• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 4
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Ramverk för temperaturstyrning i Matlab : Programmering av DAQ , datalogger,temperaturskåp och spänningsaggregat

Pavlov, Anton, Särnholm, Jonathan January 2016 (has links)
Examensarbetet utfördes på Calmon. Ett Ramverket för instrumenten:DA/AD - Modul, datalogger, klimatkammare och nätaggregat skapades medhjälp av programmet Matlab. Arbetet utfördes med hjälp av programmeringi syfte att kunna genomföra mätningar på föremål i klimatkammaren.Kommandon för styrning av instrumenten implementerades. För att vägledaanvändaren utvecklades en specifikation och ett exempelprogram.
2

Accelerated aging of cellulose-based composites in different climate environments : A project provided by Biofiber Tech Sweden AB

Dungner, Karin, Eskner, Ebba, Holst, Amanda, Petersson, Nina, Pokosta, Maria, Roos, John Eric January 2021 (has links)
This paper reviews the effects of accelerated aging with increased humidity and temperature on cellulose-based composites. The composites consist of a matrix of plastic reinforced with cellulose fibers. The company Biofiber Tech Sweden AB provided four different composites and a conventional polyolefin as reference. The aim was to examine changes in mechanical properties, chemical composition and appearance after aging, as well as variations between materials. Two different climate conditions were tested, 85% RH and <10% RH, both in 90℃. A climate chamber and an oven were used to create the extreme environmental conditions. To analyze the results, tensile testing and FTIR were performed, and color intensity and density were measured. All samples decreased in color intensity throughout aging, and dark irregularities appeared on some of the samples exposed to high humidity, which may be due to fungal formation. The tensile testing showed a general difference between high and low RH and the toughness showed a tendency to decline with aging in high humidity for many samples. The FTIR measurements also did not show any general trend. To improve the study, it would be desirable to age the material for a longer time and at a higher temperature. Overall, more samples and measurements within each characterisation technique would be needed to achieve more reliable results. Nevertheless, this study hopes to be a starting point for further research on the long-term durability of Biofiber Tech’s composites.
3

Towards a virtual climate chamber – A physical experimental study / Mot en virtuell klimatkammare – En fysisk experimentell studie

Arroyo Molina, Javier January 2020 (has links)
This project focuses on experimentally characterizing one of the tools used at Ericsson AB to test product performance, the climatic chamber. By conducting experiments inside the climate chamber and post processing the data obtained, the airflow inside it can be understood and compared to outdoor experimental data. One of the main sections of this work is to prove the hypothesis: The energy potential of the wind outdoors is greater than indoors, which is shown to be true when comparing values for the integral length scales of the flow, at the same mean wind speed. The second main part of this project is to obtain valuable experimental input that will serve to construct a virtual model of the climate chamber. With the conclusions drawn from the experiments, which involve heat transfer, boundary conditions for the numerical model can be established. / Det här projektet fokuserar på att experimentellt karakterisera ett av verktygen som används i Ericsson AB för att testa produktprestanda - klimatkammaren. Genom att utföra experiment inuti klimatkammaren och efterbehandla de erhållna data, kan man få en förståelse för luftflödet inuti kammaren och jämföra resultat med experimentella data från utomhus. Ett av delmomenten i detta arbete bevisar hypotesen: 'Vindens energipotential är större än inomhus', vilket visar sig vara sant när man jämför värden för flödets integrala längdskalor, med samma medelvärde i vindhastighet. Den andra etappen av detta projekt är att erhålla en värdefull experimentell vägledning som kommer att tjäna till att konstruera en virtuell modell av klimatkammaren. Med slutsatserna från experimenten, som innefattar värmeöverföring, kan gränsvillkor för den numeriska modellen fastställas.
4

