• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 452
  • 450
  • 208
  • 110
  • 28
  • 25
  • 23
  • 15
  • 11
  • 10
  • 8
  • 8
  • 8
  • 6
  • 3
  • Tagged with
  • 1477
  • 127
  • 115
  • 70
  • 62
  • 58
  • 53
  • 50
  • 49
  • 48
  • 47
  • 47
  • 47
  • 46
  • 46
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Vertical and Horizontal Intra¡VIndustry Trade between Taiwan and China

Huang, Yong-Che 03 August 2009 (has links)
International trade plays an important role in Taiwan economic development. In recent years, under the globalization and regionalization tendencies, Taiwan faced huge challenges. The international relationship between Taiwan and China had been improved a lot. The bilateral trade between Taiwan and China is the getting more and more important. This paper measures intra- industry trade (IIT) indicators between Taiwan and China from 2000 to 2008 to analyze the bilateral trade structure between Taiwan and China. I analyze further how the horizontal or the vertical IIT is orientated by relative unit va lue of imports and exports to identify differences in the quality of products traded between Taiwan and China. We also investigate market size, demand similarity, and trade imbalance to be determinants of the IIT structure. Other influenc ing factors include foreign direct Investment and barriers to trade. The empirical results show that, in general, the number of industries that engage in IIT and the overall level of IIT have been increased. We also find that the majority of IIT industries belongs to vertical IIT (VIIT), and the pattern of expansion is dominated by VIIT as well. For most industries, Chinese products imported from Taiwan are generally of a higher quality than the products Taiwanese products imported from China. And furthermore the policy implications discussions on the Government¡¦s promoting domestic and cross strait economy measures are conducted and derived.
2

Avaliação crítica do uso do DIU por mulheres atendidas no ambulatório de anticoncepção do serviço de reprodução humana, do departamento de tocoginecologia, da maternidade do hospital de clínicas da Universidade Federal do Paraná

Boza, Vera Maria Araújo Garcia e January 2002 (has links)
Orientadora : Claudete Reggiani Mello / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Ciências da Saúde, Programa de Pós-Graduação em Tocoginecologia. Defesa: Curitiba, 23/08/2002 / Sem resumo e abstract
3

Estabelecimento do padrão ecografico transvaginal da posição do DIU e avaliação da sua influencia sobre o desempenho deste anticoncepcional

Faundes, Daniel 29 August 1996 (has links)
Orientadores: Luis Bahamondes, Anibal Faundes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-11-07T16:46:44Z (GMT). No. of bitstreams: 1 Faundes_Daniel_D.pdf: 3215079 bytes, checksum: a56dff978a375c999d92766883b81cf7 (MD5) Previous issue date: 1996 / Resumo: Objetivos: Definir a posição normal do dispositivo intra-uterino (DIU) dentro da cavidade endometrial, e comparar essa posição em mulheres sem e com queixas. Sujeitos e métodos: Foram realizadas ecografias vaginais em 245 mulheres sem queixas e 236 com queixas, que estavam usando o TCu 200 ou TCu 380A, por seis meses ou mais. Em cada uma das mulheres foram medidas as distâncias DIU endométrio, DIU-miométrio e DIU-fundo. Resultados: A distribuição dos valores individuais para cada uma dessas três distâncias em usuárias sem queixas foi comparada à distribuição dos valores de mulheres com queixa de sangramento e/ou dor. Encontrou-se uma grande variabilidade nos valores das três distâncias entre as usuárias sem queixas. Os percentis90 ficaram em 7, 11 e 27mm para DIU-endométrio, DI~-miométrio e DIU-fundo, respectivamente. As distribuições de medidas, das três distâncias, em usuárias com queixas foram quase iguais às de mulheres sem queixas. Utilizando-se, como limite de normalidade, a distância DIU-fundo de ,'20 e 25mm encontrou-se, respectivamente, 77 e 43% de falso positivo para "posicionamento anormal" do DIU. A distância DIU-endométrio foi utilizada como padrão ouro. Obtiveram-se resultados semelhantes quando a distância DIU-miométrio foi usada como padrão ouro. Conclusões: Os percentis 90 das distâncias DIU-endométrio, DIU miométrio e DIU-fundo foram 7, 11 e 27mm, respectivamente, nas usuárias sem queixas. Não houve diferenças na posição do DIU em usuárias sem e com queixas. A distância DIU-fundo foi a menos adequada para avaliar a posição do dispositivo / Abstract: Objectives: To define the normal situation of the intrauterine device (lUD) in the endometrial cavity and to compare its position among women without and with complaints. Subjects and methods: vaginal ultrasound was carried out among women using a TCu 200 or a TCu 380A for at least six months, 245 women without complaints and 236 with. The distance IUD-endometrium, IUD-myometrium and IUD-fundus was measured in each woman. Results: The distribution of the individual values of each of the three distances in users without complaints was compared with that of the women complaining of bleeding and/or pain. Great variability was found in the three distances in users without complaints, with percentile 90 in 7, 11 and 27mm for IUD-endometrium, IUD-myometrium and IUD fundus, respectively. The distribution of the measurements for the three distances, among . women with complaints was almost the same as that of subjects without. Using a measurement of IUD-fundus of 20 or 25mm as the limit for raormality and the distance IUD endometrium as gold standard, 77 and 43% of false positives were found for "bad position" of the IUD. Similar results were obtained when the distance IUD-myometrium was used as gold standard. Conclusions: The 90th percentile of the distance IUD-endometrium, IUD-myometrium and IUD-fundus was 7, 11 and 27mm, repectively, among users without complains. There was no difference in the position of the IUD among users without and with complaints. The IUD-fundus distance was the least adequate to evaluate the position of the device / Doutorado / Tocoginecologia / Doutor em Ciências Médicas
4

