• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 768
  • 29
  • 25
  • 19
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 3
  • 2
  • 1
  • 1
  • Tagged with
  • 868
  • 484
  • 241
  • 166
  • 147
  • 80
  • 74
  • 69
  • 67
  • 65
  • 62
  • 61
  • 60
  • 57
  • 53
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
311

Efeito radiomodificador do resveratrol em cultura de células de rabdomiossarcoma humano (RD) aplicando o teste do cometa / Radiomodifying effect of resveratrol in human rhabdomyosarcoma (RD) cell culture applying the comet assay

Vanessa Danielle Magalhães 13 September 2012 (has links)
O câncer é uma doença de alta incidência e é considerado um problema de saúde pública no mundo todo. O resveratrol é um polifenol de defesa que tem a habilidade de inibir a carcinogênese em múltiplos estágios. Este polifenol é sintetizado por uma grande variedade de plantas em resposta a exposição à radiação ultravioleta (UV) ou também, pelo estresse mecânico produzido pela ação de patógenos, agentes químicos e físicos. As videiras são consideradas as plantas que têm uma capacidade elevada de produzir o resveratrol, portanto suco de uva e vinho, principalmente o vinho tinto são considerados uma boa fonte de resveratrol. Os efeitos protetores exercidos pelo resveratrol promovem efeitos como indução da resposta antiinflamatória, atividade antitumoral, prevenção ou inibição de doenças degenerativas, diminuição da incidência de doenças cardiovasculares, inibição da agregação plaquetária, entre outros. Assim, o resveratrol é considerado um protetor celular. Porém, em concentrações mais elevadas, o resveratrol promove o efeito contrário, sensibilizando as células a algum tipo de efeito, como por exemplo, o efeito da radiação ionizante. O objetivo desse trabalho foi estudar o efeito radiomodificador do resveratrol em cultura de células RD (rabdomiossarcoma humano) aplicando o teste do cometa para avaliação do dano e capacidade de reparo celular. Foi obtida a DL50 das células RD em 403 Gy e o índice de citotoxicidade do resveratrol (IC50%) nas células RD foi de 150 μM. A partir destes resultados foram definidas as doses de radiação gama (50 Gy e 100 Gy) e as concentrações de resveratrol (15 μM 30 μM 60 μM) que foram analisadas no trabalho. Foram evidenciados os efeitos do resveratrol como protetor celular na concentração de 15 μM e seu efeito citotóxico em 60 μM. Com a interação da radiação gama, a concentração de 60 μM não mostrou efeito radiossensibilizador estatisticamente significante. / Cancer is a disease with high incidence and it is considered a worldwide public health problem. Resveratrol is a defense polyphenol that possesses a pharmacological activity of carcinogenisis inhibition in multiple levels. This polyphenol is synthesized naturally by a wide variety of plants according to response of ultraviolet radiation (UV) exposition or according to mechanical stress resulting of pathogens or chemical and physical agents. In vines this substance is found in elevated concentration. Thus, resveratrol is present in grape juice and wines, especially red wine. The protective effects performed by resveratrol during the process of cell damage, produced by oxidative effects of free radicals, promote anti-inflammatory, anti-platelet and anti- carcinogenic activity, prevent or inhibit degenerative diseases, decrease incidence of cardiovascular diseases. Moreover, resveratrol is considered as a cell radioprotector. On the other hand, in some elevated concentrations resveratrol may be considered as a radiosensitizing. The aim of this work was study the radiomodifying effect of resveratrol in human rhabdomyosarcoma (RD) cell culture applying the comet to assess the cellular damage and repair capacity. The RD cells gamma radiation LD50 was 403 Gy and the resveratrol index cytotoxicity (IC50%) was 150 μM. From these results were defined the gamma radiation doses (50 Gy 100 Gy) and the resveratrol concentrations (15 μM 30 μM 60 μM) were used in this study. The 15 μM and 30 μM concentrations showed cell protective and radioprotective effects. The third and higher concentration used in this work shown to be cytotoxic to RD tumor cells; with gamma radiation presence the 60 μM concentration showed no statistically significant radiosensitizing effects.
312

APLICAÇÃO DO MÉTODO DE MONTE CARLO NO ESTUDO DA PADRONIZAÇÃO DE RADIONUCLÍDEOS COM ESQUEMA DE DESINTEGRAÇÃO COMPLEXOS EM SISTEMA DE COINCIDÊNCIAS 4πβ-γ / APPLICATION OF MONTE CARLO METHOD IN STUDY OF THE PADRONIZATION FOR RADIONUCLIDES WITH COMPLEX DISINTEGRATION SCHEME IN 4πβ-γ COINCIDENCE SYSTEM

