• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 26
  • Tagged with
  • 26
  • 26
  • 9
  • 8
  • 8
  • 7
  • 6
  • 6
  • 5
  • 5
  • 5
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação de um aparelho de luz halógena e um dispositivo Leds na técnica de fotoativação trans-dental : estudo da profundidade de polimerização pelos testes de dureza e espectroscopia de fluorescência /

Rastelli, Alessandra Nara de Souza. January 2004 (has links)
Orientador: Marcelo Ferrarezi de Andrade / Banca: Fernando Carlos Hueb de Menezes / Banca: João Carlos Gomes / Banca: José Roberto Cury Saad / Banca: Vanderlei Salvador Bagnato / Resumo: O objetivo desse trabalho foi avaliar a capacidade de polimerização de uma fonte de luz halógena e um dispositivo LEDs utilizados na técnica de fotoativação trans-dental. Para isto, foram confeccionadas amostras em uma matriz metálica circular contendo um orifício central com 4 mm de diâmetro e 2 mm de profundidade (ISO 4049) utilizando-se a resina composta microhíbrida Filtek Z-250 (3M/ESPE), na cor A2. Cinco amostras foram confeccionadas para cada situação diferente, distribuídas em grupos da seguinte maneira: GRUPO I - aparelho Curing Light e dispositivo LEDs utilizados pelos tempos de exposição de 40 e 60 segundos, para as espessuras de 0 (grupo controle); 1,0 mm; 2,0 mm e 3,0 mm de faceta de estrutura dental, nas mesmas condições de operação armazenados em meio seco por 24 horas, avaliados pelo teste de dureza Vickers (VHN); GRUPO II - aparelho Curing Light e dispositivo LEDs utilizados pelos tempos de exposição de 40 e 60 segundos, para as espessuras de 0 (grupo controle); 1,0 mm; 2,0 mm e 3,0 mm de faceta de estrutura dental nas condições originais de operação armazenados em meio seco por 24 horas e 30 dias, água destilada, saliva artificial e ácido acético a 10% por 30 dias, avaliados pelo teste de dureza Vickers (VHN) e GRUPO III - aparelho Curing Light e dispositivo LEDs utilizados pelos tempos de exposição de 40 e 60 segundos, para as espessuras de 0 (grupo controle); 1,0 mm; 2,0 mm e 3,0 mm de faceta de estrutura dental armazenados em rodamina 6G durante 24 horas sendo avaliados pelo teste de espectroscopia de fluorescência. Os dados foram submetidos à Análise Estatística de Variância (p<0,05) e complementadas por comparações múltiplas pelo teste de Newman-Keuls ao nível de 5% de significância. Baseados nos resultados encontrados, pudemos concluir que: 1) a fonte de luz halógena testada proporcionou... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The objective of this study was evaluate the light-curing capacity, throught dental structure, of two differents light-curing device (Halogen and LEDs), by hardness and fluorescent spectroscopic testings. The samples were made in a circular metallic mold with a orifice in the central portion measuring 4 mm in diameter and 2 mm in thickness (ISO 4049). The composite resin was used the Filtek Z-250 (3M/ESPE) at collor A2. Five samples were made by situation analyzed: GROUP I - halogen and LEDs light-curing devices by exposure times of 40 and 60 seconds for the thickness 0 (control group); 1,0 mm; 2,0 mm and 3,0 mm of the structure dental facet, at the same operation parameters stored in dry mean for 24 hours; GROUP II - halogen and LEDs light-curing devices by exposure times of 40 and 60 seconds for the thickness 0 (control group); 1,0 mm; 2,0 mm and 3,0 mm of the structure dental facet, at the original operation parameters stored in dry mean for 24 hours and thirty days, distilled water, artificial saliva and acetic acid at 10% for thirty days and GROUP III - halogen and LEDs light-curing devices by exposure times of 40 and 60 seconds for the thickness 0 (control group); 1,0 mm; 2,0 mm and 3,0 mm of the structure dental facet stored in 6G rodhamine evaluated for fluorescent spectroscopic testing. The data were submitted to the Statistical Analysis of Variance (p <0,05) and complemented by multiple comparisons by the test of Newman-Keuls at the level 5% of significance. Based on the found results, we could end that: 1) the device of tested halogen light provided larger curing of depth for the trans-dental technique; 2) the device LEDs promoted larger curing of depth for the trans-dental technique, when the source of halogen light was used in the same operation parameters; 3) in the technique trans-dental, independent of the source of used... (Complete abstract, click electronic address below). / Doutor
2

Efeito da fumaça de cigarro nas propriedades de resinas compostas e substratos dentais /

