• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • Tagged with
  • 16
  • 7
  • 7
  • 5
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Logical relations in students' written expression

Moraes, Olinda Martins 15 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Comunicação e Expressão, Programa de Pós-Graduação em Letras, Florianópolis, 1984. / Made available in DSpace on 2012-10-15T22:34:14Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-08T14:59:11Z : No. of bitstreams: 1 278071.pdf: 3744078 bytes, checksum: 2874a455e7a9b2dd5a697eae8053cf9f (MD5)
2

Dinâmica assintótica na 'QED IND.3' /

Boldo, Jose Luis. January 1996 (has links)
Orientador: Bruto Max Pimentel Escobar. / Mestre
3

Dinâmica assintótica na 'QED IND.3'

Boldo, Jose Luis [UNESP] January 1996 (has links) (PDF)
Made available in DSpace on 2016-01-13T13:27:05Z (GMT). No. of bitstreams: 0 Previous issue date: 1996. Added 1 bitstream(s) on 2016-01-13T13:32:24Z : No. of bitstreams: 1 000027527.pdf: 1208975 bytes, checksum: 756634a83ae48f39bd683716761e09e1 (MD5)
4

Desenvolvimento de um sistema de tomografia por coerência óptica no domínio de Fourier sinsível á polarização e sua utilização na determinação das matrizes de Mueller / Development of an Polarization Sensitive Fourier Domain Optical Coherence Tomography and it Utilization on the Mueller Matrix Determination

Raele, Marcus Paulo 02 October 2009 (has links)
Este estudo abordou os aspectos teóricos e experimentais relacionados ao desenvolvimento de um sistema de tomografia por coerência óptica (OCT) no domínio de Fourier sensível à polarização (PS-FD-OCT) e a sua utilização na determinação da Matriz de Mueller (MM-OCT). O estudo iniciou-se com uma revisão bibliográfica que abordou desde os primeiros estudos relacionados à técnica até o estado da arte, bem como o formalismo matemático da interferometria de baixa coerência no domínio espectral e polarização da luz. Realizaram-se estudos baseados em simulação numérica sobre três tipos diferentes de algoritmos, responsáveis pela recuperação do sinal de espalhamento, sendo eles: a Transformada de Fourier Direta; Interpolação e Zero-Filling. Ao fim dessa etapa concluiu-se que o algoritmo Zero-Filling 2N apresentou melhores características quando comparado aos outros algoritmos. Na parte experimental, primeiramente, diferentes arranjos OCT foram montados e medidas realizadas para verificação aspectos relacionados à teoria. Consecutivamente, utilizando uma amostra polimérica, realizaram-se imagens de birrefringência, que permitiram a determinação da birrefringência da amostra quantitativamente. Finalmente, imagens em diferentes estados de polarização foram realizadas, através delas determinou-se as imagens referentes aos elementos das Matrizes de Mueller, que foram analisadas individualmente. / This study approached theoretical and experimental aspects related with the development of a polarization sensitive, Fourier domain, optical coherence tomography system (PS-FD-OCT) and its utilization on the Mueller Matrix determination. This work began with a bibliographic revision, which describes since the early studies to the actual state of the art of the technique. The mathematical formalism of Fourier domain low coherence interferometry and light polarization was performed as well. Studies based on numerical simulations, of three different algorithm types, responsible to recover the scattering profile, were done. The implemented algorithms were: Direct Fourier Transform, Interpolation and Zero-Filling. By the end of the simulation study, was possible to conclude that the algorithm Zero-Filling 2N presented better characteristics when compared with the others. In the experimental part, firstly different OCT setups were assembled and measurements were done in order to verify aspects related with the theory. Then, using a polymeric sample, birefringence images were performed, which allowed determining the sample birefringence quantitatively. Finally, images taken of different polarization states were collected, and through then images related with the Mueller Matrix elements were calculated, which were analyzed individually.
5

Desenvolvimento da técnica de tomografia por coerência óptica de autocorrelação e melhoramento de resolução axial por análise de sinal via transformada de Fourier / Development of autocorrelation optical coherence tomography technique and axial resolution enhancement through Fourier Transform analysis

