• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • 5
  • 4
  • 3
  • 2
  • Tagged with
  • 38
  • 13
  • 8
  • 7
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Contribution à la mesure de bioimpédance électrique de cellules biologiques par micro-capteurs interdigités : optimisation, conception et validation de capteurs / Contribution to the measurement of electrical bioimpedance of biological cells by interdigitated micro-sensors : Optimization, design and validation of sensors

Ngo, Thanh Tuan 09 July 2015 (has links)
Cette thèse porte sur la conception et la réalisation de micros capteurs à électrodes interdigitées pour la caractérisation des milieux biologiques dans la gamme de fréquences : 100 kHz - 10 MHz. L'objectif principal de ce travail est l’optimisation géométrique de la structure d’un capteur à électrodes interdigitées afin d’élargir la plage fréquentielle de mesure en réduisant les effets de polarisation. Le premier chapitre synthétise les données fondamentales relatives au comportement électrique des tissus biologiques ainsi que leurs propriétés électriques notamment en basses fréquences. Le deuxième chapitre concerne une approche théorique pour l’optimisation du capteur pour élargir la bande de fréquence utile de mesure ; ce chapitre recommande également une nouvelle méthode pour déterminer les paramètres de la double couche à la surface en contact entre les électrodes et le milieu biologique. Dans le troisième chapitre nous proposons une modélisation tridimensionnelle du système d’électrodes chargé par un modèle du milieu biologique sous le logiciel ConventorWare®. Les résultats de simulation sont discutés. Les résultats obtenus nous permettent d’évaluer l'influence des paramètres géométriques de la structure interdigitée du capteur ainsi que les propriétés diélectriques du milieu sur l’impédance bioélectrique. Les facteurs d’influence en fonction de la fréquence sont ainsi maîtrisés lors de la conception d’u capteur interdigité destiné à la mesure de bioimpédance. Dans le quatrième chapitre, les dispositifs ainsi que la conception et la fabrication des composants développés au cours de cette thèse sont décrits. Dans le dernier chapitre, les mesures expérimentales effectuées avec de très faibles volumes de différentes solutions (solutions étalons, sang humain) par cinq micros capteurs à électrodes interdigitées. Les mesures sur les échantillons ainsi que la validation des théories d’optimisation ont été élaborées et discutées. Enfin nous avons comparé nos résultats à des valeurs publiées dans la littérature et nous avons justifié expérimentalement la théorie d’optimisation développée. / This thesis focuses on the design and realization of interdigitated sensors for the electrical characterization of the biological medium within the frequency range: 100 kHz - 10 MHz. The main objective of this thesis is to optimize the geometry of the sensor structure according to the specificities of the interdigitated electrodes structure. This optimization leads to widen the measurement frequency range by reducing the effects of polarization at low frequency. The first chapter synthesizes the basics and fundamentals relative to the electric behavior of biological tissues as well as to their electric properties. The second chapter concerns a theoretical approach for the optimization of the sensor to widen the useful frequency band of measurement; this chapter also presents a new method to determine the parameters of the double layer at the contact interface between the electrodes and the biological medium. A three-dimensional modelling of the system, the electrodes being loaded with a biological medium, is implemented using ConventorWare® software and the results discussed in the third chapter. The results obtained allow us to evaluate the influence of the geometrical parameters of the interdigitated structure of the sensor as well as the dielectric properties of the medium on the bioelectric impedance. In the fourth chapter, the devices developed during this thesis are described. The design and the manufacturing of components are presented. The last chapter deals with the experimental measurements obtained with very small volumes of the different solutions (standard solutions, human blood) using five micro sensors that we built in the laboratory. The measurements as well as the validation of the theoretical approach are discussed. Finally we have compared our results with published values in the literature and validated our experimental and theoretical approaches developed in this work.
32

Caractérisations diélectriques très large bande de films minces ferroélectriques de BaxSr(1-x)TiO3 pour des applications de reconfigurabilité de dispositifs hyperfréquences / Broadband dielectric characterization of BaxSr(1-x)TiO3 ferroelectric thin films for reconfigurability applications of microwave devices