Mauro Noriaki Takeda 27 October 2006 (has links)
O presente trabalho descreve uma nova metodologia desenvolvida para modelar o comportamento da atividade em sistema de coincidência 4π(PC)β-γ. As eficiências para elétrons no detector proporcional (PC) e para radiação gama no detector de NaI(Tl) foram calculadas utilizando o programa de Monte Carlo MCNP4C. Outro código de Monte Carlo foi desenvolvido para seguir o caminho no esquema de desintegração desde o estado inicial do radionuclídeo precursor, até o estado fundamental do núcleo filho. Cada etapa do esquema de desintegração é selecionada por meio de números aleatórios levando em conta as probabilidades de cada ramo β- ou captura eletrônica, as probabilidades de transição e os coeficientes de conversão interna. Uma vez que o estado final tenha sido atingido é verificado se houve detecção de eventos beta, captura eletrônica ou transições gama, e os eventos para os três espectros, beta, gama e coincidência são contabilizados. A variação da eficiência beta pode ser feita através da simulação de corte na energia detectada ou pela utilização de absorvedores (Collodion). Foram escolhidos para a simulação os radionuclídeos 134Cs, 72Ga que se desintegram por transição β-, 133Ba que se desintegra por captura eletrônica e 35S que é um emissor beta puro. Para este último foi simulando o Método do Traçador. As curvas de extrapolação obtidas por Monte Carlo foram ajustadas pelo Método dos Mínimos Quadrados com os pontos experimentais e comparados com os resultados obtidos pelo Método da Extrapolação Linear. / The present work describe a new methodology for modelling the behaviour of the activity in a 4π(PC)β-γ coincidence system. The detection efficiency for electrons in the proportional counter and gamma radiation in the NaI(Tl) detector was calculated using the Monte Carlo program MCNP4C. Another Monte Carlo code was developed which follows the path in the disintegration scheme from the initial state of the precursor radionuclide, until the ground state of the daughter nucleus. Every step of the disintegration scheme is sorted by random numbers taking into account the probabilities of all β- branches, electronic capture branches, transitions probabilities and internal conversion coefficients. Once the final state was reached beta, electronic capture events and gamma transitions are accounted for the three spectra: beta, gamma and coincidence variation in the beta efficiency was performed simulating energy cut off or use of absorbers (Collodion). The selected radionuclides for simulation were: 134Cs, 72Ga which disintegrate by β- transition, 133Ba which disintegrates by electronic capture and 35S which is a beta pure emitter. For the latter, the Efficiency Tracing technique was simulated. The extrapolation curves obtained by Monte Carlo were filled by the Least Square Method with the experimental points and the results were compared to the Linear Extrapolation method.
313

Comparação ecotoxicológica de princípios ativos de repelentes para invertebrados aquáticos irradiados e não irradiados com radiação gama / Ecotoxicological comparison of active ingredients of repellents for aquatic invertebrates irradiated and non-irradiated with gamma radiation

