• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 36
  • Tagged with
  • 36
  • 36
  • 28
  • 27
  • 17
  • 14
  • 12
  • 9
  • 8
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Restauração de imagens mamográficas digitais utilizando o filtro de Wiener no domínio de Anscombe e o filtro inverso da MTF no domínio da frequência / Digital mamographic images restoration using Wiener filter in Anscombe domain and inverse MTF filter in frequency domain

Larissa Cristina dos Santos Romualdo 07 October 2009 (has links)
Este trabalho tem por objetivo o desenvolvimento de uma nova técnica de pré-processamento de imagens mamográficas digitais para melhorar o desempenho dos esquemas computacionais de auxílio ao diagnóstico (CAD) e para auxiliar na detecção precoce do câncer de mama. O método proposto efetua uma restauração nas imagens mamográficas utilizando, em uma primeira etapa, a transformada de Anscombe e o filtro de Wiener para redução do ruído quântico. Posteriormente, é utilizado o filtro inverso da função de transferência de modulação (MTF) do sistema de imagem para realce das estruturas de interesse na mamografia, como as microcalcificações, que podem ser um indicativo de câncer de mama em seu estágio inicial. Imagens mamográficas restauradas pelo método proposto foram utilizadas na avaliação de um esquema CAD para detecção automática de microcalcificações. Os resultados mostraram que o desempenho do esquema CAD apresentou uma melhora significativa quando imagens restauradas foram utilizadas, mesmo para imagens de mamas densas, que resultam normalmente em baixa taxa de detecção devido ao baixo contraste. / This work aims to developing a new technique for pre-processing digital mammographic images in order to improve the performance of computer aided-diagnosis schemes (CAD) and to assist in early detection of breast cancer. The proposed method performs a restoration in mammographic images using in a first step, the Anscombe transform and Wiener filtering to reduce image quantum noise. Subsequently, it was used the inverse modulation transfer function filtering (MTF) considering the imaging system to enhance structures of interest in mammography, such as microcalcifications, which may be an indicative of breast cancer in its early stage. Mammographic images restored by the proposed method were used in the evaluation of a CAD scheme for automatic detection of microcalcifications. The results showed that the performance of the CAD scheme had a significant improvement when restored images were used, even for images of dense breasts, which often results in low detection rate due to low contrast.
22

Estudos sobre personalização da função de transferência relativa à cabeça em sistemas biaurais de reprodução acústica virtual. / Studies about personalization of the head-related transfer function in binaural virtual auditory displays.

Rodriguez Soria, Sergio Gilberto 18 January 2006 (has links)
Este trabalho apresenta diversas propostas associadas ao uso ótimo de funções de transferência relativas à cabeça (HRTFs) em sistemas de reprodução acústica virtual por fones de ouvido. Estas propostas permitem personalizar a HRTF a indivíduos particulares, tomando como base uma combinação da modelagem estrutural e morfológica de HRTFs. Dentro do contexto da modelagem estrutural, o presente trabalho se concentrou no estudo da contribuição do pinna à HRTF. O pinna é a estrutura anatômica responsável pela percepção de elevação. Assim, o primeiro passo foi extrair um conjunto de funções de transferência relativas ao pinna (PRTFs) das HRTFs de uma base de dados. Para tanto, foram usadas diversas técnicas como análise preditiva linear para rastrear as ressonâncias, janelamento para eliminar a influência do torso, funções de autocorrelação e de atraso de grupo para salientar as antirressonâncias, e outros algoritmos para combinar ressonâncias e antirressonâncias em apenas uma magnitude espectral. Usando essa nova base de dados de PRTFs e parâmetros antropométricos propostos mais outros registrados na base de dados, um espaço vetorial correspondente à antropometria do pinna foi mapeado linearmente em um espaço vetorial correspondente às características espectrais da PRTF, calculando-se assim várias transformações lineares para estimação de novas PRTFs fora da base de dados. A estimação atingiu 66% de reconstrução no grupo de treino. O trabalho está orientado à exploração das características espectrais importantes na percepção de elevação, portanto, está limitado ao plano médio do hemisfério frontal, onde não existem diferenças interaurais significativas nem efeitos difrativos da cabeça. Finalmente é proposto um sistema de testes de localização de fonte sonora para validar o modelo. / This work presents several proposals associated with the optimal use of head-related transfer functions (HRTF) in virtual auditory spaces presented via headphones. These proposals lead to personalization of the HRTF to particular individuals, using a combination of the structural and morphological modeling techniques. In the context of structural modeling, this work focuses on modeling the contribution of the pinna to the HRTF. The pinna is the anatomical structure responsible for vertical sound localization. Thus, the first step was to extract a set of pinna-related transfer functions (PRTFs) from HRTFs published in a database. This was accomplished using several techniques like linear prediction analysis for tracking the resonances, windowing for eliminating the torso influence, autocorrelation and group delay functions for emphasizing the notches and other algorithms for combining resonances and notches in only one magnitude response. Using this novel database of PRTFs and a set of proposed anthropometric parameters plus some others registered in the database, a vector space corresponding to pinna anthropometry is linearly mapped into a vector space corresponding to spectral features of the PRTF, being calculated, in this way, several linear transformations for estimation of new PRTFs, outside the database. The estimation attains 66% of reconstruction in the training group. The work focuses on the exploration of spectral characteristics important for elevation perception, therefore, it is limited to the median plane where there are no meaningful interaural differences nor head diffraction effects. Finally, a system for sound localization tests is proposed in order to validate the model.
23

