• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 119
  • 26
  • 6
  • Tagged with
  • 156
  • 49
  • 40
  • 30
  • 28
  • 28
  • 25
  • 24
  • 23
  • 23
  • 21
  • 18
  • 18
  • 17
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Etanchéité des matériaux pour obturations radiculaires et coronaires en odontologie : approche physico-chimique / Watertightness of endodontic and coronal restorative materials : physicochemical approach

Jacquot, Bruno 19 December 2011 (has links)
Ce travail de thèse est scindé en 4 parties. La première partie est une approche originale en odontologie par modélisation de la pénétration de colorants à l'interface des matériaux pour obturation radiculaire. Les deux situations extrêmes ont été envisagées. Lorsque l'interface est remplie uniquement par de l'air à pression atmosphérique, la pénétration s'effectue par capillarité. Lorsque l'interface est remplie d'eau, la pénétration s'effectue par diffusion. Les différentes équations physiques qui régissent ces phénomènes ont été déterminées. Les différents paramètres d'influence ont été quantifiés. La seconde partie et la troisième partie est une revue de littérature critique concernant l'influence de l'humidité relative et de la température du milieu buccal sur l'adhérence et l'étanchéité des matériaux adhésifs pour obturation coronaire. Une corrélation a été recherchée entre les études de laboratoire et les études cliniques. La quatrième partie est la mise au point d'un modèle permettant d'évaluer la pénétration de l'eau liquide et de l'eau gazeuse à la surface des matériaux adhésifs utilisés en odontologie. L'analyse de surface est réalisée par Spectroscopie Raman et le degré de conversion de ces résines méthacryliques est quantifié. La couche d'inhibition par l'oxygène de l'air est caractérisée en épaisseur et en degré de conversion. Une comparaison est effectuée entre les composites d'obturation, les composites flow et différents systèmes adhésifs amélo-dentinaires. / This thesis is divided into 4 partsThe first part is an original approach in dentistry by modeling the penetration of dyes at the interface of root filling materials. The two extreme situations were considered. When the interface is filled only with air at atmospheric pressure, the penetration is by capillary action. When the interface is filled with water, the penetration is by diffusion. The different physical equations governing these phenomena have been determined. The influence of the various parameters were quantified. The second part and third part are a review of critical literature on the influence of relative humidity and temperature of the oral environment on adhesion and sealing material for sealing coronary adhesives. A correlation was sought between laboratory studies and clinical trials.The fourth part is the development of a model to assess the penetration of liquid water and water vapor on the surface of the adhesive materials used in dentistry. Surface analysis is carried out by Raman spectroscopy and the degree of conversion of the methacrylate resins is quantified. Layer inhibition by oxygen is characterized by thickness and degree of conversion. A comparison is made between the composite filling, the composite flow and various adhesive systems enamel-dentin.
82

Différence d'échelle spatiale entre les mesures satellitaires et in situ d'humidité du sol : analyse par des approches spatio-temporelles / Analysis of the spatial scale mismatch between satellite and ground measurements of soil moisture using spatio-temporal approaches