Ghalem, Areski 10 December 2014 (has links)
Ce travail de thèse s’inscrit dans le cadre de l’intégration des films minces ferroélectriques de BaxSr(1-x)TiO3 au sein de dispositifs microondes. Dans un premier temps, les caractéristiques diélectriques des films de B0.3S0.7TiO3 déposés par pulvérisation cathodique ont été déterminées. Il a été mis en évidence l’intérêt d’une couche tampon dans le contrôle de l’orientation des films ainsi que son impact dans l’évolution des propriétés diélectriques. L’utilisation d’une structure coplanaire optimisée a été utilisée dans le but de déterminer les évolutions fréquentielles de la permittivité, des pertes ainsi que de l’accordabilité jusqu’à 67 GHz. La caractérisation du matériau a permis la réalisation et la qualification de l’élément de base dans la conception de dispositifs microondes accordables : la capacité ferroélectrique. Le phénomène d’agilité a été mis en exergue au sein de cette structure.Par la suite, une analyse complète a été menée sur un dispositif de type résonateur. Une étude analytique couplée à la réalisation de démonstrateur a permis de mettre en évidence la configuration nous permettant d’exploiter au mieux les propriétés des films de BST. / This work is dedicated to the integration of ferroelectric BaxSr(1-x)TiO3 thin films in microwave devices. Initially, the dielectric properties of B0.3S0.7TiO3 films deposited by radiofrequency magnetron sputtering were determined. It has been demonstrated the influence of a buffer layer in the control of orientation films and the impact in the evolution of dielectric properties. The realization of optimized coplanar waveguide has permit to determine the frequency evolution of permittivity, loss factor and tunability up to 67 GHz. The characterization of the dielectric properties has enabled the realization and qualification of the basic element in the design of tunable microwave devices: the ferroelectric capacitance. The agility property has been highlighted within this structure. Subsequently, a complete analysis was conducted on a resonator. An analytical study coupled with the demonstrator realization highlighted the configuration allowing us to exploit the properties of BST films.
33

Interdigitated ITO sensor for ECIS monitoring of breast cancer cells / Capteur interdigité en ITO pour le suivi par mesures d'impédance de cellules cancèreuses du sein