The nature and the determinants of horizontal and vertical intra-industry trade a case of Thailand /

Sarawan Angklomkliew. January 1900 (has links)
Thesis (master's)--Thammasat University, May, 2005. / Includes bibliographical references (leaves 132-137).
5

Efeitos agudos do exercício resistido na pressão intra-ocular em homens ativos, jovens e saudáveis / Variações agudas da pressão intra-ocular durante o exercício resistido dinâmico em homens, jovens, ativos e saudáveis

Vieira, Geraldo Magela 03 June 2008 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Ciências da Saúde, 2008. / Submitted by Larissa Ferreira dos Angelos (ferreirangelos@gmail.com) on 2010-03-09T02:48:00Z No. of bitstreams: 1 2008_GeraldoMagelaVieira.pdf: 698788 bytes, checksum: 7fbcacb7f63e662f9de54bbfb8966c77 (MD5) / Approved for entry into archive by Daniel Ribeiro(daniel@bce.unb.br) on 2010-03-10T01:12:38Z (GMT) No. of bitstreams: 1 2008_GeraldoMagelaVieira.pdf: 698788 bytes, checksum: 7fbcacb7f63e662f9de54bbfb8966c77 (MD5) / Made available in DSpace on 2010-03-10T01:12:38Z (GMT). No. of bitstreams: 1 2008_GeraldoMagelaVieira.pdf: 698788 bytes, checksum: 7fbcacb7f63e662f9de54bbfb8966c77 (MD5) Previous issue date: 2008-06-03 / OBJETIVO: Verificar os do exercício resistido de supino reto horizontal sobre a pressão intra-ocular (PIO) executado com e sem bloqueio da respiração. MÉTODOS: Sessenta olhos de 30 indivíduos (todos homens) foram envolvidos. Os indivíduos executaram 4 repetições do exercício de supino, de dois modos diferentes. No modo I, eles deveriam prender a respiração durante a última repetição. No modo dois, eles deveriam soltar o ar normalmente durante a última repetição. A tonometria eletrônica (Tono-pen XL) foi utilizada para as medições da PIO. O olho direito foi usado para testar o modo I, e o esquerdo para o modo II. A PIO foi medida durante a quarta e última repetição, enquanto o indivíduo sustentava a barra de pesos na posição superior. RESULTADOS: A PIO média durante o exercício no modo I sofreu um aumento de 4,3 (SD 4,2) mmHg (p< 0.001, teste t pareado; variando de – 3,6 a + 17,7 mmHg). No modo II, a PIO média sofreu um aumento de 2,2 (SD 3,0) mmHg (p< 0.001, teste ANOVA, variando de -6,0 a + 8,7 mmHg). A PIO aumentou em 90% dos olhos submetidos ao exercício modo I e em 62 % no modo II. Um aumento na PIO > 5,0 mmHg foi observado em 9 olhos (30%) no modo I, e em 6 olhos no modo II (21%). A PIO em dois indivíduos que executaram o exercício modo I teve um aumento marcante (> 10.0 mmHg). CONCLUSÃO: A PIO aumenta de modo significativo durante o levantamento de peso no exercício de supino. Prender a respiração durante o exercício leva a um aumento extra da PIO. Os resultados podem são clinicamente significantes. _____________________________________________________________________________________ ABSTRACT / AIM: To evaluate the effect of resisted exercise bench press on intraocular pressure (IOP). METHODS: Sixty eyes of 30 normal, male subjects were enrolled. Subjects performed four repetitions of bench press exercise in two different ways: in mode I, breathing was held in the last repetition, and in mode II, subjects exhaled normally in the last repetition. An electronic tonometer (Ton-pen XL) was used for IOP measurements. The right eye was used for testing in mode I and the left eye for testing in mode II. IOP was measured during the fourth repetition in both modes while the subject sustained the exercise. RESULTS: mean IOP during exercise in mode I increased by 4.3 (SD 4.2) mmHg (p<0.001, ANOVA test; range -3.6 to +17.7 mmHg). In mode II, mean IOP increased by 2.2 (SD 3.0) mmHg (p< 0.001, paired t test; range -6.0 to + 8.7 mmHg). IOP increased in 90% of eyes submitted to mode I, and in 60% of eyes in mode II. An increase on IOP > 5.0 was observed in 9 eyes (30%) in mode I, and in six eyes (21%) in mode II. IOP in two eyes from subjects who performed exercise mode I was markedly increased (> 10.0 mmHg). CONCLUSION: IOP increases significantly during weight lifting in a bench press exercise. Holding the breath during the exercise leads to a further increase on IOP. The results are clinically significant.
6