Giovana Teixeira Gimiliani 25 February 2013 (has links)
Nas últimas décadas, a introdução de produtos de uso diário nos ambientes aquáticos tem sido uma das questões mais discutidas no que se refere ao monitoramento ambiental. Estes produtos não são totalmente removidos pelos processos convencionais de estações de tratamento de esgoto e de água e são continuamente inseridos no ambiente aquático. O Dietiltoluamida, um princípio ativo de repelente de insetos bastante utilizado mundialmente, é um composto ambientalmente persistente e sua toxicidade para alguns organismos aquáticos tem sido comprovada. Em substituição aos produtos sintéticos, a população tem optado em utilizar produtos naturais, sendo cada vez mais comum o uso de repelentes com óleos essenciais de gramíneas. O óleo essencial de capim-limão é um dos mais utilizados nas formulações de cosméticos e de cuidados pessoais. Entretanto, nenhum estudo tem comprovado a sua toxicidade para a biota aquática. Além dos poluentes químicos, os organismos aquáticos podem estar sujeitos à exposição da radiação ionizante proveniente de fontes naturais (background radiation) ou nas proximidades de instalações de usinas nucleares. O presente estudo avaliou a reprodução de invertebrados aquáticos C. silvestrii após a exposição à radiação gama e posteriormente submetidos aos princípios ativos de repelente sintético e natural. Para isso, avaliou-se a citotoxicidade in vitro bem como a ecotoxicidade aguda e crônica dos princípios ativos e o efeito da radiação gama para D. similis e C. silvestrii. Os ensaios com radiação gama foram realizados sob as mesmas condições dos testes de ecotoxicidade, utilizando o irradiador Gamma-Cell com fonte de Co60. De acordo com os resultados obtidos, o óleo essencial apresentou efeito citotóxico igual a 50 mg.L-1 enquanto para o dietiltoluamida, foi de 420 mg.L-1. O efeito tóxico agudo na sobrevivência (CE50) foi encontrado na concentração de 7,2 mg.L-1 e 3,8 mg.L-1 de óleo essencial para D. similis e C. silvestrii, respectivamente. Concentrações de 64,9 e 53,9 mg.L-1 de dietiltoluamida apresentaram efeito agudo na sobrevivência de D. similis e C. silvestrii, respectivamente. 3,4 mg.L-1 foi estabelecida como a concentração de inibição (CI25) de óleo essencial para o dietiltoluamida correspondeu a 16,4 mg.L- 1, ambos para C. silvestrii. As doses letais de radiação gama que causaram efeito agudo na sobrevivência (DL50) foram de 242 Gy para D. similis e 525 Gy para C. silvestrii. A reprodução de C. silvestrii apresentou redução de 25% na dose de 29 Gy. Depois de determinar a ecotoxicidade dos princípios ativos e o efeito da radiação gama, os organismos foram irradiados com dose de 25 Gy, sendo a maior dose que não causou efeito na reprodução de C. silvestrii, e posteriormente foram expostos às mesmas concentrações utilizadas para os princípios ativos. Os resultados mostraram que a reprodução de C. silvestrii não foi afetada significativamente após a irradiação dos organismos testados quando comparada com os organismos não irradiados. / Over the last decades, the introduction of personal care products in aquatic environments has been one of the most discussed issues regarding environmental monitoring. These products are not completely removed by conventional sewage and water treatment processes and are continuously inserted into the aquatic environment. Diethyltoluamide an active ingredient in insect repellents widely used worldwide is an environmentally persistent compound and its toxicity to some aquatic organisms has been proven. In order to replace synthetic products, people have opted to use natural products which made more common the use of repellents with essential oils of grasses. The essential oil of lemongrass is one of the most used in the formulations of cosmetics and personal care. However, no study has proven its toxicity to aquatic biota. In addition to chemical pollutants, aquatic organisms may be subject to exposure of ionizing radiation from natural sources (background radiation) or near nuclear installations. The present study evaluated the reproduction of aquatic invertebrates C. silvestrii after exposure to gamma radiation and further submitted to synthetic and natural repellents. On this account, we evaluated the in vitro cytotoxicity as well as acute and chronic ecotoxicity of the diethyltoluamide and lemongrass oil, as well as the effect of gamma radiation over D. similis and C. silvestrii. Irradiation experiments were carried out under the same conditions as performed for ecotoxicity assays, using a Gamma-Cell irradiator with a Co60 source. According to the results, the essential oil presented a cytotoxic effect at concentrations of 50 mg.L-1 whereas diethyltoluamide at 420 mg.L-1. The acute toxic effect on survival (EC50) was found at concentrations of 7.2 mg.L-1 for essential oil to and 3.8 mg.L-1 for D. similis and C. silvestrii respectively. Concentrations of 64.9 and 53.9 mg.L-1 of diethyltoluamide showed acute effect on survival of D. similis and C. silvestrii, respectively. 3.4 mg.L-1 of essential oil was established as the inhibition concentration (IC25) while for diethyltoluamide such value corresponded to 16.4 mg.L-1, both over C. silvestrii. The lethal doses induced by gamma radiation revealed an acute effect on survival (LD50) at 242 Gy for D. similis and 525 Gy for C. silvestrii. The reproduction C. silvestrii decreased by 25% at a dose of 29 Gy. After determining the ecotoxicity of the active ingredients and the effect of gamma irradiation, the organisms were irradiated at 25 Gy, which corresponded to the higher dose which caused no effect over the reproduction C. silvestrii and were subsequently exposed to the same concentrations used for the active ingredients. The results showed that reproduction C. silvestrii was not significantly affected after irradiation of the assayed organisms when compared to non-irradiated organisms.
314

Desenvolvimento e implantação de um sistema automatizado para adequação do processo de calibração de monitores de radiação gama / Development and implementation of an automated system for adequation of the calibration process for gamma radiation monitors