Marcus Paulo Raele 18 November 2013 (has links)
Tomografia por Coerência Óptica, ou simplesmente OCT (acrônimo do inglês: Optical Coherence Tomography), é uma técnica para geração de imagens de seções transversais de meios espalhadores ao comprimento de onda utilizado. A OCT é baseada em interferometria óptica e gera imagens comumente correlacionadas às imagens geradas exames histológicos com a vantagem de ser indolor, não invasiva e não utilizar radiação ionizante. Este estudo dividiu-se em dois objetivos distintos, um refere-se à aplicação de sinais interferométricos de autocorrelação para a formação de imagens de amostras com estruturas complexas. O segundo objetivo foi o estudo das estruturas denominadas de harmônicos e sua aplicação no aumento da resolução axial de um sistema OCT. Com relação à primeira parte, constatou-se que o sinal interferométrico de autocorrelação é muitas vezes ignorado ou descartado pela OCT tradicional. Análises mais profundas da teoria de interferometria, juntamente com alguns estudos anteriores, apontaram para a possibilidade de gerar imagens de maior complexidade morfológica utilizando o sinal de autocorrelação, com a vantagem de se utilizar um arranjo óptico mais simples e também possibilitar imagens estáticas de amostras em movimento axial. Para testar os benefícios e as limitações da técnica de autocorrelação (Au-OCT) foi montado em laboratório e foram realizadas imagens de amostras no repouso e em movimento e confrontadas com imagens geradas no sistema OCT convencional. O sistema de Au-OCT foi capaz de gerar imagens de estruturas diversas (dentes, filmes plásticos entre outros), e apesar de possuir uma qualidade de imagem inferior à OCT, ela apresentou vantagens quando a amostra sofre deslocamentos axiais. Já em relação as características harmônicas, que se apresentam em amostras de alta refletividade óptica como falsas estruturas em imagens OCT, todo um estudo para o entendimento do fenômeno foi desenvolvido. Demonstrou-se também a possibilidade de utilização dessas estruturas para aprimorar a resolução axial diferencial (entre estruturas da própria amostra) através de um estudo numérico e experimental. Para isso padrões dimensionais do tipo degrau foram mensurados e os resultados tratados de acordo com procedimentos metrológicos, mostrando que os harmônicos podem ser utilizados para promover o aumento de resolução axial de um fator de aproximadamente dois. Por fim uma análise crítica sobre os resultados e uma discussão sobre perspectivas dos temas abordados, foram realizada. / Optical Coherence Tomography also largely known as the acronym OCT, is a technique developed to generate transversal sections images of light scattering media. Based on optical interferometry, it provides images correlated to histological images with the advantages of being not invasive, painless besides and does not use ionizing radiation. This study was divided into two separate goals; one refers to the application of interferometric autocorrelation signals for forming images of samples with complex structures. The second objective was the study of structures called harmonics and its application in increasing the axial resolution of an OCT system. Regarding the first part, it was found that the interferometric autocorrelation signal is often ignored or discarded by traditional OCT. Further analysis of the theory of interferometry, along with some previous studies have pointed to the possibility of generating images of greater morphological complexity using the signal autocorrelation, with the advantage of using a simplest optical arrangement and also allow static images of samples in axial movement. To test the benefits and limitations of the autocorrelation technique (Au-OCT) a setup was assembled in and images of samples were performed at rest and in motion and compared with images generated in conventional OCT system. The system Au-OCT was able to generate images of several structures (teeth, plastic films etc.), and despite having a lower image quality to the OCT, it presented advantages when the sample undergoes axial motion. Regarding the harmonic characteristics that are present in samples of high optical reflectivity as false structures in OCT images, a whole study to the understanding of the phenomenon was developed. Also demonstrated the possibility of using these structures to enhance the differential axial resolution (structures between the sample itself) using a numerical and experimental study. Dimensional standards step height like were measured and results handled according to metrological procedures, showing that the harmonics can be used to promote the increase of axial resolution by a factor of about two. Finally a critical analysis of the results and a discussion of perspectives of the topics discussed were performed.
6

Desenvolvimento da técnica de tomografia por coerência óptica de autocorrelação e melhoramento de resolução axial por análise de sinal via transformada de Fourier / Development of autocorrelation optical coherence tomography technique and axial resolution enhancement through Fourier Transform analysis