Comparação da eficácia das lentes intraoculares restor esférica - SN60D3 - e restor asférica - SN6AD3

Porfírio Neto Junior, Francisco January 2009 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, 2009. / Submitted by Allan Wanick Motta (allan_wanick@hotmail.com) on 2010-04-01T12:24:19Z No. of bitstreams: 1 2009_FranciscoPNJunior.pdf: 873921 bytes, checksum: b8c21f11bac2583450a9d6fe651959a3 (MD5) / Approved for entry into archive by Lucila Saraiva(lucilasaraiva1@gmail.com) on 2010-05-21T16:26:57Z (GMT) No. of bitstreams: 1 2009_FranciscoPNJunior.pdf: 873921 bytes, checksum: b8c21f11bac2583450a9d6fe651959a3 (MD5) / Made available in DSpace on 2010-05-21T16:26:57Z (GMT). No. of bitstreams: 1 2009_FranciscoPNJunior.pdf: 873921 bytes, checksum: b8c21f11bac2583450a9d6fe651959a3 (MD5) Previous issue date: 2009 / Objetivos: comparar a eficácia visual para longe, perto e intermediário com e sem correção das lentes intraoculares multifocais difrativas apodizadas Restor Asférica - SN6AD3 - e Restor Esférica - SN60D3 -, além de avaliar a performance visual destas lentes por meio do exame de aberrometria. Metodologia Científica: 68 olhos foram submetidos à facoemulsificação com implante de lente intraocular multifocal Restor Asférica e Restor Esférica. No 3 mês de pós-operatório, foram avaliadas, em condições fotópicas (85 cd/m2), as acuidades visuais, com e sem correção, para longe (6 metros), perto (33 cm) e intermediário (60 cm). Todos os pacientes foram submetidos ao exame de aberrometria e comparados os resultados por meio de testes estatísticos paramétricos e não-paramétricos (teste de Kruskal-Wallis e teste t-Student). Resultados: Os pacientes analisados (72,23% femininos) tinham idade média de 70 anos, variando de 58 a 79 anos. A dioptria das lentes intraoculares multifocais implantadas nos pacientes deste estudo apresentouse dentro dos valores mais comuns, onde 83,8% dos pacientes usaram lentes intraoculares com medidas entre 20 e 24 dioptrias, com uma média de 21,4 e com desvio padrão de 2,1. A medida da acuidade visual média dos pacientes com lente Restor Asférica foi pior na distância intermediária, onde a Acuidade Visual foi, aproximadamente, de 20/32 (J4) com e sem correção. Para perto e longe, a AV das lentes asféricas ficou em torno de 20/20 com correção. Os pacientes com lente Restor Esférica também apresentaram acuidade visual, em média, de 20/20, para perto e para longe, com correção. Na distância intermediária a AV foi, em média, de 20/30 (J3) sem correção e 20/32 com correção. Nessas lentes, a acuidade visual para longe, sem correção, alcançou a média de 20/25. Não houve diferenças estatisticamente significativas entre as lentes esféricas e asféricas nas acuidades visuais para perto sem correção (p=0,345), para perto com correção (p=0,903), para intermediário sem correção (p=0,798), para intermediário com correção (p=0,743) e para longe com correção (p=0,133). A lente Restor Asférica apresentou melhor acuidade visual para longe sem correção (p=0,000). Não existiu diferença estatística entre as medidas do equivalente esférico (p=0,965) e das aberrações do olho (aberração total 5mm - p=0,273) (aberração total 6mm p=0,742) (HOA 5mm p=0,556) (HOA 6mm p=0,339) (aberração esférica 6mm p=0,360) entre a lente asférica e esférica. Conclusões: Não foram observadas diferenças estatisticamente significativas entre as lentes multifocais Restor Asférica e Restor Esférica nas visões de perto e intermediário com e sem correção. A Restor Asférica alcançou melhor acuidade visual para longe, sem correção, do que a Restor Esférica. Quando