Spelling suggestions: "subject:"geração distribuídas"" "subject:"geração distribuídos""
201 |
Um algoritmo de proteção adaptativa para sistemas de distribuição com inserção de geração distribuída. / An adaptive protection algorithm for distribution systems with distributed generation insertionNASCIMENTO, Jamile Pinheiro. 20 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-20T22:58:46Z
No. of bitstreams: 1
JAMILE PINHEIRO NASCIMENTO - DISSERTAÇÃO PPGEE 2014..pdf: 2146495 bytes, checksum: e397e112357d55c0badad1a62f5324cf (MD5) / Made available in DSpace on 2018-04-20T22:58:46Z (GMT). No. of bitstreams: 1
JAMILE PINHEIRO NASCIMENTO - DISSERTAÇÃO PPGEE 2014..pdf: 2146495 bytes, checksum: e397e112357d55c0badad1a62f5324cf (MD5)
Previous issue date: 2014-08 / Um algoritmo de proteção adaptativa para solucionar o problema da proteção de sistemas com geração distribuída é proposto. O algoritmo modifica as configurações dos relés de forma on-line, utilizando como informação de entrada, os estados dos disjuntores. Ao final, constatou-se que mesmo com a entrada ou saída dos geradores distribuídos, o sistema de distribuição continuou a ser protegido. Para validar o algoritmo utilizou-se um sistema-teste do IEEE e o Real Time Digital Simulator (RTDS). / An adaptive protection algorithm to solve protecting systems with distributed generation problem is proposed. The algorithm modifies relays settings on on-line form, using circuit breakers state as input information. At the end, it was found that even with the input or output of distributed generators, distribution system continued to be protected. To validate the algorithm it was used an IEEE test system and the Real Time Digital Simulator (RTDS).
|
202 |
Distorções harmônicas produzidas por inversores de geração distribuída fotovoltaica em condição de ressonância paralela /Fortes, Rárison Roberto Acácio January 2016 (has links)
Orientador: Luís Carlos Origa de Oliveira / Resumo: Como os sistemas de energia têm sido tradicionalmente projetados para produção centralizada, a penetração de sistemas de geração distribuída na rede tem causado mudança nesse perfil, criando novos desafios operacionais que se fazem importantes para a reestruturação dos sistemas tradicionais. No entanto, este novo cenário do sistema elétrico, introduzido pela resolução 482/2012 da Agência Nacional de Energia Elétrica – ANEEL, trouxe às distribuidoras de energia um novo panorama para as atividades de operação e manutenção de suas redes e ativos, principalmente devido à bidirecionalidade do fluxo de potência na rede, originado pela conexão de sistemas de geração distribuída. Os impactos técnicos devem ser previstos e analisados, sobretudo em redes de distribuição, para garantir os padrões mínimos de qualidade da energia no ponto de consumo e evitar o comprometimento das cargas alimentadas. Dentre os impactos, destaca-se o efeito sobre os bancos de capacitores devido à injeção de distorções harmônica produzida pelos inversores de sistemas fotovoltaicos, que sob certas condições, produzem conteúdo harmônico com nível acima do limite normatizado, podendo excitar uma condição prévia de ressonância no barramento. Neste contexto, esta dissertação tem como principal objetivo analisar o comportamento do sistema elétrico em condição de ressonância paralela e avaliar o grau de comprometimento dos bancos de capacitores instalados no sistema de distribuição com presença de frequências harmô... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: As energy systems have been traditionally projected for centralized production, the penetration of distributed generation systems have caused a change in this profile, creating new operational challenges that are important for traditional systems restructuring. However, this new electrical system scenario, introduced by resolution 482/2012 of Brazilian Electricity Regulatory Agency – ANEEL, brought to energy distributors a new view to the operational and maintenance activities of their nets and actives, specially due to the net power flow bidirectionality, created by the distributed generation systems connection. Technical impacts must be estimated and analyzed, specially in distribution nets, to ensure minimum energy quality standards in the consumption point and avoid fed charges commitment. Among the impacts stands out the capacitor bench effects due to harmonic distortions injection produced by photovoltaic systems inverters, that under some conditions, produce harmonic content over the regulated limit, being able to excite a preview condition of resonance in the bus. In this context, this essay has the main objective to analyze the electrical system behavior in parallel resonance condition and evaluate the degree of commitment of the capacitor bench installed in the distribution system with harmonic frequencies and suggest technical routines to avoid the contingent operation. / Mestre
