• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1055
  • 377
  • 29
  • 22
  • 22
  • 22
  • 18
  • 12
  • 10
  • 9
  • 5
  • 5
  • 4
  • 4
  • 2
  • Tagged with
  • 1489
  • 458
  • 225
  • 218
  • 200
  • 188
  • 173
  • 172
  • 172
  • 172
  • 172
  • 154
  • 150
  • 136
  • 135
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

Rainhas, mestres e tambores : gênero, corpo e artefatos no maracatunação pernambucano

Maria Oliveira, Jailma 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T15:06:57Z (GMT). No. of bitstreams: 2 arquivo7162_1.pdf: 4342917 bytes, checksum: b84435bdc6e641e4cd48a268d7b8bd48 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2011 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O trabalho tentou compreender as relações de gênero nos grupos de maracatu-nação do Recife e Região Metropolitana. Desdobrou-se para as noções de corporeidade, sinalizando para constituições de subjetividades de homens e mulheres. Baseia-se em trabalho de campo iniciado em outubro de 2009 até fevereiro de 2010, incluindo observação de ensaios e desfiles carnavalescos, entrevistas, documentos das instituições estaduais de cultura e a produção dos folcloristas. Os grupos de maracatu usam as fontes históricas para compor uma compreensão e avaliação da sua tradição. É um cortejo realizado com musica e dança, estruturado em corte e batuque, para celebrar a coroação do casal real e as divindades afro-brasileiras e/ou os antepassados negros. A corte simboliza o poder do sagrado, classificada como feminina, o batuque é masculino, encarnando um poder temporal, divisão que aparenta uma neutralidade de gênero com distribuição relativamente equitativa de poder. Entretanto, no nível das práticas, geramse disputas entre mestres (símbolo do batuque) e rainhas (símbolos da corte), consoante ocupem a posição de presidente dos grupos. Os instrumentos são classificados por gênero e demandam performances corporais adequadas, independente se quem executa é homem ou mulher, rebatendo na constituição de subjetividades de homens e mulheres. A inclusão de homens travestidos reforça estes aspectos dentro do maracatu
152

Um estudo sobre os efeitos no patrimônio e resultado dos bancos brasileiros decorrentes da adoção do ajuste ao valor de mercado

CORDEIRO, Josimar Farias 31 January 2010 (has links)
Made available in DSpace on 2014-06-12T17:35:37Z (GMT). No. of bitstreams: 2 arquivo2729_1.pdf: 1548654 bytes, checksum: bdeb0c082c04e69041adcf66305391ca (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2010 / Este trabalho aborda o reconhecimento e mensuração dos instrumentos financeiros, especificamente os títulos e valores mobiliários e tem como objetivo principal investigar a existência de efeitos estatisticamente significativos no patrimônio e resultado de Instituições Financeiras Bancárias após alterações das normas e procedimentos contábeis locais (BR GAAP), advindas Circular do BACEN 3.068/2001, no que concerne à adoção do ajuste a valor de mercado. Foram empregadas como tipologias: a pesquisa bibliográfica, exploratória, descritiva, quantitativa e qualitativa na elaboração do trabalho. O método utilizado foi o indutivo por meio da análise documental dos Balanços Patrimoniais e Demonstrações do Resultado do Exercício de 06 Instituições Financeiras Bancárias, através de índices relativos aos Títulos e Valores Mobiliários. Onde se teve como série temporal para análise dos demonstrativos os anos anteriores e posteriores a Circular supracitada, ou seja, antes e a partir do ano de 2002 (marcação a mercado). Através da estatística do teste t para igualdade de médias e do teste t pareado, foi constatado que não existem diferenças significativas nos Títulos e Valores mobiliários nos anos anteriores e posteriores à Circular do BACEN 3.068/2001. Ou seja, não existem efeitos significativos no patrimônio e no resultado dos bancos devido à mudança dos critérios de mensuração e reconhecimento dos instrumentos financeiros para valor de mercado
153

Influência da geometria de canais curvos simulados no número de ciclos até a fratura (NCF) instrumentos RECIPROC®