Molero Rodenas, Beatriz Molero 18 December 2017 (has links)
L'humidité du sol est une variable climatique essentielle dont le suivi à l'échelle globale est possible grâce à des instruments micro-ondes à bord des satellites. La précision de ces estimations est validée par comparaison directe aux mesures au sol. Tandis que les estimations satellitaires ont des résolutions allant de 30 à 100 km, les capteurs in situ sont généralement représentatifs d'une zone de quelques centimètres (résolution ponctuelle). Cette différence entre l'échelle spatiale des estimations satellitaires et in situ impacte le processus de validation et les statistiques obtenues à un niveau qui n'est pas connu actuellement. Cette thèse vise à améliorer la connaissance de l'impact du changement d'échelle spatiale, ainsi qu'à fournir des méthodes d'évaluation de celle-ci applicables à toute zone de validation. Pour ce faire, la relation entre les échelles spatiales et temporelles a été étudiée. Des séries modélisées et mesurées sur des régions différentes du globe ont été décomposées en échelles de temps allant de 0,5 et 128 jours, en utilisant des transformées en ondelettes. La représentativité spatiale des mesures à résolution ponctuelle a ensuite été évaluée, par échelle de temps, avec 4 approches différentes : l'analyse de la stabilité temporelle, la triple colocation, le pourcentage de zones corrélées (CArea) et une nouvelle approche utilisant des corrélations basées sur des ondelettes (WCor). De plus, l'incertitude d'échantillonnage a été évaluée séparément avec des approches bootstrap et des simulations de Monte Carlo de séries à résolution ponctuelle. À l'issue de ces expériences, il y a été constaté que la moyenne des valeurs de représentativité spatiale obtenues tend à augmenter avec l'échelle de temps, mais aussi leur dispersion. Cela implique que certaines stations ont de vastes zones de représentativité à des échelles saisonnières, tandis que d'autres ne l'ont pas. Aux échelles sous-hebdomadaires, toutes les stations présentaient de très petites zones de représentativité. Enfin, l'impact de l'incertitude d'échantillonnage s'est avéré assez important dans les métriques de validation satellitaire. / Soil moisture is an essential climate variable that is globally monitored with the help of satellite borne microwave instruments. The accuracy of satellite soil moisture estimations is assessed by direct comparison to in situ measurements. While satellite estimates have a resolution ranging between 30 and 100 km, in situ sensors typically measure over an area of a few centimetres (point resolution). This spatial scale mismatch between satellite and in situ soil moisture estimates impairs the validation process and the respective summary statistics to an extent that is not currently known. This thesis aims at improving the knowledge of the spatial scale mismatch, as well as providing methods for its assessment applicable to any validation area. To this end, the connection between the SM spatial and time scales was investigated. Modelled and measured soil moisture series at different regions of the globe were decomposed into time scales ranging from 0.5 to 128 days, using wavelet transforms. The spatial representativeness of the point measurements was then assessed, on a per time scale basis, with 4 different approaches: temporal stability analysis, triple collocation, the percentage of correlated areas (CArea) and a new approach that uses wavelet- based correlations (WCor). Moreover, one of the components of the mismatch, the sampling uncertainty, has been assessed separately with bootstrap and Monte Carlo simulations of point-support series. It was found that the average of the spatial representativeness values tends to increase with the time scales but so does their dispersion. This implies that some stations had large representativeness areas at seasonal scales, while others do not. At sub-weekly scales, all stations exhibited very small representativeness areas. Finally, the sampling uncertainty has been observed to have a considerable impact on satellite validation statistics.
83

Détermination d'un modèle en trois dimensions de la réfractivité troposphérique à partir d'un réseau de récepteurs GPS au sol

Macias-Valadez, Daniel 12 April 2018 (has links)
Le délai troposphérique subi par les signaux GPS entre les satellites et le récepteur affecte la précision du positionnement mais contient aussi de l'information utile sur l'état de la troposphère. Le délai troposphérique consiste en une composante hydrostatique et une composante humide qu'il est possible de séparer. Avec un réseau permanent de récepteurs GPS, où la position des sites est connue avec précision, et en utilisant l'information sur les délais en pente humides (SWD, de l'anglais Slant Wet Delays) estimés entre chaque station et tous les satellites visibles, il est possible de dresser un modèle en trois dimensions de la réfractivité humide au-dessus du réseau. La présente recherche porte sur l'utilisation de fonctions en séries de Taylor en trois dimensions afin de modéliser la réfractivité humide. Un réseau permanent de 43 stations en Suisse a été utilisé afin d'estimer en post-traitement les SWD et de les utiliser comme données d'entrée au modèle de la réfractivité humide proposé. Cette modélisation permet de calculer les délais troposphériques zénithaux humides en tout point à l'intérieur du réseau pour que d'autres récepteurs GPS qui ne font pas partie du réseau puissent corriger l'effet troposphérique. Une comparaison des résultats a été effectuée par rapport à l'utilisation traditionnelle d'une atmosphère standard et un facteur d'amélioration moyen de 30\% a été atteint. D'autre part, des données météorologiques recueillies dans des stations indépendantes du réseau GPS ont été utilisées afin de valider les valeurs de réfractivité humides calculées par le modèle. La concordance entre ces valeurs et celles de validation est à 2 unités près en moyenne. / Le délai troposphérique subi par les signaux GPS entre les satellites et le récepteur affecte la précision du positionnement mais contient aussi de l'information utile sur l'état de la troposphère. Le délai troposphérique consiste en une composante hydrostatique et une composante humide qu'il est possible de séparer. Avec un réseau permanent de récepteurs GPS, où la position des sites est connue avec précision, et en utilisant l'information sur les délais en pente humides (SWD, de l'anglais Slant Wet Delays) estimés entre chaque station et tous les satellites visibles, il est possible de dresser un modèle en trois dimensions de la réfractivité humide au-dessus du réseau. La présente recherche porte sur l'utilisation de fonctions en séries de Taylor en trois dimensions afin de modéliser la réfractivité humide. Un réseau permanent de 43 stations en Suisse a été utilisé afin d'estimer en post-traitement les SWD et de les utiliser comme données d'entrée au modèle de la réfractivité humide proposé. Cette modélisation permet de calculer les délais troposphériques zénithaux humides en tout point à l'intérieur du réseau pour que d'autres récepteurs GPS qui ne font pas partie du réseau puissent corriger l'effet troposphérique. Une comparaison des résultats a été effectuée par rapport à l'utilisation traditionnelle d'une atmosphère standard et un facteur d'amélioration moyen de 30\% a été atteint. D'autre part, des données météorologiques recueillies dans des stations indépendantes du réseau GPS ont été utilisées afin de valider les valeurs de réfractivité humides calculées par le modèle. La concordance entre ces valeurs et celles de validation est à 2 unités près en moyenne.
84