Iremar Alves da Silva Junior 27 June 2012 (has links)
Esse trabalho foi desenvolvido com a finalidade de melhorar a qualidade dos serviços de calibração e testes de monitores de radiação gama, prestados pelo Laboratório de Calibração de Instrumentos do IPEN, assim como diminuir a dose ocupacional dos técnicos envolvidos no processo de calibração, seguindo os princípios de proteção radiológica. Foi realizado o desenvolvimento e a implantação de um sistema automatizado para o processo de calibração de monitores de radiação gama, constituido por (i) um dispositivo pneumático de troca dos atenuadores e (ii) uma mesa de posicionamento, ambos acionados remotamente por intermédio de um painel de comando. Também fez parte a implantação de um Sistema Irradiador Caesa-Gammatron, que aumentou o intervalo de taxa de kerma no ar, devido sua alta atividade em relação ao sistema atualmente em uso no laboratório de calibração com radiação gama. Para isso, foi necessária a instalação de um dispositivo atenuador controlado remotamente nesse sistema irradiador. Por último foi realizado uma avaliação da redução da dose ocupacional. / This work was developed with the aim of improving the quality of the services of calibration and tests of gamma radiation monitors - provided by the IPEN Laboratory of Instrument Calibration - as well as reducing the occupational dose in technicians involved in the process of calibration, following the principles of radiation protection. In this study it was carried out the development and implementation of a system for adequation of the process of gamma radiation monitors calibration. It is constituted by (i) a pneumatic dispositive to exchange the attenuators and (ii) a positioning table, both actuated through a control panel. System was also implemented. A Caesa-Gammatron Irradiator, which increased the range of the air kerma rates, due to its activity higher than the current system of gamma radiation in use in the calibration laboratory. Hence, it was necessary the installation of remotely controlled in the attenuator dispositive in this irradiator system. Lastly, it was carried out an evaluation in the reduction of the occupational doses.
315

Estudo de soluções de MEH-PPV em dosimetria de radiação gama / Study of MEH-PPV solutions in gamma radiation solutions

Alves, Marcelo Caetano Oliveira 31 July 2008 (has links)
O presente trabalho teve por objetivo o estudo da viabilidade de utilização de soluções de poli[2-metóxi,5-(2-etil-hexiloxi)-p-fenileno vinileno] (MEH-PPV), em diversos solventes tais como CHCl3 (Clorofórmio), diclorometano (CH2Cl2), bromofórmio (CHBr3), dibromometano (CH2Br2), uma mistura de diclorometano (CH2Cl2) e diiodometano (CH2I2) e tolueno (C6H5CH3), como dosímetros de radiações ionizantes. A novidade está no fato de que estes dosímetros têm como principal característica a variação da cor, proporcionando uma medida visual e direta da radiação recebida. Além disso, a sensibilidade dos dosímetros pode ser ajustada por meio da variação da concentração das soluções do polímero. Neste trabalho, foi utilizada a radiação gama, 60Co, para os estudos de viabilidade deste dosímetro. Quando submetidos a certas doses de radiação gama, o polímero estudado sofre alterações em suas propriedades óticas e em sua estrutura molecular. Para avaliar as alterações óticas, foram utilizadas medidas de espectroscopia de absorção UV-Visível (UV-Vis) e fotoluminescência. Também foram avaliadas as alterações na estrutura molecular, como conseqüência da exposição à radiação gama por meio de técnicas como ressonância magnética nuclear (RMN) e cromatrografia de permeação de gel (GPC). Os Resultados obtidos mostraram que a radiação gama, 60Co, promove, de forma indireta, a diminuição do comprimento efetivo da conjugação do polímero, mais provavelmente em decorrência da quebra da cadeia principal do polímero devido às reações com as espécies reativas, possivelmente nos grupamento vinil. Estas quebras resultam em um deslocamento dos picos máximos dos espectros de absorção para regiões de maior energia (blueshift). Estes deslocamentos dependem não somente da dose de irradiação, mas também do solvente utilizado em da concentração da solução. / The present work aims the study of the viability of using solutions of poly[2-methoxy-5-(2\'-ethyl-hexyloxy)-1,4-phenylene vinylene] (MEH-PPV), in several solvents such as chloroform (CHCl3), dichloromethane (CH2Cl2), bromoform (CHBr3), dibromomethane (CH2Br2), a mix of dichloromethane (CH2Cl2) and diiodomethane (CH2I2), and toluene (C6H5CH3) as ionizing radiation dosimeters, gamma, in this case. The novelty is in the fact of the dosimeter main characteristic is color change, allowing a visual and direct received radiation measurement. Besides, the sensibility of the dosimeter can be adjusted by the polymer solution concentration variation. In this work, it was used the gamma radiation, 60Co, for the dosimeter viability studies. When exposed to certain doses of this kind of radiation, the studied polymer suffers changes in its optic properties and in its molecular structure. In order to evaluate the optical changes, UV-VIS absorption and photoluminescence spectroscopy measures were performed. Besides, the molecular structure changes, as a consequence of the exposure to gamma radiation, were evaluated by nuclear magnetic resonance (NMR) and Gel Permeation Chromatography (GPC). The results show that the gamma radiation, 60Co, promotes, indirectly, the decrease of the polymer conjugation length probably due the backbone scission caused by reactions with reactive species, probably in the vinyl side groups. These scissions resulted in a blueshift of the absorption spectra maximum peaks. Theses blueshifts depend on the irradiation dose, the used solvent and the solution concentration.
316

