compiled through aliterature review. In addition the methane potential from selected materials was determined bybatch experiments. Two full scale experiments were also studied to compare results from themodel with results from full scale biogas production.This thesis work resulted in a model for calculating biogas, methane and digestate production,including calculations of nutrient content in the digestate, from a given amount of substrate.The model was constructed in Microsoft Office Excel and complemented by a chart,containing template facts for different biogas substrates. The template facts, together with themodel, make it possible to perform calculations of biogas production before any up-to-dateinvestigations are made of the biogas substrate.Comparing results of biogas production calculated with the model with values of biogasproduction from a full scale biogas plant showed that the calculated values where within, orjust outside, the standard deviation of the full scale values. The calculated values from themodel also turned out to be in general lower than the full scale values, which indicate that themodel doesn’t overestimate the biogas production. However, the uncertainties of the values inthe template facts chart and the simplifications made in the model both contribute in tomaking the model calculations somewhat uncertain. The calculations should thus only be seenas an indication of the possible biogas production from planned or existing biogas plants andnot as an exact prediction.</p>
|
2 |
Utveckling av en beräkningsmodell för biogasproduktion / Development of a model for calculating biogasproductionMellbin, Marcus January 2010 (has links)
A growing interest for the climate and the environment has led to an increased interest forenvironmentally friendly and renewable energy sources, such as biogas. Planning new biogasplants requires a decision basis including facts about approximate amounts of biogas possibleto produce at the plant. The purpose of this thesis is to develop a model that calculates theapproximate biogas and digestate production from a planned or existing biogas plant.Developing the model required a literature review and studies of calculations concerningbiogas and digestate production performed by WSP Sweden AB. As a complement to themodel development, facts about substrates for biogas production were compiled through aliterature review. In addition the methane potential from selected materials was determined bybatch experiments. Two full scale experiments were also studied to compare results from themodel with results from full scale biogas production.This thesis work resulted in a model for calculating biogas, methane and digestate production,including calculations of nutrient content in the digestate, from a given amount of substrate.The model was constructed in Microsoft Office Excel and complemented by a chart,containing template facts for different biogas substrates. The template facts, together with themodel, make it possible to perform calculations of biogas production before any up-to-dateinvestigations are made of the biogas substrate.Comparing results of biogas production calculated with the model with values of biogasproduction from a full scale biogas plant showed that the calculated values where within, orjust outside, the standard deviation of the full scale values. The calculated values from themodel also turned out to be in general lower than the full scale values, which indicate that themodel doesn’t overestimate the biogas production. However, the uncertainties of the values inthe template facts chart and the simplifications made in the model both contribute in tomaking the model calculations somewhat uncertain. The calculations should thus only be seenas an indication of the possible biogas production from planned or existing biogas plants andnot as an exact prediction.
|
3 |
Evaluation of a concrete plug : From the Dome Plug Experiment DOMPLU at Äspö HRLKristiansson, Anders January 2014 (has links)
In SKB’s Äspö Hard Rock Laboratory (HRL) a full scale test of a concrete plug,part of a sealing structure for the depository of spent nuclear fuel, has been carriedout. The aim of this thesis is to evaluate the behavior of the concrete plug and howit corresponds to assumptions made during the design. The concrete plug is domeshaped, un-reinforced and casted in situ with low-pH concrete. It will be exposed tohigh water and swelling pressures and designed for a life span of 100 years. Duringthe first years it shall also prevent water leakage from the inside of the depositiontunnel. Before the pressure is applied, the concrete plug is assumed to de-bond fromthe rock due to autogenous and cooling shrinkage. The gap between the concrete androck is then grouted during cooling and the concrete plug will hence be prestressedwhen the cooling is stopped. The concrete plug is analyzed with the measurement data from the full scale testwith comparisons to results from finite element simulations. The performed measurementsinclude form pressure, internal strain and temperature, concrete plugdisplacements in the tunnel alignment, displacements relative to the rock and ambienttemperatures. Two assumptions have been made during the evaluation; fullbond to the rock or no bond to the rock. The results are also compared to twosimilar experiment that were previously performed. The results indicate that the concrete did de-bond from the rock before grouting tosome extent. It is plausible that a selective de-bonding was obtained. Due to highwater leakage, were cables for the measurement equipment are drawn out from theconcrete plug, the concrete plug was not exposed to the planed maximum pressureload. Results indicate that a water pressure is acting on the concrete plug frominside the rock slot which was not assumed during the design. / I SKB:s Äspölaboratoriet har ett fullskaleförsök på en betongplugg, del av ett pluggsystemför förvaret av kärnavfall, utförts. Syftet med denna uppsats var attutvärdera betongpluggens beteende under fullskaleförsöket och hur det förhållersig till gjorda antaganden under dess utformning. Betongpluggen är kupolformad,oarmerad och platsgjuten med låg-pH-betong. Höga vatten- och svälltryck kommerverka på betongpluggen som är utformad för en livstid på 100 år. Under deförsta åren ska den även motverka läckage från insidan av deponeringstunneln. Innantrycklasten läggs på är det antaget att betongpluggen släpper från berget till följd avautogen krympning och kylning. Utrymmet mellan betongen och berget injekterasoch betongpluggen kommer således vara förspänd efter att kylningen upphört. Betongpluggen är analyserad med mätdata från fullskaleförsöket som jämförts medresultat från finita element analyser. Mätningarna inkluderar formtryck, inre töjningaroch temperaturer, deformationer i tunnelriktningen, deformationer relativt bergetoch lufttemperatur utanför betongpluggen. Två antaganden har gjorts under utvärderingen;att betongen är fast i berget eller att den är fri från berget. Resultaten jämförsäven med två liknande fullskaleförsök som utförts tidigare. Resultaten tyder på att betongpluggen till viss del släppt från berget innan injekteringen.Det är troligt att den släppt på vissa ställen och på andra inte. På grundav för högt vattenläckage där de ingjutna mätinstrumentens kabelgenomföring utförts,kunde inte betongpluggen belastas till det maximala tryck som var planerat.Resultaten tyder på att ett vattentryck verkar på betongpluggen mellan berget ochbetongen vilket inte var antaget under konstruktionen.