Influence de la température et de la teneur en humidité sur les propriétés mécaniques du bois associées au procédé de fragmentation par équarrisseuse-fragmenteuse

Passarini, Leandro 17 April 2018 (has links)
Cette étude a évalué l’influence de la température et de la teneur en humidité du bois sur son comportement mécanique lors du procédé d’obtention des copeaux papetiers. Les propriétés mécaniques qui furent étudiées sont le cisaillement parallèle au fil, le fendillement et la flexion statique. Des échantillons jumelés du duramen et de l’aubier ont été pris des billes d’épinette noire et de sapin baumier pour chaque propriété mécanique. Les essais mécaniques ont été conduits à des températures variant entre -30ʻC et 20ʻC et à des intervalles de 10ʻC. La teneur en humidité des échantillons était largement au-dessus du point de saturation des fibres. La teneur en humidité, la masse volumique basale et la largeur des cernes ont aussi été mesurées pour chaque échantillon. Les résultats montrent que, pour les deux espèces et pour toutes les propriétés mécaniques étudiées, la température a eu un effet significatif sur les propriétés mécaniques uniquement au-dessous de 0ʻC. Dans ce cas, cet effet a été plus évident pour l’aubier que pour le duramen. En général, pour des températures de 0ʻC et plus, la température n’a pas affecté différemment les propriétés mécaniques étudiées, autant pour l’aubier que pour le duramen. Le fendillement a été la propriété mécanique la plus sensible à la variation de la température, suivi par le cisaillement et le MOR et le MOE en flexion. En outre, la teneur en humidité a été l’élément le plus important pour expliquer les propriétés mécaniques au-dessous de 0ʻC. En revanche, pour les températures de 0ʻC et plus, la masse volumique basale fut le facteur principal pour expliquer les propriétés mécaniques. La largeur des cernes de croissance n’a pas constitué un élément significatif pour prédire aucune propriété mécanique. Les résultats de ce travail devraient servir à améliorer la performance des équarrisseuses-fragmenteuses autant en hiver qu’en été.
85

Évaluation de l'efficacité de traitements pour la prévention ou la mitigation de la corrosion de l'acier d'armature dans les éléments en béton armé