|
203 |
Desenvolvimento de um sistema de proteção e metodologia para localização de faltas em sistemas de distribuição /Chaves, Roberto Cesar Pessoa. January 2016 (has links)
Orientador: Fábio Bertequini Leão / Resumo: O sistema de proteção tradicional de sistemas de distribuição predominantemente utiliza relés de sobrecorrente alocados na subestação e religadores automáticos ao longo dos alimentadores principais coordenados com fusíveis em ramais laterais. A inserção de GD (Geração Distribuída) na rede de distribuição pode causar diversos impactos do ponto de vista da proteção do sistema. Um dos impactos mais expressivos é a perda de coordenação dos dispositivos tradicionalmente empregados, devido a inserção da GD possibilitar fluxos de potência bidirecionais na rede. Portanto, neste trabalho é proposta uma solução para proteção e monitoramento da rede de distribuição considerando a inserção de fontes dispersas de energia. O sistema proposto é baseado na separação da rede de distribuição em zonas de proteção de acordo com a possibilidade de ilhamento da GD. Para o monitoramento da rede são empregados sensores indicadores de falta. Um método denominado Método de Degrau de Correntes (MDC) é proposto para identificação e localização de faltas a partir dos dados de monitoramento da rede em tempo real. Uma estratégia de restauração é proposta baseada nos resultados obtidos pelo MDC. Para os estudos, utilizou-se do software de simulação de Sistemas Elétricos de Potência DIgSILENT Power Factory 14.0, empregado para análise de fluxo de potência e verificação de estabilidade nas situações pós-falta. O software MATLAB (MATrix LABoratory) é empregado para o desenvolvimento do algoritmo e metodologia ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The traditional protection system uses predominantly overcurrent relays allocated in substation and automatic reclosers along the main feeders coordinated with fuses in side branches. The penetration of GD (Distributed Generators) in distribution systems can cause different impacts in terms of system protection. One of the most significant impacts is the loss of coordination of the protection devices traditionally employed due to insertion of GD, which allows bidirectional power flows on the network. Therefore, this work proposes a solution for protection and monitoring the distribution network considering the insertion of dispersed energy resources. The proposed system is based on the separation of the distribution network in protection zones in accordance with the possibility of islanding of GD. For network monitoring fault indicators sensors are employed. A method called Currents Step Method (MDC) is proposed to identify and locate faults based on the network monitoring data in real time. A restoration strategy is proposed based on the results obtained by the MDC. For the studies, the DIgSILENT Power Factory 14.0 was employed to carry out power flow and stability analysis. The MATLAB (Matrix Laboratory) software was also used to develop the algorithm and methodology of identification, fault location and isolation of the distribution network using the data provided by the DIgSILENT. Regarding the results, it was noticed that the algorithm has a high reliability for the mos... (Complete abstract click electronic access below) / Mestre
|
204 |
Estratégia de controle para a operação ilhada autônoma de uma unidade eólica de geração associada a banco de bateriasDranka, Géremi Gilson 12 December 2014 (has links)
A inserção e a expansão da geração distribuída (GD) trazem desafios intrínsecos
relacionados, sobretudo, a confiabilidade e operação do sistema elétrico de potência
(SEP), o que resulta em uma mudança de paradigma imposta aos sistemas de
distribuição de energia. Dentre os desafios e oportunidades associados à geração
distribuída, destaca-se a operação ilhada dos sistemas de distribuição e
microrredes. Nesse contexto, esse trabalho propõe estratégias operacionais e de
controle para viabilizar a operação de sistema eólicos. O controle proposto baseia-se
em uma malha de controle suplementar, adicionada à malha de controle de
velocidade da unidade eólica. A malha de controle proposta consiste em uma quebra
de paradigma para o controle da tensão no barramento CC, pois nos sistemas
tradicionais essa tensão é normalmente controlada apenas pelo banco de baterias.
