• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 340
  • 11
  • 11
  • 11
  • 11
  • 8
  • 4
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 348
  • 125
  • 118
  • 93
  • 89
  • 47
  • 43
  • 42
  • 41
  • 40
  • 39
  • 38
  • 37
  • 33
  • 33
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
251

RELAÇÃO ENTRE ATRIBUTOS DO SOLO E OCORRÊNCIA DA AROEIRA DO SERTÃO (Myracrodruon urundeuva Freire Allemão) NA RPPN FAZENDA BULCÃO, MÉDIO RIO DOCE, MG / Relationship between attributes of the soil and occurrence of the aroeira do sertão (Myracrodruon urundeuva Freire Allemão) in the RPPN Bulcão Farm, Doce River medium, MG

Jaeder Lopes Vieira 25 July 2008 (has links)
Extensas áreas da região do vale do rio Doce estão sendo tomadas pela aroeira do sertão, Myracrodruon urundeuva Freire Allemão, principalmente em áreas já ocupadas por pastagens. A RPPN Fazenda Bulcão localizada em Aimorés (vale do rio Doce), Minas Gerais, apresenta parte significativa de suas terras ocupadas por esta espécie. O manejo da aroeira do sertão na Fazenda Bulcão, dentro de áreas de reflorestamento, tem se tornado de fundamental importância, visando aumentar a diversidade das espécies instaladas, visto que a aroeira apresenta alta competitividade. Portanto, entender os mecanismos biológicos e sua relação com os aspectos físicos e químicos do ambiente relacionados com a dispersão e desenvolvimento dessa espécie contribuirá para os trabalhos conduzidos pela RPPN no reflorestamento da área, divulgando com isso os conhecimentos para toda região. Para isso, realizou-se um levantamento dos solos com ocorrência ou não da aroeira, da geomorfologia, caracterização química e física dos solos e a velocidade de infiltração básica dos solos, relacionando todos os atributos com a densidade de plantas de aroeira. Os resultados indicaram que a aroeira do sertão Myracrodruon urundeuva Freire Allemão ocorre preferencialmente em solos de maior declividade, com maiores teores de cálcio e magnésio, com menores acidez e alumínio trocável e menores valores de velocidade de infiltração básica de água. A aroeira do sertão apresenta uma prevalência em ocupar áreas pertencentes às classes de declividade forte-ondulado e montanhoso. As menores velocidades de infiltração de água no solo com a presença da aroeira demonstram uma resistência desta espécie a déficit hídrico, sendo uma espécie caducifólia de importância econômica. / Extensive areas of the Doce River Valley region are being taken by the aroeira do sertão, Myracrodruon urundeuva Freire Allemão, mainly in areas already occupied by pastures. The RPPN Bulcão Farm located in Aimorés (Doce River Valley), Minas Gerais, presents a significant part of its land occupied by these species. The handling of the aroeira do sertão in the Bulcão Farm, in reforestation areas, has became of fundamental importance, seeking to increase the diversity of the installed species, because the aroeira presents high competitiveness. Therefore, to understand the biological mechanisms and their relationship with the physical and chemical aspects of the environment related with the dispersion and development of these species will contribute to the work led by the RPPN in the reforestation of the area, disclosing with that the knowledge for every area. For that, a survey of the soils with the occurrence or not of the aroeira was carried out, of the geomorphology, chemical and physical characterization of the soils and the speed of basic infiltration of the soils, relating all the attributes with the density of aroeira plants. The results indicated that the aroeira do sertão Myracrodruon urundeuva Freire Allemão happens preferentially in soils of larger steepness, with larger tenors of calcium and magnesium, with smaller acidity and exchangeable aluminum and smaller values of speed of basic infiltration of water. The aroeira do sertão presents prevalence in occupying areas belonging to the classes of steepness strong-waved and mountainous. The smallest speeds of infiltration of water in the soil with the presence of the aroeira demonstrate a resistance of this species to hydro deficit, being a caducifólia specie of economical importance.
252

Análise paramétrica e dimensionamento de poços de infiltração para fins de drenagem urbana / Parametric analysis and design of infiltration wells for urban drainage