Takeuchi, Cristina Yoshie Garcia. January 2007 (has links)
Resumo: O objetivo do presente estudo foi avaliar in vitro a microdureza, mudança de cor e presença de substâncias tóxicas após exposição à fumaça de cigarro na resina composta, dentina e esmalte dental e avaliar in situ a microdureza, rugosidade superficial e alteração de cor (?E) e luminosidade (?L) de resinas compostas frente à exposição à fumaça do cigarro associado à escovação. Para a fase in vitro foram confeccionados corpos-de-prova de resina composta (RC), esmalte (E) e dentina radicular bovina (DR) que foram planificados, polidos e expostos a fumaça de 10 cigarros/dia por 8 dias. Avaliou-se a microdureza Knoop e a alteração da cor (CIELAB) antes e depois do ato de fumar. Em seguida, as amostras foram preparadas para análise em microscopia eletrônica de varredura (MEV) e microanálise (EDS). Os dados da microdureza e da alteração de cor foram submetidos à ANOVA e Tukey (5%). A microdureza do E aumentou e da DR e RC diminuíram. Na alteração de cor a RC e o E apresentaram menor escurecimento do que a DR. Na fase in situ foram confeccionados corpos-de-prova com três tipos de resinas compostas que foram fixados em aparelho intrabucal palatino. Foram selecionados 22 voluntários, sendo 11 fumantes e 11 não-fumantes, que utilizaram o aparelho por 28 dias. A escovação dos espécimes foi realizada fora da boca, três vezes por dia somente na metade do dispositivo. Para os fumantes foi estipulado o consumo de 10 cigarros/dia. A mensuração da cor (CIELAB), da microdureza (KHN) e da rugosidade foram realizadas antes e após os 28 dias de exposição in situ. Os dados KHN foram analisados pela ANOVA e teste de Fisher's LSD. Os dados da rugosidade, ?E e o ?L foram analisados pelo método estatístico não-paramétrico Kruskal-Wallis, Wilcoxon e Friedman (p<0.05) que observaram que a fumaça de cigarro aumentou os valores... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to assess in vitro the microhardness, color change and the presence of toxicant elements deriving from cigarette smoke in the composite resin, dentine and dental enamel and to evaluate in situ the microhardness, surface roughness and color change (?E) and lightness (?L) of composite resins upon cigarette smoke exposure associated with brushing. For the in vitro phase were fabricated specimens from composite resin (CR), enamel (E) and root dentin (RD) fragments that were wet ground and polished and exposed to the smoke of 10 cigarettes/day during 8 days. Knoop microhardness number (KHN) and the color was measured before and after exposure. After the samples were prepared for analysis with Scanning Electron Microscopy (SEM) and microanalysis (EDS). Data were submitted to ANOVA and Tukey's test (p<0.05). The microhardness of the E increased and the RD and CR decreased. The CR and E presented statistically significant less darkening and color change than RD. For the in situ phase were fabricated specimens three different composite resins that were attached to removable palatal appliance. Twenty-two volunteers took part in this study (11 smokers e 11 non-smokers) and received instructions to wear the appliances continuously by 28 days. For brushing of the specimens, the appliance was taken out the mouth and three times a daily was brushed. For the smokers, it was standardized consume of 10 cigarettes for day. The color changes (?E), microhardness (KHN) and surface roughness were measure before and after 28 days the exposure in situ. The microhardness data were analyzed by ANOVA and Fisher's LSD test. The roughness data, ?E and the ?L were analyzed by Kruskal-Wallis, Wilcoxon and Friedman (p<0.05). The cigarette smoke increased the microhardness and roughness values for smokers with brushing. Concluding that laboratory phase the cigarette smoke affected the... (Complete abstract click electronic access below) / Orientador: Welingtom Dinelli / Coorientador: Regina Guenka Palma-Dibb / Banca: José Roberto Lovadino / Banca: Linda Wang / Banca: Patrícia Petromilli Nordi Sasso Garcia / Banca: Marcelo Ferrarezi de Andrade / Doutor
3

Microdureza superficial do cimento resinoso de ativado por duas diferentes fontes de luz com interposição de cerômero e porcelana /