Através do controle suplementar proposto, torna-se possível reduzir o número e a
duração de atuações do banco de baterias, aumentando sua vida útil. Propõe-se
ainda, como contribuição, uma metodologia para o dimensionamento mínimo do
sistema de armazenamento de energia baseado em banco de baterias para permitir
a operação ilhada autônoma de sistemas eólicos. Esse dimensionamento considera
um degrau de carga máximo que deverá ser atendido pelo sistema. Por fim, as
estratégias operacionais e de controle propostas em conjunto com o sistema de
armazenamento de energia são avaliadas e validadas por meio de análises
matemáticas e simulações no domínio do tempo utilizando o sistema proposto. Os
resultados obtidos demonstraram que o controle proposto permitiu a operação
autônoma de um sistema eólico baseado em gerador síncrono com conversor
estático completo. / The insertion and expansion of distributed generation bring about intrinsic
challenges, especially concerning to the reliability and operation of the electric power
system, which results in a paradigm shift imposed on power distribution systems.
Among the challenges and opportunities associated to distributed generation, the
islanded operation of distribution systems and microgrids has grown considerably. In
this context, this paper proposes operational and control strategies to properly allow
the operation of a wind generation system. The proposed control is based on a
supplementary control loop, added to the speed control loop of the wind turbine. The
proposed control loop consists of a paradigm shift to control the DC-link voltage,
since in traditional systems the DC-link voltage is usually controlled only by the
BESS. The proposed supplementary control loop reduces the number and duration
of the BESS actuations. Furthermore, the proposed strategy can contribute to
enhance the reliability and the life cycle of the energy storage device. This work also
proposes a new methodology for minimum sizing of battery energy storage systems
to allow the islanded operation of wind power systems. The methodology considers a
maximum load step to be supplied by the system. Finally, the proposed control and
operational strategies with the BESS are evaluated and validated throughout
mathematical analysis and simulation in the time domain using the proposed system.
The proposed control strategy was effective in regulating the DC-link voltage,
allowing the islanded operation of a wind power system based on synchronous
generator with full-size power converters.
|
205 |
Conversor elevador de tensão flyback intercalado aplicado à conexão entre fontes de energias renováveis e um microgrid CCScortegagna, Renato Gregolon 06 July 2015 (has links)
Com o crescente aumento da demanda de energia elétrica em nível mundial, há também um crescimento dos desafios de integrar diferentes formas de geração de energia com os microgrids CC. As fontes de geração distribuída constituídas de fontes renováveis tais como solar, pequenas centrais eólicas, células de combustível, entre outras, normalmente produzem baixas tensões elétricas, cabendo a um conversor propiciar o ganho de tensão que possibilite `a sua conexão com o sistema. Neste trabalho, é apresentado o estudo do conversor flyback intercalado com foco na análise matemática e na implementação do indutor acoplado flyback visando a diminuição de perdas. Inicialmente, é feita uma revisão dos conversores CC−CC que possuem características de aplicação similares à proposta desse trabalho. A partir da revisão, são apresentadas as vantagens e desvantagens da utilização de conversores isolados e as suas limitações quanto à potência e aos modos de operação. Uma análise detalhada utilizando o método do transformador PWM é realizada para a determinação do ganho de tensão e do rendimento do conversor flyback intercalado operando no modo de condução descontínua. Os procedimentos de projeto do indutor acoplado e dos componentes do circuito eletrônico são apresentados e detalhados. Os circuitos snubbers regenerativo e dissipativo (RCD) são projetados e implementados para a comparação dos resultados. Um conversor flyback intercalado com potencia nominal de 500Wfoi simulado e implementado, sendo que resultados de simulação e experimentais são apresentados, comparados e discutidos. Ao final do trabalho, um mainframe CC é proposto e simulado, fazendo a integração e o controle de dois conversores CC−CC operando em paralelo. / The power demand worldwide is increasing and there is also a growing challenges of integrating different ways of power generation with the DC microgrids. The sources of distributed generation formed by renewable sources such as solar, small wind power plants, fuel cells, among others, usually produce low voltages, leaving the converter provide the voltage gain that