Rouleau, Nicolas 19 April 2018 (has links)
Cette étude visait à évaluer l’efficacité de différentes techniques de protection à prolonger la durée de vie des infrastructures en béton susceptibles d’être atteintes de corrosion des armatures. L’objectif principal du projet était de fournir des informations quantitatives sur l’influence de certaines des stratégies les plus couramment utilisées pour protéger les ouvrages contre la pénétration de l’humidité et des ions chlorure ainsi que pour contrôler l’initiation et la propagation de la réaction de corrosion. Ainsi, l’impact de l’utilisation de scellants non coupe-vapeur, de membranes et de produits inhibiteurs de corrosion (migrateur et adjuvant) a été étudié. Les différents traitements ont été testés sur des corps d’épreuve pré-conditionnés de manière à présenter quatre niveaux de contamination et de détérioration : état vierge non corrodé, état contaminé par les ions chlorure mais non corrodé, état de corrosion initiée et état de propagation de la corrosion. Un des objectifs spécifiques de cette étude était d’évaluer l’influence des différents traitements sur l’évolution de facteurs comme la distribution interne de l’humidité relative, la distribution des ions chlorure ainsi que l’activité de corrosion. Pour ce faire, 51 dalles de béton armé ont été fabriquées et exposées à des cycles de mouillage (brouillard salin) et de séchage dans une chambre environnementale. Afin de caractériser l’évolution de l’activité de corrosion propre à chaque condition, un suivi électrochimique des éléments comportant des mesures de potentiel électrochimique et de résistance à la polarisation linéaire a été assuré. À la suite de la période de cyclage dans la chambre de brouillard salin, une autopsie a été pratiqué sur une sélection de corps d’épreuve. Cette opération avait pour but de dégager les barres d’armature de manière à caractériser les zones anodiques. / This study aimed at evaluating the capacity of various protection techniques to extend the service-life of concrete infrastructure affected by reinforcement corrosion. The main objective of this project was to provide quantitative information on the influence of some of the most commonly used strategies in practice to protect reinforced concrete structures against the initiation and propagation of corrosion, respectively non-vapor barrier sealants, waterproofing membranes and corrosion inhibitors products (penetrating and admixture). The various treatments were tested on laboratory-size concrete test slabs pre-conditioned in such a way to exhibit four different stages of contamination and deterioration: virgin, contaminated by chlorides but not corroded, corrosion initiated and corrosion propagating. A specific objective of this study was to evaluate the influence of different treatments on the evolution of various factors such as the internal distribution of relative humidity, the distribution of chlorides and the corrosion activity. Through two successive experimental phases, 51 test slabs were produced and subjected to cycles of wetting (salt spray) and drying in an environmental chamber. In order to monitor the evolution of the corrosion activity for each condition, half-cell potential and linear polarization measurements were carried out on all specimens at regular time intervals. Following the period of cycling in the salt spray chamber, an autopsy was performed on a selection of tested slabs in order to expose the reinforcing steel rebars and allow a characterization of the anodic areas.
86

Variation des propriétés des bois de bouleau jaune et de hêtre à grandes feuilles en fonction de l'humidité d'équilibre à deux températures

Silva Latorre, Zaira Melissa 13 April 2018 (has links)
L'objectif principal de cette étude a été d'établir l'effet de la teneur en humidité d'équilibre sur les propriétés du bois à deux niveaux de température. Deux espèces feuillues tempérées ont été étudiées, soit le bouleau jaune et le hêtre à grandes feuilles. La région près du point de saturation des fibres (PSF) a été particulièrement visée. Deux méthodes de désorption d'humidité aux températures de 25ʻC et 50ʻC ont été appliquées, soit la méthode des solutions salines saturées et celle de la membrane poreuse sous pression. Celles-ci ont été couplées avec des mesures du retrait ainsi qu'à des essais de compression tangentielle. Les résultats ont montré qu'à l'équilibre de sorption, le retrait du bois a commencé avant même d'atteindre le PSF. Alors, ces résultats indiquent qu'une perte de l'eau hygroscopique a lieu en présence d'eau liquide. L'eau liquide qui reste à ce moment serait localisée dans les tissus les moins perméables du bois, soit les rayons ligneux. Une augmentation de la température augmenterait la perméabilité de ces tissus en facilitant la désorption de l'eau restante. Ainsi, la teneur en humidité d'équilibre marquant le début des changements des propriétés du bois diminue avec une augmentation de la température. Cette valeur se rapprocherait ainsi du PSF au fur et à mesure que la température s'élève. De plus, le retrait du bois de hêtre à 50ʻC semble avoir été affecté par un léger collapse localisé dans les zones plus faibles du bois. Enfin, l'hygroscopicité et les propriétés mécaniques du bois ont été plus faibles à 50ʻC qu'à 25ʻC.
87

