• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Incidência de infecção nosocomial causada por vírus respiratório, em uma unidade de cuidado intensivo e semi-intensivo neonatal

Gadelha, Carolina Strauss Estevez 30 August 2012 (has links)
Made available in DSpace on 2016-12-23T13:56:13Z (GMT). No. of bitstreams: 1 Carolina Strauss Estevez Gadelha.pdf: 1231654 bytes, checksum: 076b56febe691cf83fd0c9fe588b62da (MD5) Previous issue date: 2012-08-30 / The newborn infant, especially one born before term, is more susceptible to infections. There are few published data on nosocomial viral infections in the neonatal period and those have conflicting results. Aims: to determine the incidence of nosocomial viral infection in newborn infants hospitalized in an intensive care unit (ICU) and semi-intensive care unit, at Vitória, ES, and to carry out clinical surveillance for the emergence of symptoms suggestive of that viral infection. Methods: this is a 13-month prospective cohort study held conducted from November 2010 to December 2011. All newborn infants hospitalized in the neonatal ICU of the Cassiano Antônio Morais University Hospital (HUCAM) throughout the study were subjected to clinical monitoring and weekly collection of nasopharyngeal secretion (NPS) up to patient discharge. Fifteen different viruses were searched through indirect immunofluorescence (RIFI) and polymerase chain reaction (PCR) in the multiplex format. Results: one hundred and fourteen newborn infants were included in the study, of which were obtained 424 samples of NPS. All samples were tested by IIFR and 51 of them by PCR. Twenty-six (22.8%) newborn infants showed clinical suspicion of nosocomial viral infection. In nine patients was detected some respiratory virus, being respiratory syncytial virus (RSV) in four (3.5%), Rhinoviruses (HRV) in three (2.6%) and Influenza A virus (FLU) in two (1.7%). Two patients were asymptomatic. The incidence of nosocomial viral infection was 7.8%. We found a weak association between the clinical suspicion of viral infection and detection of the virus in laboratory. Conclusions: the noted incidence was compatible with the characteristics of the studied unit and the result of an ongoing effort to prophylaxis and continuing education. Considering the difficulty of accurate clinical diagnosis in neonatal period, we emphasize the importance of laboratory diagnosis of these viruses in that period / O neonato, especialmente aquele nascido antes do termo, é mais suscetível às infecções. Existem poucos dados publicados sobre as infecções virais nosocomiais no período neonatal e estes apresentam resultados discordantes. Objetivos: Determinar a incidência de infecção viral nosocomial em neonatos internados em uma unidade de terapia intensiva (UTI) e semi-intensiva, em Vitória, ES e realizar vigilância clínica quanto ao aparecimento de sintomas sugestivos dessa infecção viral. Métodos: Trata-se de um estudo de coorte, prospectivo, com duração de 13 meses, realizado de novembro de 2010 a dezembro de 2011. Todos os neonatos internados na UTI neonatal do Hospital Universitário Cassiano Antônio Morais (HUCAM) no período do estudo foram submetidos a acompanhamento clínico e coleta semanal de secreção de nasofaringe (SNF), até a alta da unidade. Foram pesquisados 15 diferentes vírus por meio de imunofluorescência indireta (RIFI) e Reação em cadeia da polimerase (PCR) no formato multiplex. Resultados: Cento e quatorze neonatos foram incluídos, sendo deles obtidas 424 amostras de Secreção de nasofaringe (SNF). Todas as amostras foram testadas por RIFI e 51 por PCR. Vinte e seis neonatos (22,8%) apresentaram suspeita clínica de infecção viral nosocomial. Em nove pacientes foi detectado algum vírus respiratório, sendo Vírus sincicial respiratório (VSR) em quatro (3,5%), Rinovírus (HRV) em três (2,6%) e Influenza A (FLU A) em dois (1,7%). Dois pacientes estavam assintomáticos. A incidência de infecção viral nosocomial foi de 7,8%. Identificou-se uma fraca associação entre a suspeita clínica de infecção viral e a detecção do vírus laboratorialmente. Conclusões: A incidência encontrada foi compatível com as características da unidade estudada e resultado de um esforço permanente para profilaxia e educação continuada. Considerando a dificuldade de diagnóstico clínico preciso no período neonatal, ressaltamos a importância do diagnóstico laboratorial dessas viroses nesse período