Raele, Marcus Paulo 18 November 2013 (has links)
Tomografia por Coerência Óptica, ou simplesmente OCT (acrônimo do inglês: Optical Coherence Tomography), é uma técnica para geração de imagens de seções transversais de meios espalhadores ao comprimento de onda utilizado. A OCT é baseada em interferometria óptica e gera imagens comumente correlacionadas às imagens geradas exames histológicos com a vantagem de ser indolor, não invasiva e não utilizar radiação ionizante. Este estudo dividiu-se em dois objetivos distintos, um refere-se à aplicação de sinais interferométricos de autocorrelação para a formação de imagens de amostras com estruturas complexas. O segundo objetivo foi o estudo das estruturas denominadas de harmônicos e sua aplicação no aumento da resolução axial de um sistema OCT. Com relação à primeira parte, constatou-se que o sinal interferométrico de autocorrelação é muitas vezes ignorado ou descartado pela OCT tradicional. Análises mais profundas da teoria de interferometria, juntamente com alguns estudos anteriores, apontaram para a possibilidade de gerar imagens de maior complexidade morfológica utilizando o sinal de autocorrelação, com a vantagem de se utilizar um arranjo óptico mais simples e também possibilitar imagens estáticas de amostras em movimento axial. Para testar os benefícios e as limitações da técnica de autocorrelação (Au-OCT) foi montado em laboratório e foram realizadas imagens de amostras no repouso e em movimento e confrontadas com imagens geradas no sistema OCT convencional. O sistema de Au-OCT foi capaz de gerar imagens de estruturas diversas (dentes, filmes plásticos entre outros), e apesar de possuir uma qualidade de imagem inferior à OCT, ela apresentou vantagens quando a amostra sofre deslocamentos axiais. Já em relação as características harmônicas, que se apresentam em amostras de alta refletividade óptica como falsas estruturas em imagens OCT, todo um estudo para o entendimento do fenômeno foi desenvolvido. Demonstrou-se também a possibilidade de utilização dessas estruturas para aprimorar a resolução axial diferencial (entre estruturas da própria amostra) através de um estudo numérico e experimental. Para isso padrões dimensionais do tipo degrau foram mensurados e os resultados tratados de acordo com procedimentos metrológicos, mostrando que os harmônicos podem ser utilizados para promover o aumento de resolução axial de um fator de aproximadamente dois. Por fim uma análise crítica sobre os resultados e uma discussão sobre perspectivas dos temas abordados, foram realizada. / Optical Coherence Tomography also largely known as the acronym OCT, is a technique developed to generate transversal sections images of light scattering media. Based on optical interferometry, it provides images correlated to histological images with the advantages of being not invasive, painless besides and does not use ionizing radiation. This study was divided into two separate goals; one refers to the application of interferometric autocorrelation signals for forming images of samples with complex structures. The second objective was the study of structures called harmonics and its application in increasing the axial resolution of an OCT system. Regarding the first part, it was found that the interferometric autocorrelation signal is often ignored or discarded by traditional OCT. Further analysis of the theory of interferometry, along with some previous studies have pointed to the possibility of generating images of greater morphological complexity using the signal autocorrelation, with the advantage of using a simplest optical arrangement and also allow static images of samples in axial movement. To test the benefits and limitations of the autocorrelation technique (Au-OCT) a setup was assembled in and images of samples were performed at rest and in motion and compared with images generated in conventional OCT system. The system Au-OCT was able to generate images of several structures (teeth, plastic films etc.), and despite having a lower image quality to the OCT, it presented advantages when the sample undergoes axial motion. Regarding the harmonic characteristics that are present in samples of high optical reflectivity as false structures in OCT images, a whole study to the understanding of the phenomenon was developed. Also demonstrated the possibility of using these structures to enhance the differential axial resolution (structures between the sample itself) using a numerical and experimental study. Dimensional standards step height like were measured and results handled according to metrological procedures, showing that the harmonics can be used to promote the increase of axial resolution by a factor of about two. Finally a critical analysis of the results and a discussion of perspectives of the topics discussed were performed.
7

Desenvolvimento de um sistema de tomografia por coerência óptica no domínio de Fourier sinsível á polarização e sua utilização na determinação das matrizes de Mueller / Development of an Polarization Sensitive Fourier Domain Optical Coherence Tomography and it Utilization on the Mueller Matrix Determination