DONIDA, Fernanda Araújo 21 January 2015 (has links)
Submitted by Isaac Francisco de Souza Dias (isaac.souzadias@ufpe.br) on 2016-05-13T17:31:08Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação Fernada Araujo Donida.pdf: 957390 bytes, checksum: d11f710a969f4e48e2e9d3e6cf89c088 (MD5) / Made available in DSpace on 2016-05-13T17:31:08Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação Fernada Araujo Donida.pdf: 957390 bytes, checksum: d11f710a969f4e48e2e9d3e6cf89c088 (MD5) Previous issue date: 2015-01-21 / CAPES / Objetivo Avaliar a influência da geometria de canais curvos simulados no número de ciclos até a fratura (NCF) de instrumentos Reciproc®. Metodologia Foram confeccionados quatro canais simulados em aço inoxidável com geometrias diferentes variando o comprimento de arco, o raio de curvatura e a posição da curvatura radicular. Uma plataforma de suporte da peça de mão também foi confeccionada em aço inoxidável com o objetivo de coincidir a trajetória vertical do instrumento instalado na peça de mão com o eixo longitudinal da parte reta do canal simulado. Foram selecionados 40 instrumentos R25, alocados por sorteio em 4 grupos (A, B, C e D), de maneira que cada grupo foi instrumentado com 10 amostras cada. Os ensaios de fadiga foram realizados e o tempo decorrido até a visualização da fratura ocorrer foi cronometrado. O número de ciclos até a fratura (NCF) foi obtido pela multiplicação da velocidade de rotação, em segundos, pelo tempo decorrido até a fratura em flexão rotativa da cada instrumento, também em segundos. Os resultados obtidos foram submetidos ao teste estatístico de Mann-Whitney, com 95% de confiança (p≤0,05). Resultados Ao comparar a geometria do Canal A com Canal B o instrumentos R25 obteve um maior número de ciclos até a fratura no canal A. Comparando o Canal A ao Canal C, foi constatado que o instrumento R25 é mais resistente quando utilizado em canais com raios maiores. Ao comparar o Canal A com o Canal D, foi comprovado que, os instrumentos R25 se mostraram mais resistentes quando utilizados em canais com um menor comprimento de arco. Conclusão A intensidade do estresse sobre o instrumento aumenta à medida que o raio da curvatura diminui, ou quando se aumenta o comprimento do arco, como também quando o arco esta localizado na porção coronária do canal. / Aim To evaluate the influence of simulated curved canals geometry in the number of cycles to failure (NCF) of Reciproc® instruments. Methodology Four Stainless steel simulated channels with different geometries were made by varying the arc length, the radius of curvature and the position of the root curvature. A hand piece support platform was also made of stainless steel in order to match the vertical trajectory of the instrument installed in the handpiece to the longitudinal axis of the straight part of the simulated canal. Forty (40) R25 instruments were select, allocated by lot in 4 groups (A, B, C e D) of 10 samples each. The fatigue tests were performed and the time until the fracture could be visualized was chronometrically measured. The number of cycles to fracture (NCF) was obtained by multiplying the rotation speed, in seconds, by the time until fracture of each rotating bending tool, also in seconds. The results were submitted to the statistical Mann-Whitney test, with 95% confidence (p≤0,05). Results By comparing the geometry of the channel A to channel B, R25 instruments obtained a larger number of cycles to fracture comparing the channel A. Comparing Channel A to Channel C, it was found that the R25 instrument is more resistant when used in channels with larger ratius. When comparing Channel A with Channel D, it was proven that the R25 instruments were more resistant when used in channels with a shorter arc length. Conclusions The intensity of stress on the instrument increases as the radius of curvature decreases, as the arc length increases, as well as when the arc is located on the coronal portion of the channel.
154

Avaliação da influência de diferentes tióis no desempenho de biossensores magnetielásticos para detecção de escherichia coli