2

Banho de clorexidina para prevenção de colonização e infecção por micro-organismos multirresistentes na unidade de transplante de células tronco e hematopoiéticas / Chlorhexidine daily bath for prevention multiresistant microorganisms (MR) colonization and infection in Hematopoietic Stem Cell Transplant (HSCT) unit in a nine years period

Mendes, Elisa Donalisio Teixeira 25 February 2016 (has links)
Introdução: Infecções relacionadas à assistência de saúde (IRAS) representam hoje um dos principais desafios da qualidade do cuidado do paciente, principalmente em pacientes submetido a transplante de células tronco e hematopoiéticas (TCTH) O banho diário com a clorexidina (CHG) degermante a 2% tem sido proposto principalmente em unidades de terapia intensivas (UTIs) para diminuir a colonização bacteriana do paciente e assim diminuir IRAS. O objetivo deste estudo foi avaliar o impacto do banho com CHG degermante a 2% em unidade de internação de TCTH na incidência de infecção e colonização por patógenos multirresistentes e ainda avaliar seu impacto na sensibilidade das bactérias ao antisséptico. Métodos: Foi realizado um estudo quasi-experimental, com duração de 9 anos, com início em janeiro/2005 até dezembro/2013. A intervenção foi iniciada em agosto de 2009, sendo que os períodos pré e pós-intervenção tiveram duração de 4,5 anos. As taxas de IRAS, infecção por gram-negativos multirresistentes e infecção e colonização por enterococo resistente a vancomicina (VRE) foram avaliadas através de série temporal, para estudar o impacto da intervenção. As concentrações inibitórias mínimas (CIM) das bactérias para a CHG com e sem o inibidor de bomba de efluxo (CCCP) foram avaliadas nos dois períodos. Os genes de resistência a CHG foram estudados por meio da PCR e a clonalidade dos isolados por eletroforese em campo pulsátil. Resultados: Foi observada redução significativa na incidência de infecção e colonização de VRE na unidade no período pós-intervenção (p: 0,001). Essa taxa permaneceu estável em outras UTIs clínicas do hospital. Contudo as taxas de infecção por Gram negativos multirresistentes aumentou nos últimos anos na unidade. Não ocorreu diminuição na taxa de IRAS na unidade. As CIMs testadas de CHG aumentaram nas amostras de VRE e K. pneumoniae após o período de exposição ao antisséptico, com queda importante da CIM após o uso do CCCP, revelando ser a bomba de efluxo, um importante mecanismo de resistência à CHG. As amostras de A. baumannii e P. aeruginosa não apresentaram aumento da CIM após período de exposição à clorexidina. As bombas de efluxo Ade A, B e C estiveram presentes na maioria dos A. baumannii do grupo controle (66%). A bomba cepA foi encontrada em 67% de todas as K. pneumoniae testadas e em 44,5% das P. aeruginosas do grupo pré intervenção. Observamos uma relação positiva entre a presença da CepA nas amostras de K. pneumoniae e a resposta ao CCCP: de todas as 49 amostras CepA positivas 67,3% obtiveram redução do seu MIC em 4 diluições após adição do CCCP. A avaliação de clonalidade demonstrou padrão policlonal das amostras de VRE, K. pneumoniae e A. baumannii avaliadas. Em relação às amostras de P. aeruginosa foi observado que no período pós-intervenção ocorreu predominância de um clone com > 80% semelhança em 10 das 22 amostras avaliadas pelo dendrograma. Conclusões: O banho de clorexidina teve impacto na redução da incidência de infecção e colonização por VRE na unidade de TCTH, e não teve o mesmo impacto nas bactérias gram-negativas. Os mecanismos moleculares de resistência à clorexidina estão intimamente ligados à presença de bomba de efluxo, sendo provavelmente o principal mecanismo de resistência e tolerância das bactérias ao antisséptico / Background and objectives: Daily skin cleansing with 2% chlorhexidine gluconate (CHG) in patients in intensive care unit is associated with reduction in incidence of multiresistant microorganisms (MR). Data in Hematological Steam Cell Transplant (HSCT), however, is scarce, and studies addressing the impact of this intervention in this population are needed. The aim of this study was to evaluate the effectiveness of daily bathing with CHG in reducing infection and colonization by MR (vancomycin resistance Enterococcus -VRE, P. aeruginosa, A. baumannii and K. pneumoniae) in HSCT patients and also evaluated the antiseptic susceptibility