• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 217
  • 75
  • 24
  • 21
  • 12
  • 12
  • 10
  • 9
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • Tagged with
  • 480
  • 154
  • 110
  • 104
  • 89
  • 65
  • 56
  • 55
  • 53
  • 49
  • 43
  • 38
  • 37
  • 35
  • 34
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Desenvolvimento da técnica de tomografia por coerência óptica de autocorrelação e melhoramento de resolução axial por análise de sinal via transformada de Fourier / Development of autocorrelation optical coherence tomography technique and axial resolution enhancement through Fourier Transform analysis

Marcus Paulo Raele 18 November 2013 (has links)
Tomografia por Coerência Óptica, ou simplesmente OCT (acrônimo do inglês: Optical Coherence Tomography), é uma técnica para geração de imagens de seções transversais de meios espalhadores ao comprimento de onda utilizado. A OCT é baseada em interferometria óptica e gera imagens comumente correlacionadas às imagens geradas exames histológicos com a vantagem de ser indolor, não invasiva e não utilizar radiação ionizante. Este estudo dividiu-se em dois objetivos distintos, um refere-se à aplicação de sinais interferométricos de autocorrelação para a formação de imagens de amostras com estruturas complexas. O segundo objetivo foi o estudo das estruturas denominadas de harmônicos e sua aplicação no aumento da resolução axial de um sistema OCT. Com relação à primeira parte, constatou-se que o sinal interferométrico de autocorrelação é muitas vezes ignorado ou descartado pela OCT tradicional. Análises mais profundas da teoria de interferometria, juntamente com alguns estudos anteriores, apontaram para a possibilidade de gerar imagens de maior complexidade morfológica utilizando o sinal de autocorrelação, com a vantagem de se utilizar um arranjo óptico mais simples e também possibilitar imagens estáticas de amostras em movimento axial. Para testar os benefícios e as limitações da técnica de autocorrelação (Au-OCT) foi montado em laboratório e foram realizadas imagens de amostras no repouso e em movimento e confrontadas com imagens geradas no sistema OCT convencional. O sistema de Au-OCT foi capaz de gerar imagens de estruturas diversas (dentes, filmes plásticos entre outros), e apesar de possuir uma qualidade de imagem inferior à OCT, ela apresentou vantagens quando a amostra sofre deslocamentos axiais. Já em relação as características harmônicas, que se apresentam em amostras de alta refletividade óptica como falsas estruturas em imagens OCT, todo um estudo para o entendimento do fenômeno foi desenvolvido. Demonstrou-se também a possibilidade de utilização dessas estruturas para aprimorar a resolução axial diferencial (entre estruturas da própria amostra) através de um estudo numérico e experimental. Para isso padrões dimensionais do tipo degrau foram mensurados e os resultados tratados de acordo com procedimentos metrológicos, mostrando que os harmônicos podem ser utilizados para promover o aumento de resolução axial de um fator de aproximadamente dois. Por fim uma análise crítica sobre os resultados e uma discussão sobre perspectivas dos temas abordados, foram realizada. / Optical Coherence Tomography also largely known as the acronym OCT, is a technique developed to generate transversal sections images of light scattering media. Based on optical interferometry, it provides images correlated to histological images with the advantages of being not invasive, painless besides and does not use ionizing radiation. This study was divided into two separate goals; one refers to the application of interferometric autocorrelation signals for forming images of samples with complex structures. The second objective was the study of structures called harmonics and its application in increasing the axial resolution of an OCT system. Regarding the first part, it was found that the interferometric autocorrelation signal is often ignored or discarded by traditional OCT. Further analysis of the theory of interferometry, along with some previous studies have pointed to the possibility of generating images of greater morphological complexity using the signal autocorrelation, with the advantage of using a simplest optical arrangement and also allow static images of samples in axial movement. To test the benefits and limitations of the autocorrelation technique (Au-OCT) a setup was assembled in and images of samples were performed at rest and in motion and compared with images generated in conventional OCT system. The system Au-OCT was able to generate images of several structures (teeth, plastic films etc.), and despite having a lower image quality to the OCT, it presented advantages when the sample undergoes axial motion. Regarding the harmonic characteristics that are present in samples of high optical reflectivity as false structures in OCT images, a whole study to the understanding of the phenomenon was developed. Also demonstrated the possibility of using these structures to enhance the differential axial resolution (structures between the sample itself) using a numerical and experimental study. Dimensional standards step height like were measured and results handled according to metrological procedures, showing that the harmonics can be used to promote the increase of axial resolution by a factor of about two. Finally a critical analysis of the results and a discussion of perspectives of the topics discussed were performed.
92