Peixoto, Vinicius Carvalho 15 April 2011 (has links)
A combinação entre a falta de planejamento urbano e o crescimento indiscriminado de áreas impermeáveis é responsável pela ocorrência de enchentes em centros urbanos. O emprego de dispositivos de controle do escoamento superficial na fonte geradora, como poços e trincheiras de infiltração, pavimentos permeáveis e jardins de infiltração (rain gardens), é uma alternativa que permite restabelecer o processo de infiltração em áreas urbanas densamente impermeabilizadas. Neste contexto, efetuou-se uma análise paramétrica acerca da influência das funções condutividade hidráulica e das curvas de retenção dos solos no processo de infiltração de água em poços cilíndricos instalados em solos inicialmente não saturados. Para a realização das análises paramétricas, foi empregado o programa SEEP/W do pacote GeoStudio 2004, que utiliza a técnica dos elementos finitos na solução numérica da equação de Richards que rege o fluxo de água em meio não saturado. As análises paramétricas mostraram que o coeficiente de condutividade hidráulica saturada do solo é o parâmetro que apresenta maior relevância no processo de infiltração de água em poços. Com isto, desenvolveu-se uma técnica de dimensionamento de poços de infiltração que permite determinar o volume de água infiltrada em um dado poço em função do tempo de precipitação, do coeficiente de condutividade hidráulica saturada do solo e da área total do poço. Por fim, comparou-se o volume estimado de água infiltrada obtido através da técnica de dimensionamento com o volume medido em um ensaio de infiltração realizado por Lima (2009) em uma trincheira de pequenas dimensões e pôde-se constatar que o a técnica de dimensionamento desenvolvida é consistente com o ensaio de infiltração realizado em campo. / The chief consequence of unplanned urban sprawl is the turning to impervious large tracts of land. Impervious developed areas are prone to floods during heavy rains. Flooding may be mitigated by installation of devices that can control runoff at the source. Examples of control devices are infiltration wells, infiltration trenches, permeable pavement, and rain gardens. By facilitating infiltration, such devices serve to return to the soil below the waterproofed area the waters that would otherwise be lost as runoff, which overloads urban drainage. A study of infiltration wells was conducted through parametric analyses of hydraulic conductivity function and soil-water characteristics curve of unsaturated soils in the process of infiltration. This research used the computer program SEEP/W by GeoStudio 2004 to carry out the parametric analysis. SEEP/W uses the finite element method for the numerical solution of Richards equation, which describes water flow in the unsaturated zone. The parametric analysis showed that the saturated hydraulics conductivity of the soil is the parameter that has greater relevance in the process of infiltration of water into the soil surrounding the wells. Based on the results obtained, a technical procedure was developed to assist the consulting professional to size the infiltration wells. The variables employed in the proposed design procedure consist of time of precipitation, saturated hydraulic conductivity, and total surface area of well. Further, it was compared the estimated volume of infiltrated water obtained through this procedure to the measured volume obtained by Lima (2009) in a small trench. It was observed that the scaling procedure proposed by this work yields results consistent with infiltration field experiments such as that conducted by Lima (2009).
253

AVALIAÇÃO DA INFLUÊNCIA DA CICLAGEM TÉRMICA E MECÂNICA NA EFETIVIDADE DA INTERFACE ADESIVA

Sánchez-ayala, Alfonso 31 January 2008 (has links)
Made available in DSpace on 2017-07-24T19:21:56Z (GMT). No. of bitstreams: 1 Alfonso Sanchez-Ayala.pdf: 4109673 bytes, checksum: f08284c2e1c48354c9d9e417e1b9484e (MD5) Previous issue date: 2008-01-31 / The aim of this study was to evaluate in vitro the adhesive effectiveness in class V cavities using four different adhesive systems, being submit to thermocycling and occlusal load cycling. The cavities had a dimension of 3x2x1.8 mm3 and were made on amelo-cement junction on buccal and lingual of 80 human premolars (n=160). The used adhesive systems were Adper Single Bond 2, AdheSE, Adper Prompt LPop and One Coat 7.0. The used composite was Synergy® D6. The adhesive and photopolymerization (600 mW/cm2) proceedings were made conventionally and following the manufacturer recommendations. The specimens were divided in 4 groups (n=40) according to adhesive system used. Each group was divided in 4 subgroups (n=10) according to applycated stress (thermocycling, occlusal load cycling and thermocycling+occlusal load cycling). Each subgroup included 1 control group without stressing. The thermocycling was made using 500 cycles, with 5-55 C, dwell time of 15 seg and transfer time of 5 seg. The occlusal load cycling was made applying a force of 40-70 N during 50000 cycles with 2 Hz of frequency. Later, the specimens were impermeabilited and immersed in tracer agent of 50 % silver nitrate solution by 2 hours. Finally, the specimens were prepared for adhesive effectiveness evaluation through optic microscopy 40X (marginal microleakage occurrence) and scanning electronic microscopy 1000X (gaps formation). The tracer agent microleakage was measured qualitative (score) and quantitatively . The gap width was measured on 3 points of center of axial wall. The Kruskal-Wallis and post-hoc de Dunn, and ANOVA two-way and post-hoc Bonferroni tests were used on statistic analysis. Despite of few differences found in used adhesive system performance, the tendency could be observed to the increase of the marginal microleakage in the submitted groups specifically to thermocycling. On the other hand, the axial gaps formation presented progressively higher width in the submitted groups to thermocycling, occlusal load cycling and thermocycling+occlusal load cycling. It was concluded that the used adhesive system presented similar adhesive effectiveness when were submitted to thermal and mechanical stress. / A proposição deste estudo foi avaliar in vitro a efetividade adesiva em cavidades de classe V utilizando quatro diferentes sistemas adesivos, sendo submetidas a termociclagem e carga cíclica oclusal. As cavidades tiveram uma dimensão de 3x2x1.8 mm3 e foram realizadas na união amelo-cementária em vestibular e lingual de 80 pré-molares humanos (n=160). Os sistemas adesivos empregados foram Adper Single Bond 2, AdheSE, Adper Prompt L-Pop e One Coat 7.0. A resina composta utilizada foi Synergy D6. Os procedimentos de adesão e fotopolomerização (600 mW/cm2) foram realizados convencionalmente e seguindo as recomendações do fabricante. Os espécimes foram divididos em 4 grupos (n=40) segundo o tipo sistema adesivo utilizado. Cada grupo foi dividido em 4 subgrupos (n=10) segundo o tipo de estresse aplicado (termociclagem, carga cíclica oclusal e termociclagem+carga cíclica oclusal). Cada subgrupo incluiu 1 grupo controle sem estresse. A termociclagem foi realizada utilizando 500 ciclos a 5-55 C, 15 seg de tempo de permanência em cada temperatura e 5 seg de tempo de transferência. A carga cíclica oclusal foi realizada aplicando uma força de 40-70 N durante 50000 ciclos com freqüência de 2 Hz. Posteriormente, os espécimes foram impermeabilizados e imersos em agente traçador de solução a 50 de nitrato de prata por 2 horas. Finalmente, os espécimes foram preparados para a avaliação da efetividade adesiva por meio de microscopia óptica 40X (ocorrência de microinfiltração marginal) e microscopia eletrônica de varredura 1000x (formação de fendas). A microinfiltração do agente traçador foi mensurada qualitativa (escore) e quantitativamente . A largura das fendas foi medida (μm) em 3 pontos do centro da parede axial. Os testes de Kruskal-Wallis e post-hoc de Dunn, e ANOVA two-way e post-hoc Bonferroni foram utilizados na análise estatística. Apesar das poucas diferenças significativas encontradas no desempenho dos sistemas adesivos utilizados, pôde-se observar a tendência ao aumento da microinfiltração marginal nos grupos submetidos especificamente a termociclagem. Por outro lado, a formação de fendas axiais apresentaram progressivamente maior largura nos grupos submetidos a termociclagem, carga cíclica e termociclagem+carga cíclica. Concluise que os sistemas adesivos avaliados apresentaram efetividade adesiva similar quando foram submetidos a estresse térmico e mecânico.
254