Robust and Durable Vacuum Insulation Technology for Buildings

Karami, Peyman January 2015 (has links)
Today’s buildings are responsible for 40% of the world’s energy use and also a substantial share of the Global Warming Potential (GWP). In Sweden, about 21% of the energy use can be related to the heat losses through the climatic envelope. The “Million Program” (Swedish: Miljonprogrammet) is a common name for about one million housing units, erected between 1965 and 1974 and many of these buildings suffer from poor energy performance. An important aim of this study was to access the possibilities of using Vacuum Insulation Panels (VIPs) in buildings with emphasis on the use of VIPs for improving the thermal efficiency of the “Million Program” buildings. The VIPs have a thermal resistance of about 8-10 times better than conventional insulations and offer unique opportunities to reduce the thickness of the thermal insulation. This thesis is divided into three main subjects. The first subject aims to investigate new alternative VIP cores that may reduce the market price of VIPs. Three newly developed nanoporous silica were tested using different steady-state and transient methods. A new self-designed device, connected to a Transient Plane Source (TPS) instrument was used to determine the thermal conductivity of granular powders at different gaseous pressure combined with different mechanical loads. The conclusion was that the TPS technique is less suitable for conducting thermal conductivity measurements on low-density nanoporous silica powders. However, deviations in the results are minimal for densities above a limit at which the pure conduction becomes dominant compared to heat transfer by radiation. The second subject of this work was to propose a new and robust VIP mounting system, with minimized thermal bridges, for improving the thermal efficiency of the “Million Program” buildings. On the basis of the parametric analysis and dynamic simulations, a new VIP mounting system was proposed and evaluated through full scale measurements in a climatic chamber. The in situ measurements showed that the suggested new VIP technical solution, consisting of 20mm thick VIPs, can improve the thermal transmittance of the wall, up to a level of 56%. An improved thermal transmittance of the wall at centre-of-panel coordinate of 0.118 to 0.132 W m-2K-1 and a measured centre-of-panel thermal conductivity (λcentre-of-panel) of 7 mW m-1K-1 were reached. Furthermore, this thesis includes a new approach to measure the thermal bridge impacts due to the VIP joints and laminates, through conducting infrared thermography investigations. An effective thermal conductivity of 10.9 mW m-1K-1 was measured. The higher measured centre-of-panel and effective thermal conductivities than the published centre-of-panel thermal conductivity of 4.2 mW m-1K-1 from the VIP manufacturer, suggest that the real thermal performance of VIPs, when are mounted in construction, is comparatively worse than of the measured performance in the laboratory. An effective thermal conductivity of 10.9 mW m-1K-1 will, however, provide an excellent thermal performance to the construction. The third subject of this thesis aims to assess the environmental impacts of production and operation of VIP-insulated buildings, since there is a lack of life cycle analysis of whole buildings with vacuum panels. It was concluded that VIPs have a greater environmental impact than conventional insulation, in all categories except Ozone Depilation Potential. The VIPs have a measurable influence on the total Global Warming Potential and Primary Energy use of the buildings when both production and operation are taken into account. However, the environmental effect of using VIPs is positive when compared to the GWP of a standard building (a reduction of 6%) while the PE is increased by 20%. It was concluded that further promotion of VIPs will benefit from reduced energy use or alternative energy sources in the production of VIP cores while the use of alternative cores and recycling of VIP cores may also help reduce the environmental impact. Also, a sensitivity analysis of this study showed that the choice of VIPs has a significant effect on the environmental impacts, allowing for a reduction of the total PE of a building by 12% and the GWP can be reduced as much as 11% when considering both production and operation of 50 yes. Finally, it’s possible to conclude that the VIPs are very competitive alternative for insulating buildings from the Swedish “Million Program”. Nevertheless, further investigations require for minimizing the measurable environmental impacts that acquired in this LCA study for the VIP-insulated buildings. / Dagens byggnader ansvarar för omkring 40% av världens energianvändning och  står också för en väsentlig del av utsläppen