PREVISÃO DE RETORNO DE PNEUS INSERVÍVEIS EM UMA CADEIA DE SUPRIMENTOS DE CICLO FECHADO.

Pereira, Marina Meireles 15 February 2016 (has links)
Made available in DSpace on 2016-08-10T10:40:36Z (GMT). No. of bitstreams: 1 MARINA MEIRELES PEREIRA.pdf: 5021994 bytes, checksum: 7b9170817bc15d6c6c8810e83ac1330e (MD5) Previous issue date: 2016-02-15 / This research aims to apply a prediction model to a tire closed-loop supply chain to estimate the volume returned of scrap tires, through the variables that influence the amount and time that these tires are returned to destination. The methodological approach applied in this research is the modeling by applying the Transfer Function Model. It starts with the analysis that the tire closed-loop supply chain of Goiás and the Federal District is structured and there is a direct relationship between sales of tires with the amount returned. Were adopted as model input variables the amount of tires placed on the market for after-market and the size of the current fleet of these places, representing the amount of tires entered the market for new cars sold. For the output variable was considered the quantity of scrap tires collected and sent for disposal. The data for the survey were collected in the organization s databases adopted as an object of study, IBAMA, DENATRAN, ANIP and AliceWeb considering a period of 54 months. Data were analyzed by the transfer function model and the results showed that the lag time after the tires were entered on the market was around 12 months for all input variables, the return probability of the after-market are greater than the return probability of the tire fleets, and the behavior of the predicted return showed an approximate behavior of the real return with a percentage deviation of 3.4%. Therefore, this study enabled us to identify the variables that influence the return of scrap tires and scale the amount of returned volume tires and the time of this return to facilitate the planning of the tires of closed-loop supply chain. / Esta pesquisa visa aplicar um modelo de previsão a uma cadeia de suprimentos de ciclo fechado de pneus, para estimar o volume de pneus inservíveis retornados, por meio das variáveis que influenciam na quantidade e no tempo que estes pneus retornam para serem destinados. A abordagem metodológica aplicada nessa pesquisa se situa na Modelagem, aplicando o Modelo de Função de Transferência. Parte-se da análise de que a cadeia de suprimentos de ciclo fechado do Estado de Goiás e Distrito Federal está estruturada e que há uma relação direta entre as vendas de pneus com a quantidade retornada. Foram adotadas como variáveis de entrada do modelo a quantidade de pneus inseridos no mercado, pelo mercado de reposição e o tamanho da frota circulante destas localidades, representando a quantidade de pneus inseridos no mercado pelos carros novos vendidos. Para a variável de saída foi considerada a quantidade de pneus inservíveis coletados e encaminhados para destinação final. Os dados utilizados na pesquisa foram coletados em bancos de dados da organização adotada como objeto de estudo, IBAMA, DENATRAN, ANIP e AliceWeb, considerando de um período de 54 meses. Os dados foram analisados pelo modelo de função de transferência e os resultados obtidos mostraram que o tempo de defasagem da entrada de pneus no mercado foi em torno de 12 meses para todas as variáveis de entrada, que as probabilidades de retorno do mercado de reposição são maiores que as probabilidades de retorno dos pneus das frotas e que a previsão de retorno apresentou um comportamento aproximado do comportamento real do retorno com um desvio percentual de 3,4%. Portanto, este estudo possibilitou identificar as variáveis que influenciam no retorno de pneus inservíveis e a dimensionar a quantidade de volume de pneus retornados e o tempo desse retorno para viabilizar o planejamento da cadeia de suprimentos de ciclo fechado de pneus.
24