Estudo geológico-geotécnico dos processos erosivos e proposta de macrodrenagem: Voçoroca do Córrego do Cravo (Nazareno-MG) / Geological and geotechnical study of erosive processes and proposition of a macro-drainage system: Córrego do Cravo Gully (Nazareno-MG, Brazil)

Sampaio, Ligia de Freitas 19 May 2014 (has links)
A dinâmica dos sistemas naturais se constrói na integração de todos os elementos pertencentes ao ambiente. Caso o conhecimento do meio físico e da influência das atividades antrópicas nesta dinâmica não sejam considerados em conjunto com o uso e ocupação, problemas ambientais de difícil recuperação, como as voçorocas, podem ser gerados, prejudicando a própria manutenção e expansão das atividades humanas. Neste sentido, o objetivo desta pesquisa foi avaliar de forma integrada os condicionantes geológicos e geotécnicos e as propriedades que interferem na drenagem da água superficial e subsuperficial em uma voçoroca do município de Nazareno, no estado de Minas Gerais (voçoroca do Córrego do Cravo). Diante disso, foram elaborados mapas com a utilização de SIG para levantamento e análise das características da bacia do Córrego do Cravo e da bacia de contribuição da voçoroca. Ensaios em laboratório (permeabilidade, erodibilidade, parâmetros físico-químicos, matéria orgânica, MCT e MEV/EDS) foram realizados para caracterização geológica e geotécnica, assim como o tratamento de dados pluviométricos e o programa ABC 6, para estudo do comportamento e da vazão das chuvas. Por fim, para avaliação das propostas de macrodrenagem na bacia de contribuição da voçoroca do Córrego do Cravo, utilizou-se o programa Canal. Os resultados apontaram que, nesta região, as elevadas declividades e susceptibilidade do solo saprolítico (Cambissolo) são os principais condicionantes do ambiente, sendo a intensidade das chuvas, as direções do fluxo superficial, sua concentração (originada pela retirada da cobertura vegetal e manejo inadequado do solo tanto pelas atividades agropecuárias como pela implantação de obras de infraestrutura, como estradas, por exemplo), e a exposição do nível d\'água subterrâneo no interior da voçoroca, os principais fatores que proporcionam o desenvolvimento e retorno dos processos erosivos. Dessa forma, a redução do volume e da energia do escoamento superficial em direção ao solo saprolítico, concomitante ao recolhimento e disciplinamento da água subsuperficial no interior da voçoroca, são consideradas imprescindíveis à estabilização dos processos erosivos. As propostas de macrodrenagem, de maneira geral, poderão ser aplicadas, não somente na voçoroca do Córrego do Cravo, mas também em outras voçorocas de Nazareno com propriedades geológicas-geotécnicas similares. / The dynamics of natural systems are based on the integration of all environmental elements. If the knowledge of physical conditions and of the influence of anthropogenic activities are not considered jointly with land use difficult environmental problems, as gullies, are generated and may cause damages both on maintenance and on expansion of human activities. Thus, this research aims to evaluate the geological and geotechnical constraints and properties which interfere in the superficial and subsuperficial drainage systems of a gully in the Nazareno municipality, at Minas Gerais state, Brazil (Córrego do Cravo gully). Therefore, maps to survey data from the Córrego do Cravo basin and the gully contribution area were made, using GIS tools. In addition, laboratory tests (permeability, erodibility, physical-chemical parameters, organic matter, MCT and SEM/EDS) were conducted for a geological and geotechnical characterization, as well as a study of the precipitation data was done and the software ABC 6 was used to evaluate rainfall and flow. Finally, for the macro drainage system assessment the software Canal was used. The results showed that the steep slopes and the saprolite soil susceptibility (Cambisol) are the main environmental constraints, and the rainfall intensity, the flow directions and its concentration (that is generated by the removal of vegetation and inadequate land use, both urban and agricultural), and the exposure of the water table level in the gully are the main factors that developed and brought the erosive processes back. Hence, both flow volume and energy towards the saprolite soil, in addition with subsuperficial water collection and its discipline inside the gully, are considered indispensable to stabilize of the erosive processes. The macro drainage system proposition can be applied in other gullie areas with similar geological and geotechnical properties.
255