Aplicação da radiação gama na determinação de parâmetros físicos em madeiras / Application of gamma radiation in the determination of physical parameters in woods

Carvalho, Gilberto 11 December 2013 (has links)
Por sua disponibilidade e características diferenciadas, a madeira foi um dos primeiros materiais a ser usado pelos seres humanos, com uma grande multiplicidade de usos, diretos e indiretos. Ainda hoje é uma importante fonte de energia doméstica e industrial, além de ser usada como matéria prima na fabricação de papel e celulose, nas indústrias químicas, moveleira, naval, de artigos esportivos, brinquedos e instrumentos musicais, bem como na construção civil e na distribuição de energia elétrica. A madeira tem sido bastante estudada, sendo do conhecimento dos pesquisadores da área, a influência de vários fatores no desenvolvimento das árvores e por consequência, nas madeiras, como temperatura, latitude, longitude, altitude, insolação, solo e índice pluviométrico, razões pelas quais, quando se trata de madeira, se fala sempre em propriedades médias. A densidade é na opinião da grande maioria dos pesquisadores, a propriedade mais importante da madeira, por manter estreitas relações com propriedades físicas e mecânicas. Há três tipos de densidades, básica, aparente e a verde. Destas, usou-se a densidade aparente, a 12% de umidade e próxima da umidade de equilíbrio com o meio ambiente e a densidade a verde, na simulação no laboratório. Neste trabalho foram utilizadas madeiras de densidades variáveis, de sete espécies diferentes, a saber: freijó, peroba-mica, jequitibá, muiracatiara, cumaru, ipê e sucupira. Para a determinação das densidades pelo método não convencional, um dos objetivos deste trabalho, foi usar os radioisótopos: 241Am, 133Ba, 192Ir, 137Cs e 60Co, um detetor de cintilação de NaI e um espectrômetro multicanal, desenvolvendo-se uma técnica alternativa, rápida e precisa, fato evidenciado pelos resultados obtidos. Os parâmetros nucleares obtidos, como meias espessuras e coeficientes de absorção linear, proporcionaram a escolha do radioisótopo, 137Cs, em relação à energia, atividade, espessuras ótimas de ensaio, resolução e proteção radiológica, para simulação em laboratório da integridade física de postes de madeira e árvores vivas, constituindo os parâmetros nucleares e as simulações em laboratório, os outros importantes objetivos do trabalho. / Due to availability and differentiated features, wood was one of first materials to be used by humans, with a wide variety of applications. Today it is still an important source of domestic and industrial energy, besides to be used as raw material in manufacture of pulp and cellulose, in chemical industry, furniture, naval, sporting goods, toys and musical instruments as well as in construction and distribution of electric energy. Wood has been studied intensively and researchers in the area are aware of the influence of various factors in the development of trees and as consequence, in wood, such as: temperature, latitude, longitude, altitude, sunlight, soil and rainfall, reasons for which when it refers to wood, always it is average properties. The density it is in the opinion of majority of researchers, the most important property of wood, maintaining a close relationship with mechanical and physics properties of wood. There are three types of densities; basic, apparent and green and among these we used the apparent density to 12% of moisture content and green, density of living trees. In this work it was used woods of various densities, of seven different species of trees, namely: ¨freijó¨, ¨peroba-mica¨, ¨jequitibá, muiracatiara, cumaru, ipê and sucupira. For the determination of densities, one of the goals of this work, was to use the radioisotopes: 241Am, 133Ba, 192Ir, 137Cs and 60Co, a NaI scintillation detector and a multichannel spectrometer, developing a non-conventional method, fast and accurate, evidenced by results. The nuclear parameters obtained such as, half value layers and linear attenuation coefficients provided the choice of the best radioisotope, 137Cs, for inspection of electric wooden poles and living trees in the laboratory simulations, are others important goals of this work.
317

Dosimetria de altas doses de raios gama e elétrons com diodos de Si resistentes a danos de radiação / Gamma and electron high dose dosimetry with rad-hard Si diodes