comparing pre and post intervention period. Methods: We perform a 9 year pre and post interventional study. In August 2009, was implemented daily bathing with CHG, replacing regular soap in all patients in a 12 beds HSCT ward, located in a tertiary reference hospital in Sao Paulo/Brazil. The goal of the intervention was decreasing MR prevalence in the unit. Therefore we evaluated the incidence-density (ID=cases/1000 patient days) of MR colonization and infection in periods of 4.5 years before and 4.5 years after intervention. Minimum inhibitory concentration (MIC) values were tested for CHG using Muller-Hinton agar dilution in MR strains isolated pre and post intervention period. The behavior of the strains after introduction of an efflux pump inhibitor (CCCP) was also assessed to study the importance of this resistance mechanism in relation to CHG. Statistical analyzes were performed using time-series analyses in ARIMA model, and SPSS program was used. P < 0.05 was considered statistically significant. Results: A significant reduction in infection and colonization VRE incidence was observed in post-intervention period (p 0.001). The opposite occurred with gran-negative infection and colonization rates, which had increased in recent years at the unit (p < 0.001). Rates of blood stream infection (BSI) remained stable in both periods. The VRE and K. pneumoniae strains showed two fold MIC 50 increase in in the post exposure period. However the strains of P. aeruginosa and A. baumannii had no MIC 50 increase after antiseptic exposure period. All MIC 50 strains was significant reduced after using the efflux pump inhibitor (CCCP) Conclusions: The CHG bath showed to be effective in reducing VRE infection and colonization in HSCT unit, and corroborating the literature the same impact was not taken in gram-negative bacteria. The unit microbiota has been impacted by the CHG massive use, however the increase MIC seemed not influence the efficacy of intervention in VRE cases. Molecular mechanisms of resistance to chlorhexidine are closely linked to the presence of efflux pump
3

Avaliação dos parâmetros físicos, químicos e microbiológicos do ar na unidade de terapia intensiva neonatal e no centro cirúrgico do Hospital Universitário Prof. Dr. Alberto Antunes HUPAA, Maceió-AL

Rita, Krystianelly Patrícia Pedrosa Santa 03 September 2010 (has links)
Intensive care units (ICU) and Surgical Center are noteworthy environments, because patients with poor health that frequent these places are subjected to acquire infections from the air of these environments. The aim of this study was to evaluate the air quality during the dry and rainy seasons of air-conditioned rooms of the NICU, neonatal intensive care unit, (A, B and C) , surgical center and exterior area at the University Hospital HUPAA/UFAL, Maceió-AL, for parameters recommended by ANVISA, and identify the mycoflora found and quantify the bacteria in the air. A number of 22 points of collects were performed, totaling 220 samples of air taken through the methodology specified by ANVISA s No. 9 Resolution, which consists in the definition of the parameters of bioaerosol, CO2, temperature, relative humidity, air velocity and aerialdispersoids. Macro and microscopic features were compared in order to identify the mycoflora and yeasts were identified by PCR with species-specific primers. From the 3.839 fungal colony forming units (CFU) isolated, 1.085 CFU were identified as belonging to 21 genera distributed among 63 species. Mycelia Sterilia with 121 CFU (11.1%) and Cladosporium cladosporioides with 78 CFU (7.2%) were the most frequent species in rainy season. Among the yeast species, Candida parapsilosis and C. tropicalis had the biggest frequency, both with four isolates corresponding to 4.7% each. The means were statistically significant for the parameters CO2, temperature, humidity and aerialdispersoids, not being significant for the air speed parameter. The observed values shows that the environments tested in the hospital were out of compliance for most of the parameters recommended by health surveillance in relation to the indoor air quality. Corrective measures are needed to remedy the possible sources of contamination in hospitals in order to comply with the four technical standards recommended by the National Agency for Sanitary Vigilance, contributing to the reduction of the