Avaliação da influência do laser de Er:YAG no selamento de cavidades de cárie radicular induzidas in vitro e restauradas com cimentos de ionômero de vidro / Evaluation of the influence of the Er:YAG laser on the sealing of in vitro induced root caries cavities restored with glass ionomer cements

Mello, Andrea Malluf Dabul de 10 May 2005 (has links)
Os insucessos ligados à restauração das cáries radiculares, como a micro-infiltração e cáries secundárias, são muitas vezes causados por fatores como difícil acesso à lesão e ao tipo de substrato. Isto leva à busca de novos materiais restauradores e técnicas de preparo cavitário que possam minimizar ou até mesmo acabar com estes insucessos. Assim, a proposição deste estudo foi induzir cárie radicular in vitro e então verificar a capacidade de selamento marginal de dois tipos de cimento de ionômero de vidro (Ketac Fill Plus e Vitremer), a essas cavidades de cárie preparadas com o laser de Er:YAG. Foram utilizados 45 dentes humanos, entre molares e pré-molares, os quais foram submetidos a um desafio cariogênico, in vitro, para levar à formação de lesões cariosas nas superfícies radiculares, através de um modelo bacteriano. A remoção da cárie foi realizada com três métodos de preparo diferentes, sendo dois grupos com o laser de Er:YAG, um com energia de preparo (250 mJ, 4 Hz, 80.6 J/cm2) e outro com a associação desta energia com uma energia de condicionamento (60 mJ e 2 Hz, 19,2 J/cm2) e um terceiro grupo com remoção convencional utilizando instrumento cortante rotatório (controle). Três dentes de cada grupo foram separados e preparados para microscopia eletrônica de varredura para observações morfológicas do substrato irradiado com o laser e preparado convencionalmente. Os 36 dentes restantes foram divididos em seis grupos (seis dentes para cada grupo de preparo), de acordo com o material restaurador utilizado. Após o procedimento restaurador os dentes foram submetidos à termociclagem (1.000 ciclos), e preparados para o teste de micro-infiltração. O 8 selamento, avaliado pelo grau de infiltração do azul de metileno a 2%, foi mensurado e transformado em escores. Os dados em triplicata foram comparados estatisticamente pelo método de Kruskall-Wallis omplementado pelo teste de Dunn. Os melhores escores foram dos grupos que utilizaram a associação do laser de Er:YAG com os cimentos de ionômero de vidro e o grupo que obteve o melhor desempenho através da análise estatística foi o que utilizou o laser com a energia de preparo e restaurado com o Vitremer. Baseados nos achados nas condições experimentais utilizadas concluímos que a cárie radicular deve ser tratada pela associação da remoção de tecido cariado com o laser de Er:YAG no parâmetro de preparo com a restauração da cavidade com o cimento de ionômero de vidro modificado. / Failures of root caries restoration such as microinfiltration and secondary caries are mostly due to the difficult to reach the lesions and to the types of substrate. Thus, there is a constant search for new dental materials and caries removal techniques in order to minimize or extinguish these failures. The aim of this study was to induce root caries in vitro for testing the marginal sealing capacity of two glass ionomer cements (Ketac Fill Plus e Vitremer) applied these caries cavities prepared with Er:YAG laser irradiation. Forty-five human teeth were used (molars and premolars). After the in vitro root caries induction using S. mutans the caries lesions were removed by three different methods: Er;YAG laser irradiation at the dentin preparation parameters (250 mJ, 4 Hz, 80.6 J/cm2); or the irradiation with this dentin preparation parameters followed buy a surface conditioning parameters (60 mJ e 2 Hz, 19,2 J/cm2); or by the conventional technique using burs (control). Three teeth of each group were prepared for scanning electron microscopy morphological observation. Thirty-six teeth were divided into six groups (six teeth per group) according to the type of cavity preparation (3) and the cement used in the restoration (2). After the restoration the samples were thermocycled (1,000) cycles and prepared for the microinfiltration test. The sealing was measured by the degree of the 2% methylene blue solution infiltration and these results were transformed into scores. The data in triplicate were compared by statistical test of Kruskall-Wallis complemented by the Dunn’s test. The better scores were observed at the groups treated by the Er:YAG laser irradiation and the best result was obtained using the Er:YAG laser at the dentin preparation parameter followed by the restoration of the 10 cavity with the modified glass ionomer (Vitremer). Based on the results at the experimental conditions used we concluded that dental root caries should be removed by Er:YAG laser irradiation and restored with the modified glass ionomer.
256