Martinez Santamaria, Jaime Andres 05 February 2019 (has links)
Dans la lutte contre le cancer, la médecine personnalisée est une stratégie nécessaire et très prometteuse. En effet, il est primordial de pouvoir tester l'innocuité et l'efficacité de médicaments anticancéreux sur des échantillons provenant du patient lui-même, du fait de la diversité des réponses entre patients. Le but est d'améliorer la performance des soins et d'éviter des traitements inutiles et même parfois nocifs pour le patient. Ainsi, l'exemple de la chimiothérapie illustre parfaitement cette stratégie. Le cout élevé des molécules thérapeutiques, la nocivité de ces molécules et les réponses variées des patients face à une même molécule implique le recours aux tests de ces molécules sur un échantillon provenant du patient lui-même. Il en résulte un intérêt croissant dans le développement de tests simples, robustes et peu couteux permettant l'évaluation de la chimio sensibilité de cellules biologiques issues d'une biopsie. Les problématiques liées à la mise en place de tels tests sont la quantité de cellules disponibles dans une biopsie, la diversité des molécules thérapeutiques à tester et également le choix d'une technique de détection permettant de suivre la cinétique d'action des molécules sur les cellules biologiques. L'une des réponses à la faible quantité de cellules est le développement de tests dans des environnements microfluidiques qui nécessitent donc l'intégration et la miniaturisation d'une technique de détection. La stratégie qui sera étudiée dans cette thèse est l'utilisation de l'impedancemetrie par le biais d'électrodes inter digitées d'Oxyde d'Etain et d'Indium (ITO) pour l'analyse quantitative de l'état de cellules de cancer du sein pour des applications de criblage de médicaments anticancéreux. Ce matériau présente l'avantage d'être transparent permettant ainsi des mesures d'impédance qui pourrait être couplées à des mesures optiques dans un environnement microfluidique. Dans une première partie, nous avons caractérisé et étudié des électrodes inter digitées d'or et d'ITO pour des mesures d'impédance avec des cellules cancéreuses. Cette caractérisation par spectroscopie d'impédance réalisée dans des solutions de milieu de culture en présence et absence de cellules, ont permis de démontrer que la différence de sensibilité entre ces deux matériaux provenait à la fois d'une différence de comportement résistif mais également d'une différence d'impédance interfaciale, dans les deux cas à la défaveur de l'ITO. Après ce constat, nous avons donc poursuivi l'étude afin d'évaluer les capacités de l'ITO pour des mesures de chimio sensibilité de la molécule 5-fluorouracil et également proposé une stratégie pour améliorer la sensibilité de l'ITO tout en conservant sa transparence. La stratégie développée consiste en la modification de la surface de d'électrodes d'ITO avec de l'oxyde d'iridium pour améliorer la sensibilité de l'ITO, tout en gardant sa transparence. Cette approche est intéressante pour pouvoir concevoir un dispositif transparent et facile à coupler avec un système d'observation microscopique dans un environnement microfluidique / In the fight against cancer, personalized medicine is a necessary and very promising strategy. In fact, it is essential to be able to test the safety and effectiveness of anticancer drugs on samples from the patient, due to the diversity of responses between patients. The aim is to improve the performance of health care and avoid unnecessary and sometimes harmful treatments. Thus, chemotherapy perfectly illustrates this strategy. The high cost of therapeutic molecules, the harmfulness of these molecules and the varied responses of patients involve the use of tests with chemotherapeutic molecules on samples coming from cancer patients. This results in a growing interest in the development of simple, robust and inexpensive tests for assessing the chemo sensitivity of biological cells from a biopsy. The problems related to carrying out such tests are the quantity of cells available in a biopsy, the diversity of the therapeutic molecules to be tested and also the choice of a detection technique, able to monitor the kinetics of action of the molecules on the biological cells. One solution to the small amount of cells is to carry out the tests in microfluidic environments which therefore require the integration and miniaturization of a detection technique. The strategy that will be studied in this thesis is the use of electrical impedance with interdigitated electrodes of indium tin oxide (ITO) for the quantitative analysis of the state of breast cancer cells for screening applications of anticancer drugs. This material has the advantage of being transparent allowing impedance measurements that could be coupled to optical measurements in a microfluidic environment. In the first part, we characterized and studied interdigitated electrodes of gold and ITO for impedance measurements with cancer cells. This impedance spectroscopy characterization carried out in culture medium solutions, in the presence and absence of cells, demonstrated that the difference in sensitivity between these two materials comes from a difference in resistive behavior and also from a difference in interfacial impedance, in both cases to the disadvantage of ITO. After this, we continued the study to evaluate the capabilities of ITO for chemosensitivity measurements using the molecule 5 fluorouracil and we suggested a strategy to improve the sensitivity of ITO while maintaining its transparency. The strategy developed consists of modifying the surface of ITO electrodes with iridium oxide to improve the sensitivity of the ITO, while keeping its transparency. This approach is interesting for developing a transparent device and easy to couple with a microscopic observation system in a microfluidic environment
34

The Structure Of Braid Bars: Facies Relationships of Pleistocene Braided Outwash Deposits, Paris, Ontario