Alencar Júnior, Emmanuel Arraes de. January 2005 (has links)
Orientador: Sizenando de Toledo Porto Neto / Resumo: Nessa pesquisa utilizou-se de três unidades fotoativardoras na polimerização de uma marca comercial de cimento resinoso de dupla ativação, com a interposição de uma lâmina de cerômero e de porcelana, para avaliar a microdureza superficial do cimento resinoso, considerando sua superfície do topo e da base Os corpos-de-prova foram confeccionados utilizando-se matrizes metálicas com 2mm de espessura e 16mm de diâmetro, com o orifício central medindo 8mm de diâmetro (figura 4), coincidindo com o diâmetro da ponta dos aparelhos de luz. Como espaçadores foram utilizados anéis metálicos com 2mm e 4mm de altura confeccionados de cerâmica e cerômero, na tentativa de se reproduzir as espessuras médias das restaurações indiretas realizadas clinicamente. Foram realizados quatro corpos-de-prova para cada grupo, com os três aparelhos fotoativadores e para cada grupo do material intermediário. A inserção da resina no orifício central da matriz foi realizada em uma única porção, utilizando-se de uma seringa Centrix. Após a inserção do cimento, obteve-se um pequeno excesso do material. Sobre o cimento a foi colocada uma tira de poliéster e posicionado peso de um quilo para a homogeneização e planificação da superfície. Após a remoção do peso, foi executada a ativação do cimento resinoso com a ponta dos aparelhos de luz utilizados no experimento, posicionado diretamente sobre as pastilhas de cerâmica e cerômero. Os corpos-de-prova foram removidos da matriz metálica, acondicionados em recipientes à prova de luz e mantidos a temperatura de 37o C durante 24 horas. As superfícies do topo e da base do corpo-de-prova foram polidas com lixas d'água em graus descendentes (800, 320 e 600 norton) de abrasividade e submetidas ao teste de microdureza. Para a determinação da microdureza, foi utilizado o aparelho Microdurômetro Digital MHT-110 MICROHARDNESS TESTER, Anton... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The aim of this study was to evaluated the efficiency of three different units of light curing in activating a commercial trend of resin cement. The body-of-test had been confectioned using first metallic with 2mm of thickness and 16mm of diameter, with the central orifice measuring 8mm of diameter (figure 4), coinciding with the diameter of the tip of the light devices. As spacers metallic rings with 2mm and 4mm of height confectioned of ceramics had been used and cerômero, in the attempt of if clinically reproducing the average thicknesses of the carried through indirect restorations. They had been carried through four body-of-test for each group, with the three devices photo curing and for each group of the intermediate material. The insertion of the resin in the central orifice of the matrix was carried through in an only portion, using itself of a Centrix syringe. After the insertion of the cement, got a small excess of the material. On the cement a polyester strap was placed it and located weight of one kilo for the homogenization and planning of the surface. After the removal of the weight, was executed the activation of the resin cement with the tip of the devices of light used in the experiment, located directly on the tablets of ceramics and ceromer. The test bodies had been gotten thus the body-of-test had been removed of the metallic matrix, conditioned in containers to the test of light and kept the temperature of 37o C during 24 hours. The surfaces of the top and the base of the body-of-test had been polishing with sandpapers in degrees descending (800, 320 and 600 norton) of abrasiveness and submitted to the micro hardness test. For the determination of the micro hardness, the device Digital Micro hardness tester MHT-110 MICROHARDNESS TESTER, Anton Paar-Paar Physica, Graz was used, Austria, of the Institute of Chemistry of Araraquara (UNESP) with load of 50N during 30 seconds... (Complete abstract, click electronic address below) / Doutor
4

Desenvolvimento de equipamento para avaliação em campo da dureza de madeiras para dormente ferroviário /