Capacidade de selamento de três materiais retrobturadores frente à infiltração microbiana por Enterococcus faecalis / Sealing ability of three root-end filling materials front to the microbial leakage by Enterococcus faecalis

Luciana Carvalho Reis 02 February 2010 (has links)
O objetivo deste estudo foi comparar a capacidade de selamento apical de três materiais retrobturadores em dentes submetidos à infiltração microbiana por Enterococcus faecalis. Além de analisar a ocorrência da infiltração microbiana em relação à variável tempo. Para tal, foram utilizados 80 caninos superiores permanentes humanos extraídos, instrumentados com o sistema rotatório ProTaper Universal (MAILLEFER) e obturados pela técnica de compactação lateral, com dois tipos de cimento endodôntico: Endofill (DENTSPLY) e AH Plus (DENTSPLY). A apicetomia foi realizada com a remoção de 3mm do terço apical e o retropreparo confeccionado com pontas ultrasônicas. As amostras foram subdivididas, aleatoriamente, em 6 grupos com 10 dentes cada, e 2 grupos controles. Os materiais utilizados para a retrobturação foram MTA branco (ANGELUS), IBC BioAggregate (INNOVATIVE BIOCERAMIX INC.) e Acroseal (SEPTODONT). Foram confeccionados dispositivos para fixação dos dentes aos tubos Eppendorfs. As amostras foram inoculadas com cepas de E. faecalis e incubadas a 37C, por um período de 90 dias, para análise da presença de turvação do meio Enterococcosel. Para a realização da análise estatística foram utilizados os seguintes testes: Qui-quadrado com Prova Exata de Fisher e Kruskal-Wallis. Os resultados mostraram que todos os grupos nos quais foi realizada a obturação e a posterior retrobturação apresentaram infiltração. Comparando todos os grupos, não houve diferença significativa entre os materiais testados. Em relação apenas aos materiais retrobturadores, o Acroseal obteve a menor infiltração, seguido do MTA branco e do IBC BioAggregate. As amostras obturadas com o cimento Endofill não apresentaram diferença estatística em relação à variável tempo. Porém, nas amostras obturadas com o cimento AH Plus, houve maior ocorrência de infiltração nas amostras retrobturadas com o IBC BioAggregate e menor infiltração nas amostras retrobturadas com Acroseal, com diferença estatisticamente significante ao nível de 10%. / The objective of this study was to compare the apical sealing ability of three root-end filling materials in teeth submitted to the microbial leakage by Enterococcus faecalis. Besides analyzing the occurrence of the microbial leakage in relation to the variable time.For such, 80 canine permanent superior teeth extracted from humans were used, which were instrumented with ProTaper Universal system (MAILLEFER) and filled by the lateral compaction technique, with two types of endodontic sealers: Endofill (DENTSPLY) and AH Plus (DENTSPLY). The apices were resected with the removal of 3mm of the apical third and the root-end cavities prepared with ultrasonic tips. The samples were subdivided, randomly, in 6 groups with 10 teeth each, and 2 control groups. The materials used for the retrofilling were white MTA (ANGELUS), IBC BioAggregate (INNOVATIVE BIOCERAMIX INC.) and Acroseal (SEPTODONT). Devices were made for fixation of the teeth to the Eppendorf tubes. The filling samples were inoculated with strains of E. faecalis and incubated at 37C, for a period of 90 days, for analysis of the presence of turbidity of Enterococcosel medium. For the accomplishment of the statistical analysis the following tests were used: Qui-square with Exact Proof of Fisher and Kruskal-Wallis. The results showed that all the groups in which the filling was accomplished and the subsequent retrofilling presented leakage. Comparing all groups, there was not significant difference among the tested materials. In regard to only the root-end filling materials, Acroseal obtained the smallest leakage, followed by white MTA and IBC BioAggregate. The samples filled with the sealer Endofill didn't present statistical difference in relation to the variable time. However, in the samples filled with the sealer AH Plus, there was larger leakage occurrence in the samples retrofilled with IBC BioAggregate and smaller leakage in the samples retrofilled with Acroseal, with statistically significant difference at a 10% level.
257

Latossolo húmico sob diferentes usos no agreste meridional de Pernambuco : atributos químicos, físico-hidricos e biológicos