o erro refracional foi corrigido, a acuidade visual para longe das lentes se aproximou e deixou de ter significância estatística, além da inexistência de diferença entre as medidas do equivalente esférico e das aberrações do olho entre a lente asférica e esférica. _______________________________________________________________________________________ ABSTRACT / PURPOSE: To compare distance, intermediate and near visual acuity (VA) ,uncorrected and best corrected, and ocular aberrations in patients who had multifocal aspherical and spherical apodized diffractive intraocular lens (IOL) implantation (Restor, Alcon). METHODS: The best corrected visual acuity (BCVA), uncorrected visual acuity (UCVA), distance corrected near visual acuity (DCNVA), uncorrected near visual acuity (UCNVA), uncorrected intermediate visual acuity (UCIVA), distance corrected intermediate visual acuity (DCIVA) and ocular aberrations were measured in 68 eyes who had multifocal aspherical and spherical apodized diffractive intraocular lens (IOL) implantation (Restor, Alcon). Ocular aberrations with a 5.0 mm and 6.0 mm pupil were measured with a Hartmann-Shack aberrometer. All patients were followed for 3 months. RESULTS: The mean age of the 25 women and 9 men was 70 years ( range of 58 the 79 years). There were no statistically significant differences between eyes in postoperative uncorrected and best corrected near and intermediate visual acuities after a follow-up of 3 months. The dioptry of the implanted multifocal intraocular lenses was presented between the most common values. 83.8% of the patients had implanted intraocular lens between 20 and 24 dioptries (mean 21,5 D 2,0 D). The mean best corrected visual acuity (BCVA), distance corrected near visual acuity (DCNVA), uncorrected near visual acuity (UCNVA) were 20/20 in aspherical group. In this group, uncorrected and best corrected intermediate visual acuity (UCIVA) were worst (mean 20/32- J4 ). In the spherical group, the mean best corrected visual acuity (BCVA) and distance corrected near visual acuity (DCNVA) were 20/20. The mean uncorrected intermediate visual acuity (UCIVA) was 20/30 and the mean best distance corrected intermediate visual acuity (DCIVA) was 20/32. In spherical group, the mean uncorrected visual acuity (UCVA) was 20/25. There were no statistically significant differences between the groups in best corrected visual acuity (BCVA) (p=0,133), distance corrected near visual acuity (DCNVA) (p=0,903), uncorrected near visual acuity (UCNVA) (p=0,345), uncorrected intermediate visual acuity (UCIVA) (p=0,798), distance corrected intermediate visual acuity (DCIVA) (p=0,743) . The uncorrected visual acuity (UCVA) was better in patients with an AcrySof ReSTOR Aspherical SN6AD3 (p=0,000).There were no statistically significant differences in spherical equivalent (p=0,965), total aberration with 5 mm pupil diameter (p=0,273), total aberration with 6 mm pupil diameter (p=0,742), high-order aberration(HOA) with 5 mm pupil diameter (p=0,556), high-order aberration(HOA) with 6 mm pupil diameter (p=0,339) and spherical aberration (p=0,360) between the groups. CONCLUSIONS: There were no statistically significant differences between eyes in postoperative best corrected visual acuity (BCVA), distance corrected near visual acuity (DCNVA), uncorrected near visual acuity (UCNVA), uncorrected intermediate visual acuity (UCIVA), distance corrected intermediate visual acuity (DCIVA) and ocular aberrations. The uncorrected visual acuity (UCVA) was better in patients with an AcrySof ReSTOR Aspherical SN6AD3.
7