levels of hospital infection, and the number of deaths related to it. / Fundação de Amparo a Pesquisa do Estado de Alagoas / As UTI s e o centro cirúrgico são ambientes hospitalares que merecem destaque, pois os pacientes nestes locais estão sujeitos a adquirir infecções provenientes do ar desses ambientes por apresentarem a saúde debilitada. O objetivo deste trabalho foi avaliar a qualidade do ar durante os períodos seco e chuvoso dos ambientes internos climatizados A, B e C da UTN, do centro cirúrgico e do ponto externo do Hospital Universitário HUPAA/UFAL, Maceió-AL, com relação aos parâmetros recomendados pela ANVISA, além de identificar a microbiota fúngica e quantificar as bactérias presentes no ar. Foram realizadas 22 coletas, totalizando 220 amostragens de ar realizadas através da metodologia indicada pela Resolução nº 9 da ANVISA que consiste na determinação dos parâmetros de bioaerossóis, CO2, temperatura, umidade relativa, velocidade do ar e aerodispersóides. Para identificação dos fungos filamentosos foram comparadas as características macro e microscópicas e as leveduras foram identificadas através da técnica de PCR com iniciadores espécie-específicos. Das 3.839 UFC fúngicas isoladas foram identificadas 1.085 UFC pertencentes a 21 gêneros distribuídos em 63 espécies, sendo Mycelia Sterilia com 121 (11,1%) UFC e Cladosporium cladosporioides com 78 (7,2%) UFC as espécies mais freqüentes no período chuvoso. Entre as leveduras, Candida parapsilosis e C. tropicalis foram as mais ocorrentes, ambas com quatro isolados correspondendo a 4,7% cada. As médias foram estatisticamente significativas para os parâmetros CO2, temperatura, umidade relativa, aerodispersóides e bioaerossóis, não sendo significativas para o parâmetro velocidade do ar. Os valores observados demonstram que os ambientes hospitalares estudados estavam fora de conformidade para maioria dos parâmetros recomendados pela vigilância sanitária em relação à qualidade do ar de interiores. Medidas corretivas são necessárias para remediar as possíveis fontes de contaminação nas unidades hospitalares de forma a atender as quatro normas técnicas preconizadas pela Agência Nacional de Vigilância Sanitária, contribuindo para minimizar os níveis de infecção hospitalar e o número de óbitos a esta relacionados.
4

Banho de clorexidina para prevenção de colonização e infecção por micro-organismos multirresistentes na unidade de transplante de células tronco e hematopoiéticas / Chlorhexidine daily bath for prevention multiresistant microorganisms (MR) colonization and infection in Hematopoietic Stem Cell Transplant (HSCT) unit in a nine years period

Elisa Donalisio Teixeira Mendes 25 February 2016 (has links)
Introdução: Infecções relacionadas à assistência de saúde (IRAS) representam hoje um dos principais desafios da qualidade do cuidado do paciente, principalmente em pacientes submetido a transplante de células tronco e hematopoiéticas (TCTH) O banho diário com a clorexidina (CHG) degermante a 2% tem sido proposto principalmente em unidades de terapia intensivas (UTIs) para diminuir a colonização bacteriana do paciente e assim diminuir IRAS. O objetivo deste estudo foi avaliar o impacto do banho com CHG degermante a 2% em unidade de internação de TCTH na incidência de infecção e colonização por patógenos multirresistentes e ainda avaliar seu impacto na sensibilidade das bactérias ao antisséptico. Métodos: Foi realizado um estudo quasi-experimental, com duração de 9 anos, com início em janeiro/2005 até dezembro/2013. A intervenção foi iniciada em agosto de 2009, sendo que os períodos pré e pós-intervenção tiveram duração de 4,5 anos. As taxas de IRAS, infecção por gram-negativos multirresistentes e infecção e colonização por enterococo resistente a vancomicina (VRE) foram avaliadas através de série temporal, para estudar o impacto da intervenção. As concentrações inibitórias mínimas (CIM) das bactérias para a CHG com e sem o inibidor de bomba de efluxo (CCCP) foram avaliadas nos dois períodos. Os genes de resistência a CHG foram estudados por meio da PCR e a clonalidade dos isolados por eletroforese em campo pulsátil. Resultados: Foi observada redução significativa na incidência de infecção e colonização de VRE na unidade no período pós-intervenção (p: 0,001). Essa taxa permaneceu estável em outras UTIs clínicas do hospital. Contudo as taxas de infecção por Gram negativos