BEZERRA, Cidney Barbosa 25 August 2016 (has links)
Submitted by Mario BC (mario@bc.ufrpe.br) on 2017-02-22T13:08:59Z No. of bitstreams: 1 Cidney Barbosa Bezerra.pdf: 2167272 bytes, checksum: 5f0cef27593c95187e77811cdb520cbb (MD5) / Made available in DSpace on 2017-02-22T13:08:59Z (GMT). No. of bitstreams: 1 Cidney Barbosa Bezerra.pdf: 2167272 bytes, checksum: 5f0cef27593c95187e77811cdb520cbb (MD5) Previous issue date: 2016-08-25 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The South Agreste Pernambucano has an agricultural and very large land diversification, but the management of the soil used in the production is mostly inadequate, resulting in economic and low productivity losses, allied to it have weather conditions quite different typical of a transitional environment . However the city of Brejão has a special condition with cooler and rainy weather and deeper soils and well structured, with occurrence horizon latosols with the humic something characteristic in this swamp of altitude. So the aim of this study was to investigate the changes in chemical, physical and water attributes of the surface horizon humic an Oxisol subjected to different forms of management in the Swamp region of South Agreste Altitude Pernambuco, and investigate the soil repellency water. The disturbed and undisturbed soil samples were collected in a native forest (MN), pasture 5 years (PA5) and grazing 30 (PA30) in three layers 0 to 10 cm, 10 to 20 cm and 20 to 30 cm and evaluated the chemical, biological, physical and water attributes, as was also done an infiltration test with simple ring. Chemical attributes presented typicality dystrophic yellow latosols, and attributes related to the acidity showing significant results mainly in the surface layer. For biological attributes your changes are more significant in macroaggregates. Have the physical attributes that most change with inadequate management are the bulk density (Ds) and porosity consequently these physical attributes are linked to water retention in the soil and all water dynamics. For the infiltration test it is clear the presence of soil water repellency. / O Agreste Meridional pernambucano possui uma diversificação agropecuária e de solos muito grande, porém o manejo do solo empregado na produção é em sua maioria inadequado, acarretando em perdas econômicas e baixa produtividade, aliadas a isso temos condições climáticas bastante diferentes típicas de um ambiente de transição. No entanto a cidade de Brejão possui uma condição especial, com clima mais frio e chuvoso e solos mais profundos e bem estruturado, com ocorrência de latossolos de horizonte com A húmico algo característico nesse brejo de altitude. Assim o objetivo deste trabalho foi investigar as alterações nos atributos químicos, físicos e hídricos do horizonte superficial A húmico de um Latossolo Amarelo submetido a diferentes formas de manejo na região do Brejo de Altitude do Agreste Meridional pernambucano, e investigar a repelência do solo a água. As amostras deformadas e indeformadas do solo foram coletadas em uma área de mata nativa (MN), pasto de 5 anos (PA5) e pasto de 30 anos (PA30), em três camadas 0 a 10 cm, 10 a 20 cm e 20 a 30 cm e foram avaliados os atributos químicos, biológicos, físicos e hídricos, como também foi realizado um teste de infiltração com anel simples. Os atributos químicos apresentaram tipicidade de latossolos amarelo distróficos, e atributos relacionados com a acidez apresentando resultados significativos principalmente na camada superficial. Para os atributos biológicos suas alterações são mais expressivas nos macroagregados. Já os atributos físicos que mais sofreram alterações com o manejo inadequado são a densidade do solo (Ds) e a porosidade, consequentemente esses atributos físicos estão ligados a retenção de água no solo e toda dinâmica hídrica. Pelo teste de infiltração fica claro a presença de repelência do solo a água.
258

Caracterização geológico-geotécnica do lixão desativado de São Carlos-SP, com auxílio da geofísica / Geological-geotechnical characterization of the uncontrolled sanitary landfill of São Carlos-SP

Regiane Velozo 19 June 2006 (has links)
Infelizmente os municípios brasileiros, em sua grande maioria, dispõem seus resíduos sólidos domiciliares sem nenhum controle, o que promove graves conseqüências, como contaminação do ar, do solo, das águas superficiais e subterrâneas. Este trabalho visou caracterizar geológica e geotecnicamente, com base em estudos geofísicos, o lixão desativado de São Carlos - SP, bem como analisar a evolução da contaminação já identificada por alguns autores anteriormente. Os resíduos foram dispostos inadequadamente nesta área por aproximadamente 17 anos, sobre os solos arenosos permeáveis da formação Botucatu. Esta atividade cessou definitivamente em 1996, o que não finalizou o processo de contaminação, ainda atuante. Para investigação da evolução da pluma de contaminação realizaram-se caminhamentos elétricos (eletrorresistividade e polarização induzida), ensaios de infiltração e outros para caracterização dos materiais inconsolidados, associando estes dados aos já existentes. Os resultados mostram que a aplicação dessas técnicas permitiu caracterizar a situação de contaminação atual da área, mostrando que existe a propagação de uma pluma de contaminação com direção NW, e que verticalmente também pode estar ocorrendo contaminação. Essa contaminação no sentido vertical pode ser acentuada pela existência de uma descontinuidade sob o corpo do lixo, pela alta permeabilidade dos materiais arenosos da região, pela ausência de barreiras menos permeáveis e pela variação sazonal do nível d´água. / Unfortunately the brazilian cities, in its majority, discharge its domestic solid wastes without any control, which produces grave consequences such as contamination of the air, earth, and both superficial and the groundwater. This work carried out a geological-geotechnical characterization and geophysical studies of the uncontrolled sanitary landfill of São Carlos – SP, and also the analysis of the evolution of the contamination previously identified by other authors in the area. The residues were disposed inadequately in this area for approximately 17 years, in an area constituted by porous soils overlapping sandstones of Botucatu formation. This practice ceased completely in 1996, but the contamination process didn’t stop up to now. For investigation of the development of the plume of contamination several procedures were used: geophysical surveys (eletroresistivity and induced polarization), infiltration characterization tests of the unconsolidated materials and analysis of the results already existing. The results show that these techniques were enabled to characterizing the current situation of contamination of the area, showing that there is a propagation of a plume of contamination with direction NW, and that there also may be contamination occurring vertically. This contamination on the vertical direction may be allowed by the existence of a discontinuity under the sanitary landfill, high permeability of the sandy materials in the area, by the lack of less permeable layers and by the seasonal variation of the groundwater level.
259