L'influence de l'eau sur le comportement mécanique des roches argileuses

Freissmuth, Harald 17 December 2002 (has links) (PDF)
Cette thèse a été réalisée en coopération avec ANDRA, l'agence nationale française des déchets radioactives. Son objectif est de donner une meilleure compréhension des propriétés mécaniques des roches argileuses sous l'influence de solutions aqueuses, en admettant qu'elles sont considérées comme des roches susceptibles d'héberger des déchets nucléaires.<br/> L'ardoise peut, selon sa composition, modifier dans un large domaine ses propriétés mécaniques et pétro-physiques à cause des interactions minérales de la glaise liquide. L'ardoise peut être molle ou dure, extensible ou rigide, perméable ou imperméable et ce selon les conditions environnementales auxquelles elle est exposée. Elle peut être très sensible aux changements des conditions environnantes, comme par exemple l'humidité, la contrainte, la température et les gradients du potentiel chimique.<br/> Une des réactions les plus apparentes de l'ardoise est le gonflement et le dégonflement comme résultat de sa saturation et des gradients du potentiel chimique dans le système liquide. Ces variations de volume modifient parfois d'autres propriétés. Selon la consistance et la concentration d'un liquide, l'ardoise peut soit gonfler soit se dégonfler en entrant en contact avec un liquide. Le matériau peut aussi se dissoudre dans le liquide et se désintégrer complètement.<br/> Une description compréhensible des minéraux argileux du site de l'Est a été élaborée. Les micromécanismes physico-chimiques de l'interaction liquide-solide, comme l'adsorption, l'absorption, la capillarité et l'osmose y sont également présentés. Les conséquences possibles de ces mécanismes sur le comportement macro-mécanique, comme le gonflement et le dégonflement, fissuration et autres ont également été analysées.<br/> La technologie des rayons X en microfocus a été introduite et utilisée pour analyser l'ardoise dans des conditions environnementales différentes. L'avantage de cette méthode est son caractère nondéstructif. Dû à la friabilité du matériau, la préparation des lames minces classiques est une méthode inappropriée pour analyser les micro-fissures et la désintégration de l'ardoise.<br/> Les solutions ont été examinées pour observer la réaction en temps réel de l'ardoise dans le site de l'Est quand elle entre en contact avec différentes solutions aqueuses et sous charge uniaxial. La désintégration et la déformation ainsi que les propriétés générales de ce matériau ont été analysées en utilisant la technologie des rayons X μRG en immergeant le matériau dans une solution. On a pu constater que la désintégration, le développement des cracks et la déformation dépendent en partie de la concentration des ions ainsi que des types des ions de la solution.<br/> Lors d'un test cinétique l'ardoise a été exposée à des degrés différents d'humidité relative et à des conditions de pressions uniaxiales. Une enceinte climatique électronique, contrôlée par une ordinateur a été utilisée pour créer des degrés d'humidité différents et on a transféré directement les résultats de la déformation axiale et des paramètres environnementaux. La relation entre l'humidité environnementale, la déformation axiale, la charge axiale et les micro fissures a été analysée. La technologie des rayons X en microfocus a été utilisée pour radiographier des spécimens avant et après les essais. Le matériau a été testé sous une humidité relative de 5% à 99%, pour évaluer l'influence de l'humidité sur le comportement des micro fissures et de la déformation.<br/> Un test cyclique a été développé afin de définir le degré de friabilité dans un secteur entre 35% et 75% d'humidité relative.<br/> Finalement, un test combiné a été réalisé afin de comparer la réaction dans l'eau pure d'un matériau saturé dans un environnement humide avec sa réaction dans l'eau en étant dans son état initial de saturation. Le matériau a été d'abord exposé à une humidité relative de 5% et 99% et ensuite immergé dans l'eau pure. Grâce à ce test on a découvert un phénomène d'hydratation qui pourrait être important pour les procédures des essais normalement appliquées.
88

Analyse de la traficabilité en zone tropicale par imagerie spatiale optique et radar : application au Tchad méridional