Pozza, Márcia Dalla 12 December 2016 (has links)
Os métodos de detecção de patógenos, em geral, requerem dias para identificação de micro-organismos patogênicos, havendo interesse em uma detecção rápida e precisa em tempo real, os biossensores magnetoelásticos são uma alternativa promissora. Os sensores magnetoelásticos são dispositivos de detecção que podem ser acessados remotamente e sua aplicação no método de biossensoriamento possui sensibilidade mássica para espécies biológicas, oferecendo confiabilidade na detecção de patógenos como Escherichia coli. Neste trabalho, tiras amorfas Metglas 2826MB3 foram revestidas com Au pelos processos de deposição de sputtering e eletrodeposição e segmentadas em lâminas de 5 x 1 mm. Foram avaliados os parâmetros de rugosidade média absoluta (Ra), desvio padrão das alturas da superfície (Rq) e simetria do perfil de distribuição (Rsk) com a técnica de microscopia de força atômica aplicada em três superfícies distintas (lisa, rugosa e polida). Buscando melhorar a sensibilidade de detecção do dispositivo, avaliou-se a influência de diferentes tióis no desempenho de biossensores magnetoelásticos. Os compostos utilizados diferem no tamanho da cadeia carbônica e no grupamento terminal que liga-se ao anticorpo. Sobre a superfície polida revestida com Cr/Au pelo processo de sputtering depositou-se os compostos cistamina (CYS), cisteamina (CYSTE) e ácido mercaptopropiônico (MPA), seguido por anticorpos. Os biossensores foram expostos a solução de bactéria E. coli e a variação da frequência de ressonância foi medida com um analisador de rede. Foi possível constatar que a superfície polida revestida com Cr/Au pelo processo de sputtering apresentou menores valores de Ra e Rq e melhor perfil de distribuição (Rsk) em relação às demais superfícies estudadas. Os biossensores com o composto MPA mostraram um aumento na captação de bactérias em relação aos biossensores com os compostos CYS e CYSTE, porém altos valores de desvio padrão foram observados, dificultando a reprodutibilidade e confiabilidade do biossensor. Os biossensores testados com CYSTE apresentaram maior eficiência e menor limite de detecção em relação aos biossensores testados com CYS, apontando um melhoramento na utilização deste composto. Os resultados foram favoráveis para a detecção da bactéria E. coli, evidenciando que o tamanho da cadeia carbônica e o grupamento terminal influenciam na eficácia da imobilização deste patógeno em biossensores magnetoelásticos. / Conselho Nacional de Desenvolvimento Científico e Tecnológico, CNPq. / The magneto-elastic sensors are detection devices that can be remotely accessed and applied as biosensors having a mass sensitivity for detection of biological specimens, offering reliability in the detection of pathogens such as Escherichia coli. The pathogen detection methods generally require days to identify the pathogenic micro-organism, so there is interest in a rapid and accurate detection in real time. The magneto elastic biosensors are a promising alternative for this task. In this work, amorphous ribbons of Metglas 2826MB3 were coated with Au by the processes of sputtering and electrodeposition and segmented into 5 x 1 mm strips. We evaluated the roughness parameters arithmetic average height (Ra), root mean square roughness (Rq) and skewness (Rsk) using atomic force microscopy applied on three different surfaces (smooth, rough and polished). Seeking to improve the detection sensitivity of the device, the performance of the biosensors was evaluated in terms of the effects of different thiols on their performance. The compounds used differ in the size of the carbon chain and the terminal grouping which binds to the antibody. On the polished surface coated with Cr/Au by sputtering, we deposited the compounds cystamine (CYS), mercaptopropionic acid (MPA) and cysteamine (CYSTE), followed by antibodies. The biosensors were exposed to the bacteria E. coli in solution and the variation of the resonance frequency was measured with a network analyzer. It was found that the polished surface coated with Cr/Au by sputtering process showed lower values of Ra and Rq and a better distribution profile (Rsk) in relation to other surface studied. Biosensors employing the compound MPA showed an increase in attracting bacteria in relation to biosensors with CYS and CYSTE, but high standard deviations were observed, thus hampering the reproducibility and reliability of the biosensor. Biosensors tested with CYSTE showed higher efficiency and lower detection limit with respect to biosensors tested with CYS, indicating an improvement in the use of this compound. The results were favorable for the detection of E. coli, indicating that the size of carbon chain and the terminal grouping influence the effectiveness of immobilization of the magneto elastic biosensors.
155

Efeito de brocas para implantes sobre o tecido osseo : estudo histologico em cães