Colenci, Roberto Antonio, 1956- January 2006 (has links)
Orientador: Adriano Wagner Ballarin / Banca: Luiz Antonio Targa / Banca: Ivaldo de Domenico Vareli / Banca: João Alberto Borges de Araujo / Banca: Nilson Franco / Resumo: A propriedade mecânica denominada dureza é largamente utilizada na especificação de materiais, nos estudos e pesquisas mecânicas e metalúrgicas e no controle de qualidade de diversos materiais. No caso particular da madeira, dentre as diversas propriedades mecânicas empregadas como ferramentas para avaliação da sua qualidade e de seu potencial tecnológico, tem destaque a dureza Janka, que avalia a relação entre uma força de penetração superficial de uma pequena esfera de aço na madeira e a endentação promovida por essa esfera. Constitui-se em ensaios simples, rápido, e com boas correlações com a resistência à compressão paralela às fibras da madeira, referência maior na classificação estrutural deste material. Mais recentemente, trabalhos internacionais reportaram o uso da dureza Brinell para avaliação de madeiras. Além das vantagens já reportadas para a dureza Janka, a dureza Brinell traria a facilidade de realização dos ensaios em condições de campo, sobretudo pela menor magnitude dos esforços envolvidos na cravação do endentador na superfície do material. Dando continuidade a estudos já desenvolvidos, este trabalho teve como objetivo estudar critérios ou práticas, aplicáveis no campo e em exemplares individuais, para a qualificação mecânica de algumas espécies de madeira com a finalidade de classificação, e aprovação ou reprovação de lotes de dormentes de madeira para uso ferroviário. Os estudos iniciais conduziram ao projeto e desenvolvimento de equipamento 2 para avaliação em campo da dureza de madeiras - Durômetro portátil para madeiras embasado, no geral, na metodologia Brinell com mensuração dos diâmetros da calota endentada no material sob análise. Os ensaios de teste funcional e de calibração do equipamento foram conduzidos utilizando-se 16 lotes de madeiras de reflorestamentos e nativas... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The mechanical property called hardness is largely used in material specifications, in mechanical and metallurgical studies and research and in the quality control of several kinds of materials. Specifically for timber, among the several mechanical properties used as tools for its quality control and technological potential, Janka hardness, which evaluate the relation between a superficial penetration force of a small steel sphere in wood and the indentation produced by such sphere, are highlighted. It is constituted by simple, quick and easily performed test, with good correlations with the compression parallel to grain strength, a high reference in structural classification for this material. More recently, international studies have reported the use of Brinell hardness for timber assessment. Besides the advantages previously mentioned for Janka hardness, the Brinell one would make it easier to perform the tests in field conditions, especially for its lower magnitude in terms of the involved loads. Continuing studies already developed with such property for timber, this work had the objective of studying criteria or practices applicable on field and in individual wood elements, for the mechanical qualification of some timber species towards its classification, and approval or failing of timber sleeper lots for rail usage. The initial studies led to the project and development of an equipment for timber hardness field evaluation - portable Hardometer for timber. 4 The functional and calibration test of the equipment were carried out using 16 native and exotic timber lots, among there E.citriodora, E. tereticornis, E. saligna, E. urophylla, E. grandis, Goupia glabra (Cupiúba) and Bagassa guianenses (Tatajuba), with variation of origins beyond species. Each lot had 12 specimens. The calibration tests, performed with timber on its moisture above the FSP (fiber saturation point)... (Complete abstract click electronic access below) / Doutor
5

Influência do método de processamento, sinterização convencional ou injeção a vácuo, na resistência à flexão e dureza de porcelanas feldspáticas /

Oliva, Eduardo Andrade de. January 2006 (has links)
Orientador: Carlos Alberto dos Santos Cuz / Banca: Sicknan Soares da Rocha / Banca: André Ulisses Dantas Batista / Banca: Renata Garcia Fonseca / Banca: Andréia Affonso Barreto Montandon / Resumo: O objetivo deste trabalho foi avaliar, por meio de ensaios de resistência à flexão, em três pontos, e de dureza, o comportamento mecânico das porcelanas feldspáticas Duceram Plus, Excelsior, Duceragold, Symbio, VMK, Omega 900 e Vitadur Alpha, submetidas a dois métodos de processamento laboratorial: sinterização convencional (fabricantes) e por injeção a vácuo (experimental). Foram confeccionadas dez amostras de cada grupo experimental para o ensaio de resistência à flexão (em forma de barra, 25mm de comprimento, 5mm de largura, 2mm de espessura - ISO 6872). Os testes foram realizados em equipamento MTS 810 (Material Test System, EUA), com célula de carga de 10kN e velocidade de 0,5mm/minuto, gerenciado por programa Test Star II (IBM, EUA). Para o ensaio de dureza, na escala Vickers, cinco fragmentos de cada grupo foram incluídos em resina acrílica autopolimerizável, polidos e submetidos ao teste em durômetro Buheler (EUA), com carga de 300gf, por 30 segundos. As cerâmicas Duceram Plus, Excelsior, Omega 900, Symbio e VMK 95 apresentaram maior resistência à flexão quando processadas por injeção. Os materiais Ducera Gold e Vitadur Alpha não sofreram qualquer influência deste método de processamento. O processo de injeção a vácuo, experimental, não alterou a dureza dos materiais estudados. / Abstract: The aim of this study was to compare the flexural strength and hardness of seven feldspatic ceramics (Duceram Plus, Excelsior, Duceragold, Symbio, VMK, Omega 900 and Vitadur Alpha) processed by convencional fusing and heat-pressing. Ten especimens were made for flexural test (25mm length; 5mm width; 2mm thick - ISO 6872). The tests were realized in a MTS 810 machine (Material Test System - USA), with a 10kN load cell and crosshead-speed of 0.5mm/minute, managed by Test Star II software (IBM, USA). Five samples of each ceramic were included in autocured resin JET (Artigos odontológicos Clássico, Brazil), polished and submitted to Vickers hardness test in duromer Buheler (USA), with load of 300gf, for 30 seconds. Results showed that the ceramics Duceram Plus, Excelsior, Omega 900, Symbio and VMK 95 presented higher flexural stengths values when heat-pressed. Ducera Gold and Vitadur Alpha flexural stengths values werenþt affected by the processing method. / Doutor
6