Kourdian, Raphaël 14 December 2009 (has links) (PDF)
La connaissance des conditions de déplacement terrestre dans les pays tropicaux est un besoin clé, en particulier en saison des pluies. Ce travail propose une méthodologie de production de diagnostics de traficabilité et de leur restitution cartographique associée, à partir de l'exploitation de données de télédétection spatiale optique et radar, et de données de sources ouvertes. La démarche a été appliquée à plusieurs environnements du Tchad méridional. A l'échelle régionale, une classification dynamique des obstacles, types de sols et végétation est réalisée à partir d'imagerie Landsat et MODIS et de données de relief SRTM. Une estimation spatialisée de la mesure de résistance à la pénétration au cône en est extraite, en fonction de l'humidité et de la densité racinaire, pour chaque classe de sols. Ce résultat est confronté avec les caractéristiques de portance des véhicules pour produire une carte de mobilité. A l'échelle locale, les éléments de l'occupation du sol sont interprétés de l'imagerie très haute résolution Quickbird par une combinaison sélective de classifications SVM et orientée objet. L'humidité du sol est estimée à partir du signal radar du capteur TerraSAR-X. La praticabilité des routes est déterminée en fonction de l'état et du revêtement du réseau routier, et des hauteurs de précipitation quotidiennes. La structure du modèle permet une actualisation rapide et automatisée de la production de diagnostics, par un partitionnement des processus de traitement. Ainsi, elle tire parti du potentiel de l'ensemble des sources disponibles sur la zone d'intérêt (imagerie, données scientifiques, contributions des acteurs de terrain collectées sur le net).
89

Mécanismes et effets de la fonte des accumulations neigeuses sur le fonctionnement hydrologique du Lignon du Forez, Massif Central, France.

Bouron, Gaël 22 November 2013 (has links) (PDF)
Ce travail de thèse propose une méthodologie d'instrumentation reposant sur plusieurs outils hydrologiques, géophysiques et géochimiques afin de quantifier l'apport nival dans les débits du Lignon. Cette instrumentation consiste en un suivi des échanges aux différents compartiments/interfaces hydrologiques que forment l'atmosphère, la neige, le sol et les cours d'eau au cours des saisons. La neige, et surtout l'équivalent en eau liquide qu'elle représente, est fondamentale pour la compréhension du fonctionnement des sources du Lignon, situées à l'aval direct d'une congère de grand volume. Ce volume d'eau est stocké durant la saison froide pour être restitué lors de la fonte printanière. Cette restitution est loin d'être homogène dans le Haut Lignon, en raison de la forte variabilité spatio-temporelle des paramètres qui la pilotent.L'infiltration de l'eau alors produite est une étape clef dans le comportement hydrologique du Lignon au printemps. La structure du sol à proximité des sources explique également la forte dépendance des sources du Lignon par rapport aux précipitations neigeuses. Cette dépendance est particulièrement visible lors de la fonte de la neige, qui modifie à très court terme les débits aux sources. Cette relation neige-pluie-débit met en évidence une alimentation superficielle pluvio-neigeuse prépondérante par rapport aux débits issus d'eau plus profonde, mais variable au cours de l'année.La méthode d'instrumentation employée, adaptée à l'hydrologie locale employée, permet de corroborer les résultats obtenus avec une précision appréciable, tout en ouvrant de nouvelles perspectives d'application à d'autres bassins versants d'altitude.
90

Caractérisation des maladies respiratoires en lien avec les problématiques d’humidité excessive ou de moisissures dans les logements des étudiants universitaires