Estudos sobre personalização da função de transferência relativa à cabeça em sistemas biaurais de reprodução acústica virtual. / Studies about personalization of the head-related transfer function in binaural virtual auditory displays.

Sergio Gilberto Rodriguez Soria 18 January 2006 (has links)
Este trabalho apresenta diversas propostas associadas ao uso ótimo de funções de transferência relativas à cabeça (HRTFs) em sistemas de reprodução acústica virtual por fones de ouvido. Estas propostas permitem personalizar a HRTF a indivíduos particulares, tomando como base uma combinação da modelagem estrutural e morfológica de HRTFs. Dentro do contexto da modelagem estrutural, o presente trabalho se concentrou no estudo da contribuição do pinna à HRTF. O pinna é a estrutura anatômica responsável pela percepção de elevação. Assim, o primeiro passo foi extrair um conjunto de funções de transferência relativas ao pinna (PRTFs) das HRTFs de uma base de dados. Para tanto, foram usadas diversas técnicas como análise preditiva linear para rastrear as ressonâncias, janelamento para eliminar a influência do torso, funções de autocorrelação e de atraso de grupo para salientar as antirressonâncias, e outros algoritmos para combinar ressonâncias e antirressonâncias em apenas uma magnitude espectral. Usando essa nova base de dados de PRTFs e parâmetros antropométricos propostos mais outros registrados na base de dados, um espaço vetorial correspondente à antropometria do pinna foi mapeado linearmente em um espaço vetorial correspondente às características espectrais da PRTF, calculando-se assim várias transformações lineares para estimação de novas PRTFs fora da base de dados. A estimação atingiu 66% de reconstrução no grupo de treino. O trabalho está orientado à exploração das características espectrais importantes na percepção de elevação, portanto, está limitado ao plano médio do hemisfério frontal, onde não existem diferenças interaurais significativas nem efeitos difrativos da cabeça. Finalmente é proposto um sistema de testes de localização de fonte sonora para validar o modelo. / This work presents several proposals associated with the optimal use of head-related transfer functions (HRTF) in virtual auditory spaces presented via headphones. These proposals lead to personalization of the HRTF to particular individuals, using a combination of the structural and morphological modeling techniques. In the context of structural modeling, this work focuses on modeling the contribution of the pinna to the HRTF. The pinna is the anatomical structure responsible for vertical sound localization. Thus, the first step was to extract a set of pinna-related transfer functions (PRTFs) from HRTFs published in a database. This was accomplished using several techniques like linear prediction analysis for tracking the resonances, windowing for eliminating the torso influence, autocorrelation and group delay functions for emphasizing the notches and other algorithms for combining resonances and notches in only one magnitude response. Using this novel database of PRTFs and a set of proposed anthropometric parameters plus some others registered in the database, a vector space corresponding to pinna anthropometry is linearly mapped into a vector space corresponding to spectral features of the PRTF, being calculated, in this way, several linear transformations for estimation of new PRTFs, outside the database. The estimation attains 66% of reconstruction in the training group. The work focuses on the exploration of spectral characteristics important for elevation perception, therefore, it is limited to the median plane where there are no meaningful interaural differences nor head diffraction effects. Finally, a system for sound localization tests is proposed in order to validate the model.
25

Avaliação ponto a ponto de sistemas de imagem radiológica utilizando funções de espalhamento de ponto simuladas. / Evaluating the focal sopt MTF in all radiological field location by computer simulation.