Avaliação clinica do uso do dispositivo intra-uterino T-Cu 200B em adolescentes

Ribeiro, Gizelda Nogueira de Oliveira, 1943- 22 July 2018 (has links)
Orientadores: Abraham Juan Antonio Diaz Moraguez, Luis Bahamondes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-07-22T23:47:34Z (GMT). No. of bitstreams: 1 Ribeiro_GizeldaNogueiradeOliveira_D.pdf: 1446840 bytes, checksum: 3b0c4ab8a4d34e8715975f3e8c0f5b0e (MD5) Previous issue date: 1997 / Resumo: O objetivo do presente estudo foi avaliar o desempenho do OIU T Cu 200B em mulheres menores de 20 anos de idade que tinham tido pelo menos um filho, comparado com o desempenho em mulheres com dez anos a mais de idade. O grupo de estudo foi constituído por 1.248 mulheres que receberam um DI U T -Cu 200B e que tinham menos de 20 anos no momento da inserção. Para formar o grupo-controle, cada mulher do grupo de estudo foi comparada a outra mulher com dez anos a mais de idade e com a mesma paridade. Ambos os grupos foram acompanhados por quatro anos depois da inserção. O desempenho foi avaliado pelo método de tabela de vida e as diferenças entre os grupos foram testadas pelo método de log-ranl<. Gravidez, expulsão e extração por dor e/ou hemorragia foram significativamente mais freqüentes no grupo de mulheres mais jovens e a taxa de continuação foi mais baixa no mesmo grupo. As taxas de extração por infecção foram baixas em ambos os grupos (taxa acumulada a quatro anos de 2/100 mulheres). A principal conclusão foi que as usuárias do OIU T-Cu 200B com menos de 20 anos tiveram taxas de fracasso maiores e mais expulsões e extrações que as mulheres com dez anos a mais de idade. Entretanto, a taxa de falha com DIU nas mulheres mais jovens foi similar ou menor que a observada com outros métodos reversíveis em adolescentes. A taxa de continuação também foi mais alta no grupo de estudo que a habitualmente observada em adolescentes com outros métodos. Concluiu-se que o DIU T-Cu 2008 não deve ser contra-indicado em mulheres com menos de 20 anos que já tiveram pelo menos um filho, desde que o processo de seleção, a técnica de inserção e o acompanhamento sejam adequados / Abstract: The objective of the study was to evaluate the clinical performance of the T-Cu 2008 IUD in women under 20 years old, having had at least one child, compared to women ten years older. The study group was constituted by 1.248 women who received a T -Cu 2008 and had less than 20 years old at insertion. To constitute the control group every woman of the study group was paired with a woman 10 years older at insertion and having the same parity. 80th groups were followed for four years afie r the insertion. Performance was evaluated by life table analysis and the differences between the groups were tested by the log-rank method. Pregnancy, expulsion, ánd removal for bleeding and or pain were significantly higher in the group of young women and continuation rate was lower in the same group. Rates of removal for infection were low in both groups (cumulative rate of 2% at four years). The main conclusion was that T Cu 2008 IUD users under 20 years old hàd higher failure rate and more expulsions and removals than women ten years older. However, failure rate with IUD in the group of women under 20 years, was similar or better than the rates observed with other reversible methods in adolescents. Continuation rate in the study group was also higher than the one usually observed in adolescents with other methods. Therefore we concluded that the Copper IUD should not be contraindicated in women under 20 years old who have had at least one child, provided a good selection procedure is used, the insertion technique is appropriate, and adequate follow-up is available / Doutorado / Tocoginecologia / Doutor em Medicina
8