Lanthier-Veilleux, Mathieu January 2016 (has links)
Résumé : PROBLÉMATIQUE: L’exposition résidentielle à l’humidité excessive ou aux moisissures est maintenant reconnue comme un facteur important influençant la santé respiratoire. Cette problématique a été peu étudiée chez les étudiants universitaires, bien que vulnérables par leur faible revenu et leur statut de locataire. OBJECTIFS: Cette maîtrise vise à décrire la prévalence (a) de l’exposition résidentielle à l’humidité excessive ou aux moisissures et (b) des maladies respiratoires chez les étudiants universitaires, ainsi qu’à (c) examiner l’association entre l’exposition résidentielle à l’humidité excessive ou aux moisissures et ces maladies. MÉTHODES: En 2014, une enquête électronique a été réalisée auprès de 2097 étudiants enregistrés à l’Université de Sherbrooke (Québec, Canada). Lorsque possible, des questions et des scores validés ont été utilisés pour estimer les prévalences des maladies respiratoires (rhinite allergique, asthme et infections respiratoires), de l’exposition résidentielle à l’humidité excessive ou aux moisissures et des covariables (ex. : revenu annuel familial, statut tabagique, atopie familiale, caractéristiques de l’étudiant). Les associations entre cette exposition et ces maladies ont d’abord été examinées par des tests de chi-carré en utilisant un seuil alpha de 0,05. Des régressions logistiques multivariées ont ensuite été utilisées pour déterminer les associations brutes et ajustée entre cette exposition et les maladies respiratoires. Les analyses descriptives ont été pondérées pour le sexe, l’âge et le campus d’étude. RÉSULTATS: L’exposition à l’humidité excessive ou aux moisissures était fréquente parmi les participants (36,0%; Intervalle de confiance (IC)95% : 33,9-38,1). Ceux-ci ont également été nombreux à rapporter une rhinite allergique (23,9%; IC95% :22,0-25,8), de l’asthme (32,6%; IC95% : 30,5-34,7) et des infections respiratoires (19,4%; IC95% :17,7-21,2) au cours de la dernière année. Après ajustement, les associations demeuraient significatives entre l’exposition à l’humidité excessive ou aux moisissures et la rhinite allergique (Rapport de cote (RC) : 1,30; IC95% : 1.05-1.60), l’asthme RC : 1,75; IC95% : 1,42-2,16), mais pas les infections respiratoires (RC : 1,07; IC95% : 0,85-1.35). CONCLUSIONS: La prévalence élevée de l’exposition résidentielle des étudiants universitaires à l’humidité excessive ou aux moisissures, de même que son association avec l’asthme et la rhinite allergique, mettent en lumière sa contribution potentielle à la forte prévalence des maladies respiratoires ayant une composante allergique dans cette population. Cette étude fournit un nouveau levier pour les organisations de santé publique et leurs partenaires afin d’adapter les stratégies préventives ciblant les logements insalubres, particulièrement chez les populations vulnérables. / Abstract : PROBLEMATIC: Indoor residential dampness and mold is now recognised as a major respiratory health determinant. University students are vulnerable to such exposure by their low income and high mobility, but few studies have assessed their exposure. OBJECTIVES: This project aims to describe prevalence of (a) residential dampness or mold exposure and (b) respiratory diseases in University students as well as to (c) examine the independent contribution of residential excessive dampness and mold to these diseases. METHODS: In 2014, an online survey was conducted among 2097 students registered at the University of Sherbrooke (Quebec, Canada). Validated questions, and scores when possible, were used to assess respiratory diseases (allergic rhinitis, asthma-like symptoms, respiratory infections), residential excessive dampness and mold, and covariates (e.g. family annual income, smoking status, parental atopy, student characteristics). Associations between exposure and diseases were first evaluated using bivariate analyses (khi-square tests) with an alpha value of 0.05. Using logistic regressions, the crude and adjusted relationships between residential excessive dampness or mold and respiratory diseases were examined. Results were weighted for sex, age and campus affiliation. RESULTS: Residential dampness or mold exposure was frequent (36.0%; 95%Confidence Interval (CI) : 33.9-38.1). Respondents also reported high prevalence of allergic rhinitis (32.6%; 95%CI : 30.5-34.7), asthma-like symptoms (23.9%; 95%CI : 22.0-25.8) and respiratory infections (19.4%; 95%CI : 17.7-21.2). After adjustment, associations with residential excessive dampness or mold were significant for allergic rhinitis (Odd Ratio(OR) : 1.30; 95%CI : 1.05-1.60) and asthma-like symptoms (OR : 1.75; 95%CI : 1.42-2.16), but not for respiratory infections (OR : 1.07; 95%CI : 0.85-1.35). CONCLUSIONS: High frequency of residential excessive dampness and mold, as well as its associations with asthma and allergic rhinitis highlight this exposure’s potential contribution to high atopy prevalence among university students. These results emphasize the importance for public health organizations to tackle poor housing, especially for vulnerable populations.

Page generated in 0.0303 seconds