Estudo da dureza e do grau de conversão de resinas compostas : efeito de fonte de luz e material /

Ribeiro, Benícia Carolina Iaskieviscz. January 2010 (has links)
Orientador: José Roberto Cury Saad / Banca: Margareth Oda / Banca: Anísio Lima da Silva / Banca: Celso Luiz de Angelis Porto / Banca: José Cláudio Martins Segalla / Resumo: A evolução dos materiais odontológicos, a interação de resinas compostas e aparelhos fotopolimerizadores motivaram a realização deste estudo. Foram selecionadas quatro resinas compostas fotopolimerizáveis indicadas para restaurações diretas, sendo três microhíbridas: Vit-l-escenceTM (Ultradent®), Amelogen® Plus (Ultradent®) e Opallis (FGM) e outra de nanopartículas: FiltekTM Z350 (3M ESPE Dental Products), todas indicadas para dentina e na cor A2. Construiram-se corpos-de-prova com dimensões de 4 mm de diâmetro e 2 mm de profundidade (ISO 4049), os quais foram polimerizados por diferentes aparelhos fotoativadores. Para o primeiro estudo, utilizou-se o Led Ultra Lume Led 2 (Ultradent®) e uma luz halógena (Ultralux - Dabi Atlante), esta com diferentes ponteiras condutoras de luz. Decorridas 24 horas, os corpos-de-prova foram submetidos ao ensaio de dureza utilizando-se um aparelho MMTT-3 Microhardness Tester (Buehler Lake Bluff, Illinois USA), com o qual foram realizadas quatro aferições na superfície do topo da amostra (dureza 1) e mais quatro na superfície de base (dureza 2) oposta à fonte de luz. Para o segundo estudo, novos corpos-de-prova foram confeccionados da mesma maneira, utilizando-se a luz halógena (Ultralux Dabi Atlante) com ponteira de vidro, um LED de terceira geração (Ultra Lume Led 5 Ultradent®) e dois leds de segunda geração: Radii-Cal (SDI) e Elipar Free LightTM 2 da 3M ESPETM. Os corpos-deprova foram submetidos ao mesmo teste, em dois tempos: imediato e após 24 horas. Para a terceira pesquisa, pela qual se avaliou o grau de conversão por FT-IR, empregando-se o espectrofotômetro Nexus FT- IR, confeccionou-se do mesmo modo outros corpos-de-prova e, decorridas 24 horas, estes foram triturados e misturados com KBr para a obtenção de pastilhas. Como parâmetro, confeccionou-se mais 20 pastilhas com resinas não curadas... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Our study was motivated by the evolution of dental materials, and the interaction between composite resin and light curing units. We selected four light-curing composite resins suitable for direct restorations, in shade A2, three microhybrid (Vit-l-escenceTM - Ultradent®) (Amelogen® Plus - Ultradent ®) (Opallis - FGM) and one nanoparticles (FiltekTM Z350 - 3M ESPE Dental Products), all indicated for dentin. All specimens were built with dimensions of 4mm diameter and 2mm deep, (ISO 4049) which were irradiated by different light-curing units. For the first study, we used the Led Ultra Lume Led 2 (Ultradent®), and a halogen light (Ultralux - Dabi Atlante) with the last having different conductive tips of light. At 24 hours, samples were tested in microhardness through the device MMTT-3 Microhardness Tester (Buehler Lake Bluff, Illinois USA) where 4 measurements were performed in the top surface (hardness 1) and 4 more in the base area (hardness 2), opposite to the source of light. For the second study, new specimens were prepared in the same way, using the Light Halogen (Ultralux Dabi Atlante) with a glass pipette, a third-generation led (Ultra Lume Led 5 Ultradent®) and two second-generation LEDs: Radii-Cal (SDI) and Elipar Free LigthTM 2 (3M ESPETM). The samples were subjected to the same test in two stages: immediate and after 24 hours. For the third study, which evaluated the degree of conversion by FT-IR, using the spectrophotometer Nexus FT-IR, samples were built in the same manner and after 24 hours they were powdered and mixed with KBr, to obtain tablets. As a parameter, 20 more tablets were prepared with uncured resin. Data were collected and subjected to statistical analysis. In the first study, it was concluded that the led device (second generation) allowed polymerization and the resulting hardness values were equivalent to the halogen unit for three of the four... (Complete abstract click electronic access below) / Doutor
7