Efeitos da solução salina hipertônica na resposta inflamatória na sepse / Hypertonic saline solution effects in inflammatory response in sepsis

Mariana Cardillo Theobaldo 11 October 2012 (has links)
Sepse é a resposta inflamatória sistêmica do hospedeiro à infecção, que pode ser desencadeada por bactérias, vírus ou fungos. Há aumento da produção de mediadores inflamatórios como citocinas, quimiocinas espécies reativas de oxigênio e do recrutamento de neutrófilos. A administração de solução salina hipertônica 7,5% (SH) acarreta na modulação da resposta inflamatória e hemodinâmica culminando na redução da morbidade e mortalidade em modelos de pancreatite e choque hemorrágico. No presente trabalho, estudamos os efeitos da SH na sepse, induzida por ligadura e perfuração cecal (CLP) em camundongos Balb/C, divididos em 3 grupos: CLP sem nenhum tratamento (CLP); CLP tratado com solução salina isotônica 0,9% (SS) e CLP tratado com SH 7,5% (SH); um quarto grupo foi utilizado como controle, no qual não foi induzido sepse ou administrado tratamento (C); ambos os tratamentos foram aplicados 30 min. após CLP. Lavado peritoneal, intestino e pulmão foram coletados após 6h, 12h e 24h para a análise de citocinas (TNF-, IL-6 e IL-10), produção de oxido nítrico, peroxidação lipídica, infiltração de neutrófilos, moléculas de adesão (ICAM-1 e VCAM-1) e quimiocinas (CXCL-1). O grupo SH mostrou aumento de sobrevida (60%) em comparação aos grupos SS (46,6%) e CLP (33,3%) após 168h. SS apresentou aumento na produção de TNF- (27,3 ± 3,05 pg/ml) em 12h comparado ao grupo CLP (14,07 ± 1,68 pg/ml) e SH (19,66±3,19pg/ml); O efeito da SH na concentração de TNF permanece até 24h (6,2 ± 3,5 pg/ml vs. CLP 73,40± 49,52 pg/ml); a produção de IL-10 em 24h aumentaram nos grupos CLP (CLP - 3,12 ± 0,46 pg/ml) e SS (2,9 ± 0,9 pg/ml) em relação ao grupo SH (0,59 ± 0,34 pg/ml). Em 24h a produção de nitrito mostrou-se reduzida no grupo SH (6,77 ± 0,82 pg/ml) comparado com SS (10,65 ± 1,08 pg/ml), no pulmão. No intestino, a produção de nitrito, em 6h, diminuiu no grupo SH (1,27 ± 0,19 pg/ml) comparado com CLP (2,44 + 0,51 pg/ml). No grupo SH houve redução do infiltrado de neutrófilos no pulmão em 24h, através da redução de moléculas de adesão e concentração de mieloperoxidase, em comparação com CLP (29,4 + 5,7 ng/mg ; 3,02 + 0,41 mU/mg). Nossos resultados indicam que SH modula a resposta inflamatória, além de melhorar a sobrevida de animais submetidos à sepse experimental / Sepsis is a systemic inflammatory response to infection triggered by bacteria, virus and fungi. There is a rise in inflammatory mediators as citokynes, chemokynes, reactive oxygen species and neutrophil recruitment (1). The hypertonic saline solution (SH) has been showed to improve hemodynamic and inflammatory response. We studied the hypertonic solution effects in sepsis through cecal ligation and puncture (CLP) in mice Balb-C, divided in 3 groups: CLP without treatment (CLP); CLP treated with isotonic saline solution 0,9% - 34mg/Kg (SS); CLP treated with hypertonic saline solution 7,5% - 4ml/Kg (SH); and a 4th group indicating the basal values without both CLP and treatment (C); both treatments were administrated 30 min after CLP. The lung, gut and peritoneal fluid were collected after 6h, 12h and 24h to analyze cytokines levels, oxide nitric, lipid peroxidation and neutrophil infiltration. The SH group showed higher survival rats (60%) when compared to SS (46,6%) and CLP (33,3%) after 168h (7 days). TNF- level in the SS group (27,3 ± 3,05 pg/ml) was increased at 12h when compared to CLP (14,07 ± 1,68 pg/ml) and SH (19,66±3,19pg/ml); and at 24h the SH (6,2 ± 3,5 pg/ml) decreased its level when compared to CLP (73,40± 49,52 pg/ml); IL-10 level at 24h was increased in CLP (CLP - 3,12 ± 0,46 pg/ml) and SS (2,9 ± 0,9 pg/ml) in relation to SH (0,59 ± 0,34 pg/ml). In 24h, the quantification of nitrite decreased in SH (6,77 ± 0,82 pg/ml) compared with SS (10,65 ± 1,08 pg/ml) in lung. In intestine, nitrite levels diminished in SH (1,27 ± 0,19 pg/ml) in relation to CLP (2,44 + 0,51 pg/ml) in 6h. SH group reduced the neutrophil infiltration in lung, through adhesion molecule and myeloperoxidase at 24h (ng/mg;1,49 + 0,24 mU/mg) in relation to CLP(29,4 + 5,7 ng/mg ; 3,02 + 0,41 mU/mg). Our results suggest that the volume replacement of both treatments modulate pro and anti-inflammatory mediators of an inflammatory response to infection, but hypertonic solution presented a more effective effect
260

Dinâmica da água em terraços de infiltração. / Water dynamics in level terraces.