enables to their connection to the system. This work presents the study of interleaved flyback converter with focus on mathematical analysis and implementation of the flyback coupled inductor in order to minimize losses. Initially, it made a review of DC-DC converters that have similar application characteristics to the proposal of this work. From the review, the advantages and disadvantages of using isolated converters and their limitations on the power and operating modes are presented. A detailed analysis using the PWM transformer method is performed for determining the voltage gain and the interleaved flyback converter efficiency operating in discontinuous conduction mode. Coupled inductor design procedures and electronic circuit components are presented and detailed. The regenerative and dissipative (RCD) snubbers circuits are designed and implemented to compare the results. A interleaved flyback converter with nominal power of 500 W was simulated and implemented, and simulation and experimental results are presented, compared and discussed. At the end of the work, a DC mainframe is proposed and simulated, making the integration and control of two DC-DC converters operating in parallel.
|
206 |
Controladores auxiliares de frequência para o restabelecimento de microrredes ilhadas com alto nível de inserção de geração eólica / Auxiliary frequency controllers for the black start of islanded microgrids with high wind energy penetrationBordignon, Andrei 02 June 2017 (has links)
CAPES / A difusão da geração distribuída e das microrredes, bem como a crescente expansão do uso de energias renováveis, como a eólica, trazem desafios e oportunidades relacionados à operação e controle de sistemas elétricos. Em sistemas sujeitos à operação ilhada, a capacidade de restabelecimento é fundamental para que o suprimento de energia seja retomado após a ocorrência de um desligamento. Esta tarefa pode ser de difícil execução, uma vez que desbalanços de potência significativos podem ocorrer, decorrentes da energização da rede e de variações na disponibilidade de energia primária. Neste contexto, o presente trabalho propõe a adoção de estratégias operacionais e de controle que possibilitem a execução do processo de restabelecimento em microrredes híbridas eólico-diesel com alto nível de inserção de geração eólica, sem a adoção de sistemas de armazenamento de energia. A proposta é baseada em duas malhas de controle suplementares para uma unidade eólica de conversor pleno, que habilita a unidade eólica para contribuir com a regulação de frequência durante o restabelecimento da microrrede. Os dois controladores propostos são excitados pelo erro de frequência do sistema e atuam somente quando as cargas do sistema são energizadas. Um dos controladores suplementares tem o objetivo de extrair energia cinética da turbina eólica, através da atuação na referência de velocidade da turbina nas malhas de controle do conversor do lado do gerador. O segundo controlador suplementar é projetado para extrair temporariamente energia elétrica armazenada no barramento CC da unidade eólica, por meio de um deslocamento temporário da referência de tensão do barramento CC nas malhas de controle do conversor do lado da rede. A energia extraída da turbina eólica e do barramento CC é transmitida ao sistema para mitigar o desbalanço de potência causado por um incremento de carga. Assim, as estratégias de controle propostas previnem afundamentos excessivos de frequência durante o restabelecimento de sistemas com baixa inércia. Para o projeto dos controladores propostos, uma técnica de otimização baseada em algoritmos genéticos foi utilizada. O desempenho do sistema é comparado em dois diferentes modos de operação, gerador diesel operando em modo Vf e unidade eólica operando em modo Vf. Resultados obtidos por meio de simulações não lineares no domínio do tempo demostram a efetividade das estratégias propostas. / The diffusion of distributed generation and microgrids, as well as the growing expansion of renewable energy, like wind power, bring challenges and opportunities related to the operation and control of electrical power systems. In systems exposed to islanded operation, the black start capability is fundamental to restore the energy supply after the occurrence of a blackout. The black start is usually a difficult operational event, since significant power unbalances may occur in the system. The present work proposes operational and control strategies that make possible the black start of wind-diesel microgrids with high penetration level of wind generation, without the adoption of energy storage systems. The proposed control approach is based on two supplementary control loops for a fully rated converter wind turbine, which enable the wind unit to contribute to the frequency