|
4 |
Robust and Durable Vacuum Insulation Technology for BuildingsKarami, Peyman January 2015 (has links)
Today’s buildings are responsible for 40% of the world’s energy use and also a substantial share of the Global Warming Potential (GWP). In Sweden, about 21% of the energy use can be related to the heat losses through the climatic envelope. The “Million Program” (Swedish: Miljonprogrammet) is a common name for about one million housing units, erected between 1965 and 1974 and many of these buildings suffer from poor energy performance. An important aim of this study was to access the possibilities of using Vacuum Insulation Panels (VIPs) in buildings with emphasis on the use of VIPs for improving the thermal efficiency of the “Million Program” buildings. The VIPs have a thermal resistance of about 8-10 times better than conventional insulations and offer unique opportunities to reduce the thickness of the thermal insulation. This thesis is divided into three main subjects. The first subject aims to investigate new alternative VIP cores that may reduce the market price of VIPs. Three newly developed nanoporous silica were tested using different steady-state and transient methods. A new self-designed device, connected to a Transient Plane Source (TPS) instrument was used to determine the thermal conductivity of granular powders at different gaseous pressure combined with different mechanical loads. The conclusion was that the TPS technique is less suitable for conducting thermal conductivity measurements on low-density nanoporous silica powders. However, deviations in the results are minimal for densities above a limit at which the pure conduction becomes dominant compared to heat transfer by radiation. The second subject of this work was to propose a new and robust VIP mounting system, with minimized thermal bridges, for improving the thermal efficiency of the “Million Program” buildings. On the basis of the parametric analysis and dynamic simulations, a new VIP mounting system was proposed and evaluated through full scale measurements in a climatic chamber. The in situ measurements showed that the suggested new VIP technical solution, consisting of 20mm thick VIPs, can improve the thermal transmittance of the wall, up to a level of 56%. An improved thermal transmittance of the wall at centre-of-panel coordinate of 0.118 to 0.132 W m-2K-1 and a measured centre-of-panel thermal conductivity (λcentre-of-panel) of 7 mW m-1K-1 were reached. Furthermore, this thesis includes a new approach to measure the thermal bridge impacts due to the VIP joints and laminates, through conducting infrared thermography investigations. An effective thermal conductivity of 10.9 mW m-1K-1 was measured. The higher measured centre-of-panel and effective thermal conductivities than the published centre-of-panel thermal conductivity of 4.2 mW m-1K-1 from the VIP manufacturer, suggest that the real thermal performance of VIPs, when are mounted in construction, is comparatively worse than of the measured performance in the laboratory. An effective thermal conductivity of 10.9 mW m-1K-1 will, however, provide an excellent thermal performance to the construction. The third subject of this thesis aims to assess the environmental impacts of production and operation of VIP-insulated buildings, since there is a lack of life cycle analysis of whole buildings with vacuum panels. It was concluded that VIPs have a greater environmental impact than conventional insulation, in all categories except Ozone Depilation Potential. The VIPs have a measurable influence on the total Global Warming Potential and Primary Energy use of the buildings when both production and operation are taken into account. However, the environmental effect of using VIPs is positive when compared to the GWP of a standard building (a reduction of 6%) while the PE is increased by 20%. It was concluded that further promotion of VIPs will benefit from reduced energy use or alternative energy sources in the production of VIP cores while the use of alternative cores and recycling of VIP cores may also help reduce the environmental impact. Also, a sensitivity analysis of this study showed that the choice of VIPs has a significant effect on the environmental impacts, allowing for a reduction of the total PE of a building by 12% and the GWP can be reduced as much as 11% when considering both production and operation of 50 yes. Finally, it’s possible to conclude that the VIPs are very competitive alternative for insulating buildings from the Swedish “Million Program”. Nevertheless, further investigations require for minimizing the measurable environmental impacts that acquired in this LCA study for the VIP-insulated buildings. / Dagens byggnader ansvarar för omkring 40% av världens energianvändning och står också för en väsentlig del av utsläppen