Couto Filho, Carlos Eduardo Gomes do, 1962- 23 July 2018 (has links)
Orientador: Luis Augusto Passeri / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-23T11:31:04Z (GMT). No. of bitstreams: 1 CoutoFilho_CarlosEduardoGomesdo_M.pdf: 4440845 bytes, checksum: 9f293372bb6de2d09bc9aee2f8bb3e69 (MD5) Previous issue date: 1998 / Resumo: o sucesso do tratamento, através da colocação de implantes, exige leitos receptores adequados, para que ocorra uma osseointegração ideal. O equipamento utilizado para a confecção destas cavidades deve ser o mais preciso possível, devendo promover cortes com paredes bastante regulares e sem áreas de necrose. Com o objetivo de avaliar histologicamente, o efeito das brocas para implantes sobre o tecido ósseo utilizou-se sete cães, confeccionando-se, na mandibula de cada um deles, orifícios para colocação de implantes, seguindo a seqüência de brocas sugerida pelos fabricantes dos sistemas Nobel Biocare, ImpJamed e 3i. Após a confecção das cavidades, removeu-se o fragmento ósseo, e executou-se cortes semi-seriados de 6 f.lIll, no sentido don longo eixo dos cortes, e coloração com hematoxilina e eosina. A avaliação microscópica mostrou cortes regulares com poucas áreas de necrose e esquírolas ósseas, evidenciando que a técnica utilizada foi adequada, atestando a qualidade das brocas / Abstract: The success of the treatment through the placement of osseointegrated implants will require appropriate cavities so it happen an ideal osseointegration. The equipment that was needed to make these cavities must be the most accurate promoting holes with uniform wall and without necrosls area. With intention to avaluate the histollogical effects of burs over the osseous tissue it was used eight dogs, made in the lower jaw holes to place the implants following the sequence of burs suggested by manufacturers After the holes were made the osseous fragments were removed and made semiseriate .incisions of 6 JlIIl following the long axis of the holes and stained with heinatoxiline and eosine A microscopic avaluation showed sharp incision, few necrosis area and bone fragments meaning that applied technique was adequated and proving the quality of the burs / Mestrado / Mestre em Odontologia
156

Pressão lateral em formas para concreto

Cruz, Rosana Maximo da 24 June 1998 (has links)
Orientador: Mauro Augusto Demarzo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-07-23T18:42:57Z (GMT). No. of bitstreams: 1 Cruz_RosanaMaximoda_M.pdf: 3857368 bytes, checksum: 4b501cefb73b6e9e5ba8f89456652ebe (MD5) Previous issue date: 1997 / Resumo: Neste trabalho, estudou-se as pressões laterais causadas pelo lançamento do concreto fresco nas fôrmas. Analisou-se alguns fatores os quais influenciam no comportamento dessas pressões. Foram estudados vários trabalhos de pesquisadores que desenvolveram expressões para o cálculo de pressões laterais, onde o produto da densidade do concreto pela altura é considerada, em algumas expressões, como limite máximo dessa pressão. Com os resultados dos ensaios, foi feita a análise estatística da influência das variáveis abatimento do concreto e velocidade de lançamento do concreto, no comportamento das pressões laterais, em várias alturas. Encontrou-se, então, uma expressão geral, em função dessas variáveis e da altura de concreto lançado. Avaliou-se a confiabilidade do ensaio proposto para determinação das pressões ao longo da altura da fôrma / Abstract: In this work the lateral pressures caused by placement of the fresh concrete in the formwork has been investigated. Some factors that have influenced the behaviour of these pressure were analysed. Several research works conceming equations for the lateral pressure calculation, which consider the density product of the concrete by the height as maximum limit of this pressure, were studied. With the test results, it was statistically analyzed the influence of the variables slump and concrete pour rate, on the lateral pressure behaviour, in several heights. With these variables and the height of placed concrete, a general equation was found. The reliability of the proposed test to determine the pressures along the formwork height was analyzed. / Mestrado / Estruturas / Mestre em Engenharia Civil
157

Analise da rugosidade radicular apos instrumentação periodontal : estudo "in vitro"