regulation during the black start of a stand-alone system. Both the proposed controllers employ the system frequency error as input signal and act only when the system loads are energized. One of the supplementary controllers seeks to extract kinetic energy from the wind turbine, by modifying the speed reference of the wind turbine in the typical control loop of the rotor-side converter. The second supplementary controller is designed to temporarily extract electrical energy from the DC-link capacitor, by acting in the reference of the DC-link voltage in the typical control loop of the grid-side converter. The energy extracted from the wind turbine and DC-link capacitor is injected into the grid to mitigate the power unbalance caused by the load energization. Thus, the proposed control strategies prevent excessive frequency drops during the load energization of low inertia stand-alone systems in restoration procedures. The design of the proposed controllers was performed by a genetic algorithm optimization technique. The performance of the system is compared in two different operation modes, diesel generator operating in Vf control mode and wind generation unit operating in Vf control mode. Results obtained by nonlinear time domain simulations demonstrate the effectiveness of the proposed control approach.
|
207 |
Conversor elevador de tensão flyback intercalado aplicado à conexão entre fontes de energias renováveis e um microgrid CCScortegagna, Renato Gregolon 06 July 2015 (has links)
Com o crescente aumento da demanda de energia elétrica em nível mundial, há também um crescimento dos desafios de integrar diferentes formas de geração de energia com os microgrids CC. As fontes de geração distribuída constituídas de fontes renováveis tais como solar, pequenas centrais eólicas, células de combustível, entre outras, normalmente produzem baixas tensões elétricas, cabendo a um conversor propiciar o ganho de tensão que possibilite `a sua conexão com o sistema. Neste trabalho, é apresentado o estudo do conversor flyback intercalado com foco na análise matemática e na implementação do indutor acoplado flyback visando a diminuição de perdas. Inicialmente, é feita uma revisão dos conversores CC−CC que possuem características de aplicação similares à proposta desse trabalho. A partir da revisão, são apresentadas as vantagens e desvantagens da utilização de conversores isolados e as suas limitações quanto à potência e aos modos de operação. Uma análise detalhada utilizando o método do transformador PWM é realizada para a determinação do ganho de tensão e do rendimento do conversor flyback intercalado operando no modo de condução descontínua. Os procedimentos de projeto do indutor acoplado e dos componentes do circuito eletrônico são apresentados e detalhados. Os circuitos snubbers regenerativo e dissipativo (RCD) são projetados e implementados para a comparação dos resultados. Um conversor flyback intercalado com potencia nominal de 500Wfoi simulado e implementado, sendo que resultados de simulação e experimentais são apresentados, comparados e discutidos. Ao final do trabalho, um mainframe CC é proposto e simulado, fazendo a integração e o controle de dois conversores CC−CC operando em paralelo. / The power demand worldwide is increasing and there is also a growing challenges of integrating different ways of power generation with the DC microgrids. The sources of distributed generation formed by renewable sources such as solar, small wind power plants, fuel cells, among others, usually produce low voltages, leaving the converter provide the voltage gain that enables to their connection to the system. This work presents the study of interleaved flyback converter with focus on mathematical analysis and implementation of the flyback coupled inductor in order to minimize losses. Initially, it made a review of DC-DC converters that have similar application characteristics to the proposal of this work. From the review, the advantages and disadvantages of using isolated converters and their limitations on the power and operating modes are presented. A detailed analysis using the PWM transformer method is performed for determining the voltage gain and the interleaved flyback converter efficiency operating in discontinuous conduction mode. Coupled inductor design procedures and electronic circuit components are presented and detailed. The regenerative and dissipative (RCD) snubbers circuits are designed and implemented to compare the results. A interleaved flyback converter with nominal power of 500 W was simulated and implemented, and simulation and experimental results are presented, compared and discussed. At the end of the work, a DC mainframe is proposed and simulated, making the integration and control of two DC-DC converters operating in parallel.