av växthusgaser. I Sverige kan ca 21 % av energianvändningen relateras till förluster genom klimatskalet. Miljonprogrammet är ett namn för omkring en miljon bostäder som byggdes mellan 1965 och 1974, och många av dessa byggnader har en dålig energiprestanda efter dagens mått. Huvudsyftet med denna studie har varit att utforska möjligheterna att använda vakuumisoleringspaneler (VIP:ar) i byggnader med viss fokus på tillämpning i Miljonprogrammets byggnader. Med en värmeledningsförmåga som är ca 8 - 10 gånger bättre än för traditionell isolering erbjuder VIP:arna unika möjligheter till förbättrad termisk prestanda med minimal isolerings tjocklek. Denna avhandling hade tre huvudsyften. Det första var att undersöka nya alternativ för kärnmaterial som bland annat kan reducera kostnaden vid produktion av VIP:ar. Tre nyutvecklade nanoporösa kiselpulver har testats med olika stationära och transienta metoder. En inom projektet utvecklad testbädd som kan anslutas till TPS instrument (Transient Plane Source sensor), har använts för att mäta värmeledningsförmågan hos kärnmaterial för VIP:ar, vid varierande gastryck och olika mekaniska laster. Slutsatsen blev att transienta metoder är mindre lämpliga för utföra mätningar av värmeledningsförmåga för nanoporösa kiselpulver låg densitet. Avvikelsen i resultaten är dock minimal för densiteter ovan en gräns då värmeledningen genom fasta material blir dominerande jämfört med värmeöverföring genom strålning. Det andra syftet har varit att föreslå ett nytt monteringssystem för VIP:ar som kan användas för att förbättra energieffektiviteten i byggnader som är typiska för Miljonprogrammet. Genom parametrisk analys och dynamiska simuleringar har vi kommit fram till ett förslag på ett nytt monteringssystem för VIP:ar som har utvärderats genom fullskaleförsök i klimatkammare. Resultaten från fullskaleförsöken visar att den nya tekniska lösningen förbättrar väggens U-värde med upp till 56 %. En förbättrad värmegenomgångskoefficienten för väggen i mitten av en VIP blev mellan 0.118 till 0,132 W m-2K-1 och värmeledningstalet centre-av-panel 7 mW m-1K-1 uppnåddes. Detta arbete innehåller dessutom en ny metod för att mäta köldbryggor i anslutningar med hjälp av infraröd termografi. En effektiv värmeledningsförmåga för 10.9 mW m-1K-1 uppnåddes. Resultaten tyder även på att den verkliga termiska prestandan av VIP:ar i konstruktioner är något sämre än mätvärden för paneler i laboratorium. En effektiv värmeledningsförmåga av 10.9 mW m-1K-1 ger dock väggkonstruktionen en utmärkt termisk prestanda. Det tredje syftet har varit att bedöma miljöpåverkan av en VIP-isolerad byggnad, från produktion till drift, eftersom en livscykelanalys av hela byggnader som är isolerade med vakuumisoleringspaneler inte har gjorts tidigare. Slutsatsen var att VIP:ar har en större miljöpåverkan än traditionell isolering, i alla kategorier förutom ozonnedbrytande potential. VIP:ar har en mätbar påverkan på de totala utsläppen av växthusgaser och primärenergianvändningen i byggnader när både produktion och drift beaktas. Miljöpåverkan av de använda VIP:arna är dock positiv jämfört med GWP av en standardbyggnad (en minskning med 6 %) medan primärenergianvändningen ökade med 20 %. Slutsatsen var att ytterligare användning av VIP:ar gynnas av reducerad energiförbrukning och alternativa energikällor i produktionen av nanoporösa kiselpulver medan användningen av alternativa kärnmaterial och återvinning av VIP kärnor kan hjälpa till att minska miljöpåverkan. En känslighetsanalys visade att valet av VIP:ar har en betydande inverkan på miljöpåverkan, vilket ger möjlighet att reducera den totala användningen av primärenergi i en byggnad med 12 % och utsläppen av växthusgaser kan vara minska, så mycket som 11 % när det gäller både produktion och drift under 50 år. Avslutningsvis är det möjligt att dra slutsatsen att VIP:ar är ett mycket konkurrenskraftigt alternativ för att isolera byggnader som är typiska för Miljonprogrammet. Dock krävs ytterligare undersökningar för att minimera de mätbara miljöeffekter som förvärvats i denna LCA-studie för VIP-isolerade byggnader. / <p>QC 20151109</p> / Simulations of heat and moisture conditions in a retrofit wall construction with Vacuum Insulation Panels / Textural and thermal conductivity properties of a low density mesoporous silica material / A study of the thermal conductivity of granular silica materials for VIPs at different levels of gaseous pressure and external loads / Evaluation of the thermal conductivity of a new nanoporous silica material for VIPs – trends of thermal conductivity versus density / A comparative study of the environmental impact of Swedish residential buildings with vacuum insulation panels / ETICS with VIPs for improving buildings from the Swedish million unit program “Miljonprogrammet”
|
Page generated in 0.0404 seconds