Martins, Eleonora de Oliveira Bandolin 26 July 2001 (has links)
Orientadores : Antonio Wilson Sallum, Enilson Antonio Sallum / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T23:28:26Z (GMT). No. of bitstreams: 1 Martins_EleonoradeOliveiraBandolin_D.pdf: 5329012 bytes, checksum: 0abd0bd9fc5363f22c6576baea267c8f (MD5) Previous issue date: 2001 / Resumo: O objetivo deste trabalho foi avaliar, in vitro, o grau de rugosidade radicular produzido pelos vários tipos de instrumentos utilizados durante o processo de instrumentação. Foram selecionados 110 dentes humanos extraídos. Estes dentes foram lavados em água corrente e acondicionados em recipientes com formol para serem manipulados todos ao mesmo tempo, por um único operador. Os dentes foram divididos aleatoriamente, em 11 grupos instrumentados com curetas Gracey; lima periodonta1; aparelho ultra-sônico; aparelho sônico; broca diamantada extra-fina, em caneta de alta e baixa-rotação; broca carbide multilaminada de 12 e 30 lâminas, em caneta de alta e baixa rotação; e grupo controle, sem instrumentação. Foram realizadas três leituras paralelas e três perpendiculares ao sentido de instrumentação, em cada amostra antes e depois da instrumentação, utilizando um aparelho rugosímetro. Os dados foram analisados estatisticamente pelos teste '1;" pareado e ANOV A. Os resultados mostraram que o uso de todos os instrumentos produziram aumento de rugosidade na superfície radicular. As pontas diamantada extra-finas utilizadas em alta-rotação produziram o menor aumento de rugosidade em relação ao grupo controle, seguido em ordem crescente de rugosidade pelos seguintes instrumentos: lima periodontal manual, cureta Gracey manual, broca de 30 lâminas em alta-rotação, ponta diamantada em baixa-rotação, broca de 12 lâminas em alta rotação, broca de 30 lâminas em baixa-rotação, broca de 12 lâminas em baixa-rotação, aparelho sônico e aparelho ultra-sônico. Foram também realizadas fotomicrografias das superfícies radiculares, após a instrumentação, em microscopia eletrônica de varredura, com aumento de 150 e 350 vezes, com fins ilustrativos / Abstract: The aim of this study was to evaluate the "in vitro" roughness degree generated by several instruments used for root planning. 110 extracted human teeth were selected. The teeth were washed and stored in formaline, to be manipulated all at the same time by only one person. Then, they were randomly divided into 11 groups and scaled with gracey hand curette, hand periodontal file, ultrasonic scaler, sonic sca1er, fine-grit-diamond bur with high and low-speed headpiece, 12 and 30-1amina bur with high and low-speed hand piece, and control group without instrumentation. Three parallel readings and 3 perpendicular readings were made on the instrumentation direction in the samples before and after instrumentation, with the use of a porfilometer. It was made a statistical data analysis through the doble "t" and ANOV A tests. The results showed that the fine-grit-diamond bur with high-speed hand piece had the lowest values of roughness increase in relation to the control group, followed by the groups: hand periodontal file; hand curette ; 30-lamina bur with high-speed hand piece; fine-grit-diamond bur with low-speed hand piece; 12-lamina bur with high-speed hand piece; 30-lamina bur with low-speed headpiece; 12-lamina bur with low-speed hand piece; sonic scaler and ultrasonic sca1er. Photomicrographs in scanning electron microscopy were taken for illustration, with 150 and 350 times of magnitude / Doutorado / Periodontia / Doutor em Clínica Odontológica
158

Contratos administrativos: a busca da consensualidade para a devida execução, prevenção e resolução de conflitos, na perspectiva do Poder Público