Eynon, George January 1972 (has links)
<p> A large gravel pit at East Paris exposed 14m of Pleistocene braided outwash. Large scale longitudinal bars (30 - 400m long) were developed utilising irregular topographic highs (4 - 6m) of the basal gravels as Bar Cores. These bars prograded downstream by means of larce-scale cross-strata, periodically interupted by reactivation surfaces. Contemparaneous upstream addition of material took place by the migr ation of mixed sand and gravel bed-forms on the stoss-side of the bars. The gravel supply to the avalanche face of the major bars took the form of imbricated gravels which passed from the stoss-side, through the Bar Top, onto the Bar Front. Adjacent, sandy side-channels (4 -6m deep) exhibit a fining upward fill of trough cross beds, planar lamination and ripples; and interdigitated with the gravel bars alongside. </p> <p> Aggradation of the flood plain led to the extension of the Bar Top facies over the length of the bars, and then to the development of a Shallow-braided stream facies over the whole system. The latter is recognised by its smaller (less than 1m) bar forms composed of crossbedded gravel supplied by an imbricate gravel, and numerous small, sandy channel forms. </p> <p> At West Paris another large gravel pit exposed 6m of sandier, but stratigraphically equivalent deposits. Large scale side-bar accumulations (200-300m across) of gravel developed from river bank lateral accretion deposits. The downstream progradation was by lobes of cross-stratified and imbricated gravels, alternating with sand drapes of low flow stages. Sandy Side-channels (4m deep) developed between the gravel lobes and the accreting river bank. </p> <p> The concept of braid bar growth from a pre-existing form (bar core or river bank) is in contrast to the classic theory of development from a gravel lag. The differences may be due to depth relationships of the systems, which in this case may be the effect of position on the sandur surface. </p> / Thesis / Master of Science (MSc)
35

Etude du comportement thermique et électrique des cellules photovoltaïques en silicium cristallin sous concentration / Study of thermal and electrical behavior of crystalline silicon solar cells under concentration

Couderc, Romain 29 June 2015 (has links)
Le silicium est très utilisé dans la production de cellules photovoltaïques mais très peu pour les applications sous concentration. Il possède pourtant un fort potentiel sous concentration grâce à son faible coût et la maturité de sa filière industrielle. De plus, il est possible d'avoir recours à la cogénération pour augmenter fortement les rendements énergétiques du système. La concentration et la cogénération impliquent un fonctionnement de la cellule à une température plus élevée que les conditions standards de test des cellules photovoltaïques. Cela engendre le besoin de connaître le comportement thermique et électrique de la cellule en fonction de sa température de fonctionnement. La variation de celle-ci, en conditions réelles, est pourtant souvent ignorée. Pour remédier à cette lacune, nous présentons un modèle électro-thermo-radiatif pour les cellules photovoltaïques en silicium cristallin. Il réalise le couplage de l'ensemble des phénomènes physiques prenant place dans une cellule photovoltaïque sous éclairement. Grâce à de nombreuses analyses effectuées dans le cadre des travaux de cette thèse, l'importance du comportement thermique d'une cellule photovoltaïque pour sa conception est mise en évidence. Entre autres, la variation de la température de la cellule avec sa tension que nous avons confirmé expérimentalement grâce à des mesures de température différentes de 2°C entre le Mpp et le Voc. Un des paramètres majeurs influençant le comportement électrique et thermique d’une cellule photovoltaïque en silicium est la densité de porteurs de charge intrinsèque du silicium, ni. Le développement du modèle électro-thermo-radiatif nous a amené à proposer une nouvelle expression semi-empirique de sa variation en fonction de la température. En complément de ces avancées théoriques, la réalisation de cellules photovoltaïques à contacts arrière interdigités implantées ioniquement (3IBC) a été menée. Nous avons diminué le nombre d'étapes nécessaires à sa réalisation et amélioré sa métallisation grâce à un empilement Si/Ti/Ag permettant d'espérer un gain absolu pour le Jsc de 0.72 mA.cm-2. Un rendement de 14.6% a été obtenu sous 1 soleil avec une cellule 3IBC dont la résistance série est de seulement 0.4 Ω.cm2 ce qui confirme le potentiel des cellules 3IBC pour la concentration linéaire. / Silicon is largely used to produce solar cells but not for applications under concentration. Nevertheless, it has a great potential under concentration thanks to its low cost and the maturity of its industry. Moreover, it is possible to cogenerate electric and thermal power in order to increase the energy output. Cogeneration and concentration imply a higher operating temperature than under standard conditions. Thus, it is interesting to understand the thermal and électrical behavior of the cell as a functiton of its temperature. However the variation of the operating temperature is often ignored. In order to change this, we propose an electro-thermo-radiative model for crystalline silicon solar cells. It couples all phenomenon taking place in an illuminated solar cell. Thanks to this thesis, the importance of the thermal behavior is outlined. For example, the temperature variation as a function of the voltage that we confirmed experimentaly thanks to mesures of the cell temperature at Mpp and at Voc. One of the most important parameters in a silicon solar cell is the intrinsic carrier density, ni. The work on the electro-thermo-radiative model led us to propose a new semi-empirical temperature variation of ni. In addition to these theoretical analysis, we realized ionically implanted interdigitated back contacts solar cells (3IBC). Thanks to this work fewer process steps are needed and the improved metallization (Si/Ti/Ag) possibly lead an absolute Jsc gain of 0.72 mA.cm-2. The efficiency of the best 3IBC cell is 14.6% under 1 sun illumination with a particularly low series resistance (0.4 Ω.cm2) which confirm the potential of such cells for linear concentration.
36