Marques, Paulo Mazzoncini de Azevedo 23 September 1994 (has links)
Esta tese propõe um método de avaliação de sistemas de obtenção de imagem radiológica através das Funções de Transferência simuladas para qualquer região do campo de radiação. Esse processo de simulação reflete as mudanças sofridas pelo ponto focal e, portanto, pela Função de Espalhamento de Ponto (FEP) ao longo do campo. A avaliação utiliza informações obtidas de Funções de Transferência ótica bi-dimensionais calculadas através da aplicação de Transformadas de Fourier sobre as Funções de Espalhamento de Ponto simuladas. O método permite realizar um mapeamento da resposta em freqüências espaciais dos sistemas radio1ógicos para todo o campo de radiação, comparar a nitidez da imagem de sistemas distintos com relação a regiões equivalentes e estudar uma região especifica para prever as distorções que serão inseridas na imagem. / In this work a method of evaluation for the radiological imaging systems performance by simulated transfer functions for any X-ray field region is proposed. The simulation procedures provide information of the changes of the focal spot sizes and, therefore, of the Point Spread Function (PSF) along the field. The evaluation yields the bi-dimensional optical Transfer Functions calculated from Fourier Transformation of the simulated PSFs. This method provides: the spatial frequency response for the entire radiation field of the radiological systems; comparisons of the image sharpness relative to equivalent field regions for different systems; and the study of a singular region in order to predict image distortions.
26

A influência do estoque mundial de açúcar sobre o preço internacional dessa commodity

Lieberg, Vanessa 22 December 2014 (has links)
Submitted by Vanessa Lieberg (vanessa.lieberg@bunge.com) on 2015-01-21T13:18:18Z No. of bitstreams: 1 (A_influência_do_estoque_mundial_de_açúcar_sobre_o_preço_internacional_dessa_commodity_Vanessa_Lieberg).pdf: 2548371 bytes, checksum: cab69de134e04cc1b84969455e32f2a8 (MD5) / Approved for entry into archive by Fabiana da Silva Segura (fabiana.segura@fgv.br) on 2015-01-21T16:08:02Z (GMT) No. of bitstreams: 1 (A_influência_do_estoque_mundial_de_açúcar_sobre_o_preço_internacional_dessa_commodity_Vanessa_Lieberg).pdf: 2548371 bytes, checksum: cab69de134e04cc1b84969455e32f2a8 (MD5) / Made available in DSpace on 2015-01-22T12:33:20Z (GMT). No. of bitstreams: 1 (A_influência_do_estoque_mundial_de_açúcar_sobre_o_preço_internacional_dessa_commodity_Vanessa_Lieberg).pdf: 2548371 bytes, checksum: cab69de134e04cc1b84969455e32f2a8 (MD5) Previous issue date: 2014-12-22 / Global Sugar market has changed considerably since 1970; the dramatic fluctuations in sugar prices have affected the sugar market worldwide. Therefore, new countries such as Brazil, India, China and Thailand start to invest intensively into this market. In the new scenario, Brazil became the main producer of sugar, as well as the main exporter one. The models considered in this study showed the influence of the main sugar producers and the worldwide stocks against the commodity price behaviour. Firstly, the study showed that ending-stocks have a higher impact in the sugar prices comparing to beginning-stocks, in this case, the main countries that contribute for stocks build-up were Brazil and India. Secondly, this study evaluated the impact of the largest sugar producers against the price, the models concluded that Brazil was the most significant country followed by China. Although the study showed Brazil as the main country which impacts stocks and sugar price; it is important to highlight that other countries are also important in the context to identify the main drivers for the supply and demand dynamics in order to evaluate price levels in response of the production and stocks. / O presente estudo visou, principalmente, analisar a influência do estoque mundial de açúcar sobre o preço dessa commodity. O mercado do açúcar mudou consideravelmente após a década de 70 devido à crise do petróleo e a entrada de países em desenvolvimento que passaram a investir intensivamente neste mercado. Países como Brasil, Índia, China e Tailândia ganharam grande representatividade. O maior destaque se tornou o Brasil, sendo este atualmente o maior produtor e exportador de açúcar no mundo. Os principais fatores que tornaram o Brasil um dos líderes deste mercado foram: condições climáticas favoráveis ao cultivo da cana-de-açúcar, ciclo de safra mais longo e em período diferente dos demais países produtores, a flexibilidade em se produzir etanol e açúcar na mesma unidade industrial, incentivos governamentais para o crescimento do setor durante os anos 80 e 90, e assim por diante. Os modelos ajustados para avaliar o efeito do estoque, e da produção dos principais países sobre o preço internacional foram ajustados considerando as propriedades de integração e co-integração das séries utilizadas. O mesmo ocorreu no caso do modelo construído para explicar o a formação de estoques. Modelos alternativos incluindo tendência estocástica foram também ajustados. Primeiramente verificou-se o efeito do estoque inicial e final sobre o preço do açúcar e constatou-se que o estoque no final do ano-safra, o qual representa um excesso de oferta naquele ano, teve um poder explanatório importante sobre o preço da commodity. No caso do estoque do ano anterior, o qual contribui para a oferta do ano-safra em questão, que é determinado também por condições de oferta e demanda daquele ano, o efeito foi menor. Em seguida, procurou analisar o efeito da produção dos principais países que têm potencial para ofertar açúcar no mercado internacional e na formação do estoque mundial. Os resultados mostraram que a produção do Brasil e a da Índia são as mais importantes na definição do estoque mundial de açúcar, seguidas pela da Tailândia. Por fim, ajustou-se um modelo para quantificar o impacto da produção dos maiores produtores de açúcar sobre o seu preço e os resultados revelaram que a produção do Brasil foi a que tem o efeito mais expressivo, seguida pela da China. Concluiu-se, no estudo, que a produção brasileira de açúcar tem uma grande influência sob a ótica da oferta sob o preço, no entanto, outros países também são importantes nesse contexto, como foi o caso da Índia no caso de estoques e a da China no da formação do preço. Além disso, observou-se o efeito do preço internacional de açúcar sobre o mix de produção açúcar/etanol brasileiro e não o contrário.
27