Pascoalino, Kelly Cristina da Silva 28 May 2014 (has links)
Neste trabalho foram avaliadas as principais características dosimétricas de diodos crescidos pelos métodos de Fusão Zonal (FZ) e Czochralski magnético (MCz), resistentes a danos de radiação, quando aplicados em dosimetria de processos de irradiação industrial com elétrons (1,5 MeV) e raios gama (60Co). O sistema dosimétrico proposto baseia-se no registro de valores de correntes elétricas geradas nos diodos devido à passagem da radiação ionizante. A uniformidade de resposta de um lote de dispositivos foi analisada para os diodos FZ do tipo n irradiados com raios gama. Para uma dose de até 5 kGy obteve-se um coeficiente de variação de 1,25% dos valores de corrente elétrica registrados. A queda da sensibilidade dos diodos com o acúmulo de dose (Total Ionizing Dose TID) foi observada, de acordo com o esperado, para ambos os diodos FZ e MCz, sendo mais acentuada para dispositivos do tipo n ou com resistividade menor, quando irradiados com raios gama. Nos procedimentos de irradiação com elétrons foram utilizados dois protótipos de sonda dosimétrica, sendo que um deles foi projetado para evitar a deterioração dos contatos elétricos e da metalização dos diodos, fenômeno observado durante o desenvolvimento do projeto. A queda da sensibilidade dos diodos FZ e MCz pré-irradiados foi de aproximadamente 10% e 40%, respectivamente, durante os procedimentos de irradiação com elétrons para uma dose acumulada total de 1,25 MGy. A influência dos danos causados por esse tipo de radiação nas propriedades elétricas dos diodos FZ e MCz foi avaliada por meio das medições de corrente de fuga e da capacitância em função da tensão de polarização. A corrente de fuga, que aumenta com a dose de radiação acumulada, não contribui significativamente para a formação do sinal de corrente durante a irradiação, uma vez que os diodos são operados no modo fotovoltaico, ou seja, sem tensão de polarização. Para o diodo MCz não foram observadas alterações significativas dos valores de tensão de depleção total, evidenciando sua maior tolerância aos danos induzidos pela radiação, como esperado. Como durante os procedimentos de irradiação com elétrons há uma variação acentuada dos valores de temperatura, a influência deste parâmetro para as medições de corrente elétrica foi avaliada por meio da extrapolação dos valores de corrente de fuga até 35°C. A contribuição da corrente de fuga para a corrente induzida pela radiação, devido ao aumento da temperatura, não ultrapassa 0,1% para os diodos FZ e MCz. A influência do tipo de radiação, elétrons ou raios gama, na pré-dose dos diodos foi avaliada para o dispositivo FZ do tipo n e observou-se que a pré-irradiação com elétrons é mais eficiente no tocante à queda da sensibilidade dos dispositivos. Os resultados apresentados neste trabalho indicam a potencialidade da aplicação dos diodos FZ e MCz como dosímetros em processos de irradiação de rotina com raios gama e elétrons. Vale ressaltar que a vantagem do sistema proposto reside na possibilidade de acompanhamento em tempo real dos processos envolvidos, sobretudo para elétrons, permitindo a monitoração dos parâmetros dos aceleradores, tais como velocidade de esteira e corrente elétrica de feixe. / In this work the main dosimetric characteristics of rad-hard Float Zone (FZ) and magnetic Czochralski (MCz) diodes to electrons (1.5 MeV) and gamma (60Co) radiation are evaluated. The dosimetric system proposed is based on electrical current measurements due to radiation interactions on the devices. The batch response uniformity was studied for the n-type FZ diodes irradiated with gamma rays. The coefficient of variation of the current measurement was about 1.25% at 5 kGy of accumulated dose. A sensitivity decrease with the increase of the accumulated dose (Total Ionizing Dose TID) was observed for both FZ and MCz diodes. For gamma irradiation, these effect is more pronounced for n-type or smaller resistivity diodes. Two types of dosimetric probe were used on the electron irradiation procedures, one of them specially designed to avoid the deterioration of the electrical contacts and the diodes metallization. The sensitivity of the preirradiated FZ and MCz diodes fell about 10% and 40%, respectively, during electron irradiation at 1.25 MGy of accumulated dose. The effect of electron radiation damage on the electrical properties of the diodes was studied by the means of leakage current and capacitance measurements as a function of bias voltage. The leakage current increases with the accumulated dose but does not contributes significantly to the current signal, since the diodes are operated in photovoltaic mode, without bias voltage. For the MCz diode no change in the full depletion voltage was observed, which indicates its higher tolerance to radiation-induced damage, as expected. During electron irradiation the temperature increases and in order to determine its influence for the current signals, the leakage current values were extrapolated up to 35 °C. The contribution does not exceed 0.1% for FZ and MCz diodes. The effect of the radiation type, electrons or gamma rays, on the predose procedures was analyzed for the FZ n-type device and was observed that the electron pre-irradiation is more efficient regarding the sensitivity decrease. The present work indicates the potential application of FZ and MCz diodes as dosimeters in gamma rays and in electron routine irradiation processes. It is worth noting that the proposed system advantage relies on the possibility of real-time monitoring of electron accelerator parameters.
318