Luciana Gomes Castro 14 December 2001 (has links)
O terraceamento é uma prática de conservação do solo que visa reduzir a perda de água e solo pela interceptação de enxurradas que ocorrem quando a intensidade da chuva supera a capacidade de infiltração de água no solo. Atualmente, o dimensionamento dos terraços tem sido feito com base em conhecimento empírico; no entanto, um conhecimento mais detalhado da física dos processos que regem o funcionamento dos terraços possibilitaria otimizar o dimensionamento dos terraços. No presente estudo foi avaliada a capacidade de infiltração de água no canal de um terraço em nível pelos métodos da densidade de fluxo e da armazenagem de água em diferentes condições de manejo agrícola (solo nu, solo gramado e solo sob preparo convencional e plantio direto para a implantação da cultura de milho) num Latossolo vermelho com declividade média de 0,08 m m-1. Em cada tratamento foram instaladas sondas de TDR em três pontos de observação no centro do canal do terraço (distanciados de 4 m entre si e considerados como repetições), nas rofundidades de 0,05, 0,10, 0,20, 0,40, 0,60 e 0,80 m. Nestas mesmas profundidades amostras indeformadas de solo foram retiradas para determinação da densidade e curva de retenção de água no solo. As leituras das guias de onda do TDR foram feitas automaticamente e a intensidade de chuva monitorada por um pluviômetro automatizado. Ao final de cada evento de chuva erosiva a deposição de solo foi medida por meio de 14 pontos de observação dispostos ao longo do centro do canal do terraço de cada tratamento. Durante a estação seca (julho-agosto), a condutividade hidráulica do solo não saturado foi determinada em cada repetição nas mesmas profundidades, utilizando o método do perfil instantâneo. Os resultados demonstraram que os manejos agrícolas influenciam na deposição de água e solo sobre o canal do terraço e estas na formação de selo superficial e na capacidade de infiltração de água do canal. Conclui-se que a alta variação comumente obtida entre as repetições de determinação da condutividade hidráulica implica em dificuldades quando se objetiva detectar pequenas diferenças nas densidades de fluxo entre tratamentos. Assim, mostrou ser inviável utilizar densidades de fluxo calculadas pela equação de Darcy-Buckingham para encontrar diferenças em taxas de infiltração em terraços em nível. Essa conclusão reforça-se devido às condições superficiais altamente variáveis encontradas em canais de terraços em nível devido a deposições irregulares do material erodido. Uma metodologia para se realizar medições da umidade nas deposições sobre o canal deve ser desenvolvida para aumentar a acurácia da medida da armazenagem. A taxa de infiltração de água no canal do terraço não pode ser estimada pela variação da armazenagem da água no solo somente, devido ao papel importante da drenagem profunda e, possivelmente, da absorção de água pela camalhão do terraço. Uma adequada estimativa da taxa de infiltração no canal do terraço, imprescindível para seu dimensionamento, deve aliar um grande número de repetições, além da medição da umidade no interior da camada de material depositado sobre o canal ao longo do tempo. / Terracing is a soil conservation practice that aims to reduce water and soil loss by interception of runoff that occurs when rainfall intensities exceed infiltration capacity. Actually, dimensions of terraces are being determined in an empirical way; however, a more detailed understanding of the physics behind the hydrological functions of terraces would allow an optimized dimensioning of terraces. In this study the infiltration capacity of a level terrace was evaluated by the methods of flux density and water storage, under different management conditions (bare soil, pasture, conventionally tilled maize and zero-tillage maize) on an oxisol with a slope of 0.08 m m-1. In each treatment TDR sensors were installed at three observation points in the middle of the terrace canal (distance between points: 4 m; considered to be repetitions) at the depths of 0.05, 0.10, 0.20, 0.40, 0.60 and 0.80 m. At the same depths, undisturbed soil samples were taken to determine soil density and soil water retention curve. TDR readings were made automatically and a rainfall gauge automatically monitored rainfall intensity. At the end of each rainfall event, soil deposition was measured at 14 locations in the terrace canal in each treatment. During the dry season (July-August), unsaturated hydraulic conductivity was determined at each repetition at the same depths by the instantaneous profile method. The results showed that agricultural management influenced water and soil deposition in the terrace canal and these affected surfaced sealing and infiltration capacity. It was concluded that the high variation usually obtained between repetitions of the hydraulic conductivity determinations makes the detection of small differences between flux densities difficult. Therefore, it showed to be impossible to use flux densities calculated by Darcy-Buckingham equation in the order to prove existence of different infiltration rates in level terraces. This conclusion was reinforced due to the highly variable surface conditions in the terrace canal. A methodology to measure water contents within the depositions in the canal should be developed to increase the precision of water storage estimation. Infiltration rates in the terrace canal cannot be estimated by storage variation alone, due to the important role of drainage and, possibly, ascension of water in the terrace hill. A correct estimate of the infiltration rate in the canal, necessary for its dimensioning, should combine a high number of repetitions with the measurement of water content within the layer of deposits over the terrace canal surface along time.

Page generated in 0.062 seconds