Avaliação ponto a ponto de sistemas de imagem radiológica utilizando funções de espalhamento de ponto simuladas. / Evaluating the focal sopt MTF in all radiological field location by computer simulation.

Paulo Mazzoncini de Azevedo Marques 23 September 1994 (has links)
Esta tese propõe um método de avaliação de sistemas de obtenção de imagem radiológica através das Funções de Transferência simuladas para qualquer região do campo de radiação. Esse processo de simulação reflete as mudanças sofridas pelo ponto focal e, portanto, pela Função de Espalhamento de Ponto (FEP) ao longo do campo. A avaliação utiliza informações obtidas de Funções de Transferência ótica bi-dimensionais calculadas através da aplicação de Transformadas de Fourier sobre as Funções de Espalhamento de Ponto simuladas. O método permite realizar um mapeamento da resposta em freqüências espaciais dos sistemas radio1ógicos para todo o campo de radiação, comparar a nitidez da imagem de sistemas distintos com relação a regiões equivalentes e estudar uma região especifica para prever as distorções que serão inseridas na imagem. / In this work a method of evaluation for the radiological imaging systems performance by simulated transfer functions for any X-ray field region is proposed. The simulation procedures provide information of the changes of the focal spot sizes and, therefore, of the Point Spread Function (PSF) along the field. The evaluation yields the bi-dimensional optical Transfer Functions calculated from Fourier Transformation of the simulated PSFs. This method provides: the spatial frequency response for the entire radiation field of the radiological systems; comparisons of the image sharpness relative to equivalent field regions for different systems; and the study of a singular region in order to predict image distortions.
28

Sistema de avaliação de qualidade de imagem em radiologia digital odontologica / Image quality evaluation system for dental digital radiology