|
208 |
Controladores auxiliares de frequência para o restabelecimento de microrredes ilhadas com alto nível de inserção de geração eólica / Auxiliary frequency controllers for the black start of islanded microgrids with high wind energy penetrationBordignon, Andrei 02 June 2017 (has links)
CAPES / A difusão da geração distribuída e das microrredes, bem como a crescente expansão do uso de energias renováveis, como a eólica, trazem desafios e oportunidades relacionados à operação e controle de sistemas elétricos. Em sistemas sujeitos à operação ilhada, a capacidade de restabelecimento é fundamental para que o suprimento de energia seja retomado após a ocorrência de um desligamento. Esta tarefa pode ser de difícil execução, uma vez que desbalanços de potência significativos podem ocorrer, decorrentes da energização da rede e de variações na disponibilidade de energia primária. Neste contexto, o presente trabalho propõe a adoção de estratégias operacionais e de controle que possibilitem a execução do processo de restabelecimento em microrredes híbridas eólico-diesel com alto nível de inserção de geração eólica, sem a adoção de sistemas de armazenamento de energia. A proposta é baseada em duas malhas de controle suplementares para uma unidade eólica de conversor pleno, que habilita a unidade eólica para contribuir com a regulação de frequência durante o restabelecimento da microrrede. Os dois controladores propostos são excitados pelo erro de frequência do sistema e atuam somente quando as cargas do sistema são energizadas. Um dos controladores suplementares tem o objetivo de extrair energia cinética da turbina eólica, através da atuação na referência de velocidade da turbina nas malhas de controle do conversor do lado do gerador. O segundo controlador suplementar é projetado para extrair temporariamente energia elétrica armazenada no barramento CC da unidade eólica, por meio de um deslocamento temporário da referência de tensão do barramento CC nas malhas de controle do conversor do lado da rede. A energia extraída da turbina eólica e do barramento CC é transmitida ao sistema para mitigar o desbalanço de potência causado por um incremento de carga. Assim, as estratégias de controle propostas previnem afundamentos excessivos de frequência durante o restabelecimento de sistemas com baixa inércia. Para o projeto dos controladores propostos, uma técnica de otimização baseada em algoritmos genéticos foi utilizada. O desempenho do sistema é comparado em dois diferentes modos de operação, gerador diesel operando em modo Vf e unidade eólica operando em modo Vf. Resultados obtidos por meio de simulações não lineares no domínio do tempo demostram a efetividade das estratégias propostas. / The diffusion of distributed generation and microgrids, as well as the growing expansion of renewable energy, like wind power, bring challenges and opportunities related to the operation and control of electrical power systems. In systems exposed to islanded operation, the black start capability is fundamental to restore the energy supply after the occurrence of a blackout. The black start is usually a difficult operational event, since significant power unbalances may occur in the system. The present work proposes operational and control strategies that make possible the black start of wind-diesel microgrids with high penetration level of wind generation, without the adoption of energy storage systems. The proposed control approach is based on two supplementary control loops for a fully rated converter wind turbine, which enable the wind unit to contribute to the frequency regulation during the black start of a stand-alone system. Both the proposed controllers employ the system frequency error as input signal and act only when the system loads are energized. One of the supplementary controllers seeks to extract kinetic energy from the wind turbine, by modifying the speed reference of the wind turbine in the typical control loop of the rotor-side converter. The second supplementary controller is designed to temporarily extract electrical energy from the DC-link capacitor, by acting in the reference of the DC-link voltage in the typical control loop of the grid-side converter. The energy extracted from the wind turbine and DC-link capacitor is injected into the grid to mitigate the power unbalance caused by the load energization. Thus, the proposed control strategies prevent excessive frequency drops during the load energization of low inertia stand-alone systems in restoration procedures. The design of the proposed controllers was performed by a genetic algorithm optimization technique. The performance of the system is compared in two different operation modes, diesel generator operating in Vf control mode and wind generation unit operating in Vf control mode. Results obtained by nonlinear time domain simulations demonstrate the effectiveness of the proposed control approach.