Marcus Paulo Raele 02 October 2009 (has links)
Este estudo abordou os aspectos teóricos e experimentais relacionados ao desenvolvimento de um sistema de tomografia por coerência óptica (OCT) no domínio de Fourier sensível à polarização (PS-FD-OCT) e a sua utilização na determinação da Matriz de Mueller (MM-OCT). O estudo iniciou-se com uma revisão bibliográfica que abordou desde os primeiros estudos relacionados à técnica até o estado da arte, bem como o formalismo matemático da interferometria de baixa coerência no domínio espectral e polarização da luz. Realizaram-se estudos baseados em simulação numérica sobre três tipos diferentes de algoritmos, responsáveis pela recuperação do sinal de espalhamento, sendo eles: a Transformada de Fourier Direta; Interpolação e Zero-Filling. Ao fim dessa etapa concluiu-se que o algoritmo Zero-Filling 2N apresentou melhores características quando comparado aos outros algoritmos. Na parte experimental, primeiramente, diferentes arranjos OCT foram montados e medidas realizadas para verificação aspectos relacionados à teoria. Consecutivamente, utilizando uma amostra polimérica, realizaram-se imagens de birrefringência, que permitiram a determinação da birrefringência da amostra quantitativamente. Finalmente, imagens em diferentes estados de polarização foram realizadas, através delas determinou-se as imagens referentes aos elementos das Matrizes de Mueller, que foram analisadas individualmente. / This study approached theoretical and experimental aspects related with the development of a polarization sensitive, Fourier domain, optical coherence tomography system (PS-FD-OCT) and its utilization on the Mueller Matrix determination. This work began with a bibliographic revision, which describes since the early studies to the actual state of the art of the technique. The mathematical formalism of Fourier domain low coherence interferometry and light polarization was performed as well. Studies based on numerical simulations, of three different algorithm types, responsible to recover the scattering profile, were done. The implemented algorithms were: Direct Fourier Transform, Interpolation and Zero-Filling. By the end of the simulation study, was possible to conclude that the algorithm Zero-Filling 2N presented better characteristics when compared with the others. In the experimental part, firstly different OCT setups were assembled and measurements were done in order to verify aspects related with the theory. Then, using a polymeric sample, birefringence images were performed, which allowed determining the sample birefringence quantitatively. Finally, images taken of different polarization states were collected, and through then images related with the Mueller Matrix elements were calculated, which were analyzed individually.
8

[en] METROLOGICAL RELIABILITY OF OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICAL APPLICATIONS / [pt] CONFIABILIDADE METROLÓGICA DA TOMOGRAFIA POR COERÊNCIA ÓPTICA EM APLICAÇÕES BIOMÉDICAS

CAROLINA MOREIRA GOLONI MARQUES 14 April 2014 (has links)
[pt] A Tomografia por Coerência Óptica (OCT) vem sendo utilizada desde a década de 1990 em diversas áreas do campo biomédico, uma biópsia óptica com importantes perspectivas como ferramenta diagnóstica para caracterização quantitativa de estruturas teciduais.No presente trabalho é realizado estudo dos parâmetros para avaliação de conformidade dos equipamentos optoeletrônicos para aplicação biomédica como Laser, IPL(Luz Pulsada Intensa) e OCT, objetivando a identificação dos itens cuja avaliação é necessária como requisito em futura norma específica para equipamentos de Tomografia por Coerência Óptica. Além dos parâmetros metrológicos requeridos na norma particular para equipamentos a Laser, e alguns dos parâmetros da norma para IPL, foram identificados outros parâmetros metrológicos específicos para avaliação de equipamentos de OCT, considerando sua aplicação biomédica, como comprimento de coerência, resolução axial e resolução transversal. Considerando a possibilidade de elaboração futura de norma específica para OCT, para alguns dos parâmetros identificados, recomendou-se o requisito de medição e, para outros, somente a inclusão da informação nos documentos acompanhantes. Dentre os parâmetros cujo requisito de medição foi recomendado para equipamentos de OCT são: potência da emissão eletromagnética, comprimento de onda central, concentricidade entre os feixes de trabalho e de mira, diâmetro e divergência do feixe de trabalho, duração de um pulso, número de pulsos em um trem de pulsos e irradiância espectral. / [en] Optical Coherence Tomography has been proving to be an efficient diagnostics technique for imaging in vivo tissues, an optical biopsy with important perspectives as a diagnostics tool for quantitative characterization of tissue structures.The present work studies the parameters conformity evaluation of optoelectronics equipment for biomedical applications like Laser, IPL (Intense Pulsed Light), and OCT, targeting the identification of items which are necessary as a requirement to develop a future specific standard for Optical Coherence Tomography equipments. Beside the metrological parameters required by the particular standard for Laser and IPL equipment, specific parameters necessary for OCT’s evaluation have been identified, regarding its biomedical application. For some parameters identified, measurement requisite has been recommended, and for others, only the information on the accompanying documents. Among the parameters required for measurement, highlights for: electromagnetic emission power, measurement uncertainty of incident power, coherence length, work beam diameter and divergence, pulse duration and spectral irradiance.
9