Leão, Tiago Freire Carneiro 13 August 2018 (has links)
Orientador: Eduardo Tavares Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-13T16:14:16Z (GMT). No. of bitstreams: 1 Leao_TiagoFreireCarneiro_M.pdf: 2505362 bytes, checksum: 6d6b07198f62fd7206b28e629cc5ba41 (MD5) Previous issue date: 2009 / Resumo: Novas tecnologias e sistemas de detecção de radiação para a geração de imagens radiográficas odontológicas vêm sendo disponibilizados como alternativa aos filmes radiográficos. Sistemas baseados em tecnologia do tipo PSPL parecem superar algumas das restrições encontradas nos sistemas baseados em tecnologia CCD, tais como volume do detector, cabos de conexão, tamanho limitado da imagem e limitação da latitude. É importante que seja possível comparar sistemas de imagem concorrentes (diferentes tecnologias ou diferentes fabricantes com mesma tecnologia), utilizando ferramentas e protocolos de controle e certificação de qualidade. Foi desenvolvido um pacote computacional e um conjunto de simuladores e foi realizada a análise de dois sistemas comerciais baseados na tecnologia PSPL, de forma a validar o sistema desenvolvido. O programa desenvolvido permite obter e analisar: curva sensitométrica, função de transferência de modulação (MTF), densidade espectral de potência (NPS), quanta equivalente de ruído (NEQ) e eficiência na detecção de quanta (DQE). Os resultados mostraram que o pacote computacional e o conjunto de simuladores permitem realizar o controle de qualidade de sistemas de radiografia digital odontológica de maneira quantitativa e objetiva, facilitando a análise comparativa entre diferentes sistemas comerciais. Palavras-chave: Radiologia digital odontológica, controle de qualidade em radiodiagnóstico, curva sensitométrica, detecção equivalente de quanta, função de transferência de modulação, densidade espectral de ruído, quanta equivalente de ruído. / Abstract: New systems and technologies for radiation detection intended for dental radiology have become available as an alternative to dental radiographic film. Systems based on PSPL technology seems to overcome some of the restrictions of systems based on CCD technology such as the bulky detector, connecting wire, limited image size and limited exposure latitude. It is important that competing imaging systems can be compared (different technologies or different manufacturers of the same technology) by means of quality control tools and quality certification protocols. A software package and a set of specific phantoms were developed and the analyses of two competing PSPL systems were conducted to validate the developed system. The software allows the user to obtain and analyze: the characteristic curve, modulation transfer function (MTF), noise power spectrum (NPS), noise equivalent quanta (NEQ) and detective quantum efficiency (DQE). The results have shown that the developed software and phantom set allow quality control of digital dental radiology systems in a very objective and quantitative way, facilitating comparative analysis of competing commercial systems. Keywords: Digital dental radiology, quality assurance in radiodiagnostic, characteristic curve, detective quantum efficiency, modulation transfer function, noise power spectrum, noise equivalent quanta. / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica
29

Esquema computacional para avaliação automática de parâmetros de qualidade de equipamentos mamográficos / Computational scheme for automatic evaluation of mammography equipments quality parameters

Paulo Domingues de Oliveira Júnior 04 December 2009 (has links)
Este trabalho tem como objetivo o desenvolvimento de um conjunto de procedimentos de avaliação da qualidade de equipamentos mamográficos a partir do processamento de imagens digitais obtidas com a exposição radiográfica de objetos de testes (phantoms) padronizados. O sistema desenvolvido permite a avaliação de diversos parâmetros físicos de qualidade da imagem radiográfica com simplicidade e rapidez, sem abrir mão da precisão, com o mínimo tempo e uso dos equipamentos. Os principais parâmetros avaliados relacionados à qualidade de um sistema de imagem são: a resolução espacial - pela medida da função de transferência de modulação (MTF) - o contraste - medido pela curva sensitométrica e o ruído - pela medida da densidade espectral de ruído (NPS). Dessa forma, o sistema desenvolvido atende às recomendações do ICRU (International Commission on Radiation Units and Measurements), que trata das diretrizes para controle de qualidade de imagens radiográficas em todo o mundo. A partir da medida desses três parâmetros de qualidade é possível também aferir a eficiência de detecção quântica (DQE) do sistema de imagem mamográfica, que permite uma avaliação completa da qualidade da imagem em função da dose recebida pelo paciente. Os resultados obtidos comprovam a possibilidade da aplicação prática do sistema desenvolvido, o qual proporciona uma avaliação completa da qualidade da imagem formada pelo equipamento. Todos os resultados apresentaram baixa estimativa de erro, fundamentados pela análise da incerteza nos processos de medida. Além disso, a avaliação por meio do DQE permitiu realizar uma comparação entre os sistemas mamográficos envolvidos nessa pesquisa. Assim, com base nesses resultados é possível afirmar que o sistema computacional desenvolvido pode desempenhar um papel fundamental na avaliação da qualidade em sistemas de imagens mamográficas. / The aim of this work is to develop a set of procedures for quality assurance of mammographic equipment by the digital image processing of radiographic images of standard test objects (phantoms) acquired by the radiographic equipment. It allows the evaluation of several physical parameters of the radiographic image quality by a simple and quick procedure, with good accuracy, using the equipment the shortest time as possible. The main evaluated parameters related to the quality of an imaging system are: spatial resolution - by measuring the modulation transfer function (MTF) - image contrast - by the measurement of the H&D curve and noise - evaluated by the noise power spectrum (NPS). Thus, it attends the recommendations of the ICRU (International Commission on Radiation Units and Measurements), which deals as the guidelines for quality assurance of radiographic images all over the world. Through these quality parameters is possible to measure the detective quantum efficiency (DQE) of any mammographic system, which allows a full evaluation of the image quality related to the dose absorbed by the patient. The results confirm the possibility of the practical application of the developed system, which provides a full evaluation of the image quality, acquired by the mammographic equipment. All results showed low error estimation, substantiated by the analysis of the uncertainty in measurements procedures. Moreover, the evaluation through the DQE allowed to perform a comparison of mammography systems involved in this research. Thus, based on these results, it is possible to confirm that its system can perform a fundamental part of the quality assurance in mammographic images system.
30