|
209 |
Geração distribuída: legislação brasileira, perspectivas e estudos de casos via ATP / Distributed generation: brazilian law, prospects and case studies via ATPRezende, Jaqueline Oliveira 04 February 2015 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The constant concern to meet the growing demand for electricity has provided several researches in different areas in order to obtain new forms of power generation. In this context, distributed generation has emerged as a promising source of electricity located closely to consumer. Therefore, this work has as main objective to analyze the regulatory incentives for the use of distributed generation in Brazil, clearly display the current national legislation of this sector, report the future prospects to regulate this type of generation and assess the contributions of a distributed generation unit connected to a distribution feeder. Initially, it are considered the various descriptions and definitions for distributed generation, as well as concepts and differences between centralized and distributed generation. For a better understanding of distributed generation it is also presented the most prominent advantages and disadvantages of using such generation and the main energy sources that can be used in distributed generation whether renewable or non-renewable. In sequence, Brazilian laws that have contributed to promote the use of distributed generation in this country are presented in detail. It is also addressed the technical standards of the leading electricity distributors in Brazil, since the preparation of such regulations is determined by law. Comparisons are also made between national and foreign standards and presented the future prospects for the Brazilian law of this sector. To evaluate the effects of distributed generation in a distribution feeder, simulations of common disturbances are performed in an electric power system. They are: three-phase short-circuit, phase-to-ground short-circuit, islanding of part of the electrical system and load increase. All case studies are prepared and run with ATP software. To help the analysis, the distributed generator is first disconnected and after connected to the system. / A preocupação constante em atender à crescente demanda de energia elétrica tem proporcionado várias pesquisas em diversas áreas com a finalidade de obtenção de novas formas de geração de energia elétrica. Neste contexto, a geração distribuída tem se apresentado como uma fonte promissora de eletricidade localizada próxima do consumidor. Dessa forma, este trabalho possui como principal objetivo analisar os incentivos regulatórios para a utilização da geração distribuída no Brasil, apresentar de forma clara a legislação nacional vigente desse setor, relatar as perspectivas futuras para regular esse tipo de geração e avaliar as contribuições de uma unidade de geração distribuída conectada a um alimentador de distribuição.
Inicialmente, são abordadas as várias denominações e definições destinadas a geração distribuída, assim como conceitos e diferenças entre geração centralizada e geração distribuída. Para a melhor compreensão da geração distribuída também são apresentadas as vantagens e desvantagens de maior destaque na utilização desse tipo de geração e as principais fontes energéticas, renováveis ou não, que podem ser empregadas na geração distribuída.
Em sequência, são apresentadas detalhadamente as legislações brasileiras que têm contribuído para incentivar a utilização da geração distribuída no país. São abordadas as normas técnicas das principais distribuidoras de energia elétrica do Brasil, desde que a elaboração dessas foi determinada por lei. Comparações são também realizadas entre as normas nacionais e estrangeiras e apresentadas as perspectivas futuras para a legislação brasileira desse setor.