The synthesis of oligothiophene functionalized dimethyldihydropyrenes and their electrical and photochromic properties

Robinson, Stephen Garfield 09 April 2008 (has links)
The synthesis of benzo[e]dimethyldihydropyrene (BDHP) photoswitches with ter-27, quarter-36, and quinque-28 thiophene oligomers attached on the same side of the switch was achieved using Stille coupling reactions. BDHP photoswitches with bi-75, ter-76 and quinque-77 thiophene oligomers attached directly to the switch on one side, and via a carbonyl spacer on the opposite side of the switch were also synthesized. Dimethyldihydropyrene (DHP) photoswitches with a naphthoyl functional group in the 2 position were synthesized using a Friedel Crafts reaction, and ter-96, quinque-97 and septi-98 thiophene oligomers were attached on opposite sides of the switch using Stille coupling reactions. All compounds were characterized by NMR, IR UV-vis spectroscopy and mass spectrometry. The relative rates of the photo-opening reactions under excess light conditions and the UV closing reactions versus BDHP were measured. Improvements in the photo-opening properties of the oligothiophene functionalized switches compared to BDHP were observed. The most dramatic photo-opening improvement was found for the quinquethienyl substituted DHP switch 97 which photo-opened when irradiated with visible light over 100 times faster than BDHP. UV closing rates were virtually the same as that of BDHP. However the addition of oligothiophenes led to an increase in the thermal closing reaction rates. Compounds with the naphthoyl functional group in the 2 position of DHP were found to have dramatically increased thermal closing rates. The electrochemical properties of oligothiophene functionalized BDHP and naphthoyl functionalized DHP switches in the closed form were studied by cyclic voltammetry and spectroelectrochemistry. During the oxidation cycle, a closing reaction from the cyclophanediene (CPD) form to the DHP form of the switches occurred which prevented the study of the electrochemical properties of the switches in the open form. Conductivity testing was performed on the quinquethienyl substituted DHP switch 97 using a gold interdigitated micro electrode array. The conductivity of undoped 97 was greater in the closed DHP isomer than in the open CPD isomer. Irradiation with red or blue light allowed for repetitive switching between the more highly conducting closed form and the less conducting open form. When electrochemically doped, 97 showed improved conductivity over the undoped form but only the conductivity of the closed doped form could be measured due to electrochemically induced closing.
37

An Investigation of Low Temperature Direct Propane Fuel Cells

Parackal, Bhavana January 2017 (has links)
This research is directed toward the investigation of a low temperature direct propane fuel cell (DPFC). Modeling included a parametric study of a direct propane fuel cell using computational fluid dynamics (CFD), specifically FreeFem++ software. Polarization curves predicted by the CFD model were used to understand fuel cell performance. The predictions obtained from the computational fluid dynamics mathematical model for the fuel cell were compared with experimental results. The computational work identified some critical parameters (exchange current density, pressure, temperature) for improving the overall performance of the fuel cell. The model predictions clearly highlighted the role of catalysts in significantly enhancing the overall performance of a DPFC. Experiments were performed using commercial Nafion-Pt based membrane electrode assemblies (MEAs) to obtain a basis for comparison. It is the first report in the literature that a Pt-Ru (Platinum-Ruthenium) MEA was used in the investigation of a DPFC. Also, it was the first study that fed liquid water continuously to a DPFC by using interdigitated flow field (IDFF) at the anode to humidify the dry propane feed gas. During the experiments oscillations were observed at very low current densities i.e. in nA/cm2, which is a rare case and not reported in the literature to date. This observation has raised serious concerns about the existence of absolute open-circuit cell potential difference for a DPFC. The cycling behaviour observed with DPFC indicated the presence of a continuous degradation-regeneration process of the catalyst surface near open-circuit potential. The experimental work further evaluated the performance of fuel cell by measurement of polarization curves.
38