A fundamental residue pitch perception bias for tone language speakers

Petitti, Elizabeth Marie 08 April 2016 (has links)
A complex tone composed of only higher-order harmonics typically elicits a pitch percept equivalent to the tone's missing fundamental frequency (f0). When judging the direction of residue pitch change between two such tones, however, listeners may have completely opposite perceptual experiences depending on whether they are biased to perceive changes based on the overall spectrum or the missing f0 (harmonic spacing). Individual differences in residue pitch change judgments are reliable and have been associated with musical experience and functional neuroanatomy. Tone languages put greater pitch processing demands on their speakers than non-tone languages, and we investigated whether these lifelong differences in linguistic pitch processing affect listeners' bias for residue pitch. We asked native tone language speakers and native English speakers to perform a pitch judgment task for two tones with missing fundamental frequencies. Given tone pairs with ambiguous pitch changes, listeners were asked to judge the direction of pitch change, where the direction of their response indicated whether they attended to the overall spectrum (exhibiting a spectral bias) or the missing f0 (exhibiting a fundamental bias). We found that tone language speakers are significantly more likely to perceive pitch changes based on the missing f0 than English speakers. These results suggest that tone-language speakers' privileged experience with linguistic pitch fundamentally tunes their basic auditory processing.
93

Desenvolvimento da técnica de tomografia por coerência óptica de autocorrelação e melhoramento de resolução axial por análise de sinal via transformada de Fourier / Development of autocorrelation optical coherence tomography technique and axial resolution enhancement through Fourier Transform analysis

Raele, Marcus Paulo 18 November 2013 (has links)
Tomografia por Coerência Óptica, ou simplesmente OCT (acrônimo do inglês: Optical Coherence Tomography), é uma técnica para geração de imagens de seções transversais de meios espalhadores ao comprimento de onda utilizado. A OCT é baseada em interferometria óptica e gera imagens comumente correlacionadas às imagens geradas exames histológicos com a vantagem de ser indolor, não invasiva e não utilizar radiação ionizante. Este estudo dividiu-se em dois objetivos distintos, um refere-se à aplicação de sinais interferométricos de autocorrelação para a formação de imagens de amostras com estruturas complexas. O segundo objetivo foi o estudo das estruturas denominadas de harmônicos e sua aplicação no aumento da resolução axial de um sistema OCT. Com relação à primeira parte, constatou-se que o sinal interferométrico de autocorrelação é muitas vezes ignorado ou descartado pela OCT tradicional. Análises mais profundas da teoria de interferometria, juntamente com alguns estudos anteriores, apontaram para a possibilidade de gerar imagens de maior complexidade morfológica utilizando o sinal de autocorrelação, com a vantagem de se utilizar um arranjo óptico mais simples e também possibilitar imagens estáticas de amostras em movimento axial. Para testar os benefícios e as limitações da técnica de autocorrelação (Au-OCT) foi montado em laboratório e foram realizadas imagens de amostras no repouso e em movimento e confrontadas com imagens geradas no sistema OCT convencional. O sistema de Au-OCT foi capaz de gerar imagens de estruturas diversas (dentes, filmes plásticos entre outros), e apesar de possuir uma qualidade de imagem inferior à OCT, ela apresentou vantagens quando a amostra sofre deslocamentos axiais. Já em relação as características harmônicas, que se apresentam em amostras de alta refletividade óptica como falsas estruturas em imagens OCT, todo um estudo para o entendimento do fenômeno foi desenvolvido. Demonstrou-se também a possibilidade de utilização dessas estruturas para aprimorar a resolução axial diferencial (entre estruturas da própria amostra) através de um estudo numérico e experimental. Para isso padrões dimensionais do tipo degrau foram mensurados e os resultados tratados de acordo com procedimentos metrológicos, mostrando que os harmônicos podem ser utilizados para promover o aumento de resolução axial de um fator de aproximadamente dois. Por fim uma análise crítica sobre os resultados e uma discussão sobre perspectivas dos temas abordados, foram realizada. / Optical Coherence Tomography also largely known as the acronym OCT, is a technique developed to generate transversal sections images of light scattering media. Based on optical interferometry, it provides images correlated to histological images with the advantages of being not invasive, painless besides and does not use ionizing radiation. This study was divided into two separate goals; one refers to the application of interferometric autocorrelation signals for forming images of samples with complex structures. The second objective was the study of structures called harmonics and its application in increasing the axial resolution of an OCT system. Regarding the first part, it was found that the interferometric autocorrelation signal is often ignored or discarded by traditional OCT. Further analysis of the theory of interferometry, along with some previous studies have pointed to the possibility of generating images of greater morphological complexity using the signal autocorrelation, with the advantage of using a simplest optical arrangement and also allow static images of samples in axial movement. To test the benefits and limitations of the autocorrelation technique (Au-OCT) a setup was assembled in and images of samples were performed at rest and in motion and compared with images generated in conventional OCT system. The system Au-OCT was able to generate images of several structures (teeth, plastic films etc.), and despite having a lower image quality to the OCT, it presented advantages when the sample undergoes axial motion. Regarding the harmonic characteristics that are present in samples of high optical reflectivity as false structures in OCT images, a whole study to the understanding of the phenomenon was developed. Also demonstrated the possibility of using these structures to enhance the differential axial resolution (structures between the sample itself) using a numerical and experimental study. Dimensional standards step height like were measured and results handled according to metrological procedures, showing that the harmonics can be used to promote the increase of axial resolution by a factor of about two. Finally a critical analysis of the results and a discussion of perspectives of the topics discussed were performed.
94