Caracterização mecânica, física e química das ligas Ti-35Nb-5Zr e Ti-35Nb-10Zr /

Ribeiro, Ana Lúcia Roselino. January 2008 (has links)
Orientador: Luis Geraldo Vaz / Banca: Carlos Alberto dos Santos Cruz / Banca: Rubens Caram Junior / Resumo: Nas áreas médica e odontológica, a utilização do titânio para a substituição de estruturas biológicas se confirmou a partir do reconhecimento de suas excelentes propriedades. Com o objetivo de atingir melhores propriedades mecânicas, não alterando, porém, sua biocompatibilidade, foi proposto adicionar nióbio e zircônio ao titânio, formulando-se duas ligas metálicas Ti-35%Nb-5%Zr (liga 1) e Ti-35%Nb- 10%Zr (liga 2) (%m/m). As ligas foram caracterizadas por propriedades mecânicas, físicas e químicas. Para a obtenção das ligas foi utilizado um forno de fusão a arco-voltáico com atmosfera inerte, controlada por bomba de vácuo e fluxo de argônio. A análise química das amostras foi realizada por fluorescência de raios X, e a avaliação microestrutural, por microscopia eletrônica de varredura e difratometria de raios X. Os testes mecânicos realizados foram: dureza Vickers, resistência à tração, ciclagem mecânica por tração e análise de fratura. Os resultados permitiram caracterizar a liga 1 como do tipo α+β e a liga 2 como do tipo β. Conclui-se que a liga 1 apresentou maior dureza e menor resistência à tração do que a liga 2. As fraturas, após o teste de tração, foram do tipo dúctil e, após a ciclagem mecânica, foram do tipo mista para ambas as ligas. As características estudadas mostram que as ligas 1 e 2 são promissoras para a fabricação de implantes dentários. / Abstract: In medical and dentistry areas, the use of titanium for the substitution of biological structures has been confirmed since recognition of its excellent properties. With the objective of exploiting better mechanical properties, not altering, however, its biocompatibility, it was intended to add niobium and zirconium to the titanium, being formulated two metallic alloys Ti- 35%Nb-5%Zr (alloy 1) and Ti-35%Nb-10%Zr (alloy 2) (%m/m). The alloys were characterized through mechanical, physics and chemistries properties. For obtaining the alloys an arc-melting furnace was used under inert atmosphere, controlled by vacuum bomb and argon flow. The chemical analysis of the samples was accomplished by X -ray fluorescence, and the microestrutural evaluation by scanning electron microscopy and X-ray diffraction. The performed skilled mechanical tests were: Vickers hardness, tensile strength, mechanical cycling, and fracture analysis. The results allowed characterizing the alloy 1 as α+β type and the alloy 2 as β type. It is found that the alloy 1 presented larger hardness and smaller tensile strength than the alloy 2. The fractures, after the tensile test, were of the ductile type and, after the mechanical cycling, they were of the mixed type for both alloys. The studied characteristics have shown that the alloys 1 and 2 may be promises compounds for manufacture of dental implant. / Mestre
8

Desgaste abrasivo e dureza de seis resinas compostas expostas a diferentes tempos de fotopolimerização com aparelhos de LED e lâmpada incandescente /

Ulhôa, Michele Paoline de Marins. January 2006 (has links)
Orientador: Eduardo Carlos Bianchi / Banca: Cesar Antunes de Freitas / Banca: Paulo Noronha Lisboa Filho / O Programa de Pós-Graduação em Ciência e Tecnologia de Materiais, PosMat, tem caráter institucional e integra as atividades de pesquisa em materiais de diversos campi da Unesp / Resumo: A Humanidade, ao buscar as melhoras nas suas condições de vida, vem desenvolvendo materiais capazes de reparar e melhorar imperfeições naturais e acidentais. Encontra nas resinas compostas, constantemente utilizadas por dentistas, uma maneira de reparar imperfeições e perdas de materiais dentários no ser humano. A escolha de resinas compostas em substituição aos antigos materiais de restauração, como o amálgama, se dá pelo fato de serem fáceis de preparar, apresentarem menor desgaste, serem praticamente imperceptíveis após sua aplicação devido à grande quantidade de cores fornecidas pelos fabricantes. Porém não apresentam desgaste semelhante ao do esmalte dentário, sendo necessária substituição com o passar do tempo, devido ao desgaste abrasivo. Dentre os vários fatores determinantes do processo de desgaste abrasivo, encontram-se, genericamente, as características da própria resina e do preparo cavitário, assim como da restauração confeccionada e das condições das agressões a que ela for submetida. Para fazer a medição da resistência ao desgaste abrasivo, utilizou-se o método do disco retificado aperfeiçoado para Odontologia (COELHO, 1991; BIANCHI et al., 2002). É utilizado um banco de ensaios onde um disco dinâmico revestido com porcelana desgasta um disco estático revetido com a resina polimerizada em um tempo pré-estabelecido... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Humanity, when searching for a better life conditions, is developing materials capable to repair and to improve natural and accidental imperfections. It finds in composite resins, constantly used for dentists, a way to repair imperfections and losses of human dental material. The composed resin choice in substituion to the old restoration materials, as the amalgamates, it is for the fact of being easy to prepare, to present less wear, to be practically invisible after its application due to great amount of colors supplied for the manufacturers. However they do not show similar wear as the dental enamel, being necessary the substitution after a while, due to the abrasive wear. Among some determinative factors of the process of abrasive wear, there are, generically, the characteristics of the resin and the cavitary preparation, as well as the confectioned restoration and the conditions of the aggressions that it is submitted. To make the measurement of the resistance to the abrasive wear, the method of the rectified circular surface improved for odontology was used (COELHO, 1991; BIANCHI et al., 2002). A Test bench is used where a dynamic circular surface covered with porcelain consumes a static circular surface covered with the polymerized resin in a pre-established time... (Complete abstract, click electronic address below) / Mestre
9