Avaliação morfofuncional de pele humana conservada em glicerol e submetida à radiação gama: estudo em camundongos atímicos / Morphofunctional evaluation of human skin preserved in glycerol and exposed to gamma radiation: a study in athymic mice

Bringel, Fabiana de Andrade 27 April 2011 (has links)
Extensas lesões na pele expõem o organismo a uma série de agentes agressores, dificultando a reparação espontânea da pele e muitas vezes levando o paciente a óbito. Nesse caso, se não houver áreas doadoras de autoenxertos, pode se utilizar aloenxertos. Neste tipo de enxerto, os tecidos são processados em Bancos de Tecidos, onde se pode empregar a radiação ionizante como método de esterilização. De acordo com estudos in vitro, a radiação gama, em doses acima de 25 kGy, provoca desestruturação das fibrilas de colágeno I da derme conservada em glicerol na concentração de 85%, reduzindo significativamente a resistência à tração dos tecidos irradiados. Observações clínicas sugerem, ainda, integração mais rápida da derme humana, conservada em glicerol e submetida à radiação ionizante, com os tecidos do receptor, quando comparada à derme somente conservada em glicerol. Para verificar se essas alterações relatadas in vitro, comprometeriam o emprego in vivo, de amostras de pele humana, submetidas à radiação gama, foram realizados transplantes de peles humanas, irradiadas ou não, em camundongos Nude. A pele dos camundongos foi submetida à análise macroscópica, imagens de tomografia de coerência óptica, histologia e ensaios biomecânicos. Foi possível concluir que os enxertos irradiados a 25 kGy promoveram uma contração inicial maior, mas essa alteração não interferiu na dimensão da área final de reparação, ainda, os animais que receberam esses enxertos apresentaram mais rápido fechamento da ferida em comparação com os demais, além disso o emprego de enxertos irradiados (25 e 50 kGy) promoveu a formação de um processo de reparação mais organizado e sem efeitos significantes nas propriedades biomecânicas. / Extensive skin lesions expose the body to damaging agents, which makes spontaneous regeneration difficult and, in many cases, leads patient to death. In such cases, if there are no donating areas for autograft, allografts can be used. In this type of graft, tissue is processed in tissue banks, where it can be subjected to radiosterilization. According to in vitro studies, gamma radiation, in doses higher than 25 kGy, induces alterations in skin preserved in glycerol at 85%, reducing the tensile strength of irradiated tissue. Clinical observation also suggests faster integration of such graft with the receptors tissue. In order to assess if the alterations observed in vitro, would compromise in vivo use, transplants of human tissue, irradiated or not, were performed in Nude mice. The skin of the mice was subjected to macroscopic analysis, optical coherence tomography imaging, histological and biomechanical assays. It was possible to conclude that grafts irradiated with 25 kGy promoted greater initial contraction, without alteration of the final dimensions of the repair area, also displaying a faster closing of the wound. Moreover, the use of irradiated grafts (25 and 50 kGy) enabled the formation of a more organized healing process without significant effects on biomechanical properties.
319

Efeitos da radiação gama na imunogenicidade das ribonucleoproteínas (RNPs) do vírus da raiva e purificação de anticorpos anti-RNPs para diagnóstico / Effects of gamma radiation immunogenicity of ribonucleoprotein (RNPs) of rabies virus and purification of anti-RNPs antibodies for diagnosis