Estudos e desenvolvimento de métodos baseados em harmônicos esféricos para análise de similaridade estrutural entre ligantes / Study and development of spherical harmonics based methods for similarity ligand analysis

Caires, Fernando Ribeiro 19 October 2016 (has links)
Descritores moleculares são essenciais em muitas aplicações de física e química computacional, como na análise de similaridade entre ligantes baseada em sua estrutura. Harmônicos esféricos têm sido utilizados como descritores da superfície molecular por serem uma forma compacta de descrição geométrica e por possuírem um descritor invariante por rotação. Assim, este trabalho propõe um método de análise de similaridade estrutural entre ligantes no qual se modela a superfície de uma molécula através de uma expansão em harmônicos esféricos realizada pelo programa LIRA. Os coeficientes encontrados são utilizados para percorrer o banco de dados DUD-E, com descritores previamente calculados, utilizando Distância Euclidiana e diversos valores de corte para selecionar compostos mais semelhantes. O potencial do método é avaliado usando o Ultrafast Shape Recognition (USR) como método padrão, pelo fato de ser uma excelente e rápida métrica para análise da similaridade de ligantes. Foram selecionadas 50 moléculas de diferentes tamanhos e composição de forma a representar todos os grupos moleculares presentes na DUD-E. Em seguida, cada molécula foi submetida à busca de similares variando-se valores de corte para o LIRA em que o conjunto de moléculas selecionadas foi comparado com as selecionadas pelo USR através de um processo de classificação binária e criação e interpretação de curvas ROC. Além do benchmarking, foi realizada a análise das componentes principais para determinar quais descritores são os mais importantes e carregam as melhores informações utilizadas na descrição da superfície da molécula. A partir das componentes principais, foi realizado um estudo do uso de funções peso, associando mais importância aos descritores adequados, e a redução da dimensionalidade do banco de dados, seleção de um novo conjunto de autovetores que formam as bases do espaço vetorial e uma nova descrição das moléculas para o novo espaço, no qual cada variação foi avaliada através de um novo benchmarking. O LIRA se mostrou tão rápido quanto o USR e apresentou grande potencial de seleção de moléculas similares, para a maioria das moléculas testadas, pois as curvas ROC apresentaram pontos acima da linha do aleatório. Tanto a redução da dimensionalidade quanto o uso de funções de ponderação agregaram valor à métrica deixando-a mais veloz, no caso da redução da quantidade de descritores, e seletiva, em ambos os casos. Dessa forma, o método proposto se mostrou eficiente em mensurar a similaridade entre ligantes de forma seletiva e rápida utilizando somente informações a respeito da superfície molecular. / Molecular descriptors are essential for many applications in computational chemistry and physics, such as ligand-based similarity searching. Spherical harmonics have previously been suggested as comprehensive descriptors of molecular structure due to their properties, orthonormality and rotationally invariant. Here we proposed a ligand similarity analysis method where molecule\'s surface is modeled by an expansion in Spherical Harmonics, called LIRA, whose coefficient are used to perform a search in DUD-E database, with all descriptors previously calculated, measured by Euclidian Distance and different cutoff\'s values to select similar compounds. Method\'s potential is evaluated against Ultrafast Shape Recognition (USR), due to it is an excellent a fast metric to ligand similarity analysis, in a benchmarking. Fifty molecules are selected varying chemical composition and size to represent all molecular groups of DUD-E. After that, which one was submitted in a search with different values of cutoff for LIRA and the subset selected was compared with the ones selected by USR through binary classification and ROC curves analysis. Beyond benchmarking, it was performed a principal component analysis to identify which are the most valuable coefficient for shape description. Using principal components two other studies are made, weight functions are applied to descriptors, providing more value for those carry more information, and dimensionality reduction, where a subset of eigenvectors are select to form the new basis of the vector space and the new molecule\'s description was made in the new space, which variation was tested in a new benchmarking. Lira showed to be as fast as USR and a big potential to select similar molecules, for the majority of the molecules tested, because ROC curves had points over the random line. Dimensionality reduction and weight functions improved LIRA results raising velocity, due to the use of less descriptors to model molecule\'s surface, and the selection power, for both cases. In summary, the proposed method showed to be an efficient and fast tool for measure similarity between ligands based in molecular shape.
95