Esquema computacional para avaliação automática de parâmetros de qualidade de equipamentos mamográficos / Computational scheme for automatic evaluation of mammography equipments quality parameters

Oliveira Júnior, Paulo Domingues de 04 December 2009 (has links)
Este trabalho tem como objetivo o desenvolvimento de um conjunto de procedimentos de avaliação da qualidade de equipamentos mamográficos a partir do processamento de imagens digitais obtidas com a exposição radiográfica de objetos de testes (phantoms) padronizados. O sistema desenvolvido permite a avaliação de diversos parâmetros físicos de qualidade da imagem radiográfica com simplicidade e rapidez, sem abrir mão da precisão, com o mínimo tempo e uso dos equipamentos. Os principais parâmetros avaliados relacionados à qualidade de um sistema de imagem são: a resolução espacial - pela medida da função de transferência de modulação (MTF) - o contraste - medido pela curva sensitométrica e o ruído - pela medida da densidade espectral de ruído (NPS). Dessa forma, o sistema desenvolvido atende às recomendações do ICRU (International Commission on Radiation Units and Measurements), que trata das diretrizes para controle de qualidade de imagens radiográficas em todo o mundo. A partir da medida desses três parâmetros de qualidade é possível também aferir a eficiência de detecção quântica (DQE) do sistema de imagem mamográfica, que permite uma avaliação completa da qualidade da imagem em função da dose recebida pelo paciente. Os resultados obtidos comprovam a possibilidade da aplicação prática do sistema desenvolvido, o qual proporciona uma avaliação completa da qualidade da imagem formada pelo equipamento. Todos os resultados apresentaram baixa estimativa de erro, fundamentados pela análise da incerteza nos processos de medida. Além disso, a avaliação por meio do DQE permitiu realizar uma comparação entre os sistemas mamográficos envolvidos nessa pesquisa. Assim, com base nesses resultados é possível afirmar que o sistema computacional desenvolvido pode desempenhar um papel fundamental na avaliação da qualidade em sistemas de imagens mamográficas. / The aim of this work is to develop a set of procedures for quality assurance of mammographic equipment by the digital image processing of radiographic images of standard test objects (phantoms) acquired by the radiographic equipment. It allows the evaluation of several physical parameters of the radiographic image quality by a simple and quick procedure, with good accuracy, using the equipment the shortest time as possible. The main evaluated parameters related to the quality of an imaging system are: spatial resolution - by measuring the modulation transfer function (MTF) - image contrast - by the measurement of the H&D curve and noise - evaluated by the noise power spectrum (NPS). Thus, it attends the recommendations of the ICRU (International Commission on Radiation Units and Measurements), which deals as the guidelines for quality assurance of radiographic images all over the world. Through these quality parameters is possible to measure the detective quantum efficiency (DQE) of any mammographic system, which allows a full evaluation of the image quality related to the dose absorbed by the patient. The results confirm the possibility of the practical application of the developed system, which provides a full evaluation of the image quality, acquired by the mammographic equipment. All results showed low error estimation, substantiated by the analysis of the uncertainty in measurements procedures. Moreover, the evaluation through the DQE allowed to perform a comparison of mammography systems involved in this research. Thus, based on these results, it is possible to confirm that its system can perform a fundamental part of the quality assurance in mammographic images system.

Page generated in 0.1273 seconds