Intégration d’une méthode d’actuation électrocinétique sur biocapteur plasmonique / Integrating an electrokinetic actuation method on a plasmonic biosensor

Avenas, Quentin 20 December 2018 (has links)
Cette thèse porte sur le développement d’un capteur plasmonique intégrant une fonction d’actuation des objets visés. L’objectif est de passer outre la limite de diffusion rencontrée à basse concentration en piégeant les particules sur la surface de détection. La stratégie adoptée est de structurer le film d’or servant à la détection de manière à pouvoir l’utiliser pour mettre en mouvement le fluide et les molécules par le biais de champs électriques. Le transfert de masse est réalisé par diélectrophorèse et électroosmose, deux effets électrocinétiques mis en oeuvre par des électrodes servant à la fois d’actuateur et de capteur plasmonique. Un état de l’art exhaustif et des simulations multiphysiques ont permis de concevoir un prototype de capteur intégré constitué d’électrodes interdigitées en or permettant la détection plasmonique. Le dispositif proposé a été obtenu par microfabrication en salle blanche puis caractérisé avant l’étude de ses performances. Une première phase de tests sur un système modèle, des billes de polystyrène dans de l’eau, a permis d’apporter la preuve de concept du fonctionnement du capteur, qui est effectivement capable de piéger rapidement les objets visés à sa surface afin de les détecter. Les mécanismes de transfert de masse ont été expliqués et la preuve de l’amélioration de la limite de détection par un facteur supérieur à 100 a été apportée. Dans un second temps, les performances du capteur appliqué à des objets biologiques ont été évaluées. Celui-ci piège efficacement des levures et des protéines, mais aucune amélioration n’a été observée dans le cas de la détection spécifique de l’hybridation entre deux brins d’acide désoxyribonucléique (ADN). Les causes de ce résultat ont été discutées et comprises et deux solutions différentes ont été explorées : l’adaptation de la fréquence d’opération et l’optimisation de la géométrie des électrodes. Ainsi, cette étude a permis de souligner la problématique de la mise en oeuvre d’effets électrocinétiques dans des milieux biologiques et de réfléchir aux pistes pertinentes pour sa résolution. / This thesis focuses on the development of an integrated plasmonic sensor capable to perform mass transport on targeted objects. The goal is to overcome the diffusion limit by trapping particules directly on the sensing surface. The adopted strategy was to structure the gold layer used for plasmonic detection in order to use the sofabricated structures to set the fluid and the molecules in motion by applying electric fields in the fluid. The mass transfer is realized through dielectrophoresis and electroosmosis, those two electrokinetic effects being operated by electrodes acting as sensor and actuator at the same time. An exhaustive state of the art as well as multiphysical simulations allowed us for designing a prototype for an integrated sensor consisting in gold interdigitated electrodes enabling plasmoninc sensing. The proposed device was obtained through microfabrication in clean room facilities and was characterized before the study of its performances. A first sequence of tests on a model system – polystyrene microbeads in water – brought the proof of concept we needed to validate the correct operation of the sensor, which is indeed capable of quickly trapping targeted objects on its surface and detecting them. The mass transfer mechanisms were explained and we showed the enhancement of the limit of detection by a factor greater than 100. In a second phase, performances of the sensor applied to biological objects were evaluated. It can effectively trap yeasts and proteins but no enhancement has been observed while detecting DNA hybridization events. Causes for this result were discussed and understood and two different solutions were explored: the adaptation of the operating frequency and the optimization of the electrodes geometry. Thus, this study highlighted the problematic of operating electrokinetic effects in biological media and suggested relevant leads towards its resolution.

Page generated in 0.0666 seconds