Ribeiro, Graciela Renata January 2014 (has links)
Submitted by Haia Cristina Rebouças de Almeida (haia.almeida@uniceub.br) on 2016-05-05T14:05:03Z No. of bitstreams: 1 61100167.pdf: 1580797 bytes, checksum: 988536563c79bc7039c173648b940447 (MD5) / Approved for entry into archive by Rayanne Silva (rayanne.silva@uniceub.br) on 2016-05-09T18:25:24Z (GMT) No. of bitstreams: 1 61100167.pdf: 1580797 bytes, checksum: 988536563c79bc7039c173648b940447 (MD5) / Made available in DSpace on 2016-05-09T18:25:24Z (GMT). No. of bitstreams: 1 61100167.pdf: 1580797 bytes, checksum: 988536563c79bc7039c173648b940447 (MD5) Previous issue date: 2016-05-05 / O Poder Público para atingir seus fins realiza contratos com particulares e com outros entes do próprio Poder Público. Em casos de inexecução de tais contratos surgem inúmeros desdobramentos. A partir da observação de dificuldades práticas para resolução de impasses decorrentes da inexecução de tais contratos o presente trabalho traz uma abordagem teórica dos contratos administrativos e especificamente dos contratos firmados entre entes do Poder Público para, a partir desta análise, abordar algumas medidas que podem contribuir para a devida execução e para prevenção e resolução de conflitos decorrentes de tais contratos. Uma das medidas propostas é a aplicação de instrumentos consensuais, tais como, a arbitragem, a mediação, a conciliação e a transação administrativa para prevenção e resolução de conflitos contratuais como forma de se primar pela eficiência e evitar a litigância intragovernamental. Diante da relevância e complexidade do tema, para além de apontar possíveis soluções, o objetivo da presente abordagem é trazer o estado do desenvolvimento da matéria no Brasil e destacar a importância de sua criteriosa abordagem na doutrina, legislação e jurisprudência.
159

Desenvolvimento de uma metodologia para codificação de defeitos em equipamentos medicos

Plazas, Rodrigo 02 June 2002 (has links)
Orientador: Saide Jorge Calil / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-02T10:44:28Z (GMT). No. of bitstreams: 1 Plazas_Rodrigo_M.pdf: 5700718 bytes, checksum: 06cde85dbbdd9c4bf55bed085e14df85 (MD5) Previous issue date: 2002 / Resumo: O gerenciamento da Manutenção de Equipamentos Médicos sempre tem sido a atividade básica desenvolvida pela Engenharia Clínica em Instituições de Saúde. Existem dois tipos de documentos: a Ordem de Serviço (O. S.) e o Histórico de Manutenção que se constituem nas principais fontes de informações para elaboração de Relatórios Gerenciais. Dentre os vários itens que compõem estes documentos encontra-se campos para o preenchimento da descrição dos defeitos e serviços executados em equipamentos. O que se vê na prática é que tanto em uma O. S. como em um histórico de manutenção, o preenchimento dos campos relativos à descrição dos defeitos é realizado em linguagem natural, sem qualquer tipo de padronização. É neste contexto que surge a necessidade do desenvolvimento de um sistema para a codificação de falhas que ocorrem em equipamentos médico-hospitalares e que possibilite a padronização das informações relativas a esses defeitos, atribuindo-lhes códigos. Este trabalho propõe uma metodologia para o desenvolvimento de um sistema computacional para a codificação de defeitos em equipamentos médicos. O método utilizado foi dividido em 05 etapas: 1) Revisão Bibliográfica; 2) Pesquisa em Empresas e Centros de Manutenção com sistemas de codificação já implementados; 3) Pesquisa sobre critérios de classificação de equipamentos médicos. 4) Estudo do princípio de funcionamento de equipamentos médicos; 5) Desenvolvimento da Interface Gráfica (Sistema de Codificação de Defeitos em Equipamentos Médicos - SCODEM) para utilização do sistema proposto. Os resultados encontrados em um estudo de caso mostraram que a metodologia é de fácil implementação e utilização, podendo ser aplicada em centros de manutenção / Abstract: The maintenance management of medical equipment have always been the basic activity of Clinical Engineering in Health Institutions. There are two types of documents: Work Order and the Maintenance History, that are the principal source of information to elaborate management accounts. Among the various items that compose this documents, two of them are intended for the description of equipment failures and executed services. Usually these descriptions are executed whit no standards. This brings the need to develop a system for description and codification of failures that occur in medical equipment' s. This work suggest a methodology for the development of a digital system for the codification of failures in medical equipment. The method used in this work was divided in five sections: 1) Bibliography research; 2) Research in companies and maintenance centers with codification system implemented; 3) Research about classification criterion of medical equipments; 4) Study about medical equipment functions; and 5) Software development: SCODEM - System to failures codification in medical equipment's. The resulted work have shown that the methodology is easy to be implemented, utilised and has great adaptability / Mestrado / Mestre em Engenharia Elétrica
160