Efeito de tratamentos térmicos na resistência à tração e na dureza Vickers do Ti c.p. e da liga Ti-6Al-4V obtidos por fundição odontológica /

Rocha, Sicknan Soares da. January 2002 (has links)
Orientador: Gelson Luis Adabo / Banca: Luís Geraldo Vaz / Banca: Guilherme Elias Pessanha Henriques / Resumo: O objetivo desta investigação foi determinar se os tratamentos térmicos podem alterar a resistência à tração e a dureza Vickers do Ti c.p. e da liga Ti-6Al-4V. Trinta corpos-de-prova na forma de halteres com 3,0 mm no segmento central e 42 mm de comprimento, obtidos por meio de uma matriz de alumínio, foram fundidos no sistema Rematitan. Os corpos-de-prova de Ti c.p. e Ti-6Al-4V foram divididos aleatoriamente em três grupos de 10 cada, e submetidos às seguintes condições de tratamento térmico: (1) controle; (2) T1 - aquecimento a 750ºC/2 h; (3) T2 - recozimento a 955ºC/1 h e envelhecimento a 620ºC/2 h. Ambos, aquecimento e resfriamento, foram realizados em atmosfera controlada de argônio. O ensaio de tração foi efetivado na máquina de testes mecânicos MTS modelo 810 à velocidade de 1,0 mm/min. Após o teste de tração uma das extremidades do corpo-de-prova foi embutida em resina acrílica, regularizada e polida antes da medida da dureza Vickers no durômetro Micromet 2100. As médias de resistência à tração e dureza Vickers foram comparadas estatisticamente usando o teste não-paramétrico de Kluskall-Wallis. Nos grupos de Ti c.p. não foram observadas diferenças significativas na resistência à tração, entretanto, na dureza Vickers os resultados do grupo T2 foram significativamente maiores que os outros grupos, que se mostraram iguais entre si. Na liga Ti-6Al-4V os grupos controle e T1 revelaram igualdade estatística em relação à resistência à tração, e significativamente superiores ao grupo T2. Quanto à dureza Vickers, diferenças estatisticamente significantes foram observadas entre os três grupos de tratamento térmico: T2>T1>controle. Não foi observada correlação entre as propriedades de resistência à tração e dureza Vickers. ...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this investigation was to determine whether heat treatments could change the tensile strength and Vickers hardness of CP Ti and Ti-6Al-4V alloy castings. Thirty dumbbell rods, 3.0 mm in diameter at the central segment and 42 mm in length, obtained from an aluminum matrix, were cast for each metal in the Rematitan system. The specimens of CP Ti and of alloy Ti-6Al-4V, were divided randomly into three groups of ten each; then submitted to the following heat treatments: (1) control group, without heat treatment; (2) T2 - heat at 750ºC for 2 h; (3) annealing at 955ºC for 1 h and aged at 620ºC for 2 h. The heat treatments, as well as the cooling process were conducted in the furnace with argon atmosphere. The tensile strength was measured by means of a universal testing machine, MTS model 810, at a strain of 1.0 mm/min. After the tensile testing the specimens were embedded in acrylic resin, grounded and polished prior to hardness measurements, using the Vickers tester Micromet 2100. The means and standard deviations of tensile strength and Vickers hardness were statistically compared using Kruskal-Wallis non-parametric test at a=0.05 significance level. In CP Ti groups, no statistically significant differences in tensile strength were observed; however, in Vickers hardness the results of group T2 were significantly higher than the other groups, which showed similar mean values among themselves. In Ti-6Al-4V alloy, the control and T1 groups revealed statistically higher tensile strength when compared to T2 group, with no significant difference between control and T1 group. Regarding Vickers hardness, statistically significant differences were observed among the three heat-treatment groups: T2>T1>control...(Complete abstract, click electronic access below) / Mestre
10