multirresistentes aumentou nos últimos anos na unidade. Não ocorreu diminuição na taxa de IRAS na unidade. As CIMs testadas de CHG aumentaram nas amostras de VRE e K. pneumoniae após o período de exposição ao antisséptico, com queda importante da CIM após o uso do CCCP, revelando ser a bomba de efluxo, um importante mecanismo de resistência à CHG. As amostras de A. baumannii e P. aeruginosa não apresentaram aumento da CIM após período de exposição à clorexidina. As bombas de efluxo Ade A, B e C estiveram presentes na maioria dos A. baumannii do grupo controle (66%). A bomba cepA foi encontrada em 67% de todas as K. pneumoniae testadas e em 44,5% das P. aeruginosas do grupo pré intervenção. Observamos uma relação positiva entre a presença da CepA nas amostras de K. pneumoniae e a resposta ao CCCP: de todas as 49 amostras CepA positivas 67,3% obtiveram redução do seu MIC em 4 diluições após adição do CCCP. A avaliação de clonalidade demonstrou padrão policlonal das amostras de VRE, K. pneumoniae e A. baumannii avaliadas. Em relação às amostras de P. aeruginosa foi observado que no período pós-intervenção ocorreu predominância de um clone com > 80% semelhança em 10 das 22 amostras avaliadas pelo dendrograma. Conclusões: O banho de clorexidina teve impacto na redução da incidência de infecção e colonização por VRE na unidade de TCTH, e não teve o mesmo impacto nas bactérias gram-negativas. Os mecanismos moleculares de resistência à clorexidina estão intimamente ligados à presença de bomba de efluxo, sendo provavelmente o principal mecanismo de resistência e tolerância das bactérias ao antisséptico / Background and objectives: Daily skin cleansing with 2% chlorhexidine gluconate (CHG) in patients in intensive care unit is associated with reduction in incidence of multiresistant microorganisms (MR). Data in Hematological Steam Cell Transplant (HSCT), however, is scarce, and studies addressing the impact of this intervention in this population are needed. The aim of this study was to evaluate the effectiveness of daily bathing with CHG in reducing infection and colonization by MR (vancomycin resistance Enterococcus -VRE, P. aeruginosa, A. baumannii and K. pneumoniae) in HSCT patients and also evaluated the antiseptic susceptibility comparing pre and post intervention period. Methods: We perform a 9 year pre and post interventional study. In August 2009, was implemented daily bathing with CHG, replacing regular soap in all patients in a 12 beds HSCT ward, located in a tertiary reference hospital in Sao Paulo/Brazil. The goal of the intervention was decreasing MR prevalence in the unit. Therefore we evaluated the incidence-density (ID=cases/1000 patient days) of MR colonization and infection in periods of 4.5 years before and 4.5 years after intervention. Minimum inhibitory concentration (MIC) values were tested for CHG using Muller-Hinton agar dilution in MR strains isolated pre and post intervention period. The behavior of the strains after introduction of an efflux pump inhibitor (CCCP) was also assessed to study the importance of this resistance mechanism in relation to CHG. Statistical analyzes were performed using time-series analyses in ARIMA model, and SPSS program was used. P < 0.05 was considered statistically significant. Results: A significant reduction in infection and colonization VRE incidence was observed in post-intervention period (p 0.001). The opposite occurred with gran-negative infection and colonization rates, which had increased in recent years at the unit (p < 0.001). Rates of blood stream infection (BSI) remained stable in both periods. The VRE and K. pneumoniae strains showed two fold MIC 50 increase in in the post exposure period. However the strains of P. aeruginosa and A. baumannii had no MIC 50 increase after antiseptic exposure period. All MIC 50 strains was significant reduced after using the efflux pump inhibitor (CCCP) Conclusions: The CHG bath showed to be effective in reducing VRE infection and colonization in HSCT unit, and corroborating the literature the same impact was not taken in gram-negative bacteria. The unit microbiota has been impacted by the CHG massive use, however the increase MIC seemed not influence the efficacy of intervention in VRE cases. Molecular mechanisms of resistance to chlorhexidine are closely linked to the presence of efflux pump

Page generated in 0.0854 seconds