av växthusgaser. I Sverige kan ca 21 % av energianvändningen relateras till förluster genom klimatskalet. Miljonprogrammet är ett namn för omkring en miljon bostäder som byggdes mellan 1965 och 1974, och många av dessa byggnader har en dålig energiprestanda efter dagens mått. Huvudsyftet med denna studie har varit att utforska möjligheterna att använda vakuumisoleringspaneler (VIP:ar) i byggnader med viss fokus på tillämpning i Miljonprogrammets byggnader. Med en värmeledningsförmåga som är ca 8 - 10 gånger bättre än för traditionell isolering erbjuder VIP:arna unika möjligheter till förbättrad termisk prestanda med minimal isolerings tjocklek. Denna avhandling hade tre huvudsyften. Det första var att undersöka nya alternativ för kärnmaterial som bland annat kan reducera kostnaden vid produktion av VIP:ar. Tre nyutvecklade nanoporösa kiselpulver har testats med olika stationära och transienta metoder. En inom projektet utvecklad testbädd som kan anslutas till TPS instrument (Transient Plane Source sensor), har använts för att mäta värmeledningsförmågan hos kärnmaterial för VIP:ar, vid varierande gastryck och olika mekaniska laster. Slutsatsen blev att transienta metoder är mindre lämpliga för utföra mätningar av värmeledningsförmåga för nanoporösa kiselpulver låg densitet. Avvikelsen i resultaten är dock minimal för densiteter ovan en gräns då värmeledningen genom fasta material blir dominerande jämfört med värmeöverföring genom strålning. Det andra syftet har varit att föreslå ett nytt monteringssystem för VIP:ar som kan användas för att förbättra energieffektiviteten i byggnader som är typiska för Miljonprogrammet. Genom parametrisk analys och dynamiska simuleringar har vi kommit fram till ett förslag på ett nytt monteringssystem för VIP:ar som har utvärderats genom fullskaleförsök i klimatkammare. Resultaten från fullskaleförsöken visar att den nya tekniska lösningen förbättrar väggens U-värde med upp till 56 %. En förbättrad värmegenomgångskoefficienten för väggen i mitten av en VIP blev mellan 0.118 till 0,132 W m-2K-1 och värmeledningstalet centre-av-panel 7 mW m-1K-1 uppnåddes. Detta arbete innehåller dessutom en ny metod för att mäta köldbryggor i anslutningar med hjälp av infraröd termografi. En effektiv värmeledningsförmåga för 10.9 mW m-1K-1 uppnåddes. Resultaten tyder även på att den verkliga termiska prestandan av VIP:ar i konstruktioner är något sämre än mätvärden för paneler i laboratorium. En effektiv värmeledningsförmåga av 10.9 mW m-1K-1 ger dock väggkonstruktionen en utmärkt termisk prestanda. Det tredje syftet har varit att bedöma miljöpåverkan av en VIP-isolerad byggnad, från produktion till drift, eftersom en livscykelanalys av hela byggnader som är isolerade med vakuumisoleringspaneler inte har gjorts tidigare. Slutsatsen var att VIP:ar har en större miljöpåverkan än traditionell isolering, i alla kategorier förutom ozonnedbrytande potential. VIP:ar har en mätbar påverkan på de totala utsläppen av växthusgaser och primärenergianvändningen i byggnader när både produktion och drift beaktas. Miljöpåverkan av de använda VIP:arna är dock positiv jämfört med GWP av en standardbyggnad (en minskning med 6 %) medan primärenergianvändningen ökade med 20 %. Slutsatsen var att ytterligare användning av VIP:ar gynnas av reducerad energiförbrukning och alternativa energikällor i produktionen av nanoporösa kiselpulver medan användningen av alternativa kärnmaterial och återvinning av VIP kärnor kan hjälpa till att minska miljöpåverkan. En känslighetsanalys visade att valet av VIP:ar har en betydande inverkan på miljöpåverkan, vilket ger möjlighet att reducera den totala användningen av primärenergi i en byggnad med 12 % och utsläppen av växthusgaser kan vara minska, så mycket som 11 % när det gäller både produktion och drift under 50 år. Avslutningsvis är det möjligt att dra slutsatsen att VIP:ar är ett mycket konkurrenskraftigt alternativ för att isolera byggnader som är typiska för Miljonprogrammet. Dock krävs ytterligare undersökningar för att minimera de mätbara miljöeffekter som förvärvats i denna LCA-studie för VIP-isolerade byggnader. / <p>QC 20151109</p> / Simulations of heat and moisture conditions in a retrofit wall construction with Vacuum Insulation Panels / Textural and thermal conductivity properties of a low density mesoporous silica material / A study of the thermal conductivity of granular silica materials for VIPs at different levels of gaseous pressure and external loads / Evaluation of the thermal conductivity of a new nanoporous silica material for VIPs – trends of thermal conductivity versus density / A comparative study of the environmental impact of Swedish residential buildings with vacuum insulation panels / ETICS with VIPs for improving buildings from the Swedish million unit program “Miljonprogrammet”

Page generated in 0.0393 seconds