"Avaliação da profundidade de polimerização de uma resina composta, pela técnica trans-dental, utilizando-se três diferentes fontes de luz : halógena, laser de argônio e leds" /

Rastelli, Alessandra Nara de Souza. January 2002 (has links)
Resumo: O objetivo desse trabalho foi avaliar a capacidade de polimerização, através da estrutura dental, de três diferentes fontes de luz (Halógena, Laser de Argônio e LEDs), por meio do teste de microdureza. Para isto, foram confeccionados corpos-de-prova em uma matriz metálica circular contendo um orifício na porção central com 4 mm de diâmetro e 2 mm de profundidade. Utilizou-se a resina composta microhibrida Charisma (Heraeus-Kulzer), na cor A2, para a confecção dos corpos-de-prova. Cinco corpos-de-prova foram confeccionados para cada situação diferente, perfazendo um total de 140 corpos-de-prova, distribuídos em 3 grupos da seguinte maneira: GRUPO I - fonte de luz halógena utilizada pelos tempos de exposição de 20 e 40 segundos, para as espessuras de 0 (grupo controle); 1,2 mm; 1,5 mm e 2,0 mm de faceta de estrutura dental; GRUPO II - fonte de luz de laser de argônio utilizada pelos tempos de exposição de 20 e 40 segundos, para as espessuras de 0 (grupo controle); 1,2 mm; 1,5 mm e 2,0 mm de faceta de estrutura dental e GRUPO III - fonte de luz à base de LEDs utilizada pelos tempos de 20, 40 e 60 segundos, para as espessuras de 0 (grupo controle); 1,2 mm; 1,5 mm e 2,0 mm de faceta de estrutura dental. Após a confecção dos corpos-de-prova, estes foram armazenados em estufa a 37ºC durante 24 horas. Após o período de armazenamento, procedeu-se o teste de microdureza Vickers, realizando-se 12 impressões para a superfície de topo (voltada à fonte de luz) e 12 para a superfície de base (oposta à fonte de luz). Os dados foram submetidos à Análise Estatística de Variância (P<0,05). Os valores dos desvios padrão das medidas de microdureza foram menores do que 1% da média, indicando diferença estatisticamente significante entre quase todos os grupos. Baseados nos resultados encontrados, pudemos concluir que... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The objective of this study was evaluate the light-curing capacity, throught dental structure, of three differents light-curing device (Halogen, Argon Laser and LEDs), by microhardness testing. The specimes were made in a circular metallic mold with a of orifice in the cental portion measuring 4 mm in diameter and 2 mm in thickness. The composite resin was used the Charisma (Heraeus-Kulzer) at collor A2. Five samples was made by situation analyzed, adding up one hundred and forty samples: GROUP I - halogen light-curing device by exposure times of 20 and 40 seconds for the thickness 0 (control group); 1,2 mm; 1,5 mm and 2,0 mm of the structure dental facet; GROUP II - argon laser light-curing device by exposure times of 20 and 40 seconds for the thickness 0 (control group); 1,2 mm; 1,5 mm and 2,0 mm of the structure dental facet and GROUP III - LEDs light-curing device by exposure times of 20, 40 and 60 seconds for the thickness 0 (control group); 1,2 mm; 1,5 mm and 2,0 mm of the dental structure facet. After the polymerization procedures the specimes were stored at room temperature of 37ºC for 24 hours. After the storing, the microhardness testing was made, take effecting 12 impressions for the top surface and 12 for the botton surface. The hardness values means obtained were calculed and the statistically analised using Anova (P<0,05). According to the results, it was conclude that: 1) highest the thickness of the dental estructure face, have been a decreasing of the means values of microhardness, independent of the light-cured device utilized; 2) highest exposure times provided higher values means of the microhardness, independent of the light-cured device utilized; 3) the top surface showed the highest means values of hardness, independent of the light-cured device utilized; 4) the halogen light-cured device raised suitable... (Complete abstract, click electronic address below). / Orientador: Marcelo Ferrarezi de Andrade / Coorientador: Vanderlei Salvador Bagnato / Banca: Sillas Luiz Lordelo Duarte Júnior / Banca: João Carlos Gomes / Mestre

Page generated in 0.1039 seconds