Third harmonic microwave generation by superconductors /

Wilfley, Brian Patrick, January 1983 (has links)
Thesis (Ph. D.)--University of California, San Diego, 1983. / Vita. Includes bibliographical references (leaves 156-159).
96

Third harmonic microwave generation by superconductors

Wilfley, Brian Patrick, January 1983 (has links)
Thesis (Ph. D.)--University of California, San Diego, 1983. / Vita. Bibliography: leaves 156-159.
97

Harmonic impedance and harmonic source determination based on field measurements

Nino Hernandez, Edwin Enrique 06 1900 (has links)
Harmonic impedance characterizes the voltage response of a power system when it is subjected to the influence of high-frequency currents. The impedance is a key parameter of a power network and must be known to diagnose power system problems caused by high-frequency disturbances and to design disturbance-mitigation measures. Unfortunately, determining an operating power systems harmonic impedances is very difficult; they must be measured when the system is energized. In fact, how to measure a power systems high-frequency impedances has been a challenging and frequent research topic in the power engineering field. This thesis presents a measurement methodology that can determine the harmonic impedances and sources at both sides of utility-customer interface. This methodology is applicable to single-phase three-wire systems under energized conditions. A potential application of the method is to determine the harmonic contributions of the supply system and its customers at the interface points. / Power Engineering and Power Electronics
98

Design of a Hybrid Active Filter to Suppress Harmonic Distortion in Industrial Facilities

Wnag, Yen-ching 26 July 2010 (has links)
Due to the drastic development of semiconductor, nonlinear loads are widely used in high-power applications, which results in harmonic distortion of current and voltage in the power system. Installation of passive filter is one of the conventional solutions to harmonic distortion. But line impedance, load inductors and/or filter components may result in harmonic resonance, which amplifies the harmonic components, and worsens the harmonic distortion and power quality. This thesis proposed a control algorithm of shunt hybrid active filter to suppress the harmonics and prevent harmonic resonance in industrial facilities. The hybrid active filter is composed of an active filter and a seventh-harmonic frequency tuned passive filter. The hybrid active filter functions as damping conductance for harmonic frequencies. A dynamical tuning control is realized to adjust the damping conductance for maintaining the voltage harmonic distortion. The suppressed harmonic distortion is conformed to the harmonics limitation, such as IEEE std. 519-1992. The capacitors of the hybrid filter sustain fundamental grid voltage and allow the inverter to operate in lower kVA rating. In addition, a dc bus controller was designed to hold the capacitor voltage by controlling the fundamental leading current. The simulations and laboratory results are provided to verify the effectiveness on suppressing harmonic resonance.
99

Modeling, prediction and mitigation of power distribution system voltage distortion caused by nonlinear loads

Wang, Yen-Ju, January 2000 (has links)
Thesis (Ph. D.)--University of Missouri-Columbia, 2000. / Typescript. Vita. Includes bibliographical references (leaves 106-111). Also available on the Internet.
100

Bearing damage detection via wavelet packet decomposition of stator current /

Eren, Levent, January 2002 (has links)
Thesis (Ph. D.)--University of Missouri-Columbia, 2002. / Typescript. Vita. Includes bibliographical references (leaves 96-99). Also available on the Internet.

Page generated in 0.0562 seconds