Administração continua e prolongada de Levonorgestrel, por via intra-uterina : efeito sobre a fisiologia reprodutiva e avaliação clinica como anticoncepcional

Diaz Moraguez, Abraham Juan Antonio, 1941- 28 June 1989 (has links)
Orientador: Anibal Faundes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-07-14T00:17:05Z (GMT). No. of bitstreams: 1 DiazMoraguez_AbrahamJuanAntonio_D.pdf: 2040564 bytes, checksum: b43d813f9c2c96db331649ec98cf3895 (MD5) Previous issue date: 1989 / Resumo: Estudaram-se os efeitos da administração de levonorgestrel (L-Ng) por via intra-uterlna sobre o sistema reprodutor feminino e seu efeito clínico como anticoncepcional. Para a administração utilizaram-se DIUs que liberavam 20 ou 30 mcg de L-Ng por dia por um período de até sete anos. Na avaliação clínica, o grupo controle recebeu um T-Cu 380Ag, reconhecidamente eficaz. Os resultados mostraram que a via intra-uterina é eficiente para conseguir níveis sanguíneos estáveis de L-Ng e que a concentração do hormônio não é maior no ovário que na circulação geral. O efeito sobre o ovário é a anovulação em uma alta porcentagem, nos primeiros meses, depois persiste uma interferência na fase lútea. Sobre o endométrio há um claro efeito supressor de longa duração e há uma profunda alteração do muco cervical que deve ser um dos principais fatores do seu efeito anticoncepcional ¿Observação: O resumo, na íntegra poderá ser visualizado no texto completo da tese digital. / Abstract: The effects of the intrauterine administration of levonorgestrel (L-Ng) upon the femaIe reproductive system and its performance as a contraceptive method were studied. Levonorgestrel was reIeased from intrauterine devices (IUD) releasing 20 or 30 mcg/day for up to even years. The clinic study was a comparative study with the T-Cu 380Ag. The results showed that this approach is efficient to obtain stable serum levels and that the concentration of L-Ng is not greater in the ovary than in peripheric blood. The effect in the ovary was mainly inhibition of ovulation during the first year, persisting an effect on luteal phase thereafter. The endometrium was uniformly suppressed during alI the period of use. Sperm transport in cervical mucus was greatly affected. This effect should constitute one of the main factors of its mechanism of action as contraceptive. The clinic study showed that this method is highly effective with continuation rate comparable to the T-Cu 380Ag. Its main side effect is the menstrual disturbance ...Note: The complete abstract is available with the full electronic digital thesis or dissertations. / Doutorado / Doutor em Ciências Médicas
9

Estudos dos fatores que influenciam o desempenho clinico do DIU TCU-200B

Bueno, Jose Geraldo Romanello 14 July 2018 (has links)
Orientadores: João Luiz Pinto e Silva, Abrahan Juan Diaz Moraguez / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-07-14T00:17:18Z (GMT). No. of bitstreams: 1 Bueno_JoseGeraldoRomanello_M.pdf: 1350044 bytes, checksum: 7c153cd509caab42db87e88f1daaa8ff (MD5) Previous issue date: 1989 / Resumo: Foram estudadas 2.318 usuárias de DIU TCu-200B no Ambulatório de Planejamento Familiar do Departamento de Tocoginecologia da UNICAMP, entre Janeiro de 1979 a Dezembro de 1983, com a finalidade de conhecer o desempenho clínico deste método anticoncepcional. Para tanto foram analisados um conjunto de variáveis suspeitas de influenciar o desempenho clinico do dispositivo: idade; paridade; antecedente de cesáreas, abortos e tipo de método anticoncepcional anterior e número de cesáreas e abortos. Após análise estatística apropriada, concluiu-se que somente a idade e o número de cesáreas anteriores influenciaram o desempenho clínico do DIU TCu-200B, ou seja, há uma relação direta entre a taxa de continuidade e a idade da paciente e inversa quanto ao número de cesáreas. Demonstrou-se assim que, para se obter um máximo desempenho deste método anticoncepcional, o dispositivo deve ser inserido preferencialmente em pacientes com mais de 25 anos de idade e sem o antecedente de cesárea. A taxa acumulada de gravidez até o quinto ano de uso foi de 5,7%, sendo considerada uma das mais baixas para este tipo de dispositivo. As causas de abandono do método por gravidez e desejo de nova gestação mostraram-se estatisticamente significantes quando se avaliou a idade e o número de cesáreas. Quanto às causas de abandono do método por expulsão e sangramento, os resultados mostraram-se significantes somente quando se analisou o número de cesáreas, resultados estes, únicos e singulares para este tipo de dispositivo. / Abstract: Two thousand three hundred and sixteen patients with Cooper T 200B (TCu-200B) intra-uterine device (IUD) were studied between january 1979 and december 1983, with the purpose of knowing the clinical performance of this contraception method. For such, some variables suspected of influencing the IUD clinical performance were analysed: age; parity; history of previous Cesaran section (C-section), abortions and contraceptive method; number of C-sections and abortions. After appropriate statistical analysis, one concludes that only age and number of previous C-sections have influence on the clinical performance of IUD TCu-200B, in other words, there is a straight relationship between the continuation rate and patient age but oppositive for number of C-sections. In order to obtain the maximum performance, the IUD should be inserted preferably in patients. more than 25 years old and with no history of previous C-sections. The acummulated pregnancy rate for the fifth year of method usage was 5.7%, considered to be very low for the IUD TCu-200B. The causes for abandoning the method due to pregnancy and desire of a new gestation, proved to be statistically significant for age; and, causes like pregnancy, expulsion and vaginal bleeding, statistically significant for C-section numbers / Mestrado / Mestre em Ciências Médicas
10