Avaliação clinica do trauma de instrumentação produzido pela raspagem e alisamento radicular com diferentes instrumentos

Alves, Renato de Vasconcelos 12 September 2002 (has links)
Orientador: Antonio Wilson Sallum / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T06:04:19Z (GMT). No. of bitstreams: 1 Alves_RenatodeVasconcelos_M.pdf: 677652 bytes, checksum: 0362a473db9303299846692d4a1d33ea (MD5) Previous issue date: 2002 / Resumo: O objetivo do presente estudo foi quantificar clinicamente o trauma de instrumentação produzido pela raspagem e alisamento radicular com diferentes instrumentos. Foram selecionados 1O pacientes, portadores de periodontite crônica moderada, apresentando bolsas periodontais de 3,5 a 6,5 mm em dentes anteriores superiores e/ou inferiores. Os dentes foram divididos aleatoriamente para cada um dos 3 seguintes grupos: Grupo LP - instrumentados com limas de Hirschfeld; Grupo MC - instrumentados com mini-curetas tipo Gracey (MiniFive@); Grupo CC (controle) - instrumentados com curetas tipo Gracey convencionais. Os dentes selecionados foram sondados com uma sonda eletrônica computadorizada, com o auxílio de um guia de sondagem, para, então, serem submetidos à raspagem e alisamento radicular. Imediatamente após a raspagem, os dentes foram novamente sondados. A diferença do nível de inserção clínica relativo (NIC) imediatamente antes para o NIC imediatamente após a raspagem foi considerada a medida do trauma de instrumentação. A análise intragrupo revelou diferenças estatisticamente significantes entre o NIC imediatamente antes e o NIC imediatamente após, entre os 3 diferentes grupos (1,28 :t 1,13 para o grupo LP; 0,68 :t 0,32 para o grupo MC; e 0,83 :t 0,41 para o grupo CC - p<0,05). Entretanto, a análise intergrupo revelou não haver diferenças estatisticamente significantes entre o grau de trauma de instrumentação provocado pelos diferentes instrumentos. Dentro dos limites deste estudo, conclui-se que a instrumentação radicular, independentemente do instrumento utilizado, produz um trauma de instrumentação de 0,93 mm, em média. Nenhum dos instrumentos utilizados mostrou benefício em relação ao trauma produzido no fundo da bolsa periodontal ao final da instrumentação, quando comparados entre si / Abstract: The aim of this study was to clinically quantify trauma from instrumentation produced by scaling and root planing with different instruments. T en subjects with moderate chronic periodontitis were selected. Patients should present a minimum of 5 periodontal pockets, with depths ranging from 3.5 to 6.5 mm, in anterior teeth (upper and/or lower). Qualifying teeth were randomly selected for each of the 3 groups: PF group - scaled and planed with Hirschfeld periodontal files; MC group - scaled and planed with Gracey mini-curettes MiniFiveTM); CC group (control) - scaled and planed with Gracey conventional curettes. The selected teeth were probed with a computerized electronic probe, guided with an occlusal stent, and then subjected to scaling and root planing. Immediately following instrumentation, teeth were probed again. The difference between clinical attachment level (CAL) immediately before and immediately after instrumentation was considered trauma from instrumentation. Intra-group analysis revealed statistically significant differences between CAL immediately before and immediately after in the 3 groups (1.28+/- 1.13 for PF group; 0.68 +/- 0.32 for MC group; and 0.83 +/- 0.41 for CC group - p<0.05). However, inter-group analysis did not show statistically significant differences in trauma from instrumentation caused by the different instruments. Within the limits of this study, it was concluded that root instrumentation, regardless the instrument used, causes trauma from instrumentation of 0.93 mm (mean) and none of the instruments showed any benefits regarding trauma at the bottom of periodontal pocket after periodontal instrumentation / Mestrado / Periodontia / Mestre em Clínica Odontológica

Page generated in 0.1013 seconds