Com a finalidade de avaliar os efeitos da geração distribuída em um alimentador de distribuição, são realizadas simulações de distúrbios comuns no sistema elétrico de potência, como: curto-circuito trifásico, curto-circuito fase terra sólido, ilhamento de parte do sistema elétrico e aumento de carga. Todos os estudos de casos são preparados e processados com o software ATP. Para auxiliar na análise, o gerador distribuído é primeiramente desconectado e depois conectado ao sistema. / Mestre em Ciências
|
210 |
Modelo multiobjetivo de alocação e dimensionamento de geração distribuída para redes de distribuiçãoZanin Júnior, Paulo Sérgio 20 April 2018 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2018-05-07T12:48:18Z
No. of bitstreams: 2
Dissertação - Paulo Sérgio Zanin Júnior - 2018.pdf: 9799514 bytes, checksum: 91a3707c80f8aa8c8ee94301653047f9 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2018-05-07T13:03:18Z (GMT) No. of bitstreams: 2
Dissertação - Paulo Sérgio Zanin Júnior - 2018.pdf: 9799514 bytes, checksum: 91a3707c80f8aa8c8ee94301653047f9 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-05-07T13:03:18Z (GMT). No. of bitstreams: 2
Dissertação - Paulo Sérgio Zanin Júnior - 2018.pdf: 9799514 bytes, checksum: 91a3707c80f8aa8c8ee94301653047f9 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Previous issue date: 2018-04-20 / Distributed generation represents a new paradigm to the electricity offer expansion in distribution networks, which has been studied in several aspects. This dissertation aims to propose a multi-objective sizing and siting analysis model to assist the distributed generation units planning, based on three perspectives of concern: technical aspect, from the distribution company viewpoint, financial aspect, from the distributed generation owner’s viewpoint, and social-environmental aspect, from the society viewpoint. In this analysis, a genetic algorithm and the Maximin metric are implemented to obtain a Pareto optimal solutions set. As to decision-making analysis, the present value distributed generators net income; minimum losses set; and the Max-Min approximation are used to choose a final solution from the Pareto set. Study cases are accomplished using distribution networks by the proposed model and Pareto-sets are obtained, which allow the view of the best solutions. The mentioned decision-making analysis is applied to capture one of the Pareto-set solutions. Therefore, the results enable the choice of a distributed generation siting and sizing set and also allow complementary analysis referring to generation sources and the model itself. / A geração distribuída representa um novo paradigma para expansão da oferta de eletricidade em redes de distribuição e tem sido estudada em diversos aspectos. Este trabalho propõe um modelo multiobjetivo de alocação e dimensionamento para auxiliar o planejamento de unidades de geração distribuída, baseado em três perspectivas de interesse: aspecto técnico, do ponto de vista da companhia de distribuição; aspecto financeiro, do ponto do empreendedor de geração distribuída; e aspecto socioambiental, do ponto de vista da sociedade como um todo. Nesta análise, um algoritmo genético e a métrica Maximin são implementados para obter um conjunto de soluções ótimas de Pareto. Para a análise de tomada de decisão, de forma a escolher uma solução final do conjunto de Pareto, são utilizados: o valor presente da receita líquida total dos geradores distribuídos; configuração de perdas mínimas; e a aproximação Max-Min. São realizados estudos de caso em redes elétricas de distribuição por meio do modelo proposto e são obtidos conjuntos de Pareto, que permitem visualização das melhores soluções e então a análise de tomada de decisão é aplicada para apreender uma das soluções do conjunto-Pareto. Dessa forma, os resultados permitem a escolha de uma das possíveis configurações de alocação e dimensionamento de geração distribuída e também permitem análises complementares referentes às fontes de geração e ao próprio modelo proposto.
|
Page generated in 0.1119 seconds