Costa, Ana Elena Boamorte da 23 August 2010 (has links)
A Organização Mundial da Saúde recomenda o teste de Imunofluorescência Direta (IFD) para a realização do Diagnóstico Laboratorial e Avaliação Sorológica da raiva. Como reveladores deste teste, são utilizados conjugados fluorescentes antirribonucleoproteínas (RNPs) do vírus da raiva, produzidos a partir de anticorpos anti-RNPs obtidos da purificação de soros hiperimunes de animais imunizados com RNPs purificadas. Os objetivos deste estudo foram: avaliar os efeitos da radiação gama na imunogenicidade das RNPs e comparar dois métodos cromatográficos de purificação de imunoglobulinas anti-RNPs. Os soros de animais imunizados com RNPs irradiadas e não irradiadas foram avaliados nos testes de Imunfluorescência Indireta e Ensaio Imunoenzimático. A partir dos resultados obtidos pode-se concluir que os animais imunizados com RNPs irradiadas necessitam de um menor número de doses para uma resposta imunológica com alto título de anticorpos. Por meio da IFD verificou-se que o conjugado produzido com anticorpos anti-RNPs irradiadas apresentou especificidade semelhante a do conjugado produzido a partir de anticorpos anti-RNPs não irradiadas, mas com melhor definição das inclusões características do vírus. Os processos de purificação de anticorpos por cromatografia de troca iônica e cromatografia de afinidade foram avaliados utilizando-se os testes de Bradford e eletroforese (SDS-PAGE). Pelos resultados obtidos pode-se concluir que, neste estudo, o processo de purificação que utilizou a cromatografia de afinidade foi o método que apresentou melhor rendimento, menor tempo de execução e obtenção de anticorpos com maior grau de pureza. / The World Health Organization recommends the direct immunofluorescence test for laboratory diagnosis and serological evaluation of rabies. To achieve this test, fluorescent anti-ribonucleoproteins (RNPs) conjugates, produced from purified IgGs of RNP-immunized animals are employed. The aims of the present study were: investigate the effects of gamma radiation on the immunogenicity of RNPs, as well as to compare two chromatographic methodologies for the purification of anti-RNPs immunoglobulins. Sera from animals immunized with either native or irradiated RNPs were compared by direct immunofluorescence and immunoenzymatic assays. Our results indicate that the animals immunized with irradiated antigen requested a lower number of doses to reach high antibody titers. The immunofluorescence assays indicated that the conjugates produced with the anti-irradiated RNPs IgGs showed similar specificity to its anti-native counterpart, but with a higher definition of the virus inclusions. The purification methods were compared by Bradford and electrophoresis assays. According to the results, we concluded that the affinity-based process resulted in higher yields, lower execution time, and higher purity of the antibodies.
320

ESPECTROSCOPIA GAMA DO 100Rh / GAMMA SPECTROSCOPY OF 100Rh.

Kenchian, Garabed 17 November 1995 (has links)
O esquema de decaimento beta do 100.ANTPOT Rh foi estudado a partir de medidas de espectroscopia gama simples e coincidência gama-gama. Foram observadas e atribuídas ao decaimento beta do 100.ANTPOT Rh 132 transições gama, das quais 68 pela primeira vez. Um número de 32 estados excitados do 100.ANTPOT Rh foram observados sendo que os de energia 2512 keV, 2536 keV, 2543 keV, 2569 keV, 2666 keV, 2745 keV, 2774 keV, 2801 keV e 3072 keV pela primeira vez a partir do decaimento do 100.ANTPOT Rh. Os valores de spin e paridade de vários estados foram propostos com base nas transições observadas nos valores de log(ft) obtidos e nas informações de trabalho anteriores. A meia-vida do decaimento do 100.ANTPOT Rh também foi medida e o valor obtido foi de 20,2(1) h. Um tratamento estatístico levando em conta a covariância foi utilizado no cálculo das energias das transições gama e dos níveis, das intensidades de transição gama e de alimentação beta. Os estados excitados experimentais para o 100.ANTPOT Rh foram comparados com os obtidos do modelo de bósons interatuantes. Observou-se que este modelo, no limite algébrico SU(5) (correspondendo a um vibrador do modelo geométrico) com a inclusão da interação de 3 bósons (relacionada com deformação triaxial), produz um esquema de níveis bastante compatível com o esquema experimental. / The beta decay scheme of 100.ANTPOT Rh has been studied through simple gamma spectroscopy and gamma-gamma spectroscopy. With these two measurements, 132 gamma transitions have been observed and scribed to the 100.ANTPOT Rh decay, 68 of them for the first time. A number of 32 excited states of 100.ANTPOT Rh have been observed and some of them for the first time in the beta decay of 100.ANTPOT Rh (2512 keV, 2536 keV, 2543 keV, 2569 keV, 2666 keV, 2745 keV, 2774 keV, 2801 keV, and 3072 keV). A 20.2h half lofe for the beta decay of 100.ANTPOT Rh has been measured and spin and parity values for several states have been proposed, taking into account the observed transitions, the calculated log(ft) values and the beta intensities. A covariant statistical treatment has been used to calculate gamma transitions energies and intensities, level energies and beta feeding intensities. The experimental excited states of 100.ANTPOT Rh have been compared with those obtained from the interacting boson model. The algebraic SU(5) limit of this model (that correspond to an oscillator in the geometrical model), with the inclusion of 3 boson interaction (related with triaxial deformation), produces a level scheme in good agreement with experimental data.

Page generated in 0.0385 seconds