Création de connaissances et coordination : étude des pratiques dans cinq équipes-projets / Knowing as practice and practices of coordination

Weppe, Xavier 03 December 2009 (has links)
Le management des connaissances est présenté aujourd’hui comme un enjeu majeur du fonctionnement des organisations. Il permettrait un développement des capacités d’innovation de la firme et participerait au développement de son avantage concurrentiel. Bien que la thématique du management des connaissances ait été fortement explorée ces dernières années, certaines questions restent ouvertes. L’une d’entre elles porte sur la relation entre la création de connaissances et le principe d’organisation (« organizing »). En effet, une très grande majorité des approches actuelles en Knowledge Management s’intéresse principalement aux systèmes de gestion des connaissances et aux communautés de pratique mais ne questionne pas l’impact des principes fondamentaux de l’organisation sur les processus de création, de partage, de mémorisation de la connaissance. Notre travail se situe donc au croisement de deux champs de recherches : la coordination intra-organisationnelle et la connaissance organisationnelle. Suite à une exploration hybride, nous avons formulé notre problématique comme suit : « Comment les membres d’une équipe-projet parviennent-ils à se coordonner et construire de nouvelles connaissances ? ». Trois questionnements sous-jacents apparaissent dans cette problématique : le premier porte sur les pratiques de création de connaissances, le second aborde les pratiques de coordination, et enfin la meilleure compréhension des pratiques de coordination et des pratiques de création de connaissances permet de poser la question de leur relation. Après avoir mené une revue de littérature multidisciplinaire sur la connaissance dans l’organisation afin de rendre compte de la variété des approches, nous présentons dans notre second chapitre de la littérature sur la coordination intra-organisationnelle. Après avoir identifié les défis méthodologiques liés à l’étude de la connaissance dans l’organisation, nous présentons notre méthodologie basée sur les principes de l’étude de cas et les conseils de la théorie de l’acteur-réseau. Nos deux derniers chapitres présentent les données empiriques et les résultats de notre recherche. / Although knowledge management and organizational learning have been on the agenda for several years, some important questions remain unanswered. One of these questions is related to the link between organizing and learning. This thesis aims at understanding the links between practices of knowing and practices of “coordinating” in project teams. We especially study how collective coordination is crafted to deal with the impact of knowing and how the coordinated solutions arising from this coordination practice influence the next knowing practices. With the help of the Actor Network Theory (ANT), a longitudinal and qualitative study, five project teams explore the relation between learning activities and “networking” activities. Based on the findings of these five case studies, our conclusion points towards a view of coordination as a dynamic, socio-material, heterogeneous practices characterized by ongoing learning, transformations, and reconfigurations during “controversies”. Moreover, evidence is provided that the coordination mechanisms impacts the capacity of actors to create and share knowledge.

Page generated in 0.0631 seconds