[en] HERE ARE YOU: ASTROLOGY AS A SYSTEM OF COHERENCE IN THE CONSTRUCTION OF SMALL AND LARGE NARRATIVES / [pt] EIS VOCÊ: A ASTROLOGIA COMO SISTEMA DE COERÊNCIA NA CONSTRUÇÃO DE PEQUENAS E GRANDES NARRATIVAS

MILENA LEPSCH DA COSTA 16 August 2018 (has links)
[pt] Na modernidade, em que as relações são definidas como líquidas (BAUMAN, 2005), este trabalho procura entender, a partir da análise narrativa (BASTOS; BIAR, 2015), a popularidade/produtividade do sistema de crença da astrologia, especialmente na construção de um discurso essencializante sobre a identidade. Para isso, apresento 22 entrevistas de pesquisa (MISHLER, 1986) sobre o tema, realizadas com estudantes da PUC-Rio no período de 2016 a 2017 nas quais emerge uma considerável quantidade de pequenas histórias e histórias de vida (LINDE, 1993), aqui analisadas qualitativa e interpretativamente. Compreendo a narrativa como um importante instrumento para a construção de sentido no mundo social (BASTOS; BIAR, 2015) e para a formação de identidades autobiográficas (BRUNER, 1990; MOITA LOPES, 2001). Nestes termos, observo quais estratégias discursivas os entrevistados utilizam-se para construir histórias sobre si/outros, esforçando-se para apresentarem-se da melhor forma possível neste teatro (GOFFMAN, 1980, 2002 (1959), 2011 (1967), 2013 (1979)) que é a entrevista de pesquisa. Nota-se que muitas dessas histórias são costuradas a partir do sistema de coerência da astrologia (LINDE,1993). Isto é, os entrevistados constroem accounts (DE FINA, 2009) ou relações de causa e efeito, com o objetivo de reivindicar certo assujeitamento (BLOCK, 2012) no discurso, especialmente para comportamentos considerados socialmente negativos. Desse modo, os signos, ao livrarem seus narradores de agência, atuam no trabalho de face (GOFFMAN, 2011(1967)), colaborando para uma apresentação favorável dos entrevistados. / [en] In modernity, where relationships are defined as liquid (BAUMAN, 2005, 2006), this paper seeks from the standpoint of narrative analysis (BASTOS; BIAR, 2015), the popularity / productivity of astrology, especially in the construction of an essentializing discourse on identity. For this, I present 22 research interviews (MISHLER, 1986) on the subject, carried out with students from PUC- Rio from 2016 to 2017, in which a considerable amount of small histories and life stories emerge (LINDE, 1993), analyzed here qualitatively and interpretatively. I understand narrative as an important tool for the construction of meaning in the social world (BASTOS; BIAR, 2015) and for the formation of autobiographical identities (BRUNER, 1990; MOITA LOPES, 2001). In these terms, I observe which discursive strategies the interviewees use to build stories about themselves / others, striving to present themselves in the best possible way in this theater (GOFFMAN, 2002 (1959), 2011 (1967), 2013 (1979)), which is the research interview. It is noted that many of these stories are stitched from the system of coherence of astrology (LINDE, 1993). That is, the interviewees construct accounts (DE FINA, 2009) or cause-and-effect relationships, with the purpose of claiming some assumption (BLOCK, 2012) in discourse, especially for behaviors considered socially negative. In this way, signs, in relieving narrators of agency, act in the face work (GOFFMAN, 2011(1967)), collaborating for the favorable presentation of the interviewees.
10

Correlação entre estrutura anatômica e função visual em buraco macular e membrana epirretiniana. Efeitos da vitrectomia com peeling da membrana limitante interna / The correlation between retinal function and structure in macular hole before and after macular peeling

Perches, Ana Claudia Brancato De Lucca 18 October 2013 (has links)
Objetivos: Avaliar a função e estrutura da retina de pacientes com membrana epirretiniana (MER) ou buraco macular (BM) antes e após a cirurgia, e determinar suas relações e os valores preditivos para a acuidade visual após tratamento com vitrectomia associada a peeling da membrana limitante interna. Casuística e Métodos: Foram incluídos 51 olhos de 50 pacientes com indicação de tratamento cirúrgico de MER ou BM idiopáticos. Foi realizada avaliação oftalmológica completa, incluindo melhor acuidade visual corrigida (MAVC) no pré-operatório e nas semanas 1, 3, 8, 24 e 48 após a cirurgia, enquanto que eletrorretinografia multifocal (mfERG) e tomografia de coerência óptica (OCT) foram realizadas antes da cirurgia e dois e doze meses após o procedimento. Os resultados da mfERG serão apresentados na forma da razão entre os valores encontrados nos dois anéis centrais, normalizados pelas médias dos três anéis periféricos (denominada razão P1), para minimizar a variabilidade interpessoal desse teste e ressaltar as alterações encontradas nos anéis centrais. A OCT foi usada para calcular o quociente entre medidas da altura e base do BM (IBM). Resultados: Quarenta e cinco pacientes (46 olhos; n = 30 BM e 16 MER) completaram as 48 semanas de seguimento. No pré-operatório, a média ± SE da MAVC (logMAR) para os grupos BM e MER, respectivamente, foi: 0,93 ± 0,22 (20/170; ou 0,12 decimal) e 0,58 ± 0,11 (20/76; ou 0,26 decimal), com melhora significativa após 48 semanas de seguimento (média ± EP da diferença entre as acuidades visuais medidas em logMAR em 48 semanas e a basal) -0,25 ± 0,07 para o grupo BM e -0,29 ± 0,06 para o grupo MER. O mfERG mostrou-se alterado antes da cirurgia para BM, com melhora da razão P1 após a cirurgia. Para o BM, houve correlação entre a razão P1 no pré-operatório e o ganho da MAVC na semana 8 após a cirurgia (r = -0,42; p = 0,033), mas essa correlação não foi observada para o grupo MER. Também não houve correlação entre o IBM e a acuidade visual após a cirurgia. Conclusões: Os resultados indicam que pacientes com BM apresentando mfERG com baixa razão P1 têm menor probabilidade de ganho de visão após a cirurgia, mas essa afirmativa não é válida para a MER. / Purpose: To evaluate retinal structure and function in eyes with macular hole (MH) or epiretinal membrane (ERM) before and after pars-plana vitrectomy with internal limitant membrane (ILM) peeling, to determine function/structural interrelations and predictive values of postoperative visual acuity. Casuistic and Methods: Fifty-one eyes of 50 patients with idiopathic MH or ERM were included. Comprehensive ophthalmologic evaluation including best-corrected visual acuity (BCVA) was performe date baseline, 1, 3, 8, 24 e 48 weeks after surgery, while optical coherence tomography (OCT) and multifocal ERG was performed before and at 2 and 12 months after surgery. mfERG results are show using the ratio between the amplitude averages of the 2 central rings and the 3 peripheral rings (P1 ratio) and OCT was used to calculate the macular hole index (MHI) defined by the quotient between hole height/base. Results: Forty-five patients (46 eyes; n = 30 MH and 16 ERM) finished follow-up. Mean ± SE (logMAR) preoperative BCVA was 0.93 ± 0.22 and 0.58 ± 0.11 for MH and ERM respectively, and improved in -0.25 ± 0.07 logMAR for MH and -0.29 ± 0.06 logMAR for ERM. mfERG P1 ratio was reduced in BM, and increased significantly after surgery. There was significant correlation between preoperative P1 ratio and BCVA gainat week 8 for MH group (r = -0,42; p = 0,033), but not for ERM group. There was no correlation between preoperative MHI and postoperative BCVA. Conclusion: This data indicates that patients with MH and poor mfERG amplitudes have worse prognoses for BCVA improvement, but does not apply for ERM.

Page generated in 0.0619 seconds